Correction: Wang et al. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967
Text Correction
Table Correction
Aorta | Pulmonary Artery | ||
---|---|---|---|
Model | DSC | Model | DSC |
1-AA | 0.97 ± 0.007 | 1-PA | 0.91 ± 0.002 |
2-PA | 0.93 ± 0.002 | ||
3D U-Net | 0.87 ± 0.025 | 3D U-Net | 0.87 ± 0.0004 |
Method | DSC | |
---|---|---|
Aorta | 2016 Jang et al. [25] | 0.95 ± 0.02 |
2009 Išgum et al. [26] | 0.87 ± 0.03 | |
2012 Kurugol et al. [27] | 0.93 ± 0.01 | |
2013 Avila-Montes et al. [28] | 0.88 ± 0.05 | |
2017 Dasgupta et al. [29] | 0.88 ± 0.06 | |
2014 Xie et al. [30] | 0.93 ± 0.01 | |
2015 Kurugol et al. [31]. | 0.92 ± 0.01 | |
2019 Gamechi et al. [32] | 0.95 ± 0.01 | |
2018 Noothout et al. [33] | 0.91 ± 0.04 | |
2021 Lartaud et al. [34] | 0.92 ± 0.02 | |
2020 Haq et al. [35] | 0.75 ≤ DSC ≤ 0.94 | |
2020 Morris et al. [36] | 0.85 ± 0.03 | |
2021 Sedghi Gamechi et al. [37] | 0.96 ± 0.01 | |
Proposed method | 0.97 ± 0.007 | |
Pulmonary artery | 2015 Xie et al. [38] | 0.88 |
2018 López-Linares et al. [39] | 0.89 ± 0.07 | |
2020 Haq et al. [35] | 0.80 ≤ DSC ≤ 0.91 | |
2020 Morris et al. [36] | 0.85 ± 0.03 | |
2021 Sedghi Gamechi et al. [37] | 0.94 ± 0.02 | |
Proposed method | 0.93 ± 0.002 |
Reference
- Wang, H.-J.; Chen, L.-W.; Lee, H.-Y.; Chung, Y.-J.; Lin, Y.-T.; Lee, Y.-C.; Chen, Y.-C.; Chen, C.-M.; Lin, M.-W. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Wang, H.-J.; Chen, L.-W.; Lee, H.-Y.; Chung, Y.-J.; Lin, Y.-T.; Lee, Y.-C.; Chen, Y.-C.; Chen, C.-M.; Lin, M.-W. Correction: Wang et al. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967. Diagnostics 2022, 12, 1867. https://doi.org/10.3390/diagnostics12081867
Wang H-J, Chen L-W, Lee H-Y, Chung Y-J, Lin Y-T, Lee Y-C, Chen Y-C, Chen C-M, Lin M-W. Correction: Wang et al. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967. Diagnostics. 2022; 12(8):1867. https://doi.org/10.3390/diagnostics12081867
Chicago/Turabian StyleWang, Hao-Jen, Li-Wei Chen, Hsin-Ying Lee, Yu-Jung Chung, Yan-Ting Lin, Yi-Chieh Lee, Yi-Chang Chen, Chung-Ming Chen, and Mong-Wei Lin. 2022. "Correction: Wang et al. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967" Diagnostics 12, no. 8: 1867. https://doi.org/10.3390/diagnostics12081867
APA StyleWang, H. -J., Chen, L. -W., Lee, H. -Y., Chung, Y. -J., Lin, Y. -T., Lee, Y. -C., Chen, Y. -C., Chen, C. -M., & Lin, M. -W. (2022). Correction: Wang et al. Automated 3D Segmentation of the Aorta and Pulmonary Artery on Non-Contrast-Enhanced Chest Computed Tomography Images in Lung Cancer Patients. Diagnostics 2022, 12, 967. Diagnostics, 12(8), 1867. https://doi.org/10.3390/diagnostics12081867