Editorial

Taking the Next Step in Personalised Orthopaedic Implantation

by
Maximilian Rudert
Orthopaedic Department, König-Ludwig-Haus, University of Wuerzburg, D-97074 Wuerzburg, Germany
J. Pers. Med. 2022, 12(3), 365; https://doi.org/10.3390/jpm12030365
Submission received: 9 February 2022 / Accepted: 25 February 2022 / Published: 27 February 2022
(This article belongs to the Special Issue Patient-Specific Implants in Musculoskeletal (Orthopedic) Surgery)
Most of the treatments in medicine are patient specific, are they not?
We examine patients, make individual diagnoses and adapt our therapy to the specific case. The more precisely we are in our efforts to record all parameters that could influence our therapy, the more individual our treatment will become for the patient. Machine Learning, Neural Networks, and Big Data management will help us to overcome the endless story of biomedical statistical approaches concerning outcome data in orthopaedics [1]. Hopefully we can find out in the long term who exactly is suitable for which therapy. One problem in orthopaedics is that new treatment approaches, such as patient-specific instruments, are applied equally to all patients without it being possible to demonstrate differences in the treatment result.
Why should we bother with individualization of our implants and techniques, if we adapt our therapy to patients anyway? The more we try to pigeonhole the patient, which is often forced to us by treatment guidelines and classifications we use, the more likely we are not to achieve individual treatment. Looking at the neighbouring field of oncologic treatment, nobody would question that individualization of tumour therapy with personalized instruments like antibodies has led to thriving of this field in terms of success in patient survival and positive responses to alternatives for conventional treatments.
The same seems to happen to the field of orthopaedic surgery although not strikingly obvious because outcome does not equal survival in most of our cases.
Nonetheless, tumour surgery is a good way of looking at things in orthopaedic personalization, but from a different angle. The defects that arise from tumours and their surgical removal are so different that only in rare cases do they not require any adjustment to the standard [2]. This has been the case for decades, but the techniques that are available to us are becoming more and more sophisticated and allow better restorations [3,4,5,6]. The same is actually true for defects in revision arthroplasty and spinal surgery [7,8,9]. Since more and more revisions are re-revisions, the defects and collateral damage become bigger with every episode of loosening and consecutive operation. 3D printing technologies allow for visualization of the defects on templates that can be used to understand our treatment approach. Still, in order to simplify the treatment, we classify the defects, which, firstly, is not easy and, secondly, does not always make sense [10,11]. Again we come into the dilemma of small numbers, very individual anatomical requirements and a multitude of confounders, which make a statistical analysis practically impossible [1]. Furthermore, three-dimensional defects can change during the operative procedure. A lot of experience is therefore necessary in order to anticipate this and either fit bones using resection guides or tolerate inaccuracies where possible.
Modern alignment techniques in primary knee arthroplasty have also adopted the concepts of individualization of the implant position and soft tissue tension to approximate the preoperative situation. In this way, the individual anatomical requirements of the patient are taken into account and the joint is not put into a predicament in which it has never been before. This is intended to increase the outcome and satisfaction [12,13,14]. The use of patient-specific implants in primary endoprosthetics follows a comparable principle. Due to the optimal alignment and size as well as the shape of the implants, the physiological load transfer should be maintained in the entire movement of the joints [15,16,17,18].
Artificial intelligence-based recognition of different types of implants and detection of the region of interest in standard x-rays will help to improve treatment by gathering big data [19,20]. With these large amounts of data, it will be easier to optimize standard situations for the individual patient and his or her specific anatomical requirements [21,22]. Ultimately, however, this information only helps us if we can put it into practice on the patient. Augmented reality and robotic systems will help us to translate the planning [23]. Personally, I strongly believe that these new technologies will bring us further in successful and, above all, adapted therapy for our patients.

Funding

This research received no external funding.

Institutional Review Board Statement

This Editorial did not require ethical approval.

Informed Consent Statement

Not applicable.

Data Availability Statement

See References to the Editorial.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Hewett, T.E.; Webster, K.E. EDITORIAL: The Use of Big Data to Improve Human Health—How Experience from Other Industries Will Shape the Future. Int. J. Sports Phys. Ther. 2021, 16, 29856. [Google Scholar] [CrossRef] [PubMed]
  2. Rudert, M.; Holzapfel, B.M.; Pilge, H.; Rechl, H.; Gradinger, R. Partial pelvic resection (internal hemipelvectomy) and endoprosthetic replacement in periacetabular tumors. Oper. Orthop. Traumatol. 2012, 24, 196–214. [Google Scholar] [CrossRef] [PubMed]
  3. Angelini, A.; Piazza, M.; Pagliarini, E.; Trovarelli, G.; Spertino, A.; Ruggieri, P. The Orthopedic-Vascular Multidisciplinary Approach Improves Patient Safety in Surgery for Musculoskeletal Tumors: A Large-Volume Center Experience. J. Pers. Med. 2021, 11, 462. [Google Scholar] [CrossRef]
  4. Döring, K.; Staats, K.; Puchner, S.; Windhager, R. Patient-Specific Implants for Pelvic Tumor Resections. J. Pers. Med. 2021, 11, 683. [Google Scholar] [CrossRef] [PubMed]
  5. Guder, W.K.; Hardes, J.; Nottrott, M.; Podleska, L.E.; Streitbürger, A. Highly Cancellous Titanium Alloy (TiAl6V4) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results. J. Pers. Med. 2021, 11, 351. [Google Scholar] [CrossRef]
  6. Schulze, M.; Gosheger, G.; Bockholt, S.; De Vaal, M.; Budny, T.; Tönnemann, M.; Pützler, J.; Bövingloh, A.S.; Rischen, R.; Hofbauer, V.; et al. Complex Bone Tumors of the Trunk—The Role of 3D Printing and Navigation in Tumor Orthopedics: A Case Series and Review of the Literature. J. Pers. Med. 2021, 11, 517. [Google Scholar] [CrossRef] [PubMed]
  7. Amin, T.; Parr, W.C.H.; Mobbs, R.J. Opinion Piece: Patient-Specific Implants May Be the Next Big Thing in Spinal Surgery. J. Pers. Med. 2021, 11, 498. [Google Scholar] [CrossRef]
  8. Savov, P.; Tuecking, L.R.; Windhagen, H.; Ettinger, M. Individual Revision Knee Arthroplasty Is a Safe Limb Salvage Procedure. J. Pers. Med. 2021, 11, 572. [Google Scholar] [CrossRef]
  9. von Hertzberg-Boelch, S.P.; Wagenbrenner, M.; Arnholdt, J.; Frenzel, S.; Holzapfel, B.M.; Rudert, M. Custom Made Monoflange Acetabular Components for the Treatment of Paprosky Type III Defects. J. Pers. Med. 2021, 11, 283. [Google Scholar] [CrossRef]
  10. Horas, K.; Arnholdt, J.; Steinert, A.F.; Hoberg, M.; Rudert, M.; Holzapfel, B.M. Acetabular defect classification in times of 3D imaging and patient-specific treatment protocols. Orthopade 2017, 46, 168–178. [Google Scholar] [CrossRef]
  11. Schierjott, R.A.; Hettich, G.; Graichen, H.; Jansson, V.; Rudert, M.; Traina, F.; Weber, P.; Grupp, T.M. Quantitative assessment of acetabular bone defects: A study of 50 computed tomography data sets. PLoS ONE 2019, 14, e0222511. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Huber, K.; Christen, B.; Calliess, S.; Calliess, T. True Kinematic Alignment Is Applicable in 44% of Patients Applying Restrictive Indication Criteria—A Retrospective Analysis of 111 TKA Using Robotic Assistance. J. Pers. Med. 2021, 11, 662. [Google Scholar] [CrossRef] [PubMed]
  13. Nedopil, A.J.; Delman, C.; Howell, S.M.; Hull, M.L. Restoring the Patient’s Pre-Arthritic Posterior Slope Is the Correct Target for Maximizing Internal Tibial Rotation When Implanting a PCL Retaining TKA with Calipered Kinematic Alignment. J. Pers. Med. 2021, 11, 516. [Google Scholar] [CrossRef] [PubMed]
  14. Pumilia, C.A.; Schroeder, L.; Sarpong, N.O.; Martin, G. Patient Satisfaction, Functional Outcomes, and Implant Survivorship in Patients Undergoing Customized Unicompartmental Knee Arthroplasty. J. Pers. Med. 2021, 11, 753. [Google Scholar] [CrossRef] [PubMed]
  15. Grothues, S.A.G.A.; Radermacher, K. Variation of the Three-Dimensional Femoral J-Curve in the Native Knee. J. Pers. Med. 2021, 11, 592. [Google Scholar] [CrossRef]
  16. Moret, C.S.; Schelker, B.L.; Hirschmann, M.T. Clinical and Radiological Outcomes after Knee Arthroplasty with Patient-Specific versus Off-the-Shelf Knee Implants: A Systematic Review. J. Pers. Med. 2021, 11, 590. [Google Scholar] [CrossRef]
  17. Wunderlich, F.; Azad, M.; Westphal, R.; Klonschinski, T.; Belikan, P.; Drees, P.; Eckhard, L. Comparison of Postoperative Coronal Leg Alignment in Customized Individually Made and Conventional Total Knee Arthroplasty. J. Pers. Med. 2021, 11, 549. [Google Scholar] [CrossRef]
  18. Steinert, A.F.; Schroder, L.; Sefrin, L.; Janssen, B.; Arnholdt, J.; Rudert, M. The Impact of Total Knee Replacement with a Customized Cruciate-Retaining Implant Design on Patient-Reported and Functional Outcomes. J. Pers. Med. 2022, 12, 194. [Google Scholar] [CrossRef]
  19. Liu, F.Y.; Chen, C.C.; Cheng, C.T.; Wu, C.T.; Hsu, C.P.; Fu, C.Y.; Chen, S.C.; Liao, C.H.; Lee, M.S. Automatic Hip Detection in Anteroposterior Pelvic Radiographs—A Labelless Practical Framework. J. Pers. Med. 2021, 11, 522. [Google Scholar] [CrossRef]
  20. Sultan, H.; Owais, M.; Park, C.; Mahmood, T.; Haider, A.; Park, K.R. Artificial Intelligence-Based Recognition of Different Types of Shoulder Implants in X-ray Scans Based on Dense Residual Ensemble-Network for Personalized Medicine. J. Pers. Med. 2021, 11, 482. [Google Scholar] [CrossRef]
  21. González-Bravo, C.; Ortega, M.A.; Buján, J.; Torre, B.D.; Barrios, L. Wear Risk Prevention and Reduction in Total Hip Arthroplasty. A Personalized Study Comparing Cement and Cementless Fixation Techniques Employing Finite Element Analysis. J. Pers. Med. 2021, 11, 780. [Google Scholar] [CrossRef] [PubMed]
  22. Habor, J.; Fischer, M.; Tokunaga, K.; Okamoto, M.; Radermacher, K. The Patient-Specific Combined Target Zone for Morpho-Functional Planning of Total Hip Arthroplasty. J. Pers. Med. 2021, 11, 817. [Google Scholar] [CrossRef] [PubMed]
  23. Schlueter-Brust, K.; Henckel, J.; Katinakis, F.; Buken, C.; Opt-Eynde, J.; Pofahl, T.; Rodriguez y Baena, F.; Tatti, F. Augmented-Reality-Assisted K-Wire Placement for Glenoid Component Positioning in Reversed Shoulder Arthroplasty: A Proof-of-Concept Study. J. Pers. Med. 2021, 11, 777. [Google Scholar] [CrossRef] [PubMed]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Rudert, M. Taking the Next Step in Personalised Orthopaedic Implantation. J. Pers. Med. 2022, 12, 365. https://doi.org/10.3390/jpm12030365

AMA Style

Rudert M. Taking the Next Step in Personalised Orthopaedic Implantation. Journal of Personalized Medicine. 2022; 12(3):365. https://doi.org/10.3390/jpm12030365

Chicago/Turabian Style

Rudert, Maximilian. 2022. "Taking the Next Step in Personalised Orthopaedic Implantation" Journal of Personalized Medicine 12, no. 3: 365. https://doi.org/10.3390/jpm12030365

APA Style

Rudert, M. (2022). Taking the Next Step in Personalised Orthopaedic Implantation. Journal of Personalized Medicine, 12(3), 365. https://doi.org/10.3390/jpm12030365

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop