Next Article in Journal
Evaluation of the Ridaquick Rotavirus/Adenovirus Immuno-Chromatographic Assay in Real-Life Situation
Next Article in Special Issue
The Rapid Assessment of Aggregated Wastewater Samples for Genomic Surveillance of SARS-CoV-2 on a City-Wide Scale
Previous Article in Journal
Cytauxzoon sp. and Hepatozoon spp. in Domestic Cats: A Preliminary Study in North-Eastern Italy
Previous Article in Special Issue
Monitoring the Circulation of SARS-CoV-2 Variants by Genomic Analysis of Wastewater in Marseille, South-East France
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Brief Report

Detection and Stability of SARS-CoV-2 Fragments in Wastewater: Impact of Storage Temperature

Department of Microbiology, University of Innsbruck, 6020 Innsbruck, Austria
*
Author to whom correspondence should be addressed.
Pathogens 2021, 10(9), 1215; https://doi.org/10.3390/pathogens10091215
Submission received: 31 July 2021 / Revised: 14 September 2021 / Accepted: 15 September 2021 / Published: 18 September 2021
(This article belongs to the Special Issue SARS-CoV-2 in the Water Environment)

Abstract

:
SARS-CoV-2 wastewater epidemiology suffers from uncertainties concerning sample storage. We show the effect of the storage of wastewater on the detectable SARS-CoV-2 load. Storage at 4 °C for up to 9 days had no significant effect, while storage at −20 °C led to a significant reduction in gene copy numbers.

1. Introduction, Aims and Methods

In the context of the global COVID-19 pandemic, the quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) fragments in wastewater offers the opportunity to monitor the level of infection in large populations, independent of apparent symptoms [1,2]). With the growing number of SARS-CoV-2 wastewater studies, we need comprehensive knowledge on common storage procedures for raw wastewater to generate valid data from sewage surveillance. Temperature, as a central environmental parameter, is a main driver of microbial decay and significantly alters the persistence of viruses in wastewater. Thereby, storage at lower temperatures (<4 °C) increases the persistence of coronaviruses in wastewater [3]. The aim of this investigation was to compare the effect of the most common storage temperatures (≤4 °C) of wastewater samples, +4 °C and −20 °C [4,5], on the detectability of SARS-CoV-2 gene copy numbers.
Therefore, we analyzed 24 h composite samples of raw influent wastewater from the wastewater treatment plant (WWTP) Zirl, Tyrol, Austria (19 April 2020, 30,000 population equivalents (PE)) and the WWTP Siggerwiesen, Salzburg, Austria (4 October 2020, 680,000 PE). The wastewater from the WWTP Zirl was roughly composed of 1/3 industrial and 2/3 domestic wastewater, with a catchment length (main collector) of 50 km. The sample from this plant was taken during dry weather with a mean ambient temperature of 15.2 °C. Meanwhile, the wastewater from the WWTP in Salzburg was mainly composed of domestic wastewater, with a catchment length (main collector) of 140 km. Sampling for this site was conducted during dry weather with a mean ambient temperature of 11.4 °C. The former samples (Zirl) were pasteurized prior to analysis due to uncertainties of the safety status of the wastewater at this time, while the latter (Salzburg) remained unpasteurized. Pasteurization of the wastewater involved an exposure of the samples to 60 °C for 1.5 h prior to sample processing [6]. The investigated storage conditions are summarized in Table 1.
For SARS-CoV-2 RNA extraction, we modified the protocol from Wu et al. [2]. In a first step, larger particles were removed to decrease the amount of non-viral RNA and PCR inhibitors. For this purpose, 40–70 mL of wastewater was transferred to centrifugation tubes and centrifuged at 4500× g for 30 min at 4 °C. To precipitate viral fragments, the resulting supernatant was immediately transferred into a fresh tube containing 10% w/v polyethylene glycol (PEG) 8000 (CarlRoth, Karlsruhe, Germany) and 2.25% w/v NaCl. The Reax2™ overhead shaker (Heidolph, Schwabach, Germany) was used until both additives were dissolved within a few minutes. Subsequently, the samples were centrifuged at 12,000× g for 99 min at 4 °C to obtain a pellet containing the viral fragments. The supernatant was removed in two steps. First, most of the supernatant was carefully decanted, and then, after additional centrifugation at 12,000× g for 5 min, a pipette was used to remove the remaining fluid.
Following the precipitation of the viral fragments, pellets from the Zirl samples were resuspended with 800 µL TRIzol® (Invitrogen, Waltham, MA, USA), and TRIzol®-chloroform extraction was performed. For the Salzburg samples, we substituted hazardous TRIzol® with 800 µL lysis buffer (Monarch™ total RNA Miniprep Kit, NewEnglandBiolabs, Ipswich, MA, USA). The aqueous, pale phase from TRIzol®-chloroform extraction or the pellet resuspended in lysis buffer was purified according to the manufacturer protocol of the Monarch™ total RNA Miniprep Kit with non-enzymatic gDNA removal. RNA was eluted in 40 µL RNase-free water.
RNA concentrations of the templates were quantified via a Nanodrop, and extracts with RNA concentrations above 200 ng µL−1 were diluted as needed. RNA copy numbers were determined using the N1 primers/probe according to the CDC protocol [7] targeting the nucleocapsid gene of SARS-CoV-2. RT-qPCR reactions contained the following per 20 µL: 10 µL Luna Universal Probe One-Step Reaction Mix (2X) from NEB, 1 µL Luna WarmStart® RT Enzyme Mix (20×) from NEB, 0.8 µL primer (final concentration 0.4 µM), 0.4 µL probe (final concentration 0.2 µM), 2 µL PCR-grade water, and 5 µL template. Analyses were conducted on a RotorGene cycler (Qiagen, Hilden, Germany). After an initial reverse transcription at 55 °C for 10 min, followed by 95 °C for 1 min of denaturation, 45 cycles of 95 °C for 10 sec and 60 °C for 40 sec were performed. To calculate copy numbers, a plasmid standard containing the N gene of SARS-CoV-2 (2019-nCoV_N_Positive Control, IDT, Leuven, Belgium) was used. All variants were processed in parallel (n ≥ 3) and were tested for significant differences against day 0 using the Mann–Whitney U Test (α = 0.05) in the software package Past 4.03 [8].
Within all samples stored at 4 °C, variation coefficients spanned from 2% to 51%, with a median of 37%. This variance inhomogeneity may be explained by the heterogeneity of the influent wastewater and by the accumulation of inaccuracies during the multi-step extraction protocol. Large variance and inhomogeneity were reported earlier by Wu et al. [9] and seemed to be independent of the method of viral fragment concentration as reported by Ahmed et al. [2]. Pasteurization of the former samples (Zirl) may have had an impact on the recovery and analysis of SARS-CoV-2 from wastewater. Pecson et al. [10] showed that pasteurization may lead to a slight increase in the recovery of SARS-CoV-2 fragments. Nevertheless, samples were pasteurized right before sample processing, and storage conditions were equal for all variants.

2. Results and Discussion

Short-term storage of wastewater for up to 9 days at 4 °C had no significant effect on the number of detectable SARS-CoV-2 fragments (Figure 1 and Figure 2). These findings are in accordance with earlier studies on enveloped viruses [11,12]. In contrast to our storage experiments, Ahmed et al. [3] chose a spike-in approach, using high loads of gamma-irradiated SARS-CoV-2 virions (approximately 6.7 × 105 gc mL−1), and stated a decay rate of approximately 8% per day at 4 °C.
Freezing–thawing of samples led to a significant loss of the signal. A possible reason is that the freeze–thaw cycle disrupts cells, which is also reflected in the increased RNA concentration in the frozen samples (Figure 1 and Figure 2). The release of cell contents possibly includes also proteases and RNases, which may impair the subsequent SARS-CoV-2 detection.
In conclusion, we recommend storing wastewater samples for SARS-CoV-2 analysis at 4 °C upon analysis and not freezing them.

Author Contributions

Conceptualization, R.M., N.L. and A.O.W.; methodology, R.M. and N.L.; software, M.M.; validation, E.P. and R.M.; formal analysis, R.M. and E.P.; investigation, R.M. and N.L.; resources, H.I.; data curation, R.M. and M.M.; writing—original draft preparation, R.M.; writing—review and editing, R.M., N.L., A.O.W. and H.I.; visualization, R.M.; supervision, A.O.W.; project administration, H.I.; funding acquisition, H.I. All authors have read and agreed to the published version of the manuscript.

Funding

This work was financially supported by the “Förderkreis 1669–Wissenschaft Gesellschaft” and by the Austrian Federal Ministry of Education, Science and Research.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Acknowledgments

We would like to thank the WWTPs Zirl and Siggerwiesen very much for their collaboration and for supplying the samples.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Medema, G.; Heijnen, L.; Elsinga, G.; Italiaander, R.; Brouwer, A. Presence of SARS-Coronavirus-2 RNA in Sewage and Correlation with Reported COVID-19 Prevalence in the Early Stage of the Epidemic in The Netherlands. Environ. Sci. Technol. Lett. 2020, 7, 511–516. [Google Scholar] [CrossRef]
  2. Wu, F.; Zhang, J.; Xiao, A.; Gu, X.; Lee, W.L.; Armas, F.; Kauffman, K.; Hanage, W.; Matus, M.; Ghaeli, N.; et al. SARS-CoV-2 Titers in wastewater are higher than expected from clinically confirmed cases. MSystems 2020, 5, e00614-20. [Google Scholar] [CrossRef] [PubMed]
  3. Ahmed, W.; Bertsch, P.M.; Bibby, K.; Haramoto, E.; Hewitt, J.; Huygens, F.; Gyawali, P.; Korajkic, A.; Riddell, S.; Sherchan, S.P.; et al. Decay of SARS-CoV-2 and surrogate murine hepatitis virus RNA in untreated wastewater to inform application in wastewater-based epidemiology. Environ. Res. 2020, 191, 110092. [Google Scholar] [CrossRef] [PubMed]
  4. Ahmed, W.; Bivins, A.; Bertsch, P.M.; Bibby, K.; Choi, P.M.; Farkas, K.; Gyawali, P.; Hamilton, K.A.; Haramoto, E.; Kitajima, M.; et al. Surveillance of SARS-CoV-2 RNA in wastewater: Methods optimisation and quality control are crucial for generating reliable public health information. Curr. Opin. Environ. Sci. Health 2020. [Google Scholar] [CrossRef] [PubMed]
  5. Michael-Kordatou, I.; Karaolia, P.; Fatta-Kassinos, D. Sewage analysis as a tool for the COVID-19 pandemic response and management: The urgent need for optimised protocols for SARS-CoV-2 detection and quantification. J. Environ. Chem. Eng. 2020, 8, 104306. [Google Scholar] [CrossRef] [PubMed]
  6. Darnell, M.E.R.; Subbarao, K.; Feinstone, S.M.; Taylor, D.R. Inactivation of the coronavirus that induces severe acute respiratory syndrome, SARS-CoV. J. Virol. Meth. 2004, 121, 85–91. [Google Scholar] [CrossRef] [PubMed]
  7. CDC. 2019-Novel Coronavirus (2019-nCoV) Real-Time rRT-PCR Panel Primers and Probes. 2020. Available online: https://www.cdc.gov/coronavirus/2019-ncov/lab/rt-pcr-panel-primer-probes.html (accessed on 1 April 2020).
  8. Hammer, Ø.; Harper, D.A.T.; Ryan, P.D. Past: Paleontological Statistics Software Package for Education and Data Analysis. Palaeont. Electron. 2001, 4, 9. [Google Scholar]
  9. Wu, F.; Xiao, A.; Zhang, J.; Moniz, K.; Endo, N.; Armas, F.; Bonneau, R.; Brown, M.A.; Bushman, M.; Chai, P.R.; et al. SARS-CoV-2 titers in wastewater foreshadow dynamics and clinical presentation of new COVID-19 cases. MedRxiv 2020. [Google Scholar] [CrossRef]
  10. Pecson, B.M.; Darby, E.; Haas, C.N.; Amha, Y.M.; Bartolo, M.; Danielson, R.; Dearborn, Y.; Giovanni, G.D.; Ferguson, C.; Fevig, S.; et al. Reproducibility and sensitivity of 36 methods to quantify the SARS-CoV-2 genetic signal in raw wastewater: Findings from an interlaboratory methods evaluation in the U.S. Environ. Sci. Water Res. Technol. 2021, 7, 504–520. [Google Scholar] [CrossRef] [PubMed]
  11. Casanova, L.; Rutala, W.A.; Weber, D.J.; Sobsey, M.D. Survival of surrogate coronaviruses in water. Water Res. 2009, 43, 1893–1898. [Google Scholar] [CrossRef] [PubMed]
  12. Muirhead, A.; Zhu, K.; Brown, J.; Basu, M.; Brinton, M.A.; Costa, F.; Hayat, M.J.; Stauber, C.E. Zika Virus RNA Persistence in Sewage. Environ. Sci. Technol. Lett. 2020, 7, 659–664. [Google Scholar] [CrossRef]
Figure 1. N gene copy numbers and RNA concentrations detected in wastewater from a WWTP in Salzburg after 0, 2, 7, and 9 days of storage at 4 °C as well as after freezing (n = 4, median, box: min-max).
Figure 1. N gene copy numbers and RNA concentrations detected in wastewater from a WWTP in Salzburg after 0, 2, 7, and 9 days of storage at 4 °C as well as after freezing (n = 4, median, box: min-max).
Pathogens 10 01215 g001
Figure 2. N gene copy numbers and RNA concentrations detected in wastewater from a WWTP in Tyrol after 0, 1, 3, and 7 days of storage at 4 °C as well as after freezing (n = 3, median, box: min-max).
Figure 2. N gene copy numbers and RNA concentrations detected in wastewater from a WWTP in Tyrol after 0, 1, 3, and 7 days of storage at 4 °C as well as after freezing (n = 3, median, box: min-max).
Pathogens 10 01215 g002
Table 1. Experimental design.
Table 1. Experimental design.
WWTPSampling DatePasteurizationStorage at −18 °CStorage at 4 °C
Zirl, Tyrol19 April 2020yes2 days0, 1, 3, 7 days
Siggerwiesen, Salzburg4 October 2020no3 days0, 2, 7, 9 days
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Markt, R.; Mayr, M.; Peer, E.; Wagner, A.O.; Lackner, N.; Insam, H. Detection and Stability of SARS-CoV-2 Fragments in Wastewater: Impact of Storage Temperature. Pathogens 2021, 10, 1215. https://doi.org/10.3390/pathogens10091215

AMA Style

Markt R, Mayr M, Peer E, Wagner AO, Lackner N, Insam H. Detection and Stability of SARS-CoV-2 Fragments in Wastewater: Impact of Storage Temperature. Pathogens. 2021; 10(9):1215. https://doi.org/10.3390/pathogens10091215

Chicago/Turabian Style

Markt, Rudolf, Markus Mayr, Evelyn Peer, Andreas O. Wagner, Nina Lackner, and Heribert Insam. 2021. "Detection and Stability of SARS-CoV-2 Fragments in Wastewater: Impact of Storage Temperature" Pathogens 10, no. 9: 1215. https://doi.org/10.3390/pathogens10091215

APA Style

Markt, R., Mayr, M., Peer, E., Wagner, A. O., Lackner, N., & Insam, H. (2021). Detection and Stability of SARS-CoV-2 Fragments in Wastewater: Impact of Storage Temperature. Pathogens, 10(9), 1215. https://doi.org/10.3390/pathogens10091215

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop