Next Article in Journal
Identification of a Novel Idiopathic Epilepsy Risk Locus and a Variant in the CCDC85A Gene in the Dutch Partridge Dog
Next Article in Special Issue
Ultrasound Morphometry and Mean Echogenicity of Digital Flexor Tendons, Suspensory Ligament, and Accessory Ligament of Digital Deep Flexor Tendon in Gaited Horses
Previous Article in Journal
Integrated Single-Trait and Multi-Trait GWASs Reveal the Genetic Architecture of Internal Organ Weight in Pigs
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

M-Mode Echocardiographic Measurements of Interventricular Septum, Left Ventricular Internal Diameter, and Left Ventricular Free-Wall Thickness in Normal Horses—A Meta-Analytical Study

1
Department of Clinical Sciences, College of Veterinary Medicine, King Faisal University, Al-Ahsa 31982, Saudi Arabia
2
Department of Surgery, Faculty of Veterinary Medicine, Kafrelsheikh University, Kafrelsheikh 33511, Egypt
3
Department of Biomedical Sciences, College of Veterinary Medicine, King Faisal University, Al-Ahsa 31982, Saudi Arabia
4
Department of Pharmacology, Faculty of Veterinary Medicine, Kafrelsheikh University, Kafrelsheikh 33511, Egypt
5
Department of Anatomy, College of Veterinary Medicine, King Faisal University, Al-Ahsa 31982, Saudi Arabia
6
Department of Internal Medicine, Infectious Diseases and Fish Diseases, Faculty of Veterinary Medicine, Mansoura University, Manosura 35516, Egypt
*
Authors to whom correspondence should be addressed.
Animals 2023, 13(5), 809; https://doi.org/10.3390/ani13050809
Submission received: 22 November 2022 / Revised: 11 February 2023 / Accepted: 15 February 2023 / Published: 23 February 2023
(This article belongs to the Special Issue Ultrasonography in Equine Medicine)

Abstract

:

Simple Summary

The current meta-analysis offers a general perspective on the echocardiographic measurements of heart dimensions in sound Thoroughbred and Standardbred horses. The study was performed according to the guidelines of PRISMA. The echocardiographic findings varied from one study to the next due to the fact that there were multiple investigations. The meta-analysis indicates variations in results among different studies. This result should be considered when evaluating a horse for heart disease and each case should be evaluated independently.

Abstract

The purpose of this study was to provide a systematic meta-analysis on echocardiographic measurements in normal Thoroughbred and Standardbred horses. The current systematic meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). All the available published papers on the reference values of echocardiographic assessment via M-mode echocardiography were searched, and fifteen studies were finally selected for analysis. In both fixed and random effect, the confidence interval (CI) for the interventricular septum (IVS) was 2.8–3.1 and 4.7–7.5; for the left ventricular free-wall (LVFW) thickness, it was 2.9–3.2 and 4.2–6.7; and for the left ventricular internal diameter (LVID), it was −5.0–4.6 and −10.0–−6.7, respectively. For IVS, the Q statistic, I-squared, and tau-squared were 925.3, 98.1, and 7.9, respectively. Similarly, for LVFW, all the effects were on the positive side of zero, with a range of 1.3–68.1. The CI indicated a significant variation among the studies (fixed, 2.9–3.2; random, 4.2–6.7). The z-values of LVFW for fixed and random effects were, respectively, 41.1 (p < 0.001) and 8.5 (p < 0.001). However, the Q statistic was 886.6 (p < 0.001). Moreover, the I-squared was 98.08, and the tau-squared was 6.6. By contrast, the effects of LVID fell on the negative side of zero, (2.8–83.9). The present meta-analysis provides an overview of the echocardiographic measurements of cardiac diameters in healthy Thoroughbred and Standardbred horses. The meta-analysis indicates variations in results among different studies. This result should be considered when evaluating a horse for heart disease and each case should be evaluated independently.

1. Introduction

Echocardiography is a non-invasive procedure that permits the thorough visualization of cardiac chambers as well as their valves and is helpful in the diagnosis and monitoring of animals with suspected or known heart diseases [1]. Echocardiography provides an evaluation of cardiac output, ejection fraction, diastolic function, and fractional shortening [2]. Moreover, it helps to diagnose cardiac diseases, including atrial septal defects, atrioventricular valve stenosis, aortocardiac fistula and hypertrophic cardiomyopathy, and dilated cardiomyopathy [1,3,4].
M-mode echocardiography is used to obtain high-resolution real-time images of cardiac structures [5,6]. It was the first applicable procedure in horses in the late 1970s [7]. Via M-mode echocardiography, the heart chambers, myocardium, valves, pericardium, and great vessels can be easily visualized [8]. M-mode echocardiography has a high sampling rate when compared with 2D-mode and is superior to real-time images in recording subtle changes in the wall and valve motion and is used for the assessment of the size and function of the left ventricle [5]. In-depth reports on M-mode echocardiography in foals, adult horses, and ponies, including measures of heart size, have been provided [9,10,11,12,13,14,15].
Echocardiography’s ability to measure cardiac diameters is widely regarded as a pivotal technique for assessing the severity and prognosis of cardiac disease and the heart’s reaction to physical exertion [16]. Indeed, in horses, the effects of training [17,18], growth [12,19], body weight [19,20,21,22], animal’s gender [11,16,18,23], and animal breed [20,24] on echocardiographic measurements have been described. However, these effects have never been statistically tested. The majority of investigations to examine the intra- and inter-observer repeatability of equine echocardiographic measures were conducted in horses and donkeys [2,25].
Meta-analysis is defined as a quantitative, epidemiological study design used to systematically assess previous research studies to reach conclusions about that body of research [26]. Meta-analyses have attracted much attention from the general public and have become increasingly popular in the biomedical field [27]. The medical and statistical literature contains numerous references to the theory and correct methodology for meta-analysis [28].In addition to obtaining definitive conclusions regarding the research topic at hand, meta-analysis estimates the real effect of a treatment or exposure on a certain outcome by combining data from many trials [27,29]. Subsequently, a consolidated and quantitative review of such large and complex studies is obtained [26]. The examination of variability or heterogeneity in the results obtained by previous studies is also a critical outcome of meta-analyses [30].
Meta-analysis assists to overcome the lack of the statistical capacity to reach concrete conclusions in independent studies, as well as the failure to appropriately analyze the differences in the risk of extremely uncommon adverse events in large-scale studies [31]. When the results of several studies, even if they are incompatible with one another, are systematically integrated, the real magnitude of the effect may be more precisely defined [32].
In fact, extensive meta-analysis studies on echocardiographic measurements in humans have been carried out [33]. However, in the veterinary field, limited studies were carried out on canine echocardiography [34]. According to the authors’ knowledge, there are no available studies in the literature on the meta-analysis of echocardiographic parameters in horses. Consequently, the objective of this systematic review was to present a meta-analysis on the measurements of the interventricular septum (IVS), the left ventricular free-wall (LVFW) thickness, and the left ventricular internal diameter (LVID), in healthy Standardbred and Thoroughbred horses.

2. Materials and Methods

2.1. Selected Studies

The reference values for the echocardiographic evaluation of heart diameters in Thoroughbred and Standardbred horses were generated in this meta-analysis.

2.2. Types of Reference Individuals

None of the horses investigated had any cardiac abnormalities or pathological conditions that might affect cardiac function or size. Any level of sample size was acceptable.

2.3. Inclusion and Exclusion Criteria

2.3.1. Inclusion Criteria

-
For papers written in a foreign language, the availability of the English version of the reports;
-
Measurements were obtained via M-mode echocardiography;
-
Measurements were obtained via the right parasternal short-axis view (RPSAX);
-
Measurements were obtained at end-systole and end-diastole.

2.3.2. Exclusion Criteria

-
Measurements taken from other different breeds;
-
Methods of examination other than RPSAXs;
-
Incomplete parameters of cardiac diameters;
-
Non-English published papers.

2.4. Search Strategy and Selection of Studies

The goal was to find all published publications dating back to the early days of regular echocardiography. The authors searched the PubMed, Ovid, Sage, BESCO, CAB, Scopus, and ISI web of knowledge databases from the beginning of time until July 2018 using the search phrases ECHOCARDIOGRAPHY (title/abstract) AND (“NORMAL VALUES”) (title/abstract) OR (“REFERENCE VALUES”) (title/abstract). This method was supplemented by citation evaluation, Google Scholar searches, expert suggestions, and hand-searching. Using EndNote, a reference application, we integrated the database results (version X7; Thomson Reuters). The articles included in this study are shown in Figure 1.

2.5. Data Extraction and Analysis

The following information was extracted using a data extraction form: the study’s year, sample size, and provided summary statistics (i.e., the standard difference in means, standard error, variance, Hedges’s g, and the difference in means), types of breed, and the measurements and methods of cardiac diameters during the cardiac cycle (Table 1).

2.6. Quality Assurance

The current systematic meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [40]. All the available published papers on the reference values of the echocardiographic assessment of cardiac diameters in normal healthy Thoroughbred and Standardbred horses were included, to minimize publication bias.

2.7. Statistical Analysis

For statistical analyses, a commercial software program for meta-analysis was used (comprehensive meta-analysis version 2, USA). Descriptive statistics were applied to present the mean values of echocardiographic parameters in the finally selected papers. The variables meta-analysis used were fixed and random-effect models, 95% confidence intervals, effect size, heterogeneity, and weight. The effect size was determined using a standardized Z statistic and p-value [41]. Heterogeneity was assessed using Cochrane’s Q test with a significant value of p < 0.05, and the I2 statistic was used to define the % of true heterogeneity among the analyses. The I2 statistic was used to estimate the degree of heterogeneity, which refers to the total variation depending on the Q statistic and the number of trials (K). In fact, a negative value of I2 was considered equal to zero, and consequently, the I2 statistic ranged between 0% and 100%, and a value equal to or more than 50% was considered heterogeneous [42]. With values of 25%, 50%, and 75%, low, moderate, and high degrees of heterogeneity were identified, respectively [30]. Study weight was calculated as the base inverse square of the standard error of the effect of each trial. Forest plots were used to present the means and their confidence intervals in a graphic manner, and heterogeneous degrees were explored. Meta-regression was performed to study the effect of age, gender, and body weight on the echocardiographic measurements, and a result with a p-value < 0.05 was considered significant.

3. Results

The final model of meta-analysis for the measurement of IVS, LVID, and LVFW in healthy Standardbred and Thoroughbred horses is presented in Table 2 and Figure 2, Figure 3 and Figure 4.
The results revealed that all the effects of IVS were on the positive side of zero, in the range of 1.36–66.08. The 95% confidence interval (CI) supported this finding in both fixed and random effects, indicating significant variations among the studies (fixed, CI 95%: 2.8–3.1; random, CI 95%: 4.7–7.5 (Table 2, Figure 2). For the relative weight, the study by Al-Haidar et al. (2013) was assigned a relative weight of 0.01%, while that of Leadon et al. (1991) was assigned a relative weight of 57.97%. In our study, the test of the null hypothesis (two-tailed) showed that the z-values of IVS for fixed and random effects were 39.5 (p < 0.001) and 8.7 (p < 0.001), respectively. For heterogenicity, the Q statistic was 925.3, compared with the expected value of 17 (p < 0.001); the I-squared was 98.1, and the tau-squared was 7.9.
On the other side, all the effects of LVID fell on the negative side of zero, in the range of 2.8–83.9. The 95% CI indicated a significant variation among the studies (fixed, 95% CI 5.08 to 4.6; random, 95% CI 10.08–6.7) (Table 2, Figure 3). Under a fixed effect, the point estimate was −4.8, with a standard error of 0.102. By contrast, under a random effect, the point estimate was −8.3, with a standard error of 0.8. For the relative weight, the study by Al-Haidar et al. (2013) was assigned a relative weight of 0.01%, while that of Leadon et al. (1991) was assigned a relative weight of 51.57%. For the test of the null hypothesis (two-tailed), the z-values for the fixed and random effects were 48.09 (p < 0.001) and 9.7 (p < 0.001), respectively. For heterogenicity, the Q statistic was 844.949 (p < 0.001), and the I-squared and tau-squared values were 97.988 and 11.977, respectively.
Similarly, for LVFW, all the effects were on the positive side of zero, in the range of 1.350 to 68.176. The 95% CI indicated a significant variation among studies (Table 2, Figure 4). Under a fixed effect, the point estimate was 3.1, with a standard error of 0.07 and a 95% CI of 2.93.2. However, under a random effect, the point estimate was 5.4, with a standard error of 0.6 and a 95% CI of 4.2 to 6.7. For the test of the null hypothesis (two-tailed), the z-values for the fixed and random effects were 41.114 (p < 0.001) and 8.545 (p < 0.001), respectively. However, for heterogenicity, the Q statistic of LVFW was 886.648, compared with the expected value of 17 (p < 0.001), while the I-squared was 98.083, and the tau-squared was 6.680.

4. Discussion

In the present study, we conducted a systematic meta-analysis on the echocardiographic measurements of IVS, LVID, and LVFW, in Thoroughbred and Standardbred horses. For IVS, LVID, and LVFW, considering both types of effects (fixed and random), there was a variation among the results of the measurements. It is speculated that the controversy about the reliability of studies is due to the precision of the technique used. This finding is consistent with that previously reported [43]. In the present results, there was a non-significant effect of body weight, age, breed, and gender on the measurements. The combined effect of such factors with other unknown variables may be the cause of variations in measurements. It has also been reported that training and growth can affect echocardiographic measurements [17,18].
For IVS, the confidence interval (CI) of 95% in the study of Al-Haidar et al. [2] was about six times as wide as that in another study by Al-Haidar et al. [35], and the values in eleven other studies fell somewhere in between. Al-Haidar et al. [2] showed that the effect of size was reduced to 2.9 in the fixed-effect model, in which the weights dominated in the current study. The overall effect estimate was accurate, with a tiny within-study error for IVS of 0.07. Currently, just 15 research were analyzed, and their impact sizes varied widely. Our standard error of IVS (0.6) was almost six times the fixed-effect value, indicating that our estimate of the mean impact was not exact. It has been reported that a within-study error is an accurate indicator to assess the mean impact [44].
For LVID, the 95% CI reported by Pipers and Hamlin [7] was about three times as wide as the one recorded by Brown et al. [22], while the values in fifteen other studies fell somewhere in between. Interestingly, the study of Brown et al. [22] had a low effect size. Under a fixed effect, the effect size decreased to 4.8%. However, the 95% CI was 8.3 when random factors were considered. The LVID research had a slight within-study error due to a large number of individuals (15 in each group) (0.1). The standard error for the mean effect was 0.864, which was about three times the standard error for the fixed-effect value, indicating that the mean impact was not particularly precise.
For LVFW, the 95% CI stated by Slater and Herrtage [20] was about three times as wide as the one stated by Al-Haidar et al. [35]. Under the fixed-effect model, the effect size was reduced to 3.144, but it was 5.498 under the random-effect model. The within-study error for LVFW was small (0.07), indicating an accurate estimate of the combined effect. The mean effect sizes varied, where the standard error was 0.643, which was about three times that of the fixed-effect value.
The confidence interval (CI) of 95% for IVS supported these findings in both fixed and random effects, indicating a significant variation among the studies (fixed, 95% CI 2.8–3.1; random, 95% CI 4.7–7.5) and for LVID (fixed, 5.0 to 4.6; random, −10.0–−6.7) and for LVFW (fixed, 2.9–3.2; random, 4.2–6.7). The measurements of the three variables varied among the studies, which may be due to the wide range of horse breeds and ages in most of the studies.
The relative weight is the average of weights as a proportion of total weights, with all relative weights added up to 100% [45]. For IVS, the study by Leadon et al. (22) was given 58% of the weight under the fixed-effect model but only 6% of the weight under the random-effect model despite having a high sample size (n = 600 for each group). Under the fixed-effect paradigm, we assumed that all the studies and the existing study had the same value. A more accurate estimate was found in the study by Leadon et al. [23]. On the other hand, it was assumed that each study estimated a different impact in the random-effect model. The same study provided an accurate estimate of the IVS population, but because it was just one among several, we did not want it to dominate the analysis. As a result, we gave it 6% of the relative weight, which was more than the weight we gave it under fixed effects but lower than previous studies.
For LVID, the study of Leadon et al. (1991) [23] was assigned 52% of the weight under the fixed-effect model but only 6% of the weight under the random-effect model. The above-mentioned study provided an accurate estimate of its population. In our study, we assigned it 6% of the weight. This was more than the values in the other studies but not as dominant a weight as that we gave it under fixed effects. Similarly, for LVFW, the study by Leadon et al. [23] was assigned 46% of the weight under the fixed-effect model but only 6% of the weight under the random-effect model.
Regarding heterogeneity, under both fixed (common) and random (true) effects, the null hypothesis was that the effect would be zero. The null hypothesis was tested using the z-value, which was computed as Hedges’s g/standard error (G/SE) for the corresponding model [46]. In our study, the z-values for the fixed and random effects of IVS were 39.519 (p < 0.001) and 8.793 (p < 0.001), and for LVID, they were 48.090 (p < 0.001) and 9.719 (p < 0.001). For LVFW, the z-values were 41.114 (p < 0.001) and 8.545 (p < 0.001), respectively.
In the present study, the Q statistic for IVS was 925.307, while for LVID, it was 844.949, and for LVFW, it was 886.648, compared with the expected value of 17 (p < 0.001). The Q statistic implied the observed dispersion, whereas the null hypothesis for heterogeneity argued that the studies assigned a common effect size. Therefore, the degrees of freedom were assumed to be equal to the Q statistic [47].
While the Q statistic is used to test the null hypothesis that there is no dispersion across effect sizes, the I-squared and tau-squared are valuable parameters to evaluate [48]. The I-squared of IVS was 98.163, while that of LVID was 97.988, and that of LVFW was 98.083, indicating that the real variations in effect sizes accounted for 90% of the apparent variance among the studies. On the basis of random error, only 10% of the observed variation may be predicted. However, the tau-squared of IVS was 7.905; that of LVID was 11.977; and that of LVFW was 6.680. This is the variance “between studies” that was used in computing the weights.
Because they are derived using fixed-effect weights, the Q statistic and tau-squared are normally given in fixed-effect models but not in random-effect models. Q statistic solves the question of whether the fixed-effect model fits the data in the fixed-effect study (i.e., whether it is sufficient to suppose that the tau-squared is really zero). To give weights, however, the tau-squared is really set to zero [30]. Unfortunately, the Q test is only employed in meta-analysts to inform on the presence or absence of heterogeneity; it does not reveal the degree of such heterogeneity. In a meta-analysis investigation, the I-squared index has been proposed to measure the degree of heterogeneity [49]. In our study, the statistical differences between the studies may be attributed to the sample size, body weight, breed, and gender.
The limitations of the present investigation should be acknowledged. First, like other meta-analyses reporting reference values, remarkable heterogeneity was an innate limitation, although we attempted to explore the source of heterogeneity and define reference values with detailed information. Second, not all variables were comparable, as only IVS, LVID, and LVFW were presented via M-mode echocardiography. These variables were selected for investigation in all the studies. However, in other meta-analytical studies in humans and animals, a wide range of cardiac diameters was included [33,50,51]. Moreover, to minimize the limitations in our study, the checklist of PRISMA, which is considered a standard technique, was used.

5. Conclusions

This is the first meta-analysis that summarizes the results of the currently available studies looking at the identification of normative values for IVS, LVID, and LVFW, as assessed via M-mode echocardiography in horses. All the variables of this meta-analysis indicated variations in the results among the different studies. This result should be considered when evaluating a horse for heart disease, and each case should be evaluated independently.

Author Contributions

Conceptualization, M.M., M.K., H.B. and S.E.-k.; methodology, M.M. and S.E.-k.; software, A.F., H.I. and M.E.-A.; validation, M.M., M.K., H.B., A.F., H.I. and S.E.-k.; formal analysis, M.E.-A.; investigation, A.F., H.I., M.E.-A., Y.A. and S.E.-k.; resources, M.M.; data curation, S.E.-k.; writing—original draft preparation, M.M., M.K., H.B., A.F., H.I. and S.E.-k.; writing—review and editing, M.M., M.K., K.M.A., A.F., H.I. and S.E.-k.; visualization, M.M.; supervision, K.M.A.; project administration, M.M., K.M.A., H.I. and S.E.-k.; funding acquisition, M.M. All authors have read and agreed to the published version of the manuscript.

Funding

This project was funded by the Deputyship for Research and Innovation, Ministry of Education, Saudi Arabia, through project number INST093.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors extend their appreciation to the Deputyship for Research and Innovation Ministry of Education in Saudi Arabia, for funding this research work (project number INST093).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Reef, V.B.; Whittier, M.; Allam, L.G. Echocardiography. Clin. Tech. Equine Pract. 2004, 3, 274–283. [Google Scholar] [CrossRef]
  2. Al Haidar, A.; Farnir, F.; Deleuze, S.; Sandersen, C.; Amory, H. Comparison of the Repeatability of Echocardiographic Measurements from Different Modes and Views in Horses of Various Breeds and Sizes. J. Equine Vet. Sci. 2010, 30, 287–297. [Google Scholar] [CrossRef]
  3. Gazi, M.; Makhdoomi, D.; Abbas, H.; Parrah, J.; Ganai, A.; Dar, S.; Moulvi, B. Advances of Echocardiography in Equines Practice-A Review. J. Vet. Sci. Technol. 2015, 6, 2. [Google Scholar]
  4. Deacon, L.J.; Navas de Solis, C.; Richardson, D.W.; Polkes, A.; Reef, V.B. Closure of an Aortocardiac Fistula in a Horse. CASE 2022, 6, 43–48. [Google Scholar] [CrossRef]
  5. Reef, V. Echocardiographic findings in horses with congenital cardiac disease. Compend. Contin. Educ. Pract. Vet. 1991, 13, 109–117. [Google Scholar]
  6. Patteson, M.W.; Gibbs, C.; Wotton, P.R.; Cripps, P.J. Echocardiographic measurements of cardiac dimensions and indices of cardiac function in normal adult thoroughbred horses. Equine Vet. J. Suppl. 1995, 19, 18–27. [Google Scholar] [CrossRef]
  7. Pipers, F.S.; Hamlin, R.L. Echocardiography in the horse. J. Am. Vet. Med. Assoc. 1977, 170, 815–819. [Google Scholar]
  8. dos Santos Michima, L.E.; Latorre, S.M.; de Andrade, A.F.C.; Fernandes, W.R. B-mode and M-mode echocardiography of endurance horses raised in São Paulo State, Brazil. J. Equine Vet. Sci. 2004, 24, 451–457. [Google Scholar] [CrossRef]
  9. Bayly, W.M.; Reed, S.M.; Leathers, C.W.; Brown, C.M.; Traub, J.L.; Paradis, M.R.; Palmer, G.H. Multiple congenital heart anomalies in five Arabian foals. J. Am. Vet. Med. Assoc. 1982, 181, 684–689. [Google Scholar]
  10. Lombard, C.W.; Scarratt, W.K.; Buergelt, C.D. Ventricular septal defects in the horse. J. Am. Vet. Med. Assoc. 1983, 183, 562–565. [Google Scholar]
  11. Lеsсuге, F.; Тanmzali, Y. Valеurs dе гefeгеnсе en eсhoсaгdiogгaphiе T М сhеz lе сhеvаl dе sport. Rev. Méd. Vét. 1984, 135, 405–418. [Google Scholar]
  12. Stewart, J.H.; Rose, R.J.; Barko, A.M. Echocardiography in foals from birth to three months old. Equine Vet. J. 1984, 16, 332–341. [Google Scholar] [CrossRef] [PubMed]
  13. O’Callaghan, M.W. Comparison of echocardiographic and autopsy measurements of cardiac dimensions in the horse. Equine Vet. J. 1985, 17, 361–368. [Google Scholar] [CrossRef] [PubMed]
  14. Kvart, C.; Carlsten, J.; Jeffcott, L.B.; Nilsfors, L. Diagnostic value of contrast echocardiography in the horse. Equine Vet. J. 1985, 17, 357–360. [Google Scholar] [CrossRef]
  15. Reef, V.B. Evaluation of the equine cardiovascular system. Vet. Clin. N. Am. Equine Pract. 1985, 1, 275–288. [Google Scholar] [CrossRef]
  16. Zucca, E.; Ferrucci, F.; Croci, C.; Di Fabio, V.; Zaninelli, M.; Ferro, E. Echocardiographic measurements of cardiac dimensions in normal Standardbred racehorses. J. Vet. Cardiol. 2008, 10, 45–51. [Google Scholar] [CrossRef]
  17. Young, L.E. Cardiac responses to training in 2-year-old thoroughbreds: An echocardiographic study. Equine Vet. J. Suppl. 1999, 30, 195–198. [Google Scholar] [CrossRef]
  18. Buhl, R.; Ersboll, A.K.; Eriksen, L.; Koch, J. Use of color Doppler echocardiography to assess the development of valvular regurgitation in Standardbred trotters. J. Am. Vet. Med. Assoc. 2005, 227, 1630–1635. [Google Scholar] [CrossRef] [Green Version]
  19. Lombard, C.W.; Evans, M.; Martin, L.; Tehrani, J. Blood pressure, electrocardiogram and echocardiogram measurements in the growing pony foal. Equine Vet. J. 1984, 16, 342–347. [Google Scholar] [CrossRef]
  20. Slater, J.D.; Herrtage, M.E. Echocardiographic measurements of cardiac dimensions in normal ponies and horses. Equine Vet. J. Suppl. 1995, 19, 28–32. [Google Scholar] [CrossRef]
  21. Bakos, Z.; Vörös, K.; Järvinen, T.; Reiczigel, J. Two-dimensional and M-mode echocardiographic measurements of cardiac dimensions in healthy Standardbred trotters. Acta Vet. Hung. 2002, 50, 273–282. [Google Scholar] [CrossRef] [PubMed]
  22. Brown, D.J.; Rush, J.E.; MacGregor, J.; Ross, J.N., Jr.; Brewer, B.; Rand, W.M. M-mode echocardiographic ratio indices in normal dogs, cats, and horses: A novel quantitative method. J. Vet. Intern. Med. 2003, 17, 653–662. [Google Scholar] [CrossRef] [PubMed]
  23. Leadon, D.; McAllister, H.; Mullins, E.; Osborne, M. Electrocardiographic and echocardiographic measurements and their relationships in Thoroughbred yearlings to subsequent performance. Equine Exerc. Physiol. 1991, 3, 22–29. [Google Scholar]
  24. Rovira, S.; Munoz, A. Two-dimensional- and M-mode echocardiographic measurements and indices of cardiac function in Spanish colts and fillies of different age. J. Vet. Med. Sci. 2009, 71, 957–964. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Marzok, M.; Almubarak, A.I.; Al Mohamad, Z.; Salem, M.; Farag, A.M.; Ibrahim, H.M.; El-Ashker, M.R.; El-khodery, S. Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys. Animals 2022, 12, 2296. [Google Scholar] [CrossRef]
  26. Haidich, A.B. Meta-analysis in medical research. Hippokratia 2010, 14, 29–37. [Google Scholar] [PubMed]
  27. Andrel, J.A.; Keith, S.W.; Leiby, B.E. Meta-analysis: A brief introduction. Clin. Transl. Sci. 2009, 2, 374–378. [Google Scholar] [CrossRef]
  28. Stroup, D.F.; Berlin, J.A.; Morton, S.C.; Olkin, I.; Williamson, G.D.; Rennie, D.; Moher, D.; Becker, B.J.; Sipe, T.A.; Thacker, S.B. Meta-analysis of observational studies in epidemiology: A proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA 2000, 283, 2008–2012. [Google Scholar] [CrossRef]
  29. Israel, H.; Richter, R.R. A guide to understanding meta-analysis. J. Orthop. Sport Phys. Ther. 2011, 41, 496–504. [Google Scholar] [CrossRef] [Green Version]
  30. Higgins, J.P.; Thompson, S.G.; Deeks, J.J.; Altman, D.G. Measuring inconsistency in meta-analyses. BMJ 2003, 327, 557–560. [Google Scholar] [CrossRef] [Green Version]
  31. Berman, N.G.; Parker, R.A. Meta-analysis: Neither quick nor easy. BMC Med. Res. Methodol. 2002, 2, 10. [Google Scholar] [CrossRef] [Green Version]
  32. Benson, J.R.; Saeb-Parsy, K. Meta-analyses in cancer clinical trials: Principles and pitfalls. World J. Surg. 2006, 30, 1177–1183. [Google Scholar] [CrossRef]
  33. Lemmer Hunsinger, C.E.; Engel, M.E.; Stanfliet, J.C.; Mayosi, B.M. Reference intervals for the echocardiographic measurements of the right heart in children and adolescents: A systematic review. Cardiovasc. Ultrasound 2014, 12, 3. [Google Scholar] [CrossRef] [Green Version]
  34. Hall, D.J.; Cornell, C.C.; Crawford, S.; Brown, D.J. Meta-analysis of normal canine echocardiographic dimensional data using ratio indices. J. Vet. Cardiol. 2008, 10, 11–23. [Google Scholar] [CrossRef]
  35. Al-Haidar, A.; Farnir, F.; Deleuze, S.; Sandersen, C.F.; Leroux, A.A.; Borde, L.; Cerri, S.; Amory, H. Effect of breed, sex, age and body weight on echocardiographic measurements in the equine species. Res. Vet. Sci. 2013, 95, 255–260. [Google Scholar] [CrossRef] [PubMed]
  36. Collins, N.; Palmer, L.; Marr, C. Two-dimensional and M-mode echocardiographic findings in healthy Thoroughbred foals. Aust. Vet. J. 2010, 88, 428–433. [Google Scholar] [CrossRef] [PubMed]
  37. Grenacher, P.A.; Schwarzwald, C.C. Assessment of left ventricular size and function in horses using anatomical M-mode echocardiography. J. Vet. Cardiol. 2010, 12, 111–121. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  38. KRIZ, N.; ROSE, R. Repeatability of standard transthoracic echocardiographic measurements in horses. Aust. Vet. J. 2002, 80, 362–370. [Google Scholar] [CrossRef]
  39. Long, K. Standardised imaging technique for guided M-moded and Doppler echocardiography in the horse. Equine Vet. J. 1992, 24, 226–235. [Google Scholar] [CrossRef]
  40. Moher, D.; Liberati, A.; Tetzlaff, J.; Altman, D.G. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Ann. Intern. Med. 2009, 151, 264–269. [Google Scholar] [CrossRef] [Green Version]
  41. Duffield, T.F.; Rabiee, A.R.; Lean, I.J. A Meta-Analysis of the Impact of Monensin in Lactating Dairy Cattle. Part 1. Metabolic Effects. J. Dairy Sci. 2008, 91, 1334–1346. [Google Scholar] [CrossRef]
  42. Chen, B.; Wang, C.; Wang, Y.M.; Liu, J.X. Effect of biotin on milk performance of dairy cattle: A meta-analysis1. J. Dairy Sci. 2011, 94, 3537–3546. [Google Scholar] [CrossRef] [PubMed]
  43. Fleiss, J.L. The statistical basis of meta-analysis. Stat. Methods Med. Res. 1993, 2, 121–145. [Google Scholar] [CrossRef]
  44. Cohen, J. Statistical Power Analysis for the Behavioral Sciences, 2nd ed.; Erlbaum: Hillsdale, NJ, USA, 1988. [Google Scholar]
  45. Hill, A.; Spittlehouse, C. What Is Critical Appraisal? Citeseer: Princeton, NJ, USA, 2001; Volume 3. [Google Scholar]
  46. Higgins, J.P.; Green, S. Cochrane Handbook for Systematic Reviews of Interventions; John Wiley & Sons: Hoboken, NJ, USA, 2005. [Google Scholar]
  47. Thompson, S.G. Why and how sources of heterogeneity should be investigated. In Systematic Reviews in Health Care: Meta-Analysis in Context, 2nd ed.; John Wiley & Sons: Hoboken, NJ, USA, 2001; pp. 157–175. [Google Scholar]
  48. Schulz, K.F.; Chalmers, I.; Hayes, R.J.; Altman, D.G. Empirical evidence of bias. Dimensions of methodological quality associated with estimates of treatment effects in controlled trials. JAMA 1995, 273, 408–412. [Google Scholar] [CrossRef] [PubMed]
  49. Huedo-Medina, T.B.; Sanchez-Meca, J.; Marin-Martinez, F.; Botella, J. Assessing heterogeneity in meta-analysis: Q statistic or I2 index? Psychol. Methods 2006, 11, 193–206. [Google Scholar] [CrossRef] [Green Version]
  50. The EchoNoRMAL (Echocardiographic Normal Ranges Meta-Analysis of the Left Heart) Collaboration. Ethnic-Specific Normative Reference Values for Echocardiographic LA and LV Size, LV Mass, and Systolic Function: The EchoNoRMAL Study. JACC Cardiovasc. Imaging 2015, 8, 656–665. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  51. Poppe, K.K.; Doughty, R.N.; Whalley, G.A. Redefining normal reference ranges for echocardiography: A major new individual person data meta-analysis. Eur. Heart J. Cardiovasc. Imaging 2013, 14, 347–348. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Results of the literature search and disposition of echocardiographic articles screened for inclusion.
Figure 1. Results of the literature search and disposition of echocardiographic articles screened for inclusion.
Animals 13 00809 g001
Figure 2. Forest plot for interventricular septum (IVS) measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Figure 2. Forest plot for interventricular septum (IVS) measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Animals 13 00809 g002
Figure 3. Forest plot for left ventricular internal diameter (LVID) measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Figure 3. Forest plot for left ventricular internal diameter (LVID) measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Animals 13 00809 g003
Figure 4. Forest plot for left ventricular free-wall (LVFW) thickness measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Figure 4. Forest plot for left ventricular free-wall (LVFW) thickness measurements in Thoroughbred and Standardbred horses. Studies and their respective citations: Al-Haidar et al., 2013 [35]; Al-Haidar et al., 2010 [2]; Bakos et al., 2002 [21]; Brown et al., 2003 [22]; Buhl et al., 2005 [18]; Collins et al., 2010 [36]; Grenacher and Schwarzwald, 2010 [37]; Kriz et al., 2000 [38]; Leadon et al., 1991 [23]; Long et al., 1992 [39]; Michima et al., 2004 [8]; Patteson et al.,1995 [6]; Pipers and Hamlin, 1977 [7]; Slater and Herrtage, 1995 [20]; Zucca et al., 2008 [16].
Animals 13 00809 g004
Table 1. Descriptive statistics for M-mode echocardiographic measurements of cardiac diameters in Thoroughbred and Standardbred horses.
Table 1. Descriptive statistics for M-mode echocardiographic measurements of cardiac diameters in Thoroughbred and Standardbred horses.
Study NameSample SizeBreedAge Range (Year)GenderBody Weight (Kg)Variables
IVSLVIDLVFW
SystoleDiastoleSystoleDiastoleSystoleDiastole
1Al-Haidar et al., 2013 [35]36Thoroughbred2–21 Y (5.24 ± 2.34)Mares
Geldings
Stallions
86-6
(452.9 ± 52.3)
3.99 ± 1.032.57 ± 1.036.20 ± 1.0410.28 ± 1.023.16 ± 1.032.14 ± 1.03
28Standardbred1.7–21 Y
(8.9 ± 5.24)
Mares
Geldings
Stallions
370–541
(472.45 ± 36.31)
3.99 ± 1.02 2.57 ± 1.03 6.11 ± 1.03 9.98 ± 1.02 3.55 ± 1.032.14 ± 1.03
2Al-Haidar et al., 2010 [2]10Standardbred1.5–25.6 Y (10.10 ± 7.6)5 Mares
5 Geldings
120–662 kg
(459.8 ± 128.8)
4.05 ± 0.022.67 ± 0.026.25 ± 0.0510.19 ± 0.053.48 ± 0.042.00 ± 0.02
3Bakos et al., 2002 [21]23Standardbred2–16 Y (Mean 6)8 Mares
7 Stallions
8 Geldings
350–490 (Mean 427)4.7 ± 0.33.0 ± 0.2 7.0 ± 0.6 10.7 ± 0.7 3.9 ± 0.42.7 ± 0.2
4Brown et al., 2003
[22]
17Thoroughbred10.39Males450.75.26 ± 0.633.66 ± 0.548.65 ± 1.6113.92 ± 1.975.29 ± 0.893.1 ± 0.42
5Buhl et al., 2005 [18]200Standardbred3–8 Mares477 to 5403.50 ± 0.022.56 ± 0.017.66 ± 0.0411.47 ± 0.053.47 ± 0.022.39 ± 0.01
6Collins et al., 2010 [36]19ThoroughbredUp to 4 months11 Males
8 Females
190 (182.10 ± 15.16)3.09 ± 0.291.96 ± 0.225.52 ± 0.67 7.78 ± 0.752.33 ± 0.321.57 ± 0.15
7Grenacher and Schwarzwald, 2010 [37]15Standardbred>2 YGeldings
Females
539 ± 31 3.8 ± 0.55 2.5 ± 0.385.3 ± 0.89 10.2 ± 1.32 2.7 ± 0.43 1.7 ± 0.31
7Thoroughbred>2 YGeldings
Females
548 ± 59 4 ± 0.523.0 ± 0.376.6 ± 0.8710.9 ± 1.363.9 ± 0.472.2 ± 0.27
8Kriz et al., 2000 [38]13Standardbred3–4 YGeldings411 ± 104.32 ± 0.323.19 ± 0.338.07 ± 0.6911.76 ± 0.663.73 ± 0.512.51 ± 0.33
9Leadon et al., 1991 [23]600ThoroughbredMean 19.3 ± 1.2 months442 Males
158 Females
437 ± 352.0 ± 0.52.9 ± 0.46.3 ± 0.910.5 ± 0.93.8 ± 0.62.4 ± 0.4
10Long et al., 1992 [39]26Thoroughbred2–17 Y3 Stallions
5 Mares
18 Geldings
432–648 (Mean 517)4.55 ± 0.553.02 ± 0.39 7.35 ± 0.72 11.90 ± 0.713.96 ± 0.932.39 ± 0.26
11Michima et al., 2004 [8]35Standardbred5–18 YMales
Females
415.51 ± 36.764.17 ± 0.42 2.68 ± 0.29 5.94 ± 0.96 9.72 ± 0.72 4.23 ± 0.69 2.69 ± 0.32
12Patteson et al., 1995 [6]29Thoroughbred3–15 y (M 7.71 Y)22 Females
16 Geldings
420–617 (M 517)4.21 ± 0462.85 ± 0.2787.45 ± 0.61511.92 ± 0.76 3.85 ± 0.4142.32 ± 0.382
13Pipers and Hamlin, 1977 [7]25Standardbred and ThoroughbredMean 3.8 YMales
Females
300 kg4.7 ± 0.33.0 ± 0.27.0 ± 0.610.7 ± 0.33.9 ± 0.42.7 ± 0.2
14Slater and Herrtage, 1995 [20]16Thoroughbred4–16 Y
(mean 7 Y)
11 Mares
5 Geldings
450–620 (490)4.6 ± 0.22.6 ± 0.2 7.3 ± 0.8 11.2 ± 0.8 3.8 ± 0.3 2.5 ± 0.3
15Zucca et al., 2008 [16]30Standardbred3–9 Y (mean 3.8 ± 1.6 Y)11 Females
17 Male
2 Geldings
340–498 kg (435 ± 36 kg)4.48 ± 0.363.10 ± 0.417.42 ± 1.0511.64 ± 1.293.64 ± 0.522.55 ± 0.36
IVS = interventricular septum; LVID = left ventricular internal diameter; LVFW = left ventricular free wall; Y = year.
Table 2. Final meta-analysis model for reference values of echocardiographic measurements in Thoroughbred and Standardbred horses.
Table 2. Final meta-analysis model for reference values of echocardiographic measurements in Thoroughbred and Standardbred horses.
VariablesModelEffect Size and 95% Confidence IntervalsTest of Null (2-Tailed)HeterogeneityTau-Squared
Number StudiesPoint EstimateStandard ErrorVarianceCI 95%
Lower Upper
Z-Valuep-ValueQ-ValueDf (q)p-ValueI-Squared
IVSFixed152.90.10.012.83.139.5<0.001925.317<0.00198.17.9
Random156.10.60.44.77.58.7<0.001-----
LVIDFixed15−4.80.10.01−5.0−4.6−48.1<0.001844.917<0.00197.911.9
Random15−8.30.80.7−10.0−6.7−9.7<0.001-----
LVFWFixed153.10.10.012.93.241.1<0.001866.617<0.00198.16.6
Random155.40.60. 44.26.78.5<0.001-----
IVS = interventricular septum; LVID = left ventricular internal diameter; LVFW = left ventricular free wall.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Marzok, M.; Kandeel, M.; Babiker, H.; Alkhodair, K.M.; Farag, A.; Ibrahim, H.; El-Ashker, M.; Alghuwainem, Y.; El-khodery, S. M-Mode Echocardiographic Measurements of Interventricular Septum, Left Ventricular Internal Diameter, and Left Ventricular Free-Wall Thickness in Normal Horses—A Meta-Analytical Study. Animals 2023, 13, 809. https://doi.org/10.3390/ani13050809

AMA Style

Marzok M, Kandeel M, Babiker H, Alkhodair KM, Farag A, Ibrahim H, El-Ashker M, Alghuwainem Y, El-khodery S. M-Mode Echocardiographic Measurements of Interventricular Septum, Left Ventricular Internal Diameter, and Left Ventricular Free-Wall Thickness in Normal Horses—A Meta-Analytical Study. Animals. 2023; 13(5):809. https://doi.org/10.3390/ani13050809

Chicago/Turabian Style

Marzok, Mohamed, Mahmoud Kandeel, Hussein Babiker, Khalid M. Alkhodair, Alshimaa Farag, Hussam Ibrahim, Maged El-Ashker, Yousef Alghuwainem, and Sabry El-khodery. 2023. "M-Mode Echocardiographic Measurements of Interventricular Septum, Left Ventricular Internal Diameter, and Left Ventricular Free-Wall Thickness in Normal Horses—A Meta-Analytical Study" Animals 13, no. 5: 809. https://doi.org/10.3390/ani13050809

APA Style

Marzok, M., Kandeel, M., Babiker, H., Alkhodair, K. M., Farag, A., Ibrahim, H., El-Ashker, M., Alghuwainem, Y., & El-khodery, S. (2023). M-Mode Echocardiographic Measurements of Interventricular Septum, Left Ventricular Internal Diameter, and Left Ventricular Free-Wall Thickness in Normal Horses—A Meta-Analytical Study. Animals, 13(5), 809. https://doi.org/10.3390/ani13050809

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop