Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty
Abstract
:1. Introduction
2. Materials and Methods
2.1. Ions Level Determination
2.2. Oxidative Stress Determination
2.3. Physical Activity Measurement
2.4. Statistical Analysis
3. Results
3.1. Metal Blood Levels
3.2. Oxidative Stress
3.3. Implant Positioning and Level of Physical Activity
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- McKee, G.K.; Watson-Farrar, J. Replacement of Arthritic Hips by the McKee-Farrar Prosthesis. J. Bone Jt. Surg. Br. Vol. 1966, 48, 245–259. [Google Scholar] [CrossRef]
- Bozic, K.J.; Kurtz, S.; Lau, E.; Ong, K.; Chiu, V.; Vail, T.P.; Rubash, H.E.; Berry, D.J. The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States. J. Bone Jt. Surg. 2009, 91, 1614–1620. [Google Scholar] [CrossRef] [PubMed]
- De Steiger, R.N.; Hang, J.R.; Miller, L.N.; Graves, S.E.; Davidson, D.C. Five-Year Results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: An Analysis from the Australian Orthopaedic Association National Joint Replacement Registry. J. Bone Jt. Surg.-Ser. A 2011, 93, 2287–2293. [Google Scholar] [CrossRef] [PubMed]
- Langton, D.J.; Jameson, S.S.; Joyce, T.J.; Hallab, N.J.; Natu, S.; Nargol, A.V.F. Early Failure of Metal-on-Metal Bearings in Hip Resurfacing and Large-Diameter Total Hip Replacement: A Consequence of Excess Wear. J. Bone Jt. Surg.-Ser. B 2010, 92, 38–46. [Google Scholar] [CrossRef]
- Mokka, J.; Junnila, M.; Seppänen, M.; Virolainen, P.; Pölönen, T.; Vahlberg, T.; Mattila, K.; Tuominen, E.K.J.; Rantakokko, J.; Äärimaa, V.; et al. Adverse Reaction to Metal Debris after ReCap-M2A-Magnum Large-Diameter-Head Metal-on-Metal Total Hip Arthroplasty. Acta Orthop. 2013, 84, 549–554. [Google Scholar] [CrossRef]
- Galea, V.P.; Laaksonen, I.; Connelly, J.W.; Matuszak, S.J.; Nortje, M.; Madanat, R.; Muratoglu, O.; Malchau, H. What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-Metal Hip Arthroplasty? An MRI Study. Clin. Orthop. Relat. Res. 2019, 477, 353–360. [Google Scholar] [CrossRef]
- Malviya, A.; Holland, J.P. Pseudotumours Associated with Metal-on-Metal Hip Resurfacing: 10-Year Newcastle Experience. Acta Orthop. Belg. 2009, 75, 477–483. [Google Scholar]
- Kwon, Y.-M.; Ostlere, S.J.; McLardy-Smith, P.; Athanasou, N.A.; Gill, H.S.; Murray, D.W. “Asymptomatic” Pseudotumors After Metal-on-Metal Hip Resurfacing Arthroplasty. J. Arthroplast. 2011, 26, 511–518. [Google Scholar] [CrossRef]
- Pandit, H.; Glyn-Jones, S.; McLardy-Smith, P.; Gundle, R.; Whitwell, D.; Gibbons, C.L.M.; Ostlere, S.; Athanasou, N.; Gill, H.S.; Murray, D.W. Pseudotumours Associated with Metal-on-Metal Hip Resurfacings. J. Bone Jt. Surg. Br. 2008, 90-B, 847–851. [Google Scholar] [CrossRef]
- Pozzuoli, A.; Berizzi, A.; Crimì, A.; Belluzzi, E.; Frigo, A.C.; de Conti, G.; Nicolli, A.; Trevisan, A.; Biz, C.; Ruggieri, P. Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics 2020, 10, 941. [Google Scholar] [CrossRef]
- Higuchi, Y.; Seki, T.; Takegami, Y.; Komatsu, D.; Morita, D.; Ishiguro, N. Same Survival but Higher Rate of Osteolysis for Metal-on-Metal Ultamet versus Ceramic-on-Ceramic in Patients Undergoing Primary Total Hip Arthroplasty after 8 Years of Follow-Up. Orthop. Traumatol. Surg. Res. 2018, 104, 1155–1161. [Google Scholar] [CrossRef]
- Klasan, A.; Meine, E.; Fuchs-Winkelmann, S.; Efe, T.; Boettner, F.; Heyse, T.J. Are Serum Metal Ion Levels a Concern at Mid-Term Followup of Revision Knee Arthroplasty with a Metal-on-Metal Hinge Design? Clin. Orthop. Relat. Res. 2019, 477, 2007–2014. [Google Scholar] [CrossRef] [PubMed]
- Williams, S.; Schepers, A.; Isaac, G.; Hardaker, C.; Ingham, E.; van der Jagt, D.; Breckon, A.; Fisher, J. Ceramic-on-Metal Hip Arthroplasties: A Comparative in Vitro and in Vivo Study. In Clinical Orthopaedics and Related Research; Lippincott Williams and Wilkins: Philadelphia, PA, USA, 2007; Volume 465, pp. 23–32. [Google Scholar]
- Reed, M.; Achakri, H.; Bridgens, J.; Brittain, R.; Howard, P.; Wilkinson, M.; Wilton, T.; Pegg, D.; Dawson-Bowling, S.; Esler, C.; et al. The National Joint Registry 20th Annual Report. 2023. Available online: https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2020th%20Annual%20Report%202023.pdf (accessed on 15 November 2023).
- Hersnaes, P.N.; Gromov, K.; Otte, K.S.; Gebuhr, P.H.; Troelsen, A. Harris Hip Score and SF-36 Following Metal-on-Metal Total Hip Arthroplasty and Hip Resurfacing—A Randomized Controlled Trial with 5-Years Follow up Including 75 Patients. BMC Musculoskelet. Disord. 2021, 22, 781. [Google Scholar] [CrossRef] [PubMed]
- Wu, D.; Bhalekar, R.M.; Marsh, J.S.; Langton, D.J.; Stewart, A.J. Periarticular Metal Hypersensitivity Complications of Hip Bearings Containing Cobalt–Chromium. EFORT Open Rev. 2022, 7, 758–771. [Google Scholar] [CrossRef] [PubMed]
- Lee, A.; Penenberg, B.L.; Rajaee, S.S. Metallosis in Total Hip Arthroplasty. JBJS Rev. 2023, 11, 1–10. [Google Scholar] [CrossRef] [PubMed]
- Crutsen, J.R.W.; Koper, M.C.; Jelsma, J.; Heymans, M.; Heyligers, I.C.; Grimm, B.; Mathijssen, N.M.C.; Schotanus, M.G.M. Prosthetic Hip-Associated Cobalt Toxicity: A Systematic Review of Case Series and Case Reports. EFORT Open Rev. 2022, 7, 188–199. [Google Scholar] [CrossRef] [PubMed]
- Brocato, J.; Costa, M. Basic Mechanics of DNA Methylation and the Unique Landscape of the DNA Methylome in Metal-Induced Carcinogenesis. Crit. Rev. Toxicol. 2013, 43, 493–514. [Google Scholar] [CrossRef] [PubMed]
- Devlin, J.J.; Pomerleau, A.C.; Brent, J.; Morgan, B.W.; Deitchman, S.; Schwartz, M. Clinical Features, Testing, and Management of Patients with Suspected Prosthetic Hip-Associated Cobalt Toxicity: A Systematic Review of Cases. J. Med. Toxicol. 2013, 9, 405–415. [Google Scholar] [CrossRef]
- Hsu, C.W.; Raviskanthan, S.; Mortensen, P.W.; Lee, A.G. Intracranial Hypertension Associated with Arthroprosthetic Cobaltism? Am. J. Ophthalmol. Case Rep. 2022, 25, 101255. [Google Scholar] [CrossRef]
- Gessner, B.D.; Steck, T.; Woelber, E.; Tower, S.S. A Systematic Review of Systemic Cobaltism after Wear or Corrosion of Chrome-Cobalt Hip Implants. J. Patient Saf. 2019, 15, 97–104. [Google Scholar] [CrossRef]
- Bonanni, R.; Abbondante, L.; Cariati, I.; Gasbarra, E.; Tarantino, U. Metallosis after Hip Arthroplasty Damages Skeletal Muscle: A Case Report. Geriatrics 2023, 8, 92. [Google Scholar] [CrossRef]
- Stołtny, T.; Dobrakowski, M.; Augustyn, A.; Rokicka, D.; Kasperczyk, S. The Concentration of Chromium and Cobalt Ions and Parameters of Oxidative Stress in Serum and Their Impact on Clinical Outcomes after Metaphyseal Hip Arthroplasty with Modular Metal Heads. J. Orthop. Surg. Res. 2023, 18, 1–9. [Google Scholar] [CrossRef]
- Stołtny, T.; Dobrakowski, M.; Augustyn, A.; Kasperczyk, S.; Rokicka, D.; Skowroński, R.; Strojek, K.; Koczy, B. Metal-on-Metal Metaphyseal and Ceramic-on-Ceramic Femoral Neck Arthroplasty: The Impact on Clinical Results, Oxidative Stress and Concentration of Metal Ions in Serum and Blood. Eur. J. Orthop. Surg. Traumatol. 2023, 33, 3089–3097. [Google Scholar] [CrossRef]
- Valko, M.; Morris, H.; Cronin, M. Metals, Toxicity and Oxidative Stress. Curr. Med. Chem. 2005, 12, 1161–1208. [Google Scholar] [CrossRef] [PubMed]
- Jomova, K.; Raptova, R.; Alomar, S.Y.; Alwasel, S.H.; Nepovimova, E.; Kuca, K.; Valko, M. Reactive Oxygen Species, Toxicity, Oxidative Stress, and Antioxidants: Chronic Diseases and Aging. Arch. Toxicol. 2023, 97, 2499–2574. [Google Scholar] [CrossRef]
- Thanan, R.; Oikawa, S.; Hiraku, Y.; Ohnishi, S.; Ma, N.; Pinlaor, S.; Yongvanit, P.; Kawanishi, S.; Murata, M. Oxidative Stress and Its Significant Roles in Neurodegenerative Diseases and Cancer. Int. J. Mol. Sci. 2014, 16, 193–217. [Google Scholar] [CrossRef] [PubMed]
- Chan, F.W.; Bobyn, J.D.; Medley, J.B.; Krygier, J.J.; Tanzer, M. The Otto Aufranc Award. Wear and Lubrication of Metal-on-Metal Hip Implants. Clin. Orthop. Relat. Res. 1999, 369, 10–24. [Google Scholar] [CrossRef]
- Chang, J.S.; Haddad, F.S. Revision Total Hip Arthroplasty for Metal-on-Metal Failure. J. Clin. Orthop. Trauma. 2020, 11, 9–15. [Google Scholar] [CrossRef]
- Vendittoli, P.-A.; Mottard, S.; Roy, A.G.; Dupont, C.; Lavigne, M. Chromium and Cobalt Ion Release Following the Durom High Carbon Content, Forged Metal-on-Metal Surface Replacement of the Hip. J. Bone Jt. Surg. Br. 2007, 89-B, 441–448. [Google Scholar] [CrossRef]
- Brodner, W.; Grübl, A.; Jankovsky, R.; Meisinger, V.; Lehr, S.; Gottsauner-Wolf, F. Cup Inclination and Serum Concentration of Cobalt and Chromium after Metal-on-Metal Total Hip Arthroplasty. J. Arthroplast. 2004, 19, 66–70. [Google Scholar] [CrossRef]
- Williams, S.; Leslie, I.; Isaac, G.; Jin, Z.; Ingham, E.; Fisher, J. Tribology and Wear of Metal-on-Metal Hip Prostheses: Influence of Cup Angle and Head Position. J. Bone Jt. Surg. 2008, 90, 111–117. [Google Scholar] [CrossRef]
- Hannemann, F.; Hartmann, A.; Schmitt, J.; Lützner, J.; Seidler, A.; Campbell, P.; Delaunay, C.P.; Drexler, H.; Ettema, H.B.; García-Cimbrelo, E.; et al. European Multidisciplinary Consensus Statement on the Use and Monitoring of Metal-on-Metal Bearings for Total Hip Replacement and Hip Resurfacing. Orthop. Traumatol. Surg. Res. 2013, 99, 263–271. [Google Scholar] [CrossRef] [PubMed]
- Alvarez, A.; Domenech, J.; Valverde-Mordt, C.; Lison, J.F. Correlation between the Level of Physical Activity as Measured by Accelerometer and the Harris Hip Score. HIP Int. 2015, 25, 461–465. [Google Scholar] [CrossRef]
- Tönnis, D.; Heinecke, A. Current Concepts Review Acetabular and Femoral Anteversion: Relationship with Osteoarthritis of the Hip. J. Bone Jt. Surg. Am. 1999, 81, 1747–1770. [Google Scholar] [CrossRef] [PubMed]
- Jensen, M.P.; Karoly, P.; Braver, S. The Measurement of Clinical Pain Intensity: A Comparison of Six Methods. Pain 1986, 27, 117–126. [Google Scholar] [CrossRef] [PubMed]
- Navarro Collado, M.J.; Peiró Moreno, S.; Ruiz Jareño, L.; Payá Rubio, A.; Hervás Juan, M.T.; López Matéu, P. Validation of the Harris Hip Score in Rehabilitation after Hip Arthroplasty. Rehabilitación 2005, 39, 147–154. [Google Scholar] [CrossRef]
- Bae, Y.; Hansen, L. Recommendations on Measurement Units-Why and How On Behalf of the IFCC-IUPAC Committee on Nomenclature for Properties and Units (C-NPU). EJIFCC 2019, 30, 250–275. [Google Scholar]
- Koper, M.C.; Hesseling, B.; Tuinebreijer, W.E.; van der Linden, H.; Mathijssen, N.M.C. Safe Upper Limits of Serum Cobalt and Chromium Levels for a Metal-on-Metal Total Hip Bearing: A 10-Year Follow-Up Study. J. Arthroplast. 2021, 36, 2080–2086. [Google Scholar] [CrossRef] [PubMed]
- Terwee, C.B.; Bouwmeester, W.; van Elsland, S.L.; de Vet, H.C.W.; Dekker, J. Instruments to Assess Physical Activity in Patients with Osteoarthritis of the Hip or Knee: A Systematic Review of Measurement Properties. Osteoarthr. Cartil. 2011, 19, 620–633. [Google Scholar] [CrossRef]
- Kiloatar, H.; Kurt, G. Perception of benefits-barriers of exercise, physical activity level, and body awareness in women with premenstrual syndrome. J. Obstet. Gynaecol. Res. 2023, 50, 120–127. [Google Scholar] [CrossRef]
- Roman-Viñas, B.; Serra-Majem, L.; Hagströmer, M.; Ribas-Barba, L.; Sjöström, M.; Segura-Cardona, R. International Physical Activity Questionnaire: Reliability and Validity in a Spanish Population. Eur. J. Sport. Sci. 2010, 10, 297–304. [Google Scholar] [CrossRef]
- Di Puccio, F.; Mattei, L. Biotribology of Artificial Hip Joints. World J. Orthop. 2015, 6, 77–94. [Google Scholar] [CrossRef] [PubMed]
- Migliorini, F.; Pilone, M.; Bell, A.; Merfort, R.; Giorgino, R.; Maffulli, N. Serum Cobalt and Chromium Concentration Following Total Hip Arthroplasty: A Bayesian Network Meta-Analysis. Sci. Rep. 2023, 13, 6918. [Google Scholar] [CrossRef]
- Lainiala, O.; Karsikas, M.; Reito, A.; Eskelinen, A. Whole Blood Chromium Concentration Is Very Rarely Elevated Independently of Whole Blood Cobalt. Sci. Rep. 2021, 11, 12352. [Google Scholar] [CrossRef] [PubMed]
- Alvarez, C.C.; Bravo Gómez, M.E.; Hernández Zavala, A. Hexavalent Chromium: Regulation and Health Effects. J. Trace Elem. Med. Biol. 2021, 65, 126729. [Google Scholar] [CrossRef] [PubMed]
- Antoniou, J.; Zukor, D.J.; Mwale, F.; Minarik, W.; Petit, A.; Huk, O.L. Metal Ion Levels in the Blood of Patients After Hip Resurfacing: A Comparison Between Twenty-Eight and Thirty-Six-Millimeter-Head Metal-on-Metal Prostheses. J. Bone Jt. Surg. 2008, 90, 142–148. [Google Scholar] [CrossRef] [PubMed]
- Langton, D.J.; Jameson, S.S.; Joyce, T.J.; Gandhi, J.N.; Sidaginamale, R.; Mereddy, P.; Lord, J.; Nargol, A.V.F. Accelerating Failure Rate of the ASR Total Hip Replacement. J. Bone Jt. Surg. Br. 2011, 93-B, 1011–1016. [Google Scholar] [CrossRef] [PubMed]
- Cadossi, M.; Mazzotti, A.; Baldini, N.; Giannini, S.; Savarino, L. New Couplings, Old Problems: Is There a Role for Ceramic-on-Metal Hip Arthroplasty? J. Biomed. Mater. Res. B Appl. Biomater. 2016, 104, 204–209. [Google Scholar] [CrossRef]
- Saracco, M.; Maccauro, G.; Urbani, A.; Ciavardelli, D.; Persichilli, S.; Ancillai, G.; Pasqualetti, P.; Calvisi, V.; Logroscino, G. Ceramic-on-Metal Bearing in Short Stem Total Hip Arthroplasty: Ions, Functional and Radiographic Evaluation at Mid-Term Follow-Up. HIP Int. 2020, 30, 52–58. [Google Scholar] [CrossRef]
- Mehta, N.; Patel, D.; Leong, J.; Brown, P.; Carroll, F.A. Functional Outcomes & Metal Ion Levels Following Ceramic on Metal Total Hip Arthroplasty: 9 Year Follow-Up. J. Orthop. 2021, 24, 131–134. [Google Scholar] [CrossRef] [PubMed]
- Hossini, H.; Shafie, B.; Niri, A.D.; Nazari, M.; Esfahlan, A.J.; Ahmadpour, M.; Nazmara, Z.; Ahmadimanesh, M.; Makhdoumi, P.; Mirzaei, N.; et al. A Comprehensive Review on Human Health Effects of Chromium: Insights on Induced Toxicity. Environ. Sci. Pollut. Res. 2022, 29, 70686–70705. [Google Scholar] [CrossRef] [PubMed]
- Manninen, E.; Lainiala, O.; Karsikas, M.; Reito, A.; Jämsä, P.; Eskelinen, A. Do Cobalt or Chromium Accumulate in Metal-on-Metal Hip Arthroplasty Patients Who Have Mild, Moderate, or Severe Renal Insufficiency? Bone Jt. J. 2021, 103-B, 1231–1237. [Google Scholar] [CrossRef] [PubMed]
- Corradi, M.; Daniel, J.; Ziaee, H.; Alinovi, R.; Mutti, A.; McMinn, D.J.W. Early Markers of Nephrotoxicity in Patients with Metal-on-Metal Hip Arthroplasty. In Clinical Orthopaedics and Related Research; Springer New York LLC.: New York, NY, USA, 2011; Volume 469, pp. 1651–1659. [Google Scholar]
- Marker, M.; Grübl, A.; Riedl, O.; Heinze, G.; Pohanka, E.; Kotz, R. Metal-on-Metal Hip Implants: Do They Impair Renal Function in the Long-Term? A 10-Year Follow-up Study. Arch. Orthop. Trauma. Surg. 2008, 128, 915–919. [Google Scholar] [CrossRef] [PubMed]
- Lange, J.; Wach, A.; Koch, C.N.; Hopper, R.H.; Ho, H.; Engh, C.A.; Wright, T.M.; Padgett, D.E. Do Well-Functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion? Clin. Orthop. Relat. Res. 2018, 476, 2017–2024. [Google Scholar] [CrossRef]
- Okazaki, Y.; Gotoh, E. Comparison of Metal Release from Various Metallic Biomaterials in Vitro. Biomaterials 2005, 26, 11–21. [Google Scholar] [CrossRef]
- Ochocki, K.; Stołtny, T.; Ostałowska, A.; Wróbel, M.; Rokicka, D.; Pasek, J.; Kasperczyk, S.; Strojek, K.; Koczy, B. Antioxidant System and Ions Concentrations after Femoral Neck and Resurfacing Hip Arthroplasty. Med. Sci. Monit. 2022, 28, e936335. [Google Scholar] [CrossRef]
- Bernstein, M.; Walsh, A.; Petit, A.; Zukor, D.J.; Antoniou, J. Femoral Head Size Does Not Affect Ion Values in Metal-on-Metal Total Hips. Clin. Orthop. Relat. Res. 2011, 469, 1642–1650. [Google Scholar] [CrossRef] [PubMed]
- Tkaczyk, C.; Petit, A.; Antoniou, J.; Zukor, D.J.; Tabrizian, M.; Huk, O.L. Significance of Elevated Blood Metal Ion Levels in Patients with Metal-on-Metal Prostheses: An Evaluation of Oxidative Stress Markers. Open Orthop. J. 2010, 4, 221–227. [Google Scholar] [CrossRef]
- Savarino, L.; Fotia, C.; Roncuzzi, L.; Greco, M.; Cadossi, M.; Baldini, N.; Giannini, S. Does Chronic Raise of Metal Ion Levels Induce Oxidative DNA Damage and Hypoxia-like Response in Patients with Metal-on-Metal Hip Resurfacing? J. Biomed. Mater. Res. B Appl. Biomater. 2017, 105, 460–466. [Google Scholar] [CrossRef]
- Nermin Emam, B.M.; Alsaied Ahmed, D.; Mesbah, A.; Mansour, M.; Sh Hamed, S. Malondialdehyde and total antioxidant capacity as predictors biomarkers of mortality in acute aluminium phosphide poisoning. Egypt. Soc. Clin. Toxicol. J. 2021, 9, 34–46. [Google Scholar] [CrossRef]
- Chaves, T.R.; Lima, R.P.A.; Ribeiro, M.R.; Boico, V.F.; De Lima Ferreira, F.E.L.; Da Conceição Rodrigues Gonçalves, M.; De Almeida, A.T.C.; De Moraes, R.M.; Silva, A.S.; Cardoso, G.A.; et al. Association between Values of Anthropometric Indicators, Total Antioxidant Capacity and Malondialdehyde in Adults: A Population-Based Study. Nutr. Clin. Y Diet. Hosp. 2021, 41, 47–57. [Google Scholar] [CrossRef]
- Sultana, R.; Shahin, A.D.; Jawadul, H.M. Measurement of Oxidative Stress and Total Antioxidant Capacity in Hyperthyroid Patients Following Treatment with Carbimazole and Antioxidant. Heliyon 2022, 8, e08651. [Google Scholar] [CrossRef] [PubMed]
- Langton, D.J.; Jameson, S.S.; Joyce, T.J.; Webb, J.; Nargol, A.V.F. The Effect of Component Size and Orientation on the Concentrations of Metal Ions after Resurfacing Arthroplasty of the Hip. J. Bone Jt. Surg. Br. Vol. 2008, 90, 90–1143. [Google Scholar] [CrossRef] [PubMed]
- Bowsher, J.G.; Clarke, I.C.; Williams, P.A.; Donaldson, T.K. What Is a “Normal” Wear Pattern for Metal-on-Metal Hip Bearings? J. Biomed. Mater. Res. B Appl. Biomater. 2009, 91B, 297–308. [Google Scholar] [CrossRef] [PubMed]
- Hothi, H.S.; Eskelinen, A.P.; Berber, R.; Lainiala, O.S.; Moilanen, T.P.S.; Skinner, J.A.; Hart, A.J. Factors Associated with Trunnionosis in the Metal-on-Metal Pinnacle Hip. J. Arthroplast. 2017, 32, 286–290. [Google Scholar] [CrossRef]
- Kwon, Y.-M.; MacAuliffe, J.; Peng, Y.; Arauz, P. The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty. J. Arthroplast. 2018, 33, 2631–2635. [Google Scholar] [CrossRef]
M-M | C-M | Control | p Value | |
---|---|---|---|---|
n | 25 | 25 | 25 | n.s. |
Women | 10 (40%) | 10 (40%) | 12 (48%) | n.s. |
Age (years) | 63 (range 46–79) | 65 (range 37–82) | 62 (range 37–82) | n.s. |
Weight (kg) | 80.5 ± 16.7 | 79.6 ± 11.3 | 79.8 ± 12.6 | n.s. |
BMI (kg/m2) | 29 ± 5.1 | 30.2 ± 4.8 | 29.4 ± 4.9 | n.s. |
HHS | 86.5 ± 12.7 | 86.2 ± 9.9 | - | n.s. |
VAS | 2.2 ± 2.6 | 1.3 ±1.8 | - | n.s. |
Metal Ion | M-M (n = 25) | C-M (n = 25) | Control (n = 25) | p Value | |
---|---|---|---|---|---|
Cobalt (nmol/L) | 65.9 ± 58.0 | 20.1 ± 14.8 | 5.8 ± 2.7 | p < 0.001 | M-M vs. C-M p < 0.001 C-M vs. control p = 0.32 M-M vs. control p < 0.001 |
Cobalt (µg/L) | 3.8 ± 3.4 | 1.2 ± 0.8 | 0.3 ± 0.1 | ||
Chromium (nmol/L) | 51.6 ± 39.4 | 31.1 ± 4.91 | 29.1 ± 1.8 | p = 0.001 | M-M vs. C-M p = 0.04 C-M vs. control p = 0.17 M-M vs. control p < 0.02 |
Chromium (µg/L) | 2.6 ± 2 | 1.6 ± 0.2 | 1.5 ± 0.09 |
Spearman’s Rho | Creatinine | Urea | |
---|---|---|---|
Chrome | R | 0.367 * | 0.334 * |
Sig. (bilateral) | 0.017 | 0.028 | |
Cobalt | R | −0.223 | 0.179 |
Sig. (bilateral) | 0.155 | 0.252 |
Total (M-M and C-M) | M-M | C-M | Control | p Value | |
---|---|---|---|---|---|
TAC | 4.4 ± 2.3 | 4.5 ± 2.5 | 4.25 ± 2.1 | 5.0 ± 2.3 | n.s. |
MDA | 2.1 ± 1.2 | 1.90 ± 1.1 | 2.5 ± 1.2 | 2.2 ± 1.2 | n.s. |
Spearman’s Rho | TAC | MDA | |
---|---|---|---|
Chrome | R | 0.204 | −0.162 |
Sig. (bilateral) | 0.13 | 0.24 | |
Cobalt | R | R | 0.073 |
Sig. (bilateral) | P | 0.59 |
Mean ± SD | Range | |
---|---|---|
Accelerometer (counts/minute) | 156.7 ± 72.3 | 18–309 |
UCLA | 5.6 ± 1.4 | 3–10 |
IPAQ | 1.9 ± 0.6 | 1–3 |
Spearman’s Rho | Accelerometer | UCLA | IPAQ | Head Size | Cup Size | Cup Orientation | ||
---|---|---|---|---|---|---|---|---|
M-M | Cr | R | −0.314 | −0.227 | −0.070 | −0.234 | −0.311 | 0.138 |
P | 0.219 | 0.380 | 0.788 | 0.261 | 0.131 | 0.509 | ||
Co | R | −0.216 | −0.110 | −0.162 | 0.301 | 0.037 | 0.097 | |
P | 0.406 | 0.675 | 0.534 | 0.144 | 0.861 | 0.645 | ||
C-M | Cr | R | −0.309 | 0.312 | −0.084 | . | −0.072 | −0.092 |
P | 0.161 | 0.169 | 0.717 | . | 0.762 | 0.663 | ||
Co | R | 0.001 | −0.089 | 0.243 | . | 0.242 | 0.377 | |
P | 0.996 | 0.701 | 0.289 | . | 0.303 | 0.063 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Gómez-Álvarez, J.; Miranda, I.; Álvarez-Llanas, A.; Lisón, J.F.; Bosch-Morell, F.; Doménech, J. Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty. J. Clin. Med. 2024, 13, 527. https://doi.org/10.3390/jcm13020527
Gómez-Álvarez J, Miranda I, Álvarez-Llanas A, Lisón JF, Bosch-Morell F, Doménech J. Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty. Journal of Clinical Medicine. 2024; 13(2):527. https://doi.org/10.3390/jcm13020527
Chicago/Turabian StyleGómez-Álvarez, Jorge, Ignacio Miranda, Alejandro Álvarez-Llanas, Juan F. Lisón, Francisco Bosch-Morell, and Julio Doménech. 2024. "Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty" Journal of Clinical Medicine 13, no. 2: 527. https://doi.org/10.3390/jcm13020527
APA StyleGómez-Álvarez, J., Miranda, I., Álvarez-Llanas, A., Lisón, J. F., Bosch-Morell, F., & Doménech, J. (2024). Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty. Journal of Clinical Medicine, 13(2), 527. https://doi.org/10.3390/jcm13020527