Next Article in Journal
Age-Related Increase in Type C Tympanogram
Next Article in Special Issue
Renal Denervation in Heart Failure Treatment: Data for a Self-Fulfilling Prophecy
Previous Article in Journal
Minimally Invasive Mitral Valve Surgery in Elderly Patients: Results from a Multicenter Study
Previous Article in Special Issue
The Impact of the Withdrawal of SGLT2 Inhibitors on Clinical Outcomes in Patients with Heart Failure
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Smartphone App-Based Remote Monitoring Challenges in Patients with Cardiac Resynchronization Therapy Defibrillators—A Multicenter Study

by
Dagmar Kowal
1,2,
Marek Prech
3,
Agnieszka Katarzyńska-Szymańska
4,
Artur Baszko
5,
Grzegorz Skonieczny
6,
Elżbieta Wabich
7,
Maciej Kempa
7,
Błażej Rubiś
1,* and
Przemysław Mitkowski
4
1
Department of Clinical Chemistry and Molecular Diagnostics, Poznan University of Medical Sciences, 60-806 Poznan, Poland
2
Doctoral School, Poznan University of Medical Sciences, 60-812 Poznan, Poland
3
Department of Cardiology, Provincial Hospital, 64-100 Leszno, Poland
4
1st Department of Cardiology, Poznan University of Medical Sciences, 60-355 Poznan, Poland
5
2nd Department of Cardiology, Poznan University of Medical Sciences, 61-485 Poznan, Poland
6
Department of Cardiology, Provincial Polyclinic Hospital, 87-100 Torun, Poland
7
Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-210 Gdansk, Poland
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2024, 13(21), 6323; https://doi.org/10.3390/jcm13216323
Submission received: 8 October 2024 / Revised: 19 October 2024 / Accepted: 21 October 2024 / Published: 23 October 2024

Abstract

:
Background/Objectives: Remote monitoring (RM) cardiac implantable electronic devices for adults delivers improved patient outcomes. However, previously used bedside transmitters are not optimal due to deficient patient adherence. The goal of this study was to evaluate the efficacy of RM regarding the connectivity of smartphone app-based solutions, adherence to scheduled automatic follow-ups, and prevalence of alert-based events. Methods: We evaluated the adult heart failure (HF) population with an implanted cardiac resynchronization therapy defibrillator (CRT-D) divided into two arms: with app-based RM (abRM) and without app-based RM (control). Results: A total of 81 patients (median age of 69.0) were included in our study. Sixty-five patients received a CRT-D with abRM functionality, and sixteen did not. Twelve patients had no smartphone, and two provided no consent, resulting in their transfer to the control group. Finally, the abRM arm consisted of 51 patients, while 30 patients were in the control group. The median period of follow-up lasted 12 months. Among abRM patients, 98.0% successfully transmitted their first scheduled follow-up, and 80.4% were continuously monitored. Alert-based events were mainly related to arrhythmic events and device functionality with significantly shorter median times to notification (1 day vs. 101 days; p < 0.0001) in the abRM group. Conclusions: Our study showed a high level of compliance with timely initial transmission and adherence to scheduled remote follow-ups. Patient enrollment eligibility was a major challenge due to the limited accessibility of smartphones in the population. App-based RM demonstrated an accurate notification of events and patient-initiated transmissions in emergencies, regardless of location.

1. Introduction

Since 2015, remote monitoring (RM) has been recognized as a component of care for adult patients with implanted cardiac implantable electronic devices (CIEDs), and class I recommendation was granted by international physician societies [1,2]. The significant reduction in notification time from the onset of ventricular and supraventricular arrhythmias to their evaluation (including silent arrhythmias), the early detection of lead or device malfunction, and monitoring battery status were documented [3,4,5,6]. Commencing RM within 2–4 weeks of a new CIED implant and conducting remote, scheduled follow-ups every 3 months for adult patients is advised [2]. Daily remote checks of predefined alert events leading to prompt diagnoses of arrhythmic episodes or device-based events are essential to system functionality. Consequently, the organized and well-structured reaction of the dedicated medical team to the alerts recorded and available on the manufacturers’ servers results in earlier clinical responses, a reduction in inappropriate diagnoses, a reduction in the hospitalization rate, and the improvement of patient prognosis and clinical outcome, as emphasized in the latest consensus [2]. One of the critical factors in RM is compliance, defined as the total number of adult patients with CIEDs enrolled in RM, the execution of initial remote transmissions within 2–4 weeks of new CIED implantation, and adherence to automatic follow-up intervals according to guidelines. As emphasized, the final compliance and success rates of RM are affected by maintaining continuous connectivity between the CIED, transmitter, and manufacturer server [2]. Several studies revealed that RM based on bedside transmitters achieved suboptimal patient compliance, ranging from 53 to 79% [7,8]. The potential explanations for decreased adherence to the scheduled follow-up pattern were the transmitter type, patients’ socioeconomic status, age, gender, and geographic localization [9,10]. The implementation of smartphone app-based technology communicating with CIEDs via low-energy Bluetooth (BLE) protocols might offer solutions to the listed challenges. Consequently, applying the app-based solution presented a reduction in traditional bedside transmitters’ deficiencies, which resulted in improved patient engagement, compliance, and final rates of successfully delivered transmissions, ranging from 92% to 94.6% [11,12]. However, further evaluation is needed, especially examining the challenges faced by HF patients with an implanted cardiac resynchronization therapy defibrillator (CRT-D) using new technologies and the medical team conducting their supervision.
The goal of this study was to evaluate the efficacy of RM regarding the connectivity of smartphone app-based solutions, adherence to scheduled automatic follow-ups, and prevalence of alert-based events.

2. Materials and Methods

2.1. Patients

A prospective analysis was conducted on HF patients who had a CRT-D implanted between November 2020 and April 2024 at five hospitals: 1st and 2nd Department of Cardiology at Poznan University of Medical Science; Department of Cardiology and Electrotherapy at Medical University of Gdansk; Department of Cardiology at Provincial Policlinic Hospital in Torun; and Department of Cardiology at Provincial Hospital in Leszno. The indications for CRT were in accordance with the guidelines at the time of implantation [13]. Patient consent was collected. Patients were divided into two arms: implanted with a BLE-enabled CRT-D eligible for app-based monitoring (Neutrino NxT HF, Abbott, Plymouth, MN, USA) available in academic centers, and a control group without BLE capability in non-academic ones. Initially, patients were randomized based on clinical data. However, due to limited smartphone availability (which is underlined in Section 4), some patients had to be reclassified, resulting in a loss of comparability between groups. Of interest, despite the observed selection bias, patients’ characteristics were comparable to the population with CIEDs in real-world HF registries [3,5,7,14]. The goal was to accomplish a 2:1 propensity score match. During the study, only one manufacturer offered BLE-enabled devices on Polish market. RM was not reimbursed or academic centers had not yet signed a reimbursement agreement with the National Health Fund. Therefore, patients enrolled in RM received remote follow-up analysis as a part of a research project. Patients were enrolled in the RM system before discharge, at home, or during their first planned outpatient clinic visit. A combined follow-up protocol was initiated for RM patients: automatically, every 61 days, remote follow-ups with daily alert checks were carried out and regular, outpatient clinic visits took place every 6–12 months.
For control group patients, every 6–12 months, outpatient clinic follow-ups were conducted. During our study, no delegated medical team was established, as RM reimbursement was not yet introduced. The study’s primary investigator was supported in each hospital by a cardiologist, experienced in CRT-D implantation and follow-ups. Remote transmissions were regularly evaluated via the internet-accessible website (merlin.net, Abbott). If the loss of communication alert was delivered, a telephone call to the patient was made. During the enrollment procedure, a questionnaire was conducted to verify if the patient possessed a smartphone. Additionally, their level of familiarity with smartphones was measured by five questions, regarding app installation, text messaging, sending pictures, reading emails, and checking weather forecasts. No or one positive response was interpreted as low, 2–3 as moderate, and 4–5 as a high level of familiarity. The second questionnaire was used to evaluate patients’ experience in using the app and its four functions: manual transmission, device status, history of transmissions, and technical support. Both questionnaires were specifically designed for this study and were not pre-validated; hence, their design was simple and uncomplicated to make it easier for patients to choose. The questionnaires were reviewed by implanting physicians and were tested with the five pre-enrolment HF patients to confirm patients’ full understanding and ensure the device’s reliability and validity. The Supplementary Materials presents all questions from both surveys. Patients enrolled in RM received support for their CRT-D in terms of app pairing and operating the app, including instructions on manual transmission activation. The importance of daily connections conducted automatically at night was highlighted to patients in order to ensure the best adherence and compliance with the scheduled or alert transmissions. The analysis of parameters was performed as previously described [15]. Briefly, patient demographics, clinical data regarding cardiac diagnosis, indications for CRT-D implantation, RM compliance defined as the time to enrollment and the first transmission, and RM adherence defined as the number and regularity of planned follow-up transmissions were analyzed. Furthermore, the total duration of RM and the detection of alert-based and clinical events were investigated. The types of alert-based events were classified into groups with respect to device functioning (lead dysfunction, high pacing output, battery status) and arrhythmic events. Also, the time from RM enrollment to the first alert transmission was determined, and the time to notification, identified as the availability on the merlin.net platform, excluding weekends and holidays, was also reported. Additional outpatient or clinic appointments for a patient were organized if the justified alert-based transmission was triggered. In the control group, similarly, the time from implantation to the first event was measured, whereas the time to notification was calculated from the event occurrence to the patient appearance in the outpatient clinic for a scheduled visit or in the emergency facility if the event was symptomatic. The hospital records were the source of information regarding patient’s death.
All patients underwent thorough evaluation of RM efficacy to measure compliance, which was defined as the overall enrollment of CRT-D patients in RM, commencing RM transmission within 2–4 weeks of enrollment, and adherence to the planned, remote follow-up interval (61 days).

2.2. Statistics

Descriptive statistics were used to present data such as mean, standard deviation, or median with interquartile range (Q1, Q3), range, number of events, frequency of prevalence, and percentages. The normal distribution was verified by the Shapiro–Wilk test. The Mann–Whitney and Chi-square with Yates correction test were conducted to compare unpaired groups. All statistical analyses were performed in Tibco Statistica software version 13 (StatSoft, Tulsa, OK, USA). A two-tailed p-value < 0.05 was considered a statistically significant difference.

3. Results

A total of 81 patients were included in our study (74 males and 7 females). The median (Q1, Q3) patient age at implantation was 69.0 (60, 74) years. Baseline patients’ characteristics are available in Table 1. The group of 65 patients (80.2%) received a CRT-D with app-based RM functionality, and 16 patients (19.8%) without. In the first group, twelve patients had no smartphone and two patients did not provide consent, resulting in their transfer to the control group. Thus, the RM arm consisted of 51 patients, while 30 patients were in the control group (Figure 1). Among 51 patients in the RM arm, 11 had decided to purchase a smartphone to be eligible for active monitoring.
Patients were followed up remotely over a median period of 12 (5, 24) months. The control group was observed in the outpatient clinic over a median period of 27 (24, 30) months. During the follow-up, no patient deaths were recorded in the RM group and two patient deaths in the mechanism of HF progression in the control group. Control group patients had lower LVEF, a higher incidence of ischemic etiology, and a longer median follow-up time. No statistical significance was shown (p = 0.260) that could be related to the limited sample size or follow-up time. No deaths were related to device dysfunction (Table 2).

3.1. Compliance with App-Based RM

The median (Q1, Q3) time from CRT-D implantation to remote monitoring enrollment was 1 day (1, 7). There were 36 patients (70.6%) with successfully paired apps and who had initiated monitoring before discharge. The remaining patients (29.4%) were enrolled in RM via a telephone call, with family assistance while staying at home, except one patient who was paired at an outpatient clinic. The main reasons for the delay were the lack of adequate smartphones followed by an intentional purchase, insufficient Internet coverage at the hospital, or deficient rights of the user’s phone.
Out of 65 patients who received a CRT-D capable of app-based RM, 51 patients (78.5%) were successfully enrolled in the RM system. Twelve patients who had no smartphone nor any intention of upgrading and two others who did not provide consent were transferred to the control group. The most common causes of RM ineligibility were socioeconomic status and concomitant, age-related diseases such as dementia, stroke, and eye diseases. In the RM arm, 50 patients (98.0%) had their first scheduled follow-up successfully sent. The group of 41 patients (80.4%) were continuously monitored during the observation, and all follow-up transmissions were delivered according to schedule (Figure 2).
Further analysis of the recruitment questionnaire demonstrated that all patients who purchased the smartphone fulfilled the criteria of being continuously monitored, whereas among the group of 19.6% of patients with missed scheduled transmissions, three patients possessed low familiarity, three possessed moderate, and four possessed a high level of familiarity with smartphones. In this group, 6 out of 10 patients expressed no experience in app installation (Figure 3). Patients with mean age of 81.0 presented low familiarity with required technology. The evaluation of patients’ app experience questionnaire revealed that 84.0% of patients who had activated the app and had their first scheduled follow-up successfully sent used mainly two out of the four app functionalities: transmissions history and device status. Our data did not report an excessive use of the manual transmission feature. Out of twenty-two patients who sent intentional transmissions, four executed it more than five times, one was prompted by a medical team, and seventeen occurred during the first month of enrollment.
Our analysis also exposed accidental BLE disconnection or turning off the RM app as the most common cause of decreased connectivity. A group of RM patients contacted us directly and asked for assistance in repairing the app while changing or upgrading their phone, but events were solved ad hoc and not recorded; therefore, the data are incomplete.

3.2. RM Alert-Based Transmissions vs. Control Group

In the app-based RM group, 42 events were observed in 25 patients (49.0%) as follows: 88.1% were appropriately diagnosed, followed by a justified alert transmission, and 11.9% showed a false positive notification. The median (Q1, Q3) time to the first transmission was 158 (19, 372) days, and the median time to notification was 1 (1, 2) day. Further analysis of the appropriately detected alert-based events showed that 20 were related to arrhythmic events and 22 to device functioning (Table 3).
Similar analyses were conducted for the control group with respect to arrhythmic and device functioning events (Table 4). The median time to the first event was 381 (55, 614) days, and the median notification delay was 101 (52, 168) days. Although there was a difference in the occurrence of first events in both groups, no statistical significance was found (p = 0.084). A shorter median period to notification in the app-based RM group was noted: 1 day vs. 101 days (p = 0.0001) (Figure 4).

4. Discussion

In this first Polish real-world, prospective, multicenter study on the efficacy of smartphone app-based RM in HF patients with CRT-Ds, we showed a high level of connectivity as evidenced by good compliance with timely initial transmissions (98.0%) and adherence to scheduled remote follow-ups (80.4%). According to the guidelines, the RM should be regarded as a standard of care in HF patients with CIEDs. The patient enrollment and commencing RM transmission should be conducted within 2–4 weeks of implantation or device exchange, followed by scheduled remote follow-ups every 3 months and every 12 months for outpatient clinic visits [2]. Altogether, in our study, we met the requirements of the swift activation of RM, but the patient’s enrollment outcome was suboptimal. The 78.5% success rate was mainly influenced by socioeconomic status and concomitant diseases, which resulted in a lack of smartphone to download the monitoring app and a lack of an understanding of the clinical benefits of RM. Similar conclusions were recently presented from 10 Italian hospitals and 495 patients (67 ± 13 years), where 84% had access to smartphones, 85% were willing to use the HF monitoring app, but only 63% downloaded the app [16]. This shows that the challenges we encountered during patient enrollment to RM are comparable in the European Union region. Therefore, we should consider optimized patient selection for remote monitoring programs to achieve a high level of connectivity, utilizing the latest communication technologies coupled with growing patient awareness and confidence in using informative communication platforms, as was recently emphasized by Tedeschi A et al. [17].
An important role in the high enrollment ratio is not only the medical team but also family assistance with the patient’s app in the CIED pairing process. In our group, 29.4% of patients executed pairing at home with family support. This shows that this process could be performed out of the clinic, possibly with phone support. During the study, we noticed the growing patient awareness of RM advantages, mainly those related to reimbursement introduced in mid-2023 and broadly covered by media. This resulted in 11 patients purchasing a smartphone to use beneficial app-based RM. At the same time, technological headway makes smartphones more common among seniors, and current smartphone users will become older; therefore, the challenges with suboptimal eligibility will gradually decline. The pace of technology adoption can be geography- and socioeconomics-related. The recent study conducted on a group exceeding 18,000 US patients demonstrated an enrollment level of 94.4% in the app-based group and 85.0% in the bedside transmitters group [18]. The remaining group of technologically excluded patients should be offered different solutions for RM, such as mobile transmitters or traditional bedside transmitters, as provided by manufacturers. However, the disadvantages of immobile solutions should be taken into consideration. In our previous study with pediatric patients with implanted pacemakers and bedside transmitters, the enrollment success rate was 100.0%, as each patient received a paired transmitter at discharge or in an outpatient clinic. Unfortunately, the adherence was suboptimal, especially during the holiday season, when 34.8% of patients missed scheduled transmissions [15].
In our study, 98.0% of patients had the first planned follow-up successfully sent, and 80.4% of patients participated in continuous surveillance without losing scheduled transmissions, which were planned every 61 days. This reveals that smart and mobile technologies solve connectivity challenges in RM, primarily related to bedside systems. These results are in concordance with recently published data presenting adherence in app-based solutions in the range of 92.0–94.6% [11,12,18].
Acknowledging the patient experience of using an app is crucial for final compliance. We noticed increased patient engagement in the therapy process via app-built functionality. Patients’ experience evaluations revealed that scheduled transmission history and battery status were the most frequently and intentionally used app features. Furthermore, no excessive use of the manual transmission feature creating a work overload for the medical team was observed among monitored patients. Patients also contacted research team members for support in maintaining and continuing RM when their smartphone was upgraded and the repairing security code was lost. This demonstrates patients’ perceptions of safety and their understanding of continuous RM for long-term clinical outcomes. Similar insights into the patient experience emerge from recent studies [12,18,19,20]. Furthermore, the patients’ perception of remote and virtual visits has changed since COVID-19. The Italian researchers reported not only increased patient satisfaction from virtual visits, but also a preference for virtual visits over in-clinic ones among 86.4% of examined patients. Importantly, the remote management strategy presented in that study reported no significant differences in clinical outcomes in comparison to in-clinic visits [21].

Alert-Based Transmissions

Remote monitoring is recommended for the early detection of arrhythmic events, especially asymptomatic ones, and device and lead dysfunction [3]. Our evaluation presented that 88.1% of events in the app-based RM group were appropriately diagnosed with a median time of 158 (19, 372) days. The median time to events in the control group was twice as long (158 vs. 381). In our opinion, the presented difference (statistically insignificant) may result from a limited number of the study group and a mismatch in the percentage of ischemic and non-ischemic cardiomyopathies of baseline patients characteristics. However, this ischemic substrate variance does not influence the time from event occurrence to notifying the medical team, which is directly related to the patient monitoring method. Our findings revealed a median notification delay of 1 (1, 2) day in the app-based RM group and 101 (52, 168) days in the control group. The prompt notification reported in the app-based RM group can potentially reduce the risk of adverse events from silent arrhythmias, reduce hospitalization time, reduce HF decompensation, and prevent its recurrence. The observed proportions of notification time in the studied population are in accordance with the results of the previously published Connect Trial (4.6 vs. 22 days) and the Evolvo Study (1.4 vs. 24.8 days), respectively [5,22]. As the time to notification in our study in the RM arm is improved, it implicates that app-based technology may offer superior efficacy to bedside transmitters in the rapid detection of alert-based events. Other reports show that app-based technology provides better connectivity than bedside transmitters [11,12,18] mainly due to their lower mobility, which may pose a risk of decreased success rates.
However, with respect to delayed notification times, the meta-analysis conducted by Parthiban et al. presented a significant mean difference in the days to clinical decision/event detection of 27.1 days [23]. The difference presented in our research is larger and may result from the limited study population or the lack of sufficient data regarding medical decisions from the implanting center. Nevertheless, the main study goal was to evaluate the efficacy of the app-based RM solution as an alternative to the traditional bedside system, not to conventional in-office follow-ups. The superiority of RM has been well analyzed and is reflected in the 2023 HRS/EHRA/APHRS/LAHRS expert consensus [2].
The improved patient engagement due to available smartphone-based technologies and enhanced communication capabilities between the patient and the medical team were presented recently in a case report. Both the swift diagnosis of silent AF and the confirmation of terminated VF via manual transmission followed by hospital admission were described [24].

5. Limitations

The technology examined in our study was commercially introduced in the European Union in November 2020. Throughout the entire period of our research, only one manufacturer commercially offered BLE-enabled CRT-Ds in Poland; therefore, the analysis could not be extended to other devices with respect to the RM arm. Furthermore, RM was not reimbursed for most of our study period. Therefore, BLE-enabled CRT-Ds were implanted only in academic centers, and patients enrolled in RM received remote follow-up analysis as a part of a research project, but not from a dedicated hospital unit. Patients who did not qualify for the RM arm (no smartphone or no consent) were moved to the control group at the discretion of the implanting physician. Therefore, we cannot completely rule out selection bias. The process of patients’ reclassification resulted in the loss of balance between the groups with respect to clinical data and HF etiology. It seems unlikely, however, that the observed disproportion in clinical data may influence both the measured reaction time to alert events and the evaluation of app-based RM efficacy. Although the number of participants was calculated at the beginning of the study, the patients’ enrollment was influenced by the COVID-19 pandemic and impacted sample size.

6. Conclusions

Our real-world, prospective, multicenter study showed a high level of connectivity enabled by the good compliance with timely initial transmissions (98.0%) and adherence to scheduled remote follow-ups (80.4%). Patient enrollment eligibility was a major challenge due to the limited accessibility of smartphones in the population, but it will likely improve as the technology becomes more widespread. App-based RM demonstrated the ability to provide swift and accurate notifications of alert-triggered events and patient-initiated transmissions in emergencies, regardless of location.
Our findings are consistent with previously published results regarding CIEDs and provide broader insights into the situation of heart failure patients monitored with smartphone apps, identifying key areas for improvement.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/jcm13216323/s1, Patient questionnaire—2020–2024.

Author Contributions

Conceptualization, D.K., B.R., M.P. and A.B.; methodology, D.K., B.R. and M.P.; investigation, D.K., A.K.-S., M.P., A.B., G.S., E.W., M.K. and M.P.; writing—original draft preparation, D.K. and M.P.; writing—review and editing, B.R. and P.M.; supervision, B.R. and P.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research received funding from Polish Ministry of Science and Higher Education, grant number DWD/4/56/2020.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Institutional Ethics Committee of Poznan University of Medical Sciences (protocol code 805/20 on 4 November 2020).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Please use sentence: Data are contained within the article and Supplementary Materials.

Acknowledgments

The research has been conducted as part of a PhD thesis at the Doctoral School in Poznan University of Medical Science and is part of a large doctoral project supported by a grant of the Polish Ministry of Science and Higher Education.

Conflicts of Interest

D.K.—Abbott employment. Other authors declare no conflicts of interest.

References

  1. Slotwiner, D.; Varma, N.; Akar, J.G.; Annas, G.; Beardsall, M.; Fogel, R.I.; Galizio, N.O.; Glotzer, T.V.; Leahy, R.A.; Love, C.J.; et al. HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devices. Heart Rhythm. 2015, 12, e69-100. [Google Scholar] [CrossRef] [PubMed]
  2. Ferrick, A.M.; Raj, S.R.; Deneke, T.; Kojodjojo, P.; Lopez-Cabanillas, N.; Abe, H.; Boveda, S.; Chew, D.S.; Choi, J.-I.; Dagres, N.; et al. 2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic. Europace 2023, 25, euad123. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  3. Chiu, C.S.L.; Timmermans, I.; Versteeg, H.; Zitron, E.; Mabo, P.; Pedersen, S.S.; Meine, M.; for the REMOTE-CIED Trial Investigators. Effect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: Secondary results of the REMOTE-CIED randomized trial. Europace 2022, 24, 256–267. [Google Scholar] [CrossRef] [PubMed]
  4. Varma, N.; Love, C.J.; Michalski, J.; TRUST Investigators; Epstein, A.E. Alert-based ICD follow-up: A model of digitally driven remote patient monitoring. JACC Clin. Electrophysiol. 2021, 7, 976–987. [Google Scholar] [CrossRef] [PubMed]
  5. Crossley, G.H.; Boyle, A.; Vitense, H.; Chang, Y.; Mead, R.H.; Connect Investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: The value of wireless remote monitoring with automatic clinician alerts. J. Am. Coll. Cardiol. 2011, 57, 1181–1189. [Google Scholar] [CrossRef] [PubMed]
  6. Kempa, M.; Sławiński, G.; Zieleniewicz, P.; Dziurkowski, Ł.; Wabich, E.; Budrejko, S.; Zienciuk-Krajka, A.; Daniłowicz-Szymanowicz, L. Implementation of remote monitoring in patients implanted with T-ICD and S-ICD involved in a recall campaign: An excellent tool with insufficient availability. Kardiol. Pol. 2023, 81, 612–615. [Google Scholar] [CrossRef] [PubMed]
  7. Rosenfeld, L.E.; Patel, A.S.; Ajmani, V.B.; Holbrook, R.W.; Brand, T.A. Compliance with remote monitoring of ICDS/CRTDS in a real-world population. Pacing Clin. Electrophysiol. 2014, 37, 820–827. [Google Scholar] [CrossRef]
  8. Varma, N.; Piccini, J.P.; Snell, J.; Fischer, A.; Dalal, N.; Mittal, S. The relationship between level of adherence to automatic wireless remote monitoring and survival in pacemaker and defibrillator patients. J. Am. Coll. Cardiol. 2015, 65, 2601–2610. [Google Scholar] [CrossRef] [PubMed]
  9. Mantini, N.; Borne, R.T.; Varosy, P.D.; Rosenberg, M.A.; Marzec, L.N.; Sauer, W.H.; Nguyen, D.T. Use of cell phone adapters is associated with reduction in disparities in remote monitoring of cardiac implantable electronic devices. J. Interv. Card. Electrophysiol. 2021, 60, 469–475. [Google Scholar] [CrossRef] [PubMed]
  10. Theuns, D.A.; Radhoe, S.P.; Brugts, J.J. Remote monitoring of heart failure in patients with implantable cardioverter-defibrillators: Current status and future needs. Sensors 2021, 21, 3763. [Google Scholar] [CrossRef] [PubMed]
  11. Tarakji, K.G.; Zaidi, A.M.; Zweibel, S.L.; Varma, N.; Sears, S.F.; Allred, J.; Roberts, P.R.; Shaik, N.A.; Silverstein, J.R.; Maher, A.; et al. Performance of first pacemaker to use smart device app for remote monitoring. Heart Rhythm. O2 2021, 2, 463–471. [Google Scholar] [CrossRef] [PubMed]
  12. Tilz, R.; Shaik, N.; Piorkowski, C.; Hu, Y.; Connolly, A.; Reyes, I.; Nabutovsky, Y.; Fischer, A.; Ip, J. Real-world Adoption of Smartphone-based Remote Monitoring Using the Confirm Rx™ Insertable Cardiac Monitor. J. Innov. Card. Rhythm. Manag. 2021, 12, 4613–4620. [Google Scholar] [CrossRef] [PubMed]
  13. Priori, S.G.; Blomström-Lundqvist, C.; Mazzanti, A.; Blom, N.; Borggrefe, M.; Camm, J.; Elliott, P.M.; Fitzsimons, D.; Hatala, R.; Hindricks, G.; et al. Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). 2015 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: The Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC) Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Europace 2015, 17, 1601–1687. [Google Scholar] [CrossRef] [PubMed]
  14. Bonhorst, D.; Guerreiro, S.; Fonseca, C.; Cardim, N.; Macedo, F.; Adragão, P. Real-life data on heart failure before and after implantation of resynchronization and/or defibrillation devices—The Síncrone study. Rev. Port Cardiol. (Engl. Ed.) 2019, 38, 33–41, English, Portuguese. [Google Scholar] [CrossRef] [PubMed]
  15. Kowal, D.; Baszko, A.; Czyż, K.; Bobkowski, W.; Mitkowski, P.; Rubiś, B. Pacemaker remote monitoring challenges in pediatric population: Single center long term experience. Kardiol. Pol. 2024, 82, 308–314. [Google Scholar] [CrossRef] [PubMed]
  16. Ziacchi, M.; Molon, G.; Giudici, V.; Botto, G.L.; Viscusi, M.; Brasca, F.; Santoro, A.; Curcio, A.; Manzo, M.; Mauro, E.; et al. Integration of a Smartphone HF-Dedicated App in the Remote Monitoring of Heart Failure Patients with Cardiac Implantable Electronic Devices: Patient Access, Acceptance, and Adherence to Use. J. Clin. Med. 2023, 12, 5528. [Google Scholar] [CrossRef] [PubMed]
  17. Tedeschi, A.; Palazzini, M.; Trimarchi, G.; Conti, N.; Di Spigno, F.; Gentile, P.; D’Angelo, L.; Garascia, A.; Ammirati, E.; Morici, N.; et al. Heart Failure Management through Telehealth: Expanding Care and Connecting Hearts. J. Clin. Med. 2024, 13, 2592. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  18. Manyam, H.; Burri, H.; Casado-Arroyo, R.; Varma, N.; Lennerz, C.; Klug, D.; Carr-White, G.; Kolli, K.; Reyes, I.; Nabutovsky, Y.; et al. Smartphone-based cardiac implantable electronic device remote monitoring: Improved compliance and connectivity. Eur. Heart J. Digit. Health 2022, 4, 43–52. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  19. Tan, V.H.; See Tow, H.X.; Fong, K.Y.; Wang, Y.; Yeo, C.; Ching, C.K.; Lim, T.W. Remote monitoring of cardiac implantable electronic devices using smart device interface versus radiofrequency-based interface: A systematic review. J. Arrhythm. 2024, 40, 596–604. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  20. Tajstra, M.; Dyrbuś, M.; Grabowski, M.; Rokicki, J.K.; Nowak, M.; Gąsior, M. The use of remote monitoring of patients with cardiac implantable electronic devices in Poland. Kardiol. Pol. 2022, 80, 479–481. [Google Scholar] [CrossRef] [PubMed]
  21. Mariani, M.V.; Pierucci, N.; Forleo, G.B.; Schiavone, M.; Bernardini, A.; Gasperetti, A.; Mitacchione, G.; Mei, M.; Giunta, G.; Piro, A.; et al. The Feasibility, Effectiveness and Acceptance of Virtual Visits as Compared to In-Person Visits among Clinical Electrophysiology Patients during the COVID-19 Pandemic. J. Clin. Med. 2023, 12, 620. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  22. Landolina, M.; Perego, G.B.; Lunati, M.; Curnis, A.; Guenzati, G.; Vicentini, A.; Parati, G.; Borghi, G.; Zanaboni, P.; Valsecchi, S.; et al. Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study. Circulation 2012, 125, 2985–2992. [Google Scholar] [CrossRef] [PubMed]
  23. Parthiban, N.; Esterman, A.; Mahajan, R.; Twomey, D.J.; Pathak, R.K.; Lau, D.H.; Roberts-Thomson, K.C.; Young, G.D.; Sanders, P.; Ganesan, A.N. Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes. J. Am. Coll. Cardiol. 2015, 65, 2591–2600. [Google Scholar] [CrossRef] [PubMed]
  24. Kowal, D.; Katarzyńska-Szymańska, A.; Prech, M.; Rubiś, B.; Mitkowski, P. Early smartphone app-based remote diagnosis of silent atrial fibrillation and ventricular fibrillation in a patient with cardiac resynchronization therapy defibrillator. J. Cardiovasc. Dev. Dis. 2023, 10, 30. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Cohort diagram of the study population.
Figure 1. Cohort diagram of the study population.
Jcm 13 06323 g001
Figure 2. App-based remote monitoring compliance in adult patients with cardiac resynchronization therapy defibrillators.
Figure 2. App-based remote monitoring compliance in adult patients with cardiac resynchronization therapy defibrillators.
Jcm 13 06323 g002
Figure 3. Familiarity and experience of patients with regard to smartphone functionality in the group of patients with noncontinuous remote follow-up. The mean age of patients with low smartphone familiarity was 81.0 years.
Figure 3. Familiarity and experience of patients with regard to smartphone functionality in the group of patients with noncontinuous remote follow-up. The mean age of patients with low smartphone familiarity was 81.0 years.
Jcm 13 06323 g003
Figure 4. Time to first event and time to notification.
Figure 4. Time to first event and time to notification.
Jcm 13 06323 g004
Table 1. Baseline characteristics of patients.
Table 1. Baseline characteristics of patients.
Study CohortGroup with App-Based RMGroup w/o App-Based RMp Value
N = 81N = 51N = 30
Age, median (Q1, Q3), years69.0 (60, 74)67.5 (57, 75)69.0 (64, 72)0.924
Male gender73 (90.1%)46 (90.2%)27 (90.0%)0.721
Cardiomyopathy:
         ischemic46 (56.8%)24 (47.1%)21 (70.0%)0.076
         nonischemic31 (38.3%)25 (49.0%)7 (23.3%)0.041
         other4 (4.9%)2 (3.9%)2 (6.7%)0.984
NYHA class II or III64 (79.0%) 46 (90.2%)19 (63.3%)0.008
History of atrial fibrillation/atrial flutter17 (21.0%)13 (25.5%)4 (13.3%)0.310
ICD indication: primary prevention64 (79.0%)41 (80.4%)23 (76.7%)0.908
LV ejection fraction (%)30.0 (25–35)30.0 (25–35)25.0 (20–30)0.026
LBBB71 (87.7%)46 (90.2%)25(83.3%)0.578
Diabetes mellitus26 (32.1%)13 (25.5%)13 (43.3%)0.157
Chronic renal failure28 (34.6%)17 (33.3%)11 (36.7%)0.950
CABG7 (8.6%)4 (7.8%)3 (10.0%)0.940
NT-proBNP, median (Q1, Q3), (pg/mL)1818.0 (543, 3362)1291.0 (449, 2985)2500.5 (1349, 5456)0.111
CRP, median (Q1, Q3), (mg/L)4.0 (2, 8)4.0 (2, 8)4.0 (2, 8)0.993
Legend: NYHA—New York Heart Association, ICD—implantable cardioverter-defibrillator, LV—left ventricle, LBBB—left bundle brunch block, CABG—coronary artery bypass graft.
Table 2. Remote monitoring and control group characteristics.
Table 2. Remote monitoring and control group characteristics.
Number of patients capable of app-based RM65
Number of patients enrolled in RM51 (78.5%)
Patients:
         no smartphone12 (18.5%)
         no consent2 (3.1%)
         purchased smartphone11 (16.9%)
RM follow-up time, median (Q1, Q3), (min–max), months12 (5, 24), (1–40)
Patients with at least 1 FU after RM enrollment50 (98.0%)
Continuous adherence to RM FU scheme41 (80.4%)
Actively monitored patients at final analysis38 (74.5%)
Control group follow-up time, median (Q1, Q3), (min–max), months27 (24, 30), (11–41)
Patients died in monitored group0
Patients died in control group2
Legend: RM—remote monitoring, FU—follow up.
Table 3. Remote monitoring alert-based transmissions.
Table 3. Remote monitoring alert-based transmissions.
Number of Patients with RM51DiagnosisCRT-D DiagnosticsCorrective Action
Patients with first alert transmission25 (49.0%)
First alert transmissions42
Alert types:
VF3 (7.1%)Ventricular fibrillationIEGM1 VF—hospitalization, 2 VFs—inappropriate detection of AF with fast V conduction; device reprogramming and medication adjustment
VT1 (2.4%)Ventricular tachycardiaIEGMMedication adjustment
nsVT10 (23.9%)Ventricular non-sustained arrhythmiasHVR histogram + IEGMMedication adjustment
AMS6 (14.3%)Atrial fibrillation/atrial flutterAMS histogram + IEGM4 AF episodes, 2 AFl episodes, medication adjustment, and/or cardioversion
BiV less then limit2 (4.8%)Premature ventricular complexesRhythm diagnostics + counters + histogramMedication adjustment
High capture output3 (7.1%)RV/LV pacing deficitReal time IEGM + high capture output + threshold trendDevice reprogramming, observation
Sense amplitude below threshold3 (7.1%)A/V signal dropAutomatic signal measurements + trend2 in A channel and 1 in V channel, observation
Non-sustained V oversensing11 (26.2%)Intermittent post BiV T-wave oversensingIEGMDevice reprogramming
AMS due to oversensing3 (7.1%)Farfield, V oversensing in atrial channelAMS IEGM + oversensing evaluationDevice reprogramming
Legend: RM—remote monitoring, CRT-D—cardiac resynchronization therapy defibrillator, VF—ventricular fibrillation, VT—ventricular tachyarrhythmia, nsVT—none sustained ventricular tachyarrhythmia, AF—atrial fibrillation, AFl—atrial flutter, IEGM—intracardiac electrogram, HVR—high ventricular rate, AMS—auto mode switch, BiV—biventricular, A—atrial, V—ventricular, RV—right ventricle, LV—left ventricle.
Table 4. Control group event episodes.
Table 4. Control group event episodes.
Number of Patients w/o RM30DiagnosisCRT-D DiagnosticsCorrective Action
Patients with first event episodes20 (66.7%)
First event episodes occurrence25
Events types:
VT3 (12.0%)Ventricular tachycardiaIEGMMedication adjustment
nsVT8 (32.0%)Ventricular non-sustained arrhythmiasHVR histogram + IEGMMedication adjustment
AMS8 (32.0%)Atrial fibrillation/atrial flutter/atrial tachycardia/oversensingAMS histogram + IEGM1 AF episode, 1 AFl episodes, 5 AT episodes, medication adjustment and/or cardioversion, observation, 1 Far R oversensing resulted in device reprogramming
Sense amplitude below threshold2 (8.0%)V signal dropautomatic signal measurements + trend2 in V channel, observation
Non-sustained V oversensing2 (8.0%)Intermittent post BiV T-wave oversensingIEGMDevice reprogramming
Lead impedance, noise2 (8.0%)RV lead disfunctionImpedance trend, IEGM noise1 RV lead replacement,
1 observation
Legend: RM—remote monitoring, CRT-D—cardiac resynchronization therapy defibrillator, VT—ventricular tachyarrhythmia, nsVT—none sustained ventricular tachyarrhythmia, AF—atrial fibrillation, AFl—atrial flutter, IEGM—intracardiac electrogram, HVR—high ventricular rate, AMS—auto mode switch, BiV—biventricular, V—ventricular, RV—right ventricle.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Kowal, D.; Prech, M.; Katarzyńska-Szymańska, A.; Baszko, A.; Skonieczny, G.; Wabich, E.; Kempa, M.; Rubiś, B.; Mitkowski, P. Smartphone App-Based Remote Monitoring Challenges in Patients with Cardiac Resynchronization Therapy Defibrillators—A Multicenter Study. J. Clin. Med. 2024, 13, 6323. https://doi.org/10.3390/jcm13216323

AMA Style

Kowal D, Prech M, Katarzyńska-Szymańska A, Baszko A, Skonieczny G, Wabich E, Kempa M, Rubiś B, Mitkowski P. Smartphone App-Based Remote Monitoring Challenges in Patients with Cardiac Resynchronization Therapy Defibrillators—A Multicenter Study. Journal of Clinical Medicine. 2024; 13(21):6323. https://doi.org/10.3390/jcm13216323

Chicago/Turabian Style

Kowal, Dagmar, Marek Prech, Agnieszka Katarzyńska-Szymańska, Artur Baszko, Grzegorz Skonieczny, Elżbieta Wabich, Maciej Kempa, Błażej Rubiś, and Przemysław Mitkowski. 2024. "Smartphone App-Based Remote Monitoring Challenges in Patients with Cardiac Resynchronization Therapy Defibrillators—A Multicenter Study" Journal of Clinical Medicine 13, no. 21: 6323. https://doi.org/10.3390/jcm13216323

APA Style

Kowal, D., Prech, M., Katarzyńska-Szymańska, A., Baszko, A., Skonieczny, G., Wabich, E., Kempa, M., Rubiś, B., & Mitkowski, P. (2024). Smartphone App-Based Remote Monitoring Challenges in Patients with Cardiac Resynchronization Therapy Defibrillators—A Multicenter Study. Journal of Clinical Medicine, 13(21), 6323. https://doi.org/10.3390/jcm13216323

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop