Next Article in Journal
Amino Acid Metabolites and Slow Weight Loss in the Early Postoperative Period after Sleeve Gastrectomy
Next Article in Special Issue
Digital Dentistry: Advances and Challenges
Previous Article in Journal
Evaluation of Obesity Management Recorded in Electronic Clinical History: A Cohort Study
Previous Article in Special Issue
How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Clinical Outcomes of Root-Analogue Implants Restored with Single Crowns or Fixed Dental Prostheses: A Retrospective Case Series

by
Mats Wernfried Heinrich Böse
1,*,
Detlef Hildebrand
2,
Florian Beuer
1,
Christian Wesemann
1,
Paul Schwerdtner
3,
Stefano Pieralli
4 and
Benedikt Christopher Spies
4
1
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Institute for Dentistry, Oral and Maxillofacial Surgery, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Campus Benjamin Franklin (CBF), Aßmannshauser Str. 4–6, 14197 Berlin, Germany
2
Private Dental Office Dr. Detlef Hildebrand, Westhafenstraße 1, 13353 Berlin, Germany
3
Institute of Mathematics MA 4–5, Technical University Berlin, Straße des 17. Juni 136, 10623 Berlin, Germany
4
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2020, 9(8), 2346; https://doi.org/10.3390/jcm9082346
Submission received: 1 July 2020 / Revised: 20 July 2020 / Accepted: 21 July 2020 / Published: 23 July 2020
(This article belongs to the Collection Digital Dentistry: Advances and Challenges)

Abstract

:
The objective was to investigate clinical and radiological outcomes of rehabilitations with root-analogue implants (RAIs). Patients restored with RAIs, supporting single crowns or fixed dental prostheses, were recruited for follow-up examinations. Besides clinical and esthetical evaluations, X-rays were taken and compared with the records. Patients were asked to evaluate the treatment using Visual Analogue Scales (VAS). For statistical analyses, mixed linear models were used. A total of 107 RAIs were installed in one dental office. Of these, 31 were available for follow-up examinations. For those remaining, survival has been verified via phone. RAIs were loaded after a mean healing time of 6.6 ± 2.5 months. 12.1 ± 6.9 months after loading, a mean marginal bone loss (MBL) of 1.20 ± 0.73 mm was measured. Progression of MBL significantly decreased after loading (p = 0.013). The mean pink and white esthetic score (PES/WES) was 15.35 ± 2.33 at follow-up. A survival rate of 94.4% was calculated after a mean follow-up of 18.9 ± 2.4 months after surgery. Immediate installation of RAIs does not seem to reduce MBL, as known from the literature regarding screw-type implants, and might not be recommended for daily routine. Nevertheless, they deliver esthetically satisfying results.

1. Introduction

Dental implants are successfully used for the replacement of missing and hopeless teeth with a mean survival rate of 94.6 ± 5.97% after 10 years of clinical service [1]. Concerning the loss of adjacent bone and soft tissues as a result of tooth extraction [2], immediate implant placement has been purported to help reducing resorption processes [3]. However, a generalized recommendation whether immediate, immediate-delayed, or delayed installation of prefabricated screw-shaped implants should be generally preferred was not scientifically evidenced to date [4,5]. Benefits of immediate surgical procedures are still subject to current investigations [6].
Resorption processes after tooth extraction have been part of scientific research since the twentieth century [7]. With the objective to counteract these processes by replacing extracted roots/teeth with anatomically shaped copies, the Dental Polymer Implant Concept was already introduced in 1969 [8]. Since then, scientific research on root-analogue implants (RAIs) have been conducted repeatedly with variations in used materials and methods in the literature [9,10,11,12,13,14,15,16,17]. Thereby, the technical possibilities and concepts did indeed allow for the fabrication of root-analogues but not for immediate implant installation in the proper meaning of the word. This resulted in a temporal offset between the removal of the teeth and implant installations. In order to allow for immediate implant installation of RAIs, they needed to be manufactured prior to the extractions. With the help of Digital Imaging and Communication in Medicine (DICOM) data gathered from Cone Beam Computed Tomographies (CBCT), accurate production of RAIs has been made possible prior to surgery [18,19]. However, no long-term clinical data and studies are available, allowing for critical assumptions regarding the former treatment concepts.
In 2013, Natural Dental Implants (NDI Berlin) launched the REPLICATE Immediate Tooth Replacement System on the dental market. Based on the combination of DICOM data and Standard Triangulation/Tesselation Language (STL) data of the intraoral clinical situations, the RAIs were manufactured in a subtractive manner prior to extraction/surgery. Regarding material selection, a one-piece hybrid-version (the endosseous part of the implant is made of titanium and glass-fused to the zirconia abutment) and a one-piece zirconia version was available. The entire endosseous implant surface was enlarged by macro and micro retentions to allow for primary stability during re-installation of the replica. In 2017, a case report described an excellent outcome concerning the clinical and radiographic results [20]. Some authors compared the procedure to the so-called “The Digital One-Abutment/One-Time Concept” [21], another approach aiming to preserve soft and hard tissues using screw-shaped implants. As a result, more clinical data regarding the REPLICATE Immediate Tooth Replacement System was deemed necessary in 2018 [22]. This investigation intended to provide more clinical data and form the basis for further prospective studies on RAIs. The collected data is considered valuable for future investigations and forthcoming developments of root-analogue implant systems. Since the concept of RAIs fulfils the claim for customization and the belief in progressive digitization within dentistry [23], upcoming research on fully individualized implants seems likely.
This retrospective case series was designed to investigate the survival and success rates of rehabilitations with the REPLICATE Immediate Tooth Replacement System seeking for potential clinical, radiological, and social impacts. With a focus on marginal bone loss (MBL) and esthetic outcomes, the objective was to identify advantages and/or disadvantages and provide preliminary data to validate routine clinical applicability. The working hypothesis was that immediate implantations with customized root-analogue implants show comparable clinical, radiographical, and esthetical results to conventional screw-shaped implants.

2. Experimental Section

This study was designed as a clinical retrospective case series. Ethical approval was given by the Ethical Committee of Charité—Universitätsmedizin Berlin, Germany (application number: EA4/140/18). All surgical procedures and follow-up examinations were performed in the private dental office of an experienced dentist focusing on oral surgery in Berlin (author D.H.). D.H. performed all surgical procedures, and the author, M.B., performed all clinical follow-up examinations. All patients received and signed an informed consent form and patient information prior to examinations. In addition to the Case Report Forms (CRFs) completed by the investigator, each participant was asked to assess his own perception of the treatment by applying Visual Analogue Scales (VAS). This research was conducted considering the STROBE statement for observational studies.
To be considered for a treatment with a RAI in the dental office of the study, the patients had to be non-smokers and were not allowed to take any medication affecting the bone metabolism. Regarding the unmaintainable teeth, surrounding soft and hard tissues had to be non-inflammatory, surrounding bone compartments had to be intact, and periodontal gaps had to be visible on CBCTs. The surgeon (D.H.) already conducted the selection of patients during implant consultations, and many RAI surgeries were already performed before the development of the present study. Rejected cases for a RAI treatment were not documented in the dental office. In total, 107 RAIs were inserted between September 2016 and August 2019 in the dental office of the study. Treatments were performed on patients, with an agreement to be treated with a RAI, and met the inclusion criteria. They were referred by their general dentists from all over Germany or introduced themselves on their own initiative. The REPLICATE Immediate Tooth Replacement System had already been approved for the German dental market at the time of all surgeries.
Existing and collected data were anonymized, retrospectively analyzed, and statistically evaluated comparing the patients CRFs and VAS ratings with the detailed records deemed necessary from the manufacturer. Patient inclusion criteria for clinical follow-up examinations in this study were: (1) Treated with the REPLICATE Immediate Tooth Replacement System; (2) completed healing after surgery according to the surgeon; and (3) RAIs restored with single crowns or fixed dental prostheses. All patients treated with a RAI in the dental office refusing to join for follow-up were excluded from the statistical analyses. However, they were included in the calculation of a preliminary overall survival rate in case of confirmation of survival by the patients themselves or the records of the referring dentists. All patients were tried to contact by phone repeatedly by the reception staff of D. H. or the author, M. B. However, only 28 patients treated with 31 RAIs agreed and participated in the follow-up investigations. The reduced study participation compared to total surgeries emphasizes the study practice as part of a dental referral network and the widely dispersed residencies of the treated patients. The dental office was one of a few practices that offered a treatment with this system throughout Germany. Figure 1 provides an overview of this study as a flow diagram.
Detailed planning was required prior to surgical procedures. To fabricate the RAIs, dental impressions with a customized tray and a polyether material (Impregum, 3M Deutschland GmbH, Neuss, Germany), a bite record in habitual occlusion (Futar D, Kettenbach GmbH & Co. KG, Eschenburg, Germany), DICOM data from a CBCT (PAX i-3D, VATECH, Hwaseong-si, Gyeonggi-do, South Korea), completed order forms, and clinical photographs were required by NDI Berlin. Models were fabricated (type IV plaster), digitized with a laboratory scanner, and exported in STL data format. The STL and DICOM data were superimposed by a trained specialist of the manufacturer. Temporary Protective Covers (TPCs), implant portions, abutment portions, and Try-Ins (exact copies of the RAIs to evaluate the fit prior to installation) were virtually designed. Both the design engineer and the dentist checked the design of the datasets. Depending on the dentist’s preferences, adjustments to the design were carried out. When approved, the DICOM data were converted into STL datasets and sent to the Computer Aided Manufacturing (CAM)-computers, which generated the Network Common Data Format (NetCDF; nc) to control the milling machines. Regardless of hybrid or all-ceramic RAIs, the surfaces of the implant portions were enlarged using macro and micro retentions. To avoid compression of the alveolar bone, the intra-bony part was individually reduced compared to the original size of the root.
After pre-surgical planning and delivery of the RAIs, immediate installation took place. Hopeless teeth (Figure 2a) were removed as atraumatically as possible to maintain the surrounding bone. Where possible, the Benex Extraction-System (Benex Extraction-System, Helmut Zepf Medizintechnik GmbH, Seitlingen-Oberflacht, Germany) was used (Figure 2b), facilitating atraumatic vertical tooth removal with a reported mean success rate of 83% [24]. If planned and necessary, the bone compartments were adjusted on an individual basis. Before unpacking and insertion of the final RAI, the anticipated fit in the extraction socket was evaluated by using the Try-Ins (Figure 2c,d). All implant surfaces were wetted with Plasma Rich Growth Factors (PRGFs; BTI Biotechnology Institute, San Antonio, Spain). Since PRGFs might promote bone regeneration, it was used for augmentation of the voids [25]. Thereafter, the RAIs were carefully placed into position with a hammer and a mallet (Figure 2e–g). Subsequent to surgery, supplied TPCs were adhesively attached to one or both adjacent teeth, depending on the design (Figure 2h,i). A gap of approximately 0.6 mm between the TPCs and the abutments of the RAIs served as load protection. To investigate the state of healing, examinations usually took place 3–6 month after surgery, whereas the temporaries were carefully removed, and X-rays were taken. After successful osseointegration (Figure 2j), conventional impressions of the abutment for the manufacturing of the final restorations were made. The prosthetic restorations of the RAIs were delivered in the study center and in the referring dental offices (Figure 2l).
When setting up this retrospective evaluation, follow-up examinations were scheduled as soon as possible in consultation with the patients. The CRFs included an update of the anamnesis, surgical, prosthetic, and implant-specific parameters. Radiographs and clinical photographs of the restorations were taken at the follow-up examinations. VAS’ were used for the assessment of patient-reported outcomes. Referring to a systematic review published in 2012, success was determined including 4 superordinate categories: (1) Implant level; (2) Peri-implant soft tissue; (3) Prosthetic level; (4) and Patient satisfaction; this considers the complexity of rehabilitations with implant supported restorations [26].
To evaluate success at the implant level radiographs were evaluated at three different times: (1) Surgery (T0); (2) (prior to) Loading (T1); and (3) Follow-up examination (T2). All relevant radiographs were analyzed with ImageJ, an open source image processing program designed for scientific multidimensional images (developed by Wayne Rasband). To calculate the bone loss, defined reference points of the digital RAI constructions (provided by NDI Berlin) were transferred to the radiographs and converted using parallels and the rule of three (Figure 3a–e). All points were defined and checked by the surgeon (D.H.) and the investigator (M.B.). They were independently measured by a single external private lecturer with experience in clinical studies to reduce subjective bias. Considering the measured bone loss, criteria according to Albrektsson et al. [27] and success criteria on the implant level (pain, bone loss < 1.5 mm at first year, annual bone loss < 0.2 mm thereafter, radiolucency, mobility, infection) [26] were used to evaluate clinical evidence of successful osseointegration. Furthermore the following parameters were investigated regarding their impact on bone loss: (1) Gender (male vs female); (2) Age; (3) Implant region (anterior vs posterior); (4) Implant location (maxilla vs mandible); (5) Implant material (hybrid vs all-ceramics); (6) Length of the one-piece implant; (7) Length of the root portion; (8) Length of the abutment portion; (9) Size of implant surface area; (10) Bone quality documented by the surgeon [28]; (11) Difficulty of the operation according to the surgeon (grouped into: easy, intermediate and complicated); and (12) number of roots.
To assess peri-implant soft tissues, the modified plaque (mPI) and bleeding indices (mBI) according to Mombelli et al. [29] and the width of keratinized gingiva (KG) were adopted as criteria at follow-up examinations. Both for mPI (scale 0–3) and mBI (scale 0–3), 0 and 1 were counted as success, whilst 2 and 3 were considered not successful. The keratinized gingiva had to maintain a width of at least 1.5 mm [26] for a rating as success.
The Pink and White Esthetic Score (PES/WES) [30] and the modified United States Public Health Service (USPHS) criteria (Table 1) [31] were used to allow for standardized assessment of the esthetic outcome and a success rating at the prosthetic level. For both PES and WES, the threshold for clinical acceptability was set at 6 [30] and regarded successful in this study. The 7 modified USPHS criteria: (1) Fracture of veneering ceramic; (2) Fracture of framework; (3) Occlusal roughness; (4) Marginal integrity; (5) Contour of reconstruction; (6) Esthetics of reconstruction; and (7) Discoloration of reconstruction, were applied to every reconstruction and each rated as Alpha (A: within a range of excellence), Beta (B: minor deviations from the ideal), Charlie (C: clinically unacceptable defects that could be intraorally repaired to a clinically acceptable level), or Delta (D: irreparable problem of clinical relevance).
Patient-reported outcomes were assessed by applying VAS. Assessment of appearance and chewing ability was included in the evaluation. The patients were asked to label a point on a line that corresponded with their personal satisfaction. The line was 10 cm in length, without scale, and every millimeter corresponded to 1% of satisfaction (i.e., 10 cm corresponded to 100%). The left endpoint represented poor satisfaction (0%), whereas the point at the right end represented excellent satisfaction (100%). Finally, the patient’s markings were measured with a ruler. A rating of 80% or more resulted in a rating as success.
For a successful RAI, all of the 4 superordinate criteria: (1) Implant level; (2) Peri-implant soft tissues; (3) Prosthetic level; and (4) Patient satisfaction, had to be classified successful themselves, following the above defined criteria.
Surgeries of a single practitioner (D.H.) were evaluated. In order to reduce bias, follow-ups were not conducted by the surgeon, but by another independent practitioner (M.B.). In addition, MBL measurements were carried out by an independent private lecturer with experience in clinical studies. The data collection was therefore performed preferably independently and without financial support from the implant company. When compiling the examination parameters, care was taken to use parameters that were as objective and scientifically accepted as possible. Due to the small indication group for a treatment with a RAI, the objective to provide preliminary data and the scarcity of documented data sets in the literature, all possible data sets were evaluated, despite their heterogeneity.
Using 2-sided 95% confidence intervals, a total sample size of 31 RAIs was investigated. For the key clinical data (surgical and RAI-specific parameters, peri-implant soft tissue parameters, MBL, PES, WES, PES/WES), the means, minima, maxima, and standard deviations were calculated. The focus of statistical analysis was the progression of bone loss over time and parameters that may have an impact on it. To compensate for heterogeneous measurement intervals, the mean gradient of the bone loss during time interval 1 (from surgery until loading) and time interval 2 (from loading until examination) were individually computed for each patient. For final comparison, a dependent t-test for paired samples of the mean gradients in the different intervals was used.
To detect parameters potentially affecting the outcome, Welch’s t-tests on the data grouped by gender, implant region, implant location, implant material, difficulty of the operation and number of roots, were performed. Difficulty of the operation and number of roots were included in Welch’s t-tests, since only 2 different entries were made in the evaluation of the CRFs. The Pearson’s Correlation Coefficient between the total bone loss, age, length of the one-piece implant, root portion: Length, abutment portion: Length, implant surface, and bone quality were computed. Additionally, the Pearson’s Correlation was applied to investigate the coefficient among the total bone loss, esthetics (VAS), PES, WES, and PES/WES. Testing was adjusted to the quantity and quality of evaluable data (i.e., just 26 series of X-rays were evaluated). Survival and success rates were specified with calculation of percentages.
All statistical tests were performed with SciPy (SciPy developers), a Python-based ecosystem of open-source software for mathematics, science, and engineering. The level of significance was set at p < 0.05.

3. Results

3.1. Demographic Data and Additional Information

One hundred and seven RAI-surgeries were performed between September 2016 and August 2019 in the dental office of this study. Survival of implants was verified at follow-up examinations or, in case of a refused participation, by phone via the patients themselves or the records of the general dentists (see also Figure 1). A hundred and one root-analogues were still in situ at the time of the study after a mean observation period of 18.9 ± 2.4 months. Six RAIs failed, of which 4 did not show osseointegration in the healing period and 2 were lost after prosthetic delivery. This resulted in a survival rate of 94.4%.
A total of 28 patients, consisting of 11 males and 17 females, were recruited for follow-up examinations. One study participant was treated with two and another participant with three RAIs, resulting in a total number of 31 retrospectively examined and restored root-analogues (Table 2).
The mean age was 55.3 ± 14.2 years at surgeries and 56.6 ± 14.1 years at follow-up examinations. Implant placements of the study participants were performed between September 2016 and September 2018. Loading took place between August 2017 and August 2019. Twenty-five hybrid and 6 all-ceramics RAIs were restored with 29 single crowns and one three-unit fixed dental prostheses after a mean healing time of 6.6 ± 2.5 month. Follow-up examinations took place 17.5 ± 6.4 months after surgery and 10.8 ± 7.0 month after loading. Patient and RAI characteristics are shown in Table 3 and Table 4 including p-values related to the impact of the different parameters on MBL.

3.2. Implant Level

Of 31 RAIs, 26 were radiographically evaluated. Detailed information regarding the data used for measurements of the MBL are shown in Table 5. Before loading of the RAIs the mean MBL was calculated to be 0.82 ± 0.54 mm at T1 (T0-T1). At follow-up examinations the mean MBL was 1.20 ± 0.73 mm at T2 (T0-T2). Between loading (T1) and follow-up (T2), the MBL was 0.40 ± 0.41 mm (T1-T2). Bone resorption after surgery was recorded in every patient. Comparing T0-T1 with T1-T2 (Figure 4), a statistically significant reduced progression of bone resorption could be determined (p = 0.013).
Potential affecting parameters show no statistically significant influence on MBL and are shown in Table 3 and Table 4. The junction between the implant and abutment portions (JIAP) of the RAIs were planned iso- or subcrestally while designing the root-analogues prior to surgery (see also Table 5). Since the majority of JIAP were planned 1 mm subcrestally, a statistical evaluation of the influence of JIAP position on MBL was not reasonable. Adopting the afore explained criteria, 80.8% of the evaluable RAIs (n = 21) were successful regarding the implant level (Table 6). Pearson’s Correlation Coefficients are documented in Table 7.

3.3. Peri-Implant Soft Tissues

The level of presurgical planned restoration margins was ranging from 0.0 mm (n = 1), 1.0 mm (n = 13), 0.5–1.5 mm (n = 5) to ≥1.5 mm (n = 12) subgingival. All 31 root-analogues were evaluated regarding the peri-implant soft tissues at follow-up as shown in Table 8. The mean mPI was documented to be 0.6 ± 0.5, the mean mBI was 0.6 ± 0.7, and the mean KG was 3.9 ± 1.7 mm. This resulted in a success rate of 96.8% (n = 30) on the soft tissue level, as shown in Table 6.

3.4. Prosthetic Level

The total values of PES (mean 7.45 ± 1.50) and WES (mean 7.90 ± 1.74) resulted in a mean score of 15.35 ± 2.33 for PES/WES (Table 9). Including the criteria regarding the prosthetic level, a success rate of 83.3% (n = 25) was found (Table 6). Additionally, evaluation of the modified USPHS criteria for the analysis of single crowns and fixed dental prostheses was documented in detail in Table 10. Pearson’s Correlation Coefficients evaluating PES, WES, and PES/WES show no strong dependencies and can be found in Table 7.

3.5. Patient Satisfaction

The esthetic appearance of the reconstructions (n = 30) was rated 91.6 ± 17.5% on the VAS. A slightly lower mean value of 89.1 ± 18.9% was evaluated regarding the ability to chew. As previously defined, considering both parameters resulted in a success rate of 90.0% (n = 27; Table 6) regarding the patient satisfaction. Due to three participants, rating (1) The satisfaction with the appearance and/or (2) The ability to chew as unsatisfactory were counted as failure. Of those, two described discomfort while chewing and one was not pleased with the appearance of the single crown. Pearson’s Correlation Coefficients looking at esthetics (VAS) were again specified in Table 7.

3.6. Overall Survival and Success

Taking the predefined criteria in all 4 categories into account, a success rate of 64.5% (n = 20, based on 31 RAIs) and a survival rate of 94.4% (based on 107 RAIs) was determined 17.5 ± 6.4 months after RAI surgeries (Table 6).

4. Discussion

Immediate implantations with customized root-analogue implants show comparable results to conventional, screw-shaped implants after a short observation period. It seems that there are advantages in terms of soft tissues and esthetics, but disadvantages in terms of bone loss and restoration margins. However, the database is very small, and the calculations of success and survival rates should be interpreted with care. When discussing the present findings, the limitations of this study, especially regarding the limited sample size, should be kept in mind and conclusions mainly regarded as a tendency. A prospective study design should have been preferred. At the time this study was developed, available data needed to be evaluated retrospectively. However, due to the small indication group for treatment with a RAI and little data described in the literature, it was decided that the presented outcomes should be of interest to the field. Including this study there are too little studies available to be able to make a final comparison between RAIs and screw-shaped implants. Despite the fact that NDI Berlin ceased its business operations on 31 January 2020, the authors expect future developments and investigations regarding RAIs.
Studies on root-analogue implants and potential advantages appear repeatedly in the literature. As the procedure is not established in clinical routine, only case reports with different follow-up intervals [14,15,16,17,20,22] or literature reviews exploring the subject [33] are available. Recently, an article reviewing the historical development of RAIs was published [34]. The primary goal of this retrospective case series was to collect comprehensive data and give preliminary survival and success rates for rehabilitations supported by root-analogue implants. Therefore, regularly used scientific parameters, as described in a review in 2012 [26], were examined. Considering the extensive recruitment area and the referral structure of the dental office of the study, the largest possible patient group treated with the REPLICATE Immediate Tooth Replacement System was acquired for follow-ups. To the knowledge of the authors, such an extensive and detailed analysis of RAIs has not been described in the literature yet.
For screw-shaped implants, standardized manufacturer’s specifications (e.g., the pitch distance of the threads) are available for radiological analysis of bone loss. As RAIs are fully customized, there are no such standardized values. Therefore, the manufacturer was asked to give individual implant-specific details (e.g., implant length, abutment length, etc.) and precisely specified distances from distinctive RAI points (Figure 3b). This enabled the calculation of MBL as it is performed for screw-shaped implants [35,36]. A control group is missing due to the retrospective study design and high specificity of the treatment. The assessment of bone loss based on two-dimensional X-rays was applied in numerous precedent publications, but findings should be handled with care due to potential artefacts and dimensional limitations of the projection [37,38]. Because of the retrospective study design, no standardized radiographs with customized X-ray holders were available, and measurements should be interpreted with care.
The loss of bone was measured referring to the marginal bone level after installation of the RAIs (T0). Evaluating the radiographs, the absolute loss was measured, even if JIAP was located subcrestally and a bone loss was therefore already expected and considered. This corresponded to the transition between the polished and rough parts of the implant. Due to very homogeneous location of this transition zone (1 mm subcrestal in 73.1%), its influence on bone remodeling was not statistically evaluated. However, it can be assumed that the bone remodeling is more pronounced in these RAIs, as there are studies, in which screw-shaped implants with a subcrestal rough-smooth border show higher bone remodeling in the first 6 months after installation, than screw-shaped implants with an epicrestal (or close to the crest) rough-smooth border [39,40]. In reference to this, immediate implant placements with screw-shaped implants are usually also performed ~1 mm subcrestally [41], whereby MBL measurements are often carried out with regard to the rough-smooth border after completed healing and before loading. Using prosthetic delivery and loading of the implant as baseline, a mean of 0.40 ± 0.41 mm of bone was lost within a mean of 10.8 ± 7.0 month of service, ranging within the accepted amount of bone loss due to bone remodeling processes [42,43]. Applying the success criteria of the present study, this remodeling processes from installation of the RAIs to final loading were included and resulted in a success rate of 80.8% (n = 21) on the implant level. In this study, none of the patient-reported, surgical or RAI-specific parameters had a statistically significant influence on the MBL. However, regarding the limited sample size, the presented data should be interpreted with care. In conclusion, no advantages of RAIs compared to screw-shaped implants by means of bone level stability seem to be apparent. Bone loss observed appears to be comparable to conventional immediate implant surgery with screw-shaped implants and does not seem to further counteract the bony resorption or remodeling processes. These results were documented after a short observation period and should be interpreted as a tendency regarding the methodology. Nevertheless, as well with RAIs, greater bone loss seems to be expected during the healing phase compared to the phase after loading, as it is the case with screw-shaped implants.
To evaluate the success of implant-supported rehabilitations the assessment of the peri-implant soft tissues is inevitable. An evaluation of these, e.g., in form of bleeding on probing (BoP), in combination with peri-implant bone loss is necessary to rule out an undesirable complication of implants, peri-implantitis [1,44].
The RAIs included in the present investigation were mostly designed with subgingival cementation margins ranging from 0.5–1.5 mm (96.8%). But even if a subgingival restoration margin of more than 0.5 mm increases the risk of undetected cement [45], potentially resulting in gingival inflammation, this study revealed favorable results regarding peri-implant soft tissues. Only for one single RAI, a mBI > 2 has been documented. The buccal KG was >1.5 mm at all RAIs and despite oral hygiene was not always categorized optimal, the mPI never exceeded a rating of 2. In the short-term, it seems that the lower success rate regarding MBL detected at RAIs does not have a negative effect on the peri-implant soft tissue stability and health. This may be due to the transition of the abutment to the root portion (shape analogue and same width), compared to screw-shaped implants (strong, hardly cleanable, and probeable rejuvenation). In consequence, the fully anatomical imitation with RAIs might be considered advantageous regarding the susceptibility for peri-implantitis [46].
Finally, implants serve as support to the attempt to restore esthetics and function. To investigate the esthetics and possible complications, objective criteria were necessary to assess success at the prosthetic level. A feasible and comprehensive esthetic score for comparing results regarding rehabilitations with implants is constantly being discussed in the scientific community [47]. For an objective evaluation of the esthetic appearance, the PES/WES [30] as a reproducible instrument [48] and the modified USPHS criteria, which had already been used in other clinical studies to evaluate single crown restorations on implants [32], were used for classification. It should be considered that the PES/WES was originally developed for the evaluation of implant restorations in the esthetic area to be compared with contralateral natural teeth. In the present study, however, only 41.9% (n = 13) of the RAIs were in the esthetic area. Thirty-five and a half percent (n = 11) of the contralateral teeth were natural teeth, and 64.5% were restored. In such cases, results can be both false positive and false negative, therefore affecting the outcome. Due to the detailed sub-parameters within the PES/WES, however, it still provides a comprehensible and reproducible result. A mean of 15.35 ± 2.33 for PES/WES represents a favorable result compared to previous studies adopting these criteria [30,49]. According to the modified USPHS criteria, six out of seven criteria provided satisfactory results, predominantly being rated with no (A) or minor complications (B). However, marginal integrity was found to be noteworthy. Many of the restorations were documented to show a slightly soundable marginal gap and for some restorations the explorer even penetrated a significant crevice. Concerning marginal integrity, there seems to be a trend towards increased difficulty to provide conventionally copied RAIs with accurately fitting single crowns or fixed dental prostheses compared to other one-piece implants investigated in studies using the USPHS criteria [32]. Nevertheless, none of the restorations had to be replaced and, regarding the evaluation of the peri-implant soft tissues, does not seem to have a negative influence. A sufficient margin design is nevertheless desirable in order not to provide an exposed surface for possible complications, e.g., promotion of peri-implantitis. If a new fabrication of the restoration is indicated and the abutment portion of the respective RAIs has not been manipulated after the installation, a matching of the new impressions with the existing digital data sets of the abutment portion should be considered. Due to the difficulties described above, this might help to optimize the transition at the preparation margin.
Apart from the preferably objective evaluation of the procedure, each participant was asked to mark VAS for a subjective assessment. The individual sensation at rest or in function, i.e., when biting or chewing nutrition, was rated by the participants with an average of 89.1%. Furthermore, the personal esthetic perception was evaluated with an average of 91.6%. Two participants were not satisfied with “the ability to chew” and have described a different feeling compared to their natural teeth. No pain, mobility, or other clearly defined criteria for failure were evident. Twice, the appearance of the restorations in terms of color and translucency were rated below the defined threshold of 80%. This resulted in 3 unsatisfied patients, since one patient rated both parameters below the threshold for success. Two of these RAIs were located in the anterior region and 1 was located in the posterior region. They were evaluated with 12/12/13 points according to the PES/WES and received AAACBBA/CABCBAA/AAABAAA ratings according to the USPHS criteria. The below-average assessment of the PES/WES is thus consistent with the patient-specific assessment. An interpretation of the modified USPHS criteria can also be reconciled with it. This supports the assumption that the criteria used in this study represent a reproducible method for assessing esthetics and complications and are close to individual patient evaluations. Thus, the investigated success rate of 90.0% regarding patient satisfaction is sustained by the pre-discussed objective parameters. The esthetic deficits and marginal discrepancies can be corrected by making new restorations using new impressions. For this purpose, the existing digital data sets should be considered as mentioned above and an additional focus on fittings should be carried out before the final cementation.
Patient satisfaction, esthetics and durability of the prosthetic outcome, soft tissue stability and health, and susceptibility for bone resorptions were considered relevant parameters for the determination of implant success. In terms of MBL, no advantage was found in comparison to screw-shaped implants. The strengths of the procedure seem to be mainly in the esthetic result and maintenance of healthy peri-implant soft tissues. Combining the four applied criteria for success resulted in an overall success rate of 64.5%. This is within the range of success rates of other scientific articles that have classified the implant success based on a combination of 4 superordinate criteria [50,51,52]. It is well known and reported that overall success decreases with an increasing number of included criteria [26]. Most research is limited to an examination of the implant level and especially the MBL.
It seems that the present findings are in line with the observations by Esposito and collaborates, likewise reporting a reduced success rate but highly satisfying esthetic results for immediately installed implants [53,54]. In contrast to conventional procedures, installing screw-shaped implants, one potential benefit might be considered the circumstance that no further augmentation techniques, such as a connective tissue grafts or guided bone regeneration, were required to achieve a comparably and esthetically pleasing result. Nevertheless, prospective long-term data are necessary for a final evaluation of RAIs. Most importantly, the influence of JIAP location on marginal bone remodeling and a more reliable evaluation of the resorption processes (three-dimensional or standardized radiographs) would be of interest. In addition, the development of a standardized success score for implant-supported reconstructions would be helpful to compare the findings of different studies in a more comprehensive manner.
Finally, treatment with RAIs is only suitable for a small group of patients with extractions planned in the near future. The alveolar bone needs to be intact and no extensive osteolysis and/or inflammatory processes in the implant region can be present. If possible, artefact-causing reconstructions in CBCTs potentially resulting in inaccuracies when production of the RAIs, such as metal, should be removed in advance. In general, it requires a very cautious approach by an experienced surgeon and destruction of the surrounding tissues during extraction can make RAI installation impossible. In such a case, planning efforts prior to surgery were useless, and the about 15% higher costs compared to screw-shaped implants (including bone and soft tissue augmentations) cannot be justified.

5. Conclusions

Immediate installation of RAIs does not seem to counteract the known marginal bone resorption processes after tooth extraction when compared to immediate installation of screw-shaped implants reported in the literature. However, at least after a short-time observation period, RAIs were found to maintain peri-implant soft tissue conditions and resulted in a predictable and highly satisfying esthetic outcome. For a more reliable analysis, mid- to long-term prospective studies are required. Given the small indication group and the limited data and advantages, it seems that the application of RAIs bears no relation to necessary efforts and expenses so far. The calculated survival rate for RAIs (94.4%) within the collected follow-up data after less than two years should be viewed critically when comparing to a survival rate of 94.6% considering 10-year follow-up data of screw-shaped implants [1]. During the completion of this study, NDI Berlin ceased its business on 31 January 2020. This and the failure to establish RAIs in dentistry within several years can be an indicator for its not yet convincing results.

Author Contributions

Conceptualization, M.W.H.B., D.H., F.B. and B.C.S.; Data curation, M.W.H.B., D.H., C.W., P.S. and B.C.S.; Formal analysis, M.W.H.B., C.W., P.S., S.P. and B.C.S.; Investigation, M.W.H.B. and D.H.; Methodology, M.W.H.B., F.B., C.W., P.S., S.P. and B.C.S.; Project administration, M.W.H.B.; Resources, M.W.H.B., D.H., C.W. and P.S.; Software, C.W. and P.S.; Supervision, B.C.S.; Validation, M.W.H.B., D.H., F.B., C.W., P.S., S.P. and B.C.S.; Visualization, M.W.H.B., C.W., P.S. and B.C.S.; Writing—original draft, M.W.H.B.; Writing—review & editing, F.B., S.P. and B.C.S. All authors have read and agreed to the published version of the manuscript.

Funding

We acknowledge support from the German Research Foundation (DFG) and the Open Access Publication Funds of Charité—Universitätsmedizin Berlin.

Acknowledgments

This investigation was supported by clinical data from the dental office of Detlef Hildebrand in Berlin, Germany and product specific data provided by NDI Berlin in Berlin, Germany.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Moraschini, V.; Poubel, L.D.C.; Ferreira, V.F.; Barboza, E.D.S. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: A systematic review. Int. J. Oral Maxillofac. Surg. 2015, 44, 377–388. [Google Scholar] [CrossRef]
  2. Tan, W.L.; Wong, T.L.T.; Wong, M.C.M.; Lang, N.P. A systematic review of post-extractional alveolar hard and soft tissue dimensional changes in humans. Clin. Oral Implant. Res. 2011, 23, 1–21. [Google Scholar] [CrossRef]
  3. Bhola, M.; Neely, A.L.; Kolhatkar, S. Immediate Implant Placement: Clinical Decisions, Advantages, and Disadvantages. J. Prosthodont. 2008, 17, 576–581. [Google Scholar] [CrossRef]
  4. Esposito, M.; Grusovin, M.G.; Polyzos, I.P.; Felice, P.; Worthington, H.V. Timing of implant placement after tooth extraction: Immediate, immediate-delayed or delayed implants? A Cochrane systematic review. Eur. J. oral Implant. 2010, 3, 189–205. [Google Scholar]
  5. Clementini, M.; Tiravia, L.; De Risi, V.; Orgeas, G.V.; Mannocci, A.; De Sanctis, M. Dimensional changes after immediate implant placement with or without simultaneous regenerative procedures. J. Clin. Periodontol. 2015, 42, 666–677. [Google Scholar] [CrossRef]
  6. Arora, H.; Khzam, N.; Roberts, D.; Bruce, W.L.; Ivanovski, S. Immediate implant placement and restoration in the anterior maxilla: Tissue dimensional changes after 2-5 year follow up. Clin. Implant. Dent. Relat. Res. 2017, 19, 694–702. [Google Scholar] [CrossRef]
  7. Pietrokovski, J.; Massler, M. Alveolar ridge resorption following tooth extraction. J. Prosthet. Dent. 1967, 17, 21–27. [Google Scholar] [CrossRef]
  8. Hodosh, M.; Povar, M.; Shklar, G. The dental polymer implant concept. J. Prosthet. Dent. 1969, 22, 371–380. [Google Scholar] [CrossRef]
  9. Lundgren, D.; Rylander, H.; Anderssong, M.; Johansson, C.; Albrektsson, T. Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin. Oral Implant. Res. 1992, 3, 136–144. [Google Scholar] [CrossRef]
  10. Kohal, R.; Hürzeler, M.B.; Mota, L.F.; Klaus, G.; Caffesse, R.G.; Strub, J.R. Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys. Clin. Oral Implant. Res. 1997, 8, 386–392. [Google Scholar] [CrossRef]
  11. Kohal, R.; Klaus, G.; Gieloff, B.; Hürzeler, M.B.; Strub, J.R. Wurzelanaloge Titanimplantate (Bio-Design-Implantate) für die Sofortimplantation-Das Re-Implant-System. Implantologie 1996, 4, 99–115. [Google Scholar]
  12. Strub, J.R.; Klaus, G.; Ferraresso, F.; Kohal, R. The Re Implant® System for Immediate Implant Placement. J. Esthet. Restor. Dent. 1997, 9, 187–196. [Google Scholar] [CrossRef] [PubMed]
  13. Kohal, R.; Klaus, G.; Strub, J.R. Klinische Untersuchung eines neuen dentalen Sofort-Implantatsystems. Das ReImplant-System. Dtsch. Zahnärztliche Z. 2002, 57, 495–497. [Google Scholar]
  14. Pirker, W.; Kocher, A. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int. J. Oral Maxillofac. Surg. 2008, 37, 293–295. [Google Scholar] [CrossRef]
  15. Pirker, W.; Kocher, A. Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int. J. Oral Maxillofac. Surg. 2009, 38, 1127–1132. [Google Scholar] [CrossRef]
  16. Pirker, W.; Kocher, A. Root analog zirconia implants: True anatomical design for molar replacement—A case report. Int. J. Periodontics Restor. Dent. 2011, 31, 663–668. [Google Scholar]
  17. Pirker, W.; Wiedemann, D.; Lidauer, A.; Kocher, A. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-up. Int. J. Oral Maxillofac. Surg. 2011, 40, 212–216. [Google Scholar] [CrossRef]
  18. Moin, D.A.; Hassan, B.; Mercelis, P.; Wismeijer, D. Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology. Clin. Oral Implant. Res. 2011, 24, 25–27. [Google Scholar] [CrossRef]
  19. Mangano, C.; Cirotti, B.; Sammons, R.L.; Mangano, C. Custom-made, root-analogue direct laser metal forming implant: A case report. Lasers Med Sci. 2012, 27, 1241–1245. [Google Scholar] [CrossRef]
  20. Pour, R.; Randelzhofer, P.; Edelhoff, D.; Prandtner, O.; Rafael, C.; Liebermann, A. Innovative Single-Tooth Replacement with an Individual Root-Analog Hybrid Implant in the Esthetic Zone: Case Report. Int. J. Oral Maxillofac. Implant. 2017, 32. [Google Scholar] [CrossRef]
  21. Beuer, F.; Groesser, J.; Schweiger, J.; Hey, J.; Güth, J.-F.; Stimmelmayr, M. The Digital One-Abutment/One-Time Concept. A Clinical Report. J. Prosthodont. 2015, 24, 580–585. [Google Scholar] [CrossRef] [PubMed]
  22. Schubert, O.; Beuer, F.; Güth, J.-F.; Nold, E.; Edelhoff, D.; Metz, I. Two digital strategies in modern implantology—Root-analogue implants and the digital one-abutment/one-time concept. Int. J. Comput. Dent. 2018, 21, 115–131. [Google Scholar] [PubMed]
  23. Sanz, M.; Noguerol, B.; Sanz-Sánchez, I.; Hammerle, C.H.F.; Schliephake, H.; Renouard, F.; Sicilia, A.; Steering Committee; Cordaro, L.; Jung, R. European Association for Osseointegration Delphi study on the trends in Implant Dentistry in Europe for the year 2030. Clin. Oral Implant. Res. 2019, 30, 476–486. [Google Scholar] [CrossRef]
  24. Muska, E.; Walter, C.; Knight, A.; Taneja, P.; Bulsara, Y.; Hahn, M.; Desai, M.; Dietrich, T. Atraumatic vertical tooth extraction: A proof of principle clinical study of a novel system. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 2013, 116, e303–e310. [Google Scholar] [CrossRef] [PubMed]
  25. Okada, H.; Takahashi, K.; Ogura, N.; Tomoki, R.; Ito, K.; Kondoh, T. Plasma rich in growth factors stimulates proliferation, migration, and gene expression associated with bone formation in human dental follicle cells. J. Dent. Sci. 2016, 11, 245–252. [Google Scholar] [CrossRef] [Green Version]
  26. Papaspyridakos, P.; Chen, C.-J.; Singh, M.; Weber, H.-P.; O Gallucci, G. Success criteria in implant dentistry: A systematic review. J. Dent. Res. 2011, 91, 242–248. [Google Scholar] [CrossRef]
  27. Albrektsson, T.; Zarb, G.; Worthington, P.; Eriksson, A.R. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int. J. Oral Maxillofac. Implant. 1986, 1, 11–25. [Google Scholar]
  28. Bra-Nemark, P.-I.; Zarb, G.A.; Albrektsson, T.; Rosen, H.M. Tissue-Integrated Prostheses. Osseointegration in Clinical Dentistry. Plast. Reconstr. Surg. 1986, 77, 496–497. [Google Scholar] [CrossRef]
  29. Mombelli, A.; Oosten, M.A.C.; Schürch, E.; Land, N.P.; Lang, N.P. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol. Immunol. 1987, 2, 145–151. [Google Scholar] [CrossRef]
  30. Belser, U.C.; Grütter, L.; Vailati, F.; Bornstein, M.M.; Weber, H.-P.; Buser, D. Outcome Evaluation of Early Placed Maxillary Anterior Single-Tooth Implants Using Objective Esthetic Criteria: A Cross-Sectional, Retrospective Study in 45 Patients With a 2- to 4-Year Follow-Up Using Pink and White Esthetic Scores. J. Periodontol. 2009, 80, 140–151. [Google Scholar] [CrossRef]
  31. Schmalz, G.; Ryge, G. Reprint of Criteria for the clinical evaluation of dental restorative materials. Clin. Oral Investig. 2005, 9, 215–232. [Google Scholar] [CrossRef] [PubMed]
  32. Spies, B.C.; Kohal, R.; Balmer, M.; Vach, K.; Jung, R.E. Evaluation of zirconia-based posterior single crowns supported by zirconia implants: Preliminary results of a prospective multicenter study. Clin. Oral Implant. Res. 2016, 28, 613–619. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  33. Pessanha-Andrade, M.; Sordi, M.B.; Henriques, B.; Silva, F.; Teughels, W.; Souza, J.C. Custom-made root-analogue zirconia implants: A scoping review on mechanical and biological benefits. J. Biomed. Mater. Res. Part B Appl. Biomater. 2018, 106, 2888–2900. [Google Scholar] [CrossRef] [PubMed]
  34. Pour, R.S.; Rafael, C.F.; Engler, M.L.P.D.; Edelhoff, D.; Klaus, G.; Prandtner, O.; Berthold, M.; Liebermann, A. Historical development of root analogue implants: A review of published papers. Br. J. Oral Maxillofac. Surg. 2019, 57, 496–504. [Google Scholar] [CrossRef] [PubMed]
  35. Galindo-Moreno, P.; León-Cano, A.; Ortega-Oller, I.; Monje, A.; O′valle, F.; Catena, A. Marginal bone loss as success criterion in implant dentistry: Beyond 2 mm. Clin. Oral Implant. Res. 2014, 26, e28–e34. [Google Scholar] [CrossRef]
  36. Degidi, M.; Daprile, G.; Piattelli, A. Marginal bone loss around implants with platform-switched Morse-cone connection: A radiographic cross-sectional study. Clin. Oral Implant. Res. 2016, 28, 1108–1112. [Google Scholar] [CrossRef]
  37. A Malloy, K.; Wadhwani, C.; McAllister, B.; Wang, M.; A Katancik, J. Accuracy and Reproducibility of Radiographic Images for Assessing Crestal Bone Height of Implants Using the Precision Implant X-ray Locator (PIXRL) Device. Int. J. Oral Maxillofac. Implant. 2017, 32, 830–836. [Google Scholar] [CrossRef] [Green Version]
  38. Walton, T.R.; Layton, D. Intra- and inter-examiner agreement when assessing radiographic implant bone levels: Differences related to brightness, accuracy, participant demographics and implant characteristics. Clin. Oral Implant. Res. 2018, 29, 756–771. [Google Scholar] [CrossRef]
  39. Hartman, G.A.; Cochran, D.L. Initial Implant Position Determines the Magnitude of Crestal Bone Remodeling. J. Periodontol. 2004, 75, 572–577. [Google Scholar] [CrossRef]
  40. Hermann, J.S.; Cochran, D.L.; Nummikoski, P.V.; Buser, D. Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible. J. Periodontol. 1997, 68, 1117–1130. [Google Scholar] [CrossRef]
  41. Capelli, M.; Testori, T.; Galli, F.; Zuffetti, F.; Motroni, A.; Weinstein, R.; Del Fabbro, M. Implant–Buccal Plate Distance as Diagnostic Parameter: A Prospective Cohort Study on Implant Placement in Fresh Extraction Sockets. J. Periodontol. 2013, 84, 1768–1774. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  42. Misch, C.E.; Perel, M.L.; Wang, H.-L.; Sammartino, G.; Galindo-Moreno, P.; Trisi, P.; Steigmann, M.; Rebaudi, A.; Palti, A.; Pikos, M.A.; et al. Implant Success, Survival, and Failure: The International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference. Implant. Dent. 2008, 17, 5–15. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  43. Pjetursson, B.E.; Zarauz, C.; Strasding, M.; Sailer, I.; Zwahlen, M.; Zembic, A. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin. Oral Implant. Res. 2018, 29, 160–183. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Heitz-Mayfield, L.J.A.; Aaboe, M.; Araujo, M.; Carrión, J.B.; Cavalcanti, R.; Cionca, N.; Cochran, D.; Darby, I.; Funakoshi, E.; Gierthmuehlen, P.C.; et al. Group 4 ITI Consensus Report: Risks and biologic complications associated with implant dentistry. Clin. Oral Implant. Res. 2018, 29, 351–358. [Google Scholar] [CrossRef] [Green Version]
  45. Linkevicius, T.; Vindasiute, E.; Puisys, A.; Linkeviciene, L.; Maslova, N.; Puriene, A. The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study. Clin. Oral Implant. Res. 2012, 24, 71–76. [Google Scholar] [CrossRef]
  46. Hashim, D.; Cionca, N.; Combescure, C.; Mombelli, A. The diagnosis of peri-implantitis: A systematic review on the predictive value of bleeding on probing. Clin. Oral Implant. Res. 2018, 29, 276–293. [Google Scholar] [CrossRef] [Green Version]
  47. Arunyanak, S.P.; Pollini, A.; Ntounis, A.; Morton, D. Clinician assessments and patient perspectives of single-tooth implant restorations in the esthetic zone of the maxilla: A systematic review. J. Prosthet. Dent. 2017, 118, 10–17. [Google Scholar] [CrossRef]
  48. Tettamanti, S.; Millen, C.; Gavric, J.; Buser, D.; Belser, U.C.; Bragger, U.; Wittneben, J.-G. Esthetic Evaluation of Implant Crowns and Peri-Implant Soft Tissue in the Anterior Maxilla: Comparison and Reproducibility of Three Different Indices. Clin. Implant. Dent. Relat. Res. 2015, 18, 517–526. [Google Scholar] [CrossRef] [Green Version]
  49. Gallucci, G.O.; Grütter, L.; Nedir, R.; Bischof, M.; Belser, U.C. Esthetic outcomes with porcelain-fused-to-ceramic and all-ceramic single-implant crowns: A randomized clinical trial. Clin. Oral Implant. Res. 2010, 22, 62–69. [Google Scholar] [CrossRef]
  50. Gallucci, G.O.; Doughtie, C.B.; Hwang, J.W.; Fiorellini, J.P.; Weber, H.-P. Five-year results of fixed implant-supported rehabilitations with distal cantilevers for the edentulous mandible. Clin. Oral Implant. Res. 2009, 20. [Google Scholar] [CrossRef]
  51. Romeo, E.; Lops, D.; Margutti, E.; Ghisolfi, M.; Chiapasco, M.; Vogel, G. Long-term survival and success of oral implants in the treatment of full and partial arches: A 7-year prospective study with the ITI dental implant system. Int. J. Oral Maxillofac. Implant. 2004, 19, 247–259. [Google Scholar]
  52. Romeo, E.; Tomasi, C.; Finini, I.; Casentini, P.; Lops, D. Implant-supported fixed cantilever prosthesis in partially edentulous jaws: A cohort prospective study. Clin. Oral Implant. Res. 2009, 20, 1278–1285. [Google Scholar] [CrossRef] [PubMed]
  53. Esposito, M.; Grusovin, M.G.; Polyzos, I.P.; Felice, P.; Worthington, H.V. Interventions for replacing missing teeth: Dental implants in fresh extraction sockets (immediate, immediate-delayed and delayed implants). Cochrane Database Syst. Rev. 2010, 9, CD005968. [Google Scholar] [CrossRef] [PubMed]
  54. Esposito, M.; Zucchelli, G.; Cannizzaro, G.; Checchi, L.; Barausse, C.; Trullenque-Eriksson, A.; Felice, P. Immediate, immediate-delayed (6 weeks) and delayed (4 months) post-extractive single implants: 1-year post-loading data from a randomised controlled trial. Eur. J. Oral Implant. 2017, 10, 11–26. [Google Scholar]
Figure 1. Flow diagram regarding study design and distribution; n: number of root-analogues/evaluated data within the different stages of the present study.
Figure 1. Flow diagram regarding study design and distribution; n: number of root-analogues/evaluated data within the different stages of the present study.
Jcm 09 02346 g001
Figure 2. Exemplary workflow of a restoration with the REPLICATE Immediate Tooth Replacement System: (a) Tooth (24/UL4) not maintainable with longitudinal fracture; (b) Inserted Benex Extraction-System (Benex Extraction-System, Helmut Zepf Medizintechnik GmbH, Seitlingen-Oberflacht, Germany); (c) extracted root and Try-In; (d) Try-In in the alveolus with Plasma Rich Growth Factors (PRGF) at the buccal junction; (e) root-analogue implant (RAI) in its opened sterile packaging; (f) RAI with placement assistance compared to the Try-In; (g) installation of the RAI; (h) Temporary Protective Covers (TPC) before bonding; (i) bonded TPC as load protection; (j) healed RAI with interfering gingiva; (k) contralateral natural teeth; (l) restored RAI and adjacent teeth.
Figure 2. Exemplary workflow of a restoration with the REPLICATE Immediate Tooth Replacement System: (a) Tooth (24/UL4) not maintainable with longitudinal fracture; (b) Inserted Benex Extraction-System (Benex Extraction-System, Helmut Zepf Medizintechnik GmbH, Seitlingen-Oberflacht, Germany); (c) extracted root and Try-In; (d) Try-In in the alveolus with Plasma Rich Growth Factors (PRGF) at the buccal junction; (e) root-analogue implant (RAI) in its opened sterile packaging; (f) RAI with placement assistance compared to the Try-In; (g) installation of the RAI; (h) Temporary Protective Covers (TPC) before bonding; (i) bonded TPC as load protection; (j) healed RAI with interfering gingiva; (k) contralateral natural teeth; (l) restored RAI and adjacent teeth.
Jcm 09 02346 g002
Figure 3. Exemplary series of X-rays for marginal bone loss (MBL) measurement: (a) visualized RAI construction by Natural Dental Implants (NDI); (b) initial image for measurement of bone loss; (c) X-ray post-implantation; (d) X-ray after healing time (before impression for loading); (e) X-ray after loading.
Figure 3. Exemplary series of X-rays for marginal bone loss (MBL) measurement: (a) visualized RAI construction by Natural Dental Implants (NDI); (b) initial image for measurement of bone loss; (c) X-ray post-implantation; (d) X-ray after healing time (before impression for loading); (e) X-ray after loading.
Jcm 09 02346 g003
Figure 4. (a) Bone loss gradient in mm/day from surgery to loading (T0-T1; Time Interval (1) and loading to examination (T1-T2; Time Interval (2); (b) visualization of the box plot without any possible axis labeling based on the calculation of the gradients due to heterogeneous follow-up intervals. Created with SciPy (SciPy developers).
Figure 4. (a) Bone loss gradient in mm/day from surgery to loading (T0-T1; Time Interval (1) and loading to examination (T1-T2; Time Interval (2); (b) visualization of the box plot without any possible axis labeling based on the calculation of the gradients due to heterogeneous follow-up intervals. Created with SciPy (SciPy developers).
Jcm 09 02346 g004
Table 1. Modified United States Public Health Service (USPHS) criteria for the analysis of single crowns and fixed dental prostheses [31,32].
Table 1. Modified United States Public Health Service (USPHS) criteria for the analysis of single crowns and fixed dental prostheses [31,32].
Alpha (A)Bravo (B)Charlie (C)Delta (D)
Fracture of veneering ceramicNo fractureMinor chipping (polishable)Major chipping (up to framework)Fracture (loss of reconstruction)
Fracture of frameworkNo fracture--Fracture (loss of reconstruction)
Occlusal roughnessNo roughnessSlight roughness
(Ø < 2 mm)
Obvious roughness
(Ø > 2 mm)
Reconstruction needs to be replaced
Marginal integrityNo visible or soundable gapMarginal gap slightly soundableExplorer penetrates a significant creviceReconstruction needs to be replaced
Contour of reconstructionPerfectly contouredSlightly under-/overcountouredPronounced under-/overcontouredReconstruction inacceptable
Esthetics of reconstructionGood estheticsSlight mismatch in colorSevere color mismatchReconstruction inacceptable
Discoloration of reconstructionNo discolorationsdiscoloration
Table 2. RAI distribution and region.
Table 2. RAI distribution and region.
Posterior (P)Anterior (A)Posterior (P)
FDI1716151413121121222324252627
n (maxilla)11300165013100
n (mandible)02210000001300
FDI4746454443424131323334353637
n (region)10138
FDI: Scheme according to the World Dental Federation; n: number of placed root-analogues in the respective position or region (anterior or posterior).
Table 3. Patient characteristics and p-values for investigated influence on MBL.
Table 3. Patient characteristics and p-values for investigated influence on MBL.
ParameterFrequency n (%)p-Value
Gender0.260
female17 (61)
male11 (39)
Age0.869
mean (in years)55.3/56.6 1
range (in years)31–82/33–83 1
Implant region0.571
anterior13 (42)
posterior18 (58)
Implant location0.691
maxilla22 (71)
mandible9 (29)
Implant material0.483
hybrid25 (81)
all-ceramics6 (19)
Bone quality0.898
I1 (3)
II10 (32)
III14 (45)
IV6 (19)
Difficulty of the operation0.690
easy0 (0)
intermediate21 (68)
complicated10 (32)
Number of roots0.091
single rooted25 (81)
multi rooted6 (19)
1 first data concerning the date of surgery, second data concerning the date of examination.
Table 4. RAI characteristics and p-values for investigated influence on MBL.
Table 4. RAI characteristics and p-values for investigated influence on MBL.
Length of the One-Piece Implant
(in mm)
Root Portion: Length
(in mm)
Abutment Portion: Length
(in mm)
Implant Surface
(in cm2)
n31313125 1
Min12.417.493.18101
Max26.3014.7914.86442
SD3.121.862.4183
Mean19.1910.968.43213
p-values0.7090.8700.7170.078
n: number of root-analogues included in calculations; 1 the implant surfaces of 6 all-ceramic RAIs could not be provided by NDI Berlin.
Table 5. Marginal bone loss and time difference from surgery (T0) to loading (T1) and the follow-up examination (T2).
Table 5. Marginal bone loss and time difference from surgery (T0) to loading (T1) and the follow-up examination (T2).
RAIsSurgery (T0)
(in mm)
Loading (T1)
(in mm)
Examination (T2)
(in mm)
T0-T1
(in Days)
T1-T2
(in Days)
T0-T2
(in Days)
JIAP
(in mm)
10.00−0.50−1.30276350626−1.00
20.00−1.35−1.55276350626−1.00
30.00−0.20−0.50260350610−1.00
40.00−1.10−1.302812725530.00
50.00−0.90−0.90155418573−1.50
60.00−1.10−2.2086509595−1.00
70.00−0.50−0.7586663749−1.00
80.00−1.10−1.25153750903−1.00
90.00−0.30−0.4512634160−1.00
100.00−0.75−1.00254358612−1.00
110.00−1.70−1.703432606030.00
120.00−0.60−0.85291369660−1.00
130.00−1.70−2.8592488580−1.00
140.00−0.75−1.40132182314−1.00
150.00−0.95−2.55266503769−0.75
160.00−0.55−0.8522832260−1.00
170.00−0.40−0.55151107258−1.00
180.00−0.30−0.7513534169−1.00
190.00−0.40−0.60182338520−1.00
200.00−0.80−1.1512450174−1.00
210.00−0.35−0.5097459556−1.00
220.00−2.50−2.9099598697−1.25
230.00−0.45−1.4099598697−1.25
240.00−0.80−0.80102584686−1.00
250.00−0.65−1.10916367270.00
260.00−0.15−0.15141288429−1.00
Min−0.15−0.1586.0032.00160.00−1.5
Max−2.50−2.90343.00750.00903.000.00
SD0.540.7378.91208.77202.030.36
Mean−0.82−1.20173.56368.46542.54−0.91
JIAP: the prior to surgery planned iso- or subcrestal junction between the implant and abutment portion of the RAIs; only 26 of 31 RAIs showed a retrospectively evaluable series of X-rays at follow-up; negative values indicate a loss of bone in relation to marginal bone levels at surgery.
Table 6. Success criteria based on included parameters.
Table 6. Success criteria based on included parameters.
Implant LevelSoft tissue ParametersProsthetic LevelPatient SatisfactionOverall Rating
n%n%n%n%n%
n2683.931100.030100.030100.031100.0
Success2180.83096.82583.32790.02064.5
n: number of evaluated RAIs, respectively, reconstructions; only 26 RAIs could be included in the evaluation of MBL; 31 RAIs were investigated regarding soft tissue parameters; due to 29 single crowns and 1 fixed dental prosthesis, the number of investigated reconstructions and patient satisfaction was 30.
Table 7. Pearson’s Correlation Coefficients.
Table 7. Pearson’s Correlation Coefficients.
Esthetic (VAS)PESPES/WESWESTotal Bone Loss (T0-T2)
Esthetic (VAS)1.0000000.3357670.3586910.1642370.074137
PES0.3357671.0000000.6665820.137687−0.089390
PES/WES0.3586910.6665821.0000000.6853100.012887
WES0.1642370.1376870.6853101.0000000.096554
Total bone loss (T0-T2)0.074137−0.0893900.0128870.0965541.000000
Table 8. Peri-implant soft tissue parameters.
Table 8. Peri-implant soft tissue parameters.
mPImBIKG (in mm)
n313131
Min001.5
Max139
SD0.50.71.7
Mean0.60.63.9
n: number of included root-analogues in calculations; mPI: the modified plaque index [29] mBI: the modified bleeding index [29]; KG: width of buccal keratinized gingiva.
Table 9. Detailed Pink Esthetic Score (PES) and White Esthetic Score (WES) for each RAI investigated [30].
Table 9. Detailed Pink Esthetic Score (PES) and White Esthetic Score (WES) for each RAI investigated [30].
PESWES
RAIsMesial PapillaDistal PapillaCurvature of Facial MucosaLevel of Facial MucosaRoot Convexity/Soft Tissue Color and TextureTotal PESTooth FormOutline/VolumeColor (Hue/Value)Surface TextureTranslucency/CharacterizationTotal WESTotal PES + WES
1122128222221018
2122128222221018
322111711222815
4222221022212919
512121711111512
622211811111513
722211811121614
800221511221712
911222822112816
1021222922111716
1121222922111716
1222111711211613
1322122911112615
1412111611222814
1511111511122712
16102126222221016
1721222922121817
1802212721112714
1920111511111510
20112228222221018
21102227222221017
22111126222221016
23111126222221016
2411221711222815
25122229222221019
2600112422122913
2721221811211614
28222219222221019
2912221822121816
3022122911121615
3122221922122918
Min00111411111510
Max2222210222221019
SD0.660.750.490.510.511.500.500.510.510.490.501.742.33
Mean1.351.351.651.551.557.451.581.551.521.651.617.9015.35
Table 10. Results applying modified USPHS criteria as mentioned in Table 1 at follow-up.
Table 10. Results applying modified USPHS criteria as mentioned in Table 1 at follow-up.
Alpha (A)Bravo (B)Charlie (C)Delta (D)
Fracture of veneering ceramic29 (96.7%)01 (3.3%)0
Fracture of framework30 (100.0%)000
Occlusal roughness26 (86.7%)4 (13.3%)00
Marginal integrity9 (30.0%)17 (56.7%)4 (13.3%)0
Contour of reconstruction22 (73.3%)8 (26.7%)00
Esthetics of reconstruction24 (80.0%)6 (20.0%)00
Discoloration of reconstruction30 (100.0%)0
30 included restorations due to 29 single crowns and 1 three-unit fixed dental prostheses.

Share and Cite

MDPI and ACS Style

Böse, M.W.H.; Hildebrand, D.; Beuer, F.; Wesemann, C.; Schwerdtner, P.; Pieralli, S.; Spies, B.C. Clinical Outcomes of Root-Analogue Implants Restored with Single Crowns or Fixed Dental Prostheses: A Retrospective Case Series. J. Clin. Med. 2020, 9, 2346. https://doi.org/10.3390/jcm9082346

AMA Style

Böse MWH, Hildebrand D, Beuer F, Wesemann C, Schwerdtner P, Pieralli S, Spies BC. Clinical Outcomes of Root-Analogue Implants Restored with Single Crowns or Fixed Dental Prostheses: A Retrospective Case Series. Journal of Clinical Medicine. 2020; 9(8):2346. https://doi.org/10.3390/jcm9082346

Chicago/Turabian Style

Böse, Mats Wernfried Heinrich, Detlef Hildebrand, Florian Beuer, Christian Wesemann, Paul Schwerdtner, Stefano Pieralli, and Benedikt Christopher Spies. 2020. "Clinical Outcomes of Root-Analogue Implants Restored with Single Crowns or Fixed Dental Prostheses: A Retrospective Case Series" Journal of Clinical Medicine 9, no. 8: 2346. https://doi.org/10.3390/jcm9082346

APA Style

Böse, M. W. H., Hildebrand, D., Beuer, F., Wesemann, C., Schwerdtner, P., Pieralli, S., & Spies, B. C. (2020). Clinical Outcomes of Root-Analogue Implants Restored with Single Crowns or Fixed Dental Prostheses: A Retrospective Case Series. Journal of Clinical Medicine, 9(8), 2346. https://doi.org/10.3390/jcm9082346

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop