Next Article in Journal
Fast and Accurate Pneumocystis Pneumonia Diagnosis in Human Samples Using a Label-Free Plasmonic Biosensor
Next Article in Special Issue
Cellular Responses of Human Lymphatic Endothelial Cells to Carbon Nanomaterials
Previous Article in Journal
Dendrimer Nanodevices and Gallic Acid as Novel Strategies to Fight Chemoresistance in Neuroblastoma Cells
Previous Article in Special Issue
A Comparative Assessment of Mechanisms and Effectiveness of Radiosensitization by Titanium Peroxide and Gold Nanoparticles
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review

1
School of Metallurgical Engineering, Xi’an University of Architecture and Technology, No.13 Yanta Road, Xi’an 710055, China
2
School of Aeronautical Materials Engineering, Xi’an Aeronautical Polytechnic Institute, Xi’an 710089, China
3
State Key Laboratory of Metal Matrix Composites, School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
4
Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong 999077, China
5
National Engineering Research Center for Nanotechnology (NERCN), 28 East JiangChuan Road, Shanghai 200241, China
*
Authors to whom correspondence should be addressed.
Qingge Wang and Peng Zhou contribute equally.
Nanomaterials 2020, 10(6), 1244; https://doi.org/10.3390/nano10061244
Submission received: 5 May 2020 / Revised: 30 May 2020 / Accepted: 22 June 2020 / Published: 26 June 2020
(This article belongs to the Special Issue Non-cytotoxic Nanoparticles)

Abstract

:
The propose of this review was to summarize the advances in multi-scale surface technology of titanium implants to accelerate the osseointegration process. The several multi-scaled methods used for improving wettability, roughness, and bioactivity of implant surfaces are reviewed. In addition, macro-scale methods (e.g., 3D printing (3DP) and laser surface texturing (LST)), micro-scale (e.g., grit-blasting, acid-etching, and Sand-blasted, Large-grit, and Acid-etching (SLA)) and nano-scale methods (e.g., plasma-spraying and anodization) are also discussed, and these surfaces are known to have favorable properties in clinical applications. Functionalized coatings with organic and non-organic loadings suggest good prospects for the future of modern biotechnology. Nevertheless, because of high cost and low clinical validation, these partial coatings have not been commercially available so far. A large number of in vitro and in vivo investigations are necessary in order to obtain in-depth exploration about the efficiency of functional implant surfaces. The prospective titanium implants should possess the optimum chemistry, bionic characteristics, and standardized modern topographies to achieve rapid osseointegration.

1. Introduction

In recent decades, the worldwide demand for dental and orthopedic implants has grown steadily, reaching approximately $45.5 billion sales in 2014 [1,2,3]. Brånemark [4] studied the osseointegration process and applied the first dental implant in the 1960s. Since then, the detailed study and development of dental and orthopedic implants have been continued. Long-term follow-up for the different types of implants in patients has been adequately reported in the literature [5,6,7,8,9,10]. The clinical success rate of dental implants was reported to be more than 87.8% over a follow-up period of 36 years, which is mainly related to early bone regeneration [5]. Dental implant design and its topography are among the vital factors influencing its early osseointegration process. Since the 1970s, dental implant shapes have transformed from hexagonal to conical connections and they are usually designed as rough titanium surfaces [1,5,11]. The efficiency of the connection method directly affects the long-term stability of the bone tissue in the neck of the dental implant. The long-term stability of conical connections is better than that of hexagonal connections. In addition, the rough surface increases the contact area between the implant and the osteoblasts, thus accelerating bone healing. It also reduces bone resorption by increasing the bonding strength and thus improving the interfacial stress distribution, which in turn reduces the healing time in dental implants [11,12]. Two types of bone to implant surface interactions are observed in the initial stages of osseointegration. The first type involves a fibrous soft tissue capsule formation, and if it does not achieve the proper fixation with the surrounding bone, it will probably lead to implant failure. The second type, associated with the direct interaction of bone with the implant surface, is defined as osseointegration [1]. It is generally recognized that high fixation is one of the prerequisite parameters for successful long-term implantation [13]. The rate of osseointegration and the percentage of bone-to-implant contact (BIC) are highly dependent on the surface properties [14,15,16]. Various parameters such as chemical composition, surface energy, wettability (hydrophobicity/hydrophilicity), roughness, topography, and surface morphology play crucial roles in adhesion and the survival of cells [17,18]. Usually, materials with excellent biological and mechanical properties such as commercially pure titanium (CP Ti), Ti-6Al-4V, and zirconia have been previously used in dental and orthopedic implants [19,20,21,22,23,24].
Considering the non-toxic nature and biocompatibility characteristics, titanium is one of the best choices in implant applications. Titanium shows a vast number of remarkable properties, for instance, high fatigue and corrosion resistance in biological fluids [25]. Furthermore, among various Ti alloys, the β-type alloys reveal lower elastic moduli [26,27], excellent corrosion resistance [28,29], and improved biocompatibility [30,31,32,33,34,35,36,37,38,39]. However, the bio-inertness of Ti alloys leads to an extended osseointegration time with bone. In order to overcome this limitation, surface treatment technologies can be used to attain bioactive surfaces on Ti substrates [40,41,42,43]. The macro-scale, micro-scale, and nano-scale morphology of the implant surfaces have a crucial influence on the early bone formation and fixation [16,44,45]. Most titanium implant surfaces with certain roughness characteristics were fabricated through mixed technologies (e.g., grit-blasting, acid-etching). In addition, the latest research literature concentrates on macro-, micro-, and nano-scale surface modification through different methods with promoted osseointegration responses [42,46,47]. Meanwhile, the multi-scaled morphologies enhance protein adsorption and stimulate osteogenic cell migration in order to accelerate the osseointegration period [48]. In addition, periodontitis (CP) and coronary heart disease (CHD) patients have bigger challenges regarding dental implant implantation, as these patients are more likely to develop peri-implantitis. In clinical studies, asymmetric dimethylarginine (ADMA) [49], endothelin-1(ET-1) concentrations [50], and vitamin D [51] have nonnegligible effects on CP and CHD. These studies suggested that patients suffering from CP and CHD have higher salivary levels of ET-1 and lower serum levels of vitamin D than healthy control subjects [50,51]. In a multivariate model, the significant predictors of salivary ADMA levels were hs-C-reactive protein [49]. Therefore, the exact role of the potential benefits of ADMA, ET-1, and vitamin D should be further studied in detail.
The purpose of this article is to report the state of the art on the multi-scale technological advancements of titanium implant surfaces to accelerate osseointegration. This review mainly focuses on innovative physicochemical procedures in multi-scale-based techniques. The physical and chemical characteristics such as wettability, roughness, and bioactivity of titanium implants in relation to biological performance is fully discussed. In this regard, the multi-scale functional coatings have the potential to increase the protein adsorption and speed up the osteogenic cell migration, angiogenesis and the early bone formation and its mineralization. Nevertheless, the optimum process parameters for various technologies still need to be clarified and will be discussed in detail in this article.

1.1. Chemical Composition and Wettability

In general, CP Ti and its alloys are used to fabricate dental implant fixtures [52]. Meanwhile, the choice of titanium and its alloys as an implant material depends on the high biocompatibility, corrosion resistance, strength, and the osseointegration function [53]. In addition, the biocompatibility of titanium-based alloys is determined by its composition, patient health conditions, and implanting position. Compared with other metallic systems, pure titanium and its alloys are clinically preferred because of their biosafety and the low density value of about 4.51 g/cm3 [54]. CP Ti according to its purity, oxygen, carbon, and iron elements is usually classified into four grades (graded from I to IV); this chemical content determines the purity and grade of CP Ti [1,11]. Most of the used implant fixtures are manufactured from CP Ti grade IV and the abutments are made from Ti-6Al-4V alloy (grade V titanium alloy) [1,11]. The yield strength and fatigue properties of Ti-6Al-4V are higher than that of pure titanium, and the annealed Ti–6Al–4V has a yield strength in the range of 825–869 MPa and a plasticity of about 6–10%, to bear the stress magnitude from occlusal loading [55,56,57]. Furthermore, the wettability of titanium implant surfaces affects cell behavior in the initial osseointegration stage [7,17,58,59]. Considering the interaction of human body fluids, cells, and tissues with the implant surface, hydrophilic surfaces (water contact angle is ranging from 40° to 70°) are more suitable than hydrophobic surfaces [7,60]. The optimum parameters and characteristics regarding the contact angle are still controversial. Previous research [61] revealed that a hydrophilic surface optimization using Sand-blasted, Large-grit, and Acid-etching (SLA) led to a higher BIC percentage of 81.91% than a regular SLA process with 66.57% on CP Ti surfaces four weeks after implanting in miniature pigs.

1.2. Roughness and Morphology

The human skeleton exhibits a hierarchical structure of the macro-, micro-, and nano-scale levels, as seen in Figure 1 [62]. Bone consists of organic (type I and type IV collagen and fibrillin) and inorganic mineral (hydroxyapatite, HA) constituents. Considering the bone structure and density, its structure can be classified into two main types of bone: trabecular bone (cancellous bone) and cortical bone (compact bone). Cancellous bone is made of a porous network, and its porosity is in the range of 50–90%, depending on the specific location and age. Compact bone has a compact structure with a porosity in the range of 3–12% [14,63,64].
Numerous studies [17,65,66] indicate that the roughness and morphology features of the implant surface have considerable effects on the osseointegration rate and its fixation quality with bone. Surface roughness can be divided into three levels: macro-scale, micro-scale, and nano-scale [15]. The topographical roughness in macro-scale ranges from millimeters to tens of microns. Most of the macro-scale features are fabricated with screws, modifying the roughness to more than 10 μm [1,67]. The initial fixation and stability of implants can be increased by roughening the smooth surfaces. Furthermore, surfaces with high roughness values lead to a better interlocking reaction in the implant bone interface zone compared to smooth surfaces. Nevertheless, surfaces with high roughness also have some limitations such as the increase of peri-implantitis and ion leakage. The roughness value in the micro-scale condition ranges between 1 and 10 μm; this roughness range represents the best interlocking reaction between mineralized bone and implants [1,65,68]. A study reported [1] that the surface should be fabricated with hemispherical pits with approximately 1.5 μm depth and 4 μm diameter. The nano-scaled topography condition is in the range of less than one micrometer. There are various surface morphologies made using different techniques and the related adjusting process parameters, for instance, nano pit, nanotubular, nanowire, nanorod, and nanopore [44,69,70,71,72,73]. Accordingly, the Three-Dimensional Printing (3DP) and Laser Surface Texturing (LST) procedures improve the surface morphology at the macro-scale, while the grit-blasting and acid-etching procedures can produce surface features and morphologies at the micro-scale [74,75,76,77,78,79,80]. Plasma-spraying and anodization processes modify the morphology at nano-scale [81,82,83].

2. Results and Discussion

2.1. Macro-Scale Treatment

2.1.1. Three-Dimensional Printing

3DP is a well-established and versatile additive material technology that attracts the researchers’ attention due to its individuation in the fabrication of complex constructs [84]. Nowadays, in 3DP implant preparation, the major focus changes from mechanical strength optimization toward rapid bone regeneration and infection inhibition. 3DP technologies have the capability to fabricate porous implants with precise mechanical properties, favorable pore architectures, and even produce implants with patient-specific functional designs [8,83,85]. The 3DP manufactured implants from titanium and its alloys have been thoroughly studied and clinically used for decades, however, further research in this field is necessary to develop stabilized long-term properties. In this section, the factors influencing bone regeneration (for example, pore size, porosity, pore structure, and roughness) are discussed [86]. Meanwhile, the bone-formation ability of titanium implants by means of different manufacturing techniques will be explained, systematically [87,88]. It should be considered that the material structure design combined with biomimetic functionalization in order to enhance its long-term osseointegration capacity is necessary.
Over the past few decades, varieties of 3DP techniques have been thoroughly studied [8,89,90,91]. It is generally believed that 3DP techniques can be classified into main two categories with laser and electron beam input systems [92]. The representative technologies are selective laser melting (SLM) and electron beam melting (EBM). The processes of SLM is also known as laser beam melting (LBM), direct metal laser Sintering (DMLS), LaserCUSING, or laser metal fusion (LMF) [92], as shown in Figure 2 [93].
The implant surface roughness fabricated using SLM technology (arithmetical mean roughness (Ra): 5–20 µm)) is smoother than the EBM (Ra: 20–50 µm) counterpart, because of its smaller laser spot size and thinner layer thickness (30–50 vs. 50–70 µm), smaller powder size (average diameter 30–50 vs. 60–80 µm), and lower energy input [94,95]. Many reports have proved that titanium and its alloys prepared using SLM and EBM methods improved the osseointegration [96]. Nevertheless, a common standard for the optimum roughness has not been introduced yet. A study [97] has confirmed that the osseointegration of titanium implant surfaces can be enhanced by achieving the roughness range from 0.5 to 2.0 µm, thus, it is necessary to do further surface modifications in order to improve surface roughness.
The cytotoxicity of Ti-6Al-4V made using SLM and EBM approaches was evaluated with fibroblasts, and it was seen that there was not any significant difference between values in comparison to the negative control group [98]. The almost same results were observed [99] in the cell proliferation of Ti-6Al-4V treated using SLM and EBM with mesenchymal stromal cells (MSC). In another study [88], different basic structures (cubic, diagonal, pyramidal) for Ti-6Al-4V scaffolds are produced using SLM and EBM. Under static conditions, human primary osteoblasts were cultured on the samples. The cell activity and matrix production in both of the two groups increased (no significant difference). The collagen type 1 in Ti-6Al-4V SLM and EBM scaffold specimens with 700 µm pore size and 51% porosity revealed a remarkable increase during osteoblast differentiation [88].
There is a crucial evaluation criterion, BIC percentage; a higher BIC percentage means a greater bone ingrowth level. Experimental studies [79,88,100] reported that the pore size and porosity of SLM were 250–800 µm and 63%, and the pore size and porosity of EBM were 350–1400 µm and 49%, respectively. In the Ti-6Al-4V specimens, BIC was not observed, and there was also no sign of histological differences in the femoral condyle of goats after four weeks of implantation between the two groups. After implanting for 15 weeks, both of the two groups were intimately connected to the host bone, and the histomorphometry results showed that the BIC value of the EBM specimen group was higher than that of the SLM [101].
Structural characteristics of scaffold have vital effects on the mechanical properties and biological performance. Several studies [100,102,103] have revealed that the different architectures with different pore sizes (100–1000 μm), porosity (30–80%), and pore shapes promote the initial osseointegration period. However, there is a controversy about the optimal structure. Table 1 summarizes the research literature and lists the influencing factors like material, technology, scaffold, and biological performance.
In summary, 3DP technology is used to produce biomedical metal implants with complex shapes, which promise good prospects for their clinical application in the future. The standard regulatory guidelines for additive manufactured medical devices are a prerequisite to further medical implantation. Meanwhile, the reliability and repeatability of stable physicochemical properties, biological characteristics, security, and its specifications are necessary. Especially, surface modification in the 3DP implants is an indispensable concept in order to attain high osseointegration performances. Insufficient bone formation, vascularization, contiguous infection, and implant durability are still the main challenges. Lastly, the excessive production cost of the 3DP technique limits its further development and large-scale application.

2.1.2. Laser Surface Texturing

Nowadays, the bonding strength between bone and titanium implants can be increased using an LST technique [60,77,113]. These LST techniques have revealed a great potential to optimize the surface properties of biomedical implants through forming periodic textured patterns [80]. LST technology makes good use of thermal and photonic effects. The mechanism of LST is mainly based on ablation or vaporization. Accordingly, the effects of thermal conduction and fluid dynamics must be clarified during the process. There is no doubt that the processing efficiency and surface performance directly depend on the processing variables [77]. Thus, it must be pointed out that the topography and physicochemical and biological properties can be optimized according to different implant positioning. While some of the advantages of LST are obvious [114], for example, on the one hand, it is known as an environmentally friendly technology, on the other hand, it can modify the implant surfaces in a wide span range from macro-scale to nano-scale without any need for direct contact and it is free of any contaminations. Furthermore, the material surface treatment with this method is an automated procedure and can be used in complex shaped samples. In addition, the other advantage of the LST approach is its flexibility; it is also a non-contact procedure with high controllability and reproducibility. The process has a lower cost and higher efficiency compared to others, and it is suitable for automation and on-line monitoring. Hence, it can be utilized in the industrial applications instead of the ultrafast (femto/pico-second) laser [114]. However, some limitations and problems remain unsolved, such as the interaction between the laser beam with the material, making it difficult to be theoretically analyzed [77], and unfortunately, most of the previous studies focused on its empirical aspects.
To enhance the wear resistance of Ti-6Al-4V surfaces, Kümmel et al. [115] produced a linear channel (width: 30 µm, depth: 10 µm) with a semicircular cross-section by means of LST processing. The wear volume of the LST samples were 16 times lower than non-textured reference samples (1.6 × 107 µm3 VS. 0.1 × 107 µm3). Patel et al. [116] fabricated different densities, shapes, and directions pillars of textures on Ti-6Al-4V using an LST method and found that the contact angle value was reduced by increasing the size of the micro-pillars from 30 × 30 µm to 100 × 300 µm. Texture size and orientation not only optimize the physical and chemical properties but also improve the biological performance of the implants [117,118,119,120,121,122,123,124,125]. Chen and Mwenifumbo et al. [117,118] proved that cell orientation and cell adhesion are improved when the width of the grooves is 11 μm and the depth is 10 μm. Cell adhesion strength tests have indicated that the highest cell retention was seen on the linear textured surfaces with 20 μm intervals. In addition, a linear pattern texture presented a higher rate of cell retention than the waved pattern textures [119,120]. Furthermore, the interaction mechanism of the grooves and cell proliferation was demonstrated in detail. Chen et al. [121] displayed the enhanced cell adhesion in micro-grooved surfaces because of the interaction between the focal adhesions and extracellular matrix (ECM) proteins. Brånemark et al. [122] showed that the micro-scale and nano-scale topography or surface oxides formation using laser treatment increased the bone-implant biocompatibility. Soboyejo et al. [120] reported that the MC3T3 cells maintained the contact guidance and aligned along the microgrooves. It was further explained that reducing longitudinal groove intervals leads to an increment in the cell contact guidance [123,124,125]. A previous study [126] demonstrated that the density of MC3T3-E1 cells dropped in the textured surface, especially in dimple textured surfaces. XTT assay showed the results of the cell viability of MC3T3-E1 fibroblast cells after 24 h. The result showed no toxic effect and good cell viability in the LST group, as shown in Figure 3a. More cells were attached to ridges and corners than on dimples of the textured surfaces, as shown in Figure 3d–f [126]. The same situation was observed in MG63 cells [109], and another study [127] indicated that the average roughness on the dimple feature (Ra = 3.5 µm) was higher than that of the linear feature of the surface (Ra = 2.7 µm). It has been shown that LST technology evidently reduces the adhesion of Staphylococcus aureus (S. aureus) bacteria and biofilm formation hence decreases the risk of implant-associated infections [128]. Biofilms are multi-species communities of microbial cells located on the extracellular polymeric matrix, quorum sensing communication, and offer nutrients for bacteria. Furthermore, an extracellular polymeric matrix prevents the operation of antibiotics on bacteria actually, and it acts as a biological barrier since the biofilm receives a positive response from the immune system [129,130,131,132].
The advantage of LST technology mainly involves the capability of hierarchically controlling the surface texture (for instance by producing pits, grooves, pillars, ablation tracks, ripples, and columns), array pitch, depth, and other parameters to further change the surface roughness and improve the material’s abrasion resistance, contact angle, biological properties (such as cell adhesion and biocompatibility, reduction of S. aureus adhesion) and ultimately improving antimicrobial and rapid bone integration.

2.2. Micro-Scale Treatment

2.2.1. Grit-Blasting

After the processing of titanium samples to their final shape, usually, further surface treatment is required in order to roughen the surface, such as grit-blasting [1,11]. From long ago to the present day, grit-blasting has been an irreplaceable technology in surface treatment in which the hard ceramic particles are ejected by compressed air at a high velocity through a nozzle. The surface roughness mainly depends on the size of the ceramic particles, ranging from 110 to 250 μm. The ceramic particles should have some characterizations such as stability and biocompatibility, and they should also not affect the ingrowth of bone cells on titanium implants. Nevertheless, some entrapped abrasive particles are always found on the implant surfaces. These abrasive particles are usually of aluminum oxide (Al2O3), silicon oxide (SiO2), titanium oxide (TiO2), and calcium phosphate composition [133,134]. Al2O3 is often applied as the blasting material and it can be dissolved in acid. Blasting material particles are very hard to remove; even after ultrasonic cleaning, acid-etching, and sterilization they can be found on the sample surface. Evidently, these abrasive particles release in the peri-implant region and interfere with the osseointegration procedure. Furthermore, there is a possibility that these particles have a role in the reduction of corrosion resistance of implant surfaces in the body fluid environment [135].
TiO2 particles with an average size of 25 μm induce a medium roughness of about 1–2 μm. A study [136] revealed that the BIC value achieved by blasting the TiO2 particles remarkably is higher than the machined blasting surfaces. Meanwhile, current studies [68,137] have proved the BIC enhancement using TiO2 grit-blasting. After ten years of clinical implantation, studies [6,138] have shown a high clinical success rate of TiO2 grit-blasted titanium implant surfaces. Clinical studies [139,140] have reported higher marginal bone levels and survival rates after TiO2 grit-blasting than machined implants. A study [141] has revealed that when using grit-blasting with TiO2 or Al2O3 particles, the BIC does not show any significant differences. However, a TiO2 grit-blasted implant has increased mechanical fixation in comparison to smooth titanium surfaces. In addition, the torque force increases with the increment of surface roughness [142].
Calcium phosphate with its excellent compatibility, bioactivity, and biodegradability is also used as blasting media in titanium implant surfaces. Based on the crystalline type, calcium phosphates can be divided into α-tricalcium phosphate (α-TCP) and β-tricalcium phosphate (β-TCP). β-TCP and HA are identified as effective blasting materials, as these materials produce a clean and uniform texture on the titanium implant surface. The BIC value of calcium phosphate-treated surfaces is higher than that of machined surfaces [143,144]. Experimental studies have proved the BIC of a calcium phosphate-blasted surface was similar to other blasting materials during osseointegration.
A clinical study [145] reported the reliability of the secondary fixation by osseointegration in a straight standard grit-blasting titanium alloy used in non-anatomical implants. One hundred and ninety-eight Alloclassic™ total hip arthroplasties were performed in 179 patients, with a mean age of 66 years old (22–85), including 105 with proximal HA coating and 93 with the original grit-blast coating. The standard grit-blasted implant and HA coated standard grit-blasted implant are shown in Figure 4a,b [145]. The HA coating reduced the possible proximal fibrous encapsulation considering that the HA coating did not change the clinical results. Figure 4c [145] shows a straight Alloclassic™ THA (total hip arthroplasty) without HA coating implant in a 57-year-old female patient with a fracture of the femoral neck after removal of immediate postoperative control fixation hardware. The radiographic results after 23 years and 3 months of follow-up at the age of 80 years old and 5 months showed successful osseointegration, as shown in Figure 4d. These studies confirm that roughening the titanium implant surfaces increases bone-to-implant mechanical fixation but not its biological fixation.

2.2.2. Acid-Etching

Acid-etching is defined as a procedure of roughening titanium implant surfaces with strong acid solutions including hydrochloric acid (HCl), nitric acid (HNO3), sulfuric acid (H2SO4), hydrofluoric acid (HF), and other combined acid solutions. In some cases, the purpose of acid-etching processing is to remove the blasting residual particles remaining from the previous grit-blasting processes on the implant surfaces. Acid-etching usually fabricates the structure of the micro-pits with pit sizes in the range 0.5–2 μm [146,147]. The micro-pits and spike-like peaks lead to 1–2.7 μm average roughness on the material surfaces. Specific roughness depends on acid types, acid concentration, reaction temperature, and reaction time. A common acid-etching procedure is as follows: the implants are immersed in an acid solution for one hour with ultrasonic vibration at 60–100 °C. Then, the produced oxidized films on a titanium surface are dissolved in acid solution [61,148,149,150]. However, acid-etching has a negative effect on mechanical performance. The procedure might result in hydrogen embrittlement in the titanium implants, meanwhile cracks produced on the surface possibly weaken the fatigue resistance of the titanium [151]. In fact, some studies confirm the absorption of hydrogen in titanium and the release of some amount of it in the liquid body environment. In addition, hydrogen embrittlement is related to the formation of brittle hybrid phases. This phenomenon is also associated with the fracture mechanisms of titanium implants [151].
Surfaces treated using dual acid-etching (24% HF + HCl/H2SO4) can accelerate bone ingrowth, keeping its long-term success rate [152]. An experimental study [153] has reported that acid-etching surfaces have the capability to strengthen osseointegration, generally achieved by the attachment of fibrin and osteogenic cells around the implant surface. And woven bone with thin trabeculae covering the implant has been observed [154]. An experimental study [155] raised a presumption that dual acid-etching surfaces could attach to the fibrin scaffold and promote the adhesion of osteogenic cells. Studies [156,157] have demonstrated that dual acid-etching surfaces show higher BIC values and less bone absorption than machined surfaces. In recent decades, the acid-etching approach has been developed to enhance cell adhesion and bone formation. Another process involvess fluoride solution, which is used to modify the titanium surface, as titanium can react with fluoride ions, while forming soluble TiF4 species. This chemical treatment roughens the titanium surface and introduces TiF4 on the surface, which in turn promotes rapid bone ingrowth [158]. Another study [159] has reported that surfaces during HF treatment act in favor of osteoblastic differentiation when compared with the control group. In addition, fluoridated rough implants sustain higher strength and torque removal in comparison with control samples [160]. As is shown in Figure 5 [161], the morphology of an acid-etching surface of a commercially available implant is uniform with pits of approximately 3 μm in width [161,162]. The acid-etching method shows enormous potential in the improvement of bone-to-implant fixation due to an increase of bioactivity on the implant surface.

2.2.3. Sand-Blasted, Large-Grit, and Acid-Etched

In general, surface treatment by combining grit-blasting with acid-etching procedures is defined as SLA. Experimental studies [163,164,165,166,167] reported that SLA treated surfaces are beneficial, with increased biocompatibility in early bone formation stage and also in cell differentiation. The clinical success rate of SLA has achieved about 95% [168,169,170]. After SLA treatment, the topography of titanium implant surfaces provides positive effects on the activation of blood platelets and cell migration. Several experimental studies [9,169,171,172,173] demonstrated that the hydrophilicity of implant surfaces can further shorten the osseointegration process. In order to improve hydrophilicity, titanium implants are treated using SLA, and they are immersed in isotonic solution at low pH to produce a super-hydrophilic titanium surface. The approach is usually done by a commercial brand named SLActive [174]. The chemical stability can be fixed by the combination of acid-etching and conditioning it in an isotonic solution. The implant’s surface turns super-hydrophilic due to the application of chemical surface modification. By utilization of an SLA procedure in isotonic solutions, some spike-like nanofeatures can be produced on the surface of titanium [148,163,173]. Furthermore, it was seen [173] that the bonding strength increased between the nanostructured surface and bone tissue, measured by mechanical pulling out tests in rabbit tibia for eight weeks. Nanostructure features with further acceleration of the bone healing process are able to enhance protein adsorption, platelet aggregation, and macrophage adhesion [15,163,169,173,175,176,177]. An experimental study [178] revealed the up-regulation of pro-osteogenic cell signaling pathways and osteocalcin on ultra-hydrophilic titanium surfaces. Compared with acid-etching surfaces, the super-hydrophilic surface can increase BIC in 2–4 weeks [179,180,181,182,183,184]. The average BIC on SLA surfaces showed to be in the range of 67–81% for 6 months. A 10-year follow-up study [185] of marginal bone loss demonstrated that the clinical success rate reached 95.1% for acid-etching implant surfaces. Other studies [10,186] of immediate provisional restorations on implant surfaces have reported a clinical success rate of about 100% on super-hydrophilic implant surfaces with positive aesthetic outcomes. Zhang et al. [167] demonstrated the osteogenic performance of SLA and 3DA (3DP and acid-etching) implants in the femoral condyle of SD rats for 3 and 6 weeks, as is shown in Figure 6 [167]. The BIC of an SLA implant as higher than that of a 3DA implant (in Figure 6a,b) [167]), thus, SLA processing still cannot be replaced. Micro-scale and nano-scale modification have revealed a positive effect on osteogenic cell growth because they produce a hierarchical structure by imitating the skeleton.

2.3. Nano-Scale Treatment

2.3.1. Plasma-Spraying

For several decades, plasma-spraying, as a safe and reliable nano-scale coating technology, has been used for roughening implant surfaces. Plasma-spraying equipment consists of a DC electrical power source, gas flow control, a water-cooling system, and a powder feeder. Plasma spraying technology is a physical method, which involves spraying melted coating material onto Ti substrate surfaces using a direct current arc plasma gun, producing a 30-μm thick coating. Actually, the optimal thickness of the film is approximately 50 μm [67] and the average roughness of the coating is approximately 7 μm, and it also increases the implant surface area [67].
A study [187] has reported that a three-dimensional topography formation increased the mechanical interlock and tensile strength between bone and implant surfaces. The bone-to-implant interface was produced faster after plasma-spraying treatment compared to that of smooth surfaces. Nevertheless, titanium particles are observed in the peri-implant region [188]. The observed titanium wear particles are from the bone-to-implant interface, scattering among the organs in the minipigs implant experiment [188]. The released metallic ions are the product of dissolution or wear processes. In this regard, the local and systemic carcinogenic potential effects may attract people’s attention and leads to some limitations in its clinical application [189]. No clinical differences between SLA and plasma-spraying methods in the interface of titanium implants were reported in a study by Loughlin [190]. Another study [191] showed that the BIC on the plasma-sprayed surface is lower than on the plasma-sprayed HA coating surface.
A large number of studies [81,192,193,194,195,196] have reported composite materials coatings modification using plasma-spraying treatment on titanium implant surfaces. Li et al. [192] fabricated nano-TiO2/Ag and nano-TiO2 coatings using a plasma-spraying technique on titanium substrates to improve the bioactive and antibacterial properties. From water contact angle and MG-63 cell adhesion and proliferation tests, there were no significant differences between nano-TiO2/Ag and nano-TiO2 samples. However, in the samples containing Ag particles, the percent reduction of Escherichia coli reached approximately 100% after 24 h, and the loaded Ag particles did not show obvious osteo-toxicity. Ke et al. [194] produced the HA layer using laser engineered net shaping (LENSTM) on Ti-6Al-4V substrates, and then prepared HA/MgO/Ag2O coating using plasma-spraying in order to enhance the strength of the adhesive bond between the coating and substrates, as shown in Figure 7 [194]. Compared with just plasma-spraying coating condition, LENSTM and plasma-spraying procedures increased the bond strength from 26 ± 2 MPa to 39 ± 4 MPa. Additionally, the Ag ions release amount reduced to 70% due to crystallization enhancement by the LENSTM HA layer. In vitro human osteoblast cell culture assays indicated that Ag2O (2 wt%) was a quite safe coating since an antibacterial characteristic was observed against E. coli and S. aureus in Ag2O coatings. Another investigation [195] has reported improved wettability after plasma-spraying treatment. The results revealed that unheated treated HA-ZrO2 and HA-TiO2 coating modified by plasma-spraying showed better hydrophilicity than the heat-treated condition, and the water contact angle was 25° and 35°, respectively. It is worth mentioning that both ZrO2 and heat treatment can enhance the hardness of material surfaces [196]. In a Sprague-Dawley rats model experiment for five weeks, the rate of bone mineralization of plasma-spraying ZnO(0.25 wt%)/SiO2 (0.5 wt%)/Ag2O(2.0 wt%)-HA composite coating was 32%, while it was about 11% in the plasma-spraying HA coating group [197]. Utilization of TiO2, Ag2O, ZrO2, ZnO, and SiO2 in a suitable content is beneficial for the antibacterial property, hardness, osteo-conduction, and early bone formation [193].
In fact, the corresponding standards about the plasma-spraying treatment on titanium implants in clinical applications are briefly reported in this review paper. However, this technology still has enormous potential to develop in the future.

2.3.2. Anodization

Anodization technology is a mature technology to change the roughness and topographic features on the surface of titanium with many influencing variables, for instance, oxidation duration, oxidation voltage, electrolyte solution type, electrolyte solution concentration, and the subsequent heat treatment process. Nanopores and nanotubes can be induced by constant potential anodization in different acid solutions (e.g., H2SO4, HF, H3PO4, HNO3) for various time spans [11,198]. A uniform oxide layer forms on the titanium surface with a thickness of about a few hundred nanometers up to a few microns [199]. The anodic oxide film is formed by the charging of the double electric layer at the metal-electrolyte interface. The mechanism is dissolution of oxide film assisted by the electric field and it is enhanced by temperature, involving the formation of a soluble salt containing the metal cation and an anion in the electrolytic bath. After establishing a stable potential, the current gradually decreases due to either a decrease in Ti3+ in the membrane layer or an increase in the integrity of the membrane layer, which can lead to a significant increase in resistance, resulting in a reduced current [200]. Compared with machined surfaces, anodized surfaces enhanced the bone response in biomechanical and histomorphometric experiments [201]. The anodized preparation process and TiO2 nanotubes array are shown in Figure 8a,b. In Figure 8c, CaO is observed on the surface of NT-RP-Ca/P. The potentiodynamic polarization curves observed in Figure 8d show that samples containing nanotube (NT and NT-RP-Ca) exhibited a passive region extending over a wide potential range when compared to Ti surfaces. Bone-like structured TiO2 nanotubes displayed superior corrosion resistance ability. In addition, bone-like structured TiO2 nanotubes enriched with calcium and phosphorous have enhanced osteoblastic cell functions with MG-63 cells, as is shown in Figure 8e [198]. In another study [202], the clinical success rate of anodized implants are reported to be higher than that of machined titanium surfaces. There are two mechanisms to explain the osseointegration: mechanical interlocking and biochemical bonding observed between implant material and bone [66,203]. Among the many metal and salt ions (Ti, Mg, P, Ca, S) [204,205], the incorporation of Mg ions is the best way to remove the torque value [66].
The anodized studies in references [198,206] possess nano-scale surfaces, enabling them to load and deliver multifunctional molecules and growth factors to accelerate early bone integration. The wall thickness, diameter, and length of nanotubes directly depend on the anodization parameters such as oxide temperature, voltage, time, and electrolyte concentration [199]. Nanotubes increase the contact surface area resulting in an increase in wettability and adsorption of proteins and ions [198,207,208,209]. Loading antibacterial ions on nanotubes can prevent biofilm formation and reduce the bacteria in the peri-implant region to avoid early failure of the implant [210,211,212]. The length range of anodized nanotube array lies between 7 and 10 μm. The inner diameter range and the external diameter range are 20–100 nm and 30–110 nm, respectively [198,206]. The nanotube spacing is suitable for the transformation of waste and nutrients [213]. The TiO2 nanotube size can be adjusted by changing the anodization parameters in order to achieve a similar size as the skeleton. The diameter of cortical bone is reported to be in the range of 10–500 μm, while the diameter of the cancellous bone is 0.2–1 mm [14,199,214]. In addition, nanotube arrays try to simulate the size and arrangement of collagen fibrils in the bone tissue [215]. Several experimental studies [216,217] indicated that the length of TiO2 nanotubes has an influence on biocompatibility, while their diameter has a critical effect on cell adhesion and proliferation. The best osteoconductivity was reported in for 70 nm diameter nanotubes, meanwhile, 80 nm diameter nanotubes also showed improved proliferation and differentiation behavior [199,218,219]. Additionally, the extra annealing (600 °C 3 h) in the heat treatment stage seems to be beneficial for the best wettability behavior with a 62° water contact angle for improved cellular response [220]. There are three crystalline phases of TiO2 including anatase, rutile, and brookite. Anatase forms with annealing at 400–600 °C for 2–3 h [221]. Rutile begins to form with annealing at more than 700 °C for 2–3 h [222]. Furthermore, the anatase crystallization of TiO2 nanotubes enhances the hydrophilicity of the annealed surfaces resulting in a rise in protein adsorption [223].
In brief, nano-scale feature formation on titanium can improve protein adsorption, osteoblastic cell adhesion and proliferation, and the healing rate of the implant periphery zone. The anodization procedure produces a uniform and regular topography; in particular, TiO2 nanotube arrays are also developed as a drug loading system to deliver corresponding drugs. The advantage of this system is that the delivered multifunctional drugs can be released in the predetermined time span and then can be released into the interface of titanium implants [224]. TiO2 nanotubes are beneficial for utilization in drug delivery systems. The tube length, diameter, and phase are adjustable according to the desired demands. In view of common electrochemical approaches to fabricate micro/nanopores and nanotubes on implant surfaces in electrolyte solutions with a settled voltage and time, the production of standard implants seems to be feasible from an industrial perspective. Considering the present studies about nanotube fabrication on titanium implants, the special design and identification of the modern nanotube-modified implants depend on their clinical benefits, the demands of patients, and the interests of the producers.

3. Conclusions

There are a large number of surface treatment approaches commercially available for producing titanium implant surfaces. Nowadays, surface modification techniques (for instance, 3DP, grit-blasting, acid-etching, plasma-spraying, and anodization) have proven clinical efficacy. Reaching to a favorable surface morphology after surface modification plays a vital role in enhancing early osseointegration. In particular, multi-scale combined topography (such as macro-scale, micro-scale, and nano-scale) can shorten the phase of bone ingrowth. Blood platelet activation, protein adsorption, three-dimensional fibrin clot cross-linking, osteogenic cell migration, collagen deposition, and bone matrix formation are the main factors affecting the osseointegration process. Wettability, roughness, and chemical composition are the bridges connecting the physicochemical properties and biological properties of titanium alloy surfaces. It’s worth noting that there are still no strict requirements and qualified standards for implant surface morphology design. In addition, a large amount of pre-clinical and clinical experiments need to be done to further ensure the security and reliability of implants using new technologies. In addition, the high cost is another limitation that creates a lot of difficulties in the clinical validation stage of implant design. The future modern implants should satisfy the following characteristics: biomimetic and standardized properties, slow rate of material release into the body environment, and low cost. Multi-scale surface treated implants show considerable potential in order to design modern implant materials with enhanced properties.

Author Contributions

L.W. and S.L.: resources. R.L.-W.M. and Y.Z.: data curation. Q.W.: writing—original draft preparation. Q.W., P.Z. and S.A.: writing—review, editing, and supervision. S.L. and L.W.: project funding acquisition. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Science Foundation under Grant No. 31971246, 51831011, 51874225, 51671152, Medical Engineering Cross Fund Project of Shanghai Jiao Tong University YG 2019QN46. The Youth Innovation Team of Shaanxi Universities (2019–73) and The Industrialization Project of Shaanxi Education Department (18JC019).

Acknowledgments

The authors sincerely thank Dongbei Zhang and Junyin Wu from Shanghai Jiao Tong University for data analysis of this paper. All authors have read and agreed to the published version of the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Guéhennec, L.L.; Soueidan, A.; Layrolle, P.; Inserm, Y.A. Surface treatments of titanium dental implants for rapid osseointegration. Dent. Mater. 2006, 3, 844–854. [Google Scholar] [CrossRef] [PubMed]
  2. Xiao, L.; Wu, S.; Liu, B.; Yang, H.; Yang, L. Advances in metallic biomaterials with both osteogenic and anti-infection properties. ACTA Metall. Sin. 2017, 53, 1284–1302. [Google Scholar]
  3. Spriano, S.; Yamaguchi, S.; Baino, F.; Ferraris, S. A critical review of multifunctional titanium surfaces: New frontiers for improving osseointegration and host response, avoiding bacteria contamination. Acta Biomater. 2018, 79, 1–22. [Google Scholar] [CrossRef]
  4. Brånemark, P.-I.; Breine, U.; Adell, R.; Hansson, B.O.; Lindström, J.; Ohlsson, Å. Intra-osseous anchorage of dental prostheses: I. Experimental studies. Scand. J. Plast. Reconstr. Surg. 1969, 3, 81–100. [Google Scholar] [CrossRef]
  5. Chrcanovic, B.R.; Kisch, J.; Albrektsson, T.; Wennerberg, A. A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years. Clin. Implant Dent. Relat. Res. 2018, 20, 199–207. [Google Scholar] [CrossRef]
  6. Rasmusson, L.; Roos, J.; Bystedt, H. A 10-year follow-up study of titanium dioxide–blasted implants. Clin. Implant Dent. Relat. Res. 2005, 7, 36–42. [Google Scholar] [CrossRef]
  7. Gittens, R.A.; Scheideler, L.; Rupp, F.; Hyzy, S.L.; Geis-gerstorfer, J.; Schwartz, Z.; Boyan, B.D. A review on the wettability of dental implant surfaces II: Biological and clinical aspects. Acta Biomater. 2014, 10, 2907–2918. [Google Scholar] [CrossRef] [Green Version]
  8. Bose, S.; Traxel, K.D.; Vu, A.A.; Bandyopadhyay, A. Clinical significance of three-dimensional printed biomaterials and biomedical devices. Mater. Res. Soc. 2019, 44, 494–504. [Google Scholar] [CrossRef] [Green Version]
  9. Donos, N.; Horvath, A.; Mezzomo, L.A.; Dedi, D.; Calciolari, E.; Mardas, N. The role of immediate provisional restorations on implants with a hydrophilic surface: A randomised, single-blind controlled clinical trial. Clin. Oral Implants Res. 2018, 29, 55–66. [Google Scholar] [CrossRef] [Green Version]
  10. Nelson, K.; Stricker, A.; Raguse, J.; Nahles, S. Rehabilitation of irradiated patients with chemically modified and conventional SLA implants: A clinical clarification. Oral Rehabil. 2016, 43, 871–872. [Google Scholar] [CrossRef] [PubMed]
  11. Souza, J.C.M.; Sordi, M.B.; Kanazawa, M.; Ravindran, S.; Henriques, B.; Silva, F.S.; Aparicio, C.; Cooper, L.F. Nano-scale modification of titanium implant surfaces to enhance osseointegration. Acta Biomater. 2019, 94, 112–131. [Google Scholar] [CrossRef] [PubMed]
  12. Ye, L. Current dental implant design and its clinical importance. West China J. Stomatol. 2017, 35, 18–28. [Google Scholar]
  13. Albrektsson, T.; Brånemark, P.I.; Hansson, H.A.; Lindstrom, J. Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Am. J. Otol. 1981, 2, 155–170. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Coelho, P.G.; Jimbo, R.; Tovar, N.; Bonfante, E.A. Osseointegration: Hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales. Dent. Mater. 2015, 31, 37–52. [Google Scholar] [CrossRef]
  15. Mendonça, G.; Mendonça, D.B.S.; Araga, F.J.L. Advancing dental implant surface technology—From micron- to nanotopography. Biomaterials 2008, 29, 3822–3835. [Google Scholar] [CrossRef]
  16. Mendonça, G.; Mendonça, D.B.S.; Simões, L.G.P.; Araújo, A.L.; Leite, E.R.; Duarte, W.R.; Aragão, F.J.L.; Cooper, L. The effects of implant surface nanoscale features on osteoblast- specific gene expression. Biomaterials 2009, 30, 4053–4062. [Google Scholar] [CrossRef]
  17. Nelson, C.; Oshida, Y.; Henrique, J.; Lima, C.; Alberto, C. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque. J. Mech. Behav. Biomed. Mater. 2008, 1, 234–242. [Google Scholar]
  18. Tovani, C.B.; Faria, A.N.; Ciancaglini, P.; Ramos, A.P. Collagen-supported CaCO3 cylindrical particles enhance Ti bioactivity. Surf. Coat. Technol. 2019, 358, 858–864. [Google Scholar] [CrossRef]
  19. Schünemann, F.H.; Galárraga-vinueza, M.E.; Magini, R.; Fredel, M.; Silva, F.; Souza, J.C.M.; Zhang, Y.; Henriques, B. Zirconia surface modifications for implant dentistry. Mater. Sci. Eng. C 2019, 98, 1294–1305. [Google Scholar] [CrossRef]
  20. Kaur, M.; Singh, K. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. Mater. Sci. Eng. C 2019, 102, 844–862. [Google Scholar] [CrossRef]
  21. Hosoki, M.; Nishigawa, K.; Miyamoto, Y.; Ohe, G.; Matsuka, Y. Allergic contact dermatitis caused by titanium screws and dental implants. J. Prosthodont. Res. 2016, 60, 213–219. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  22. Sivaraman, K.; Chopra, A.; Narayan, A.I.; Balakrishnan, D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J. Prosthodont. Res. 2018, 62, 121–133. [Google Scholar] [CrossRef] [PubMed]
  23. Wang, L.; Lu, W.; Qin, J.; Zhang, F.; Zhang, D. Tensile properties of in situ synthesized (TiB + La2O3)/β-Ti composite. Mater. Sci. Eng. C 2009, 29, 1897–1900. [Google Scholar] [CrossRef]
  24. Ding, Z.; Xie, L.; Zhang, L.; Wang, L.; Lu, W. Effects of friction stir processing on the phase transformation and microstructure of TiO2-compounded Ti-6Al-4V alloy. Metall. Mater. Trans. A 2016, 47, 5675–5679. [Google Scholar] [CrossRef]
  25. Arabnejad, S.; Johnston, R.B.; Ann, J.; Singh, B.; Tanzer, M.; Pasini, D. High-strength porous biomaterials for bone replacement: A strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints. Acta Biomater. 2016, 30, 345–356. [Google Scholar] [CrossRef] [Green Version]
  26. Wang, L.; Wang, C.; Zhang, L.C.; Chen, L.; Lu, W.; Zhang, D. Phase transformation and deformation behavior of NiTi-Nb eutectic joined NiTi wires. Sci. Rep. 2016, 6, 23905. [Google Scholar] [CrossRef]
  27. Hafeez, N.; Liu, J.; Wang, L.; Wei, D.; Tang, Y.; Lu, W.; Zhang, L.C. Superelastic response of low-modulus porous beta-type Ti-35Nb-2Ta-3Zr alloy fabricated by laser powder bed fusion. Addit. Manuf. 2020, 34, 101264. [Google Scholar] [CrossRef]
  28. Wang, L.; Xie, L.; Zhang, L.C.; Chen, L.; Ding, Z.; Lv, Y.; Zhang, W.; Lu, W.; Zhang, D. Microstructure evolution and superelasticity of layer-like NiTiNb porous metal prepared by eutectic reaction. Acta Mater. 2018, 143, 214–226. [Google Scholar] [CrossRef]
  29. Liu, S.; Liu, J.; Wang, L.; Ma, R.L.W.; Zhong, Y.; Lu, W.; Zhang, L.C. Superelastic behavior of in-situ eutectic-reaction manufactured high strength 3D porous NiTi-Nb scaffold. Scr. Mater. 2020, 181, 121–126. [Google Scholar] [CrossRef]
  30. Wang, L.; Lu, W.; Qin, J.; Zhang, F.; Zhang, D. Influence of cold deformation on martensite transformation and mechanical properties of Ti-Nb-Ta-Zr alloy. J. Alloys Compd. 2009, 469, 512–518. [Google Scholar] [CrossRef]
  31. Wang, L.; Lu, W.; Qin, J.; Zhang, F.; Zhang, D. Effect of precipitation phase on microstructure and superelasticity of cold-rolled beta titanium alloy during heat treatment. Mater. Des. 2009, 30, 3873–3878. [Google Scholar] [CrossRef]
  32. Wang, L.; Lu, W.; Qin, J.; Zhang, F.; Zhang, D. The characterization of shape memory effect for low elastic modulus biomedical β-type titanium alloy. Mater. Charact. 2010, 61, 535–541. [Google Scholar] [CrossRef]
  33. Wang, L.; Lu, W.; Qin, J.; Zhang, F.; Zhang, D. Microstructure and superelasticity of in situ synthesized (TiB + La2O3)/Ti-alloy composites with different mass fraction of LaB6. Mater. Sci. Eng. A 2010, 527, 1058–1062. [Google Scholar] [CrossRef]
  34. Guo, X.; Wang, L.; Wang, M.; Qin, J.; Zhang, D.; Lu, W. Effects of degree of deformation on the microstructure, mechanical properties and texture of hybrid-reinforced titanium matrix composites. Acta Mater. 2012, 60, 2656–2667. [Google Scholar] [CrossRef]
  35. Guo, Y.; Chen, D.; Lu, W.; Jia, Y.; Wang, L.; Zhang, X. Corrosion resistance and in vitro response of a novel Ti35Nb2Ta3Zr alloy with a low Young’s modulus. Biomed. Mater. 2013, 8, 055004. [Google Scholar] [CrossRef]
  36. Guo, Y.; Chen, D.; Cheng, M.; Lu, W.; Wang, L.; Zhang, X. The bone tissue compatibility of a new Ti35Nb2Ta3Zr alloy with a low Young’s modulus. Int. J. Mol. Med. 2013, 31, 689–697. [Google Scholar] [CrossRef] [Green Version]
  37. Wang, L.; Wang, C.; Lu, W.; Zhang, D. Superelasticity of NiTi-Nb metallurgical bonding via nanoindentation observation. Mater. Lett. 2015, 161, 255–258. [Google Scholar] [CrossRef] [Green Version]
  38. Wang, L.; Xie, L.; Lv, Y.; Zhang, L.-C.; Chen, L.; Meng, Q.; Qu, J.; Zhang, D.; Lu, W. Microstructure evolution and superelastic behavior in Ti-35Nb-2Ta-3Zr alloy processed by friction stir processing. Acta Mater. 2017, 131, 499–510. [Google Scholar] [CrossRef] [Green Version]
  39. Gu, H.; Ding, Z.; Yang, Z.; Yu, W.; Zhang, W.; Lu, W.; Zhang, L.; Wang, K.; Wang, L.; Fu, Y. Microstructure evolution and electrochemical properties of TiO2/Ti-35Nb-2Ta-3Zr micro/nano-composites fabricated by friction stir processing. Mater. Des. 2019, 169, 107680. [Google Scholar] [CrossRef]
  40. Pierre, C.; Bertrand, G.; Rey, C.; Benhamou, O. Calcium phosphate coatings elaborated by the soaking process on titanium dental implants: Surface preparation, processing and physical-chemical characterization. Dent. Mater. 2018, 35, e25–e35. [Google Scholar] [CrossRef] [Green Version]
  41. Yoo, D.; Tovar, N.; Jimbo, R.; Marin, C.; Anchieta, R.B.; Machado, L.S.; Montclare, J.; Guastaldi, F.P.S.; Janal, M.N.; Coelho, P.G. Increased osseointegration effect of bone morphogenetic protein 2 on dental implants: An in vivo study. J. Biomed. Mater. Res. Part A 2013, 102, 1921–1927. [Google Scholar] [CrossRef] [PubMed]
  42. Zhu, C.; Lv, Y.; Qian, C.; Ding, Z.; Jiao, T.; Gu, X.; Lu, E.; Wang, L.; Zhang, F. Microstructures, mechanical, and biological properties of a novel Ti-6V-4V/zinc surface nanocomposite prepared by friction stir processing. Int. J. Nanomed. 2018, 13, 1881–1898. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  43. Lv, Y.; Ding, Z.; Xue, J.; Sha, G.; Lu, E.; Wang, L.; Lu, W.; Su, C.; Zhang, L.-C. Deformation mechanisms in surface nano-crystallization of low elastic modulus Ti6Al4V/Zn composite during severe plastic deformation. Scr. Mater. 2018, 157, 142–147. [Google Scholar] [CrossRef]
  44. Rangel, A.L.R.; Falentin-daudré, C.; Natália, B.; Pimentel, S.; Eduardo, C.; Migonney, V.; Alves, A.P.R. Nanostructured titanium alloy surfaces for enhanced osteoblast response: A combination of morphology and chemistry. Surf. Coat. Technol. 2020, 383, 125226. [Google Scholar] [CrossRef]
  45. Tian, L.; Tang, N.; Ngai, T.; Wu, C.; Ruan, Y.; Huang, L.; Qin, L. Hybrid fracture fixation systems developed for orthopaedic applications: A general review. J. Orthop. Transl. 2019, 16, 1–13. [Google Scholar] [CrossRef]
  46. Liu, P.; Hao, Y.; Zhao, Y.; Yuan, Z.; Ding, Y.; Cai, K. Surface modification of titanium substrates for enhanced osteogenetic and antibacterial properties. Colloids Surf. B Biointerfaces 2017, 160, 110–116. [Google Scholar] [CrossRef]
  47. Zhu, C.; Lv, Y.; Qian, C.; Qian, H.; Jiao, T.; Wang, L. Proliferation and osteogenic differentiation of rat BMSCs on a novel Ti/SiC metal matrix nanocomposite modified by friction stir processing. Sci. Rep. 2016, 6, 38875. [Google Scholar] [CrossRef] [Green Version]
  48. Nyoung, D.; Ko, W.; Rae, H.; Jin, S.; Lee, D.; Ho, S.; Haeng, J.; Woo, Y.; Grace, L.; Lee, D.; et al. Titanium dental implants surface-immobilized with gold nanoparticles as osteoinductive agents for rapid osseointegration. J. Colloid Interface Sci. 2016, 469, 129–137. [Google Scholar]
  49. Isola, G.; Alibrandi, A.; Currò, M.; Matarese, M.; Ricca, S.; Matarese, G.; Ientile, R.; Kocher, T. Evaluation of salivary and serum ADMA levels in patients with periodontal and cardiovascular disease as subclinical marker of cardiovascular risk. J. Periodontol. 2020, 1–9. [Google Scholar] [CrossRef]
  50. Isola, G.; Polizzi, A.; Alibrandi, A.; Indelicato, F.; Ferlito, S. Analysis of endothelin-1 concentrations in individuals with periodontitis. Sci. Rep. 2020, 10, 1–8. [Google Scholar] [CrossRef]
  51. Isola, G.; Alibrandi, A.; Rapisarda, E.; Matarese, G.; Williams, R.C.; Leonardi, R. Association of vitamin D in patients with periodontitis: A cross-sectional study. J. Periodontal Res. 2020, 1–11. [Google Scholar] [CrossRef] [PubMed]
  52. Khoo, L.K.; Sakdajeyont, W.; Khanijou, M.; Seriwatanachai, D. Titanium fixture implants treated by laser in dentistry: Review article. J. Oral Maxillofac. Surg. Med. Pathol. 2019, 31, 381–385. [Google Scholar] [CrossRef]
  53. Dai, N.; Zhang, L.-C.; Zhang, J.; Chen, Q.; Wu, M. Corrosion behaviour of selective laser melted Ti-6Al-4V alloy in NaCl solution. Corros. Sci. 2015, 102, 484–489. [Google Scholar] [CrossRef]
  54. Liu, X.; Chu, P.K.; Ding, C. Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mater. Sci. Eng. R 2005, 47, 49–121. [Google Scholar] [CrossRef] [Green Version]
  55. Zhang, L.-C.; Chen, L.-Y.; Wang, L. Surface modification of titanium and titanium alloys: Technologies, developments, and future interests. Adv. Eng. Mater. 2020. [Google Scholar] [CrossRef]
  56. Niinomi, M. Mechanical properties of biomedical titanium alloys. Mater. Sci. Eng. A 1998, 243, 231–236. [Google Scholar] [CrossRef]
  57. Xie, L.; Wen, Y.; Zhan, K.; Wang, L.; Jiang, C.; Ji, V. Characterization on surface mechanical properties of Ti-6Al-4V after shot peening. J. Alloys Compd. 2016, 666, 6. [Google Scholar] [CrossRef]
  58. Gittens, R.A.; Olivares-navarrete, R.; Cheng, A.; Anderson, D.M.; Mclachlan, T.; Stephan, I.; Geis-gerstorfer, J.; Sandhage, K.H.; Fedorov, A.G.; Rupp, F.; et al. The roles of titanium surface micro/nanotopography and wettability on the differential response of human osteoblast lineage cells. Acta Biomater. 2013, 9, 6268–6277. [Google Scholar] [CrossRef] [Green Version]
  59. Zhang, L.; Wu, L.; Fu, Y.; Wang, L.; Lu, W. Electrochemical and in vitro behavior of the nanosized composites of Ti-6Al-4V and TiO2 fabricated by friction stir process. Appl. Surf. Sci. 2017, 423, 331–339. [Google Scholar] [CrossRef]
  60. Hao, L.; Yang, H.; Du, C.; Fu, X.; Zhao, N.; Xu, S.; Cui, F.; Mao, C.; Wang, Y. Directing the fate of human and mouse mesenchymal stem cells by hydroxyl-methyl mixed self-assembled monolayers with varying wettability. Mater. Chem. B 2014, 2, 4794–4801. [Google Scholar] [CrossRef] [Green Version]
  61. Buser, D.; Broggini, N.; Wieland, M.; Schenk, R.K.; Denzer, A.J.; Cochran, D.L. Enhanced bone apposition to a chemically modified sla titanium surface. J. Dent. Res 2004, 83, 529–533. [Google Scholar] [CrossRef] [PubMed]
  62. Wang, X.; Xu, S.; Zhou, S.; Xu, W.; Leary, M.; Choong, P.; Qian, M.; Brandt, M.; Min, Y. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: A review. Biomaterials 2016, 83, 127–141. [Google Scholar] [CrossRef] [PubMed]
  63. Yin, C.; Zhang, Y.; Cai, Q.; Li, B.; Yang, H.; Wang, H.; Qi, H.; Zhou, Y.; Meng, W. Effects of the micro-nano surface topography of titanium alloy on the biological responses of osteoblast. J. Biomed. Mater. Res. 2017, 105, 757–769. [Google Scholar] [CrossRef] [PubMed]
  64. Rho, J.; Kuhn-Spearing, L.; Zioupos, P. Mechanical properties and the hierarchical structure of bone. Med. Eng. Phys. 1998, 20, 92–102. [Google Scholar] [CrossRef]
  65. Gittens, R.A.; Mclachlan, T.; Olivares-navarrete, R.; Cai, Y.; Berner, S.; Tannenbaum, R.; Schwartz, Z.; Sandhage, K.H.; Boyan, B.D. The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation. Biomaterials 2011, 32, 3395–3403. [Google Scholar] [CrossRef] [Green Version]
  66. Sul, Y.T.; Johansson, C.; Wennerberg, A.; Cho, L.R.; Albrektsson, T. Optimum surface properties of oxidized implants for reinforcement of osseointegration: Surface chemistry, oxide thickness, porosity, roughness, and crystal structure. Inter. J. Oral Maxillofac. Implants 2005, 20, 349–359. [Google Scholar]
  67. Buser, D.; Schenk, R.K.; Steinemann, S.; Fiorellin, J.P.; Fox, C.H.; Stich, H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. Biomed. Mater. Res. 1991, 25, 889–902. [Google Scholar] [CrossRef]
  68. Gotfredsen, K.; Wennerberg, A.; Johansson, C.; Teil, L.; Hjsrting-hansen, E. Anchorage of TiO2-blasted, HA-coated, and machined implants: An experimental study with rabbits. Biomed. Mater. Res. 1995, 29, 1223–1231. [Google Scholar] [CrossRef]
  69. Dobbenga, S.; Fratila-apachitei, L.E.; Zadpoor, A.A. Nanopattern-induced osteogenic differentiation of stem cells—A systematic review. Acta Biomater. 2016, 46, 3–14. [Google Scholar] [CrossRef]
  70. Lv, L.; Liu, Y.; Zhang, P.; Zhang, X.; Liu, J.; Chen, T.; Su, P.; Li, H.; Zhou, Y. The nanoscale geometry of TiO2 nanotubes in fluences the osteogenic differentiation of human adipose-derived stem cells by modulating H3K4 trimethylation. Biomaterials 2015, 39, 193–205. [Google Scholar] [CrossRef]
  71. Minagar, S.; Li, Y.; Berndt, C.C.; Wen, C. The influence of titania-zirconia-zirconium titanate nanotube characteristics on osteoblast cell adhesion. Acta Biomater. 2015, 12, 281–289. [Google Scholar] [CrossRef] [PubMed]
  72. Fan, R.; Wan, J. Electrode distance regulates the anodic growth of titanium dioxide (TiO2) nanotubes. Nanotechnology 2017, 28, 25LT01. [Google Scholar] [CrossRef] [PubMed]
  73. Weszl, M.; László, K.; Kientzl, I.; Nagy, P.; Pammer, D.; Pelyhe, L.; Vrana, N.E.; Scharnweber, D.; Wolf-brandstetter, C.; Árpád, J.F.; et al. Investigation of the mechanical and chemical characteristics of nanotubular and nano-pitted anodic fi lms on grade 2 titanium dental implant materials. Mater. Sci. Eng. C 2017, 78, 69–78. [Google Scholar] [CrossRef] [Green Version]
  74. Elsayed, M.; Essa, K. Optimization of SLM process parameters for Ti6Al4V medical implants. Rapid Prototyp. J. 2019, 3, 433–447. [Google Scholar] [CrossRef] [Green Version]
  75. Sadeghi, M.; Kharaziha, M.; Salimijazi, H.R.; Tabesh, E. Role of micro-dimple array geometry on the biological and tribological performance of Ti6Al4V for biomedical applications. Surf. Coat. Technol. 2019, 362, 282–292. [Google Scholar] [CrossRef]
  76. Lukaszewska-kuska, M.; Leda, B.; Gajdus, P.; Hedzelek, W. Evaluation of modified titanium surfaces physical and chemical characteristics. Nucl. Inst. Methods Phys. Res. B 2017, 411, 94–99. [Google Scholar] [CrossRef]
  77. Pou, P.; Riveiro, A.; Val, J.; Comesaña, R.; Penide, J.; Arias-González, F.; Sotoa, R.; Lusquiños, F.; Pou, J. Laser surface texturing of Titanium for bioengineering applications. Procedia Manuf. 2017, 13, 694–701. [Google Scholar] [CrossRef]
  78. Chern, A.H.; Nandwana, P.; Mcdaniels, R.; Dehoff, R.R.; Liaw, P.K.; Tryon, R.; Duty, C.E. Build orientation, surface roughness, and scan path influence on the microstructure, mechanical properties, and flexural fatigue behavior of Ti-6Al-4V fabricated by electron beam melting. Mater. Sci. Eng. A 2020, 772, 138740. [Google Scholar] [CrossRef]
  79. Li, J.; Cui, X.; Hooper, G.J.; Lim, K.S.; Woodfield, T.B.F. Rational design, bio-functionalization and biological performance of hybrid additive manufactured titanium implants for orthopaedic applications: A review. J. Mech. Behav. Biomed. Mater. 2020, 105, 103671. [Google Scholar] [CrossRef]
  80. Wang, Y.; Ke, C.; Wu, T.; Zhao, X.; Wang, R. Nanosecond laser texturing with hexagonal honeycomb micro-structure on Titanium for improved wettability and optical properties. Opt. Int. J. Light Electron Opt. 2019, 192, 162953. [Google Scholar] [CrossRef]
  81. Guimond-lischer, S.; Renolivier, Q.; Grunerbruno, B.; Maniura, K.; Guimond-lischer, S.; Ren, Q.; Braissant, O. Vacuum plasma sprayed coatings using ionic silver doped hydroxyapatite powder to prevent bacterial infection of bone implants. Biointerphases 2016, 11, 011012. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  82. Gunputh, U.F.; Le, H.; Handy, R.D.; Tredwin, C. Anodised TiO2 nanotubes as a scaffold for antibacterial silver nanoparticles on titanium implants. Mater. Sci. Eng. C 2018, 91, 638–644. [Google Scholar] [CrossRef] [PubMed]
  83. Rafieerad, A.R.; Bushroa, A.R.; Nasiri-tabrizi, B.; Vadivelu, J.; Yusof, F. Graphene oxide modified anodic ternary nanobioceramics on Ti6Al7Nb alloy for orthopedic and dental applications. Procedia Eng. 2017, 184, 409–417. [Google Scholar] [CrossRef]
  84. Murr, L.E. Strategies for creating living, additively manufactured, open-cellular metal and alloy implants by promoting osseointegration, osteoinduction and vascularization: An overview. J. Mater. Sci. Technol. 2018, 35, 231–241. [Google Scholar] [CrossRef]
  85. Bose, S.; Banerjee, D.; Shivaram, A.; Tarafder, S.; Bandyopadhyay, A. Calcium phosphate coated 3D printed porous titanium with nanoscale surface modification for orthopedic and dental applications. Mater. Des. 2018, 151, 102–112. [Google Scholar] [CrossRef]
  86. Bose, S.; Robertson, S.F.; Bandyopadhyay, A. Surface modification of biomaterials and biomedical devices using additive manufacturing. Acta Biomater. 2017, 66, 6–22. [Google Scholar] [CrossRef]
  87. Pobloth, A.; Checa, S.; Razi, H.; Petersen, A.; Weaver, J.C.; Windolf, M.; Tatai, A.Á.; Roth, C.P.; Schaser, K.; Duda, G.N.; et al. Mechanobiologically optimized 3D titanium-mesh scaffolds enhance bone regeneration in critical segmental defects in sheep. Sci. Transl. Med. 2018, 423, eaam8828. [Google Scholar] [CrossRef] [Green Version]
  88. Markhoff, J.; Wieding, J.; Weissmann, V.; Pasold, J.; Jonitz-Heincke, A.; Bader, R. Influence of different three-dimensional open porous titanium scaffold designs on human osteoblasts behavior in static and dynamic cell investigations. Materials (Basel) 2015, 8, 5490–5507. [Google Scholar] [CrossRef] [Green Version]
  89. Wang, Y.; Cai, X.; Huang, J.; Zhou, Y.; Jiang, T.; Wang, Y. Bone regeneration in critically sized rat mandible defects through the endochondral pathway using hydroxyapatite-coated 3D-printed Ti6Al4V scaffolds. RSC Adv. 2018, 8, 31745–31754. [Google Scholar] [CrossRef] [Green Version]
  90. Baggi, L.; Cappelloni, I.; Maceri, F.; Di Girolamo, M.; Vairo, G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A threedimensional finite element analysis. J. Prosthet. Dent. 2008, 100, 422–431. [Google Scholar] [CrossRef] [Green Version]
  91. Murr, L.E. A metallographic review of 3D printing/additive manufacturing of metal and alloy products and components. Metallogr. Microstruct. Anal. 2018, 6, 103–132. [Google Scholar] [CrossRef] [Green Version]
  92. Herzog, D.; Seyda, V.; Wycisk, E.; Emmelmann, C. Additive manufacturing of metals. Acta Mater. 2016, 117, 371–392. [Google Scholar] [CrossRef]
  93. Ni, J.; Ling, H.; Zhang, S.; Wang, Z.; Peng, Z. Three-dimensional printing of metals for biomedical applications. Mater. Today Bio. 2019, 3, 100024. [Google Scholar] [CrossRef] [PubMed]
  94. Bagehorn, S.; Wehr, J.; Maier, H.J. Application of mechanical surface finishing processes for roughness reduction and fatigue improvement of additively manufactured Ti-6Al-4V parts. Int. J. Fatigue 2017, 102, 135–142. [Google Scholar] [CrossRef]
  95. Fousov, M.; Vojtech, D.; Doubrava, K.; Daniel, M.; Lin, C. Influence of inherent surface and internal defects on mechanical properties of additively manufactured Ti6Al4V alloy: Comparison between selective laser melting and electron beam melting. Materials 2018, 11, 537. [Google Scholar] [CrossRef] [Green Version]
  96. Ataee, A.; Li, Y.; Wen, C. A comparative study on the nanoindentation behavior, wear resistance and in vitro biocompatibility of SLM manufactured CP-Ti and EBM manufactured Ti64 gyroid scaffolds. Acta Biomater. 2019, 97, 587–596. [Google Scholar] [CrossRef]
  97. Wennerberg, A. Effects of titanium surface topography on bone integration: A systematic review. Clin. Oral Implants Res. 2009, 4, 172–184. [Google Scholar] [CrossRef]
  98. Wysocki, B.; Maj, P.; Sitek, R.; Buhagiar, J. Laser and electron beam additive manufacturing methods of fabricating titanium bone implants. Appl. Sci. 2017, 7, 657. [Google Scholar] [CrossRef]
  99. Wang, H.; Zhao, B.; Liu, C.; Wang, C.; Tan, X.; Hu, M. A comparison of biocompatibility of a titanium alloy fabricated by electron beam melting and selective laser melting. PLoS ONE 2016, 11, e0158513. [Google Scholar] [CrossRef] [Green Version]
  100. Hara, D.; Nakashima, Y.; Sato, T.; Hirata, M.; Kanazawa, M. Bone bonding strength of diamond-structured porous titanium-alloy implants manufactured using the electron beam-melting technique. Mater. Sci. Eng. C 2016, 59, 1047–1052. [Google Scholar] [CrossRef]
  101. Biemond, J.E.; Hannink, G.; Verdonschot, N.; Buma, P. Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating. J. Mater. Sci. Mater. Med. 2013, 24, 745–753. [Google Scholar] [CrossRef] [PubMed]
  102. Ibrahim, H.; Jahadakbar, A.; Dehghan, A.; Moghaddam, N.S.; Amerinatanzi, A.; Elahinia, M. In vitro corrosion assessment of additively manufactured porous NiTi structures for bone. Metals (Basel) 2018, 8, 8030164. [Google Scholar]
  103. Ran, Q.; Yang, W.; Hu, Y.; Shen, X.; Yu, Y.; Xiang, Y.; Cai, K. Osteogenesis of 3D printed porous Ti6Al4V implants with different pore sizes. J. Mech. Behav. Biomed. Mater. 2018, 84, 1–11. [Google Scholar] [CrossRef]
  104. Taniguchi, N.; Fujibayashi, S.; Takemoto, M.; Sasaki, K.; Otsuki, B. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment. Mater. Sci. Eng. C 2016, 59, 690–701. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  105. Palmquist, A.; Snis, A.; Emanuelsson, L.; Browne, M.; Thomsen, P. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: Experimental studies in sheep. J. Biomater. Appl. 2013, 27, 1003–1016. [Google Scholar] [CrossRef] [PubMed]
  106. Chen, C.; Hao, Y.; Bai, X.; Ni, J.; Chung, S.; Liu, F.; Lee, I. 3D printed porous Ti6Al4V cage: Effects of additive angle on surface properties and biocompatibility, bone ingrowth in Beagle tibia model. Mater. Des. 2019, 175, 107824. [Google Scholar] [CrossRef]
  107. Wu, S.H.; Li, Y.; Zhang, Y.Q.; Li, X.K.; Yuan, C.F.; Hao, Y.L.; Zhang, Z.Y.; Guo, Z. Porous Titanium-6Aluminum-4Vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion. Artif. Organs 2013, 37, E191–E201. [Google Scholar] [CrossRef]
  108. Obaton, A.; Fain, J.; Djemaï, M.; Meinel, D.; Léonard, F.; Mahé, E.; Lécuelle, B.; Fouchet, J.; Bruno, G. In vivo XCT bone characterization of lattice structured implants fabricated by additive manufacturing. Heliyon 2017, 3, e00374. [Google Scholar] [CrossRef] [Green Version]
  109. Ponader, S.; Wilmowsky, C.; Widenmayer, M.; Lutz, R.; Heinl, P.; Korner, C.; Singer, R.F.; Nkenke, E.; Neukam, F.W.; Schlegel, K. In vivo performance of selective electron beam-melted Ti-6Al-4V structures. J. Biomed. Mater. Res. A 2009, 92, 56–62. [Google Scholar]
  110. Li, L.; Shi, J.; Zhang, K.; Yang, L. Early osteointegration evaluation of porous Ti6Al4V scaffolds designed based on triply periodic minimal surface models. J. Orthop. Transl. 2019, 19, 94–105. [Google Scholar] [CrossRef]
  111. Lee, B.; Lee, H.; Lee, K.; Kim, H.G.; Lee, C. Enhanced osseointegration of Ti6Al4V ELI screws built-up by electron beam additive manufacturing: An experimental study in rabbits. Appl. Surf. Sci. 2019, 508, 145160. [Google Scholar] [CrossRef]
  112. Chen, Z.; Yan, X.; Ying, S.; Liu, L.; Liu, X.; Zhao, G.; Ma, W.; Qi, W.; Ren, Z.; Liao, H.; et al. Influence of the pore size and porosity of selective laser melted Ti6Al4V ELI porous scaffold on cell proliferation, osteogenesis and bone ingrowth. Mater. Sci. Eng. C 2020, 106, 110289. [Google Scholar] [CrossRef] [PubMed]
  113. Tiainen, L.; Abreu, P.; Buciumeanu, M.; Silva, F.; Gasik, M.; Serna, R.; Carvalho, O. Novel laser surface texturing for improved primary stability of titanium implants. J. Mech. Behav. Biomed. Mater. 2019, 98, 26–39. [Google Scholar] [CrossRef] [PubMed]
  114. Voisey, K.T.; Scotchford, C.A.; Martin, L.; Gill, H.S. Effect of Q-switched laser surface texturing of titanium on osteoblast cell response. Phys. Procedia 2014, 56, 1126–1135. [Google Scholar] [CrossRef]
  115. Kümmel, D.; Hamann-schroer, M.; Hetzner, H.; Schneider, J. Tribological behavior of nanosecond-laser surface textured Ti6Al4V. Wear 2019, 422–423, 261–268. [Google Scholar] [CrossRef] [Green Version]
  116. Patel, S.D.; Singh, A.; Balani, K.; Ramkumar, J. Topographical effects of laser surface texturing on various time-dependent wetting regimes in Ti6Al4V. Surf. Coat. Technol. 2018, 349, 816–829. [Google Scholar] [CrossRef]
  117. Chen, J.; Mwenifumbo, S.; Langhammer, C.; Mcgovern, J.; Li, M.; Beye, A.; Soboyejo, W.O. Cell/Surface interactions and adhesion on Ti-6Al-4V: Effects of surface texture. J. Biomed. Mater. Res. B Appl. Biomater. 2007, 82, 360–373. [Google Scholar] [CrossRef]
  118. Mwenifumbo, S.; Li, M.; Chen, J.; Wol, A.B. Cell/Surface interactions on laser micro-textured titanium-coated silicon surfaces. J. Mater. Sci. Mater. Med. 2007, 18, 9–23. [Google Scholar] [CrossRef]
  119. Gamboa, J.R.; Mohandes, S.; Tran, P.L.; Slepian, M.J.; Yoon, J. Liner fibroblast alignment on sinusoidal wave micropatterns. Colloids Surf. B Biointerfaces 2013, 104, 318–325. [Google Scholar] [CrossRef] [Green Version]
  120. Soboyejo, W.O.; Nemetski, B.; Allameh, S.; Marcantonio, N.; Mercer, C.; Ricci, J. Interactions between MC3T3-E1 cells and textured Ti6Al4V surfaces. J. Biomed. Mater. Res. 2002, 62, 56–72. [Google Scholar] [CrossRef]
  121. Chen, J.; Ulerich, J.P.; Abelev, E.; Fasasi, A.; Arnold, C.B.; Soboyejo, W.O. An investigation of the initial attachment and orientation of osteoblast-like cells on laser grooved Ti-6Al-4V surfaces. Mater. Sci. Eng. C 2009, 29, 1442–1452. [Google Scholar] [CrossRef]
  122. Brånemark, R.; Emanuelsson, L.; Palmquist, A.; Thomsen, P. Bone response to laser-induced micro- and nano-size titanium surface features. Nanomed. Nanotechnol. Biol. Med. 2011, 7, 220–227. [Google Scholar] [CrossRef] [PubMed]
  123. Yu, Z.; Yang, G.; Zhang, W.; Hu, J. Investigating the effect of picosecond laser texturing on microstructure and biofunctionalization of titanium alloy. J. Mater. Process. Technol. 2018, 255, 129–136. [Google Scholar] [CrossRef]
  124. Anselme, K.; Linez, P.; Bigerelle, M.; Le Maguer, D.; Le Maguer, A.; Hardouin, P.; Hildebrand, H.F.; Iost, A.; Leroy, J.M. The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour. Biomaterials 2000, 21, 1567–1577. [Google Scholar] [CrossRef]
  125. Ricci, J.L.; Alexander, H. Laser microtexturing of implant surfaces for enhanced tissue integration. Eng. Mater. 2011, 198–199, 179–202. [Google Scholar] [CrossRef]
  126. Kumari, R.; Scharnweber, T.; Pfleging, W.; Besser, H.; Dutta, J. Laser surface textured titanium alloy (Ti-6Al-4V)-PartII—Studies on bio-compatibility. Appl. Surf. Sci. 2015, 357, 750–758. [Google Scholar] [CrossRef]
  127. Pfleging, W.; Kumari, R.; Besser, H.; Scharnweber, T.; Dutta, J. Laser surface textured titanium alloy (Ti-6Al-4V): Part 1—Surface characterization. Appl. Surf. Sci. 2015, 355, 104–111. [Google Scholar] [CrossRef]
  128. Cunha, A.; Elie, A.; Plawinski, L.; Paula, A.; Maria, A.; Almeida, A.; Urdaci, M.C.; Durrieu, M.; Vilar, R. Femtosecond laser surface texturing of titanium as a method to reduce the adhesion of Staphylococcus aureus and biofilm formation. Appl. Surf. Sci. 2016, 360, 485–493. [Google Scholar] [CrossRef]
  129. Davies, D. Understanding biofilm resistance to antibacterial agents. Nat. Rev. Drug Discov. 2003, 2, 114–122. [Google Scholar] [CrossRef]
  130. Galarraga-Vinueza, M.E.; Mesquita-Guimarães, J.; Magini, R.S.; Souza, J.C.M.; Fredel, M.C.; Boccaccini, A.R. Anti-biofilm properties of bioactive glasses embedding organic active compounds. J. Bio. Mater. Res. Part A 2016. [Google Scholar] [CrossRef]
  131. Souza, J.C.M.; Mota, R.R.C.; Sordi, M.B.; Bernardo, B. Biofilm formation on different materials used in oral rehabilitation. Braz. Dent. J. 2016, 27, 141–147. [Google Scholar] [CrossRef] [PubMed]
  132. Xavier, J.G.; Geremias, T.C.; Montero, J.F.D.; Vahey, B.R.; Benfatti, C.A.M.; Souza, J.C.M.; Magini, R.S.; Pimenta, A.L. Lactam inhibiting Streptococcus mutans growth on titanium. Mater. Sci. Eng. C 2016, 68, 837–841. [Google Scholar] [CrossRef] [PubMed]
  133. Gehrke, S.A.; Taschieri, S.; Del Fabbro, M.; Coelho, P.G. The positive biomechanical effects of titanium oxide for sandblasting implant surface as an alternative to aluminium oxide. J. Oral Implantol. 2013, 41, 141208072802005. [Google Scholar] [CrossRef] [PubMed]
  134. Medvedev, A.E.; Ng, H.P.; Lapovok, R.; Estrin, Y.; Lowe, T.C.; Anumalasetty, V.N. Effect of bulk microstructure of commercially pure titanium on surface characteristics and fatigue properties after surface modification by sand blasting and acid-etched. J. Mech. Beh. Biomed Mater. 2016, 57, 55–68. [Google Scholar] [CrossRef] [PubMed]
  135. Aparicio, C.; Gil, F.J.; Fonseca, C.; Barbosa, M.; Anton, J. Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications. Biomaterials 2003, 24, 263–273. [Google Scholar] [CrossRef]
  136. Ivanoff, C.J.; Hallgren, C.; Widmark, G.; Sennerby, L.; Wennerberg, A. Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans. Clin. Oral Implants Res. 2001, 12, 128–134. [Google Scholar] [CrossRef]
  137. Rasmusson, L.; Kahnberg, K.; Tan, A. Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible. Implant Dent. Relat. Res. 2001, 3, 2–8. [Google Scholar] [CrossRef]
  138. Gotfredsen, K.; Karlsson, U. A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface. J. Prosthodont. 2001, 10, 2–7. [Google Scholar] [CrossRef]
  139. Astrand, P.; Engquist, B.; Dahlgren, S.; Engquist, E.; Feldmann, H.; Gröndahl, K. Astra tech and brånemark system implants: A prospective 5-year comparative study. Results after one year. Clin. Implant Dent. Relat. Res. 2010, 1, 17–26. [Google Scholar] [CrossRef]
  140. van Steenberghe, D.; De Mars, G.; Quirynen, M.; Jacobs, R.; Naert, I.A.; Jacobs, R. A prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems. Clin. Oral Implants Res. 2000, 11, 202–209. [Google Scholar] [CrossRef]
  141. Wennerberg, A.; Albrektsson, T.; Andersson, B.; Krol, J.J. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin. Oral Implants Res 1995, 6, 24–30. [Google Scholar] [CrossRef] [PubMed]
  142. Abron, A.; Hopfensperger, M.; Thompson, J.; Cooper, L.F. Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model. Prosthet. Dent. 2001, 85, 40–46. [Google Scholar] [CrossRef] [PubMed]
  143. Gross, U. Evaluation of the interface between bone and titanium surfaces being blasted by aluminium oxide or bioceramic particles. Clin. Oral Implants Res 2003, 17, 349–356. [Google Scholar]
  144. Piattelli, M.; Scarano, A.; Paolantonio, M.; Iezzi, G.; Piattelli, A. Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits. J. Oral Implantol. 2002, 28, 2–8. [Google Scholar] [CrossRef] [Green Version]
  145. Delaunay, C. Effect of hydroxyapatite coating on the radio-clinical results of a grit-blasted titanium alloy femoral taper. A case-control study of 198 cementless primary total hip arthroplasty with the Alloclassic TM system. Orthop. Traumatol. Surg. Res. 2014, 100, 739–744. [Google Scholar] [CrossRef] [Green Version]
  146. Napoli, A.; Wieland, M.; Textor, M.; Spencer, N.D. Comparative investigation of the surface properties of commercial titanium dental implants. Part I: Chemical composition. Mater. Sci. Mater. Med. 2002, 13, 535–548. [Google Scholar]
  147. Zinger, O.; Anselme, K.; Denzer, A.; Habersetzer, P.; Wieland, M.; Jeanfils, J. Time-dependent morphology and adhesion of osteoblastic cells on titanium model surfaces featuring scale-resolved topography. Biomaterials 2004, 25, 2695–2711. [Google Scholar] [CrossRef]
  148. Wennerberg, A.; Svanborg, L.M.; Berner, S.; Andersson, M. Spontaneously formed nanostructures on titanium surfaces. Clin. Oral Implants Res. 2013, 24, 203–209. [Google Scholar] [CrossRef]
  149. Buser, D.; Weingart, D.; Stuttgart, K.; Jones, A.; Oates, T.W. A 5-year prospective multicenter study of early loaded titanium implants with a sandblasted and acid-etched surface. Inter. J. Oral Maxillofac. Implants 2011, 26, 1324–1332. [Google Scholar]
  150. Zahran1, R.; Leal, J.I.R.; Valverde, M.A.R.; Vi´lchez, M.A.C. Effect of hydrofluoric acid etching time on titanium topography, chemistry, wettability, and cell adhesion. PLoS ONE 2016, 11, e0165296. [Google Scholar] [CrossRef]
  151. Yokoyama, K.; Ichikawa, T.; Murakami, H.; Miyamoto, Y.; Asaoka, K. Fracture mechanisms of retrieved titanium screw thread in dental implant. Biomaterials 2002, 23, 2459–2465. [Google Scholar] [CrossRef]
  152. Cho, S.-A.; Park, K.-T. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching. Biomaterials 2003, 24, 3611–3617. [Google Scholar] [CrossRef]
  153. Park, J.Y.; Davies, J.E. Red blood cell and platelet interactions with titanium implant surfaces. Clin. Oral Implants Res. 2000, 11, 530–539. [Google Scholar] [CrossRef] [PubMed]
  154. Trisi, P.; Trisi, P.; Lazzara, R.; Rebaudi, A.; Rao, W.; Testori, T.; Porter, S.S. Bone-implant contact on machined and dual acid-etched surfaces after 2 months of healing in the human maxilla bone-implant contact on machined and dual acid-etched surfaces after 2 months of healing in the human maxilla. J. Periodontol. 2003, 74, 945–956. [Google Scholar] [CrossRef] [PubMed]
  155. Davies, J. Mechanisms of endosseous integration. Int. J. Prosthodont. 1998, 11, 391–401. [Google Scholar] [PubMed]
  156. Cochran, D.; Schenk, R.; Lussi, A.; Higginbottom, F.; Buser, D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J. Biomed. Mater. Res. 1998, 40, 1–11. [Google Scholar] [CrossRef]
  157. Suzuki, M.; Guimaraes, M.V.M.; Marin, C.; Granato, R.; Fernandes, C.A.O.; Gil, J.N.; Coelho, P.G. Histomorphologic and bone-to-implant contact evaluation of dual acid-etched and bioceramic grit-blasted implant surfaces: An experimental study in dogs. J. Oral Maxillofac. Surg. 2010, 68, 1877–1883. [Google Scholar] [CrossRef]
  158. Ellingsen, J.E. Pretreatment of titanium implants with fluoride improves their retention in bone. J. Mater. Sci. 1995, 6, 749–753. [Google Scholar]
  159. Cooper, L.F.; Takabe, J.; Guo, J.; Abron, A.; Holmen, A.; Ellingsen, J.E. Fluoride modification effects on osteoblast behavior and bone formation at TiO2 grit-blasted c.p. titanium endosseous implants. Biomaterials 2006, 27, 926–936. [Google Scholar] [CrossRef]
  160. Ellingsen, J.E.; Johansson, C.B.; Wennerberg, A.; Anders, H. Improved retention and bone-to-implant contact with fluoride-modified titanium implants. Inter. J. Oral Maxillofac. Implants 2004, 19, 659–666. [Google Scholar]
  161. Nelson, C.; André, M.; Valiev, R.Z.; Neves, S. Ultrafine grained titanium for biomedical applications: An overview of performance. Integr. Med. Res. 2013, 2, 340–350. [Google Scholar]
  162. Elias, C.N.; Meirelles, L. Improving osseointegration of dental implants. Expert Rev. Med. Devices 2010, 7, 241–256. [Google Scholar] [CrossRef] [PubMed]
  163. Nagasawa, M.; Cooper, L.F.; Ogino, Y.; Mendonca, D.; Liang, R. Topography influences adherent cell regulation of osteoclastogenesis topography influences adherent cell regulation of osteoclastogenesis. J. Dent. Res. 2015, 95, 319–326. [Google Scholar] [CrossRef]
  164. Ziebart, T.; Schnell, A.; Walter, C. Interactions between endothelial progenitor cells (EPC) and titanium implant surfaces. Clin. Oral Investig. 2013, 17, 301–309. [Google Scholar] [CrossRef] [PubMed]
  165. Lagonegro, P.; Trevisi, G.; Nasi, L.; Parisi, L.; Manfredi, E. Osteoblasts preferentially adhere to peaks on micro-structured titanium Osteoblasts preferentially adhere to peaks on micro-structured titanium. Dent. Mater. 2018, 37, 278–285. [Google Scholar] [CrossRef] [Green Version]
  166. Wang, X.; Wang, Y.; Bosshardt, D.D.; Miron, R.J.; Zhang, Y. The role of macrophage polarization on fibroblast behavior-an in vitro investigation on titanium surfaces. Clin. Oral Investig. 2017, 22, 847–857. [Google Scholar] [CrossRef]
  167. Zhang, J.; Liu, J.; Wang, C.; Chen, F.; Wang, X.; Lin, K. A comparative study of the osteogenic performance between the hierarchical micro/submicro-textured 3D-printed Ti6Al4V surface and the SLA surface. Bioact. Mater. 2020, 5, 9–16. [Google Scholar] [CrossRef]
  168. Oates, T.W.; Alexander, P.P.; Schoolfield, J.D.; Mcmahan, C.A. Conventional SLA and chemically modified SLA implants in patients with poorly controlled type 2 Diabetes mellitus—A randomized controlled trial. Clin. Oral Implants Res. 2011, 24, 13–19. [Google Scholar]
  169. Shibli, J.A.; Eduardo, C.; Preshaw, P.M. Efficacy of standard (SLA) and modified sandblasted and acid-etched (SLActive) dental implants in promoting immediate and/or early occlusal loading protocols: A systematic review of prospective studies. Clin. Oral Implants Res. 2015, 26, 359–370. [Google Scholar]
  170. Chiang, H.J.; Hsu, H.J.; Peng, P.W.; Wu, C.Z.; Ou, K.L.; Cheng, H.Y.; Walinski, C.J.; Sugiatno, E. Early bone response to machined, sandblasting acid etching (SLA) and novel surface-functionalization (SLAffinity) titanium implants: Characterization, biomechanical analysis and histological evaluation in pigs. J. Bio. Mater. Res. Part A 2016, 104, 397–405. [Google Scholar] [CrossRef]
  171. Vasak, C.; Busenlechner, D.; Schwarze, U.Y.; Leitner, H.F.; Guzon, F.M.; Hefti, T.; Schlottig, F.; Gruber, R. Early bone apposition to hydrophilic and hydrophobic titanium implant surfaces: A histologic and histomorphometric study in minipigs. Clin. Oral Implants Res. 2014, 25, 1378–1385. [Google Scholar] [CrossRef] [PubMed]
  172. Alfarsi, M.A.; Hamlet, S.M.; Ivanovski, S. Titanium surface hydrophilicity modulates the human macrophage inflammatory cytokine response. J. Biomed. Mater. Res. Part A 2014, 102, 60–67. [Google Scholar] [CrossRef] [PubMed]
  173. Wennerberg, A.; Jimbo, R.; Stübinger, S.; Obrecht, M.; Dard, M.; Berner, S. Nanostructures and hydrophilicity influence osseointegration: A biomechanical study in the rabbit tibia. Clin. Oral Implants Res. 2014, 25, 1041–1050. [Google Scholar] [CrossRef] [PubMed]
  174. Alayan, J.; Vaquette, C.; Saifzadeh, S.; Hutmacher, D.; Ivanovski, S. Comparison of early osseointegration of SLA® and SLActive® implants in maxillary sinus augmentation: A pilot study. Clin. Oral Implants Res. 2016, 28, 1325–1333. [Google Scholar] [CrossRef] [PubMed]
  175. Kammerer, P.W.; Gabriel, M.; Al-Nawas, B.; Scholz, T.; Kirchmaier, C.M.; Klein, M.O. Early implant healing: Promotion of platelet activation and cytokine release by topographical, chemical and biomimetical titanium surface modifications in vitro. Clin. Oral Implants Res. 2012, 23, 504–510. [Google Scholar] [CrossRef] [PubMed]
  176. Kopf, B.S.; Schipanski, A.; Rottmar, M.; Berner, S.; Maniura-weber, K. Enhanced differentiation of human osteoblasts on Ti surfaces pre-treated with human whole blood. Acta Biomater. 2015, 19, 180–190. [Google Scholar] [CrossRef] [PubMed]
  177. Abdel-Haq, J.; Karabuda, C.Z.; Arisan, V.; Mutlu, Z.; Kurkcu, M. Osseointegration and stability of a modified sand-blasted acid-etched implant: An experimental pilot study in sheep. Clin. Oral Implants Res. 2010, 22, 265–274. [Google Scholar] [CrossRef]
  178. Hyzy, S.L.; Olivares-navarrete, R.; Ortman, S.; Boyan, B.D.; Schwartz, Z. BMP2 alters osteogenesis and anti-inflammatory profiles of mesenchymal stem cells induced by microtextured titanium in vitro. Tissue Eng. Part A 2017, 23, 1132–1141. [Google Scholar] [CrossRef]
  179. Lang, N.P.; Salvi, G.E.; Huynh-Ba, G.; Ivanovski, S.; Donos, N.; Bosshardt, D.D. Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans. Clin. Oral Implants Res. 2011, 22, 349–356. [Google Scholar] [CrossRef]
  180. Karabuda, Z.C.; Abdel-Haq, J.; Arisan, V. Stability, marginal bone loss and survival of standard and modified sand-blasted, acid-etched implants in bilateral edentulous spaces: A prospective 15-month evaluation. Clin. Oral Implants Res. 2011, 22, 840–849. [Google Scholar] [CrossRef]
  181. Kulterer, B.; Friedl, G.; Jandrositz, A.; Sanchez-cabo, F.; Prokesch, A.; Paar, C.; Scheideler, M.; Windhager, R.; Preisegger, K.; Trajanoski, Z. Gene expression profiling of human mesenchymal stem cells derived from bone marrow during expansion and osteoblast differentiation. BMC Genom. 2007, 8, 70. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  182. Lai, H.-C.; Zhuang, L.-F.; Zhang, Z.-Y.; Wieland, M.; Liu, X. Bone apposition around two different sandblasted, large-grit and acid-etched implant surfaces at sites with coronal circumferential defects: An experimental study in dogs. Clin. Oral Implants Res. 2009, 20, 247–253. [Google Scholar] [CrossRef]
  183. Bornstein, M.M.; Hart, C.N.; Halbritter, S.A.; Morton, D.; Buser, D. Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stabil. Clin. Implant Dent. Relat. Res. 2009, 11, 338–347. [Google Scholar] [CrossRef] [PubMed]
  184. Bosshardt, D.D.; Chappuis, V.; Buser, D. Osseointegration of titanium, titanium alloy and zirconia dental implants: Current knowledge and open questions. Periodontology 2017, 73, 22–40. [Google Scholar] [CrossRef] [PubMed]
  185. Fischer, K.; Stenberg, T. Prospective 10-year cohort study based on a randomized, controlled trial (RCT) on prostheses. Part II: Prosthetic outcomes. Clin. Implant Dent. Relat. Res. 2013, 15, 498–508. [Google Scholar] [CrossRef]
  186. Roccuzzo, M.; Bonino, L.; Dalmasso, P.; Aglietta, M. Long-term results of a three arms prospective cohort study on implants in periodontally compromised patients: 10-year data around sandblasted and acid-etched (SLA) surface. Br. Dent. J. 2015, 25, 1105–1112. [Google Scholar] [CrossRef] [PubMed]
  187. Giavaresi, G.; Fini, M.; Cigada, A.; Chiesa, R.; Rondelli, G.; Rimondini, L.; Torricelli, P.; Aldini, N.N.; Giardino, R. Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone. Biomaterials 2003, 24, 1583–1594. [Google Scholar] [CrossRef]
  188. Urban, R.M.; Jacobs, J.J.; Tomlinson, M.J.; Gavrilovic, J.; Peoc’H, M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J. Bone Jt. Surg. 2000, 82, 457–476. [Google Scholar] [CrossRef]
  189. Browne, M.; Gregson, P.J. Effect of mechanical surface pretreatment on metal ion release. Biomaterials 2000, 21, 385–392. [Google Scholar] [CrossRef]
  190. Loughlin, R.M. Early loading of sandblasted and acid-etched (SLA) implants: A prospective split-mouth comparative study. Clin. Oral Implants Res. 2010, 12, 572–578. [Google Scholar] [CrossRef]
  191. Taba, M.; Novaes, A.B.; Souza, S.L.S.; Grisi, M.F.M.; Palioto, D.B.; Pardini, L.C. Radiographic evaluation of dental implants with different surface treatments: An experimental study in dogs. Implant Dent. 2003, 12, 252–258. [Google Scholar] [CrossRef] [PubMed]
  192. Li, B.; Liu, X.; Meng, F.; Chang, J.; Ding, C. Preparation and antibacterial properties of plasma sprayed nano-titania/silver coatings. Mater. Chem. Phys. 2009, 118, 99–104. [Google Scholar] [CrossRef]
  193. Zhang, W.; Gu, J.; Zhang, C.; Xie, Y.; Zheng, X. Preparation of titania coating by induction suspension plasma spraying for biomedical application. Surf. Coat. Technol. 2019, 358, 511–520. [Google Scholar] [CrossRef]
  194. Ke, D.; Vu, A.A.; Bandyopadhyay, A.; Bose, S. Compositionally graded doped hydroxyapatite coating on titanium using laser and plasma spray deposition for bone implants. Acta Biomater. 2019, 84, 414–423. [Google Scholar] [CrossRef]
  195. Kumari, R.; Majumdar, J.D. Studies on corrosion resistance and bio-activity of plasma spray deposited hydroxylapatite (Ha) based TiO2 and ZrO2 dispersed composite coatings on titanium alloy (Ti-6Al-4V) and the same after post spray heat treatment. Appl. Sur. Sci. 2017, 420, 935–943. [Google Scholar] [CrossRef]
  196. Kumari, R.; Majumdar, J.D. Microstructure and surface mechanical properties of plasma spray deposited and post spray heat treated hydroxyapatite (HA) based composite coating on titanium alloy (Ti-6Al-4V) substrate. Mater. Charact. 2017, 131, 12–20. [Google Scholar] [CrossRef]
  197. Vu, A.A.; Robertson, S.F.; Ke, D.; Bandyopadhyay, A.; Bose, S. Mechanical and biological properties of ZnO, SiO2, and Ag2O doped plasma sprayed hydroxyapatite coating for orthopaedic and dental applications. Acta Biomater. 2019, 92, 325–335. [Google Scholar] [CrossRef]
  198. Alves, S.A.; Patel, S.B.; Sukotjo, C.; Mathew, M.T.; Filho, P.N.; Celis, J.-P.; Rocha1, L.A.; Shokuhfar, T. Synthesis of calcium-phosphorous doped TiO2 nanotubes by anodization and reverse polarization: A promising strategy for an efficient biofunctional implant surface. Appl. Surf. Sci. 2016, 399, 682–701. [Google Scholar] [CrossRef]
  199. Ma, M.; Liu, J.; Wu, Z.; Zheng, X.; Hu, X.; Li, X. Progress of studies on fabrication of TiO2 nanotube arrays on Ti or Ti alloys by anodization. Adv. Mater. Res. 2014, 941–944, 441–444. [Google Scholar] [CrossRef]
  200. Yao, C.; Perla, V.; Mckenzie, J.L.; Slamovich, E.B.; Webster, T.J. Anodized Ti and Ti6Al4V possessing nanometer surface features enhances osteoblast adhesion. J. Biomed. Nanotechnol. 2005, 1, 68–73. [Google Scholar] [CrossRef]
  201. Albrektsson, T. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin. Oral Implants Res. 2002, 13, 252–259. [Google Scholar]
  202. Jungner, M.; Lundqvist, P.; Lundgren, S. Oxidized titanium implants (Nobel Biocare TiUnite) compared with turned titanium implants (Nobel Biocare mark III) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol. Clin. Oral Implants Res. 2005, 16, 308–312. [Google Scholar] [CrossRef] [PubMed]
  203. Schüpbach, P.; Glauser, R.; Rocci, A.; Martignoni, M.; Sennerby, L.; Lundgren, A.; Gottlow, J. The human bone-oxidized titanium implant interface: A light microscopic, scanning electron microscopic, back-scatter scanning electron microscopic, and energy-dispersive X-ray study of clinically retrieved dental implants. Clin. Implant Dent. Relat. Res 2005, 7, S36–S43. [Google Scholar] [CrossRef] [PubMed]
  204. Sul, Y.T.; Byon, E.S.; Jeong, Y.Y. Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone: Effect of calcium surface chemistry of a novel implant. Clin. Implant Dent. Relat. Res. 2004, 6, 101–110. [Google Scholar] [CrossRef]
  205. Sul, Y.T.; Johansson, C.B.; Albrektsson, T. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone. Int. J. Oral Maxillofac. Implants 2002, 17, 625–634. [Google Scholar]
  206. Grotberg, J.; Hamlekhan, A.; Butt, A.; Patel, S.; Royhman, D.; Shokuhfar, T.; Sukotjo, C.; Takoudis, C.; Mathew, M.T. Thermally oxidized titania nanotubes enhance the corrosion resistance of Ti6Al4V. Mater. Sci. Eng. C Mater. Biol. Appl. 2016, 59, 677–689. [Google Scholar] [CrossRef]
  207. Shin, D.H.; Shokuhfar, T.; Choi, C.K.; Lee, S.-H.; Friedrich, C. Wettability changes of TiO2 nanotube surfaces. Nanotechnology 2011, 22, 315704. [Google Scholar] [CrossRef]
  208. Beltrán-Partida, E.; Moreno-Ulloa, A.; Valdez-Salas, B.; Velasquillo, C.; Carrillo, M.; Escamilla, A.; Valdez, E.; Villarreal, F. Improved osteoblast and chondrocyte adhesion and viability by surface-modified Ti6Al4V alloy with anodized TiO2 nanotubes using a super-oxidative solution. Materials (Basel) 2015, 8, 867–883. [Google Scholar] [CrossRef] [Green Version]
  209. Beltrán-Partida, E.; Valdez-Salas, B.; Escamilla, A.; Curiel, M.; Valdez-Salas, E.; Nedev, N.; Bastidas, J.M. Disinfection of titanium dioxide nanotubes using super-oxidized water decrease bacterial viability without disrupting osteoblast behavior. Mater. Sci. Eng. C 2016, 60, 239–245. [Google Scholar] [CrossRef] [Green Version]
  210. Li, H.; Cui, Q.; Feng, B.; Wang, J.; Lu, X.; Weng, J. Antibacterial activity of TiO2 nanotubes: Influence of crystal phase, morphology and Ag deposition. Appl. Surf. Sci. 2013, 284, 179–183. [Google Scholar] [CrossRef]
  211. Liu, W.; Su, P.; Iii, A.G.; Chen, S.; Wang, N.; Wang, J.; Li, H.; Zhang, Z. Optimizing stem cell functions and antibacterial properties of TiO2 nanotubes incorporated with ZnO nanoparticles: Experiments and modeling. Int. J. Nanomed. 2015, 10, 1997–2019. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  212. Quirynen, M.; Van Assche, N. RCT comparing minimally with moderately rough implants. Part 2: Microbial observations. Clin. Oral Implants Res. 2012, 23, 625–634. [Google Scholar] [CrossRef] [PubMed]
  213. Brammer, K.S.; Oh, S.; Cobb, C.J.; Bjursten, L.M.; Heyde, H.V.D.; Jin, S. Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface. Acta Biomater. 2009, 5, 3215–3223. [Google Scholar] [CrossRef] [PubMed]
  214. Li, G.; Cao, H.; Zhang, W.; Ding, X.; Yang, G.; Qiao, Y.; Liu, X.; Jiang, X. Enhanced osseointegration of hierarchical micro/nano-topographic titanium fabricated by micro-arc oxidation and electrochemical treatment. ACS Appl. Mater. Interfaces 2016, 8, 3840–3852. [Google Scholar] [CrossRef] [PubMed]
  215. Zhao, L.; Liu, L.; Wu, Z.; Zhang, Y.; Chu, P.K. Effects of micropitted/nanotubular titania topographies on bone mesenchymal stem cell osteogenic differentiation. Biomaterials 2012, 33, 2629–2641. [Google Scholar] [CrossRef] [PubMed]
  216. Wang, N.; Li, H.; Lü, W.; Li, J.; Wang, J.; Zhang, Z.; Liu, Y. Effects of TiO2 nanotubes with different diameters on gene expression and osseointegration of implants in minipigs. Biomaterials 2011, 32, 6900–6911. [Google Scholar] [CrossRef]
  217. Su, E.P.; Justin, D.F.; Pratt, C.R.; Sarin, V.K. Effects of titanium nanotubes on the osseointegration, cell differentiation, mineralisation and antibacterial properties of orthopaedic implant surfaces. Bone Jt. J. 2018, 100, 9–16. [Google Scholar] [CrossRef]
  218. Salou, L.; Hoornaert, A.; Louarn, G.; Layrolle, P. Enhanced osseointegration of titanium implants with nanostructured surfaces: An experimental study in rabbits. Acta Biomater. 2015, 11, 494–502. [Google Scholar] [CrossRef]
  219. von Wilmowsky, C.; Bauer, S.; Roedl, S.; Neukam, F.W.; Schmuki, P.; Schlegel, K.A. The diameter of anodic TiO2 nanotubes affects bone formation and correlates with the bone morphogenetic protein-2 expression in vivo. Clin. Oral Implants Res. 2012, 23, 359–366. [Google Scholar] [CrossRef]
  220. Butt, A.; Hamlekhan, A.; Patel, S.; Royhman, D.; Sukotjo, C.; Mathew, M.; Shokuhfar, T.; Takoudis, C. A novel investigation of the formation of TiO2 nanotubes on thermally formed oxide of Ti-6Al-4V. J. Oral Implantol. 2015, 41, 523–531. [Google Scholar] [CrossRef]
  221. Yu, W.; Jiang, X.; Zhang, F.; Xu, L. The effect of anatase TiO2 nanotube layers on MC3T3-E1 preosteoblast adhesion, proliferation, and differentiation. J. Biomed. Mater. Res. Part A 2010, 94. [Google Scholar] [CrossRef] [PubMed]
  222. Giordano, C.; Saino, E.; Rimondini, L.; Pedeferri, M.P.; Visai, L.; Cigada, A.; Chiesa, R. Electrochemically induced anatase inhibits bacterial colonization on Titanium Grade 2 and Ti6Al4V alloy for dental and orthopedic devices. Colloids Surf. B Biointerfaces 2011, 88, 648–655. [Google Scholar] [CrossRef] [PubMed]
  223. Oh, S.; Daraio, C.; Chen, L.-H.; Pisanic, T.R.; Fiñones, R.R.; Jin, S. Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes. J. Biomed. Mater. Res. A 2006, 78, 97–103. [Google Scholar] [CrossRef] [PubMed]
  224. Wang, Q.; Huang, J.-Y.; Li, H.-Q.; Zhao, A.Z.-J.; Wang, Y.; Zhang, K.-Q.; Sun1, H.-T.; Lai, Y.-K. Recent advances on smart TiO2 nanotube platforms for sustainable drug delivery applications. Int. J. Nanomed. 2016, 151–165. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Figure 1. Structure of skeleton: descending hierarchical macro- to nano-scale structures of natural bone. (Reproduced with permission from [62]. Copyright Elsevier, 2016).
Figure 1. Structure of skeleton: descending hierarchical macro- to nano-scale structures of natural bone. (Reproduced with permission from [62]. Copyright Elsevier, 2016).
Nanomaterials 10 01244 g001
Figure 2. (a) Schematics of a laser beam melting (LBM) machine; (bd) porous structures; (ef) micro-CT images of human cancellous bones; (g) stacked hollow cubes; (hi) the surgical template in pre-blasting and after blasting condition; (j) the dental restorations; (k) a personalized femoral component. (Reproduced with permission from [93]. Copyright Elsevier, 2019).
Figure 2. (a) Schematics of a laser beam melting (LBM) machine; (bd) porous structures; (ef) micro-CT images of human cancellous bones; (g) stacked hollow cubes; (hi) the surgical template in pre-blasting and after blasting condition; (j) the dental restorations; (k) a personalized femoral component. (Reproduced with permission from [93]. Copyright Elsevier, 2019).
Nanomaterials 10 01244 g002
Figure 3. (a) XTT (Dimethoxazole yellow) results of cell viability of MC3T3-E1 fibroblast cells after 24 h in contact with the extracts in the as-received and laser textured surface; (b,c) SEM of the surface of linear geometry and dimple geometry; (df) fluorescent micrographs of the as-received, line geometry and dimple geometry showing the attachment of MC3T3-E1 cells. (Reproduced with permission from [126]. Copyright Elsevier, 2015).
Figure 3. (a) XTT (Dimethoxazole yellow) results of cell viability of MC3T3-E1 fibroblast cells after 24 h in contact with the extracts in the as-received and laser textured surface; (b,c) SEM of the surface of linear geometry and dimple geometry; (df) fluorescent micrographs of the as-received, line geometry and dimple geometry showing the attachment of MC3T3-E1 cells. (Reproduced with permission from [126]. Copyright Elsevier, 2015).
Nanomaterials 10 01244 g003
Figure 4. (a) Standard version (grit-blasting); (b) HA coating on standard version; (c) straight Alloclassic™ THA in a 57-year-old female patient for nonunion of a fracture of the femoral neck after removing fixation hardware: immediate postoperative control; (d) radiographic result after 23 years and 3 months of follow-up at the age of 80 years old and 5 months. (Reproduced with permission from [145]. Copyright Elsevier, 2014).
Figure 4. (a) Standard version (grit-blasting); (b) HA coating on standard version; (c) straight Alloclassic™ THA in a 57-year-old female patient for nonunion of a fracture of the femoral neck after removing fixation hardware: immediate postoperative control; (d) radiographic result after 23 years and 3 months of follow-up at the age of 80 years old and 5 months. (Reproduced with permission from [145]. Copyright Elsevier, 2014).
Nanomaterials 10 01244 g004
Figure 5. Typical dental implant surface morphology using acid-etching. (Reproduced with permission from [161]. Copyright Elsevier, 2013).
Figure 5. Typical dental implant surface morphology using acid-etching. (Reproduced with permission from [161]. Copyright Elsevier, 2013).
Nanomaterials 10 01244 g005
Figure 6. (a) Representative histological images of 3D, 3DA, and SLA implants after implantation for 3 and 6 weeks, respectively (scale bar = 200 μm); (b) quantification of BIC percentages on implant surfaces; (c) SEM of 3D, 3DA, and SLA surfaces; (d) cell morphology on the 3DA surface after culturing of bone marrow stromal cells (BMSCs) for 24 h observed using SEM. (Reproduced with permission from [167]. Copyright Elsevier, 2020).
Figure 6. (a) Representative histological images of 3D, 3DA, and SLA implants after implantation for 3 and 6 weeks, respectively (scale bar = 200 μm); (b) quantification of BIC percentages on implant surfaces; (c) SEM of 3D, 3DA, and SLA surfaces; (d) cell morphology on the 3DA surface after culturing of bone marrow stromal cells (BMSCs) for 24 h observed using SEM. (Reproduced with permission from [167]. Copyright Elsevier, 2020).
Nanomaterials 10 01244 g006
Figure 7. (a) Schematics during laser engineered net shaping (LENSTM) and plasma-spraying treatments; (b) bond strength between HA and HA/LENS coatings and substrates; (c) accumulative Ag+ release in MgO-Ag2O-HA/Ti-6Al-4V and MgO-Ag2O-HA/LENS/Ti-6Al-4V group. (Reproduced with permission from [194]. Copyright Elsevier, 2019).
Figure 7. (a) Schematics during laser engineered net shaping (LENSTM) and plasma-spraying treatments; (b) bond strength between HA and HA/LENS coatings and substrates; (c) accumulative Ag+ release in MgO-Ag2O-HA/Ti-6Al-4V and MgO-Ag2O-HA/LENS/Ti-6Al-4V group. (Reproduced with permission from [194]. Copyright Elsevier, 2019).
Nanomaterials 10 01244 g007
Figure 8. (a) Schematics during anodization; (b) FESEM micrographs showing the morphology of the highly ordered TiO2 nanotubes present on NT-Ca/P; (c) high resolution XPS spectra of deconvoluted Ca 2p; (d) potentiodynamic polarization curves of Ti, NT, NT-Ca/P, and NT-RP-Ca/P samples immersed at 37 °C; (e) FESEM micrographs of MG-63 cells cultured on NT-RP-Ca/P surfaces after one day of incubation. (Reproduced with permission from [198]. Copyright Elsevier, 2016).
Figure 8. (a) Schematics during anodization; (b) FESEM micrographs showing the morphology of the highly ordered TiO2 nanotubes present on NT-Ca/P; (c) high resolution XPS spectra of deconvoluted Ca 2p; (d) potentiodynamic polarization curves of Ti, NT, NT-Ca/P, and NT-RP-Ca/P samples immersed at 37 °C; (e) FESEM micrographs of MG-63 cells cultured on NT-RP-Ca/P surfaces after one day of incubation. (Reproduced with permission from [198]. Copyright Elsevier, 2016).
Nanomaterials 10 01244 g008
Table 1. The important parameters for 3DP architectured implant preparation, in vivo studies.
Table 1. The important parameters for 3DP architectured implant preparation, in vivo studies.
3DP Material3DP MethodPore Size (μm) (a)Porosity (%)Pore ShapeAnimal ModelTime (b)ResultRef.
TiSLM300,
600,
900
61.6
66.4
64
diamond lattice with hexagonal pore throat shapeRabbit femur8WP600 implant is a suitable porous structure.[104]
Ti-6Al-4V (grade 5)EBM500–70065–70\Sheep
vertebra
26WA higher degree of osseointegration was observed inside the porous structure than in that of the dense group.[105]
Ti-6Al-4VSLM60070\Beagle tibia12WThe volume of regenerated bone increased with increase of the implantation time (from 11.89% at 4 weeks to 15.85% at
12 weeks), which was better than the Ta group.
[106]
Ti-6Al-4VEBM71068\Sheep vertebral6MTi cages demonstrated better osteointegration with surrounding bone tissue than PEEK cages.[107]
Ti-6Al-4VSLM900,
1200
84,
54
diamond latticeSheep
tibia
2M900 μm lattice cell size was more favorable to bone ingrowth.[108]
Ti-6Al-4VEBM45061.3\Domestic pig skull2MThe bone volume inside the implants reached almost 46%. BIC was achieved at 5.96%.[109]
Ti-6Al-4V3DP300–500,
200–600,
100–700
49.53\Bama mini pig tibia5WThe bone volume/total volume was 12.71–3.556%, 11.99–3.581%, and 12.84–3.874%, respectively.[110]
Ti-6Al-4VEBM\\\Rabbit femur2WThe implants with an EBM screw had a higher BIC ratio (≈35%) than those with the machine-implanted screw (≈5%).[111]
Ti-6Al-4VEBM500,
640,
800,
1000
65,
70,
67
diamond latticeRabbit distal femur12WPore size of 500–800 μm showed more favorable histological bone ingrowth than 1000 μm.[100]
Ti-6Al-4VSLM500,
600,
700
60,
70
octahedralRat Sprague-Dawley12WPore size of 500 μm and porosity of 60% had the highest BV/TV and hence the best bone ingrowth.[112]
(a) Pore sizes were presented as designed (measured). (b) W and M mean weeks and months.

Share and Cite

MDPI and ACS Style

Wang, Q.; Zhou, P.; Liu, S.; Attarilar, S.; Ma, R.L.-W.; Zhong, Y.; Wang, L. Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review. Nanomaterials 2020, 10, 1244. https://doi.org/10.3390/nano10061244

AMA Style

Wang Q, Zhou P, Liu S, Attarilar S, Ma RL-W, Zhong Y, Wang L. Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review. Nanomaterials. 2020; 10(6):1244. https://doi.org/10.3390/nano10061244

Chicago/Turabian Style

Wang, Qingge, Peng Zhou, Shifeng Liu, Shokouh Attarilar, Robin Lok-Wang Ma, Yinsheng Zhong, and Liqiang Wang. 2020. "Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review" Nanomaterials 10, no. 6: 1244. https://doi.org/10.3390/nano10061244

APA Style

Wang, Q., Zhou, P., Liu, S., Attarilar, S., Ma, R. L. -W., Zhong, Y., & Wang, L. (2020). Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review. Nanomaterials, 10(6), 1244. https://doi.org/10.3390/nano10061244

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop