1. Introduction
The technology that enables transmitting energy to an electric load wirelessly is known as Wireless Power Transfer (WPT) [
1]. WPT has found many applications in various scientific fields such as bioelectronics [
2,
3,
4] and the study of living animal behavior [
5]. Inductive WPT is an alternative to replace the tethering cable with power implants in the human body [
6]. WPT can also be a suitable alternative to existing traditional charging systems. For example, in bio-implants, rechargeable batteries with a smaller capacity, size, and more stability can be used instead of non-rechargeable batteries to reduce the number of surgeries for battery replacement [
7].
The inductive WPT system consists of three main parts. The first part consists of a pulse generator and a Power Amplifier (PA) that converts DC to AC power and delivers it to the power transmission coil on the primary side. The second part is called the induction link, which is composed of two coils for power transmission, as well as magnetic coupling between them. Typically, there are two coils in the second part of the inductive WPT technique: Implanted and external coils. The implanted coil often has a small size and is placed in the body to receive power from an external coil. Finally, the third part is an AC-to-DC converter (rectifier) that delivers the AC power received from the induction link as DC power to the system load [
8,
9].
Power transmission uniformity is necessary to avoid interruption of the moving load during its operation [
10]. Thus, the moving internal coil (as load) requires a free positioning area wherein it can move freely and receive the required power. In free-moving applications, there are two methods to deliver power to a moving target: First, using a single transmitter coil that is big enough to cover the moving internal coil route [
5]; second, using a transmitter array [
11]. Using a big coil is not a solution to creating uniform fields in the moving internal coil (receiver). The resultant field distribution is strong at the coil center and drops at the borders [
12]. Therefore, the technique is not reasonably efficient. The second idea, i.e., using array coils, has the advantage of higher Power Transfer Efficiency (PTE); it can also track the receiver coil position so as to deliver power, particularly to the coil at the position with optimal PTE [
13]. However, the presence of black spots causes a non-uniform electromagnetic field in the coil array. The interaction of the vector fields in the neighboring borders of the two adjacent transmitter coils causes the minimization of the resultant fields at these points. Therefore, the power delivered to the moving object decreases dramatically at these points. These points are defined as power blank spots. Extending the charge time or disconnecting the charging is the result of power transmission non-uniformity and blank spots [
14].
Figure 1 shows the schematic of the moving load, which is extensively used in biomedical applications ranging from capsule endoscopy [
15] to optogenetics [
16]. A big single coil with a moving coil shown in
Figure 1a causes misalignment between the external and moving internal coils. Moreover, the Gaussian distribution of this field creates blank spots at bigger coil borders. It can significantly impact both the charging efficiency and time. Therefore, by using smaller-sized external array coils, the Gaussian field distribution is broken into several Gaussian fields and creates a more uniform field distribution. The multi-coils shown in
Figure 1b are in the form of an array to create a uniform field for the application of free-moving objects, as discussed earlier.
Extensive research has been performed to study inductive WPT devices with three, four [
17], and even more external coils [
18]. Different topologies in array structures have been able to cover a large area, and various methods have been proposed for power transmission uniformity and the elimination of blank spots [
19,
20]. The most important ideas in the literature concern proposing models for the electrical excitement of external coils via a power supply [
21]. Although these methods are effective in eliminating blank spots, the uniformity of the power transmission still remains a major challenge. In addition, by tracking the internal coil, only the neighboring external arrays can be turned on, and this increases the PTE and reduces power consumption. The tracking mechanism of internal coils has received less attention from researchers.
In this paper, we design and characterize a transmitter array composed of eight coils that are excited separately as an inductive WPT source for a moving coil. These eight coils are placed on top of each other in two layers with 50% overlap. We show the superior performance of the structure over other solutions to achieve uniformity of power transmission. Eliminating black spots and creating a uniform field for the application of a free-moving object while maintaining high efficiency is the main achievement of this research.
Optimal coils and links are designed using theoretical equations in
Section 2 based on the circuit model of the inductive link. Then the array structure for these designed coils in free-moving objects is used. The field distributions of overlapped and non-overlapped array structures are compared over the movement direction of the internal coil in
Section 3. Furthermore, a tracking mechanism based on feedback is applied for moving objects to increase the efficiency of the system. The simulations and measurement results of fabricated circuits and systems are compared and demonstrated in
Section 4 via theoretical analysis. The conclusions drawn about the overlapping array are presented in
Section 5.
2. Theoretical Model of Inductive Power Transmission
Figure 2a presents the three main parts of an inductive power transmission system. It consists of an oscillator controlled by a Microcontroller Unite (MCU), power amplifier, inductive link, rectifier, and load [
22,
23,
24]. Optimization of the induction link requires making several trade-offs on the size aspect ratio, the distance between coils, and the coordinating misalignment between coils. Key elements of this optimization are coil parameters including size, width, and quality factors, as well as inductive link factors such as using intermediate resonator coils, connecting the external coil configuration, and reducing misalignment techniques [
25]. To obtain a better view of efficiency optimization, the circuit model of the link is observed. For inductive WPT applications where the coil size is much smaller than the wavelength of the fields, distributed-element models are not required. Therefore, the induction coil is modeled according to
Figure 2b. Parasitic and other elements in this model are derived from PCB coils. In this model, inductance (
Ls) indicates the ability of the coil to store electromagnetic energy and is obtained by Equation (1) [
26].
where
a is the average internal and external radius,
b is the height,
c is the thickness of the coil along the radius, and n is the number of revolutions per layer. The intrinsic parallel capacitor (
Cp) is determined by the spacing between planar conductive traces and their surrounding materials. PCBs are implemented on organic, ceramic, or silicon substrates and coated by an insulator, such as Perylene or silicone. In bioelectronic applications, coils are surrounded by tissue and fluids that have high permittivity. This causes an increase in the parasitic capacitance of the PSCs compared to when coils are in free air. The intrinsic parallel capacitor can be expressed by Equation (2) [
27].
where
lc is the PCB conductor length and
C’ext is the capacity per-unit length obtained for the PCB coil and the surrounding materials such as tissues, the PCB substrate, the PCB coating, and air. The frequency at which the inductance (
Ls) and intrinsic parallel capacitor (
Cp) cause resonance is called the Self-Resonant Frequency (
SRF) and is found by:
In inductive design, the SRF frequency is usually higher than the ISM band (Industrial, Scientific, and Medical band), and to avoid interference, the resonance frequency of the circuit must be much smaller or equal to SRF [
28,
29]. The series resistance (R
S) is a model of the losses that occur in the conductor of the coil. The skin and proximity effect at higher frequencies cause the conductor resistance and losses to increase with frequency. The skin effect increases the AC resistance of the coil at high frequencies [
27]. At a frequency of zero, a uniform current density flows through the conductor, but as the frequency increases, the current density is large near the surface of the conductor and decreases exponentially with greater depths in the conductor. The current flows mostly in the skin of the conductor. The skin is the outer surface of the conductor and its depth, which depends on the current frequency. In other words, as the frequency increases, the effective current decreases and the conductor resistances increase [
30]. The series resistance
RS is calculated by applying Lenz’s law and considering the Eddy Current according to Equation (4).
where
t0 and w are the conductor thickness and width, respectively.
RDC is the zero-frequency conductor resistor,
δ denotes the skin thickness, and
ωcrit is the critical frequency of the proximity effect. The parallel resistor (
Rp) models the loss of dielectric layers occurring at the power transmission site. Dielectric losses can be described by the loss tangent of each material’s tan (
δ), which is related to its conductivity
.
are the permeability of the free space and material, respectively.
Rp is the sum of material conductivity in the multilayer material such as in
Figure 2d. In the model introduced in
Figure 2b, the quality factor (
Q) of a coil defines the ratio of energy stored to energy lost. To achieve a high-quality factor coil, the R
S must be kept as low as possible.
Considering the quality coefficient as a result of the series resistance (
QS) and the quality coefficient as a result of the parallel resistance (
QP), the total quality coefficient can be calculated by Equation (5) [
31].
In the induction link, the external coil produces a time-variant magnetic flux. Part of this flux passes through the space occupied by the internal coil and generates the voltage according to Faraday’s first law. Mutual Inductance (
M) represents the ratio of the flux passing through the internal coil to the excitation current of the external coil. Mutual Inductance for the two coils with one wire loop can be calculated by Equation (6) [
28]. Note that for coils with a high number of turns (i.e.,
n > 1), the sum of the
M values at each turn must be calculated.
where
μ0 is the vacuum permeability and
a and
b are the coils’ radius. Furthermore,
z is the coil spacing parameter. According to [
28], the induction link voltage gain PTE is calculated by Equation (7).
where
K is the coupling factor,
n is the number of coil turns, and
Q1 and
Q2 are quality factors due to the external and internal coils, respectively. In Equation (7),
α is a dimensionless parameter and depends on
Cp as well as the load resistance. To obtain the maximum power transfer, we extract the alpha value for which Equation (7) is maximized. Therefore, to gain the maximum efficiency, the term
K.
Q1.
Q2 must reach the maximum value [
28]. The coupling factor is related to the mutual inductance by
M =
K sqrt (
L1L2). Thus, provided that
L1 and
L2 remain unchanged,
K reaches the maximum when
M takes its highest value. As mentioned in Equation (6),
M is dependent on the coil geometry. A crucial parameter of the
M value is the distance between two coils, which reduces the
M proportional to 1/
z2. With regard to
Q1 and
Q2, a key factor in their values is the parasitic resistance
Rs and p of both coils in the link, which should be kept as low as possible to preserve high
Q as shown in Equation (5). To obtain a low
RS, according to Equation (4), the wire thickness (c) with respect to the width (b) must remain low. With all these considerations, the coils with high-efficiency power transfer are designed in
Section 3.2.
4. Results and Discussion
The two proposed overlapped array coils in the inductive WPT system are shown in
Figure 6a. The microcontroller excites each external coil by the PA. The internal coil receives power from one of the external coils and transfers it to the rectifier. The rectifier converts the received signal from the internal coil to DC power and transmits it to the load. The two-layer PCB (double-sided PCB) is fabricated for the transmitted circuit as shown in
Figure 6b. As can be seen, the main area of the PCB is dedicated to the NMOS Switch parts. Moreover, other parts of the transmitter circuit including the PA, gate drivers, gain, filters, and microcontroller are marked. The transmitter circuit is connected to the transmitter-tuned array via blue terminals on top of the PCB board. Furthermore, the micrograph of the PCB is shown in
Figure 6b. The transmitter circuit area is 7.5 × 16 cm.
The voltage and current of fabricated circuits are recorded to measure the PTE of the inductive WPT system. The fabricated system shown in
Figure 6b was connected to the designed external coil array (
Figure 4a). The internal coil was connected to the ohmic load via a rectifier. The signal waveforms of the circuit were measured and examined using an oscilloscope.
The waveform voltage was measured at different nodes to investigate the performance operation of the circuit by a digital oscilloscope (GW Instek GDS-3000).
Figure 7a indicates the PA voltages. The blue line shows the input voltage waveform of PA in the presence of an 82 Ω load in the receiver coil. The orange line shows the eight-volt voltage regulator (V
DD). The RMS input current of the circuit was measured to be approximately 80 mA. The input of the PA is a pulse with an amplitude of approximately 10 V from peak to peak. To evaluate the performance of the output rectifier, the voltage waveform was measured at the input and output nodes of the rectifier.
Figure 7b,c shows the input and output voltage of the rectifier in the no-load mode and with a load of 82 Ω. The blue line shows the input signal sent to the rectifier and the orange line shows the DC voltage delivered to the load. In the presence of an 82 Ω load, the output voltage was measured at approximately 6 V. The output current was recorded in the presence of 73 mA. By calculating the power at the regulator output and load input, an efficiency of 68% was obtained for the proposed inductive WPT.
Figure 8 shows the electromagnetic field distribution and power transfer efficiency for both overlapped and non-overlapped structures. Simulation is verified by the Ansys HFSS 3D electromagnetic (EM) simulator at the working frequency (900 kHz). The moving internal coil moves at a distance of Z = 4 cm above the external array coils. Based on the top plot of
Figure 8a, the electromagnetic field for moving the internal coil at blank spots (such as the X1 point) is cyan, which is in the range of 39–43 dB according to the color bar. Meanwhile, in the top plot of
Figure 8b, it increased to lawn green color showing a range of 55–59 dB at both blank and other spots and maintained uniformity of the field distribution. Furthermore, PTE distributions are shown for overlapped and non-overlapped structures in
Figure 8. As shown in the bottom plot of
Figure 8a, the power measurement for non-overlapped structure variation is approximately 50% on top of the first external coil to the blank spot (X1) while the internal coil moves along the
x-direction. When the internal coil starts to move, the internal and external coils are not necessarily co-axial. The coupling factor decreases when the receiver coil moves away from the center of the transmitter coil. Decreasing the coupling factor affects the system performance in three ways: (1) Load matching conditions are disruptive, (2) the link voltage gain changes, and (3) the load seen from the initial side of inductive WPT changes and reduces the efficiency of PA and changes the voltage of the coil.
PTE for the overlapped structure is measured in the bottom plot of
Figure 8b with more uniform PTE distribution variations of approximately 10% along the
x-axis. This change led to a uniform distribution of the electromagnetic field at the junction of the coils. This helps deliver constant power to the internal coil along the entire
x-axis.
The effect of height changes in the range of 30 to 60 mm on the received power as well as the efficiency of the system was investigated. As shown in
Figure 9, by increasing the distance between the internal and external coils, the delivered power and, consequently, the circuit efficiency decrease linearly. As depicted in
Figure 9, point X was equal to 25 mm (X = X1 = 25 mm, the boundary between two coils on the first plate, see
Figure 4). Changing the height of the moving coil in the overlapped configuration leads to a change in the received power, but as shown in the PTE distribution in
Figure 8b, it does not disturb the uniform electromagnetic field in the
x-direction.
To evaluate the coding mechanism for tracking a moving object (internal coil), a test based on the movement of the coil was performed. In this test, the field distribution with internal coil movement from the top of the first external coil (X
p1) to the next coil (X
p2) was tracked as shown in
Figure 10. The field intensity at each point indicates which external coil(s) is excited. This excited zone is shifted by the movement of the internal coil. As is shown in
Figure 10, by changing the position of the internal coil from X
p1 to X
p2, only the external coils in the moving object’s neighborhood are excited. Therefore, they are coupled to the internal coil and the current flow in it. Furthermore, other external coils are in sleep mode. This mechanism helps to preserve some power consumption.
Furthermore, the power-saving mechanism does not affect the uniformity of the field distribution as depicted in
Figure 10a–c. Even in the blank spot positions for the internal coil (X1) shown in
Figure 10b, 68–72 dB was recorded for field distributions, the same as in X
p1 and X
p2.
Specific Absorption Rate (SAR) simulation results for biostability are shown in
Figure 11. The simulation employed the ANSYS HFSS
TM human model at 900 kHz (ISM band), for 1 W of input power. The SAR obtained at the working frequency, 0.115 mW/kg, is lower than the IEEE standard of 2 W/kg for 10 g of tissue [
32].
Table 2 shows the main specifications of the proposed system. Moreover, this table provides the specifications of similar systems reported in the literature. It is clear that the power delivered to the load (PDL) as well as the power efficiency in this research is very significant. Meanwhile, the uniform electromagnetic field distribution and the removal of black spots were obtained in the present study. It should be noted that reducing the size of the coil decreases the system’s efficiency. Coils with smaller sizes can operate and deliver lower power because the smaller coil is exposed to fewer lines of the electromagnetic field. For internal coils with dimensions of 10 × 10 cm, the delivered power and efficiency were recorded as 266 mW and 41%, respectively.
Table 2 summarizes the performance of the WPT system compared with the state of the art using the FOM introduced in [
33], which uses the following parameters: The separation distance between the external and internal coils (d); the size of the external excitation coil array; the size of the internal coil; and the PDL and the PTE of the system. As shown in
Table 2, the performance of the presented system is among the best-reported results. Using non-overlapped and overlapped coils in this system improves the PTE uniformity and illuminates blank spots. Furthermore, the tracking feedback mechanism improves PTE.
With the increasing use and tendency of wireless applications, the need to create a uniform field along the path of the moving receiver is increased. For free-moving transmitter coil applications, especially in biomedical or other applications such as electric vehicles, having a uniform field distribution among all the variations in the target position with respect to transmitter coils is a challenge.
In this research, we proposed a uniform field distribution for a moving object by using an overlapped-coils array. We presented a tracking mechanism to reduce the power consumption by avoiding all external coils’ excitation simultaneously. This tracking is performed using feedback from the moving coil position. Moreover, to remove the blank spots created by array coil borders and the field’s non-uniformity, overlapping mechanics are proposed.
For further investigation of this research, designing a high-efficiency link using a high-quality coil design and adding a matching circuit for the internal coil are suggested. Moreover, it is expected that by expanding the array into two or three dimensions, the proposed WPT system becomes more practical. Furthermore, by using the optimal positioning technique with the MCU algorithm or using the camera, the system speed and efficiency will increase.