1. Introduction
Irbesartan, (IUPAC name: 2-butyl-3-({4-[2-(2H-1,2,3,4-tetrazol-5-yl)phenyl]phenyl} methyl)-1,3-diazaspiro [4.4]non-1-en-4-one, see
Figure 1), is a potent and selective angiotensin II receptor antagonist recommended for use in patients with hypertension and those with type 2 diabetes mellitus and nephropathy [
1,
2].
The EU has classified many drugs, including sartans, as “emerging pollutants,” substances whose effects on the environment and the human population in the short and the long term have not been thoroughly studied yet. In the EU, drugs come into contact with the environment through wastewater and sewage sludge, while production plants are secondary sources [
3,
4,
5,
6].
In the last decades, drug treatment has sharply increased, especially among the older population, and Losartan and Irbesartan are among the most prescribed antihypertensive medicines [
7,
8,
9]. They can pose a more significant threat than other substances because, as drugs, they are designed to be effective at low concentrations and because they are left unscathed by wastewater treatment plants [
10], making their removal and monitoring of the utmost importance.
High-Performance Liquid Chromatography (HPLC), coupled with a UV detector or MS/MS spectrometry, is the primary analytical technique used to investigate sartans in drug formulations or biological and environmental samples [
11,
12,
13,
14,
15]. These techniques are time-consuming, can be expensive, often require a large quantity of solvents, and are not suitable for in situ analysis. Ultra-Performance Liquid Chromatography (UPLC) has been proposed as an alternative to HPLC because of the lesser volumes of solvents needed [
11].
Electrochemical methods have rarely been investigated, using mainly Hanging Drop Mercury Electrode (HDME). For example, Gupta et al. [
16] developed a voltammetric method for determining Irbesartan in pharmaceutical formulations. By applying Differential-Pulse Voltammetry (DPV), a cathodic peak appeared at −1.4 V (vs. saturated calomel electrode, SCE), corresponding to the reduction of the C=N double bond of the tetrazolyl moiety. A similar method was also proposed for determining Irbesartan in pharmaceuticals and biological fluids [
17] by using both Differential-Pulse Voltammetry (DPV) and Square-Wave Voltammetry (SWV), obtaining a detection limit of about 0.7 µM. A more sensitive voltammetric determination was that reported by El-Desoky et al. [
18] for dosing Irbesartan in human blood and pharmaceutical formulations; a very low detection limit, 2 nM, was achieved by applying square-wave adsorptive cathodic stripping voltammetry.
For years, mercury electrodes have been the leading choice for voltammetric measurements. However, in the last decades, environmental and safety concerns have restricted their application and encouraged the exploration of more eco-friendly materials less toxic than mercury, with more possibilities for flow and in-situ analysis [
19]. In this scenario, screen-printed electrodes (SPEs) had significant growth in demand since the screen-printing technique offers advantages in terms of versatility, cost-effectiveness and ease of use [
20]. Moreover, screen-printed electrodes are among the most suitable sensors for in situ analysis thanks to their low power needs, rapid response, and good sensitivity [
21]. The excellent versatility of the SPEs is driven primarily by the numerous ways in which the electrodes can be modified. For example, the composition of the inks may be changed by adding different substances, such as complexing ligands, metal particles, polymers, or enzymes. Otherwise, modifying the manufactured electrodes by depositing on their surface metal films, nanoparticles, biological material, and polymeric films is possible [
22].
Molecularly imprinted polymers (MIPs) have been employed in various analytical methods, including electrode surface modification for potentiometric or voltammetric measurements to improve selectivity; a gain in sensitivity was also verified several times [
23]. MIP-based sensors are some of the most popular approaches for detecting different classes of analytes, primarily biological molecules. MIPs embody a class of synthetic receptors that mimic natural antibody–antigen interactions, i.e., the “lock and key” mechanism to bind the target analyte selectively [
24]. For MIP synthesis, monomers are polymerized in the presence of a target molecule (the so-termed template), which is removed after the polymeric network is formed. The template removal leaves cavities in the polymers that mirror the target molecule’s shape [
25].
In this view, they possess the high selectivity and specificity of biological receptors but with the added advantage of being artificial polymers, much more stable and readily adaptable for the modification of electrode surfaces [
26].
The development of MIPs tailored to screen-printed electrodes has accelerated the shift from bulky conventional techniques to low-cost and rapid-sensing devices for in-field analyses [
27]. Recently, several studies have been published regarding the development of MIP-based screen-printed electrodes for both the voltammetric and potentiometric sensing of environmental contaminants, emerging pollutants, or biomolecules [
28,
29,
30,
31,
32,
33,
34,
35,
36,
37,
38,
39,
40].
Following this trend, a MIP-modified screen-printed carbon electrode for Irbesartan voltammetric sensing is developed. The MIP’s prepolimeric composition and the experimental parameters for the analysis by Square-Wave Voltammetry (SWV) are optimized using a Design of Experiments (DoE) approach. The reliability of the proposed method is proved by the analyses of tap water samples fortified with the drug.
2. Materials and Methods
2.1. Reagents and Instruments
Methacrylic acid (MMA) and ethylene glycol dimethacrylate (EGDMA) were purchased from Merk Life Science S.r.l. (Milano, Italy) and filtered with an aluminum oxide column to remove stabilizers.
Moreover, 2,2-azobisisobutyronitrile (AIBN), glacial acetic acid ≥ 99%, methanol, sodium acetate trihydrate, Irbesartan, and Losartan were used as obtained from Merk Life Science S.r.l. (Milano, Italy). Solutions for the electrode surface characterization were prepared using sodium chloride, potassium chloride, and potassium hexacyanoferrate (III) (Merk Life Science S.r.l., Milano, Italy). Three-electrode screen-printed cells with a graphite-ink working electrode, Ag/AgCl-ink pseudo-reference electrode, and a graphite-ink counter electrode were produced by Topflight Italia SPA (Vidigulfo, Pavia-Italy). Tap water from the lab sink (Department of Chemistry, University of Pavia, Italy) was used to prepare fortified samples.
Voltammetric analyses and impedance spectroscopy measurements were performed by the potentiostat/galvanostat EmStat4s-PalmSens BV (Houten-The Netherlands). The pH of buffers and solutions was checked by a pH-meter Mettler Toledo mod. SevenMulti, equipped with a combined glass electrode InLab Pro (Mettler Toledo, Milan, Italy).
2.2. Prepolymeric Mixture and Modification of the Working Electrode Surface
The prepolymeric solution was prepared according to the optimized procedure by mixing Irbesartan (IRB), MMA, and EGDMA with a molar ratio of 1:4:10 and adding the minimum amount of methanol to facilitate and completely dissolve all components. The mixture was deaerated with a gentle flow of N2 for 5 min; then AIBN was included, and the mixture was sonicated until obtaining a limpid solution.
An equal prepolymeric mixture not containing Irbesartan was prepared for functionalizing the working electrode with the NIP (non-imprinted polymer).
Each screen-printed cell (SPC) was washed with methanol and left to dry at room temperature under a hood. A small volume of the prepolymeric mixture (3 µL MIP or NIP mixture) was drop-coated on the cleaned surface of the working electrode. The thermal polymerization was carried out in a thermostatic oven at 60 °C overnight.
The SPC was then subjected to 7 cleaning cycles by immersion for 1 h in 10 mL of a mixture of glacial acetic acid ≥ 99%/methanol = 1/4 to remove the template (IRB) and unreacted monomers. The so-cleaned functionalized SPC was stored at room temperature and hydrated in ultrapure water for 10 min before use.
2.3. Characterization of the Working Electrode Surface
The electrochemically active area was measured before and after the working graphite electrode surface modification with MIP or NIP.
It was determined by cyclic voltammetry (CV) in 5 mM K4Fe(CN)6/0.1 M KCl solution at pH 7.2 as an electrochemical probe (Estart = −1 V, Eend = +1 V, scan rate 0.025 ÷ 0.5 V/s).
The square root of the scan rate vs. the intensity of the anodic or cathodic peak was plotted; from the slope (
K), the effective area is obtained through the modified Randles–Sevick’s equation [
35,
41]:
D and C are, respectively, the diffusion coefficient (D = 3.0910−6 cm2/s) and the concentration (C = 5 mM) of the electrochemical probe K4Fe(CN)6; n is the number of the electrons acquired for the reduction of the electrochemical probe, i.e., n = 1 according to the reaction: Fe(CN)63−+ e− → Fe(CN)64−.
The Electrochemical Impedance Spectroscopy (EIS) experiments were carried out in 15 mL of 5 mM K4Fe(CN)6/0.1 M KCl solution at pH 7.2 (electrochemical probe solution), registering the electrochemical impedance from 100 kHz to 10 mHz, and a signal amplitude of 50 mV. The analyses were performed for unmodified screen-printed cells (bare) as well as for those modified with MIP and NIP.
2.4. Irbesartan Determination by Square-Wave Voltammetry (SWV)
Irbesartan was detected by Square-Wave Voltammetry (SWV) in 15 mL of 0.1 M acetate buffer solutions at pH 5.5, gently stirring and applying the experimental conditions, optimized through a Design of Experiments (DoE) approach, as reported in
Table 1.
3. Results
3.1. Screen-Printed Working Electrode Functionalization
When using screen-printed cells, the first concern is the modification only of the working electrode surface, avoiding the possible compromise of the counter and pseudo-reference electrodes. Therefore, a good option was a drop-coating of a small volume of the prepolymeric mixture. After testing volumes from 1 to 5 µL, the correct quantity was determined to be 3 µL, enough to coat the working electrode surface and leave the other electrodes unaltered.
The second step was the optimization of the prepolymeric mixture composition aiming to obtain the best compromise in terms of sensitivity and selectivity; thus, a simple full factorial design 2
3 was applied.
Table 2 summarizes the parameters under investigation and the corresponding minimum and maximum levels. The current peak (
ip, µA) obtained by SWV analysis was evaluated as the response. The data were processed using the open-source software CAT (Chemometric Agile Tool) [
42]. The graph of
Figure 2 shows the significance of the model’s coefficients.
The model equation can be written as follows:
The values of the coefficient and their significance are summarized in
Table 3.
The coefficient plot of
Figure 1 highlights that the significant parameters/interactions are the mmol of EGDMA and the interaction between mmol MAA and mmol EGDMA; conversely, the solvent volume is irrelevant. The mmol of EGMA has a negative effect on the current peak, so it has to be set at the minimum value (−1 = 0.5 mmol). The interaction between mmol MAA and mmol EGDMA presents a significant negative effect on the response; thus, setting mmol EGDMA at the minimum value (−1 = 0.5 mmol), mmol MAA has to be set at the highest value (+1 = 0.2 mmol).
Six replicates at the center point [0 0 0] were set up, and the average value, standard deviation, and confidence interval (CI) at a 95% confidence level are reported in
Table 4. The predicted value fits into the confidence interval; thus, the model is validated.
Therefore, the optimal prepolymeric mixture had the following composition:
IRB: MAA: EGDMA = 0.05 mmol:0.2 mmol:0.5 mmol = 1:4:10. As previously stated, the volume of methanol is irrelevant, and the maximum value of 0.8 mL was selected to be sure to solubilize all the mixture components well.
3.2. Characterization of the Working Electrode Surface
3.2.1. Electrodic Active Area
The electrodic area was calculated for the bare, MIP-, and NIP-modified electrodes. Each obtained value was compared to the theoretical one. In order to define the active area, cyclic voltammetric measurements were performed in an electrochemical probe solution at different scan rates, and the reduction or oxidation peak height was plotted against the square root of the scan rate. The slope of the obtained straight line (
K) was entered in Randles–Sevick’s equation (Equation (1),
Section 2.3) to obtain the active area’s value.
Since both reduction and oxidation peaks were analyzed,
Table 5 shows the averages of the two area values.
The values in
Table 5 show that the active area decreases when the electrode is coated with a non-conductive polymer. As we expected, the active area of the MIP-modified electrode is higher than that of the NIP-modified electrode; this behavior is due to the cavities in the molecularly imprinted polymer, which are, on the contrary, absent in the NIP.
3.2.2. Electrochemical Impedance Spectroscopy (EIS)
Electrochemical Impedance Spectroscopy is a technique used to characterize the electrodic surface; in particular, the polymers’ non-conductive nature may be verified. The measurements were performed in 15 mL of 5 mM K
4Fe(CN)
6/0.1 M KCl solution. The NIP-modified electrode, the MIP-modified electrode after the template removal, and the sane electrode recharged with the analyte were analyzed.
Figure 3 shows the Nyquist plots obtained for each electrode.
As can be observed from the Nyquist plot, the resistance of the electrode surface increases passing from the washed to the recharged polymer that modifies the screen-printed cell. This behavior may be related to the presence of the analyte that plugs the pores and prevents the electric charges from reaching the electrode surface. This behavior is amplified using the NIP, which has a lower porosity than the MIP.
The Nyquist plot may be explained as recurring to a Randles’ equivalent circuit describing the obtained trends, reported in
Figure 4.
The Randles equivalent circuit of
Figure 4 comprises three different circuital elements. R1 is the resistance of the solution, R2 is the resistance to the charge transfer of the electrode/electrolyte interface, and W is the Warburg component that describes the diffusive processes, while Q1 represents the constant phase element. Q1 (or constant phase element, CPE) describes the accumulation of ions on an inhomogeneous electrode surface, and it is used instead of the classic C
dl (double-layer capacitance).
The fitting curves in
Figure 3 were calculated according to Randles’s equivalent circuit over-described. The Nyquist plots with their fitting for each electrode are shown in the
Supplementary Materials.
The fitting error was obtained using the following Equation (3) [
43]:
fit stands for fitting value,
exp for experimental value, and N for the number of points taken into account. The calculated fitting errors are reported in
Table 6.
3.3. Irbesartan Determination by Square-Wave Voltammetry (SWV): Optimization of the Procedure, Calibration and Real Sample Analysis
Once the screen-printed cell (SPC) was modified with the molecularly imprinted polymer, and before its use for the voltammetric measurements, it was washed several times with a mixture of methanol/glacial acetic acid ≥ 99% = 1/4 to remove the template molecule. Calibration measurements were performed on both the bare electrode and the MIP-modified one. The experiments were carried out in 30 mL of 0.1 M acetate buffer at pH 5.5 and applying SWV; the signal was recorded after an equilibration time of 120 or 300 s, respectively, for the bare electrode or the MIP-/NIP-modified one. For the MIP-modified electrodes, the equilibration time corresponds to the incubation period necessary for the Irbesartan molecule to reach the cavities of the polymeric film. The experimental conditions for both electrodes were optimized by a full factorial design 2
3; the current peak (
ip, µA) was evaluated as the response. The levels of the variables, the coefficient plots, and their significance and model equations are reported in the
Supplementary Materials.
Table 1 (
Section 2.4) shows the optimized SWV experimental conditions for bare and MIP-/NIP-modified electrodes.
Figure 5 shows the calibrations obtained for the electrodes modified with MIP and NIP by plotting the cathodic current peak (
ip, µA) vs. Irbersartan concentration (µM). As expected from the experiments performed with the NIP-modified electrode, only a residual current independent of the Irbesartan concentration was registered.
The straight line’s equations of the calibrations reported in
Figure 5 are:
ip [µA] = 1.30(3) + 6.9(2)∙[IRB, µM] R2 = 0.994 for the MIP-modified electrode;
ip [µA] = 1.23(3) − 0.4(3)∙[IRB, µM] R2 = 0.168 for the NIP-modified electrode
(number in round brackets is the standard deviation of the last digit).
Experimental conditions: SWV in 0.1 M acetate buffer pH 5.5; Estart: +1 V; Eend: −1.5 V; frequency: 1 Hz; amplitude: 0.05 V; equilibration time: 300 s. The error bars correspond to the standard deviation of the measurements performed with three electrodes.
The detection and quantification limits were calculated by the following Equations (4) and (5):
where
sy/x is the standard deviation of
y-residuals (i.e., the random errors in the y-direction); this value can be assumed not significantly different from the standard deviation of replicate measurements of blank solutions [
44].
For the MIP-modified electrodes, the values expressed as the average of the results obtained from three different calibration curves using three screen-printed cells were LOD 0.012(3) μM and LOQ 0.03(1) μM.
Some calibrations were also performed with the bare screen-printed electrode applying the optimized operative conditions reported in
Table 1. In this case, the linearity range was slightly wider than that achieved with the MIP-modified electrode, but higher LOD and LOQ were obtained.
Table 7 summarizes the analytical performances for both modified and non-modified electrodes.
The applicability of the MIP-based screen-printed electrode for environmental analyses was tested by using it to detect Irbesartan in fortified tap water samples.
Table 8 shows the recovery% and error% obtained; they were calculated by Equations (6) and (7), respectively.
Table 8 shows good recoveries and a maximum error of 7.1% for the MIP-modified electrode, while the bare one is definitely not a selective sensor since the recoveries were unsatisfactory. The bad results obtained with the bare electrode could be due to the interference of electroactive substances present in the real samples; the presence of the specific MIP’s cavities reduces the chance of such interferents reaching the electrode surface, making more accurate measurements possible.
In
Table 9, the analytical performances of the MIP-based screen-printed electrode are compared with those of other electrochemical methods for sartan detection reported in the literature.
3.4. Interference Test
The selectivity of the MIP-modified electrode was tested in solutions containing Losartan (see the molecular structure in
Figure 6).
As can be observed from
Figure 1 and
Figure 5, the molecular structures of Irbesartan and Losartan are very similar; for this reason, the comparable behavior of the MIP-modified electrode for both analytes can be expected. SWV performed the calibration measurements in the same conditions described for the Irbesartan experiments. As an example, the equation of the straight line obtained from a calibration curve with an MIP-modified electrode in Losartan solutions is reported below:
The sensitivity of the sensor for 1.4 µA/µM of Lorsartan is five times lower than that obtained for Irbesartan, but is still significant; therefore, effectively, the electrode also allows the dosage of this molecule. The fact that the sensor responds non-specifically but selectively to sartans of a similar structure may be advantageous for application in the analysis of environmental samples contaminated by a mixture of these substances.
4. Conclusions
This paper describes a screen-printed voltammetric sensor for the determination of Irbesartan, obtained by modifying the graphite working electrode surface with a molecularly imprinted polymer (MIP).
Before and after modification, the working electrode surface was characterized by EIS and the active area was calculated. The results of both methods demonstrated the covering of the surface with the MIP layer.
From the calibration measurements performed under optimized conditions, a LOD of 0.012(3) μM and a LOQ of 0.04(1) μM were obtained.
The applicability of the sensor for environmental analyses was tested by detecting Irbesartan in fortified tap water samples obtaining good recoveries.
Selectivity tests were also undertaken using Losartan as an interferent. The sensor’s sensitivity for this sartan was five times lower than that obtained for Irbesartan, but was still significant. It can then be concluded that the MIP-modified electrode responds non-specifically but selectively to sartans of similar structures. This experimental evidence was predictable given the very similar structure of the two compounds but can be considered advantageous for applying the sensor in the analyses of environmental samples containing a mixture of these emerging contaminants.