Investigation and Computational Modelling of Variable TEG Leg Geometries

1
Heat Pipe and Thermal Management Research Group, College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, London UB8 3PH, UK
2
Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50370 Wroclaw, Poland
*
Author to whom correspondence should be addressed.
ChemEngineering 2021, 5(3), 45; https://doi.org/10.3390/chemengineering5030045
Submission received: 31 May 2021 / Revised: 21 July 2021 / Accepted: 30 July 2021 / Published: 4 August 2021
(This article belongs to the Special Issue Advanced Heat Exchangers for Waste Heat Recovery Applications)

Abstract

:
In this work, computational modelling and performance assessment of several different types of variable thermoelectric legs have been performed under steady-state conditions and the results reviewed. The study conducted has covered geometries, not previously analysed in the literature, such as Cone-leg and Diamond-leg, based on the corresponding thermoelectric generator leg shape structure. According to the findings, it has been demonstrated that the inclusion of a variable cross-section can have an impact on the efficiency of a thermoelectric generator. It has been concluded that the Diamond configuration generated a slightly larger voltage difference than the conventional Rectangular geometry. In addition, for two cases, Rectangular and Diamond configurations, the voltage generated by a TEG module consisting of 128 pairs of legs was analysed. As thermal stress analysis is an important factor in the selection of TEG leg geometries, it was observed based on simulations that the newly implemented Diamond-leg geometry encountered lower thermal stresses than the traditional Rectangular model, while the Cone-shape may fail structurally before the other TEG models. The proposed methodology, taking into account the results of the simulation carried out, provides guidance for the development of thermoelectric modules with different forms of variable leg geometry.

Highlights

New TEG leg geometries (Cone-leg and Diamond-leg) were provided and studied.
Temperature distributions, voltage potential and thermal stress analyses in COMSOL were carried out.
Electrical analysis for TEG modules consisting of 128 pairs of legs was conducted.

1. Introduction

Energy consumption is increasing year by year. Due to the EU’s Energy Union strategy introduced to improve energy efficiency and sustainability, as detailed by J. Malinauskaite et al. [1], researchers are looking for different solutions to recover waste heat energy [2,3,4,5]. In both industrial and non-industrial sectors, the use of thermoelectric generators (TEGs) is perfectly in line with this trend. TEGs are amongst the most promising solid-state energy generators. TEG modules directly transform thermal energy into electricity, employing the commonly known Seebeck effect when working between two thermal reservoirs [6]. They have no moveable materials; they are compact; they are noise-free; and they are suited quite well for solar energy and waste heat conversion to electricity using car exhausts [7], stoves and PV panels. The phenomena occurring in TEG and possible applications have been extensively discussed by H. Jouhara et al. in [8].
In some applications, heat exchangers are additionally used to increase the heat exchange surface area and thus improve the thermal performance of the TEG. As noted by H. M. Maghrabie et al. in [9], heat transfer intensification can take different forms. However, S. Soleimani and S. Eckelsb [10] drew attention to the relationship between the increase in convective heat transfer surface area and the fluid flow drag then occurring.
It is understood that thermoelectric element (TE) modules are comparatively inefficient. Therefore, different studies have been performed to increase the working performance of the generators, including modifications in the structural properties [11], changes in the geometry of the legs [12], enhancing the figure of merit [13], and optimisation of the mechanical system and functioning temperatures [8]. Annular TE generators were implemented to enhance the operating performance of thermoelectric generators (TEGs) by altering its geometric structure and parameters, and Fraisse et al. [14] stated that the variable segment had an effect on thermoelectric performance.
An investigation carried out by Erturun et al. [12] aimed to study potential effects on the thermo mechanical efficiency and power generation of thermoelectric instruments from different thermoelectric leg geometries. In this way, thermoelectric modules with different leg geometries were simulated and finite element analysis was performed using ANSYS for two different temperature gradients. Each model has been evaluated for its thermal distribution, electricity output, conversion efficiency and thermal stresses in the legs. Due to altering leg geometries, there were significant variations in size and distribution of the thermal stresses in the legs. The report reveals that due to the varied leg configurations, temperature distributions, power outputs and conversion efficiencies were substantially changed, and it also concluded that the differing leg geometry may potentially improve the module. In addition, the researchers have demonstrated that less thermal stress is faced by a leg configuration with rounded curves than those with sharp edges, indicating that the greatest thermal stress accrues in the Rectangular geometry.
Using the Finite Element method, Al-Merbati et al. [15] carried out a study that investigated the relationship of thermal stress with output power and thermal performance of thermoelectric generators with variable pin leg geometry. For specific geometrical configurations of the unit, it was observed that changing the geometry of the pin increases the variation in temperature in the thermoelectric generator, thus reducing the overall stress levels in the pin. As a result, the life expectancy of the device can be increased by the geometrical configuration of the device pins.
The thermoelectric and mechanical performance of a segmented annular thermoelectric generator (SATEG) was investigated by Samson et al. [16], who employed three-dimensional finite element analysis. Additionally, the effect of segmented pin geometry on the output of the segmented annular thermoelectric generator was studied and a comparison was made with non-segmented annular thermoelectric generators. The study revealed that when the temperature differential is greater than 100K, the segmented annular thermoelectric generator has a higher efficiency compared to the annular thermoelectric generator (ATEG) with Bismuth telluride material. Moreover, while studying the thermal stresses of segmented annular TEGs, the Von Mises stress has been reported to decrease as the angle between the thermoelectric legs increases.
Computational simulation was used by Tian et al. [17] to explore the hollow cylindrical TEG configuration as a novel leg arrangement for the thermoelectric module in which the n-type and p-type legs are positioned co-axially within each other. The findings indicate that a rise in hot side temperature will boost the output power and conversion efficiency of the cylindrical thermoelectric generator (CTEG) but decrease the mechanical stability of the device. In comparison, with an improvement in the slanting angle of thermoelectric legs, the overall tension of Von Mises in the legs increases and the power output of the CTEG increases. The increase in the width ratio leads to a boost in output power and a decrease in conversion and energy efficiency.
A theoretical review of the thermoelectric power generator was carried out, and the effects of the geometry of the thermoelectric leg on the efficiency of the system and the production of power were studied by Ahmet and Bekir [18]. The shape parameter was correlated with the geometric structure of the legs in the device and integrated into the analysis. For different temperature and external load resistance ratios, the effect of the form parameter on the unit performance and power generation was studied. Overall, the efficiency of the thermoelectric generators was found to increase for certain ranges of the shape parameter; nevertheless, it has a negative effect on power generation.
The modeling of a multi-element thermoelectric generator with irreversibility demonstrated a significant predictor of the performance of TEG energy efficiency, exergy efficiency and the system power production [19].
Ravita and Kaushik [20] conducted a thermodynamic analysis of a extroversible thermoelectric generator involving the Thomson effect and the influence of leg geometry on the device’s power production and performance. The authors calculated mathematically the power output, irreversibility, energy and exergy efficiency considering the Thomson effect. The finding of the analysis indicated that when the shape parameter was increased from a flat plate TEG to a trapezoidal TEG, the energy and exergy efficiency improved as well.
A research study [21] used a simulation tool for thermoelectric generators based on steady-state equations and experimental evidence to investigate the efficiency of TEGs with continuous heat through them, and to find the optimal geometric configuration, leading to better performance and lowest material expense. The authors also introduced the electrical characterisation of TEGs for constant-heat and explored the relationship between the maximal power point and the open-circuit voltage, the maximum strength of TEGs with legs of various sizes and numbers and packing factors for different heights.
Since the overall usable heat in most waste heat applications is always constrained, the researchers optimised the efficiency for the most realistic condition and reported that the optimum value for the current would be achieved if the steady state of the open-circuit voltage was twice the load voltage. Overall, the findings show that the packing factor and the clearance space substantially affect the power output of a module with a set amount of thermal power.
The effect of pin leg geometry on the thermal efficiency of the system was thermodynamically developed by Haider et al. [22]. The effects of dimensionless geometric parameters on efficiency and power production were demonstrated for various temperature ratios and external load resistance ratios. Increasing dimensionless geometric parameters has been found to increase the thermal performance of the device, but the maximum efficiency point does not correspond with the maximum output power point of the device.
A detailed mathematical model was suggested by Linhao et al. [23] to calculate the optimum leg length and cross-sectional area of the TEG unit and to optimise the peak output capacity. The model suggests that there is an ideal ratio of leg length and leg cross-sectional area for a TEG unit corresponding to the maximum peak output power with a fixed boundary condition, and it is possible to further determine the optimal leg length and cross-sectional area depending on the optimal ratio.
Although comprehensive studies have been conducted to investigate the efficiency of different thermoelectric systems, geometric configurations of variable cross-section thermoelectric legs have not been given sufficient attention throughout the reviewed literature. Therefore, the purpose of this research is to thoroughly investigate the effect and performance of thermoelectric generators with new leg geometries, not previously examined in the literature. The leg geometries studied include the traditional Rectangular shape as a reference module and two new configurations: the Diamond shape and the Cone-based shape. Using COMSOL Multiphysics (COMSOL Ltd., Cambridge, UK) temperature distributions, voltage potential and thermal stress analyses were carried out for the proposed leg configuration (each consisting of two pairs p and n). In addition, the electrical analysis for TEG modules consisting of 128 pairs of legs was conducted for two cases generating the lowest and the highest voltages for a double pair of legs.

2. Equivalent Electric Circuit for TEGs and Boundary Conditions

TEG power generation relies heavily on both the temperature difference over the semiconductor components and the electrical load, according to Seebeck, Peltier and Thomson effects. Figure 1 indicates a schematic electric circuit equivalent to the thermoelectric generator. This circuit aims to explain the fundamental objective of the thermoelectric generator. If there is no connection to the load, the open circuit voltage ( V o c ) is given as:
V o c = α Δ T
where Δ T = T h T c represents the temperature difference between the hot and cold plates, and the Seebeck coefficient, which is responsible for causing the current to flow (in the case of temperature gradient), is indicated as α .
Once an external load resistance ( R L ) is attached, the output voltage of the thermoelectric generator ( V L ) is defined as the following [16]:
V L = V o c R i n I = R L I
if R i n   is the TEG’s internal resistance and I is the TEG current, which can be defined as [16]:
I = V o c R i n + R L = α Δ T R i n + R L
Finally, the thermoelectric generator’s output power P o u t can be obtained from [24]:
P o u t = V L I = R L I 2 = R L · α 2 · Δ T 2 ( R i n + R L ) 2
Through integrating many thermoelectric components, the necessary power output for a specific application can be achieved. Furthermore, the output voltage and power of the thermoelectric generator can be maximised [16] by adding a high temperature differential to the thermoelectric generator and by balancing the external load resistance to its internal resistance.
The efficiency of the thermoelectric generator can be described from Equation (5), where Q i n is the heat input, and it can be obtained using the thermoelectric coupling equations.
η = P o u t Q i n
In addition to the output power of a thermoelectric generator, the electrical power density is another significant parameter that specifically affects the very critical TEG efficiency and cost ratio for waste heat recovery applications. Means to increase the thermoelectric generator power efficiency involve enhancing the figure of merit, raising the temperature differential around the TEG and optimising thermoelectric element measurements and filling factors [25].
The Seebeck effect converts temperature differences to electricity, the Peltier effect converts electricity to temperature differences and the Thomson effect is the heat formed by the combination of current density and temperature gradients. The Seebeck coefficient is largely used in the COMSOL formulation. Although the Peltier coefficient is utilised as an intermediate variable, the Thomson coefficient was not employed in the analysis [26].

2.1. Boundary Conditions

In principle, a TEG unit is a thermopile consisting of a set of semiconductor pairs of p and n type materials connected electrically in series. Heat carries the majority of carriers that produce current and voltage between one connection and another. A TEG module produces an open-circuit voltage proportional to the temperature difference over the components by positioning multiple p and n couples in series electrically and thermally in parallel [27].
The main boundary conditions for TEG models are described as the following in order to clarify the analysis:
  • A heat transfer module was used for the measurement of the temperature difference in the thermoelectric generator by conduction and convection with surface-to-surface temperature distribution.
  • All surfaces except the hot and cold junction surfaces are adiabatic. Therefore, convective heat transfer was not considered for this simulation.
  • A steady-state condition was assumed for the thermoelectric modules. Addıtıonally, on the surfaces of the TEG, an adiabatic situation is considered, with no heat loss.
  • Thermal boundary conditions are known as heat source (hot surface) and heat sink (cold surface) with defined temperatures of 293 K and 393 K, respectively, for the cold source and hot surface. In the module, a coherent mesh to describe the electrical and thermomechanical properties was considered.
  • Internal electrical and thermal contact resistance are neglected.

2.2. Numerical Model

COMSOL Multiphysics is software that allows for the creation of models by defining parameters, building a geometry, applying the physics, creating the mesh, solving the model and then visualising and postprocessing the results.
COMSOL 5.5 Multiphysics software was employed to undertake a finite element analysis and to extract thermoelectric and mechanical performance data from the TEG examined. The analysis was conducted under steady-state conditions. The copper electrode on the cold n-leg surface has zero electrical potential, while a terminal on the cold p-leg is attached to the copper electrode. All materials are known to be linear elastic materials, and Table 1 lists their corresponding properties. The Seebeck coefficient, electrical resistivity and thermal conductivity, which are temperature-dependent properties of the materials used, are available in COMSOL and presented in the articles [11,16,28].
The principal equation of the thermoelectric analysis was derived through COMSOL Multiphysics 5.5 software, the investigation considers the Peltier effect, Fourier effect, Joule effect and Thomson effect. The heat flow equation in thermoelectric analysis can be written as [6]:
ρ d C p T t + · q = q   ˙
in which the density is represented as ρ d   ( kg / m 3 ) , the specific heat capacity is shown as C p ( J kg × K ) , q     ( W / m 2 )   indicates the heat flux vector, q ˙ ( W / m 3 )   is the heat generation rate per unit volume and T   ( K ) is the absolute temperature.
The continuity of electric charge can be obtained from the equation below [29]:
· ( J   + D t ) = 0
where J   is the electric current density vector ( A / m 2 ) and D     ( C / m 2 ) is the electric flux density vector.
Equations (6) and (7) are combined employing appropriate fundamental thermoelectric equations [30]:
q   = T [ α ] · J   [ κ ] · T
J   = [ σ ] · ( E [ α ] · T )
[ α ] represents the Seebeck coefficient matrix, the thermal conductivity matrix is shown as [ κ ] and [ σ ]   is the electrical conductivity matrix. E indicates the electric field intensity and it can be deduced from [30]:
E = φ
φ represents the electric scalar potential. Incorporating Equations (8)–(10), Equations (6) and (7) can rearranged as below:
ρ d C p T t + [ ( T [ α ] · J   ) ( [ α ] · T ) ] = q   ˙
[ ( [ ε ] · φ t ) + ( [ σ ] · [ α ] · T ) + ( [ σ ] · φ ) ] = 0
The ratio between the electric field inside a material and the resulting electric displacement is known as dielectric permittivity [31]. [ ε ] indicates the dielectric permittivity matrix and its unit is ( F m ) .

2.3. Analysis of Thermal Stresses

The following thermal differential equation was included in the thermodynamic analysis:
x ( k T x ) + y ( k T y ) + z ( k T z ) = 0
in which k = f ( T ) and T = f ( x , y , z ) [32]. Hence, the irregular and disproportionate expansions of the TEG materials will lead to the creation of thermal stresses. It is possible to describe the equations governing the displacement-strain relations of thermal stress as follows [32]:
ε ¯ x x = u ¯ x ¯ ,   ε ¯ y y = v ¯ y ¯ ,   ε ¯ z z = w ¯ z ¯
ε ¯ x y = ( u ¯ y ¯ + v ¯ x ¯ ) 2 ,   ε ¯ y z = ( w ¯ y ¯ + v ¯ z ¯ ) 2 ,   ε ¯ x z = ( w ¯ x ¯ + u ¯ z ¯ ) 2
Thus, the relation of stress-strain may be described in a dimensionless form using a nonsymmetric Jacobian matrix as [33]:
{ σ ¯ x x σ ¯ y y σ ¯ z z σ ¯ y z σ ¯ x z σ ¯ x y } = E ¯ ( 1 + v ) ( 1 2 v ) [ 1 v v v 0 0 0 v 1 v v 0 0 0 v v 1 v 0 0 0 0 0 0 1 2 v 0 0 0 0 0 0 1 2 v 0 0 0 0 0 0 1 2 v ] { ε ¯ x x   ε ¯ y y ε ¯ z z ε ¯ y z ε ¯ x z ε ¯ x y } { 1 1 1 0 0 0 } α ¯ E ¯ T ¯ 1 2 v
The equivalent Von Mises stress is shown in Equation (17) in order to express the total combined stress in all three dimensions [15]:
σ V M = 1 2 × [ ( σ 1 σ 2 ) 2 + ( σ 2 σ 3 ) 2 + ( σ 3 σ 1 ) 2 ]

3. Conceptual Geometries

The models under consideration are variable cross-section leg TEGs; B i 2 T e 3 was selected as the base material for the design, and the p and n type legs were thermally connected in parallel (electrically in series) through copper electrodes. Moreover, thermoelectric elements and copper electrodes were placed between two alumina ceramic plates to sustain the mechanical stress between the hot and cold junctions while avoiding electric interaction.
The geometries under investigation consisted of three different legs shapes, one of which was of an established geometry, and the other two were developed specifically for this research. The unique models are all shown in Figure 2B,C. All geometries are of the same dimensions of 5   mm × 6   mm × 1.5   mm and hot junction cross sectional area. More details can be found in Table 2. The legs with Rectangular geometry (Figure 2A) are the current standard leg geometry, which has been chosen as a reference.

4. Result and Discussion

TEGs (with two pairs of legs p and n) of various variable leg geometries, such as the Diamond and Cone shape (Figure 2), have been fully modelled and their performance comprehensively investigated. In addition, a thermal stress analysis was performed. In all designs, the numerical computations were carried out in a steady-state condition with the hot and cold ceramic plates in contact with the junctions at 393 K and 293 K, respectively.
Generating an appropriate mesh is essential to achieve accurate results within the shortest time possible. For each design, three types of meshing were carried out (Coarser, Normal and Extra-Fine), and the results are indicated in Table 3. Therefore, for this research, for the Cone- and Diamond-shaped models, the coarser mesh was chosen; however, for the Rectangular model, the Extra-Fine mesh was simulated as it produced more voltage potential (4 × 10−4 V) in comparison to the other generated meshes.

4.1. Temperature Distribution Analyses

The thermoelectric effect interface in COMSOL Multiphysics was utilised for this study. This Multiphysics interface includes an interface for electric currents as well as an interface for heat transfer in solids. The Multiphysics coupling incorporates the thermoelectric effect, electromagnetic power dissipation and temperature-dependent electromagnetic material characteristics. Because the built-in thermal insulation was provided to all surfaces except the hot and cold connections, convective heat transfer was not included for this simulation.
Figure 3A–C indicates the temperature distributions of the various models. As it is shown, the temperature falls rapidly from the hot junction to the cold junction. Figure 3D compares the various models. The results indicate that the Rectangular leg shape experienced a comparatively smooth course, which was also demonstrated from the results obtained in the study conducted by O. Ibeagwu [34]. The Diamond-shaped and the Cone-shaped geometries experienced different courses, perhaps due to their geometries and cross-sectional areas. The simulations for the Rectangular leg were found to be a close match to the literature data from O. Ibeagwu [34], which was concluded to be a validation of the model.

4.2. Electrical Analysis

The electric potential analysis is shown in Figure 4A–C. Thermoelectric elements are thermally connected in parallel and electrically connected in series; therefore, and as it can be seen, the voltage potential varies from one side of the models to the other end. Moreover, from Figure 4D, it can be clearly observed that both the innovative Cone-shaped TEG model and the Diamond-shaped TEG model produced higher voltage potentials than the conventional Rectangular-shaped TEG. While this difference in electrical potential between different leg shapes is minor (only 3.5 × 10 3   V ) , it has a significant impact as many thermoelectric instruments are operated in sequence. Therefore, the influence of the shape of the legs on the voltage of the whole TEG module built from 128 pairs was analysed. Figure 5 presents the results of the analysis carried out. The generated voltage for two pairs of Diamond leg designs was 0.09 V, and for the Rectangular design 0.089 V, for 128 pairs, theoretically it should be 5.76 V for the Diamond shape and 5.68 V for the Rectangular shape; however, the computational simulation indicated 5.68 V and 5.67 V for the Diamond and Rectangular shapes, respectively.

4.3. Thermal Stress Analysis

Thermal stress inside the device restricts the temperature difference in potential implementation because it can shorten the lifetime of the TEGs. Furthermore, material failure caused by high stress-induced cracking prevents the system from performing as intended. As a result, research into the formation and development of thermal stress in the thermoelectric system is vital [15], particularly considering their long-term operation.
The thermal stress distribution is indicated in Figure 6A–C. The thermal stress evaluation was achieved by relating the thermal and structural stresses to the temperatures employed at hot and cold junctions. As shown in the figure, the maximum von Mises stress appears at the hot junction side, which validates the results obtained by reference [34]. The maximum von Mises stress for the Diamond-shaped model was noted as 1.45 × 10 8   Pa , which was less in comparison to the maximum von Mises stress for both the Rectangular and the Cone shapes by 1.74 × 10 8   Pa .
Figure 6D was provided in order to explain the stress pattern and the von Mises distribution throughout the leg geometries. As it is demonstrated by the figure, stresses for all three models dropped sharply from the hot junction and then rose over approximately 1 mm, which is in agreement with the results obtained by [34].
In comparing the results, the stress in the Diamond-shaped leg had two peaks at about 1 and 4 mm from the top (hot junction) and a decrease in the middle part of the model. With the Cone-shaped design, after the sharp decrease, the von Mises stress gradually increased until just before 4 mm from the hot junction where it experienced another decline. With the Rectangular shape, after the decrease at the beginning, the stress rose to 4 × 10 7   Pa , which stayed fairly constant with only a slight decline until the bottom side, where its von Mises value experienced another fall. Overall, it can be deduced that the thermal stress formed in the thermoelectric modules largely depends on the leg geometry.
The thermal stress is more developed in the area close to the hot junctions; the maximal stress occurs around the leg edges as well.

5. Conclusions

In this study, modelling and performance investigations were performed for two types of thermoelectric legs not previously analysed in the literature with geometries classified as Cone-shaped and Diamond-shaped, and the results were compared with Rectangular-shaped legs, which were selected as a reference. In the first stage of research, TEG modules built from two pairs p and n were analysed. The effect on thermal conductivity, electrical resistivity and stress analysis of the leg configuration was analysed in the various geometries using temperature dependent properties of B i 2 T e 3 with a numerical and computational method. The calculation was performed at fixed conditions, the hot junction was assumed to be 393 K and the cold junction was 293 K.
From the results obtained, it was observed that the temperature distribution was impacted greatly by the variable leg geometry along the leg height. For instance, the conventional Rectangular shape experienced a smoother temperature distribution compared to the Cone and Diamond shapes. In terms of the electric potential, the newly introduced Diamond shape showed the highest voltage potential in comparison to the Rectangular shape, which had the lowest voltage potential. Furthermore, at the second stage of the research, the whole module consisting of 128 pairs p and n for the two most different results was analysed. It is worth noting that the voltage for a TEG module was 5.67 V and 5.68 V for Rectangular and Diamond shapes, respectively, and the results were found to be comparable to the theoretical analysis.
Using COMSOL Multiphysics coupling features, stress analysis was performed on all the models and the hot junctions experienced the maximum stresses. The maximum von Mises stress for the Diamond-shaped model was noted as 1.45 × 10 8   Pa , which was less in comparison to the maximum von Mises stress for both the Rectangular and the Cone shapes by 1.74 × 10 8   Pa .   Moreover, all the geometries experienced a steep decline in stress levels with distance followed by an increase in their particular values. In addition, it was observed that the Diamond shape, which experienced the least stress in comparison to the other designs, had the largest voltage potential. It should be noted that this is a preliminary study for various leg geometries, and it is only focused on steady-state processes. In a future study, the effect of a time dependent domain can be investigated through the defined approach.

Author Contributions

Conceptualization, Q.D., N.K., A.Ż.-G., L.A., L.N., D.A. and H.J.; methodology, Q.D., N.K., A.Ż.-G., L.A., L.N., D.A. and H.J.; software, Q.D., N.K. and A.Ż.-G.; validation, Q.D., N.K. and A.Ż.-G.; formal analysis, Q.D., N.K. and A.Ż.-G.; investigation, Q.D., N.K. and A.Ż.-G..; resources, Q.D., N.K., A.Ż.-G., L.A., L.N., D.A. and H.J.; data curation, Q.D., N.K. and A.Ż.-G.; writing—original draft preparation, Q.D., N.K., A.Ż.-G., L.A., L.N., D.A. and H.J.; writing—review and editing, H.J.; visualization, Q.D., N.K., A.Ż.-G., L.A., L.N., D.A. and H.J; supervision, H.J.; All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded from the European Union’s Horizon 2020 Research and Innovation Programme for project InComEss under Grant Agreement Number 862597.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Acknowledgments

This work has been receiving financial support from the European Union’s Horizon 2020 Research and Innovation Programme for project InComEss under Grant Agreement Number 862597.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Malinauskaite, J.; Jouhara, H.; Ahmad, L.; Milani, M.; Montorsi, L.; Venturelli, M. Energy efficiency in industry: EU and national policies in Italy and the UK. Energy 2019, 172, 255–269. [Google Scholar] [CrossRef]
  2. Fierro, J.J.; Escudero-Atehortua, A.; Nieto-Londoño, C.; Giraldo, M.; Jouhara, H.; Wrobel, L.C. Evaluation of waste heat recovery technologies for the cement industry. Int. J. Thermofluids 2020, 7–8, 100040. [Google Scholar] [CrossRef]
  3. Venturelli, M.; Brough, D.; Milani, M.; Montorsi, L.; Jouhara, H. Comprehensive numerical model for the analysis of potential heat recovery solutions in a ceramic industry. Int. J. Thermofluids 2021, 10, 100080. [Google Scholar] [CrossRef]
  4. Brough, D.; Ramos, J.; Delpech, B.; Jouhara, H. Development and validation of a TRNSYS type to simulate heat pipe heat exchangers in transient applications of waste heat recovery. Int. J. Thermofluids 2021, 9, 100056. [Google Scholar] [CrossRef]
  5. Egilegor, B.; Jouhara, H.; Zuazua, J.; Al-Mansour, F.; Plesnik, K.; Montorsi, L.; Manzini, L. ETEKINA: Analysis of the potential for waste heat recovery in three sectors: Aluminium low pressure die casting, steel sector and ceramic tiles manufacturing sector. Int. J. Thermofluids 2019, 1–2, 100002. [Google Scholar] [CrossRef]
  6. Xiao, J.; Yang, T.; Li, P.; Zhai, P.; Zhang, Q. Thermal design and management for performance optimization of solar thermoelectric generator. Appl. Energy 2012, 93, 33–38. [Google Scholar] [CrossRef]
  7. Talawo, R.-C.; Fotso, B.E.M.; Fogue, M. An experimental study of a solar thermoelectric generator with vortex tube for hybrid vehicle. Int. J. Thermofluids 2021, 10, 100079. [Google Scholar] [CrossRef]
  8. Jouhara, H.; Żabnieńska-Góra, A.; Khordehgah, N.; Doraghi, Q.; Ahmad, L.; Norman, L.; Axcell, B.; Wrobel, L.; Dai, S. Thermoelectric generator (TEG) technologies and applications. Int. J. Thermofluids 2021, 9, 100063. [Google Scholar] [CrossRef]
  9. Maghrabie, H.M.; Elsaid, K.; Sayed, E.; Abdelkareem, M.; Wilberforce, T.; Ramadan, M.; Olabi, A.G. Intensification of heat exchanger performance utilizing nano fluids. Int. J. Thermofluids 2021, 10, 100071. [Google Scholar] [CrossRef]
  10. Soleimani, S.; Eckels, S. A review of drag reduction and heat transfer enhancement by riblet surfaces in closed and open channel flow. Int. J. Thermofluids 2021, 9, 100053. [Google Scholar] [CrossRef]
  11. Gao, J.-L.; Du, Q.-G.; Zhang, X.-D.; Jiang, X.-Q. Thermal Stress Analysis and Structure Parameter Selection for a Bi2Te3-Based Thermoelectric Module. J. Electron. Mater. 2011, 40, 884–888. [Google Scholar] [CrossRef]
  12. Erturun, U.; Erermis, K.; Mossi, K. Effect of various leg geometries on thermo-mechanical and power generation performance of thermoelectric devices. Appl. Therm. Eng. 2014, 73, 128–141. [Google Scholar] [CrossRef]
  13. Zhang, X.; Zhao, L.-D. Thermoelectric materials: Energy conversion between heat and electricity. J. Mater. 2015, 1, 92–105. [Google Scholar] [CrossRef] [Green Version]
  14. Fraisse, G.; Lazard, M.; Goupil, C.; Serrat, J.Y. Study of a thermoelement’s behaviour through a modelling based on electrical analogy. Int. J. Heat Mass Transf. 2010, 53, 3503–3512. [Google Scholar] [CrossRef] [Green Version]
  15. Al-Merbati, A.S.; Yilbas, B.S.; Sahin, A.Z. Thermodynamics and thermal stress analysis of thermoelectric power generator: Influence of pin geometry on device performance. Appl. Therm. Eng. 2013, 50, 683–692. [Google Scholar] [CrossRef]
  16. Shittu, S.; Li, G.; Zhao, X.; Ma, X.; Akhlaghi, Y.G.; Ayodele, E. High performance and thermal stress analysis of a segmented annular thermoelectric generator. Energy Convers. Manag. 2019, 184, 180–193. [Google Scholar] [CrossRef]
  17. Tian, M.-W.; Mihardjo, L.W.W.; Moria, H.; Asaadi, S.; Pourhedayat, S.; Sadighi Dizaji, H.; Wae-hayee, M. Economy, energy, exergy and mechanical study of co-axial ring shape configuration of legs as a novel structure for cylindrical thermoelectric generator. Appl. Therm. Eng. 2021, 184, 116274. [Google Scholar] [CrossRef]
  18. Sahin, A.Z.; Yilbas, B.S. The thermoelement as thermoelectric power generator: Effect of leg geometry on the efficiency and power generation. Energy Convers. Manag. 2013, 65, 26–32. [Google Scholar] [CrossRef]
  19. Xiao, H.; Gou, X.; Yang, S. Detailed Modeling and Irreversible Transfer Process Analysis of a Multi-Element Thermoelectric Generator System. J. Electron. Mater. 2011, 40, 1195–1201. [Google Scholar] [CrossRef]
  20. Lamba, R.; Kaushik, S.C. Thermodynamic analysis of thermoelectric generator including influence of Thomson effect and leg geometry configuration. Energy Convers. Manag. 2017, 144, 388–398. [Google Scholar] [CrossRef]
  21. Montecucco, A.; Siviter, J.; Knox, A.R. Constant heat characterisation and geometrical optimisation of thermoelectric generators. Appl. Energy 2015, 149, 248–258. [Google Scholar] [CrossRef] [Green Version]
  22. Haidar, J.G.; Ghojel, J.I. Waste heat recovery from the exhaust of low-power diesel engine using thermoelectric generators. In Proceedings of the ICT2001, 20 International Conference on Thermoelectrics (Cat. No.01TH8589), Beijing, China, 8–11 June 2001; pp. 413–418. [Google Scholar]
  23. Fan, L.; Zhang, G.; Wang, R.; Jiao, K. A comprehensive and time-efficient model for determination of thermoelectric generator length and cross-section area. Energy Convers. Manag. 2016, 122, 85–94. [Google Scholar] [CrossRef]
  24. Singh, S.; Ibeagwu, O.I.; Lamba, R. Thermodynamic evaluation of irreversibility and optimum performance of a concentrated PV-TEG cogenerated hybrid system. Sol. Energy 2018, 170, 896–905. [Google Scholar] [CrossRef]
  25. Zhang, Y.; Cleary, M.; Wang, X.; Kempf, N.; Schoensee, L.; Yang, J.; Joshi, G.; Meda, L. High-temperature and high-power-density nanostructured thermoelectric generator for automotive waste heat recovery. Energy Convers. Manag. 2015, 105, 946–950. [Google Scholar] [CrossRef] [Green Version]
  26. COMSOL. Heat Transfer Module, 2018.
  27. Massaguer, E.; Massaguer, A.; Montoro, L.; Gonzalez, J.R. Development and validation of a new TRNSYS type for the simulation of thermoelectric generators. Appl. Energy 2014, 134, 65–74. [Google Scholar] [CrossRef]
  28. Li, G.; Zhao, X.; Jin, Y.; Chen, X.; Ji, J.; Shittu, S. Performance Analysis and Discussion on the Thermoelectric Element Footprint for PV–TE Maximum Power Generation. J. Electron. Mater. 2018, 47, 5344–5351. [Google Scholar] [CrossRef] [Green Version]
  29. Antonova, E.E.; Looman, D.C. Finite elements for thermoelectric device analysis in ANSYS. In Proceedings of the ICT 2005, 24th International Conference on Thermoelectrics, Clemson, SC, USA, 19–23 June 2005; pp. 215–218. [Google Scholar]
  30. Landau, L.D.; Pitaevskii, L.P.; Lifshitz, E.M. Pitaevsky LP Electrodynamics of Continuous Media, 2nd ed.; Elsevier: Amsterdam, The Netherlands, 2004. [Google Scholar]
  31. GitHub. Dielectric Permittivity. Available online: https://em.geosci.xyz/content/physical_properties/dielectric_permittivity/index.html#contents (accessed on 26 March 2021).
  32. Ming, T.; Yang, W.; Wu, Y.; Xiang, Y.; Huang, X.; Cheng, J.; Li, X.; Zhao, J. Numerical analysis on the thermal behavior of a segmented thermoelectric generator. Int. J. Hydrogen Energy 2017, 42, 3521–3535. [Google Scholar] [CrossRef]
  33. Ootao, Y.; Tanigawa, Y. Three-dimensional solution for transient thermal stresses of functionally graded rectangular plate due to nonuniform heat supply. Int. J. Mech. Sci. 2005, 47, 1769–1788. [Google Scholar] [CrossRef]
  34. Ibeagwu, O.I. Modelling and comprehensive analysis of TEGs with diverse variable leg geometry. Energy 2019, 180, 90–106. [Google Scholar] [CrossRef]
Figure 1. TEG Equivalent electrical circuit [16].
Figure 1. TEG Equivalent electrical circuit [16].
Chemengineering 05 00045 g001
Figure 2. Geometry of the TEG legs analysed: (A) Rectangular shape, (B) Diamond shape and (C) Cone shape.
Figure 2. Geometry of the TEG legs analysed: (A) Rectangular shape, (B) Diamond shape and (C) Cone shape.
Chemengineering 05 00045 g002
Figure 3. Comparison of TEG Temperature Distributions of (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) temperature distributions for the geometries analysed.
Figure 3. Comparison of TEG Temperature Distributions of (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) temperature distributions for the geometries analysed.
Chemengineering 05 00045 g003
Figure 4. The electric potential produced in (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) Voltage Comparison.
Figure 4. The electric potential produced in (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) Voltage Comparison.
Chemengineering 05 00045 g004
Figure 5. Electrical potential produced in (A) Rectangular shape and (B) Diamond shape.
Figure 5. Electrical potential produced in (A) Rectangular shape and (B) Diamond shape.
Chemengineering 05 00045 g005
Figure 6. The Stress analysis in (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) Von Mises Comparison.
Figure 6. The Stress analysis in (A) Rectangular shape, (B) Diamond shape, (C) Cone shape and (D) Von Mises Comparison.
Chemengineering 05 00045 g006aChemengineering 05 00045 g006b
Table 1. TEG Material Properties.
Table 1. TEG Material Properties.
MaterialThermal Conductivity (W/m K)Electrical Conductivity (S/m)Seebeck Coefficient (V/K)Young’s Modulus (Pa)Poisson’s Ratio
B i 2 T e 3 P   t y p e k(T)Sigma(T)S(T)6.5 × 10100.23
B i 2 T e 3 N   t y p e k(T)Sigma(T)−S(T)6.5 × 10100.23
Copper4005.9 × 107-110 × 1090.35
Alumina27--330 × 1090.22
Table 2. TEG model dimensions.
Table 2. TEG model dimensions.
Model NameRectangularConeDiamond
Parameter
Cu (mm)0.1 × 1 × 2.50.1 × 1 × 3.250.1 × 1 × 2.5
Alumina (mm)0.3 × 2 × 60.3 × 2 × 60.3 × 2 × 6
Hot Junction Cross Sectional Area (mm2)1 × 11.770.5 × 0.5
Cold Junction Cross Sectional Area (mm2)1 × 10.780.5 × 0.5
Cross Sectional Area (mm2) at the Middle1 × 11.171 × 1
Table 3. Summary of the mesh types under consideration: TEG geometry, number of elements and mesh type.
Table 3. Summary of the mesh types under consideration: TEG geometry, number of elements and mesh type.
ModelNumber of ElementsAverage Element QualityMesh Type
Cone-Leg15380.494Coarser
15,3080.628Normal
96,9110.661Extra-Fine
Diamond4880.327Coarser
57760.598Normal
41,2220.670Extra-Fine
Rectangular5400.405Coarser
90010.623Normal
61,2090.669Extra-Fine
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Doraghi, Q.; Khordehgah, N.; Żabnieńska-Góra, A.; Ahmad, L.; Norman, L.; Ahmad, D.; Jouhara, H. Investigation and Computational Modelling of Variable TEG Leg Geometries. ChemEngineering 2021, 5, 45. https://doi.org/10.3390/chemengineering5030045

AMA Style

Doraghi Q, Khordehgah N, Żabnieńska-Góra A, Ahmad L, Norman L, Ahmad D, Jouhara H. Investigation and Computational Modelling of Variable TEG Leg Geometries. ChemEngineering. 2021; 5(3):45. https://doi.org/10.3390/chemengineering5030045

Chicago/Turabian Style

Doraghi, Qusay, Navid Khordehgah, Alina Żabnieńska-Góra, Lujean Ahmad, Les Norman, Darem Ahmad, and Hussam Jouhara. 2021. "Investigation and Computational Modelling of Variable TEG Leg Geometries" ChemEngineering 5, no. 3: 45. https://doi.org/10.3390/chemengineering5030045

APA Style

Doraghi, Q., Khordehgah, N., Żabnieńska-Góra, A., Ahmad, L., Norman, L., Ahmad, D., & Jouhara, H. (2021). Investigation and Computational Modelling of Variable TEG Leg Geometries. ChemEngineering, 5(3), 45. https://doi.org/10.3390/chemengineering5030045

Article Metrics

Back to TopTop