Article

Effects of a Graphene Heating Device on Fatigue Recovery of Biceps Brachii

1
Department of Sports Science, Zhejiang University, Hangzhou 310058, China
2
The MOF Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
*
Author to whom correspondence should be addressed.
Bioengineering 2023, 10(3), 381; https://doi.org/10.3390/bioengineering10030381
Submission received: 16 February 2023 / Revised: 5 March 2023 / Accepted: 16 March 2023 / Published: 21 March 2023

Abstract

:
Far-infrared (FIR) is considered to be an ideal method to promote fatigue recovery due to its high permeability and strong radiation. In this paper, we report a flexible and wearable graphene heating device to help fatigue recovery of human exercise by using its high FIR divergence property. This study compares two different fatigue recovery methods, graphene far-infrared heating device hot application and natural recovery, over a 20 min recovery time among the male colleges’ exhaustion exercise. Experimental results show that the achieved graphene device holds excellent electro-thermal radiation conversion efficiency of 70% and normal total emissivity of 89%. Moreover, the graphene FIR therapy in our work is more energy-efficient, easy to use, and wearable than traditional fatigue recovery methods. Such an anti-fatigue strategy offers new opportunities for enlarging potential applications of graphene film in body science, athletic training recovery, and wearable devices.

Graphical Abstract

1. Introduction

Since the training load and competition frequency of elite athletes are steadily increasing and performance differences between race winners and losers are becoming more and more marginal [1], athletes have to face the difficult task of maximizing training load and adaptation whilst avoiding insufficient recovery, which would lead to maladaptation, reduced performance, and increased risk of injury [2]. Rapidly increasing strength of competitive sports and developing national fitness have posed significant challenges to fatigue recovery measures [3]. Hence, efficient fatigue recovery is becoming a critical issue for improving the performance of athletes and relieving fatigue diseases. In response to these needs, a variety of treatment modalities (e.g., massage, relaxation activities, hydrotherapy, cryotherapy, electrical stimulation, cold-water immersion, hot–cold contrast baths, low-level laser, and stretching) [4,5,6,7] have been used as the main methods to enhance recovery during rest intervals in matches or between training sessions [8].
However, many conventional treatment modalities still usually suffer from low recovery efficiency, limited conditions for use, and lack of wearability. In recent years, numerous studies have reported that nanomaterials can not only be used as flexible, stretchable, and wearable sensors [9,10], but can also become an important method for fatigue recovery, especially far-infrared (FIR) emissive materials. Far-infrared radiation, an invisible electromagnetic wave with a characteristic wavelength of 5.6 to 1000 μm [1], is known for its radiative cooling function. It can be perceived as heat by the skin and has the ability to reflect heat energy from the sun, making it highly penetrating and radiative [11,12]. Therefore, it holds great potential for fatigue recovery of human muscles. Athletes may utilize various FIR techniques, such as FIR cabins/saunas, FIR ray devices, and the latest FIR-emitting garments. However, the requirement for precise molecular structures of current far-infrared ceramics and the laborious production process significantly reduces the product yield rate and manufacturing efficiency. In addition, the lack of wearability of far-infrared ceramics is also a formidable obstacle.
To achieve advanced far-infrared emissive materials with optimal performance, it is necessary to employ scalable and cost-effective fabrication approaches that incorporate novel chemicals, synthetic routes, and methodology. Graphene, an atomically thin sheet of carbon atoms arranged in a 2D hexagonal lattice [13], has attracted numerous attention for advanced materials due to its unique thermal and electrical conductivity, high mechanical strength, and optical properties [14,15,16]. It offers great potential for next-generation far-infrared emissive materials [17]. Macroscopic graphene film assembled from graphene sheets is expected to be an ideal far-infrared emissive material for physical therapy devices due to its combined merits of high far-infrared emissivity and flexibility [18]. However, there is no study on the effects of graphene on muscle recovery after a fatiguing activity based on its far-infrared divergence properties.
Fatigue may impair the joints’ kinesthetic and proprioceptive properties [19]. It increases muscle spindle discharge threshold, which interrupts afferent feedback, consequently altering joint awareness [19] affecting static postural control [20], and to a lesser degree, dynamic postural control [21,22,23,24,25]. At present, many studies have evaluated different methods for fatigue recovery [26,27]. However, the current research on FIR in the field of sports is mainly aimed at the whole body, and little research has been carried out on local fatigue recovery. In the field of competitive sports, the biceps brachii is the most important muscle in human upper limb movement, such as throwing motion, swing motion, lifting motion, and shooting motion. Muscle fatigue will affect the joint stability and athletic performance of athletes. It is of great significance to study the recovery effect of FIR on local fatigue of biceps brachii, so the effect of graphene heating film on fatigue recovery of biceps brachii is explored in this paper.

2. Materials and Methods

2.1. Materials

The graphene-based heating device (product number BZA170) used in this study was made by Hangzhou Gaoxi Technology Co., Ltd. (Gaoxi Technology, Hangzhou, China), which has almost the same far-infrared emission spectrum as the graphene heating product (No. HYY-118B) prepared by Grahope New Materials Technologies Inc. (GNM, Shenzhen, China) [18,28], and the former heating film is much more flexible and thus more suitable for this study than the latter. The graphene heating film was made by a continuous blade coating method with an aqueous slurry of graphene and additives. The film was cut into 8 cm × 15 cm piece, connected with two electrodes of copper foil, and covered with an insulation and flame retardant fabric, subsequently connected by a temperature controller and a power adaptor, affording the graphene heating device. As the device was turned on, electric energy was converted into heat energy and radiated out in the form of far-infrared wave. The rated power of the device was settled at 5 W, and the operating temperature was adjusted by the temperature controller between 30 °C and 55 °C.

2.2. Preparation

Here, we manufactured voltage-power adjustable flexible graphene heating devices, which have been utilized as heating elements in commercial body care products (G-Phoenix) (Gaoxi Technology, Hangzhou, China). Figure 1 illustrates the fabrication process of the flexible graphene heating devices by the film-forming of graphene slurry (FFGS) method. The FFGS technique is described as follows. The graphene paste and resin were mixed with deionized water. A dispersant was then added to the mixture to form a stable soliquid. After the stirring procedure, the soliquid became highly dispersed with low viscosity. The soliquid was further evacuated and defoamed. After that, the defoaming agent and the thickener were added; the soliquid was pressurized and filtered to coat into a film under the irradiation of a far-infrared oven. Finally, the graphene heating device was assembled from the graphene film using flame retardant fabric, power, transformer, etc.
Using the FFGS technique, we successfully fabricated a novel graphene far-infrared transmitter device with adjustable dimensions (Figure 2). The graphene heating device consists of three parts: the graphene film, the intelligent temperature controller, and the power adopter. It offers several advantages for infrared healthcare products: (1) it allows direct contact with the skin and can be heated automatically with adjustable temperature and voltage; (2) it has high intensity and abrasion resistance; (3) it can be prepared into different shapes to fit different parts of the human body; and (4) it exhibits high far-infrared emission efficiency and provides a comfortable warmth sensation.

2.3. Study Design

This pilot study was a prospective, randomized, controlled clinical trial. The recruited subjects who came to the lab for the study signed an informed consent form. This study was approved by the University Institutional Review Board and all participants provided written informed consent.

2.4. Participants

Thirty-six college students (all males) from general physical examination normal subjects of Zhejiang university were recruited to participate in the study. Thes inclusion criteria were: (1) healthy men; (2) age between 18–22 years old; (3) body mass index < 24 kg/m2; (4) right-handed. The exclusion criteria included: (1) previous injuries in the upper limb; (2) history of upper limb surgery; (3) cardio-respiratory problems; (4) history of neuromuscular or neurological pathologies; (5) inability to comply with fatigue protocol; (6) lack of consent. All participants were instructed to refrain from heavy exercise 48 h before testing to minimize confounding effects of physical activity levels. Table 1 illustrates the subject characteristics of groups A, B, C, and D. No significant difference was recorded between the groups in age, height, weight, and body mass index (p > 0.05).

2.5. Procedures

After taking a medical history and completing a physical examination, the participants’ age, body mass index (BMI, calculated as weight/height2 [kg/m2]), shoeless height (cm), and shoeless weight (kg) were determined, and the informed consent forms were signed. The participants were then randomly assigned into 4 groups: (A) control group, which received no graphene device treatment; (B) the 35 °C experimental group, which received graphene device treatment with 35 °C; (C) the 40 °C experimental group, which received graphene device treatment with 40 °C; and (D) the 45 °C experimental group, which received graphene device treatment with 45 °C. All tests and fatigue rating scale (RPE) showed as follows (Table 2) were conducted to evaluate the subjects at baseline before inducing muscle fatigue (T1), immediately after completing the fatigue protocol (T2), and after treatment for 20 min (T3). The measurements were made by a physiotherapist who was aware of the subjects’ group assignments. The FIR device is worn as in Figure 3. The FIR device was attached to the surface of the biceps brachii, and the heating end was placed on the upper end of the biceps brachii.

2.6. Measurement

  • Isometric peak force measurement
Measures of peak torque (PT) of the bicipital muscle of the arm were obtained on a Biodex System 4 Pro isokinetic dynamometer (Biodex Medical Systems, Inc., Shirley, New York, NY, USA) [29]. According to the manufacturer’s recommendations, calibrations were performed before the tests, and the axis of the dynamometer was aligned with that of the glenohumeral joint. Gravity corrections were employed during the tests. Conforming to the literature, all movements were carried out in the concentric-concentric mode [30,31]. All participants were given an explanation about the testing equipment and the procedure of assessment. The participant was tested in a sitting position with the chest and both shoulders against the chair seat, and the hip and knee angles at 90° [32]. The participants’ trunk was stabilized by two crossed straps from the contralateral shoulder across the chest and fixed with a buckle. Another strap was secured to the quadriceps table to fix the pelvis, and this position was stabilized by the other hand gripping a handle on the side of the Biodex chair. The ROM was from 0° to 120°. To ensure a high degree of subject compliance, our measurements were repeated if the coefficient of variance between the three repetitions was higher than 10%. One attempt with 3 repetitions was fulfilled in submaximal contractions (enough effort to clearly feel the resistance) in the same circumstances as the real tests. This trial was purposed to familiarize and prepare the participants for the real maximal test.
  • Fatigue protocol
The sitting posture dumbbell arm bend test (SDT) was used to induce biceps muscle fatigue. Fatigue was defined as a reduction in the force production of >30% of the peak force compared to the baseline pre-fatigue value. Exercises had been started at 70% of the three-repetitions maximum load of the individual previously determined, which consisted of 8–12 repetitions at above four sets at each session [33]. Between repetition sets, resting periods were 30 s approximately [34]. The participants were verbally encouraged to complete more sets until they could no longer perform the standard action.
  • Treatment
Group B, group C, and group D received graphene heating membrane therapy after exercise. After the preliminary experiment, the hot compress time for biceps muscle fatigue was determined at 20 min for the best effect. The hot compress temperatures were set at 35 °C, 40 °C, and 45 °C, respectively, to compare and analyze the effects of different temperature settings of graphene heating film on the fatigue recovery of biceps brachii. Serving as the control group, group A received the same period of static recovery for 20 min.

2.7. Statistical Analysis

The initial torque difference between different groups was tested by an independent sample t-test. A control group and 3 experimental groups (with temperature: 35 °C, 40 °C, and 45 °C) mixed factor analysis of variance (ANOVA) was conducted on muscle strength loss and recovery. Separate three-way mixed factor ANOVA was conducted to test the main interaction effects with and without graphene heating device, different temperatures (35 °C, 40 °C, and 45 °C) and phases (before experiment, after experiment, and after recovery of 20 min) on peak torque and stimulus for biceps brachii. The level of significance for all analyses was set at p < 0.05. Where required, post hoc comparisons were performed using simple effects tests with a predetermined alpha of 0.05. All analyses were conducted using SPSS 26 (IBM SPSS Statistics, New York, NY, USA).

3. Results

Graphene, a two-dimensional (2D) material, possesses remarkable mechanical strength (130 GPa), exceptional thermal conductivity (5300 W/mK), and superior electrical conductivity (108 S/m) [35,36]. Additionally, graphene exhibits excellent far-infrared radiation properties [18] and has a unique electronic structure that leads to distinctive optical properties [37]. It emits far-infrared light in the range of 8~15 μm, which coincides with the human body scattering band [18]. This characteristic makes it easily absorbed by human tissues, inducing a resonance effect that can penetrate far-infrared heat into subcutaneous tissues, promote blood circulation, dilate capillaries, and accelerate metabolism. Numerous studies on graphene have shown its unique properties in various research fields, which have generated new possibilities for the exploration of potential applications.
Far-infrared ray with strong penetration force and radiation force is easy to absorb by the object and turn into its internal energy [38]. It has a significant temperature control effect and resonance effect. When it is absorbed by the body, the blood flow in the skin is increased, the exchange between blood and tissue will be accelerated, and the toxin will be expelled from the body faster [39]. While the human body is made up of about 70 percent water, the far-infrared ray improves recovery efficiency by enhancing water activity. When infrared radiation penetrates through water, water molecules will absorb the radiant energy and the intermolecular forces will be reduced [40]. Large molecule groups will become smaller molecule groups. Therefore, the water density will be increased and water activity will be improved. Under the influence of infrared radiation, the effect of the penetration, proliferation, dissolution, cleaning, and emulsification of water will be enhanced and the metabolism will be accelerated. Recently, infrared radiation has been successfully used for healthcare [41], for the treatment of arthralgia, curvature, traumatic injuries, and the prolapse of the lumbar intervertebral disk and bone injuries.
Here, the graphene heating device was directly pasted on the fatigue site for the study of fatigue recovery. The specific experimental results are as follows. The peak torque, average peak torque, average peak torque per unit weight, coefficient of variance, and stimulus before/after exercise and after treatment within each group are shown in Table 3. There is neither a significant difference recorded between groups before and after exercise in peak torque, average peak torque, average peak torque per unit weight, coefficient of variance, and stimulus, nor significant difference recorded in group A before and after treatment in these data (p > 0.05). Nevertheless, there were significant increases before treatment compared with that after treatment in groups B, group C, and group D. Particularly, the peak torque, average peak torque, average peak torque per unit weight, and stimulus of group C after treatment were significantly different from those before treatment (p < 0.001). Taking the average peak torque as the standard, the fatigue rates of group A, group B, group C, and group D were, respectively, 66.76%, 69.01%, 69.18%, and 68.01% as calculated by the following formula. These dates were all less than 70% and there was no significant difference between each other. Similarly, the recovery rates of these four groups calculated by the formula below were 74.64%, 89.14%, 88.01%, and 84.72%, respectively. The difference between fatigue rate and recovery was 7.88%, 20.13%, 18.83%, and 16.71% among these four groups, which means that the recovery rate in the experimental groups treated with the graphene heating device was two~three times that of the normal control group.
The rate of fatigue = (after exercise)/(before exercise) × 100%
The rate of recovery = (after treatment)/(before exercise) × 100%
Difference = the rate of recovery − the rate of fatigue
The rank of immediate subjective feelings after exercise and post-treatment is shown in Table 4. There was no significant difference recorded between groups after exercise on the self-perception scale (p > 0.05). However, there were significant increases between groups post-treatment on the self-perception scale (p < 0.001). In addition, compared with group A, there were significant increases in group B and group C post-treatment on the self-perception scale.

4. Within-Group Comparison

Average peak torque was significantly increased after treatment compared with that before treatment in groups C (p < 0.001). In addition, a significant increase in group B (p < 0.01), and a little increase in group D (p < 0.05) were found, while no significant difference was found in average peak torque in group A (p > 0.05). (Table 5).
Fatigue level was significantly increased after treatment compared with that before treatment in groups A, B, C, and D (p < 0.001) (Table 5).

5. Between-Group Comparison

No significant difference was recorded between groups in average peak torque and fatigue level before treatment (p > 0.05).
No significant difference was noted in group A compared with the mean values of group B, group C, and group D after treatment (p > 0.05). Moreover, there was no significant difference recorded in the average peak torque of group B compared with that of group D after treatment and in the average peak torque of group C compared with that of groups B and D after treatment (p > 0.05) (Table 6).
A significant increase in average peak torque was reported in group A compared with the mean values of group C and group D after treatment (p < 0.05), while no significant difference was noted in group A compared with the mean values of group B after treatment (p > 0.05) (Table 6). Moreover, there was no significant difference recorded in the average peak torque of group B compared with that of group D after treatment and in the average peak torque of group C compared with that of group B and D post-treatment (p > 0.05).

6. Discussion

The aim of the current study is to verify the effects of different graphene heating film temperatures on the fatigue recovery of biceps brachii. Muscle fatigue can be defined as an exercise-induced decrease in force-generating capacity during maximal voluntary muscle contractions (MVC), or the inability to further sustain an exercise at a required force [42,43]. We hypothesized that the higher the temperature, the better the recovery effect of biceps brachii. According to the experimental results, compared with the control group, the graphene heating film at three different temperatures can promote fatigue recovery. In particular, the peak torque, average peak torque, average peak torque per unit weight, and stimulation difference at 40 °C recovery are very significant. In addition, the self-perception scale increased significantly after treatment at 35 °C and 40 °C.
Generally speaking, it is difficult for athletes to fully recover their muscles in a short time to reach the best competitive state. The effect of physical therapy such as cold-water bath on fatigue recovery has been studied. Likewise, muscle fatigue has been assessed through isometric force fall in response to MIVCs performed before and after different exercise protocols [44,45,46]. In the present study, the isometric exercise bout was able to induce a fatigue condition, as evidenced by the reduced isometric strength immediately after exercise (Table 4). Previous literature has studied various cooling methods (such as ice bag, CWI, and ice massage) to reduce skin temperature and promote fatigue recovery [47]. Although it was proved that CWI had a good response to muscle soreness, no dose–response relationship was observed for any outcome based on the application of the temperatures used [45], such as countermovement jumps, squat jumps, drop jumps with sledge apparatus, and sprints, but the experimental results did not find any benefit from using cold-water immersion compared to other recovery interventions [48]. Delextrat et al. compared the effects of intermittent cold-water immersion and massage on perceptual and performance markers of recovery by basketball players after competitive matches. The results found that massage is less useful than cold-water immersion in recovery [49]. There are also studies that combined multiple recovery interventions. A study compared five recovery methods and the results showed that, for short-term perceptual recovery, contrast water therapy (CWT) should be implemented and for short-term countermovement, power performance and active or control recovery is desirable [50]. Table 7 shows a comparative analysis of the effectiveness of various methods of fatigue recovery, including the research findings of this study. The low recovery efficiency and limited applicability of traditional recovery methods have led scholars to consider nanomaterials as a crucial avenue for research on fatigue recovery. Katsuura et al. and Nunes et al. found that wearing bioceramic clothing had no significant effect on fatigue recovery [51,52]. HE et al. compared massage therapy, ordinary far-infrared therapeutic apparatus, and far-infrared ceramic bead therapy [53]. The results showed that the recovery effect of ceramic beads was much better than the other two groups. Meanwhile, Soejima et al. suggest that WA on therapy employing an FIR dry sauna may be useful for treating chronic fatigue syndrome [54]. However, the application of WA in therapy has some limitations due to the harsh conditions of use. Materials with high far-infrared emissivity are quite promising in the modern medical care field, owing to their accelerating effects on blood circulation and metabolism [55]. For example, the far-infrared ceramic, invented by Professor Yang of Tsinghua University, has a significant infrared emission function, and the far-infrared emission rate of 2~18 μm at 60 °C is 88~92%, which is widely used in the training and recovery of professional athletes and the daily healthcare physiotherapy of ordinary people [38]. However, due to the complexity and low efficiency of the production process of far-infrared ceramics, it is difficult to apply it to the fatigue recovery of sports. Therefore, we employed far-infrared graphene material to explore its effect on the fatigue recovery of biceps brachii. Our study proved that the graphene FIR device could significantly alleviate fatigue after one-time exhaustion, and the degree of self-perceived fatigue was also significantly reduced, but other research reports have no significant changes [56]. Therefore, the results in this study revealed that we can promote fatigue recovery through the thermal effect and resonance effect of the FIR graphene heating device.
FIR has three main biological effects: radiation, vibration (or resonance), and thermal effect [58]. Radiation and resonance promote the oscillation of free ions, resulting in the denaturation of macromolecules such as proteins leading to an increase in the absorption of proteins in tissue frameworks [59]. Thermal effects induce angiogenesis and promote microcirculation by expanding blood and lymphatic vessels, activating Langerhans cells and macrophages [60]. At the same time, the Arginine-Modified Carbon Surface has great application in the development of electrochemical sensing, especially in the detection of dopamine [61]. The far-infrared graphene heating film can emit 8~15 μm infrared light, and the infrared emissivity is as high as 89%, which indicates a healthy infrared material. The biological effects of far-infrared rays have two aspects: far-infrared thermal biological effect and non-thermal biological effect. Compared with other healthcare materials, graphene films with these two kinds of biological effects on fatigue recovery have a positive effect. They have a good thermal effect and resonance effect, making the biomolecule at a higher resonance level, improving microcirculation, and promoting blood circulation and metabolism. When the infrared power is absorbed by the human body, it causes vibration in the myofibril molecule peptidoglycan, and in the case of low ATP, the biological compensation is transferred smoothly from one place to another. One study has proved that the temperature change caused by far-infrared radiation of graphene can be used to judge the strength of the human body’s “Yang Qi” [62]. Furthermore, graphene thermal therapy can reduce the maximum diameter and maximum cross-sectional area of benign thyroid nodules, which has a good clinical application prospect [63]. These effects suggest that the far-infrared graphene heating film has a good effect on fatigue relief, though its mechanism in exercise fatigue intervention recovery is still unclear.
Figure 4a shows the infrared thermal image obtained by the graphene heating device using the infrared thermal imaging instrument at 42 °C. The temperature scale indicates that the white color represents the material’s strongest infrared radiation, while the black color represents its weakest infrared radiation. We can see from the figure that the radiation of the graphene heating device is uniform, and the emissivity of the graphene heating film is 0.98, which is much higher than other materials (the galvanized glass is 0.05, the copper is 0.57, the sea salt is 0.91, and the far-infrared ceramic beads is 0.94) [40]. Meanwhile, there is no significant difference in the far-infrared spectra of the graphene heating device at different temperatures of 35 °C, 40 °C and 45 °C; only the intensity is different at 45 °C, as shown in Figure 4b. This indicates that the heating temperature has no obvious effect on the wavelength and intensity of the far infrared. Furthermore, the far-infrared emission material exhibits a consistent infrared wavelength range at three distinct temperatures, making it well-matched with blackbody radiation spectra. With an appropriate temperature, optimal thermal comfort can be maintained by the graphene heating device, which makes it an effective wearable device for promoting fatigue recovery.
The current study evaluated the impact of adding far-infrared hot compress supplementation to an exercise training program on 36 patients with biceps fatigue, who were randomized into four equal groups. Results showed that peak torque was significantly increased in groups B, C, and D post-treatment compared with the mean values of pre-treatment. In addition, a significant increase was recorded in the peak torque of group C compared with that of group A post-treatment. Compared with other traditional fatigue recovery methods, even other far-infrared technology, the graphene far-infrared device has a better effect on human local fatigue recovery. It is easier to carry and use, which is more conducive to application in competitive sports. In addition, the graphene heating device in this paper is more flexible when it has the same emission spectrum as other products, so it is more suitable for fatigue recovery in sports [18]. Therefore, this work proves that the graphene heating device has a promising application for human local fatigue recovery.

7. Conclusions

In this work, we report the preparation of a graphene far-infrared heating device and compare the effects of its intervention on the fatigue recovery of male college students after exhaustion. Compared with the natural recovery approach, a positive effect was found in terms of self-reported sensory manifestations in fatigue, as well as on the subjects’ maximum torque peak, suggesting that the graphene far-infrared heating device contributes to the recovery of the biceps muscle from exhaustion fatigue. In the future, we will upgrade our device to be rechargeable and portable, so that it can be applied to multiple conditions. In addition, we will apply the device to the muscles of the lower extremities to include the whole-body motion, and thus to sports that are not limited to the use of the upper limbs.

Author Contributions

Conceptualization, W.L. and Y.P.; Data curation, Z.Y.; Formal analysis, Z.Y.; Funding acquisition, W.L.; Investigation, Z.Y.; Methodology, X.J.; Project administration, W.L.; Supervision, W.L. and Y.P.; Validation, K.P.; Visualization, J.W.; Writing—original draft, Z.Y.; Writing—review and editing, Y.P. All authors have read and agreed to the published version of the manuscript.

Funding

This work is supported by the National Key R&D Program of China (No. 2016YFA0200200), National Natural Science Foundation of China (No. 52090030), Natural Science Foundation of Zhejiang Province (No. LTGY23E050002), Fujian Provincial Science and Technology Major Projects (No. 2018HZ0001-2), the Fundamental Research Funds for the Central Universities (No. 2021FZZX001-17), Zhijiang Youth Project of Zhejiang Provincial Philosophy and Social Science Planning (No. 22ZJQN14YB), the Key Research and Development Programme of Zhejiang (No. 2023C03196, No. 2022C03148), and Key Laboratory of Novel Adsorption and Separation Materials and Application Technology of Zhejiang Province (512301-I21502).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Lin, C.C.; Liu, X.M.; Peyton, K.; Wang, H.; Yang, W.C.; Lin, S.J.; Durante, W. Far infrared therapy inhibits vascular endothelial inflammation via the induction of heme oxygenase-1. Arterioscler. Thromb. Vasc. Biol. 2008, 28, 739–745. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Karvekar, S.; Abdollahi, M.; Rashedi, E. Smartphone-based human fatigue leveldetectionusing machine learning approaches. Ergonomics 2021, 64, 600–612. [Google Scholar] [CrossRef] [PubMed]
  3. Kellmann, M.; Bertollo, M.; Bosquet, L.; Brink, M.; Coutts, A.J.; Duffield, R.; Erlacher, D.; Halson, S.L.; Hecksteden, A.; Heidari, J.; et al. Recovery and Performance in Sport: Consensus Statement. Int. J. Sport. Physiol. Perform. 2018, 13, 240–245. [Google Scholar] [CrossRef] [Green Version]
  4. Dos Reis, F.A.; da Silva, B.A.K.; Laraia, E.M.S.; de Melo, R.M.; Silva, P.H.; Leal-Junior, E.C.P.; de Carvalho, P.D.T.C. Effects of pre- or post-exercise low-level laser therapy (830 nm) on skeletal muscle fatigue and biochemical markers of recovery in hHumans: Double-blind placebo-controlled trial. Photomed. Laser Surg. 2014, 32, 106–112. [Google Scholar] [CrossRef] [PubMed]
  5. Duffield, R.; Murphy, A.; Kellett, A.; Reid, M. Recovery from repeated on-court tennis sessions: Combining cold-water immersion, compression, and sleep interventions. Int. J. Sport. Physiol. Perform. 2014, 9, 273–282. [Google Scholar] [CrossRef]
  6. Ihsan, M.; Watson, G.; Abbiss, C.R. What are the physiological mechanisms for post-exercise cold water immersion in the recovery from prolonged endurance and intermittent exercise? Sport. Med. 2016, 46, 1095–1109. [Google Scholar] [CrossRef]
  7. Davis, H.L.; Alabed, S.; Chico, T.J.A. Effect of sports massage on performance and recovery: A systematic review and meta-analysis. BMJ Open Sport Exerc. Med. 2020, 6, e000614. [Google Scholar] [CrossRef]
  8. Ansari, N.N.; Naghdi, S.; Karimi-Zarchi, H.; Fakhari, Z.; Hasson, S. A Randomized controlled pilot study to investigate the effect of whole-body vibration on lower-extremity fatigue. J. Sport Rehabil. 2017, 26, 339–346. [Google Scholar] [CrossRef]
  9. Zhu, Y.; Sun, F.; Jia, C.; Zhao, T.; Mao, Y. A Stretchable and Self-Healing Hybrid Nano-Generator for Human Motion Monitoring. Nanomaterials 2022, 12, 104. [Google Scholar] [CrossRef]
  10. Zhao, T.; Fu, Y.; Sun, C.; Zhao, X.; Jiao, C.; Du, A.; Wang, Q.; Mao, Y.; Liu, B. Wearable biosensors for real-time sweat analysis and body motion capture based on stretchable fiber-based triboelectric nanogenerators. Biosens. Bioelectron. 2022, 205, 114115. [Google Scholar] [CrossRef]
  11. Kang, M.H.; Lee, G.J.; Lee, J.H.; Kim, M.S.; Yan, Z.; Jeong, J.W.; Jang, K.I.; Song, Y.M. Outdoor-Useable, Wireless/Battery-Free Patch-Type Tissue Oximeter with Radiative Cooling. Adv. Sci. 2021, 8, 2004885. [Google Scholar] [CrossRef] [PubMed]
  12. Byun, S.H.; Yun, J.H.; Heo, S.Y.; Shi, C.; Lee, G.J.; Agno, K.C.; Jang, K.I.; Xiao, J.; Song, Y.M.; Jeong, J.W. Self-Cooling Gallium-Based Transformative Electronics with a Radiative Cooler for Reliable Stiffness Tuning in Outdoor Use. Adv. Sci. 2022, 9, 2202549. [Google Scholar] [CrossRef] [PubMed]
  13. Liu, Y.; Li, P.; Wang, F.; Fang, W.; Xu, Z.; Gao, W.; Gao, C. Rapid roll-to-roll production of graphene films using intensive Joule heating. Carbon 2019, 155, 462–468. [Google Scholar] [CrossRef]
  14. Novoselov, K.S.; Fal’ko, V.I.; Colombo, L.; Gellert, P.R.; Schwab, M.G.; Kim, K. A roadmap for graphene. Nature 2012, 490, 192–200. [Google Scholar] [CrossRef] [PubMed]
  15. Raccichini, R.; Varzi, A.; Passerini, S.; Scrosati, B. The role of graphene for electrochemical energy storage. Nat. Mater. 2015, 14, 271–279. [Google Scholar] [CrossRef]
  16. Cao, Y.; Fatemi, V.; Fang, S.; Watanabe, K.; Taniguchi, T.; Kaxiras, E.; Jarillo-Herrero, P. Unconventional superconductivity in magic-angle graphene superlattices. Nature 2018, 556, 43–50. [Google Scholar] [CrossRef] [Green Version]
  17. Sorathiya, V.; Dave, V. Numerical study of a high negative refractive index based tunable metamaterial structure by graphene split ring resonator for far infrared frequency. Opt. Commun. 2020, 456, 124581. [Google Scholar] [CrossRef]
  18. Yu, T.; Hu, Y.; Feng, G.; Hu, K. A Graphene-Based Flexible Device as a Specific Far-Infrared Emitter for Noninvasive Tumor Therapy. Adv. Ther. 2020, 3, 1900195. [Google Scholar] [CrossRef]
  19. Kodesh, E.; Dar, G. The effect of kinesiotape on dynamic balance following muscle fatigue in individuals with chronic ankle instability. Res. Sport. Med. 2015, 23, 367–378. [Google Scholar] [CrossRef]
  20. Takeda, K.; Mani, H.; Hasegawa, N.; Sato, Y.; Tanaka, S.; Maejima, H.; Asaka, T. Adaptation effects in static postural control by providing simultaneous visual feedback of center of pressure and center of gravity. J. Physiol. Anthropol. 2017, 36, 31. [Google Scholar] [CrossRef] [Green Version]
  21. Gribble, P.A.; Hertel, J. Effect of hip and ankle muscle fatigue on unipedal postural control. J. Electromyogr. Kinesiol. 2004, 14, 641–646. [Google Scholar] [CrossRef] [PubMed]
  22. Gribble, P.A.; Hertel, J. Effectof Lower Extremity Muscle Fatigue on Postural Control. Med. Sci. Sport. Exerc. 2002, 34, S39. [Google Scholar] [CrossRef]
  23. Gribble, P.A.; Hertel, J. Effect of lower-extremity muscle fatigue on postural control. Arch. Phys. Med. Rehabil. 2004, 85, 589–592. [Google Scholar] [CrossRef] [PubMed]
  24. Johnston, R.D.; Gabbett, T.J.; Jenkins, D.G.; Hulin, B.T. Influence of physical qualities on post-match fatigue in rugby league players. J. Sci. Med. Sport 2015, 18, 209–213. [Google Scholar] [CrossRef]
  25. Lundin, T.M.; Feuerbach, J.W.; Grabiner, M.D. Effect of Plantar Flexor and Dorsiflexor Fatigue on Unilateral Postural Control. J. Appl. Biomech. 1993, 9, 191–201. [Google Scholar] [CrossRef] [Green Version]
  26. Hausswirth, C.; Louis, J.; Bieuzen, F.; Pournot, H.; Fournier, J.; Filliard, J.R.; Brisswalter, J. Effects of Whole-Body Cryotherapy vs. Far-Infrared vs. Passive Modalities on Recovery from Exercise-Induced Muscle Damage in Highly-Trained Runners. PLoS ONE 2011, 6, e27749. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  27. Hsieh, C.C.; Nosaka, K.; Chou, T.Y.; Hsu, S.T.; Chen, T.C. Effects of Far-Infrared Radiation-Lamp Therapy on Recovery from Simulated Soccer Match Running Activities in Elite Soccer Players. Int. J. Sport. Physiol. Perform. 2022, 17, 1432–1438. [Google Scholar] [CrossRef]
  28. Zhang, Y.; Peng, L.; Hu, K.; Gu, N. Stress Relaxation-Induced Colon Tumor Multicellular Spheroid Culture Based on Biomimetic Hydrogel for Nanoenzyme Ferroptosis Sensitization Evaluation. Adv. Healthc. Mater. 2023, 12, 2202009. [Google Scholar] [CrossRef]
  29. Ahmadi, S.; Gutierrez, G.L.; Uchida, M.C. Correlation between handgrip and isokinetic strength of shoulder muscles in elite sitting volleyball players. J. Bodyw. Mov. Ther. 2020, 24, 159–163. [Google Scholar] [CrossRef]
  30. Malavolta, E.A.; Cruz, D.G.; Gracitelli, M.E.C.; Assunção, J.H.; Andrade-Silva, F.B.; Andrusaitis, F.R.; Neto, A.A.F. Isokinetic evaluation of the shoulder and elbow after Latarjet procedure. Orthop. Traumatol. Surg. Res. 2020, 106, 1079–1082. [Google Scholar] [CrossRef]
  31. Felício, D.C.; Elias, J.; Queiroz, B.Z.D.; Diz, J.B.M.; Pereira, D.S.; Pereira, L.S.M. Knee extension strength and handgrip strength are important predictors of Timed Up and Go test performance among community-dwelling elderly women: A cross-sectional study. Sao Paulo Med. J. 2021, 139, 77–80. [Google Scholar] [CrossRef] [PubMed]
  32. Ünlüer, N.Ö.; Ateş, Y.; Balbaba, A.; Sücüllü Karadağ, Y. Investigation of non-motor symptoms, balance, muscle strength, and functional mobility in patients with parkinson’s disease. Somatosens. Mot. Res. 2021, 38, 20–26. [Google Scholar] [CrossRef] [PubMed]
  33. Badawy, M.M.; Allam, N.M. Impact of Adding Protein Supplementation to Exercise Training on Lean Body Mass and Muscle Strength in Burn Patients. J. Burn. Care Res. 2021, 42, 968–974. [Google Scholar] [CrossRef]
  34. Oppert, J.M.; Bellicha, A.; Roda, C.; Bouillot, J.L.; Torcivia, A.; Clement, K.; Poitou, C.; Ciangura, C. Resistance Training and Protein Supplementation Increase Strength After Bariatric Surgery: A Randomized Controlled Trial. Obesity 2018, 26, 1709–1720. [Google Scholar] [CrossRef] [Green Version]
  35. Salman, M.; Chu, X.; Huang, T.; Cai, S.; Yang, Q.; Dong, X.; Gopalsamy, K.; Gao, C. Functionalization of Wet-Spun Graphene Films Using Aminophenol Molecules for High Performance Supercapacitors. Mater. Chem. Front. 2018, 2, 2313–2319. [Google Scholar] [CrossRef]
  36. Li, P.; Yang, M.; Liu, Y.; Qin, H.; Liu, J.; Xu, Z.; Liu, Y.; Meng, F.; Lin, J.; Wang, F.; et al. Continuous Crystalline Graphene Papers with Gigapascal Strength by Intercalation Modulated Plasticization. Nat. Commun. 2020, 11, 2645. [Google Scholar] [CrossRef]
  37. Mak, K.F.; Ju, L.; Wang, F.; Heinz, T.F. Optical Spectroscopy of Graphene: From the FarInfrared to the Ultraviolet. Solid State Commun. 2012, 152, 1341–1349. [Google Scholar] [CrossRef]
  38. Vatansever, F.; Hamblin, M.R. Far infrared radiation (FIR): Its biological effects and medical applications. Photonics Lasers Med. 2012, 4, 255–266. [Google Scholar] [CrossRef] [Green Version]
  39. Inoue, S.; Takemoto, M.; Chishaki, A.; Ide, T.; Nishizaka, M.; Miyazono, M.; Sawatari, H.; Sunagawa, K. Leg heating using far infra-red radiation in patients with chronic heart failure acutely improves the hemodynamics, vascular endothelial function, and oxidative stress. Intern. Med. 2012, 51, 2263–2270. [Google Scholar] [CrossRef] [Green Version]
  40. Cao, Q.; Yang, J.; Mei, X.; Chen, X.; Hu, Y. Application Analysis of Far Infrared Ceramics in the Rehabilitation of Sports Injury. J. Mech. Med. Biol. 2013, 13, 1350028. [Google Scholar] [CrossRef]
  41. Lian, Y.; Yu, H.; Wang, M.; Yang, X.; Li, Z.; Yang, F.; Wang, Y.; Tai, H.; Liao, Y.; Wu, J.; et al. Multifunctional Wearable E-textile via Integrated Nanowire-Coated Fabrics. J. Mater. Chem. C 2020, 8, 8399–8409. [Google Scholar] [CrossRef]
  42. Gandevia, S.C. Spinal and Supraspinal Factors in Human Muscle Fatigue. Physiol. Rev. 2001, 81, 1725–1789. [Google Scholar] [CrossRef] [PubMed]
  43. Enoka, R.M.; Duchateau, J. Muscle fatigue: What, why and how it influences muscle function. J. Physiol. 2008, 586, 11–23. [Google Scholar] [CrossRef] [PubMed]
  44. Abaidia, A.E.; Lamblin, J.; Delecroix, B.; Leduc, C.; Mccall, A.; Nédélec, M.; Dawson, B.; Baquet, G.; Dupont, G. Recovery from Exercise-Induced Muscle Damage: Cold-Water Immersion Versus Whole-Body Cryotherapy. Int. J. Sport. Physiol. Perform. 2017, 12, 402–409. [Google Scholar] [CrossRef]
  45. Machado, A.F.; Almeida, A.C.; Micheletti, J.K.; Vanderlei, F.M.; Tribst, M.F.; Netto Junior, J.; Pastre, C.M. Dosages of Cold-Water Immersion Post Exercise on Functional and Clinical Responses: A Randomized Controlled Trial. Scand. J. Med. Sci. Sport. 2017, 27, 1356–1363. [Google Scholar] [CrossRef] [PubMed]
  46. Boccia, G.; Dardanello, D.; Zoppirolli, C.; Bortolan, L.; Cescon, C.; Schneebeli, A.; Vernillo, G.; Schena, F.; Rainoldi, A.; Pellegrini, B. Central and Peripheral Fatigue in Knee and Elbow Extensor Muscles After a Long-Distance Cross-Country Ski Race. Scand. J. Med. Sci. Sport. 2017, 27, 945–955. [Google Scholar] [CrossRef] [PubMed]
  47. Herrera, E.; Sandoval, M.C.; Camargo, D.M.; Salvini, T.F. Motor and Sensory Nerve Conduction Are Affected Differently by Ice Pack, Ice Massage, and Cold Water Immersion. Phys. Ther. 2010, 90, 581–591. [Google Scholar] [CrossRef] [Green Version]
  48. Kinugasa, T.; Kilding, A.E. A comparison of post-match recovery strategies in youth soccer players. J. Strength Cond. Res. 2009, 23, 1402–1407. [Google Scholar] [CrossRef] [Green Version]
  49. Delextrat, A.; Calleja-González, J.; Hippocrate, A.; Clarke, N.D. Effects of sports massage and intermittent cold-water immersion on recovery from matches by basketball players. J. Sport. Sci. 2013, 31, 11–19. [Google Scholar] [CrossRef]
  50. Crowther, F.; Sealey, R.; Crowe, M.; Edwards, A.; Halson, S. Influence of recovery strategies upon performance and perceptions following fatiguing exercise: A randomized controlled trial. BMC Sport. Sci. Med. Rehabil. 2017, 9, 25. [Google Scholar] [CrossRef] [Green Version]
  51. Katsuura, T.; Fukuda, S.; Okada, A.; Kikuchi, Y. Effect of ceramic-coated clothing on forearm blood flow during exercise in a cool environment. Ann. Physiol. Anthropol. 1989, 8, 53–55. [Google Scholar] [CrossRef] [PubMed]
  52. Nunes, R.F.; Cidral-Filho, F.J.; Flores, L.J.; Nakamura, F.Y.; Rodriguez, H.F.; Bobinski, F.; De Sousa, A.; Petronilho, F.; Danielski, L.G.; Martins, M.M.; et al. Effects of Far-Infrared Emitting Ceramic Materials on Recovery During 2-Week Preseason of Elite Futsal Players. J. Strength Cond. Res. 2020, 34, 235–248. [Google Scholar] [CrossRef] [PubMed]
  53. He, J.-W.; Yang, J.-L.; Wang, A.-L.; Cao, Q.-L. Quantitative Evaluation on Active Muscle, Passive Muscle Strength and PAR, AAR, TDPM Muscle Indicators by Far Infrared Ceramic Intervention. China Sport Sci. 2014, 34, 54–62. [Google Scholar]
  54. Soejima, Y.; Munemoto, T.; Masuda, A.; Uwatoko, Y.; Miyata, M.; Tei, C. Effects of Waon Therapy on Chronic Fatigue Syndrome: A Pilot Study. Intern. Med. 2015, 54, 333–338. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  55. Zhao, X.; Zhang, Y.; Xu, J.; Chen, D.; Chen, G. The synergistic effects study between metal oxides and graphene on far-infrared emission performance. SN Appl. Sci. 2020, 2, 610. [Google Scholar] [CrossRef] [Green Version]
  56. Ferreira-Junior, J.B.; Vieira, C.A.; Soares, S.R.S.; Guedes, R.; Junior, V.R.; Simoes, H.G.; Brown, L.E.; Bottaro, M. Effects of a Single Whole Body Cryotherapy (−110 °C) Bout on Neuromuscular Performance of the Elbow Flexors during Isokinetic Exercise. Int. J. Sport. Med. 2014, 35, 1179–1183. [Google Scholar] [CrossRef]
  57. Wang, X.; Yu, J.; Chen, P. Effects to resist sport fatigue based on the testing of the heart rate variability with the Gua Sha therapy of traditional Chinese medicine. J. Shanghai Univ. Sport 2021, 45, 76–83. [Google Scholar]
  58. Hwang, S.; Lee, D.H.; Lee, I.K.; Park, Y.M.; Jo, I. Far-infrared Radiation Inhibits Proliferation, Migration, and Angiogenesis of Human Umbilical Vein EndothelialCells by Suppressing Secretory Clusterin Levels. Cancer Lett. 2014, 346, 74–83. [Google Scholar] [CrossRef]
  59. Xia, L.; Cui, C.; Nicoli, F.; Al-Mousawi, A.; Campisi, C.C.; Lazzeri, D.; Liu, N.F.; Xie, B.; Li, K.; Zhang, Y. Far Infrared Radiation Therapy for Gynecological Cancer-Related Lymphedema Is an Effective and Oncologically Safe Treatment: A Randomized-Controlled Trial. Lymphat. Res. Biol. 2022, 20, 164–174. [Google Scholar] [CrossRef]
  60. Li, K.; Liu, N.; Yu, Z.; Sadigh, P.; Lazzeri, D.; Zhang, Y.X. Heating and Compression Bandage Treatment Is Effective for Chronic Lymphedema with Dermatolymphangioadenitis-A Case-Controlled Study. Lymphat. Res. Biol. 2016, 14, 233–239. [Google Scholar] [CrossRef]
  61. Revanappa, S.K.; Soni, I.; Siddalinganahalli, M.; Jayaprakash, G.K.; Flores-Moreno, R.; Bananakere Nanjegowda, C. A Fukui Analysis of an Arginine-Modified Carbon Surface for the Electrochemical Sensing of Dopamine. Materials 2022, 15, 6337. [Google Scholar] [CrossRef] [PubMed]
  62. Feng, G.P.; Hu, Y.M.; Chen, W.L. Development and Clinical Vertification of a Human Body “Yang Qi” Test Instrument. China Med. Device Inf. 2019, 25, 4. [Google Scholar]
  63. Ren, H.; Gao, H.; Li, Y.; Li, A.; Zhang, G.; Li, J. Therapeutic Effects of Graphene Thermal Therapy for Benign Thyroid Nodules. Chin. J. Med. Phys. 2019, 36, 5. [Google Scholar]
Figure 1. Flow chart of the graphene heating device prepared by the FFGS method.
Figure 1. Flow chart of the graphene heating device prepared by the FFGS method.
Bioengineering 10 00381 g001
Figure 2. Physical picture of the graphene heating device.
Figure 2. Physical picture of the graphene heating device.
Bioengineering 10 00381 g002
Figure 3. Wearing diagram of the FIR device.
Figure 3. Wearing diagram of the FIR device.
Bioengineering 10 00381 g003
Figure 4. (a) Infrared thermal image of graphene heating at 42 °C; (b) Far-infrared emission spectra of graphene heating device at different temperatures.
Figure 4. (a) Infrared thermal image of graphene heating at 42 °C; (b) Far-infrared emission spectra of graphene heating device at different temperatures.
Bioengineering 10 00381 g004
Table 1. General characteristics and grouping of participants.
Table 1. General characteristics and grouping of participants.
Group AGroup BGroup CGroup D
Control Group35 °C40 °C45 °C
Mean ± SDMean ± SDMean ± SDMean ± SD
n9999
Age (years)19.44 ± 1.1319.55 ± 1.3319.13 ± 1.1320.11 ± 1.36
Weight (kg)71.72 ± 4.8171.72 ± 5.8270.13 ± 6.2467.82 ± 3.71
Height (cm)178.44 ± 5.20180.7 ± 6.93177.75 ± 5.75177.67 ± 4.06
BMI (kg/m2)22.53 ± 1.3721.95 ± 1.3122.13 ± 1.2021.50 ± 1.31
The Group 35 °C, 40 °C and 45 °C means treatment with graphene device at temperature of 35 °C, 40 °C and 45 °C.
Table 2. Fatigue rating scale (RPE).
Table 2. Fatigue rating scale (RPE).
Self-PerceptionGrade
No sweat at all6–7
Very easily8
Easily9–11
Easy12–13
A little tired14–15
Tired16–17
Very tired18
Quite tired19
Burnout20
Table 3. Four index contrast of peak torque (Nm), average peak torque (Nm), etc., before exercise, after exercise/before treatment, and after treatment.
Table 3. Four index contrast of peak torque (Nm), average peak torque (Nm), etc., before exercise, after exercise/before treatment, and after treatment.
Peak Torque (Nm)Average Peak Torque (Nm)Average Peak Torque per Unit Weight (%)Coefficient of Variance (%)Stimulus (Nm)
Mean ± SDMean ± SDMean ± SDMean ± SDMean ± SD
Before exercise
A57.70 ± 9.5755.17 ± 9.2777.56 ± 14.894.52 ± 2.2611.02 ± 1.86
B53.80 ± 6.6051.48 ± 6.1772.04 ± 7.024.38 ± 3.0110.30 ± 1.23
C55.59 ± 4.6451.48 ± 6.1772.04 ± 7.025.90 ± 3.1310.53 ± 1.00
D58.88 ± 10.0156.17 ± 9.2783.21 ± 14.014.84 ± 2.2910.71 ± 0.93
After exercise/before treatment
A39.14 ± 7.2036.83 ± 7.0551.84 ± 11.646.36 ± 1.967.38 ± 1.42
B37.23 ± 5.4435.53 ± 5.3449.52 ± 4.585.04 ± 1.557.11 ± 1.07
C38.16 ± 3.4236.48 ± 3.3152.59 ± 3.405.51 ± 2.617.30 ± 0.67
D39.89 ± 6.2238.20 ± 6.3256.69 ± 10.134.49 ± 3.347.67 ± 1.26
After treatment
A43.56 ± 7.7841.18 ± 7.2757.93 ± 12.155.67 ± 2.438.23 ± 1.46
B47.93 ± 6.37 *45.89 ± 6.31 *64.11 ± 6.34 *4.64 ± 2.059.18 ± 1.26 *
C48.57 ± 4.62 **46.41 ± 3.57 **67.13 ± 6.32 **4.39 ± 3.559.30 ± 0.71 **
D49.88 ± 7.79 *47.59 ± 7.74 *70.50 ± 11.80 *5.07 ± 2.269.51 ± 1.56 *
*: p < 0.05, **: p < 0.001.
Table 4. The rank of immediate subjective feeling before and after treatment.
Table 4. The rank of immediate subjective feeling before and after treatment.
Subjective Feeling
BeforeA Little TiredTiredVery TiredQuite TiredBurnoutMean Rank
Group A1341017.33 ± 1.22
Group B1431017.22 ± 1.20
Group C2141117.22 ± 1.86
Group D1440017.11 ± 1.05
After treatmentA little tiredEasyEasilyVery easilyNo sweat at allMean rank
Group A6300013.67 ± 0.50 *
Group B2510112.11 ± 2.26 **
Group C2312110.89 ± 2.85 **
Group D1620012.22 ± 1.79 *
**: p < 0.05, *: p < 0.001. The number N means N people, for example, the number 1 of “Group A; A Little Tired” means there is only one person who felt a little tired in Group A.
Table 5. Average peak torque and fatigue level before and after treatment within each group.
Table 5. Average peak torque and fatigue level before and after treatment within each group.
Group AGroup BGroup CGroup D
Control Group35 °C40 °C45 °C
Mean ± SDMean ± SDMean ± SDMean ± SD
Average peak torque (Nm)
Before treatment36.83 ± 7.0535.53 ± 5.3436.48 ± 3.3138.20 ± 6.32
After treatment41.18 ± 7.2745.89 ± 6.3146.41 ± 3.5747.59 ± 7.74
MD (95% CI)−4.34 (−11.50: +2.81) −10.36 (−16.21: −4.50)−9.93 (−13.37: −6.49)−9.39 (−16.47: −2.31)
p = 0.216p = 0.002p = 0.000p = 0.013
Fatigue level
Before treatment17.33 ± 1.2217.22 ± 1.2017.22 ± 1.8617.11 ± 1.05
After treatment13.67 ± 0.5012.11 ± 2.2610.89 ± 2.8512.22 ± 1.79
MD (95% CI)+3.67 (+2.69: +4.64)+5.11 (+3.25: +6.97)+6.33 (+3.90: +8.77)+4.89 (+ 3.39: +6.38)
p = 0.000p = 0.000p = 0.000p = 0.000
Table 6. Comparison of average peak torque and fatigue level after treatment between the experimental group and the control group.
Table 6. Comparison of average peak torque and fatigue level after treatment between the experimental group and the control group.
Average Peak Torque (Nm)
A41.18 ± 7.27A41.18 ± 7.27A41.18 ± 7.27
B45.89 ± 6.31C46.41 ± 3.57D47.59 ± 7.74
MD (95% CI)−4.71 (−11.52: +2.09)MD (95% CI)−5.23 (−10.96: +0.49)MD (95% CI)−6.41 (−13.92: +1.10)
p = 0.162 p = 0.071 p = 0.089
Fatigue level
A13.67 ± 0.50A13.67 ± 0.50A13.67 ± 0.50
B12.11 ± 2.26C10.89 ± 2.85D12.22 ± 1.79
MD (95% CI)+1.56 (−0.08: +3.19)MD (95% CI)+2.78 (+0.73: +4.82)MD (95% CI)+1.44 (+0.05: +2.84)
p = 0.061 p = 0.011 p = 0.044
Table 7. Comparison of effects of different fatigue recovery methods.
Table 7. Comparison of effects of different fatigue recovery methods.
StudyParticipantsStudy DesignModeMain Results
Kinugasa et al. [48]28 healthy malesBefore the game, after the game, and 24 h after the gameCold-water immersionNo significant differences were found (p > 0.05).
Wang et al. [57]26 national men’s weightlifting team athletesRandomized controlled trialChinese medicine scrapingThe time domain index, frequency domain index, and PSQI in the scraping group were better than those in the control group.
Delextrat et al. [49].8 men and 8 women basketball playersRandomized controlled trialMassage, cold-water immersion or controlCWI improves jump performance, also is more useful than massage in recovery, especially in women.
Fiona et al. [50]34 recreationally active males Randomized pretest–post-test controlFive post exercise recovery strategies (CWI, CWT, ACT, CONT, COMB).CWT has better perception recovery, ACT and CONT have better jumping performance than CWI and COMB.
Katsuura et al. [51]7 healthy male studentsCross-over, control-innovative garments trialBioceramic t-shits and trousersVO2 had no significant change (p > 0.05).
Nunes et al. [52]20 elite futsal playersDouble-blind placebo-controlled trialBioceramic (BIO; n = 10); Placebo pants (pl; n = 10)No significant differences were found in 5-metre sprints in week 2.
He et al. [53]24 athletes with acute injuriesRandomized controlled trialMassage therapy, ordinary far-infrared therapeutic apparatus, far-infrared ceramic bead therapyAfter 3, 7, 14 days of treatment, the indexes of the ceramic bead group were better than those of the other two groups.
This work36 healthy male studentsRandomized controlled trialFar-infrared graphene heating deviceThe peak torque and stimulation difference at 40 °C recovery is very significant. The self-perception scale increased significantly after treatment at 35 °C and 40 °C.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Liu, W.; Jiang, X.; Yu, Z.; Pang, K.; Wang, J.; Peng, Y. Effects of a Graphene Heating Device on Fatigue Recovery of Biceps Brachii. Bioengineering 2023, 10, 381. https://doi.org/10.3390/bioengineering10030381

AMA Style

Liu W, Jiang X, Yu Z, Pang K, Wang J, Peng Y. Effects of a Graphene Heating Device on Fatigue Recovery of Biceps Brachii. Bioengineering. 2023; 10(3):381. https://doi.org/10.3390/bioengineering10030381

Chicago/Turabian Style

Liu, Wenming, Xiaohui Jiang, Zhiran Yu, Kai Pang, Jian Wang, and Yuxin Peng. 2023. "Effects of a Graphene Heating Device on Fatigue Recovery of Biceps Brachii" Bioengineering 10, no. 3: 381. https://doi.org/10.3390/bioengineering10030381

APA Style

Liu, W., Jiang, X., Yu, Z., Pang, K., Wang, J., & Peng, Y. (2023). Effects of a Graphene Heating Device on Fatigue Recovery of Biceps Brachii. Bioengineering, 10(3), 381. https://doi.org/10.3390/bioengineering10030381

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop