Numerical Analysis for Heat Transfer Augmentation in a Circular Tube Heat Exchanger Using a Triangular Perforated Y-Shaped Insert
Abstract
:1. Introduction
2. Geometry of Insert
3. Mathematical Calculations
4. Modelling and Grid Independence Test
4.1. Mathematical Modelling
4.2. Numerical Model
4.3. Grid Independence Test (GIT)
4.4. Model Validation
5. Results
5.1. Effect on Nu
5.2. Effect on f
5.3. Effect on TPF
6. Comparison with Previous Work
7. Conclusions
- The results show that increasing Re provides better heat transmission characteristics for higher perforated inserts along with decreasing the friction factor. Furthermore, a lower range of Reynolds number gives a higher value of TPF.
- The Nu varies between 60 to 210 with an increase in PI from 0% to 30% under the range of Reynolds number between 3000 and 21,000, whereas the friction factor varies between 0.05 and 0.51 with an increase in PI from 0% to 30% under the range of Reynolds number between 3000 and 21,000.
- The maximum TPF found is 3.25 at perforation index = 30% and Re = 3000. The enhancement in heat transmission is found 5.84 times better compared to the simple plain tube.
- It has also been observed from the study that this type of insert may be useful for industrial application because it significantly augments heat transmission by more than of five times and the thermal performance is enhanced by more than three times. The present study showed better heat transmission characteristics as compared to other research in the same range of Reynolds number.
Author Contributions
Funding
Conflicts of Interest
Nomenclature
A | Area of circular pipe (m2) |
Cp | Specific heat of air (Jkg−1 K−1) |
D | Test segment diameter (m) |
f | Friction factor for rough tube |
fs | Friction factor for simple plain tube |
h | Average convective heat transfer coefficient (W m−2 K−1) |
k | Thermal conductivity of air (Wm−1 k−1) |
L | Test section length (m) |
m | Air flow rate (kgs−1) |
Nu | Nusselt number |
Nus | Nusselt number for simple plain tube |
PA | Perforated area of insert (m2) |
Pr | Prandtl number |
Q | Heat flux (W) |
Qair | Heat carried by air (W) |
Qconv | Heat transfer by convection (W) |
Re | Reynolds number |
TA | Total area of Y-shaped insert (m2) |
Tfm | Fluid mean temperature (K) |
Ti | Air temperature at inlet (K) |
To | Air temperature at outlet (K) |
Twm | Wall mean temperature (K) |
v | Velocity of air (ms−1) |
ΔP | Pressure difference (between inlet and outlet of the test segment) (Pa) |
Abbreviations | |
TPF | Thermal performance factor |
PI | Perforation index (PA/TA) |
References
- Akcayoglu, A. Flow past confined delta-wing type vortex generators. Exp. Therm. Fluid Sci. 2011, 35, 112–120. [Google Scholar] [CrossRef]
- Bhuiya, M.M.K.; Sayema, A.S.M.; Islam, M.; Chowdhury, M.S.U.; Shahabuddine, M. Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts. Int. Commun. Heat Mass Transf. 2014, 50, 25–33. [Google Scholar] [CrossRef]
- Promvonge, P.; Koolnapadol, N.; Pimsarn, M.; Thianpong, C. Thermal performance enhancement in a heat exchanger tube fitted with inclined vortex rings. Appl. Therm. Eng. 2014, 62, 285–292. [Google Scholar] [CrossRef]
- Kumar, A.; Chamoli, S.; Kumar, M. Experimental investigation on thermal performance and fluid flow characteristics in heat exchanger tube with solid hollow circular disk inserts. Appl. Therm. Eng. 2016, 100, 227–236. [Google Scholar] [CrossRef]
- Zong, Y.; Bai, D.; Zhou, M.; Zhao, L. Numerical studies on heat transfer enhancement by hollow-cross disk for cracking coils. Chem. Eng. Process. Process Intensif. 2019, 135, 82–92. [Google Scholar] [CrossRef]
- Hameed, V.; Hussein, M. Effect of new type of enhancement on inside and outside surface of the tube side in single pass heat Exchanger. Appl. Therm. Eng. 2017, 122, 484–491. [Google Scholar] [CrossRef]
- Nagarajan, P.K.; Sivashanmugam, P. Heat Transfer Enhancement Studies in a Circular Tube Fitted with Right-Left Helical Inserts with Spacer, World Academy of Science, Engineering and Technology. Int. J. Mech. Mechatron. Eng. 2011, 5, 2091–2095. [Google Scholar]
- Gururatana, S.; Skullong, S. Experimental investigation of heat transfer in a tube heat exchanger with airfoil-shaped insert. Case Stud. Therm. Engin. 2019, 14, 100462. [Google Scholar] [CrossRef]
- Khoshvaght-Aliabadi, M.; Sartipzadeh, O.; Alizadeh, A. An experimental study on vortex-generator insert with different arrangements of delta-winglets. Energy 2015, 82, 629–639. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Promvonge, P. Influence of Double-sided Delta-wing Tape Insert with Alternate-axes on Flow and Heat Transfer Characteristics in a Heat Exchanger Tube, fluid flow and transport phenomena. Chin. J. Chem. Eng. 2011, 19, 410–423. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Promvonge, P. Performance assessment in a heat exchanger tube with alternate clockwise and counter-clockwise twisted-tape inserts. Int. J. Heat Mass Transf. 2010, 53, 1364–1372. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Thianpong, C.; Eiamsa-ard, P.; Promvonge, P. Convective heat transfer in a circular tube with short length twisted tape insert. Int. Commun. Heat Mass Transf. 2009, 36, 365–371. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Nuntadusit, C.; Promvonge, P. Effect of twin delta-winged twisted-tape on thermal performance of heat exchanger tube. Heat Transf. Eng. 2013, 34, 1278–1288. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Nanan, K.; Thianpong, C.; Eiamsa-ard, P. Thermal performance evaluation of heat exchanger tubes equipped with coupling twisted tapes. Exp. Heat Transf. 2013, 26, 413–430. [Google Scholar] [CrossRef]
- Nakhchi, M.E.; Esfahani, J.A. Numerical investigation of rectangular-cut twisted tape insert on performance improvement of heat exchangers. Int. J. Therm. Sci. 2019, 138, 75–83. [Google Scholar] [CrossRef]
- Rahimi, M.; Shabanian, S.R.; Alsairafi, A.A. Experimental and CFD studies on heat transfer and friction factor characteristics of a tube equipped with modified twisted tape inserts. Chem. Eng. Process. Process. Intensif. 2009, 48, 762–770. [Google Scholar] [CrossRef]
- Singh, S.; Negi, J.S.; Bisht, S.; Sah, H. Thermal performance and frictional losses study of solid hollow circular disc with rectangular wings in circular tube. Heat Mass Transf. 2019, 55, 2975–2986. [Google Scholar] [CrossRef]
- Kongkaitpaiboon, V.; Nanan, K.; Eiamsa-ard, S. Experimental investigation of convective heat transfer and pressure loss in a round tube fitted with circular-ring turbulators. Int. Comm. Heat Mass Transf. 2010, 37, 568–574. [Google Scholar] [CrossRef]
- Eiamsa-ard, S.; Kongkaitpaiboon, V.; Nanan, K. Thermohydraulics of turbulent flow through heat exchanger tubes fitted with circular-rings and twisted tapes. Chin. J. Chem. Eng. 2013, 21, 585–593. [Google Scholar] [CrossRef]
- Gautam, A.; Pandey, L.; Singh, S. Influence of perforated triple wing vortex generator on a turbulent flow through a circular tube. Heat and Mass Transfer. 2018, 54, 2009–2021. [Google Scholar] [CrossRef]
- Webb, R.L. Performance evaluation criteria for use of enhanced heat transfer surfaces in heat exchanger design. Int. J. Heat Mass Transf. 1981, 24, 715–726. [Google Scholar] [CrossRef]
Boundary Condition | Values |
---|---|
Air temperature at inlet (K) | 300 |
Inlet velocity (m/sec) | 5.18, 4.44, 3.706, 2.963, 2.22, 1.48, 0.7409 |
Heat flux (W/m2) | 1000 |
Ambient Pressure (atm) | 1 |
Density (kg/m3) | 1.225 |
Specific heat (J/kg−K) | 1006.53 |
Viscosity (kg/m−s) | 1.7894 × 10−5 |
Thermal conductivity (W/m−K) | 0.0242 |
Grid Number | Nu | f | ||
---|---|---|---|---|
50, 258 | 35.87 | - | 0.1486 | - |
98, 547 | 48.27 | 0.2569 | 0.1857 | 0.2001 |
3, 54, 782 | 60.12 | 0.1971 | 0.2106 | 0.1181 |
8, 84, 704 | 62.48 | 0.0378 | 0.2302 | 0.0852 |
15, 24, 877 | 62.49 | 0.0002 | 0.2413 | 0.0459 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Pandey, L.; Singh, S. Numerical Analysis for Heat Transfer Augmentation in a Circular Tube Heat Exchanger Using a Triangular Perforated Y-Shaped Insert. Fluids 2021, 6, 247. https://doi.org/10.3390/fluids6070247
Pandey L, Singh S. Numerical Analysis for Heat Transfer Augmentation in a Circular Tube Heat Exchanger Using a Triangular Perforated Y-Shaped Insert. Fluids. 2021; 6(7):247. https://doi.org/10.3390/fluids6070247
Chicago/Turabian StylePandey, Lokesh, and Satyendra Singh. 2021. "Numerical Analysis for Heat Transfer Augmentation in a Circular Tube Heat Exchanger Using a Triangular Perforated Y-Shaped Insert" Fluids 6, no. 7: 247. https://doi.org/10.3390/fluids6070247
APA StylePandey, L., & Singh, S. (2021). Numerical Analysis for Heat Transfer Augmentation in a Circular Tube Heat Exchanger Using a Triangular Perforated Y-Shaped Insert. Fluids, 6(7), 247. https://doi.org/10.3390/fluids6070247