Next Article in Journal
Occupational COVID-19 Prevention among Congolese Healthcare Workers: Knowledge, Practices, PPE Compliance, and Safety Imperatives
Next Article in Special Issue
Clinical and Preclinical Evidence for Adverse Neurodevelopment after Postnatal Zika Virus Infection
Previous Article in Journal
One Health and Neglected Tropical Diseases—Multisectoral Solutions to Endemic Challenges
Previous Article in Special Issue
Zika Virus Infection in Tourists Travelling to Thailand: Case Series Report
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Measurement of Head Circumference: Implications for Microcephaly Surveillance in Zika-Affected Areas

by
Emily W. Harville
1,*,
Van T. Tong
2,
Suzanne M. Gilboa
2,
Cynthia A. Moore
2,
Maria Luisa Cafferata
3,4,
Jackeline Alger
5,6,7,
Luz Gibbons
3,
Carolina Bustillo
8,9,
Allison Callejas
10,
Mario Castillo
10,
Jenny Fúnes
10,11,
Jorge García
5,6,
Gustavo Hernández
12,
Wendy López
5,6,
Carlos Ochoa
13,
Fátima Rico
11,14,
Heriberto Rodríguez
15,
Concepción Zúniga
6,16,
Alvaro Ciganda
4,
Candela Stella
3,
Giselle Tomasso
4 and
Pierre Buekens
1
add Show full author list remove Hide full author list
1
Department of Epidemiology, Tulane School of Public Health and Tropical Medicine, New Orleans, LA 70112, USA
2
Division of Birth Defects and Infant Disorders, National Center on Birth Defects and Developmental Disabilities, Centers for Disease Control and Prevention, Atlanta, GA 30333, USA
3
Instituto de Efectividad Clinica y Sanitaria, Buenos Aires 1414, Argentina
4
Unidad de Investigación Clínica y Epidemiológica, Montevideo 11600, Uruguay
5
Departamento de Laboratorio Clínico, Hospital Escuela, Tegucigalpa 11101, Honduras
6
Instituto de Enfermedades Infecciosas y Parasitología Antonio Vidal, Tegucigalpa 11101, Honduras
7
Unidad de Investigación Científica, Facultad de Ciencias Médicas, Universidad Nacional Autónoma de Honduras, Tegucigalpa 11101, Honduras
8
Departamento de Ginecología y Obstetricia, Hospital Escuela, Tegucigalpa 11101, Honduras
9
Departamento de Ginecología y Obstetricia, Facultad de Ciencias Médicas, UNAH, Tegucigalpa 11101, Honduras
10
Servicio de Neonatología, Departamento de Pediatría, Hospital Escuela, Tegucigalpa 11101, Honduras
11
Departamento de Pediatría, Facultad de Ciencias Médicas, Universidad Nacional Autónoma de Honduras, Tegucigalpa 11101, Honduras
12
Departamento de Pediatría, Hospital de Especialidades San Felipe, Tegucigalpa 11101, Honduras
13
Servicio de Maternidad, Hospital de Especialidades San Felipe, Tegucigalpa 11101, Honduras
14
Departamento de Pediatría, Hospital Escuela, Tegucigalpa 11101, Honduras
15
Sub-Dirección, Hospital de Especialidades San Felipe, Tegucigalpa 11101, Honduras
16
Departamento de Vigilancia de la Salud, Hospital Escuela, Tegucigalpa 11101, Honduras
*
Author to whom correspondence should be addressed.
Trop. Med. Infect. Dis. 2021, 6(1), 5; https://doi.org/10.3390/tropicalmed6010005
Submission received: 18 November 2020 / Revised: 14 December 2020 / Accepted: 18 December 2020 / Published: 29 December 2020
(This article belongs to the Special Issue Zika in Infants and Children)

Abstract

:
Worldwide recognition of the Zika virus outbreak in the Americas was triggered by an unexplained increase in the frequency of microcephaly. While severe microcephaly is readily identifiable at birth, diagnosing less severe cases requires comparison of head circumference (HC) measurement to a growth chart. We examine measured values of HC and digit preference in those values, and, by extension, the prevalence of microcephaly at birth in two data sources: a research study in Honduras and routine surveillance data in Uruguay. The Zika in Pregnancy in Honduras study enrolled pregnant women prenatally and followed them until delivery. Head circumference was measured with insertion tapes (SECA 212), and instructions including consistent placement of the tape and a request to record HC to the millimeter were posted where newborns were examined. Three indicators of microcephaly were calculated: (1) HC more than 2 standard deviations (SD) below the mean, (2) HC more than 3 SD below the mean (referred to as “severe microcephaly”) and (3) HC less than the 3rd percentile for sex and gestational age, using the INTERGROWTH-21st growth standards. We compared these results from those from a previous analysis of surveillance HC data from the Uruguay Perinatal Information System (Sistema Informático Perinatal (SIP). Valid data on HC were available on 579 infants, 578 with gestational age data. Nine babies (1.56%, 95% CI 0.71–2.93) had HC < 2SD, including two (0.35%, 95% CI 0.04–1.24) with HC < 3SD, and 11 (1.9%, 95% CI, 0.79–3.02) were below the 3rd percentile. The distribution of HC showed strong digit preference: 72% of measures were to the whole centimeter (cm) and 19% to the half-cm. Training and use of insertion tapes had little effect on digit preference, nor were overall HC curves sufficient to detect an increase in microcephaly during the Zika epidemic in Honduras. When microcephaly prevalence needs to be carefully analyzed, such as during the Zika epidemic, researchers may need to interpret HC data with caution.

1. Introduction

The major indicator that Zika virus (ZIKV) infection during pregnancy was affecting fetal brain development was an increase in microcephaly [1]. Severe microcephaly is readily identifiable at birth, but less severe cases require comparison of head circumference (HC) measurement to growth charts. There is no single clinical definition for microcephaly based on HC; widely-used definitions include HC 2 standard deviations (SDs) below the mean (3 SD for severe microcephaly) or below the 3rd percentile for sex and gestational age [2]. Percentile- and SD-based definitions are inherently problematic because, by definition, some proportion of the population will fall below the cut-off, even if completely healthy. However, even aside from this issue, the prevalence of microcephaly in surveillance data indicates that stricter definitions, or additional criteria, are generally used in clinical diagnosis. Population estimates of microcephaly were between 0.3 and 12 per 10,000 prior to the Zika epidemic [2,3,4,5,6,7], and in areas unaffected by Zika [8], substantially below the 15–300 per 10,000 that would be expected mathematically (3rd percentile or <3 SD below the mean). Comparing routinely collected data (the Brazilian Live Birth Information System) to those collected by trained research personnel suggested that microcephaly was substantially underreported, perhaps 90% of the time [3].
Accurate measurement of HC is challenging. A measuring tape must be placed precisely at the widest possible circumference of the head (the broadest part of the forehead above the eyebrow, above the ears and at the most prominent part of the back of the head [9]), and this can be difficult with a squirmy infant. INTERGROWTH, a global project to define standards for fetal and infant growth [10], recommends that two people assist in the measurement, one holding the infant on his or her lap, a procedure that is not always possible in a busy delivery room where the primary concern is likely to be assuring the health of mother and baby [11]. In addition, small degrees of tightening of the measuring tape can affect the measurement. One study showed that applying the tape tightly or loosely can induce a difference of 0.4 SD (or 0.4–0.5 cm) [12], while another found an inter-observer variability over 1 cm in 9% of the measurements [13]. Insertion tapes are regarded as more standardized and reliable than standard tape measures, and are used by the U.S. National Health and Nutrition Examination Survey (NHANES) [14,15], but the evidence that they improve measurement quality is limited. Studies have found parents can be trained to measure infant anthropometry, including HC, with good reliability and validity, although the error of measurement was 0.6 cm [16]. Since growth charts are to the millimeter, this still allows for substantial error.
Surveillance for microcephaly, generally or to assess trends in Zika-related illness, therefore becomes difficult. Multiple definitions of microcephaly make it challenging to compare trends over time or across countries [17]. Detection may be impacted by increased awareness due to the Zika epidemic [18,19]. The combination of measurement error and low prevalence means detecting a signal may be possible only in very severe outbreaks.
In this analysis, we examine HC measured values and digit preference in those values, and, by extension, the prevalence of microcephaly at birth in two groups. One is within a study in Honduras, where clinicians were part of a large-scale training and used insertion tape consistently for HC measures. We compare these data collected as part of our research study in Honduras to routine surveillance data from Uruguay [8].

2. Materials and Methods

We conducted a prospective pregnancy cohort study in Honduras in 2016 to study ZIKV infection: The Zika in Pregnancy in Honduras (ZIPH) study; details have been published previously [20]. We enrolled pregnant women at their first prenatal visit and followed them up until delivery. At the time of enrollment, women were interviewed to collect contact information for additional follow-up, sociodemographics, and symptoms of ZIKV infection. Care was taken to measure HC at birth accurately using best practices: insertion tapes (SECA 212) were provided, and instructions were posted in the room where newborns were measured (Figure 1), including instructions on the location of the tape relative to the child’s head and consistent placement of the markings and a specific request to record to the last whole millimeter. The tapes were donated to Neonatology Service at Hospital Escuela on 2 June 2016, and to Neonatology Service at Hospital San Felipe on 4 July 2016, three to seven weeks before the study started. Once the tapes were received, face-to-face training began. Starting in August 2016, INTERGROWTH-21st measures and training (online module on assessing newborn size by anthropometry) were promoted in the pediatrics department [21]. Initial dissemination was to pediatricians and neonatologists, followed by students. Health providers (medical students and residents) measuring the newborns were trained on a regular basis, including both face-to-face and online training, using the INTERGROWTH-21st materials. Supervising neonatologists and pediatricians monitored measurement during shifts and reviewed clinical charts on an ongoing basis. Starting in January 2017, certification was incorporated into the academic course for 7th year medical students (interns) and pediatrics residents. Between January and June 2017, 14 trainings were conducted with 192 students; over 95% of the students received the certification before beginning rotations. In addition, at each student rotation change (monthly or fortnightly) there was a verification of skills. For each newborn, the measurement was performed twice, at birth and at discharge or at 24 h. Only the birth measurement, which was part of the research protocol, is analyzed here.
We compared these results to those from a previous analysis of surveillance data in South America. We analyzed HC data from the Uruguay Perinatal Information System (Sistema Informático Perinatal (SIP) [8]. Briefly, this system includes data collected clinically as part of routine care, including the perinatal clinical record, delivery card, and neonatal hospitalization data [22]. The recommendation by the Ministry of Health is that clinicians use a flexible and inelastic tape to measure HC [23]. The HC variable allows for recording as centimeters with one decimal place. The Uruguay dataset included 261,330 live births, and for the purposes of this analysis, comparison was limited to plausible values, operationalized as those within 5 SD of the mean (n = 255,919, 99% of those with head circumference measures).
Microcephaly at birth was defined as HC more than 2SD below the mean, more than 3SD below the mean (severe microcephaly), or below the 3rd percentile for sex and gestational age (GA), using the INTERGROWTH-21st charts [8,10]. Confidence intervals for proportions were calculated using standard errors based on a binomial distribution. GA was estimated most commonly by last menstrual period (516/626, 82%); otherwise by ultrasound (90/626, 14%), clinical examination, or Capurro scores [24]. R and SAS 9.4 were used for data analysis. This study was reviewed and approved by the Tulane University and the Faculty of Medical Sciences, Universidad Nacional Autónoma de Honduras institutional review boards.

3. Results

In the ZIPH study, 667 women were enrolled in 2016 and 645 followed until the end of their pregnancy, including 600 livebirths, 36 early losses, and 9 stillbirths. Valid data on HC were available for 579 and for HC and GA on 578 (most of those missing data were delivered at other hospitals or their charts could not be located). Nine babies (1.56%, 95% CI 0.71–2.93) had HC more than 2SD below the mean, including two (0.35%, 95% CI 0.04–1.24) with HC more than 3SD below the mean, and 11 (1.9%, 95% CI, 0.79–3.02) below the 3rd percentile (Table 1).
The distribution of HC (Figure 2, Table 2) showed strong digit preference, despite the training and use of insertion tapes for HC measurement. 72% of recorded measures were to the whole cm, with an additional 19% to the half-cm. No recorded measures were to 0.1, and only a small number to other mm. The two cases of severe microcephaly associated with ZIKV infection were not sufficient to meaningfully increase the overall rate of microcephaly in the Honduras study during the ZIKV outbreak (Table 1).
When compared to a previous analysis using surveillance data in Uruguay [8], mean and median HC were slightly lower (Figure 3). Mean z-score relative to INTERGROWTH-21st standards in the ZIPH cohort was 0.55 and median z-score was 0.53, while in the Uruguay data, the mean z-score was 0.77 and the median was 0.84.

4. Discussion

In this study, training and use of insertion tapes had little effect on digit preference, nor were overall HC curves sufficient to detect an increase in microcephaly during the Zika epidemic in Honduras. We also compared this with a previous analysis we had done on routine HC measurements in a non-Zika-affected country. Despite the different countries, clinical settings, and degree of focus on and training in HC measurement, several results were similar across the two settings. When microcephaly was considered by SD definitions, proportions in each group were lower than mathematically expected (similar to the Uruguay analysis), though the calculated confidence intervals for the proportions were consistent with those percentiles. Mean and median HC were slightly lower in Honduras than in Uruguay, but the left tail of the distribution was not noticeably thicker (Figure 3). This is despite the fact that 2016 marked the peak for Zika infection in Honduras, while the epidemic never spread to Uruguay. We also found similar results in the two cohorts in terms of digit preference, with the vast majority being measured to the cm or half-cm (Table 2). It appears the provision of and training on SECA 212 tapes had little effect on the tendency to measure to the whole centimeter, although rounding to the half-centimeter was diminished a little (19% in Honduras compared to 25% in Uruguay). A study of measurement protocols in children under 5 in Atlanta, Georgia also found digit preference for HC, though much less to decimal places 0 and 5 [25]. However, even in the rigorously standardized INTERGROWTH study, technical error of measurement was still 0.3−0.4 cm [26]. Our study is limited by the small sample size and the lack of pre-training measures.
Simulations indicate that surveillance data are generally insufficient to estimate the gestational-age-specific risk of microcephaly, especially given possible changes in reporting that might be caused by an epidemic [27,28]. Birth defect surveillance data from Colombia did indicate a peak in microcephaly (based on diagnosis code) corresponding with the Zika epidemic; however, very large numbers would be needed to detect the observed differences in prevalence (13 cases per 10,000 livebirths during the outbreak, vs. 8 per 10,000 before and 11 per 10,000 after) [29]. In addition, percentile-based definitions produce a high degree of false positives when compared to truly pathological cases; simulation studies under realistic scenarios estimate <5% positive predictive value [27].
Several studies show that, regardless of efforts to standardize, measurement of HC is not necessarily accurate or precise. A 2018 survey of U.S. nurses showed that a minority of respondents were recording HC to the nearest 0.1 cm, while a majority measured 0.5 cm or larger increments [30]. A Chinese study found that test-retest reliability for HC was good, with correlations > 0.95, but the mean interobserver difference was 0.4 cm [31]. Studies of measurement of growth in children indicate that even basic measurements like height are often inaccurate, although training can improve them [32]. Measurement protocols also differ even when rigorously standardized—the U.S. Centers for Disease Control and Prevention’s recommendation for the Zika epidemic was to measure three times and take the largest measurement [9], while NHANES requires only a single measure [15]. Because of the limited reliability, other methods of assessing HC have been sought, including digital calipers that limit stretching [33], and use of biparietal diameter instead of circumference [34]; however, limited availability and required maintenance of appropriate instruments, as well as lack of sex and GA standards for biparietal diameter in most populations might be challenges for widespread adoption of these methods. As training on the SECA tapes was not successful in correcting issues identified with the measurement of head circumference in hospital settings, it is probable that precise head circumference measurement in the delivery room is an unrealistic goal. Our findings, showing some improvement in diminishing half-centimeter measurements, indicate that there might be the need for additional or regular refresher training. Other tools and procedures, such as visual reminders in the form of additional posters in the nursery or other parts of the wards, short instructional videos, and periodic review of head circumference measurements by nursery staff to look for these patterns, could also be helpful. Ultimately, the development of technology that is less prone to user variation is needed.
We conclude that researchers may want to interpret HC data with caution. Under circumstances when microcephaly prevalence needs to be carefully analyzed and trends determined, such as the Zika epidemic, researchers might consider developing and evaluating new measurement methods.

Author Contributions

Conceptualization, V.T.T., S.M.G., C.A.M., and P.B.; data curation, M.L.C., L.G., C.S., and G.T.; formal analysis, E.W.H. and L.G.; funding acquisition, J.A. and P.B.; investigation, M.L.C., C.B., A.C. (Allison Callejas), M.C., J.F., J.G., G.H., W.L., C.O., F.R., H.R., C.Z., A.C. (Alvaro Ciganda), and G.T.; methodology, W.L. and A.C. (Alvaro Ciganda); project administration, J.A.; supervision, V.T.T., S.M.G., C.A.M., C.B., J.F., J.G., W.L., and C.Z.; validation, J.A., G.H., C.O., F.R., H.R., C.Z., and A.C. (Alvaro Ciganda); writing—original draft, E.W.H.; writing—review and editing, V.T.T., S.M.G., C.A.M., M.L.C., C.S., and P.B. All authors have read and agreed to the published version of the manuscript.

Funding

This study was funded by Vysnova Partners (SC-2018-3045-TU).

Conflicts of Interest

The authors declare no conflict of interest. The findings and conclusions in this report are those of the authors and do not necessarily represent the official position of the Centers for Disease Control and Prevention.

References

  1. Teixeira, M.G.; da Conceicao, N.C.M.; de Oliveira, W.K.; Nunes, M.L.; Rodrigues, L.C. The Epidemic of Zika Virus-Related Microcephaly in Brazil: Detection, Control, Etiology, and Future Scenarios. Am. J. Public Health 2016, 106, 601–605. [Google Scholar] [CrossRef]
  2. DeSilva, M.; Munoz, F.M.; Sell, E.; Marshall, H.; Tse Kawai, A.; Kachikis, A.; Heath, P.; Klein, N.P.; Oleske, J.M.; Jehan, F.; et al. Congenital microcephaly: Case definition & guidelines for data collection, analysis, and presentation of safety data after maternal immunisation. Vaccine 2017, 35, 6472–6482. [Google Scholar] [CrossRef]
  3. Silva, A.A.; Barbieri, M.A.; Alves, M.T.; Carvalho, C.A.; Batista, R.F.; Ribeiro, M.R.; Lamy-Filho, F.; Lamy, Z.C.; Cardoso, V.C.; Cavalli, R.C.; et al. Prevalence and Risk Factors for Microcephaly at Birth in Brazil in 2010. Pediatrics 2018, 141. [Google Scholar] [CrossRef] [Green Version]
  4. Graham, K.A.; Fox, D.J.; Talati, A.; Pantea, C.; Brady, L.; Carter, S.L.; Friedenberg, E.; Vora, N.M.; Browne, M.L.; Lee, C.T. Prevalence and Clinical Attributes of Congenital Microcephaly-New York, 2013–2015. MMWR Morb. Mortal. Wkly. Rep. 2017, 66, 125–129. [Google Scholar] [CrossRef]
  5. Morris, J.K.; Rankin, J.; Garne, E.; Loane, M.; Greenlees, R.; Addor, M.C.; Arriola, L.; Barisic, I.; Bergman, J.E.; Csaky-Szunyogh, M.; et al. Prevalence of microcephaly in Europe: Population based study. BMJ 2016, 354, i4721. [Google Scholar] [CrossRef] [Green Version]
  6. Candelo, E.; Caicedo, G.; Feinstein, M.M.; Pachajoa, H. Microcephaly in Colombia before the Zika outbreak: A systematic literature review. Biomedica 2018, 38, 127–134. [Google Scholar] [CrossRef]
  7. Orioli, I.M.; Dolk, H.; Lopez-Camelo, J.S.; Mattos, D.; Poletta, F.A.; Dutra, M.G.; Carvalho, F.M.; Castilla, E.E. Prevalence and clinical profile of microcephaly in South America pre-Zika, 2005–2014: Prevalence and case-control study. BMJ 2017, 359, j5018. [Google Scholar] [CrossRef] [Green Version]
  8. Harville, E.W.; Buekens, P.M.; Cafferata, M.L.; Gilboa, S.; Tomasso, G.; Tong, V. Measurement error, microcephaly prevalence and implications for Zika: An analysis of Uruguay perinatal data. Arch. Dis. Child. 2020, 105, 428–432. [Google Scholar] [CrossRef]
  9. Centers for Disease Control and Prevention. Measuring Head Circumference. Available online: https://www.cdc.gov/zika/pdfs/microcephaly_measuring.pdf (accessed on 12 October 2019).
  10. Villar, J.; Cheikh Ismail, L.; Victora, C.G.; Ohuma, E.O.; Bertino, E.; Altman, D.G.; Lambert, A.; Papageorghiou, A.T.; Carvalho, M.; Jaffer, Y.A.; et al. International standards for newborn weight, length, and head circumference by gestational age and sex: The Newborn Cross-Sectional Study of the INTERGROWTH-21st Project. Lancet 2014, 384, 857–868. [Google Scholar] [CrossRef]
  11. International Fetal and Newborn Growth Consortium. INTERGROWTH-21st International Fetal and Newborn Growth Standards for the 21st Century Anthropometry Handbook; University of Oxford: Oxford, UK, 2012. [Google Scholar]
  12. Wright, C.M.; Bremner, M.; Lip, S.; Symonds, J.D. Does measurement technique explain the mismatch between European head size and WHO charts? Arch. Dis. Child. 2017, 102, 639–643. [Google Scholar] [CrossRef]
  13. Bartram, J.L.; Rigby, A.S.; Baxter, P.S. The “Lasso-o” tape: Stretchability and observer variability in head circumference measurement. Arch. Dis. Child. 2005, 90, 820–821. [Google Scholar] [CrossRef]
  14. Zerfas, A.J. The insertion tape: A new circumference tape for use in nutritional assessment. Am. J. Clin. Nutr. 1975, 28, 782–787. [Google Scholar] [CrossRef]
  15. Centers for Disease Control and Prevention. National Health and Nutrition Examination Series (NHANES) Anthropometry Proced. Man; Centers for Disease Control and Prevention: Atlanta, GA, USA, 2009; p. 39. [Google Scholar]
  16. Bradley, J.L.; Brown, J.E.; Himes, J.H. Reliability and validity of parental measurements of infant size. Am. J. Hum. Biol. 2001, 13, 275–279. [Google Scholar] [CrossRef]
  17. Magalhaes-Barbosa, M.C.; Prata-Barbosa, A.; Robaina, J.R.; Raymundo, C.E.; Lima-Setta, F.; Cunha, A. New trends of the microcephaly and Zika virus outbreak in Brazil, July 2016–December 2016. Travel Med. Infect. Dis. 2017, 16, 52–57. [Google Scholar] [CrossRef]
  18. Bragazzi, N.L.; Alicino, C.; Trucchi, C.; Paganino, C.; Barberis, I.; Martini, M.; Sticchi, L.; Trinka, E.; Brigo, F.; Ansaldi, F.; et al. Global reaction to the recent outbreaks of Zika virus: Insights from a Big Data analysis. PLoS ONE 2017, 12, e0185263. [Google Scholar] [CrossRef] [Green Version]
  19. Duarte Dos Santos, C.N.; Goldenberg, S. Zika Virus and Microcephaly: Challenges for a Long-Term Agenda. Trends Parasitol 2016, 32, 508–511. [Google Scholar] [CrossRef] [Green Version]
  20. Buekens, P.; Alger, J.; Althabe, F.; Bergel, E.; Berrueta, A.M.; Bustillo, C.; Cafferata, M.L.; Harville, E.; Rosales, K.; Wesson, D.M.; et al. Zika virus infection in pregnant women in Honduras: Study protocol. Reprod. Health 2016, 13, 82. [Google Scholar] [CrossRef] [Green Version]
  21. Research Capacity Network. INTERGROWTH-21st. Available online: https://rede.tghn.org/training/intergrowth-21-training-rede/ (accessed on 14 October 2020).
  22. Latin American Center of Perinatology Women and Reproductive Health. Sistema Informatico Perinatal. Available online: https://paho.org/clap/index.php?option=com_content&view=article&id=84:sistema-informatico-perinatal&Itemid=242&lang=en (accessed on 6 July 2018).
  23. Ministerio de Desarrollo Social (MIDES). Evaluacion del Crecimiento del Nino y la Nina Desde el Nacimiento Hasta los 5 Anos de Edad [Evaluation of Growth of the Boy and Girl, from 5 to Five Years of Age]. 2016. Available online: https://www.gub.uy/ministerio-salud-publica/sites/ministerio-salud-publica/files/documentos/publicaciones/Guia%20evaluaci%C3%B3n%20crecimiento%200%20a%205%20a%C3%B1os.pdf (accessed on 18 November 2020).
  24. Capurro, H.; Konichezky, S.; Fonseca, D.; Caldeyro-Barcia, R. A simplified method for diagnosis of gestational age in the newborn infant. J. Pediatr. 1978, 93, 120–122. [Google Scholar] [CrossRef]
  25. Conkle, J.; Ramakrishnan, U.; Flores-Ayala, R.; Suchdev, P.S.; Martorell, R. Improving the quality of child anthropometry: Manual anthropometry in the Body Imaging for Nutritional Assessment Study (BINA). PLoS ONE 2017, 12, e0189332. [Google Scholar] [CrossRef]
  26. Cheikh Ismail, L.; Knight, H.E.; Ohuma, E.O.; Hoch, L.; Chumlea, W.C. Anthropometric standardisation and quality control protocols for the construction of new, international, fetal and newborn growth standards: The INTERGROWTH-21st Project. BJOG 2013, 120 (Suppl. 2), 48–55. [Google Scholar] [CrossRef] [Green Version]
  27. Kalmin, M.M.; Gower, E.W.; Stringer, E.M.; Bowman, N.M.; Rogawski McQuade, E.T.; Westreich, D. Misclassification in defining and diagnosing microcephaly. Paediatr. Perinat. Epidemiol. 2019, 33, 286–290. [Google Scholar] [CrossRef]
  28. Hay, J.A.; Nouvellet, P.; Donnelly, C.A.; Riley, S. Potential inconsistencies in Zika surveillance data and our understanding of risk during pregnancy. PLoS Negl. Trop. Dis. 2018, 12, e0006991. [Google Scholar] [CrossRef] [Green Version]
  29. Ospina, M.L.; Tong, V.T.; Gonzalez, M.; Valencia, D.; Mercado, M.; Gilboa, S.M.; Rodriguez, A.J.; Tinker, S.C.; Rico, A.; Winfield, C.M.; et al. Zika Virus Disease and Pregnancy Outcomes in Colombia. N. Engl. J. Med. 2020, 383, 537–545. [Google Scholar] [CrossRef]
  30. Foote, J.M.; Hanrahan, K.; Mulder, P.J.; Nielsen, A.K.; Perkhounkova, Y.; Hein, M.; Saeidzadeh, S.; McCarthy, A.M. Growth Measurement Practices from a National Survey of Neonatal Nurses. J. Pediatr. Nurs. 2020, 52, 10–17. [Google Scholar] [CrossRef]
  31. Yin, H.; Dai, Y.; Li, H.; Xie, X.; Ren, H. The test-re-test reliability of routine infant anthropometry at primary care hospitals in Chongqing, PR China. Ann. Hum. Biol. 2013, 40, 309–317. [Google Scholar] [CrossRef]
  32. Lipman, T.H.; Hench, K.D.; Benyi, T.; Delaune, J.; Gilluly, K.A.; Johnson, L.; Johnson, M.G.; McKnight-Menci, H.; Shorkey, D.; Shults, J.; et al. A multicentre randomised controlled trial of an intervention to improve the accuracy of linear growth measurement. Arch. Dis. Child. 2004, 89, 342–346. [Google Scholar] [CrossRef] [Green Version]
  33. Gerver, W.J.; Gidding, C.; van Amstel, M.; Vles, J.S. A new device to measure short-term growth of head circumference in newborn infants. Eur. J. Pediatr. 1990, 149, 768–770. [Google Scholar] [CrossRef]
  34. Tirosh, E.; Weinger, M.A.; Berger, A.; Cohen, A. Biparietal diameter: An alternative measure of head growth in the low-birthweight infant. J. Med. Eng. Technol. 1992, 16, 79–81. [Google Scholar] [CrossRef]
Figure 1. Instructions for use of SECA 212 insertion tapes posted in the room where newborns were measured, Zika in Pregnancy in Honduras (ZIPH) (2016). Hospital Escuela, Tegucigalpa, Honduras. Sign translates, “Always use the Seca tape to measure head circumference.”
Figure 1. Instructions for use of SECA 212 insertion tapes posted in the room where newborns were measured, Zika in Pregnancy in Honduras (ZIPH) (2016). Hospital Escuela, Tegucigalpa, Honduras. Sign translates, “Always use the Seca tape to measure head circumference.”
Tropicalmed 06 00005 g001aTropicalmed 06 00005 g001b
Figure 2. Distribution of head circumference at birth in the Zika in Pregnancy in Honduras (ZIPH) cohort (n = 579).
Figure 2. Distribution of head circumference at birth in the Zika in Pregnancy in Honduras (ZIPH) cohort (n = 579).
Tropicalmed 06 00005 g002
Figure 3. Distribution of head circumference in the Zika in Pregnancy in Honduras cohort (2016) and the Uruguay SIP surveillance system (2010–2015).
Figure 3. Distribution of head circumference in the Zika in Pregnancy in Honduras cohort (2016) and the Uruguay SIP surveillance system (2010–2015).
Tropicalmed 06 00005 g003
Table 1. Description of the Zika in Pregnancy in Honduras (ZIPH) cohort, 2016.
Table 1. Description of the Zika in Pregnancy in Honduras (ZIPH) cohort, 2016.
All Women
n%
Maternal Variables
Maternal age in years (n = 667)
12–19 19829.7%
20–3440460.6%
35 or higher659.8%
Years of education and range (n = 667) 9 (6–12)
Infant Variables
Head circumference at birth (n = 578)
mean in cm (SD) 34.1 (1.62)
median in cm (IQR) 34.0 (33.0–35.0)
mode in cm, range 34.0 (26–43)
HC more than 2SD below the mean *91.56, 95% CI 0.71–2.93 **
HC more than 3SD below the mean *20.35, 95% CI 0.04–1.24
HC < 3rd percentile *111.90, 95% CI 0.79–3.02
HC, head circumference; SD, standard deviation; IQR, interquartile range. * For sex and gestational age. ** calculated using standard errors based on binomial distribution.
Table 2. Distribution of head circumference measures for the Zika in Pregnancy in Honduras Cohort (2016) and the Uruguay Perinatal Information System (Sistema Informático Perinatal, SIP) Surveillance System (2010−2015).
Table 2. Distribution of head circumference measures for the Zika in Pregnancy in Honduras Cohort (2016) and the Uruguay Perinatal Information System (Sistema Informático Perinatal, SIP) Surveillance System (2010−2015).
ZIPH CohortUruguay SIP
Last Digit (Tenths Place)N%N%
041972.4188,10873.5
0.100.01020.0
0.2101.74440.2
0.381.44620.2
0.450.94350.2
0.511219.365,19625.5
0.6152.63040.1
0.771.22910.1
0.820.34320.2
0.910.21450.1
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Harville, E.W.; Tong, V.T.; Gilboa, S.M.; Moore, C.A.; Cafferata, M.L.; Alger, J.; Gibbons, L.; Bustillo, C.; Callejas, A.; Castillo, M.; et al. Measurement of Head Circumference: Implications for Microcephaly Surveillance in Zika-Affected Areas. Trop. Med. Infect. Dis. 2021, 6, 5. https://doi.org/10.3390/tropicalmed6010005

AMA Style

Harville EW, Tong VT, Gilboa SM, Moore CA, Cafferata ML, Alger J, Gibbons L, Bustillo C, Callejas A, Castillo M, et al. Measurement of Head Circumference: Implications for Microcephaly Surveillance in Zika-Affected Areas. Tropical Medicine and Infectious Disease. 2021; 6(1):5. https://doi.org/10.3390/tropicalmed6010005

Chicago/Turabian Style

Harville, Emily W., Van T. Tong, Suzanne M. Gilboa, Cynthia A. Moore, Maria Luisa Cafferata, Jackeline Alger, Luz Gibbons, Carolina Bustillo, Allison Callejas, Mario Castillo, and et al. 2021. "Measurement of Head Circumference: Implications for Microcephaly Surveillance in Zika-Affected Areas" Tropical Medicine and Infectious Disease 6, no. 1: 5. https://doi.org/10.3390/tropicalmed6010005

APA Style

Harville, E. W., Tong, V. T., Gilboa, S. M., Moore, C. A., Cafferata, M. L., Alger, J., Gibbons, L., Bustillo, C., Callejas, A., Castillo, M., Fúnes, J., García, J., Hernández, G., López, W., Ochoa, C., Rico, F., Rodríguez, H., Zúniga, C., Ciganda, A., ... Buekens, P. (2021). Measurement of Head Circumference: Implications for Microcephaly Surveillance in Zika-Affected Areas. Tropical Medicine and Infectious Disease, 6(1), 5. https://doi.org/10.3390/tropicalmed6010005

Article Metrics

Back to TopTop