1. Introduction
Continuous-time analog filter design has gained widespread attention and holds substantial significance, mainly due to its extensive range of practical applications. The reason for this is the existence of a universal filter structure that can simultaneously provide the outputs of low-pass (LP), high-pass (HP), and all-pass (AP) filters from a one-filter structure. Universal filter structures, incorporating both LP and HP designs that constitute fundamental components of high-order active filter structures, are widely recognized for their crucial roles in an array of essential fields. These fields are biosensor systems, electrocardiogram devices, phase-sensitive detectors, sensor-based instruments, control systems, and data communication networks, thereby establishing universal filter structures as key components [
1,
2].
Progress in analog active filter components has been remarkable, initiated by the introduction of first-generation current conveyors (CCI) in 1968 [
3], closely followed by the emergence of second-generation current conveyors (CCII) in 1970 [
4], attributed to the pioneering work of Sedra and Smith. The development continued with the introduction of third-generation current conveyors (CCIII) in 1995 [
5], and shortly thereafter, second-generation current-controlled conveyors (CCCII) were proposed to the literature by Fabre [
6]. This innovative progression has led to the adoption of numerous current-mode (CM) and voltage-mode (VM) filter circuits, all built upon the foundations of the CCII active filter component [
7,
8]. Filters are essential components in signal processing systems, impacting key areas like signal modulation, demodulation, amplification, and noise reduction. In contemporary applications, fractional-order calculus has gained prominence as a favored filtering technique [
9].
The establishment of fractional-order calculus occurred many years ago, but its current prominence is attributed to its enhanced capacity for the improved design and modeling of real-world objects, various natural phenomena, and systems [
10]. It has found uses in diverse disciplines such as control theory [
11], bioengineering [
12], biochemistry [
13], medicine [
14], material science [
15], agriculture [
16], PV modeling [
17], robotics [
18], oscillators [
19], and electronic filters [
2,
3,
4,
5,
6,
7,
8,
9,
10,
11,
12,
13,
14,
15,
16,
17,
18,
19,
20,
21,
22]. Consequently, fractional-order calculus has evolved into a multidisciplinary pursuit, supporting various fields and establishing the foundation for numerous innovative applications. In particular, the application of fractional-order calculus applied to analog electronic filters has surged in popularity and established itself as a significant research area in the literature. This arises from the fact that the frequency responses of fractional-order filters are contingent not only on circuit components but also on fractional-order parameters. The fractional-order parameter introduces an additional degree of freedom, enabling precise control over stopband attenuation and the transition slope from the passband to the stopband. As a result, fractional-order filters provide a versatile design approach, meeting all the necessary filter specifications. To transform analog integer-order filters into fractional-order filters, fractional-order passive components known as fractional-order capacitors (FOCs) are required. FOCs are not yet commercially available, but fractional-order filter approximation methods found in the existing literature are utilized to construct them in filter circuits theoretically. To develop these approximation methods, appropriately configured RC networks are employed in studies [
21,
23].
There are very few studies in the literature that involve the design of analog one-fractional order filters using the CCII active filter component [
2,
3,
4,
5,
6,
7,
8,
9,
10,
11,
12,
13,
14,
15,
16,
17,
18,
19,
20]. The first of these studies was conducted by Radwan et al. (2008) [
20]. By applying fractional-order calculus to traditional integer-order filters, one-fractional order LP, HP, AP, and band-pass (BP) filters’ outputs were separately obtained. However, all of these filter structures are constructed with passive elements and are VM filters. Another study conducted by Herencsar (2020) [
24] involved designing one-fractional order AP filters employing generalized first-kind five-port current conveyors. Although the designed filters are CM filters, it was observed that they provide only an AP filter responses. Kapoulea’s doctoral dissertation in 2022 [
2] presents the transfer functions and outputs of one-fractional order LP and HP filters, thereby contributing to the literature in this area. However, filter outputs are theoretically generated using only transfer functions for one frequency.
The adjustment for pitch in human speech perception, driven by its non-linear characteristics, necessitates an effective solution. This requirement is effectively met by employing shelving filters. Shelving filters are categorized into two primary groups: LP shelving filters and HP shelving filters. LP shelving filters, in contrast to traditional LP filters, do not entirely eliminate out-of-band frequencies but, instead, provide flexibility for amplification or attenuation according to the researcher’s choice. They effectively transmit higher frequencies, as well as those exceeding the predetermined cut-off frequency. HP shelving filters, on the other hand, allow lower frequencies, including those below the predetermined cut-off frequency, to pass through while granting the researcher the capability to amplify or attenuate higher frequencies according to their preferences. This unique characteristic stands out as one of the most notable advantages of shelving filters [
25].
The first mention of fractional-order shelving filters was made by Fierro et al. (2019) [
26]. According to this study, shelving filters were designed to provide a better listening experience in the Equal Loudness Level Contours (ELLC) standard created by ISO226:2003 [
27]. The results of the study showed that the frequency magnitude response slope of the sound is less than 20 dB/decade. It was decided that shelving filters should be designed as fractional-order filters to achieve a slope of less than 20 dB/decade. This is because the frequency magnitude response slope of fractional-order filters is
dB/decade. In this context,
represents the filter order, and it falls within the range
. The study conducted by Fierro et al. (2019) [
26] also encouraged researchers to design shelving filters as fractional-order in the literature for a better utilization of sound frequencies.
To the best of the authors’ knowledge, the existing literature comprises only four studies on fractional-order analog shelving filters [
28,
29]. The pioneering work by Kapoulea et al. (2020) [
28] introduced two fractional-order shelving filters, encompassing LP and HP designs. Employing Operational Transconductance Amplifiers (OTA) as active filter elements, these VM filters have an electronic tunability property through the CFE method. However, the circuits included a notable number of active filter elements. Subsequent research by Kapoulea et al. in 2021 [
30] extended this exploration, presenting two distinct filter design approaches. The first focused on VM, LP, and HP fractional-order shelving filters, utilizing the classic fractional-order bilinear transfer function. By contrast, the second approach aimed to create VM power-law shelving filters by transforming the integer-order transfer function into its corresponding power-law representation. Both designs utilized a single second-generation voltage conveyor (VCII) as the active filter element, approximated through the Oustaloup approximation tool and designed with a Foster type-I RC network. A comparative analysis between classic fractional-order designs and power-law designs revealed that the latter exhibited a reduction in the number of passive elements, thanks to their inherent fractional-order characteristics. When configured in a CM filter, power-law designs might require fewer passive elements, offering a simpler circuit architecture. Consequently, the adoption of power law designs became unnecessary, enabling the creation of circuits with fewer passive components.
A subsequent exploration of this subject was conducted by Pagidas et al. in 2022 [
29]. In their research, fractional-order LP and HP shelving filters were designed, with operational amplifiers (op-amp) serving as the primary active filter components. The study introduced a generalized framework for the development of fractional-order shelving filters. In this innovative approach, the filters acquired fractional-order attributes by employing the Oustaloup approximation technique, ensuring that the transfer functions’ ratio involved two impedances. This strategic approach aimed to streamline the circuit complexity, as discussed in a previous study by Kapoulea et al. (2021) [
30]. Additionally, the fractional-order shelving filters designed in Pagidas et al.’s study required a minimum number of passive elements due to their ratio-based fractional-order nature. However, when shelving filters are designed as CM systems, they inherently include a minimum number of passive elements. Consequently, shelving filters can be engineered with fewer passive components by means of direct and conventional fractional-order computations.
The most recent contribution to this topic was presented by Sen et al. (2023) [
25]. CM, LP, and HP fractional-order shelving filters were designed using a modified current feedback operational amplifier (MCFOA) as an active filter element. The filters in Sen et al.’s study were designed as CM filters, containing a minimum number of grounded passive elements, resulting in a simple design procedure and minimal circuit complexity. The presented shelving filter circuits were made fractional-order using the Oustaloup approximation tool and a properly configured Foster type-I RC network. Additionally, Sen et al.’s study was the first to use the MCFOA active filter element to design fractional-order shelving filters. Two input signals were applied to each of the created filters. All of the fractional-order analog shelving filters mentioned in this literature are summarized in
Table 1.
This study is structured into two primary sections: CM one-fractional order filters, and fractional-order shelving filters. Notably, these filters were not developed as separate filter structures; rather, they are integrated into a single filter framework. In practical terms, a single input signal is applied to the designed filter circuit, resulting in the generation of multiple-output signals (ten outputs). The filter circuit simultaneously produces one-fractional order LP, HP, and AP filter outputs with both positive and negative gains, in addition to fractional-order shelving filter outputs with both positive and negative gains. Despite the generation of numerous output signals, the presented filter circuit maintains a straightforward design. The filter’s circuitry exclusively utilizes three multi-output second-generation current-controlled conveyors (MO-CCCII) and grounded passive components. To incorporate fractional-order features into the designed filter, the Oustaloup approximation method was chosen for its remarkable capacity to mold filter response attributes. The Oustaloup approximation tool was constructed through appropriately configured RC networks. In this study, the Foster type-I RC network was employed due to its inclusion of a minimal number of capacitors and resistors, as well as its reasonable sensitivity despite containing passive elements.
In this study, the presented filter circuit was specifically designed for its outstanding attributes, including its wide bandwidth, minimal power consumption, high linearity, broad dynamic range, straightforward circuit structure, and adaptability for integrated design, rendering it well-suited for applications in CM filters. Due to its compatibility with CM filters, the CCCII active filter building block was preferred. The CCCII element demonstrated better filter characteristics, including linearity, signal bandwidth, and dynamic range, in comparison to op-amp-based filters [
22]. To further enhance these characteristics, the CCCII element was implemented using bipolar junction transistors (BJTs), as they are more suitable for CM and low-power/voltage applications [
25]. Furthermore, it was noted that adjustments to the values of passive components within the circuit could alter the cut-off frequency and gain of the designed filter circuit. The filter presented circuit underwent simulation using the PSpice program to validate its behavior. The simulation outcomes confirmed that the cut-off frequency of the designed filter circuit was measured at 1 kHz. From this cut-off frequency, it became apparent that the outputs of the fractional-order filter could serve in control systems and sensor applications, whereas the outputs of the fractional-order shelving filter could be applicable in acoustic applications. The designed filter circuit, being CM-compatible and containing a minimal number of grounded passive components, offers benefits such as fewer components, reduced space requirements, lower costs, and lower power consumption. Consequently, it can better meet the system requirements in the mentioned application areas. Under these conditions, the filter circuit designed to simultaneously provide both classical and fractional-order filters with multiple outputs (ten outputs) is, to the best of the authors’ knowledge, a first in the literature.
In the second section of the paper, the methodologies employed are discussed. First, the block structure, definition equations, and internal circuitry of the MO-CCCII active filter element are presented. Following this, one-fractional order filters are explained, and towards the end of the section, fractional-order cascaded filters are detailed. The third section provides the circuit diagram of the filter designed using the MO-CCCII active filter element, including the transfer functions of one-fractional order filters and fractional-order cascaded filters. In the fourth section, simulation results of the designed filter circuit are demonstrated through PSpice program simulations. Finally, the fifth and sixth sections of the paper address the discussions and present the conclusions of the study.
4. Simulation Results of the Designed Filter Circuit Using the MO-CCCII Element
The filter circuit, incorporating the multiple-output (ten outputs) CM and MO-CCCII active element as shown in
Figure 3, underwent simulation using the PSpice program. Through the simulation, the transfer functions of the filter were validated, with the cut-off frequency recorded at 1 kHz. The filter circuit, which is capable of simultaneously delivering both integer-order (first-order LP, HP, and AP) and fractional-order filter outputs, features a straightforward circuit structure. Comprising only four grounded resistors and two fractional-order capacitors, the circuit features
k
and
k
. For this specific filter circuit, exclusively the negative gain outputs of the fractional-order shelving filters were derived, with
k
and
k
. In this context,
and
symbolize the fractional-order capacitors, with their values determined as 5
at a 1 kHz cut-off frequency, as illustrated in
Figure 3.
A fifth-order Oustaloup approximation tool was utilized to generate fractional-order capacitors. This methodology, demonstrated through the Foster type-I RC network depicted in
Figure 4, was employed to determine the fractional-order (
) of the designed filter at values of 0.7, 0.8, and 0.9. The calculation of the passive elements in the Foster type-I RC network corresponding to each fractional order was carried out using Equation (
32). To conform to the more readily available E96 series outlined in IEC 60063, the calculated values of the passive elements underwent rounding. This adjustment enhances the feasibility of implementing the designed filter in real-world applications.
Table 2 provides the values of the passive elements in the Foster type-I RC network, calculated according to Equation (
32) and rounded to comply with the E96 series. Furthermore, gain and phase simulations for the Foster type-I RC networks were conducted for all fractional orders, as depicted in
Figure 5. The simulation results indicate that the bandwidths of the Foster type-I RC networks are suitable for both acoustic and control-system applications.
The filter circuit was implemented using three MO-CCCII active elements, which were derived by duplicating the
-terminals through the use of current mirrors from the CCCII active element. This contributed to reducing the number of active elements in the circuit. Furthermore, to enhance its suitability for CM studies and low-power/voltage applications, the MO-CCCII active element was designed with a BJT-based configuration (see
Figure 2). The internal structure of the MO-CCCII element, as shown in
Figure 2, incorporates the DC voltage sources
V and the DC current sources
13
A. PNP (PR100N)- and NPN (NR100N)-type BJT transistors were employed in the internal arrangement of the MO-CCCII, with their parameter values outlined in
Table 3.
The first phase of the study involves presenting the gain responses of the one-fractional order LP and HP filters, as shown in
Figure 6. Phase simulations were conducted to observe both the positive and negative gain outputs of the one-fractional order LP and HP filters simultaneously, and the simulation outcome are presented in
Figure 7.
Another output from the designed filter is the one-fractional order AP filter with positive gain. The gain response of this filter is given in
Figure 8. Similar to other types of one-fractional order filters, a phase simulation was conducted to observe both positive and negative gain outputs of the one-fractional order AP filter simultaneously, and the simulation result is presented in
Figure 9.
The tunability of the cut-off frequencies and gains for the one-fractional order filter outputs was achieved by adjusting the values of the passive elements within the designed filter (see
Figure 3). This modification provides an additional advantage to the designed filter. To illustrate the filter’s tunability, the positive-gain one-fractional order LP output (
) was examined. By adjusting only the value of the
element while keeping other passive elements constant, changes were observed exclusively in the cut-off frequency. These changes in the cut-off frequency are shown in
Figure 10. Similarly, adjusting only the value of the
element while keeping other passive elements unchanged resulted in variations in the filter’s gain. The variations in the filter gain are presented in
Figure 11.
The second phase of the study presented the gain responses of both positive and negative LP and HP fractional-order shelving filter outputs. The gains and phase responses of both the positive and negative outputs of the LP fractional-order shelving filter are shown in
Figure 12.
The gains and phase responses of both the positive and negative outputs of the HP fractional-order shelving filter are shown in
Figure 13.
Table 4 presents the key characteristics in the frequency behaviors for the LP and HP fractional-order shelving filter outputs from the designed filter. The values given in parentheses in
Table 4 present the theoretical gain and phase responses derived from Equations (
15) and (
16). Conversely, the values outside the parentheses denote the gain and phase responses acquired through simulation.
Figure 14 presents both the theoretical and simulated gain and phase responses of the LP and HP fractional-order shelving filters. In this figure, the solid lines represent the simulated gain and phase responses, while the dashed lines correspond to the theoretical responses.
The frequency response of the fractional-order shelving filter outputs is tunable through adjustments to the passive elements’ values within the filter design (see
Figure 3), providing an additional advantage to the filter. To highlight the filter’s adjustability, we specifically examined the positive-gain fractional-order LP shelving filter output (
). Altering only the
element’s value while keeping other passive element values constant revealed changes solely in the cut-off frequency. These modifications in the cut-off frequency are illustrated in the gain and phase graph in
Figure 15.
The total harmonic distortion (THD (%)) values were obtained through the positive-gain fractional-order LP shelving filter output (
) given in
Figure 3. To calculate the THD (%) values, the DC current sources (
) in the filter structure were set to 13
A, and the cut-off frequency (
) of the filter was set to 1 kHz. Then, different sinusoidal signals in the range of 0.1
A to 500
A were applied to the input of the designed filter, with the input frequency matching the cut-off frequency. It was observed that the corresponding THD (%) values were smaller than 0.8. The graph showing the THD (%) values is presented in
Figure 16.
The dynamic range, a pivotal concept in filter design, outlines the relationship between the largest input signal accommodated by the filter and the smallest input signal necessary for its operation, as expressed in Equation (
33). With the THD (%) values obtained from the designed filter, input signals spanning from 0.1
A to 500
A can be applied to the filter. As a result, the dynamic range of the designed filter exceeds 60 dB, indicating its provision of an extensive dynamic range. Additionally, both power consumption and noise analysis were conducted for the designed filter. The simulation results indicate that the power consumption is less than 1 mW for a single 2.5 V supply. The total output noise of the designed filter was measured as
.
The Monte Carlo analysis tool within the PSpice program was employed to examine the sensitivity of the internal values of the BJT transistor to variations in passive circuit elements. The analysis comprised 100 runs, targeting the positive-gain low-pass fractional-order (
) shelving filter output. Initially, a Monte Carlo analysis with a 20% tolerance was performed for the saturation currents (
), early voltages (
), and internal resistances (
,
, and
) of the BJT. The analysis results, including gain and phase graphs, are presented in
Figure 17. Comparing the standard deviation values (0.408 dB and
) with the nominal values provided in
Table 4 (2.98 dB and −
), it is evident that the designed filter circuit exhibits reasonable sensitivity characteristics.
Second, the BJT parameter values were reinstated for the positive-gain fractional-order LP filter (
) output. Subsequently, to observe the sensitivity of the shelving gain (
G) outlined in Equation (
28) to variations in the filter, a Monte Carlo analysis was conducted by adjusting only the resistance values of
,
, and
with a 10% tolerance.
Figure 18 displays the results of the analysis, presenting the gain and phase graphs. Comparing the standard deviation values (0.29 dB and
) with the nominal values in
Table 4 (2.98 dB and −
), it is evident that the designed filter circuit exhibits reasonable sensitivity.
5. Discussion
In this study, a CM analog filter designed with the MO-CCCII active element presented an innovative approach to active filter design by applying a fractional-order calculation. By using current mirrors to duplicate the -terminals of the CCCII active element, a multi-output MO-CCCII (seven outputs) element was obtained. The outputs of the filter circuit with the MO-CCCII element can be duplicated without using any additional circuit according to the designer’s needs. This reduces the count of active elements in the filter structure and diminishes the necessity for passive elements in the circuit design.
Filtering designed as fractional-order introduces a significant change to filters. This change is a key characteristic of fractional-order filters. Fractional-order filters provide an extra degree of freedom to the filter with the
value, allowing for sharper control of the transition slope from the passband to the stopband, thus providing flexibility to the design process. The filter circuit given in
Figure 3 was simulated using the PSpice program. While the filter circuit provides both positive and negative gain, one-fractional order LP, HP, and AP filter outputs, as well as LP and HP fractional-order shelving filter outputs (ten outputs), were verified, highlighting the advantages of the filter. Although the designed filter circuit can provide multiple filter outputs simultaneously, it possesses superior features such as simplicity and suitability for integrated design, as introduced by the CM study. The gain and phase of the filter were found to be modifiable based on the values of the passive elements included, as observed in the simulation results. This advantageous situation demonstrated the versatility of the filter in electronic applications.
The sensitivity of the filter to parameter mismatch and the sensitivity to changes in the values of passive elements in the circuit were measured using the Monte-Carlo analysis tool. The analysis result shows that despite the presence of BJTs and many passive elements in the internal structure of the filter, it exhibited reasonable sensitivity and confirmed the reliability of the filter under practical conditions.
Upon evaluating the overall performance of the filter, it was found to be low-power, low-noise, low-THD (%), and with a wide dynamic range. These features make it a suitable candidate for acoustic and control applications in practical scenarios. The evaluation of the filter’s general performance showed promising results for fractional-order active filter designs with the MO-CCCII active element. The filter’s CM, as well as its ability to provide multiple filter outputs simultaneously, its simple circuit structure, and its tunability contribute to this promising path. These features offer opportunities for further exploration and development in electronic systems.
In conclusion, the fractional-order filter circuit designed with the MO-CCCII active element presents a promising path for fractional-order active filter designs. The filter’s CM, as well as its ability to provide multiple filter outputs simultaneously, its simple circuit structure, and its tunability make it a suitable candidate for practical applications in the field of electronic systems. The combination of these features opens up opportunities for more discoveries and advancements in electronic systems.