1. Introduction
In conventional magnetron sputtering, energetic electrons are effectively confined due to the presence of transverse magnetic field lines above the target surface. As a consequence, both the ionization rate of the sputtering gas and the sputtering rate of the target material are significantly increased [
1].
This is not the case for ferromagnetic metals, e.g., nickel, iron, and cobalt. A ferromagnetic target performs as a magnetic field conductor, completing the magnetic circuit of the magnetron. As a result, most of the magnetic field lines above the target are absent. Therefore, the conventional design of the magnetron is not suitable for the deposition of ferromagnetic films.
Since ferromagnetic thin films are widely used in industrial applications [
2,
3], a number of magnetron configurations have been proposed that deposit at an acceptable deposition rate [
4,
5,
6,
7]. However, the planar Penning trapping configuration [
8] is of particular interest here. In this configuration, a circular plate and a concentric ring with a ferromagnetic target are used to form an annular narrow gap. The gap allows some leaking of magnetic field lines and provides the transverse component of the field. The anode cavity below the gap is also introduced to prevent sputtering of the target backing plate.
Recently, the inverted gapped-target magnetron was developed as a device for ferromagnetic film deposition, providing a means to produce good quality, crack-free nickel films [
9]. This is mainly due to the ion bombardment with energy of about 200 eV during the film growth. However, the ion density (as implied from the measured discharge current) is rather low when operated in direct current (DC) mode. In addition, the majority of the energetic ions are ionized from the sputtering gas, e.g., argon ions.
High power impulse magnetron sputtering (HiPIMS) is now a well-established technique to generate large ion fluxes of sputtered particles [
10]. By applying pulses of high discharge power to a magnetron target, a considerable amount of sputtered species can be ionized by electron-impact ionization in the dense plasma.
The main purpose of the present work was to apply the HiPIMS technique to the inverted magnetron in order to enhance the density of the energetic ions of both gas and metal species. This requires the further modification of a HiPIMS power supply to drive the inverted magnetron with positive pulsed voltages. The discharge characteristics of the magnetron operated in the HiPIMS mode were investigated and are discussed. In addition, the relative deposition rates and ion flux for a number of process conditions were measured using a quartz crystal microbalance (QCM) and a planar electrical probe, respectively.
2. Materials and Methods
The structure of the inverted magnetron has been provided in detail elsewhere [
9]. However, a schematic diagram showing the arrangement of the magnetron used in the present work is shown in
Figure 1a. The magnetron mainly consisted of a 410-grade stainless-steel anode and a gapped-nickel cathode. The anode was biased to the positive driven-voltage, while the cathode was grounded. The gapped-nickel cathode consisted of two concentric pieces, i.e., a central disk and a ring. The diameter of the central disk was about 31 mm, while the inner and the outer diameter of the ring target was 37 mm and 70 mm, respectively. The thickness of both the central disk and the ring was about 6 mm. Using this target configuration, a complete circular gap was formed with a width of 3 mm. It is important to note that the central disk was actually supported by a target holder held at the axis of the magnetron. However, the holder of the central disk is not shown in
Figure 1a for simplicity. The permanent magnets embedded in the anode were employed to generate the magnetic field for the electron confinement at the cathode gap. As a result, the plasma was able to be generated around the cathode gap, enabling the sputtering of cathode material.
Power was supplied to the plasma using a DC pre-ionizer coupled to a HiPIMS unit, in principle, similar to that used in a previous report [
11], but with opposite polarity. The DC unit was used to ignite and sustain the background plasma, while the main discharge power was delivered by the HiPIMS unit. The width (
w) and repetition rate (
f) of the HiPIMS pulse can be adjusted in the range of 20–400 µs and 10–500 Hz, respectively. However, a pulse repetition rate of 30 Hz and a pulse width of 300 µs were selected as the HiPIMS pulse parameters for the present work.
The inverted magnetron was installed in an in-house coating system, as shown in
Figure 1b. A cylindrical vacuum chamber was evacuated to a base pressure of 5 × 10
−4 Pa by a diffusion pump and a rotary pump. Argon as the sputtering gas was introduced to the chamber via a mass flow controller (4850, Brooks Instrument, Hatfield, PA, country) at a flow rate between 10 sccm and 50 sccm. As a result, the process pressure between 0.3 Pa and 13 Pa could be maintained. In a routine operation, the background plasma is initially ignited at a rather high pressure using the positive DC unit. Then, the argon flow rate is reduced to establish a designed process pressure before applying positive HiPIMS pulses to the magnetron. Using this approach, HiPIMS plasma can be generated during the pulse at pressures down to about 1 Pa.
The waveforms of the discharge voltage (Vd) and current (Id) were measured using a high voltage probe (10076B, Agilent, Santa Clara, CA, USA) and a non-invasive current monitor (101, Pearson Electronics, Palo Alto, CA, USA), respectively. A digital oscilloscope (DSO1002A, Agilent, Santa Clara, CA, USA) were employed for the monitoring and recording of the Vd and Id waveforms. The waveforms of the discharge power (Pd) can be obtained from Pd = VdId.
To investigate the effect of the average discharge power on the particle fluxes arriving at a typical substrate position, probing was performed using: (1) a planar electrical probe to determine the ion flux, and (2) a QCM to determine the sputtered particle arrival rates. The planar probe had a circular stainless steel exposed surface of 16 mm diameter and was grounded to obtain a saturation current (Ip), monitored by a current probe (2877, Pearson Electronics, Palo Alto, CA, USA). Hence, the ion fluxes arriving to the probe could be easily determined. The deposition rate and thickness of the formed nickel films was determined in the vicinity of the flux probe using the QCM devices (STM-2XM, Inficon, Badragaz, Switzerland), both 45 mm from the cathode gap.
3. Results
The discharge waveforms for a process pressure of 1 Pa are shown in
Figure 2. In general, the waveforms were almost the same as those of a conventional HiPIMS except for the polarity. In the case of the inverted configuration, the discharge signals were all positive with respect to the ground.
The background plasma,
PDC, required a low DC power of about 70 W with a sustained voltage and current of about 230 V and 0.3 A, respectively. The discharge changed to high power mode when a positive pulse from the HiPIMS unit was applied to the anode. Using the initial HiPIMS voltage of 540 V at
t = 0 µs, a discharge current of up to a peak (
Ipeak) of 13 A developed during the on-time phase (
t = 0–300 µs), yielding a peak discharge power (
Ppeak) of about 5 kW (see
Figure 2a–c). It is worth mentioning that the
Vd sharply dropped to below 400 V, corresponding to the high discharge current drawn to the magnetron. The discharge current waveform generally indicates the variation of the plasma density [
12]. The discharge current jumped from ~0.3 A in DC mode to ~13 A in HiPIMS mode. The density of the plasma in DC mode has been reported to be approximately 0.6 × 10
16 m
−3 [
9]. Therefore, a plasma density during the HiPIMS pulses in the order of 3 × 10
16 m
−3 could be expected.
The high discharge current during the HiPIMS pulse agreed well with the probe current determining the ion fluxes at the probe position. The current drawn to the grounded probe is plotted in
Figure 3. In the high power mode, an I
p with a peak value of 0.06 A was obtained at the end of the pulse (t ~ 300 µs). It is worth mentioning that a positive current of several hundreds of microamperes was observed even in the DC mode. The positive probe current observed during both the DC and HiPIMS mode indicated that the ion flux arriving to the grounded probe was significantly larger than the electron flux.
It is highly possible that the large ion flux to the grounded probe is mainly due to a high voltage plasma sheath present above the probe surface. The plasma sheath is a layer of electric field formed owing to the potential difference between the plasma potential and the probe potential [
13]. Using a Langmuir probe, a plasma potential of larger than 120 V has been estimated in the DC mode [
9], causing electron suppression to the grounded probe. Therefore, the electron flux to the probe can be negligible compared to the ion fluxes. In other words, the measured probe current can be used to represent the ion flux (
Γi) to the probe as
Γi ~
Ip/(
qiAp), where
qi is the average charge of the ion species (mostly singly charged ions) which is 1.6 × 10
−19 C and
Ap the probe area.
The corresponding ion flux, calculated from the probe current, is also shown in
Figure 3. The ion flux during the HiPIMS pulse dramatically increased to a peak of
Γi,peak ~ 10
21 m
−2s
−1. It was two orders of magnitude higher than the ion flux of ~10
19 m
−2s
−1 during the DC mode [
9].
Figure 4 shows the peak ion flux
Γi,peak determined near the pulse terminal (
t ~ 250–300 µs) as a function of the peak of the discharge current
Id,peak. It can be seen that the
Γi,peak was mostly proportional to the
Id,peak, especially in the high current range. The increase of the ion flux mainly contributed to the large discharge current, as well as the discharge power generating the dense plasma during the HiPIMS mode.
The dense plasma increased not only the ion flux but also the sputtered particles. More importantly, the sputtered nickel particles could be effectively ionized in the plasma and could be the major contributor to the thin film deposition process.
Deposition rates (
Rd) of nickel films obtained from the QCM reading as a function of the average discharge power (
Pd,avg) are shown in
Figure 5. It is worth mentioning that the average discharge power was calculated using the equation
The deposition rate tends to increase with the average HiPIMS power. The maximum deposition rate for the given process condition was about 1.1 Å/s.
In a conventional HiPIMS discharge, during which the negative driving voltage is applied to the target, the plot between the deposition rate and the discharge power density shows a less-than-linear curve [
14]. This is due to the returning effect, where the positive metal-ions return to the target, decreasing the deposition rate, particularly at the high discharge power level [
15]. This may be not the case for the inverted magnetron. The metal ions created in the inverted magnetron can readily be extracted to the substrate using the positive driving voltage. As a result, a linear deposition rate curve was observed, as seen in
Figure 5.
It has been pointed out that the flakes of accumulated film in the magnetron could cause a short-circuit between the cathode and the anode [
8]. However, by operating the inverted magnetron in the HiPIMS mode, the amount of the flakes in the magnetron could possibly be reduced, due to ionization and the extraction of the sputtered particles.
4. Discussion
It is reasonable to assume that the discharge mostly occurs inside the magnetron. Therefore, the target surface adjacent to the plasma could be sputtered. In the DC mode, sputtered particles (e.g., Ni) could either be deposited on the anode surface or leave the magnetron through the cathode gap along with the Ar+ ions. In the HiPIMS mode, the plasma density inside the magnetron was expected to be high. Considerable amounts of sputtered particles in the magnetron can be ionized, (e.g., Ni+ and Ni2+), and extracted through the gap forming metal-rich plasma to the substrate.
Using the ion flux probe together with the QCM probe allows us to understand the conceptual idea as follows. The total ion current, obtained from the electrically grounded probe, is proportional to the metal ion flux (
Γmi) and gas ion flux (
Γgi), written as:
Or
where
qi and
Ap are the elementary charge on the ion and the probe area, respectively.
In the case of QCM, the deposition rate is proportional to the combination between the metal ion flux (
Γmi) and the metal neutral flux (
Γmn), written as:
Or
where
K is a constant related to the specific process conditions, e.g., the actual density of the depositing film, the target to substrate distance, working pressure, etc.
Since
K in Equation (4) is difficult to determine, we focus attention on the relations Equations (1) and (3). The ratio between total ion current,
Ii, and deposition rate,
Rd, for the HiPIMS mode could be written as:
The ratio
Ii/
Rd is proportional to the summation of two terms. The first term is the ionized metal flux fraction,
Θm =
Γmi/(
Γmi +
Γmn) [
16]. The second term is the ionized gas flux to total metal flux fraction,
Θg =
Γgi/(
Γmi +
Γmn).
Figure 6 shows
Ii/
Rd as a function of the average discharge power operating in the DC mode and the HiPIMS mode. The ratio of
Ii/
Rd during the DC mode remains nearly constant. This ratio, however, significantly increases when applying the HiPIMS pulses to the magnetron.
The general trends of
Ii/
Rd shown in
Figure 6 agree well with Equation (5). In the DC mode, the
Γmi to the probes can be negligible, owing to the low plasma density. In this case, the
Ii/
Rd ratio is proportional only to
Γgi/
Γmn. Even though increasing the DC power may increase both
Γgi and
Γmn, the measured
Ii/
Rd ratio is observed to stay nearly constant for the given range of the DC discharge power. In contrast, in the HiPIMS discharge mode with a peak power of a few kW,
Γmi and the consequent
Θm can significantly increase. This is mainly due to the enhancement of the ionization of nickel atoms in the high density plasma. The ratio of
Ii/
Rd in the probe position is then observed to increase with the increasing average power.
Operating the magnetron in the HiPIMS mode enhances not only the ionized metal flux fraction
Θm at the probe position, but also the density of energetic Ni
+ ions (and high ionization states). In our previous work [
9], it was shown that the most probable kinetic energy,
Em, of ions extracted from the magnetron is closely related to the discharge voltage,
Vd. Using the data in [
9], we can roughly estimate that
Em ~ 0.7
qVd (
q is the elementary charge). In the present work,
Vd during the HiPIMS pulse is about 350 V (see
Figure 2a). Therefore, the
Em of Ni
+ is approximately 240 eV, corresponding to the ion speed of 2.8 × 10
4 m/s. Using the measured flux of 1.7 × 10
21 m
−2s
−1 (see
Figure 3), the density of Ni
+ during the HiPIMS pulse was estimated to be approximately 6.0 × 10
16 m
−3.
Despite the high density of the energetic Ni
+ ions, the performance of the gapped magnetron can be discussed as follows. The target gap is similar to the racetrack of the conventional target, where most electrons are effectively confined. In the gapped configuration, the target erosion mostly occurs near the edge of the target gap. We can expect that the gap width will be progressively wider for long-term operation. Furthermore, the discrete erosion may cause an additional instability to the discharge, in particular, when operated in the HiPIMS mode [
17]. Further investigation needs to systematically and carefully be performed in order to validate the gapped configuration, both in term of plasma and thin film characterization.