Innovations and Insights about Caliper Verified Unrestricted Kinematic Alignment a Personalized TKA Concept

A special issue of Journal of Personalized Medicine (ISSN 2075-4426). This special issue belongs to the section "Methodology, Drug and Device Discovery".

Deadline for manuscript submissions: closed (1 September 2022) | Viewed by 27350

Special Issue Editors


E-Mail Website
Guest Editor
Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
Interests: focused on clinical outcomes; biomechanics; implant design of caliper verified kinematically aligned TKA

E-Mail Website
Guest Editor
1. Orthopädische Klinik König-Ludwig-Haus, Lehrstuhl für Orthopädie der Universität Würzburg, 97074 Würzburg, Germany
2. Department of Biomedical Engineering, University of California, Davis, CA 95616, USA
Interests: knee biomechanics; total knee replacement; total knee arthroplasty; kinematic alignment

Special Issue Information

Dear Colleagues,

We are pleased to invite you to contribute to the Special Issue of the JPM. The Special Issue focuses on: innovations and insights about kinematic alignment, a personalized TKA (total knee arthroplasty) concept. We encourage you to submit a research paper that reflects your contribution to the clinical advancement of kinematic alignment. We appreciate your contribution to this Special Issue and remain at your disposal for any further information you may require.

Prof. Dr. Stephen M. Howell
Dr. Alexander J. Nedopil
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Journal of Personalized Medicine is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2600 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • kinematic alignment
  • caliper verified
  • total knee arthroplasty
  • total knee replacement
  • knee biomechanics

Benefits of Publishing in a Special Issue

  • Ease of navigation: Grouping papers by topic helps scholars navigate broad scope journals more efficiently.
  • Greater discoverability: Special Issues support the reach and impact of scientific research. Articles in Special Issues are more discoverable and cited more frequently.
  • Expansion of research network: Special Issues facilitate connections among authors, fostering scientific collaborations.
  • External promotion: Articles in Special Issues are often promoted through the journal's social media, increasing their visibility.
  • e-Book format: Special Issues with more than 10 articles can be published as dedicated e-books, ensuring wide and rapid dissemination.

Further information on MDPI's Special Issue polices can be found here.

Published Papers (10 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Other

8 pages, 612 KiB  
Article
Excessive Sagittal Slope of the Tibia Component during Kinematic Alignment—Safety and Functionality at a Minimum 2-Year Follow-Up
by Yaron Bar Ziv, Gilad Livshits, Konstantin Lamykin, Salah Khatib, Yuval Ben Sira, Oded Rabau, Noam Shohat and Ahmad Essa
J. Pers. Med. 2022, 12(9), 1407; https://doi.org/10.3390/jpm12091407 - 30 Aug 2022
Cited by 2 | Viewed by 1919
Abstract
The aim of this study was to assess the safety and functional outcomes of excessive sagittal alignment in the unrestricted kinematic alignment technique for total knee arthroplasty (TKA). A retrospective, single-center study was conducted between 2018 and 2020, including patients undergoing primary TKA [...] Read more.
The aim of this study was to assess the safety and functional outcomes of excessive sagittal alignment in the unrestricted kinematic alignment technique for total knee arthroplasty (TKA). A retrospective, single-center study was conducted between 2018 and 2020, including patients undergoing primary TKA with a minimum 2-year follow-up. EOS imaging conducted before and after surgery was reviewed for overall alignment, and a number of measurements were taken, including sagittal tibial slope and other tibia and femur component positioning. Patients were interviewed and asked to fill out several questionnaires including a visual analog scale, the Oxford Knee Score, and the Knee Injury and Osteoarthritis Outcome Score. Overall, 225 patients (66.7%) had a sagittal tibial slope angle above 5° (excessive) and 112 (33.3%) patients had an angle under 5° (moderate). A significant improvement in pain and function scores was observed in both groups following the surgery (p < 0.001). There were no significant differences between the moderate and excessive groups in the average VAS, OKS or the various subtypes of the KOOS score. However, there was a slight but significant difference in the number of patients achieving MCID in KOOS symptoms. There were no cases of early failure or loosening. Unrestricted KA and the excessive sagittal alignment of the tibial component seem to be reliable and safe in terms of restoring daily function and alleviating pain after a minimum of 2 years following the surgery. Full article
Show Figures

Figure 1

9 pages, 2453 KiB  
Article
Kinematic Alignment in Total Knee Arthroplasty Reduces Polyethylene Contact Pressure by Increasing the Contact Area, When Compared to Mechanical Alignment—A Finite Element Analysis
by Antonio Klasan, Andreas Kapshammer, Veronika Miron and Zoltan Major
J. Pers. Med. 2022, 12(8), 1285; https://doi.org/10.3390/jpm12081285 - 5 Aug 2022
Cited by 7 | Viewed by 2602
Abstract
Unrestricted Kinematic alignment (KA) in total knee arthroplasty (TKA) replicates the joint line of each patient by adjusting the cuts based on the anatomy of the patient. Mechanical alignment (MA) aims to restore a neutral mechanical axis of the leg, irrespective of the [...] Read more.
Unrestricted Kinematic alignment (KA) in total knee arthroplasty (TKA) replicates the joint line of each patient by adjusting the cuts based on the anatomy of the patient. Mechanical alignment (MA) aims to restore a neutral mechanical axis of the leg, irrespective of the joint line orientation. The purpose of the present study was to compare contact pressure and contact areas of the polyethylene (PE) bearing surface as well as von Mises stress of the PE-tibial tray interface for MA and KA in the same patient, using CT data and finite element analysis. Finite element models were created from lower leg CT scans of 10 patients with knee osteoarthritis with different phenotypes. Mechanical PE properties were experimentally determined by tensile tests on dumbbell specimens. For numerical simulation purposes an adjusted non-linear material model with the maximum load to failure of 30.5 MPa, was calibrated and utilized. Contact pressure points were the deepest parts of the polyethylene inlay. Contact pressures were either very similar or were increased for MA knees throughout the gait cycle. KA either increased or had a comparable contact area, compared to MA. KA and MA produced comparable von Mises stresses, although both alignments breached the failure point of 30.5 MPa in all 3 valgus knees. This might indicate a higher probability of failure at the inlay-tibial baseplate interface. By maintaining the joint line orientation, KA reduces or has comparable contact pressures on the PE bearing surface by increasing or maintaining the contact area throughout one gait cycle in a validated finite element analysis model in 10 different knee phenotypes. The von Mises stress on the PE-tibial component interface was comparable, except for the valgus knees, where the load to failure was achieved in both alignment strategies and slightly higher stresses were observed for KA. Further studies for different knee phenotypes are needed to better understand the pressure changes depending on the alignment strategy applied. Full article
Show Figures

Figure 1

8 pages, 876 KiB  
Article
Minimum 2-Year Radiographic and Clinical Outcomes of Unrestricted Kinematic Alignment Total Knee Arthroplasty in Patients with Excessive Varus of the Tibia Component
by Yaron Bar Ziv, Ahmad Essa, Konstantin Lamykin, Najib Chacar, Gilad Livshits, Salah Khatib, Yoav Comaya and Noam Shohat
J. Pers. Med. 2022, 12(8), 1206; https://doi.org/10.3390/jpm12081206 - 25 Jul 2022
Cited by 2 | Viewed by 1918
Abstract
Kinematic alignment (KA) total knee arthroplasty (TKA) has gained much attention in recent years. However, debate remains on whether restrictions should be made on the tibia cut. The purpose of this study was to assess the safety and functional outcomes of excessive varus [...] Read more.
Kinematic alignment (KA) total knee arthroplasty (TKA) has gained much attention in recent years. However, debate remains on whether restrictions should be made on the tibia cut. The purpose of this study was to assess the safety and functional outcomes of excessive varus cuts. A single-center, retrospective analysis of consecutive patients undergoing TKA between 2018 and 2020 who had a minimum 2-year follow-up was conducted. EOS™ imaging conducted before and after surgery was analyzed for overall alignment, as well as for tibia and femur component positioning on the coronal planes. Patients were interviewed and asked to fill several questionnaires, including the visual analog score, Oxford knee score, and knee injury and osteoarthritis outcome score. Overall, 243 patients (71.9%) had a coronal tibial plate angle under 5° (moderate) and 95 patients (28.1%) had an angle above 5° (excessive). There were no significant differences between the moderate and excessive groups in patient-reported outcomes, nor were there differences in the number of patients achieving the minimal clinical difference. There were no cases of catastrophic failure or loosening. Unrestricted KA and excessive varus of the tibial component appears to be safe and efficient in relieving pain and restoring function for a minimum of 2 years following surgery. Full article
Show Figures

Figure 1

12 pages, 3357 KiB  
Article
Surgeon Dominated Design Can Improve the Accuracy of Patient-Specific Instruments in Kinematically Aligned TKA
by Liang Wen, Zhiwei Wang, Desi Ma and Tiebing Qu
J. Pers. Med. 2022, 12(8), 1192; https://doi.org/10.3390/jpm12081192 - 22 Jul 2022
Cited by 2 | Viewed by 1573
Abstract
Precise bone resection is mandatory for kinematically aligned total knee arthroplasty (KA-TKA). This study is to investigate whether surgeon-dominated design can alter the accuracy of patient-specific instrumentation (PSI) in KA-TKA compared with the engineer design. A total of 24 patients (24 knees) who [...] Read more.
Precise bone resection is mandatory for kinematically aligned total knee arthroplasty (KA-TKA). This study is to investigate whether surgeon-dominated design can alter the accuracy of patient-specific instrumentation (PSI) in KA-TKA compared with the engineer design. A total of 24 patients (24 knees) who underwent KA-TKA in our institution were assigned to an engineer design group (10 knees) and surgeon design group (14 knees) chronologically. A novel portable medical-engineer interactive application can greatly enhance the surgeon’s participation in PSI design. The bone resection discrepancies were used to evaluate the accuracy of PSI in bone resection. The overall discrepancy of bone resection was reduced by surgeon-designed PSI compared to engineer-designed PSI by 0.33 mm. Surgeon-designed PSI seems to reduce the outliers in terms of relative discrepancies in bone resection as well, but it does not reach statistical significance. Moreover, surgeon-designed PSI could significantly improve the accuracy of PSI in the restoration of the joint line in terms of medial proximal tibial angle and mechanical lateral distal femoral angle. This study indicates that the dominance of surgeons in both PSI design and subsequent surgical operation should be emphasized in efforts to improve the accuracy of PSI. Full article
Show Figures

Graphical abstract

9 pages, 1179 KiB  
Article
Minimum 2-Year Radiographic and Clinical Outcomes of Kinematic Alignment Total Knee Arthroplasty in the Valgus Knee
by Yaron Bar-Ziv, Eran Beit ner, Konstantin Lamykin, Ahmad Essa, Ron Gilat, Gilad Livshits, Noam Shohat and Yiftah Beer
J. Pers. Med. 2022, 12(7), 1164; https://doi.org/10.3390/jpm12071164 - 18 Jul 2022
Cited by 2 | Viewed by 2222
Abstract
Kinematic alignment (KA) total knee arthroplasty (TKA) has gained popularity in the past decade, but outcomes of KA-TKA in the valgus knee have never been specifically evaluated. In this retrospective single institution study, we analyzed patient reported outcomes and radiographic measurements at minimum [...] Read more.
Kinematic alignment (KA) total knee arthroplasty (TKA) has gained popularity in the past decade, but outcomes of KA-TKA in the valgus knee have never been specifically evaluated. In this retrospective single institution study, we analyzed patient reported outcomes and radiographic measurements at minimum 2 years following KA-TKA for valgus knees (n = 51) and compared the results to KA-TKA performed for non-valgus knees (n = 275). The same approach, technique, and implants were used in both groups without the need to release soft tissues or use constrained implants. Surgery duration was similar between groups (p = 0.353). Lateral distal femoral angle was lower in the valgus group postoperatively (p = 0.036). In both groups significant improvement was seen in relieving pain and improving function, while average scores were superior in the non-valgus group for visual analog score (p = 0.005), oxford knee score (p = 0.013), and knee injury and osteoarthritis outcome score (p = 0.009). However, these differences did not translate to statistically significant differences in minimal clinical important difference achievement rates. In conclusion, KA-TKA is efficient in relieving pain and improving function, as reported in subjective questionnaires, and holds advantage in patients with valgus alignment by avoiding soft tissue releases and use of constrained implants. Future studies should examine whether bone loss occurs in the lateral distal femur. Full article
Show Figures

Figure 1

11 pages, 1700 KiB  
Article
A Surgeon That Switched to Unrestricted Kinematic Alignment with Manual Instruments Has a Short Learning Curve and Comparable Resection Accuracy and Outcomes to Those of an Experienced Surgeon
by Alexander J. Nedopil, Anand Dhaliwal, Stephen M. Howell and Maury L. Hull
J. Pers. Med. 2022, 12(7), 1152; https://doi.org/10.3390/jpm12071152 - 16 Jul 2022
Cited by 14 | Viewed by 1780
Abstract
After starting an orthopedic practice, a surgeon with a fellowship in mechanically aligned (MA) TKA initiated this study to characterize their learning curve after they switched to unrestricted kinematic alignment (KA) TKA using manual instruments. Accordingly, the present study determined for the inexperienced [...] Read more.
After starting an orthopedic practice, a surgeon with a fellowship in mechanically aligned (MA) TKA initiated this study to characterize their learning curve after they switched to unrestricted kinematic alignment (KA) TKA using manual instruments. Accordingly, the present study determined for the inexperienced (IE) surgeon the number of cases required to achieve consistent femoral resections and operating times, and whether the femoral resection accuracy, patient-reported outcome measures (PROMs), and component alignment were different from an experienced (E) surgeon. This prospective cohort study analyzed the IE surgeon’s first 30 TKAs, all performed with KA, and 30 consecutive KA TKAs performed by an E surgeon. The resection accuracy or deviation was the calipered thickness of the distal and posterior medial and lateral femoral resections minus the planned resection thickness, which was the thickness of the corresponding condyle of the femoral component, minus 2 mm for cartilage wear, and 1 mm for the kerf of the blade. Independent observers recorded the femoral resection thickness, operative times, PROMs, and alignment. For each femoral resection, the deviation between three groups of patients containing ten consecutive KA TKAs, was either insignificant (p = 0.695 to 1.000) or within the 0.5 mm resolution of the caliper, which indicated no learning curve. More than three groups were needed to determine the learning curve for the operative time; however, the IE surgeon’s procedure dropped to 77 min for the last 10 patients, which was 20 min longer than the E surgeon. The resection deviations of the IE and E surgeon were comparable, except for the posterolateral femoral resection, which the IE surgeon under-resected by a mean of −0.8 mm (p < 0.0001). At a mean follow-up of 9 and 17 months, the Forgotten Joint Score, Oxford Knee Score, KOOS, and the alignment of the components and limbs were not different between the IE and E surgeon (p ≥ 0.6994). A surgeon that switches to unrestricted KA with manual instruments can determine their learning curve by computing the deviation of the distal and posterior femoral resections from the planned resection. Based on the present study, an IE surgeon could have resection accuracy, post-operative patient outcomes, and component alignment comparable to an E surgeon. Full article
Show Figures

Figure 1

8 pages, 3722 KiB  
Article
The Morphology of a Kinematically Aligned Distal Femoral Osteotomy Is Different from That Obtained with Mechanical Alignment and Could Have Implications for the Design of Total Knee Arthroplasty
by Quan-Hu Shen, Ji-Woong Baik and Ye-Yeon Won
J. Pers. Med. 2022, 12(3), 422; https://doi.org/10.3390/jpm12030422 - 8 Mar 2022
Viewed by 2534
Abstract
Background: Kinematically aligned total knee arthroplasty (KA-TKA) may lead to a different pattern of osteotomy from mechanically aligned total knee arthroplasty (MA-TKA). This paper aims to analyze the effects of KA and MA on the morphology of the distal femoral osteotomy surface. Methods: [...] Read more.
Background: Kinematically aligned total knee arthroplasty (KA-TKA) may lead to a different pattern of osteotomy from mechanically aligned total knee arthroplasty (MA-TKA). This paper aims to analyze the effects of KA and MA on the morphology of the distal femoral osteotomy surface. Methods: Computed tomography scans of 80 TKA candidates were reconstructed into 3D models. The measurement of bone morphology was performed after the distal femur cut according to two different alignment techniques. The aspect ratio, trapezoidicity ratio, and asymmetry ratio of the distal femur were assessed. Results: The aspect ratio and the asymmetry ratio in the KA group was significantly lower than that in the MA group in the general population (p < 0.001). The trapezoidicity ratio in the KA group was significantly higher than that in the MA group in the general population (p < 0.001). Conclusions: It was found that KA-TKA and MA-TKA presented different morphologies of the distal femoral osteotomy surface, and this difference was also influenced by gender. The surgery pattern of KA-TKA and MA-TKA and gender should be considered when surgeons choose femoral prostheses. Full article
Show Figures

Figure 1

10 pages, 417 KiB  
Article
Comparative Cost Analysis of Four Different Computer-Assisted Technologies to Implant a Total Knee Arthroplasty over Conventional Instrumentation
by Bernhard Christen, Lars Tanner, Max Ettinger, Michel P. Bonnin, Peter P. Koch and Tilman Calliess
J. Pers. Med. 2022, 12(2), 184; https://doi.org/10.3390/jpm12020184 - 30 Jan 2022
Cited by 19 | Viewed by 3669
Abstract
Several computer-assisted technologies, such as navigation and robotics, have been introduced to Total Knee Arthroplasty (TKA) in order to increase surgical precision and reduce complications. However, these technologies are often criticized due to the increased costs and effort associated with them; however, comparative [...] Read more.
Several computer-assisted technologies, such as navigation and robotics, have been introduced to Total Knee Arthroplasty (TKA) in order to increase surgical precision and reduce complications. However, these technologies are often criticized due to the increased costs and effort associated with them; however, comparative data are missing. The aim of the present study was to evaluate differences in intraoperative workflows and the related perioperative cost-profiles of four current computer-assisted technologies, used to implant a TKA, in order to gain a comparison to conventional instrumentation. For the cost analysis, additional preoperative imaging and instruments, increased operating room (OR) and planning-time, and expenditures for technical support of the equipment and disposals were calculated, in comparison to conventional TKA, for (1) standard computer-navigation, (2) patient specific instruments (PSI), (3) image-based robotic assistance, and (4) imageless robotic assistance. Workflows at four expert centers which use these technologies were reviewed by an independent observer. The total cost calculation was based on a 125 TKA per year unit in Switzerland. Computer-navigation resulted in 14 min (+23%) increased surgery time and, overall, USD 650 in additional costs. PSI technology saved 5 min (8%) OR time but it created USD 1520 in expenditures for imaging and disposals. The image-based robotic system was the most expensive technology; it created overall additional costs of USD 2600, which predominately resulted from technical support, disposals, the CT-Scan, and 14 min of increased OR time. The imageless robotic assistance resulted in the largest increase in OR-time, as it resulted in an additional 25 min (+42%) on average. Overall, additional costs of USD 1530 were calculated. Every one of the assistive technologies in this study increased the total cost of TKA when compared to a conventional technique, and the most important variables, related to cost, were technical support and additional disposables. The longer surgical times and additional surgical trays required for the techniques had a marginal effect on overall costs. This comparative cost analysis gives valuable information for future efforts to calculate the real costs of these technologies and the subsequent return on investment of each technique. Full article
Show Figures

Figure 1

10 pages, 9145 KiB  
Article
Ethnical Differences in Knee Phenotypes Indicate the Need for a More Individualized Approach in Knee Arthroplasty: A Comparison of 80 Asian Knees with 308 Caucasian Knees
by Lukas B. Moser, Silvan Hess, Jean-Baptiste de Villeneuve Bargemon, Ahmad Faizan, Sally LiArno, Felix Amsler, Michael T. Hirschmann and Matthieu Ollivier
J. Pers. Med. 2022, 12(1), 121; https://doi.org/10.3390/jpm12010121 - 17 Jan 2022
Cited by 16 | Viewed by 5490
Abstract
The purpose of this study was to determine the distribution of functional knee phenotypes in a non-osteoarthritic Asian population. The Stryker Orthopaedic Modeling and Analytics (SOMA) database was searched for CT scans of the lower limb meeting the following inclusion criteria: patient age [...] Read more.
The purpose of this study was to determine the distribution of functional knee phenotypes in a non-osteoarthritic Asian population. The Stryker Orthopaedic Modeling and Analytics (SOMA) database was searched for CT scans of the lower limb meeting the following inclusion criteria: patient age at time of image >18 and <46 years, no signs of fractures and/or previous surgery and/or degenerative changes, Asian ethnicity. A total of 80 CT scans of 40 patients were included (24 males, 16 females). The hip-knee-ankle angle (HKA), femoral mechanical angle (FMA) and tibial mechanical angle (TMA) were measured. Based on these measurements, each limb was phenotyped according to the previously introduced functional knee phenotype concept. All angles and phenotypes of the present study were compared with previously published data of a non-osteoarthritic Caucasian population (308 legs of 160 patients, 102 males, 58 females). Asian knees had a significantly lower TMA (both genders p < 0.001) but a higher FMA (males p < 0.05, females p < 0.001) than Caucasian knees but showed no difference in the HKA. Asian knees differed significantly with regard to femoral and tibial phenotypes (p < 0.01), but not with regard to limb phenotypes. The high variability of all coronal alignment parameters highlights the importance of a detailed analysis prior to TKA. Ethnical differences underline the need for a more individualized approach in TKA. Full article
Show Figures

Figure 1

Other

Jump to: Research

9 pages, 758 KiB  
Case Report
Kinematic Alignment of Failed Mechanically Aligned Total Knee Arthroplasty Restored Constitutional Limb Alignment and Improved Clinical Outcomes: A Case Report of 7 Patients
by Elliot Sappey-Marinier, Scott A. Wu and Stefano A. Bini
J. Pers. Med. 2022, 12(11), 1780; https://doi.org/10.3390/jpm12111780 - 28 Oct 2022
Cited by 3 | Viewed by 2384
Abstract
Background: Stiffness and mid-flexion instability (MFI) is a recognized complication of mechanically aligned (MA) total knee arthroplasty (TKA). Kinematic alignment (KA) has been proposed as a means by which to restore normal joint motion following TKA and potentially avoid stiffness and MFI. Several [...] Read more.
Background: Stiffness and mid-flexion instability (MFI) is a recognized complication of mechanically aligned (MA) total knee arthroplasty (TKA). Kinematic alignment (KA) has been proposed as a means by which to restore normal joint motion following TKA and potentially avoid stiffness and MFI. Several studies have documented improved function with KA when compared to MA. The aim of this study was to determine if revising MA TKAs failed for either MFI or stiffness into KA resolves MFI, achieves better range of motion, and improves clinical outcomes. Methods: A retrospective, single surgeon review was performed. All consecutive TKAs revised from MA into KA for MFI (def: >5 mm opening between 10° and 45° of flexion) or stiffness (def: flexion ≤90°) between January 2017 and May 2021 were included. The constitutional limb alignment of the operated knee was “reverse engineered” by measuring the coronal alignment of the contralateral healthy knee or pre-operative x-rays. Femoral Rotation was set at 3 degrees internal to the trans epicondylar axis. All coronal and sagittal angles were digitally measured on pre- and post-operative long leg and maximum flexion radiographs (minimum 12 month follow-up). The Knee Society Score (KSS) and range of motion assessments were collected preoperatively and at final follow-up. Comparisons between groups were done with a paired T test. Significance was set at p < 0.05. Results: Seven patients were included. Two were male, the mean age was 70.1 years (±9.3), mean follow-up was 32 months (±26). Three patients were revised for MFI and 4 for stiffness. Constitutional limb alignment was restored within 2 degrees for all patients. The mean total KSS gain was 65.9 (±18.1). The total KSS was significantly improved in all patients (p < 0.001). The mean maximum flexion gain was 30 deg (±23°) (p = 0.01). MFI was absent in all patients. Conclusion: In a limited series of patients, revision of stiff or unstable TKA from MA to KA resulted in improved range of motion by 30° on averages, resolved instability without the use of constrained liners, improved clinical outcomes with a mean gain of 75 points on the KSS, and restored constitutional limb alignment within 2 degrees in all patients. As these short term results are promising, further study is warranted. Full article
Show Figures

Figure 1

Back to TopTop