1. Introduction
The precise value of liquid complex permittivity and, less often, permeability is required in many fields of science, technology and industry such as chemistry, biology, medicine, agriculture, geophysics, radio communications, remote sensing, etc. Reference liquids are required for calibrating dielectric and microfluidic sensors [
1] applied in dielectric spectroscopy [
2]. At microwave frequencies, the most precise and reliable data are typically acquired by measuring liquid samples in test cells with vector network analyzers (VNAs) operating over very broadband frequency ranges. The permittivity is then determined from the VNA measurement data, but its accuracy still heavily depends on test cell design and methods applied to its extraction.
In the literature, there are diverse broadband methods for determining properties of liquids with a VNA [
3,
4,
5,
6]. Most of them have their roots in the idea of the transmission-reflection (T/R) technique, known also as the Nicolson-Ross-Weir (NRW) approach [
7,
8] which was introduced to measure properties of isotropic, homogeneous solid state materials. Typical measurements of liquids are carried out in a wave guiding cell whose space is closed by dielectric plugs. The liquid under test (LUT) has to fill this space completely, but it might be difficult due to air bubbles that need to be utterly removed before the measurement. Since the plugs are fixed, usability of such a structure is limited to specific liquids as regard their attenuation. Moreover, to correctly extract the LUT permittivity, the plugs affecting the measurements, have to be properly modeled, what, unfortunately, results in rather complex formulae [
9,
10].
Semi-open cells operating in vertical position, which are partly filled with liquid and air, as a waveguide one presented in [
3] are more versatile. They allow dosing certain volume of a liquid to provide the best conditions for measuring the sample. Moreover, the actual height of the liquid column in the cell can be determined from the reflection coefficient measurements [
3] and applied to the permittivity computation with the NRW formulae [
8]. A similar approach to measuring samples in semi-open coaxial cells was presented in [
11]. Both techniques ignored, however, the fact that the top surface of the liquid column may depart from a flat and transversal plane as it is usually assumed in the T/R methods. In reality, the surface is curved due to meniscus and this may cause errors in the determination of column height and consequently in the liquid permittivity characterization.
The issue of meniscus has been recently addressed in [
12,
13] where a more advanced technique than [
11] has been introduced. Instead of two, this new technique exploits three measurement states, i.e., the empty-cell state and the other two with different volumes of liquid. Since all the measurements are performed without disassembling the cell, the measurement results exhibit higher consistency. The method utilizes the transfer matrices measured to form a similarity transformation, from which the propagation constant and the permittivity of liquid are extracted. However, the heights of liquid columns, necessary to this end, were still determined with the Somlo’s method [
3], i.e., without considering the meniscus. A search [
13] on meniscus effects in the permittivity measurements of distilled water samples, performed up to 18 GHz in a 7 mm line-standard test cell, showed that the errors caused by meniscus are rather small. Unfortunately, finite residual errors of the VNA calibration impeded discerning them in the de-embedded scattering parameters of the samples or in the column height determination. However, comparisons of the permittivity results calculated with different methods demonstrated evident advantages of this new three-state technique [
12,
13]. Nevertheless, one may expect that meniscus may have a stronger influence on accuracy of such permittivity measurements at higher frequencies when wave guiding structures of smaller size are required.
In this paper, we further improve the three-state technique with a novel algorithm for processing the transfer matrices measured. This algorithm de-embeds a transfer matrix representing the volume increment of the liquid sample and yields its column height, calculated using a novel closed-form formula. Therefore, the method is, for the first time, capable of completely removing any impact of reproducible meniscus on the permittivity and permeability determination. In
Section 2, we present our model for the sample measurement and a novel algorithm for determining the height increment of the sample and its propagation constant along with the characteristic impedance. We validate the meniscus removal method in
Section 3 by comparing our experimental results obtained for distilled water, propan-2-ol (IPA), and 50% aqueous solution of IPA with relevant results calculated using the NRW method [
3,
11], and with available reference data.
2. Theory
A sketch of a vertically oriented semi-open coaxial test fixture, employed for measuring liquids is shown in
Figure 1 in its three different measurement states. As seen there, these states are related to three volumes of the LUT in the test cell; zero (empty cell), initial and final ones, which will be indexed with
, respectively. The mathematical description of this fixture and thus the theory of meniscus-removal method, we introduce here, is built on the underlying assumption about single mode propagation of TEM (transverse electromagnetic) waves in the test fixture. Then, the scattering matrices
of the fixture measured with a calibrated VNA are converted to the transfer ones according to
because such a notation enables describing each state of the cell in a compact form.
For a
k-th state, the transfer matrix of the
fixture can be written down as:
where
and
represent relevant sections of the cell filled with
air and liquid
sample, respectively, while
describes the
bottom part of the fixture consisting of the plug and the airline section at the port 2. All these matrices are referenced to the same characteristic impedance
of the airline the cell is based on.
In the case of empty cell,
, where
is the identity matrix and then (
2) reduces to
where, for given both the propagation constant
and the physical length
of the airline section, its matrix
is determined by
Thus,
is utilized as in [
11,
12] to remove
from (
2) and extract components representing a
k-th state of the test
cell itself
On the assumption that the meniscus is reproducible in each state with liquid in the cell, the transfer matrices
can be related to each other as follows:
where
stands for the initial LUT column of height
, as shown in
Figure 1b, while
and
represent the increment of the airline length and the LUT height, respectively
see
Figure 1c. In contrast to both matrices in (
6) and (
7) related to the
increment it is assumed that, due to the meniscus,
may generally represent electrical properties of an asymmetrical two-port network, for which sum of the off-diagonal terms may not be zero—see (
1) for
.
To de-embed
, we need to remove the product of
from (
7). Since
, we finally arrive at
where
is described by (
4) for
substituting
. After multiplying the matrices in (
9), we get
where quantities
are the relevant terms of matrices
for
. In (
10),
is the sole unknown parameter. So we determine it from the condition of electrical symmetry regarding
representing a section of the liquid sample between two ideal planes that are transversal to its axis. For such a sample
and then
where
r represents the above ratio of the measured quantities. This ratio can be expressed in terms of the scattering matrix by using the relationships (
1). Then, it can be interpreted as a quotient of two reflection coefficients
and
where
while index
for
. Finally, we determine the length increment from (
12)
The above method and formulae for determining
and
have been presented for the first time. For the de-embedding applied to sample’s volume increment, the method is capable of removing errors caused by the meniscus provided it is reproducible. Because the terms
and
may be exposed to errors in the reflection coefficient measurements performed by a VNA over a broad frequency range, we employ a robust statistical optimization to assess single value of
from the data calculated using (
14) at each frequency.
Once
is assessed, the matrix
can be directly calculated from (
9). However due to unavoidable errors, we obtain a perturbated matrix
that does not perfectly match its theoretical model:
where
denotes the transfer matrix of an abrupt
transition on the boundary between air and the liquid
while
stands for the reflection coefficient at this interface
Since (
15) represents a matrix similarity transformation, the trace of each side in (
9) is the same and hence we get
From this, we determine the LUT propagation constant
Having the eigenvalues of (
15) determined, we extract its relevant eigenvectors, from which we then calculate the reflection coefficient:
where
and
are elements of
. This leads us to characteristic impedance of the liquid-sample line section:
The determined quantities
and
allow us to extract both the relative permittivity
and permeability
of LUT in the usual way—see (
22), (
23) in
Section 3.
3. Experimental Results
The design of our coaxial test fixture for the liquid characterization followed the general idea of [
3]. The fixture was based on 7 mm line standard with 7 mm laboratory precision connectors (LPC-7) [
14]. For VNA calibration we used manufactured earlier airline standards [
15]. To provide the same properties as those standards and keep costs low, body of the fixture was machined in an in-house workshop from a brass rod. Its body was equipped with a center conductor, a PTFE annular plug, as illustrated in
Figure 1, and a stub pipe for dosing liquids through a small hole in the body. A picture of the fixture, vertically mounted in the measurement setup, is shown in
Figure 2.
Prior to the characterization of liquids, we calibrated our VNA in the frequency range from 0.1 to 18 GHz with the airline standards [
15] and the multiline method [
16]. This calibration yielded, as its byproduct, such characteristics of the airline as its attenuation and phase constants as well as the characteristic impedance
. These data were then utilized to calculate the permittivity and permeability of LUTs.
We measured scattering matrices of the fixture in all its three states for distilled water, IPA and 50% aqueous solution of IPA. We applied the meniscus removal technique, as described in the
Section 2, to determine the propagation factor
and calculate the reflection coefficient
. Since the symmetry assumption on the de-embedded volume increment of the sample is of key importance for our approach, we first checked the ratio
r (
12) to see how well it adheres to the theory. In
Figure 3 we show the magnitude and angle of this ratio versus frequency for all the liquids measured. Since for low-loss airline the magnitude of the left side (
11) is close to unity, deviations from it seen in
Figure 3a, may be attributed to some residual errors of the VNA calibration.
From the ratio (
12), we calculated then the height increment
at each measurement frequency using (
14). The results are showed in
Figure 4 on relevant graphs for a different increment of each liquid with blue lines. Again, due to the residual errors, the curves evidence regular ripples that rise at low frequency end, because of increasing sensitivity of this calculation to errors, which results from a finite angular resolution of the characteristics shown in
Figure 3b. To preclude effects of the abnormal deviations, we applied a robust statistical optimization for assessing a single value of
for (
15). The optimized values of the sample height increments are shown with red dashed lines on the graphs along with their
boundaries drawn with gray dots for better perceiving. These graphs evidence that the relative errors caused by the ripples decrease with the increment of column height that is, however, limited by liquid attenuation. So for the increment, the lowest relative errors can be attributed to LUT having the largest inclination of its characteristic in
Figure 3b.
For the known height increments, we then determined the relative permittivity of liquids at the assumption of their relative permeability
. To this end, we utilized the propagation constant determined with (
19), from which we calculated
where
is the angular frequency and
stands for the speed of light in air. We compared results of our new method with the outcomes of classic NRW method [
11]. As this method employs only a single volume of liquid, we can determine the permittivity for the initial and the final volumes of LUT, independently. To calculate the height of liquid columns
, we used solution proposed in [
3]. Although for
, the NRW method allows calculating
from both the transmission and reflection coefficients independently [
11], we decided to present here results of the former ones for their higher consistency.
The results of water permittivity measurements are shown in
Figure 5. As a reference we used the data taken from [
17], where authors proposed a refined model of water permittivity up to 25 THz for temperature range 0–100 °C. We can observe very good consistency of our results (red dashed-dotted lines) with the reference (blue lines). Relative difference in the real part of permittivity between our method and the reference does not exceed 2.5% in the entire bandwidth, except the first point at 0.1 GHz, where it reaches 6%. The imaginary part yields convergence better than 3.5% above 3.5 GHz. The NRW results for the initial volume of liquid (purple dashed lines) are rather distant from the reference. A better agreement is obtained for the final volume (green dots), because of its higher column of water, the impact of liquid surface distortions is smaller and thus results in improved accuracy.
The IPA permittivity results are presented in
Figure 6 along with the reference data are taken from [
18] at 30 °C (blue lines), but certified below 5 GHz. The measured characteristics have similar shape to the reference ones, although are shifted in frequency. The reason may be a high sensitivity of the IPA relaxation frequency (related to the peak of
in
Figure 6b) to the temperature [
18]. Except the low frequency end, the NRW method used for the final volume of IPA (green dots) yields almost the same results as our meniscus removal method (red dashed-dotted lines), while outcomes for its initial volume (purple dashed lines) are apart of both for the same reason as stated before.
For the 50% aqueous solution of IPA, we, unfortunately, have not got relevant data for comparison except just static permittivity at room temperature [
19] showed with blue crosses in
Figure 7, confirming that values at low frequency end are reasonable. Likewise for clean IPA, our method (red dashed-dotted lines) yields similar results as NRW one for the final volume of liquid (green dots), whilst outcomes for its initial level (purple dashed lines) are not consistent with them.
Since our novel method allows us to calculate both
and
, we are able to characterize magnetic liquids and determine their relative permittivity and permeability:
As an example of our generic approach, we show the permittivity and permeability of already presented, nonmagnetic IPA, but calculated without assuming any knowledge of its permeability. The results of permittivity obtained for IPA, shown in
Figure 8a,b, agree well with all the previously shown in
Figure 6 which were obtained at the assumption
. Agreement with that assumption is illustrated on the the permeability graphs shown in
Figure 8c,d. Departures from it, easily discerned on the graphs, evidence an asset of the meniscus removal method (red dashed-dotted lines), whose results are close to the reference, however, with some perturbations at higher frequencies caused perhaps by residual errors of the VNA calibration.