1. Introduction
Any medical device, prosthesis or biomaterial creates a trauma following implantation, whereby the presence of the implant subsequently effects the healing of the trauma site. The altered healing process is known as the foreign body reaction (FBR) and results in the worst case in a complete implant rejection [
1]. Thus, the FBR is a key factor in the long-term survival and function of an implanted biomaterial [
2]. During the FBR, macrophages play a major role [
3,
4]. Over time, an initial population of short-lived pro-inflammatory M1 macrophages is replaced by long-vitae M2 macrophages. The chronic accumulation and fusion of these M2 macrophages in the proximity of the implant induces the production of a dense fibrous capsule by fibroblasts, isolating the foreign body from the native tissue [
4].
The FBR is known to be affected by surface properties such as implant topography and chemistry. Here, the interaction between defense cells and especially structures in the nanoregime has gained increasing interest [
5,
6,
7]. The generation of a surface comprising nanofeatures is, in this case, particularly interesting for an extensively used biomaterial like titanium, as can be derived from the variety of manufacturing methods that are applied for this purpose [
8,
9,
10]. A comparably cost-efficient method to generate oriented nanostructures on a large scale is the fabrication of nanotubular surfaces by electrochemical anodization of Ti. Nanotube (NT) arrays were already tested in biomedical applications, demonstrating that these surfaces bear potential in drug delivery, biosensing or surface-modified implants [
11,
12,
13]. An approach to increasing the application domain for nanotube structures is to treat Ti coatings instead of bulk material [
14]. It was found that electrochemical anodization is applicable for samples that are coated by physical vapor deposition techniques, e.g., direct current (DC)-sputtering, radio frequency (RF)-sputtering, electron-beam evaporation, or arc evaporation [
15,
16,
17,
18,
19]. By a combined surface treatment composed of coating and anodization, the surface of relevant implant materials, such as CoCrMo-alloys could be modified [
20]. Thereby, these materials were equipped with a corrosion-resistant, biocompatible, and nanostructured layer that additionally prevents the release of toxic ions from the underlying substrates [
21,
22,
23].
Until now, the immunological response to a nanotubular-structured implant has mostly been investigated with bulk Ti. Ainslie et al. studied the inflammatory response of human monocytes on nanotubes with a diameter of about 80 nm, and could find that establishing a nanostructure on the surface of a Ti sample significantly reduces inflammation [
24]. Moreover, nanotubular topographies are known to trigger differentiation and polarization of human monocytes into M1 or M2 macrophages depending on nanotube diameter [
25]. Small nanotube diameters promote M2 polarization, whereas large nanotube diameters induce polarization towards M1 phenotype. In order to investigate the influence of nanotube diameter on the inflammatory response, murine macrophages were cultured on nanotubes with different diameters ranging from 30 to 100 nm [
26]. Thereby, it was observed that TiO
2 nanotube surfaces have an increased ability for quenching nitric oxide (NO) compared to the conventional control surface. Generated by macrophages in the wake of their natural immune response, NO subsequently causes a number of inflammatory signaling events. The comparative study revealed that nanotubes with a diameter of 70 nm have the strongest effect on the used animal-derived macrophages. A decreased NO activity in the presence of a nanotubular surface was also observed in vivo [
27], whereby the nanostructured implants (nanotube diameter 100 nm) inserted into the abdominal wall of rats resulted in a reduced fibrotic capsule thickness for structured implants, compared to flat Ti surfaces. It was concluded that the catalytic TiO
2 activity is enhanced by the higher surface area due to the presence of the nanotubes. In summary, all currently available studies on the immune-regulatory effects of TiO
2 nanotubes indicate that introducing a nanotubular topography onto an implant surface modulates the behavior of macrophages in the FBR. Although this promising effect has been identified, the specific impact of nanotubular surfaces on each macrophage phenotype has not been elucidated. Due to the distinct roles of each macrophage phenotype during the inflammatory response to an implant, such information would enable us to gain a mechanistic understanding to further improve the nanotubular surfaces to control the FBR. Moreover, all previous studies are either, based on monocytes, macrophages of non-human origin, or on implantation of samples into animals impeding a direct correlation to humans. To establish a reliable in vitro assay, we tested the influence of different nanotube diameters on primary human macrophages with either M1 or M2 phenotype. This experimental approach is also strengthened by the fact that monocytes in vivo differentiate immediately after passing the endothelial barrier and entering the surrounding tissue [
28].
In order to strengthen our results, the experimental procedure was employed to a second set of materials, whose topography could be varied gradually from smooth to different degrees of nanotopography, meaning that the style of the nanostructures is maintained, but their size can be varied. As the variation of anodization voltage in the case of nanotube fabrication allows the control of the resulting nanostructure, in the case of titanium nitride (TiN) coatings prepared by PVD, the process parameters, such as substrate temperature, amount of nitrogen in the process gas, or the deposition time represent adjustable process parameters to control the evolving nano topography [
29,
30]. TiN has a long history in the field of biomaterials, and its various forms have found applications ranging from protective coatings for orthopedic implants to electrodes for nerve stimulation or pacemakers [
31,
32,
33]. Although, there is literature that investigates the in vivo encapsulation of TiN showing a fractal nanotopography, but focused on the inflicted change of electrical parameters due to the fibrous encapsulation, there are no studies that investigate the response of macrophages to this kind of surface structure, and thus, it represents an interesting opportunity for extending the scope of this study and verifying a subtype-specific response of macrophages to nanostructured surfaces [
34,
35].
The aim of this study was to examine the interaction of two different polarizations of macrophages with a carefully selected, manufactured and characterized variety of smooth and nanostructured surfaces, thus searching for significant differences in the respective cell surface interactions. The study of these interactions might give further insight about the future design of implant surfaces whose purpose is the support or impediment of a specific cell polarization or an associated reaction.
2. Materials and Methods
2.1. Substrate Preparation
The glass slides that were used as substrates (Icefrost 76 × 26 × 1 mm³, Menzel, Germany) for the sputtering process were cleaned in subsequent 10-minute ultrasonic baths (Bandelin electronic, Berlin, Germany) with acetone, isopropanol and ultrapure water and were finally dried using nitrogen gas.
2.2. Physical Vapor Deposition (PVD)
As previously described in [
36], the deposition of pure Ti films was done in a vacuum chamber equipped with a magnetron sputtering system and substrate heating. At least 1 h before the deposition, the glass slides were heated to a temperature of 200 °C. Argon was used as sputter gas and a multi gas controller (MKS Instruments, Andover, MA, USA) controlled the flow rate. During deposition, the flow rate was set to 137 sccm for all experiments, which resulted in a pressure of 4.0 × 10
−3 mbar. A 13.56 MHz RF generator (RF 1000, Hüttinger, Freiburg, Germany) was used for magnetron sputtering and was operated at a power of 400 W. The sputtering time was 4 h, thereby creating films with thicknesses of approximately 4 µm. Based on deposition time and film thickness, for sputtering powers of 400 W the deposition rate was calculated as 0.25 nm/s.
For the generation of nanorough TiN coatings, glass slides were first coated for 30 minutes with a layer of Ti with a sputtering power of 500 W and Ar flow rate of 137 sccm, without external heating. The nanorough TiN was then prepared in a gas mixture of Ar 137 sccm and N2 2.0 sccm with the RF generator operated at a sputtering power of first 800 W for 2 minutes and 500 W for 15 (TiN 15) or 60 (TiN 60) minutes afterwards.
Smooth TiN coatings were prepared on a heated substrate holder with a temperature of 200 °C. After depositing a layer of Ti using the same process parameters as for the nanorough coatings, a flow of 2 sccm N
2 was added to the process gas, and the samples were coated with a sputtering power of 800 W (2 minutes) and subsequently 600 W (18 minutes). A summary of the process parameters is presented in
Table 1.
2.3. Electrochemical Anodization
As previously described in [
36], the PVD films were etched for 1 min in diluted hydrofluoric acid (0.5 wt %) directly before placing the samples in the electrolyte. The distance between the Pt-coated stainless steel plate which acted as counter electrode and the working electrode was 2 cm, whereby the homogeneity of the electrolyte was ensured by magnetic stirring. The Ti films were anodized for 2 h using a DC power supply (Voltcraft VLP 1602 Pro, Conrad Electronic AG, Wollerau, Switzerland) and a mixture of phosphoric and hydrofluoric acid (1 M H
3PO
4 + 0.2 wt % HF) [
37]. The as-anodized samples were directly rinsed with ultra-pure water, prior to a subsequent 15-minute ultrasonic bath in ultrapure water to remove all residual electrolyte and a final drying step using compressed air.
Annealing of the as-anodized nanotubes was performed in a high power furnace (L08/14 Nabertherm, Lilienthal, Germany) in air. The target temperature of 450 °C that was reached after a heating time of one hour was maintained for 3 h with a subsequent cool down phase of at least 4 hours.
2.4. Coating Characterization
2.4.1. Morphology and Surface Roughness
The surface morphology of all samples was determined by scanning electron microscopy (Zeiss CB 340, Oberkochen, Germany) and atomic force microscopy (Nanosurf FlexAFM, Nanosurf GmbH, Langen, Germany). The average values of the inner diameters obtained by analysis of scanning electron microscopy (SEM) images of the different nanotube surfaces are arithmetic mean values of 20 nanotubes per specimen. For the analysis and quantification of surface roughness, the standard atomic force microscopy (AFM) instrument software Nanosurf Easyscan 2 was applied. The line roughness values of three different positions on each sample were analyzed with scan field sizes of approximately 5 µm × 5 µm. The measurements were performed in air under tapping mode, using a scan speed of 0.3 s/line, and a silicon cantilever Tap190-Al G (Innovative Solutions Bulgaria Ltd, Sofia, Bulgaria) with a tip radius of about 10 nm or smaller [
36].
2.4.2. X-ray Diffraction
The crystallographic properties of the samples were determined by X ray diffraction (XRD) using a D5005 X-ray diffractometer (Bruker AXS, Karlsruhe, Germany) with grazing angle geometry (angle of incidence 2°) [
30]. The diffractometer used Cu-K radiation with a voltage of 40 kV and a tube current of 40 mA. The diffraction patterns recorded in a 2Θ range from 20–80° were evaluated with the software DiffracPlus EVA (Bruker AXS, Karlsruhe, Germany) and compared with reference patterns from the JCPDS database [
38].
2.4.3. Contact Angle
The analysis of surface wettability was carried out with a contact angle measuring device (OCA 15EC, Dataphysics, Filderstadt, Germany). Directly after preparing the samples, they were cleaned with isopropanol and dried by compressed air. Then, three droplets of 3 µL ultrapure water were dripped onto different parts of the surface of each sample.
2.5. Ethical Clearance Statement
Primary cells for studies addressing cell-biomaterial interactions were isolated from human peripheral blood under informed consent according to ethical approval granted by the institutional ethics committee of the Julius-Maximilians-University Wuerzburg (vote 182/10). Furthermore, procedures were in accordance with the Helsinki Declaration of 1975, as revised in 2008.
2.6. Isolation and Differentiation of Human Monocytes to Macrophages
Mononuclear cells from peripheral blood (University Hospital Wuerzburg, Germany) were isolated according to a previously published protocol [
4]. Briefly, following ficoll gradient centrifugation (GE Healthcare, Freiburg, Germany), monocytes were separated by a negative magnetic cell separation (MiltenyiBiotec, Bergisch Gladbach, Germany) to remove T cells, NK cells, B cells, dendritic cells, and basophils. Obtained monocytes (purity 90 ± 4%) were cultured in RPMI GlutaMax (Gibco, Carlsbad, CA, USA) plus 10% fetal calf serum at a concentration of 1 × 10
6 cells per ml and a density of 1.5 × 10
5 cells per cm
2 on standard polystyrene cell culture dishes (TPP, Trasadingen, Switzerland).
By supplementation of recombinant human granulocyte macrophage colony-stimulating factor (GM-CSF, Peprotech, Rocky Hill, NJ, USA) at a concentration of 40 ng per ml for 6 days, differentiation to the M1 phenotype was triggered. Differentiation of monocytes to the M2 phenotype was induced by supplementation of 40 ng per mL recombinant human macrophage colony-stimulating factor (M-CSF, Peprotech) for the same timeframe. Respective medium in each differentiation experiment was exchanged on Day 3. The cells were harvested by mechanical cell scraping on Day 6.
To ensure the required phenotype, expression of differentiation cluster proteins was characterized in flow cytometry. The expression profile was evaluated by antibody staining of 2 × 105 macrophages per antigen. CD14 (555-397, BD Bioscience, Heidelberg, Germany), CD68 (11-0689-42, eBioscience, Frankfurt am Main, Germany), and CD206 (12-2069-42, eBioscience) were used as positive markers for macrophages. Markers CD80 (12-1639-42, eBioscience) and CD163 (17-1639-42, eBioscience), typically inversely-expressed by M1 and M2 macrophages, were used to proof differentiation towards the required phenotype. The samples were analyzed in a FACS Calibur flow cytometer (BD Biosciences) and data were further processed in FlowJo software (Tree Star, Ashland, OR, USA). The biological variability was covered by using cells isolated from five donors in the respective experiments.
2.7. In Vitro Testing of Biomaterials
To ensure standardized test conditions, a tailored test chamber was used (see
supplementary Figure S1). In this test chamber, macrophages of both subtypes were seeded on (I) glass, (II) Ti, and (III) nanotubular Ti in a cell density of 6 × 10
4 cells per cm
2 at a total medium volume surface ratio of 0.22 ml per cm
2 in RPMI GlutaMax supplemented with 10% heat-inactivated fetal calf serum. All samples were incubated for 48 h at 37 °C and 5% CO
2 conditions. The medium was harvested at 48 h and centrifuged at 10,000 × g
0 for 5 min. The same conditions and the test chambers were also used to analyze the TiN coatings, with cells seeded on (I) glass, (II) smooth TiN, and (III) fractal TiN surfaces. The design of the complete study is presented in
Figure 1.
The experiments in the first part of the study, including four different surface types (two NT surfaces, glass and Ti), were consecutively performed with cells from five human donors. Three samples were tested for each combination of macrophage polarization and surface type, leading to a total number of 24 analyzed samples per donor.
In the second part of the study, the experiments including four different surface types (glass control and three TiN surfaces) were performed with cells from three human donors. The number of samples per donor were composed in the same way as in the first part of the study.
2.8. Immunohistochemical Staining
A standard protocol was performed for immunohistochemical staining on the biomaterial surfaces, as described in [
3]. Briefly, cells were fixed with 4% paraformaldehyde (Carl Roth, Karlsruhe, Germany) for 10 min at room temperature. 2.5% Phalloidin Alexa Fluor 555 (A34055, Invitrogen, Carlsbad, CA, USA) in phosphate buffered saline plus 1% bovine serum albumin (Applichem, Darmstadt, Germany) was incubated for 20 min. Fluoromount-G™, with DAPI (4′,6-diamidino-2-phenylindole, eBioscience) was used for mounting. Antibody against intercellular adhesion molecule CD54 (ICAM-1, AH55411, Invitrogen) allowed visualization of cellular adherence of cells to biomaterial surfaces. The images were captured on a confocal laser scanning microscope (TCS SP8, Leica Microsysteme Vertrieb GmbH, Wetzlar, Germany). Background subtraction and contrast enhancement was equally performed on all images (ImageJ 1.49m, National Institutes of Health, Bethesda, MD, USA). Fluorescent images of macrophages on TiN surfaces were captured on a fluorescence microscope (Axio imager M1, Carl Zeiss, Göttingen, Germany) and were only stained against DAPI and Phalloidin.
2.9. SEM Preparation of Cell-Seeded Materials
After 48 h of culture, cells were washed with PBS- for four times, fixed in 6% glutardialdehyde in PBS- at 4 °C for 15 min and washed five times with chilled PBS for 5 min each. Samples were dehydrated in an ascending acetone series at room temperature. After critical point drying (Critical Point Dryer CPD 030, Bal-Tec, Witten, Germany) and coating with 2 nm of platinum (EM ACE600, Leica, Vienna, Austria), samples were analyzed by SEM (Zeiss CB 340).
2.10. Image Analysis for Morphological Studies
Images were analyzed using ImageJ (1.49m, National institutes of Health). For the assessment of the cell area and aspect ratio, at least 100 cells per cell type and surface were analyzed, therefore, data were merged from all donors. The images for this analysis were captured on a fluorescence microscope (Axio imager M1, Carl Zeiss, Göttingen, Germany). The measured cells were grouped, with a difference in area of 12 µm2 between one group and the following, or a difference in aspect ratio of 0.05, respectively. Subsequently, the number of cells within each single group was counted. In the next step, the percentage of the single groups to the complete distribution within a combination of cell type and surface was calculated. Afterwards, these percentages were integrated and the results for cell area were fitted using a sigmoidal fit, while the results for the aspect ratio were fitted using an asymptotic fit. The derivative of these fit functions then displays a probability density for the covered cell area, and aspect ratio, respectively.
4. Discussion
All implanted biomaterials induce cellular and tissue responses that finally result in the encapsulation of the foreign body [
1]. In this wound healing process, macrophages play a pivotal role. Macrophages originate from monocytes that rapidly differentiate when recruited in the context of inflammation [
39,
40]. At the wound site, macrophages exhibit a spectrum of polarization ranging from pro-inflammatory to anti-inflammatory and pro-healing character, depending on their specific phenotype. Hereby, M1-polarized macrophages are associated with pro-inflammation, whereas M2 macrophages are the dominant phenotype in the remodeling phase of wound healing [
41]. Thus, the impact of a biomaterial on a specific macrophage phenotype is of interest for the improvement of implant materials. A possibility to control the macrophage polarization is to equip an implant with a nanotopography, which can be generated in many different styles, such as nanotubes or pyramid-like fractal nanostructures. The first can be generated on a variety of different implant materials by coating the material with Ti, and subsequently introduce the nanostructure by electrochemical anodization, the latter can be directly produced by a PVD process. Due to the opportunity to fabricate tubular and fractal surface structures, with tunable dimensions in the nanoregime, by simply varying easy-accessible process parameters, such as the anodization voltage or PVD process time. Both PVD and electrochemical anodization achieve a high effectiveness and reproducibility. The controlled fabrication and reproducibility is a prerequisite to studying the impact of different nanostructure dimensions on material-resident cells [
42].
The parameter setting on heated glass substrates, used for the PVD coating process, facilitated fine-grained and smooth coatings suitable for the fabrication of ordered nanotube arrays. Furthermore, higher substrate temperatures increased the temperature stability and adhesion between the deposited film and the substrate. This prevented the nanotubular structures from delamination or damaging by higher temperatures used during the annealing process. A combination of diluted H
3PO
4 and HF and was used for the anodization process. This sort of electrolyte provides a high degree of control regarding the geometry of the NT arrays, especially the diameter of the nanotubes, an effect attributed to the buffering potential of H
3PO
4 [
37,
43]. The produced NT arrays exhibited well-defined tubes, whereby, the average nanotube diameters increased with rising anodization voltage and seemed to be in good accordance with the tube diameters, reported by other groups who anodized bulk titanium at the same range of voltages in electrolyte mixtures of H
3PO
4 and HF [
37]. As expected, the AFM analysis of the nanotubular surfaces exhibited much rougher surfaces compared to the mirror-like Ti coating, whereby larger tube diameters also led to increased surface roughness. The detected increase in the roughness values could be clearly attributed to the tubes’ nanoscale roughness, since the generation of highly reproducible coatings, together with a subsequent defined pre-etching step, minimized the variations of the surface roughness of the underlying PVD coatings.
The nanotube arrays, generated by anodization in H
3PO
4/HF electrolyte, exhibited superhydrophilicity. However, this beneficial property regarding cell adhesion and protein adsorption appeared to be independent of the diameter, and length of the nanotubes, respectively. The increased intensity of the anatase peak in the X-ray diffraction pattern recorded for rising anodization voltages, as well as the simultaneously observable decline of the Ti signal, that was associated with the remaining underlying coating, can be attributed to an increasing thickness of the NT array with rising voltage, an effect that could also be observed at the anodization of bulk titanium [
35]. A typical finding in the diffraction patterns of NT arrays annealed at 450 °C is also the observed phase mixture with a high ratio of anatase to rutile [
42].
In contrast to the nanotube arrays, the TiN coatings could be directly produced via PVD process [
30]. Two sets of coating parameters were used for the fabrication of TiN surfaces. First, using heated substrates, a very smooth coating with roughness values even lower than the pure Ti coating was generated. The second set of parameters without the application of the substrate heating was used to generate surfaces with pyramid-like fractal nanopatterns. The extension of the deposition time led to the growth of the pyramid-like structures, and thus, resulted in larger and well-defined sharp nanostructures. The formation of the self-assembled nanostructures also caused a significant increase of the coatings roughness compared to the as-deposited smooth TiN, whereby the growth of the fractals’ size was also accompanied by a further roughening of the surface. Regarding the wettability of the TiN samples, the contact angle measurement revealed that both the smooth TiN coating and the coating with smaller fractals exhibited contact angles close to the pure Ti coating. Only the larger fractals caused a moderately shift to a more hydrophobic behavior, however the measured angles still were in the hydrophilic regime.
The XRD analysis detected for all samples both signals from the underlying Ti coating and the top layer of TiN. Due to the thickening of the TiN top layer, the signal intensity attributed to the underlying Ti coating decreased, while the intensity of the TiN signals increased with the extension of the deposition time. The signals detected in the XRD analysis, which could be attributed to the different TiN layers could be assigned to a δ-TiN lattice with fcc crystal structure [
29].
Nanotubular topographies have a strong impact on monocyte differentiation into macrophages. In vitro, it was observed that monocytes spontaneously differentiate into macrophages on nanotubular Ti surfaces, and that small nanotube diameters promote polarization towards M2 phenotype, whereas large nanotube diameters result in polarization towards M1 phenotype [
25]. However, in addition to surface properties, also biochemical conditions are known to instruct macrophage polarization [
44,
45]. For example, key mediators of first line humoral surface interaction, e.g., blood plasma proteins modulate cell adhesion, blood coagulation, and complement activation. Moreover, the release of alarm signals to the extracellular space, induced by tissue injury, stimulates the migration of immune cells from the vasculature to local implant region [
38], and thus, it has not been clarified yet whether the polarization effect of nanotubes on differentiating monocytes found in vitro can still be detected in a physiological wound scenario. Additionally, at a wound site without a biomaterial, monocytes rapidly differentiate into macrophages [
40], and it is unclear how differentiated human macrophages are affected when arriving at a nanotubular topography.
A transition between both phenotypes cannot be excluded since the identity of macrophages has been described as rather a continuum than a distinct M1 or M2 phenotype [
46]. Nevertheless, even if a transition occurs, for example from M2 to M1, the cell characteristics of putatively switched M2 macrophages strongly differ from initially M1-polarized cultures. Although, a switch between macrophage phenotypes is theoretically possible, in our previous studies we could not detect a switch after only 48 h of culture, especially without external stimulation of the macrophages [
3,
4].
Following verification of phenotype, M1- and M2-polarized macrophages were cultured on the nanotubular surfaces and respective controls; glass and a mirror-like Ti coating. SEM revealed that, on all surfaces, both phenotype types attached and established an intense interaction with the surface by the formation of cytoplasmic sprouts. Immunohistochemical imaging of cell morphology indicated a phenotype-specific impact of the nanotubes, which was confirmed by statistical analysis of cell surface areas and aspect ratio. While on Ti and nanostructured Ti M1 macrophages exhibited comparable morphological parameters, nanostructured Ti-impaired cell spreading of M2 macrophages. Interestingly, unstructured Ti surfaces promoted elongation of M2 macrophages, which is associated with migration and an increased cell activity [
8]. Reduced cell numbers and cell spreading of human-derived macrophages on nanotube surfaces could also be demonstrated by Smith et al. [
47]. However, it must be noted, that there are two major differences between the studies: (I) Human monocytes there were directly cultured on the materials; and (II) the nanotubes were prepared in a diethylene glycol (DEG) electrolyte, that significantly increased the space between single nanotubes, which resulted in a quite different surface structure.
In an attempt to find out whether the two macrophage phenotypes express a similar morphological reaction when exposed to another type of scalable nanostructure, the M1- and M2-polarized cells were cultured for 48 h on TiN layers, equipped with two different sizes of pyramid-like patterns, with glass and a smooth TiN coating as controls. The SEM analysis of the samples could demonstrate the attachment of the cells to the surface and the establishment of material interaction by cytoplasmic sprout formation. According to the protocols established for the investigation of Ti-NT surfaces, images were taken by fluorescence microscopy and then statistically analyzed. The analysis of these images revealed remarkable similarities between the two series of experiments using different sets of surfaces.
Similar to the previous experiments, the M1 macrophages exhibited a rather round shape on all surfaces. However, the general impact of the TiN nanostructure on the M1 phenotype was lower compared to the Ti-NT surfaces. The cell areas covered by the single cells, were comparably larger and more evenly distributed on all tested TiN surfaces than in the NT experiments. On the smooth TiN surface, which exhibited roughness values close to glass, and therefore, the surface with the lowest roughness value of all generated coatings, the M1 macrophages were wide-spread and had the most homogeneous distribution regarding the area covered by single cells. Remarkably, M2 macrophages, cultured on smooth TiN, had an almost identical probability density regarding the distribution of the aspect ratio compared to unstructured Ti coatings, which means that on both coatings with a different surface chemistry, similarly high ratio of elongated cells could be found. However, the size of the M2 cells was significantly larger than on the smooth Ti coating, which renders this surface, together with the fact that the measured cell numbers were close to the glass control samples, possibly the best accepted coating for the M2 phenotype.
Although, TiN-60 coatings only seem to have limited influence on the M1 phenotype, these sharp pyramid-like nanopatterns had a significant impact on the M2 phenotype, indicated by drastically reduced cell numbers and cell sizes. This finding is in very good agreement with the results for the NT surfaces, whereby the impact of the TiN 60 coating on the M2 cell size seem even stronger than the impact of the large diameter nanotubes.
The most obvious difference between both experiments can be found when comparing the two samples that were equipped with small diameter nanotubes (NT 10V) and smaller fractal patterns (TiN 15), respectively. Where the cells of both M1- and M2-phenotype had more or less similar morphologies on NT 10V and NT 20V surfaces, the macrophages’ morphologies of both phenotypes on the TiN 15 coatings closely resembled the morphologies on the smooth TiN coatings. Thus, even for the M2 macrophages that were quite sensitive to both tube sizes and the larger fractals, there seems to be a threshold regarding the size of the nanostructures that could actually limit their spreading and cell activity.
Low cell numbers of M2 macrophages on nanotube and fractal surfaces, compared to M1 macrophages and impaired cellular activity led to the assumption that the nanostructured coatings are less tolerated by M2-polarized macrophages than smooth Ti or TiN coatings. Whereas, the impact of the investigated nanostructures on M1-polarized macrophages was limited. An exception to this were the TiN-15 surfaces, which probably exhibited nanostructures small enough to be more tolerable for the M2-phenotype.
An explanation for the phenotype-specific impact of the nanotubular structures could be that M1 and M2 macrophages differ regarding their complexity and function. While, the synthesis of pro-inflammatory cytokines is an attribute for M1 macrophages, M2 macrophages are equipped with several receptors for endogenous and foreign body molecules [
48], which indicates a more sensoric function. Moreover, in contrast to M1 macrophages, the secretome of M2 macrophages comprises more proteins, M2 macrophages differentiate in different M2 subtypes [
39], the M2 phenotype modulates more processes in the FBR [
41], and M2 polarization is based on a stronger interaction with various immune cells [
41,
49,
50]. Thus, the complex range of function could be an explanation why M2 macrophages respond more sensitively to their nanoenvironment.