1. Introduction
Blast-resistant buildings are designed for use in hazardous industries, such as oil and gas industry projects where various types of fires (such as pool and jet fires) as well as vapor cloud explosions are common in different hazardous scenarios. These multidisciplinary complicated projects have a clear path to specify hazards and explosions in order to define the necessity of blast-resistant buildings. In this regard, first, different hazards through a hazard and operability (HAZOP) and hazard identification (HAZID) analysis are identified. Consequently, a safety impact level analysis (SIL) evaluates the probability of safe operation in different risky scenarios. Afterwards, based on a consequence analysis (CA), a project is zoned, and its layout is designed. Finally, if important buildings, such as control rooms, are located in one of the hazardous areas, the building has to be designed to resist an explosion wave.
Identifying probable and possible dangers means a critical role in preparing to confront and resist the negative effects of radical attacks in urban zones and regions. The main aim of pathology is to identify facilities, immunize the answers of buildings to radical attacks, and resist the effects of explosions [
1]. On the one hand, the resistance of a building to an explosion wave depends on the shape and the form of the building and the roof, the number of entries and casements, and the power and genus of the materials used. On the other hand, a building façade is considered to be the first barrier protecting against waves of a proximate explosion. Thus, it seems important to study and evaluate various materials used in a façade against the consequences of an explosion. In Iran, an outer façade is usually built after constructing the outer wall, which consists of some materials such as decorative brick, cement, and stone.
This research compared different types of building facades against explosion waves. The materials used in a building play an important role in a building’s vulnerability. Considering the influence and role of building materials in the effects of an explosion, buildings can be classified into three different categories, according to studies of and experience from previous wars and recent wars [
2]:
Buildings with damage-aggravating materials: A glass façade can be considered to be an example of this category. Basically, glass facades severely increase people’s vulnerability to the environment. The surface under falling glass pieces will extend proportionally to incremental height. Thus, a lot of fatal glass pieces will be thrown outside just by the effects of the sonic barrier being broken;
Buildings with vulnerable materials: Some materials or a combination thereof are not resistant enough against waves and quivers, and they will cause serious damage at the time of an explosion;
Buildings with fewer vulnerable materials: Some buildings whose façades are composed of rigid-like materials, such as concrete, or a combination of materials, such as fibrous concrete, can be put into this category. These buildings can be more resistant to explosions and will be less vulnerable. Thus, due to the mentioned cases, the main goal of this research was the absence of indices for assessing and selecting the best kinds of materials to use in the façades of buildings in Iran. In the field of buildings resistant to explosion, a lot of research has been done. Some of it is mentioned now.
Gebbeken & Döge [
3] studied the structure geometry of preventing blast waves from getting to buildings. The results fundamentally concluded that in geometric shapes, maximum pressures and maximum impulses depend on the distance from the explosion location, the confliction angle of explosion waves, and the resistance to the progress of waves of structural shapes. The shape of structural ingredients or building ingredients is certainly able to decrease explosion loads.
Barakat & Hetherington [
4] accomplished similar research. Their study was of blast effects on different forms of structures, such as cubic, cylinder, half-cubic, and prismatic forms, and they concluded that in addition to the structural components of a building, architectural forms can also have a great effect on reducing explosion effects on buildings. Mojtahed Pour [
5] can be mentioned as another example. In this study, the effects of structure shape on stress distribution from explosion loading was examined: In addition, the research was more on structural aspects of the issue, as in some parts he focused on the effect of indicatives in structures.
Luccioni et al. [
6] can also be pointed to as a related and important study in this area. The aim of this study was a failure analysis of buildings with concrete structures under an explosion load. They modeled a three-dimensional model from a concrete building using ANSYS Autodyn software and concluded that the failure mechanism started from the lower columns of the building, and the building was destroyed. Buildings resistant to explosion have developed through so many studies [
7,
8,
9,
10,
11,
12,
13]. These studies have focused on the impact of architectural elements on the vulnerability of structures to earthquake hazards.
The federal agency Crisis Management of America accomplished some research on buildings resistant to explosion. For instance, the research of the Federal Emergency Management Agency (FEMA) number 426 [
14] can be mentioned, which presented some finite regulations for designing building façades and some factors, such as casements and the genus of mentioned materials.
As mentioned in the history of the research, many studies in the field of buildings resistant to explosion have been done so far. In this study, some types of building facades and related materials that are commonly used for resisting explosions were considered. Consequently, the characteristics of each façade material were investigated. Then, the research methodology used was a pairwise assessment to evaluate the efficiency of different facades based on the presented indices (criteria). Finally, as the conclusion, the most appropriate kind of façade is presented as the first resistance barrier against an explosion. In doing such a study, the best kind of facade is specified in order to reduce damage from an explosion to an acceptable level of damage through observing the obtained results from this research, which should be applied to buildings built in Iran in the future.
2. Types of Materials in Building Facades
The types of most widely used facades in Iran are as follows.
2.1. Brick Façade (A1)
Brick, which is usually performed on the outer walls of buildings, is one of the oldest materials in façades in Iran. The color and quality of the mentioned bricks differ from other types of bricks. The most common types of façade bricks are Cossack bricks, Bahmani bricks, 3-cm bricks, and fireproof bricks. The advantages and disadvantages of bricks are discussed here.
Due to the rigidity of this type of façade, the ability to transfer energy from an explosion to the outer wall of a building is high, and consequently this does not have enough of an effect on reducing an explosion effect.
Due to the heavy weight of the brick and the possibility of detachment of the crustal from the outer wall, such a façade is not suitable enough for debris removal.
Due to integration and simultaneous implementation, some large surfaces have less of a reconstruction ability.
Due to the high thermal capacity of the brick in this façade, it has an appropriate capability against fire.
2.2. Stone Façade (A2)
Due to the rigidity of this type of façade, the ability to transfer energy from an explosion to the outer wall of a building is high, and consequently this does not have enough of an effect on reducing the explosion effect on a building.
Due to the heavy weight of the building stones and the possibility of detachment of the crustal from the outer wall, such a façade is not suitable enough for debris removal.
Due to integration and simultaneous implementation, some large surfaces have less of a reconstruction ability.
Due to the high thermal capacity of this type of façade, it has an appropriate capability against fire.
2.3. Coatings Cement Façade (A3)
Due to the low thickness of the materials used in this type of facade, the ability to transfer energy from an explosion to the outer wall of a building is high, and consequently this does not have enough of an effect on reducing explosion effects.
Due to its low weight and the adherence of a concrete façade to an outer wall, in such a façade there is not much debris.
Due to the type of implementation, it has a high reconstruction ability.
Due to the low thickness of the materials in this façade, it has little effect against fire.
2.4. Composite Façade (A4)
Due to the lack of rigidity in this type of façade, the ability to transfer energy from an explosion to the outer wall of a building is lower, and consequently this has a high effect on reducing the explosion effect on a building.
Due to its low weight and a proper connection to the outer wall, such a façade seems to be suitable enough for debris removal.
Due to a lack of integration and block implementation, it has a high reconstruction ability.
Due to the low thermal capacity of this type of façade, it has an appropriate capability against fire.
2.5. Curtain Wall (A5)
Due to the lack of rigidity in this type of façade, all waves and quivers from an explosion enter a building easily.
Debris from the shattering of glass causes injuries to people and damage to equipment.
Due to the low thickness of glass and its material characteristics, it is not capable enough against fire.
Due to glass having a lack of resistance to explosion, it will be completely destroyed and will need to be replaced completely.
3. Methodology
In this study, first, the materials used in building façades in Iran were identified through library resources in order to evaluate the materials used in buildings to protect building façades from the effects of an explosion. Second, all of the indicators on the long proposed list were extracted by interviewing experts in the fields of civil engineering and architecture (
Table 1 for the case study) to assess building façades against the effects of an explosion. Next, a Delphi technique in combination with fuzzy set theory (to cope with uncertainty) was used to evaluate the identified criteria list to represent the most important criteria list to be used in an assessment process. Then, a questionnaire was presented to a panel of experts to obtain their ideas in order to measure effective indices. For this purpose, fuzzy Delphi applied to select and examine criteria. Eventually, priorities and the final weight of indices were determined through fuzzy EDAS. The procedure and process of the research is shown in
Figure 1.
This approach tries to make results more robust in comparison to common approaches in the Multiple Attribute Decision Making (MADM) field. This study tried to apply fuzzy logic, a literature review, and a Delphi method to suggest the best criteria for evaluating proposed alternatives. Fuzzy EDAS was applied to consider all alternatives more accurately (as much as possible) based on expert evaluations.
3.1. Fuzzy Delphi
Different fuzzy Delphi techniques have been presented in the multiple-criteria decision-making (MCDM) literature. However, this study was developed based on a classic form of the method [
15]. The proposed technique in this study was a combination of gray numbers, fuzzy set theory, and a Delphi technique, as follows.
Step 1 (expert panel): Experts were asked to provide an interval value (gray number) as a representation of the relative importance of the intended criteria. Here, denotes the ith respondent in the kth iteration for the pth alternative.
Step 2 (fuzzification): The interval values were turned into a fuzzy membership function based on the frequency and overlap of the intervals developed by the panel of experts. Thus, based on the experts’ responses, the universe was divided into some intervals to calculate the frequencies through the following methodology:
where
I denotes the number of experts participating in the research, and
denotes the primary membership function for the fuzzy number related to the
pth alternative,
Step 3 (normalization): The fuzzy number measured for every criterion was divided by the highest value so that the membership function was defined between 0 and 1:
Step 4 (defuzzification): The center of gravity (COG) was the proposed methodology used to defuzzify the proposed fuzzy number. Finally, the average value for each criterion was measured:
Step 5 (consensus evaluation): If the linear absolute distance of the calculated average value () with all of the respondents’ defuzzified values (the COG) was less than 0.7, the answer converged and the process for this criteria was stopped.
3.2. Fuzzy Evaluation Based on the Distance from the Average Solution (Fuzzy EDAS)
EDAS is an effective MCDM methodology that was developed in 2015 based on measuring the deviation from the average solution. The efficiency of this MCDM methodology has been evaluated in comparison to prior valid methodologies, such as Vlse Kriterijumska Optimizacija Kompromisno Resenje (VIKOR), Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS), Simple Additive Weighting (SAW), and COmplex Proportional Assessment (COPRAS), with consistent results [
16]. As ambiguity is an important condition in most problems, a combination of fuzzy set theory and EDAS was developed one year later [
17].
Recently, fuzzy EDAS has been developed in new studies, and some new ones are mentioned here (as follows):
In supplier selection [
17];
In solid waste disposal site selection [
18];
For subcontractor evaluation [
19];
For supplier evaluation and order allocation with environmental considerations [
20];
For the evaluation of construction equipment with sustainability considerations [
21];
In hydrogen mobility roll-up site selection [
22];
For evaluating suppliers [
23].
In this study, fuzzy EDAS methodology and its calculation procedure were mainly based on previous studies [
17], as follows.
An assessment methodology was proposed through the following five steps.
Step 1 (determining the average distance): We assumed
n alternatives were defined as a screened building façade and
m criteria were considered in the assessment process. In addition, the number of respondents was set as
k. Thus, the average distant matrix was calculated as follows:
where
denotes the
pth respondent opinion about alternative
i with respect to the
jth criterion.
Step 2 (calculating criteria weight): The criteria average weight based on the respondents’ opinions was calculated as follows:
where
denotes the weight of the
pth respondent on the
jth criteria weight.
Step 3 (negative and positive distances from the average): Average responses with regard to every criterion were calculated as follows:
Then, the positive distance from the average (pda), as well as the negative (nda), were calculated as follows:
where
, and
is the defuzzification function.
Consequently, the calculated distances from the average were weighted as follows:
Step 4 (calculating the normal value): In order to calculate the normal value and remove the units, all of the values had to be divided by a maximum value, as follows:
Step 5 (calculating the alternatives’ score and ranking): Based on the proposed methodology, assessment scores were calculated as follows:
5. Conclusions
As mentioned above, a building façade is the first barrier resisting waves and quivers from an explosion, and it plays a determining role in decreasing a building’s vulnerability and human casualties. Thus, in this research, we tried to assess various widely used materials in this part of a building (due to effective indices). To do so, 5 out of 10 indices were considered, including reducing an explosion’s effect, debris removal capability, resistance to fire capability, reconstruction capability, and implementation costs. In this regard, a list of 10 important indices (as a criteria list) was developed based on expert opinions and was screened using a fuzzy Delphi technique to find the five most important indices in the rest of a façade assessment. According to the screening phase results, reducing an explosion’s effect had the most influence on selecting the proper façade, and then implementation costs were placed in the next rank. As a consequence of the screening phase, an assessment of different façade materials was practiced using fuzzy EDAS. Based on the results, a “coatings cement facade” was recognized as the best alternative to building a façade to enhance resistance to an explosion wave. In addition, a “stone facade” was selected as the second best material, with a minimal difference in the importance factor. However, other alternatives were steeply lower in importance and are not recommended for use as façade materials in blast-resistant buildings. The proposed methodology can be used to evaluate other materials in other case studies, based on different project environments, available options, and other standards and specifications according to a project’s obligations.