3.1. Mode II Strain Energy Release Rate of the Unidirectional CFRP Composite
Typical load vs. displacement curves resulted from the 3ENF test on the particular unidirectional CFRP composites with two types of starter defects are depicted in
Figure 2. The CFRP composite with insert film as starter defect (CFRP1) showed that force increases linearly, reaches a peak value, and experiences a sudden load drop. This brittle failure response, in which sudden drop occurred after the composite reached its fracture point, is typical for CFRP composites under flexural loading [
13,
14,
15]. CFRP composites may at times exhibit stiffness degradation (decreasing slope of the curve) just before failure [
15]. However, this particular composite seemed to not show such a phenomenon. For CFRP composite with mode II pre-crack as starter defect (CFRP2), the force linearly increases, followed by a nonlinear increase to reach the peak value, and declines nonlinearly within short displacement range after reaching peak value, then finally drops. The CFRP2 samples seem to exhibit degradation of stiffness just before failure [
15].
As mentioned above, some CFRP composites exhibit similar stiffness degradation just before failure. Previous observation on unidirectional CFRP composite under flexural loading found that internal failure actually occurs—it even begins at load of about 60% of the failure load, even for composites which show brittle fracture where no detectable nonlinearity was present [
13,
14]. The researchers proved it by measuring acoustic emission signal transmitted by the flexure loaded specimen, and at the same time captured its images in situ. The stages of failure mechanism of flexural loaded unidirectional CFRP was perceived to be initiated by fiber breakage (at about 60% of failure load), followed by matrix cracking alongside broken fibers, followed by partial delamination (just before failure load), and finally abrupt crack propagation (at and beyond failure load) [
13]. Thus, failure mechanism of CFRP1 which showed brittle failure response might also initiate from fiber breakage, like what seemingly happened to CFRP2. Although macroscopic observation of load-displacement measurement did not detect the initial stage of failure. Whether this initial analysis is correct still needs to be proven with more data. It should be noted, however, that there is no report on similar failure mechanism analysis on unidirectional CFRP composites under end-notch flexure test. Nor is there a report that analyses why certain CFRP composites show stiffness degradation, while others do not.
In terms of point of failure, CFRP1 failed at a higher peak load and at a higher elongation at break than CFRP2. The former’s slope was also higher than that of the latter. There are some possible reasons for CFRP1 (sample with insert film as starter defect), showing both higher stiffness and strength compared to its Mode II pre-cracked counterparts (CFRP2). First, there are resin bags adjacent to the thin film in CFRP1 (
Figure 3), while there is none in CFRP2. This resin bag is vested in CFRP1, considering the fabrication method, in which the thin film used to make the end-notch region was actually slotted within stacks of pre-pregs [
16,
17]. The consequence of these resin bags is the occurrence of sites with lower fiber fraction ratio (higher matrix content). Hence, the higher elongation at break shown by CFRP1. The second reason for the higher stiffness, strength, and elongation at break of CFRP1, compared to those of CFRP2, is that the interface adhesion between the matrix and carbon fiber in the former was higher than it was in the latter. The cause for this difference in interfacial adhesion might be in part from the subpar performance of the CFRP2. If the first reason is true, in which there are sites with lower fiber volume fractions in CFRP1, then CFRP2 which contains no such site should exhibit higher stress and strain. Causes for this include the induced microcracks at the fiber-matrix interface and more areas of shear stress concentration, both of which may possibly occur if the crack front is wider than when the starter crack was a thin film. In other words, the crack front is curved or nonlinear, as opposed to its linear initial condition, similar to the crack front feature in previous reports [
16,
18].
By using Equation (1), the fracture toughness or critical energy release rate under mode II fracture (G
IIC) was calculated. It was calculated that the G
IIC for CFRP1 was 1.98, while the G
IIC for CFRP2 was 0.96. Peak load value was used to determine the corresponding critical load, considering CFRP2 showed small region of nonlinearity while CFRP1 did not. The initial G
IIC for the sample with insert film as starter defect (CFRP1) was higher than that for the sample with Mode II precrack as starter defect (CFRP2). Referring back to Equation (1), considering crack length (
a) and sample size (
b and
h) were constant, the difference in G
IIC values was due to the Young’s modulus (
E) and the critical load (
PC) of the CFRP composites. CFRP1 exhibited slightly higher Young’s modulus and much higher critical load and, hence, its higher G
IIC. This result is in agreement with previous studies [
3,
6,
16].
Presence of resin bags in CFRP1, as mentioned above, might be the cause [
17]. Resin bag’s fiber volume fraction is low, which means it has a higher matrix content. The higher G
IIC of CFRP1 might be reflected from this corresponding higher matrix content at the resin rich crack tip. Additionally, crack front condition of the CFRP2 might be influential as well. As mentioned above, there is possibility that the crack front of CFRP2 might be curved, which means the crack front is longer than the initially linear crack tip. Damage zone developed at the crack tip dissipates some portion of the total external energy the sample was subjected to (by shear loading), before macroscopic propagation [
16]. The longer the crack tip, as in CFRP2’s supposedly curved crack front, the more strain energy dissipated prematurely and did not reflect in the bulk composite’s force-displacement curve. Hence, the lower G
IIC of CFRP2.
Another trial was made on the CFRP2 sample by subjecting it to another round of 3ENF test, herein termed CFRP2’ for convenience. The load vs. displacement curve of CFRP2’ is similar to that of CFRP2, including the nonlinear decrease after the peak point (i.e., stiffness degradation). In terms of critical energy release rate under Mode II fracture, the GIIC of CFRP2’ was similar to CFRP2. A possible explanation for this similar Young’s modulus, strength, elongation at break, and GIIC is the crack front of CFRP2’ resembled that of CFRP2, which is curved. This similarity was a preferred indication of reproducibility, when mode II pre-crack was used as starter defect for 3ENF test of unidirectional CFRP composite.
Regarding the G
IIC values obtained by the 3ENF test, this study found that unidirectional CFRP composite with mode II pre-crack as starter defect showed a more conservative G
IIC value, compared to the value shown by composite with insert film as starter defect. Previous works on 3ENF tests of unidirectional composites [
3,
6,
16], which also recorded similar findings, stated that the obtained G
IIC value was not sensitive to thin film thickness (prior to making the pre-crack) and length of the pre-crack. This current study adds that the G
IIC value is also insensitive to the number of pre-cracks that the sample was preconditioned by.
Among factors which were said to be influential to the G
IIC is the thickness of the thin film as starter crack. It was recommended that the thin film insert’s size should be less than 30 µm [
4] in order to minimize its effect on G
IIC (due to the occurrence of resin bags). The thickness of the insert film used to make the unidirectional CFRP composites in this study was 23 µm, so it complied. Still, the discrepancy between the G
IIC values of CFRP1 and CFRP2 was apparent. So, it was more on the less performing CFRP2, perceived here due to development of damage zone in the form of microcracks at curved crack front, which were longer than if it was linear.
Another factor that influenced G
IIC was the selection of critical load; be it the one where nonlinearity starts, or the one at peak point [
16]. When the former was selected as the critical load, it resulted in even lower G
IIC for CFRP2. This study used the peak load as the critical load, considering that at the peak load, the composite can still withstand the external load it is subjected to, even though the damage zone already initiates. Friction is another factor which might affect the G
IIC. This friction occurs because shearing happens, and the end-notch surfaces are in contact one another. Yet, a report showed that friction does not influence Mode II fracture test [
18]. This means, friction also did not affect the results in this study. Overall, taking into account the conservativeness and consistency of the G
IIC results, this study recommends the use of pre-crack as a starter defect in 3ENF test of unidirectional CFRP composites whenever applicable, especially for design purposes.
3.2. Crack Front Profile
In
Section 3.1, it was perceived that the crack front profile of CFRP2 was curved. Previous reports actually have stated about this [
16,
19,
20]. However, no evidence was brought up yet, which is understandable considering limitations of currently available imaging technology. X-ray imaging, which is expected to be the enabling technology, still has limitations in which contrast between carbon fiber and epoxy matrix in CFRP is too low, in addition to the relatively low resolution of the system. Thus, detailed information which might be helpful for fracture analysis (e.g., fiber breakage, fiber-matrix interfaces, microcracks, and delamination) is difficult to obtain. This study explores the use of micro CT scan to obtain as much information as possible about the crack front to help analyze the finding related to G
IIC.
Studies demonstrate that the x-ray microtomography technique using CT scans can be used to reveal matrix damage, such as micro crack and delamination in CFRP composites [
21]. Analysis of damage mechanism using this technique is greatly assisted if there is sufficient contrast between matrix and fibers (in terms of x-ray attenuation), so the setting should be adjusted to obtain this. Initial trial was performed on 3ENF tested CFRP composites with insert films as starter defect (CFRP1), and the result was depicted in
Figure 4. The starter defect and subsequent damage due to the 3ENF test on CFRP1 could be visualized. The system and setting were capable of getting adequate contrast to differentiate air from the bulk of CFRP1. The rendered image obtained from the micro CT scan is three dimensional and can be treated as one (e.g., sliced to view a certain section). However, the resolution is still too low to clearly differentiate between the fiber from the matrix.
From the available 3D image (one representation is in
Figure 4), the cracked CFRP1 features the curved crack front. This micro CT image of curved crack front profile, as the result of 3ENF test on unidirectional CFRP composite, is currently the first one ever reported. A previous report [
16] had indirect analysis that crack front of 3ENF tested CFRP was curved, but no image was shown as evidence, and attempts to verify this by sectioning and acoustic emission were unsuccessful.
As for 3ENF tested CFRP composites with mode II precrack as starter defect (CFRP2), its crack front also shows a similar curved profile (
Figure 5). This finding supports the analysis about the less performing CFRP2, which was perceived due to its curved (which means longer than initially linear) crack front. It should be noted that the shown crack front was obtained after the 3ENF test. The initial crack front is the one obtained after the 3ENF test of CFRP1, thus it corresponds to the curved crack front profile of CFRP1. This means there actually was no apparent change in the length of the crack front for CFRP2, since it started with a curved crack front and ended also with a curved crack front (the length was even slightly reduced). Chances are that the CFRP2 did not show subpar properties, as observed in previous section (judging from load vs. deformation curve alone). It readily showed consistent behavior in terms of G
IIC. Similar G
IIC of CFRP2’ (when CFRP2 was subjected to another round of 3ENF test) from that of CFRP2 verified this. This finding is in line with the current recommendation to use G
IIC obtained from 3ENF tests on unidirectional CFRP composites for design consideration for showing conservative and consistent values.
Clearer view on the damage zone of the CFRP2 sample can be seen from
Figure 6 where the top and front views are presented. Wavy crack front when seen from front view is apparent. The insert film used to make the end-notch (starter defect) for the composites was expected to produce flat crack front. However, since the rigidity of thin PTFE film is low, the thin film could not resist the tendency for ply waviness during fabrication [
14,
15,
20]. Seen from the top and front views, it is obvious that the crack front of CFRP2 was curvy, with propagation more towards both edges and less in the center region. The curved crack front was opposite to that observed by Davies et al. [
16], who reported that the crack propagation at the specimen center was up to 2 mm longer than on the edges.
Comparing the crack front profile between that obtained from mode II fracture test found in this study and mode I fracture test performed previously [
19], the orientation of the curve was the opposite (
Figure 7). The propagation pattern that eventually becomes the final crack front profile might be governed by the location of the site of initial crack. Considering the crack front profiles of CFRP1 and CFRP2 reported here, it seems crack initiation started from the edges. The microcracks might initiate from sites with less matrix content (higher fiber volume fraction) at the edges, created when the specimen was sectioned. This observation that the crack initiated at the edges puts a doubt to analysis in
Section 3.1, where the cracks initiated due to fiber breakage like what happened to flexure tested CFRP composites [
13].
A remark on this 3ENF test, is that since the crack front was curved, and the reading of crack length which commonly is done from the edges might be compromised. The measured crack length might not be representative. The reading can be an overestimation like what was found in this study. In other circumstances, it can also be an underestimated value from samples which feature a crack at the center, propagated more than on the edges. The reading of crack length influences the G
IIC value. An example from this study is given in
Table 1. The difference in crack length and the corresponding G
IIC can be twofold when the reading is taken from the edge, which showed most propagation compared to that when the reading was taken from the center. Thus, when possible, calculation of G
IIC which comes from reading of crack length at edges should be avoided, or the deviation should be presented as well. There are ways to obtain G
IIC other than from direct reading of the crack length at the edges. One of them is proposed by Tanaka et al. [
6], which measures crack shear displacement to calculate G
IIC. This method was demonstrated to result in non-significant differences in toughness values calculated from equations based on crack length or based on crack shear displacement.
3.3. Fractography Analysis
Fractography analysis on 3ENF tested CFRP composites was done using scanning electron microscope (SEM). It was intended to complement the analysis on damage mechanisms on the unidirectional CFRP composites. Another intention was to verify the findings from micro CT scans, since the rendered images resolution of the scanned object was not so high. The 3ENF tested samples were opened to reveal the paths of crack propagation. The analysis was done only on the CFRP2 sample, since it featured both the traces of crack front from 3ENF tested CFRP1 and the final crack front of CFRP2 itself. Considering the small area coverage of SEM, the images should be captured from multiple sites of interest within the sample. A schematic drawing showing the locations of the SEM observation taken on the sample is depicted in
Figure 8. To help clarify the location, top view of the sample showing the location of SEM observation was also presented (
Figure 8). What to observe in
Figure 9a is the trace of a crack front left behind by 3ENF tested CFRP1. Four locations were observed for this purpose. Point 1 was at the pre-cracked area (initial) where it included the insert film’s image. Points 2 and 4 show the delaminated area at the edges, while point 3 is at the center.
Figure 9b shows the shortest final crack front of the 3ENF tested CFRP2, where points 5 and 7 were at the edges while point 6 was at the center. The longest path of the crack front at edges was not observed due to difficulty in sectioning the sample without forced opening (intended to preserve the crack front).
Figure 10 shows SEM images of the observed sites within CFRP2. There was no sign of fiber breakage, confirming the analysis that fiber breakage was not the crack initiator. This might indicate that crack initiation started at edges and was initiated by microcracks at the matrix or at matrix-fiber interface. The figures of the damaged zone show that there are hackles formed at the matrix. They are characteristics of Mode II fracture at the matrix [
22,
23]. There was no sign of shear lip formation, an indicator of ductile matrix [
24], thus confirming that the epoxy matrix is of strong and brittle type. Density of hackles is proportional to strain [
22].
Figure 10 location 6 showed only slight difference in density of hackles, and a similar trend was found on locations 5 and 7. However, there was the occurrence of pulled fibers at each edge. These evidenced that the applied shear load induced higher strain at the edges than at the center. Indirectly, it can be deduced that the cracks indeed propagated more at the edges than at the center when CFRP1 was 3ENF tested.
At the final crack front of the CFRP2 sample, in particular at the center, it was apparent that hackles at the center were less rotated than those at the edges (
Figure 10). This evidenced that the edges were more strained compared to the center. However, it cannot be deduced that for 3ENF tested CFRP2, the cracks propagated more at the center, considering the initial crack front was readily curved.
Overall, the fractographs of the 3ENF tested unidirectional CFRP composite sample supported the finding obtained from the micro CT scan. It was found, albeit through low resolution micro CT images, that the crack front profiles of 3ENF tested CFRP1 and CFRP2 are curved, with more propagation occurred at edges compared to at the center. This fractography analysis complements and confirms the finding from the micro CT scan.