Experimental Study on Performance of Steel Fiber-Reinforced Concrete V-Shaped Columns
Abstract
:1. Introduction
2. Experimental Program
2.1. Apparatus
2.2. Mix Design and Materials Properties
2.3. Specimen Preparation
2.4. Test Procedure
2.5. Ductility and Service Stiffness
3. Experimental Results and Discussion
3.1. Fiber Impact on Compressive and Flexural Behaviors
3.1.1. Failure Mode
3.1.2. Load–Displacement and Ductility Behaviors
3.2. Fiber Impact on V-Shaped Column Behaviors
3.2.1. Failure Mode
3.2.2. Load–Displacement Behavior
3.2.3. Ductility and Service Stiffness
3.3. Capacity Evaluation
3.4. Experimental Interaction Diagram (P–M Diagram)
4. Conclusions
- The addition of the MSSFs to concrete mix influences the post-ultimate-load behavior of the specimen tested under a concentric load by softening the descending part of the load–vertical displacement curve and avoiding sudden failure.
- The increase in ductility index due to the addition of MSSF was 79%, and the energy absorption increased by 78%. Thus, the addition of the MSSFs to treat the brittle matter in the specimens under concentric load was very successful.
- Adding MSSF results in an increment in bending capacity of 17% compared with the NRC beam. Adding MSSF to the flexural beams softened the descending part of the load–midspan displacement curve with an increment in ductility index by 9% and the energy absorption λ by 7%.
- The V-shaped column with 30°, regardless of the concrete type (with and without MSSFs), exhibited crushing at legends when the sample reached the ultimate load.
- With an increasing angle of inclination in the V-shaped columns, the ultimate load capacity was decreased by 24%, 23%, and 20% for V-shaped columns with 30°, 60°, and 90° angles of inclination, respectively.
- All SFRC V-shaped columns showed increased relative and horizontal displacements at ultimate load, except the FRC-90 column. This singular behavior resulted from the main cracks of the FRC-90 column, which were vertical on the inclined leg, while for the other V-shaped columns, the main crack was vertical on the horizontal plane.
- The increase of 79% in compressive stiffness was observed from the vertical columns, while the compressive stiffness of the V-shaped columns with 30° and 60° angles of inclination amounted to 19% compared to the NRC specimens. The V-shaped column with a 90° angle showed the lowest percent increase in compression stiffness, of about 9.1%.
- For the deflection at ultimate load for the NSC and FRC specimens, the maximum percentage increase was about 36.5% for the vertical column, while for all V-shape columns, the percentage increase ranged from 20% to 23.5%, and to 17% for the beam. As the angle of the V-shape column increased, the specimens exhibited increased lateral deformation with the increased load. Therefore, the angle between columns significantly influenced the deformation behavior.
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Lomiento, G.; Bonessio, N.; Benzoni, G.; Phillippi, D.; Hegemier, G.A. Capacity Assessment of V-Shaped RC Bridge Bents. J. Bridg. Eng. 2014, 19, 266–280. [Google Scholar] [CrossRef]
- Phillippi, D.J.; Hegemier, G.A. Shear Loading in Two-Column Bridge Bents. ACI Struct. J. 2014, 111, 1497–1508. [Google Scholar] [CrossRef]
- Phillippi, D.J.; Hegemier, G.A. Simplified Two-Column Analytically Based Fiber Model. ACI Struct. J. 2017, 114, 349–359. [Google Scholar] [CrossRef]
- Eid, R.; Cohen, A.; Guma, R.; Ifrach, E.; Levi, N.; Zvi, A. High-Strength Concrete Circular Columns with TRC-TSR Dual Internal Confinement. Buildings 2019, 9, 218. [Google Scholar] [CrossRef] [Green Version]
- Kytinou, V.K.; Chalioris, C.E.; Karayannis, C.G.; Elenas, A. Effect of Steel Fibers on the Hysteretic Performance of Concrete Beams with Steel Reinforcement—Tests and Analysis. Materials 2020, 13, 2923. [Google Scholar] [CrossRef]
- Gribniak, V.; Kaklauskas, G.; Torres, L.; Daniunas, A.; Timinskas, E.; Gudonis, E. Comparative analysis of deformations and tension-stiffening in concrete beams reinforced with GFRP or steel bars and fibers. Comp. Part B Eng. 2013, 50, 158–170. [Google Scholar] [CrossRef]
- Wang, Z.; Wu, J.; Wang, J. Experimental and numerical analysis on effect of fibre aspect ratio on mechanical properties of SRFC. Constr. Build. Mater. 2010, 24, 559–565. [Google Scholar] [CrossRef]
- Toma, A.; Stanila, A.; Stanila, O. The V-shaped Columns. Bul. Ştiinţ. Univ. Politeh. Timiş. 2013, 58, 75–78. [Google Scholar]
- Chalangaran, N.; Farzampour, A.; Paslar, N. Nano Silica and Metakaolin Effects on the Behavior of Concrete Containing Rubber Crumbs. CivilEng 2020, 1, 17. [Google Scholar] [CrossRef]
- Farzampour, A. Compressive behavior of concrete under environmental effects. In Compressive Strength of Concrete; IntechOpen: Rijeka, Croatia, 2019. [Google Scholar]
- Chalangaran, N.; Farzampour, A.; Paslar, N.; Fatemi, H. Experimental Investigation of Sound Transmission Loss in Concrete Containing Recycled Rubber Crumbs; Virginia Tech: Blacksburg, VA, USA, 2021. [Google Scholar]
- Mansouri, I.; Shahheidari, F.S.; Hashemi, S.M.A.; Farzampour, A. Investigation of steel fiber effects on concrete abrasion resistance. Adv. Concr. Constr. 2020, 9, 367–374. [Google Scholar]
- Farzampour, A. Temperature and humidity effects on behavior of grouts. Adv. Concr. Constr. 2017, 5, 659. [Google Scholar]
- Azzawi, R.; Abolmaail, A. Experimental investigation of steel fiber RC hollow columns under eccentric loading. Structures 2020, 24, 456–463. [Google Scholar] [CrossRef]
- Ikponmwosa, E.E.; Salau, M.A. Effect of Short Steel Fibre Reinforcement on Laterized Concrete Columns. J. Sustain. Dev. 2011, 4, 1. [Google Scholar] [CrossRef] [Green Version]
- Al-Tikrite, A.; Hadi, M. Influence of Steel Fibres on the Behaviour of RPC Circular Columns Under Different Loading Conditions. Structures 2018, 14, 111–123. [Google Scholar] [CrossRef] [Green Version]
- Yia, J.; Lia, J. Experimental and numerical study on seismic response of inclined tower legs of cable-stayed bridges during earthquakes. Eng. Struct. 2019, 183, 180–194. [Google Scholar] [CrossRef]
- Tokgoz, S.; Dundar, C. Tests of eccentrically loaded L-shaped section steel fibre high strength reinforced concrete and composite columns. Eng. Struct. 2012, 38, 134–141. [Google Scholar] [CrossRef]
- Teng, Z.-C.; Zhao, T.-J.; Liu, Y. Analysis of the Seismic Performance of a Two-Span Specially Shaped Column Frame. Adv. Civ. Eng. 2019, 2019, 1–14. [Google Scholar] [CrossRef] [Green Version]
- Wang, T.-C.; Zhang, X.-H. Frame property of unequal storey height with specially shaped columns under cyclic loading. J. Central South Univ. Technol. 2010, 17, 1364–1369. [Google Scholar] [CrossRef]
- Wang, T.C.; Lin, H.; Kang, G. Experiment and nonlinear static analysis of RC special-shaped-column frames. J. Tianjin Univ. Sci. Technol. 2006, 39, 1457–1464. (In Chinese) [Google Scholar]
- American Concrete Institute. Building Code Requirements for Structural 678 Concrete and Commentary; ACI 318R-11; American Concrete Institute: Farmington Hills, MI, USA, 2014. [Google Scholar]
- Iraqi Standard Specification No. 45. Aggregate from Natural Sources for Concrete and Construction; Ministry of Planning, Central Organization for Standardization and Quality Control: Baghdad, Iraq, 1984.
- Al-Baghdadi, H.; Al-Merib, F.; Ibrahim, A.; Hassan, R.; Hussein, H. Effects of Coarse Aggregate Maximum Size on Synthetic/Steel Fiber Reinforced Concrete Performance with Different Fiber Parameters. Buildings 2021, 11, 158. [Google Scholar] [CrossRef]
- ASTM A615/A615M-20—Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement; ASTM International: West Conshohocken, PA, USA, 2020.
- EN, B. BS EN 12390-2:2009, Testing Hardened Concrete. Making and Curing Specimens 673 for Strength Tests; British Standard; British Standards Institution: London, UK, 2009. [Google Scholar]
- ASTM C496/C496M-17—Standard Test Method for Splitting Tensile Strength of Cylindrical 671 Concrete Specimens; ASTM International: West Conshohocken, PA, USA, 2017.
- ASTM C78/C78M-18—Standard Test Method for Flexural Strength of Concrete (Using 675 Simple Beam with Third-Point Loading); ASTM International: West Conshohocken, PA, USA, 2018; Volume 676.
- Hassan, R.F.; Jaber, M.H.; Al-Salim, N.H.; Hussein, H.H. Experimental research on torsional strength of synthetic/steel fiber-reinforced hollow concrete beam. Eng. Struct. 2020, 220, 110948. [Google Scholar] [CrossRef]
- Han, J.; Zhao, M.; Chen, J.; Lan, X. Effects of steel fiber length and coarse aggregate maximum size on mechanical properties of steel fiber reinforced concrete. Constr. Build. Mater. 2019, 209, 577–591. [Google Scholar] [CrossRef]
- Al Rikabi, F.T.; Sargand, S.M.; Khoury, I.; Hussein, H.H. Material Properties of Synthetic Fiber–Reinforced Concrete under Freeze-Thaw Conditions. J. Mater. Civ. Eng. 2018, 30, 4018090. [Google Scholar] [CrossRef]
- ASTM International. C192/C192M-13a-Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory; Technical Report; ASTM International: West Conshohocken, PA, USA, 2013. [Google Scholar]
- Hadi, M.N.; Khan, Q.S.; Sheikh, M.N. Axial and flexural behavior of unreinforced and FRP bar reinforced circular concrete filled FRP tube columns. Constr. Build. Mater. 2016, 122, 43–53. [Google Scholar] [CrossRef] [Green Version]
- Hadi, M. Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns. Constr. Build. Mater. 2009, 23, 1102–1108. [Google Scholar] [CrossRef] [Green Version]
- Koçera, M.; Ӧztürk, M.; Arslana, H. Determination of moment, shear and ductility capacities of spiral columns using an artificial neural network. J. Build. Eng. 2019, 26, 100878. [Google Scholar] [CrossRef]
- Pessiki, S.; Pieroni, A. Axial load behavior of large-scale spirally-reinforced highstrength concrete columns. ACI Struct. J. 1997, 94, 304–314. [Google Scholar]
- Saljoughian, A.; Mostofinejad, D. Corner Strip-Batten Technique for FRP-Confinement of Square RC Columns under Eccentric Loading. J. Compos. Constr. 2016, 20, 4015077. [Google Scholar] [CrossRef]
- Huo, J.; Huang, G.; Xiao, Y. Effects of sustained axial load and cooling phase on post-fire behaviour of concrete-filled steel tubular stub columns. J. Constr. Steel Res. 2009, 65, 1664–1676. [Google Scholar] [CrossRef]
- Yang, Y.-F.; Cao, K.; Wang, T.-Z. Experimental behavior of CFST stub columns after being exposed to freezing and thawing. Cold Reg. Sci. Technol. 2013, 89, 7–21. [Google Scholar] [CrossRef]
- Vu, N.S.; Li, B.; Beyer, K. Effective stiffness of reinforced concrete coupling beams. Eng. Struct. 2014, 76, 371–382. [Google Scholar]
- Bhargava, P.; Sharma, U.K.; Kaushik, S.K. Compressive Stress-Strain Behavior of Small Scale Steel Fibre Reinforced High Strength Concrete Cylinders. J. Adv. Concr. Technol. 2006, 4, 109–121. [Google Scholar] [CrossRef] [Green Version]
- Liao, W.-C.; Perceka, W.; Liu, E.-J. Compressive Stress-Strain Relationship of High Strength Steel Fiber Reinforced Concrete. J. Adv. Concr. Technol. 2015, 13, 379–392. [Google Scholar] [CrossRef] [Green Version]
Specimen ID | Material | Specimen Configuration | X (cm) | |
---|---|---|---|---|
NRC-0 | NSC | Column | - | - |
NRC-30 | NSC | V-shape-1 | 36 | 30 |
NRC-60 | NSC | V-shape-2 | 70 | 60 |
NRC-90 | NSC | V-shape-3 | 100 | 90 |
NRC-B | NSC | Beam | - | - |
FRC-0 | SFRC | Column | - | - |
FRC-30 | SFRC | V-shape-1 | 36 | 30 |
FRC-60 | SFRC | V-shape-2 | 70 | 60 |
FRC-90 | SFRC | V-shape-3 | 100 | 90 |
FRC-B | SFRC | Beam | - | - |
Materials and Properties | Amount |
---|---|
Mix water/cement ratio | 0.46 |
MSSF | 1.5% of specimen volume |
Maximum Size Aggregate (mm) | 14 |
Slump (cm) | 8–10 |
Water (kg/m3) | 207 |
Cement (kg/m3) | 450 |
Fine aggregate (kg/m3) | 723 |
Coarse aggregate (kg/m3) | 1010 |
Details | Splitting Tensile (ft) (MPa) | Flexural Strength (ff) (MPa) | Compression Strength (fcu′) (MPa) | Brittleness Ratio |
---|---|---|---|---|
NSC | 2.94 | 3.97 | 32.5 | 8.19 |
FRC | 3.92 | 5.12 | 38.9 | 7.6 |
Specimen ID | NRC-0 | FRC-0 | NRC-B | FRC-B |
---|---|---|---|---|
Yield load (kN) | 84 | 115 | 22 | 27 |
Corresponding axial deformation at yield load (mm) | 1.3 | 0.8 | 3.5 | 4.15 |
Ultimate load (kN) | 137 | 187 | 29 | 34 |
Deformation at ultimate load (mm) | 3.9 | 3.6 | 7.9 | 6.89 |
Post deformation at 85% post ultimate load (mm) | 3.9 | 11.5 | 12.4 | 15.6 |
Ductility index (μ) | 3 | 14.4 | 3.5 | 3.8 |
Energy absorption (λ) | 6.5 | 30.2 | 6.1 | 6.5 |
Specimen ID | Inner Point (kN) | Inner Face (kN) | Outer Face (kN) | Failure Load (kN) |
---|---|---|---|---|
NRC-30 | 142 | 165 | 175 | 220 |
NRC-60 | 12 | 30 | 47 | 70 |
NRC-90 | 5 | 20 | Not appeared | 25 |
FRC-30 | 182 | 213 | 258 | 272 |
FRC-60 | 28 | 47 | 58 | 86 |
FRC-90 | 7 | 12 | 27 | 30 |
Specimen ID | NRC-30 | FRC-30 | NRC-60 | FRC-60 | NRC-90 | FRC-90 |
---|---|---|---|---|---|---|
Relative displacement at ultimate load (mm) | 1.95 | 3.72 | 4.8 | 5.32 | 3.1 | 2.45 |
Horizontal displacement at ultimate load (mm) | 5.02 | 7.45 | 10.32 | 12.3 | 5.1 | 3.85 |
Specimen ID | NRC-30 | FRC-30 | NRC-60 | FRC-60 | NRC-90 | FRC-90 |
---|---|---|---|---|---|---|
Yield load (kN) | 125 | 135 | 48 | 59 | 19 | 21.5 |
Vertical deflection to yield load (mm) | 2.2 | 2.5 | 7.2 | 6.8 | 6.3 | 7.5 |
Ultimate load (kN) | 220 | 272 | 70 | 86 | 25 | 30 |
Vertical deflection to ultimate load (mm) | 11 | 12.9 | 14 | 13.15 | 10.3 | 11.5 |
Post vertical deflection at 85% post ultimate load (mm) | 12.5 | 22 | 18 | 19 | 13 | 21 |
Ductility index μ | 5.7 | 8.8 | 2.5 | 2.8 | 2.1 | 2.8 |
Energy absorption λ | 12 | 20.6 | 4.7 | 5.1 | 3.1 | 4.7 |
Specimen ID | Compression Stiffness Kc (kN/mm) | Flexural Stiffness Kf (kN/mm) | Kc/Kf |
---|---|---|---|
NRC-0 | 93.2 | - | - |
FRC-0 | 166.7 | - | - |
NRC-30 | 76.5 | 45.8 | 1.67 |
FRC-30 | 90.8 | 48.7 | 1.87 |
NRC-60 | 9.1 | 6.8 | 1.34 |
FRC-60 | 11 | 7.9 | 1.39 |
NRC-90 | 4.4 | 2.7 | 1.63 |
FRC-90 | 4.8 | 3 | 1.6 |
NRC-B | - | 7.1 | - |
FRC-B | - | 7.3 | - |
Specimen ID | Yield Load (kN) | Vertical Deflection to Yield Load (mm) | Ultimate Load (kN) | Vertical Deflection to Ultimate Load (mm) | Relative Displacement at Ultimate Load (mm) | Horizontal Displacement at Ultimate Load (mm) | Compression Stiffness Kc (kN/mm) | Flexural Stiffness Kf (kN/mm) |
---|---|---|---|---|---|---|---|---|
NRC-0 | 137 | 3.9 | 137 | 3.9 | - | - | 93.2 | - |
FRC-0 | 165 | 2.92 | 187 | 11.2 | - | - | 166.7 | - |
NRC-30 | 125 | 2.2 | 220 | 11 | 1.95 | 5.02 | 76.5 | 45.8 |
FRC-30 | 135 | 2.5 | 272 | 12.9 | 3.72 | 7.45 | 90.8 | 48.7 |
NRC-60 | 48 | 7.2 | 70 | 14 | 4.8 | 10.32 | 9.1 | 6.8 |
FRC-60 | 59 | 6.8 | 86 | 13.15 | 5.32 | 12.3 | 11 | 7.9 |
NRC-90 | 19 | 6.3 | 25 | 10.3 | 3.1 | 5.1 | 4.4 | 2.7 |
FRC-90 | 21.5 | 7.5 | 30 | 11.5 | 2.45 | 3.85 | 4.8 | 3 |
NRC-B | 22 | 7.9 | 29 | 14 | - | - | - | 7.1 |
FRC-B | 28 | 6.86 | 34 | 15.9 | - | - | - | 7.3 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Hassan, R.F.; Al-Salim, N.H.; Mohammed, N.S.; Hussein, H.H. Experimental Study on Performance of Steel Fiber-Reinforced Concrete V-Shaped Columns. Buildings 2021, 11, 648. https://doi.org/10.3390/buildings11120648
Hassan RF, Al-Salim NH, Mohammed NS, Hussein HH. Experimental Study on Performance of Steel Fiber-Reinforced Concrete V-Shaped Columns. Buildings. 2021; 11(12):648. https://doi.org/10.3390/buildings11120648
Chicago/Turabian StyleHassan, Rafea F., Nabeel H. Al-Salim, Nisreen S. Mohammed, and Husam H. Hussein. 2021. "Experimental Study on Performance of Steel Fiber-Reinforced Concrete V-Shaped Columns" Buildings 11, no. 12: 648. https://doi.org/10.3390/buildings11120648
APA StyleHassan, R. F., Al-Salim, N. H., Mohammed, N. S., & Hussein, H. H. (2021). Experimental Study on Performance of Steel Fiber-Reinforced Concrete V-Shaped Columns. Buildings, 11(12), 648. https://doi.org/10.3390/buildings11120648