Ultimate Bearing Capacity Analysis of Pile Caps with New Socket Connections
Abstract
:1. Introduction
2. Analysis of Influencing Factors on Socket Connections
2.1. Structure Detail and Composition
2.2. Full-Scale Bridge Piers
2.3. Model Specimens
3. Experimental Research
3.1. Specimen Design
3.2. The Test Loading Device and the Loading Process
3.3. Test Results
4. Finite Element Analysis of Specimens
4.1. Establishment and Verification of Model
4.2. Parametric Analysis
4.2.1. Different Configuration Measures
4.2.2. The Influence of the Cap Reinforcement
4.2.3. The Effect of Socket Depth
4.2.4. The Influence of the Thickness of the Base Plate
4.2.5. The Effect of Pile Length
4.2.6. Influence of Friction Coefficient
5. Analysis of Full-Scale Bridge Piers
5.1. Finite Element Modeling and Analysis
5.2. Bending Moment and Axial Force Correlation Analysis
6. The Derivation of Formula
6.1. Force Model Analysis
6.2. Design Formula
6.3. Formula Validation
7. Conclusions
- The use of rough interfaces at the bottom of the pier, U-shaped hanging bars in the bottom groove, high-strength grouting material in the seam, and large-diameter metal corrugated pipes are effective measures to enhance the vertical bearing capacity of the socket cap. Compared with the tradition socket type, the improved socket type can improve the vertical bearing capacity of the cap and can be used for occasions with high vertical bearing capacity requirements.
- In the case of a certain height of the platform, the greater the depth of the socket, the smaller the thickness of the bottom plate. Similarly, the smaller the socket depth, the greater the thickness of the bottom plate. Therefore, there is a negative correlation between the socket depth and the bottom plate thickness, that is, one increases and the other decreases. The purpose of the research is to find a socket depth that can maximize the bearing capacity of the components and reduce the cost under the condition that the height of the cap is fixed. Therefore, it is necessary to select an optimal socket depth according to the force characteristics to meet these two conditions.
- The vertical bearing capacity of the pile cap is mainly provided by shear keys, the bottom plate, and the U-shaped steel bar. The contribution of the three parts is about 40%, 34%, and 26%, respectively.
- The vertical bearing capacity of the pile cap increased with the increase of the diameter of the hanging bars and the longitudinal bars of the bottom plate. With the increase of socket depth, the flexural bearing capacity of the pier increased. When the plate thickness was increased from 25 cm to 45 cm, there was a 21% increase in the vertical bearing capacity. When the thickness of the bottom plate increased to a certain extent, the vertical bearing capacity of the pile cap was greater than that of bridge piers. The vertical bearing capacity of the pile cap was not a weak link. When considering the flexible deformation of the pile, the vertical bearing capacity of the pile cap decreased. When the equivalent pile length increased from 0.2 m to 2.5 m, there was a 12% increase in the vertical bearing capacity.
- When the thickness of the base plate of the cap was 0.8 m and the total height was 1.8 m, the vertical bearing capacity of the precast cap was about 87% of that of the cast-in-place cap. Considering the cost factor, it is finally recommended to select 0.8 m for the thickness of the base plate of the full-scale precast bridge pier scheme in the case.
- This paper proposed an estimation formula for the vertical bearing capacity of the socket cap, which has a certain safety factor and can be used for design reference. Additional experimental research is needed to verify the accuracy of the finite element analysis results and formula calculation in this paper.
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Zhang, Q.; Alam, M.S. State-of-the-art review of seismic-resistant precast bridge columns. J. Bridge Eng. 2020, 25, 03120001. [Google Scholar] [CrossRef]
- Culmo, M.P.; Marsh, L.; Stanton, J. NCHRP Web-Only Document 242: Recommended AASHTO Guide Specifications for ABC Design and Construction; The National Academies Press: Washington, DC, USA, 2018. [Google Scholar]
- Wang, Z.; Qu, H.; Li, T.; Wei, H.; Wang, H.; Duan, H.; Jiang, H. Quasi-static cyclic tests of precast bridge columns with different connection details for high seismic zones. Eng. Struct. 2018, 158, 13–27. [Google Scholar] [CrossRef]
- Khaleghi, B.; Schultz, E.; Seguirant, S.; Marsh, L.; Haraldsson, O.; Eberhard, M.; Stanton, J. Accelerated bridge construction in Washington State: From research to practice. PCI J. 2012, 57, 34–49. [Google Scholar] [CrossRef]
- Han, Y.; Liu, Z.H.; Wang, L.L. Test for influence of socket connection structure on dynamic response of prefabricated pier under vehicle collision. KSCE J. Civ. Eng. 2022, 26, 1188–1202. [Google Scholar] [CrossRef]
- Zeng, Z.; Xu, Y.; Wang, Z.G. Experimental study of the axial bearing capacity of prefabricated pier-cap with socket connection. In Proceedings of the 9th Asia-Pacific Young Researchers and Graduates Symposium, Shanghai, China, 22–25 December 2019. [Google Scholar]
- Xu, Y.; Zeng, Z.; Wan, Z.G. Experimental studies of embedment length of precast bridge pier with socket connection to pile cap. Eng. Struct. 2021, 233, 111906. [Google Scholar] [CrossRef]
- Sadeghian, P.; Fam, A. Bond-slip analytical formulation toward optimal embedment of concrete-filled circular FRP tubes into concrete footings. J. Eng. Mech. 2010, 136, 524–533. [Google Scholar] [CrossRef]
- Kurama, Y.C.; Sritharan, S.; Fleischman, R.B.; Restrepo, J.I.; Henry, R.S.; Cleland, N.M.; Ghosh, S.K.; Bonelli, P. Seismic-resistant precast concrete structures: State of the art. J. Struct. Eng. 2018, 144, 03118001. [Google Scholar] [CrossRef] [Green Version]
- Azizinamini, A. Accelerated bridge construction. J. Bridge Eng. 2020, 25, 02020002. [Google Scholar] [CrossRef]
- Marsh, M.L.; Wernli, M.; Garrett, B.E. NCHRP Report 698: Application of Accelerated Bridge Construction Connections in Moderate-to-High Seismic Regions; The national Academies Press: Washington, DC, USA, 2011. [Google Scholar]
- Haraldsson, O.; Janes, T.; Eberhard, M.; Stanton, J. Seismic Resistance of Socket Connection between Footing and Precast Column. J. Bridge Eng. 2013, 18, 910–919. [Google Scholar] [CrossRef]
- Osanai, Y.; Watanabe, F.; Okamoto, S. Stress transfer mechanism of socket base connections with precast concrete columns. ACI Struct. J. 1996, 93, 266–276. [Google Scholar]
- Canha, R.M.F.; Borja Jaguaribe, K., Jr.; de Cresce EI Debs, A.L.H.; El Debs, M.K. Analysis of the behavior of transverse walls of socket base connections. Eng. Struct. 2009, 31, 788–798. [Google Scholar] [CrossRef]
- Mohebbi, A.; Saiidi, M.S.; Itani, A.M. Shake table studies and analysis of a precast two-column bent with advanced materials and pocket connections. J. Bridge Eng. 2018, 23, 04018046. [Google Scholar] [CrossRef]
- Mohebbi, A.; Saiidi, M.S.; Itani, A. Development and Seismic Evaluation of Pier Systems w/Pocket Connections, CFRP Tendons, and ECC/UHPC Columns; Center for Civil Engineering Earthquake Research, Department of Civil and Environmental Engineering, University of Nevada: Reno, Nevada, 2017. [Google Scholar]
- Wang, Z.Q.; Li, T.T.; Qu, H.Y.; Wei, H.; Li, Y. Seismic performance of precast bridge columns with socket and pocket connections based on quasi-static cyclic tests: Experimental and numerical study. J. Bridge Eng. 2019, 24, 04019105. [Google Scholar] [CrossRef]
- Cheng, Z.; Liu, D.; Li, S.; Wang, J.; Zhang, J. Performance characterization and design recommendations of socket connections for precast columns. Eng. Struct. 2021, 242, 112537. [Google Scholar] [CrossRef]
- Cheng, Z.; Sritharan, S. Outdoor test of a prefabricated column-pile cap-pile system under combined vertical and lateral loads. J. Bridge Eng. 2020, 25, 04020052. [Google Scholar] [CrossRef]
- Zhang, G.D.; Han, Q.; Xu, K.; Du, X.; He, W. Experimental investigation of seismic behavior of UHPC-filled socket precast bridge column-foundation connection with shear keys. Eng. Struct. 2021, 228, 111527. [Google Scholar] [CrossRef]
- Chan, T.K.; Poh, C.K. Behaviour of precast reinforced concrete pile caps. Constr. Build. Mater. 2000, 14, 73–78. [Google Scholar] [CrossRef]
- Cheng, Z.; Sritharan, S. Side shear strength of preformed socket connections suitable for vertical precast members. J. Bridge Eng. 2019, 24, 04019025. [Google Scholar] [CrossRef]
- AASHTO GSCB INTERIM-2003. Guide Specifications for Design and Construction of Segmental Concrete Bridges (Revision 2); American Association of State Highway Transportation Officials: Washington, DC, USA, 1999. [Google Scholar]
- Lai, L. Analysis on Mechanicl Charteristics of Improved Socket Type Bridge Pier and Caps; Shanghai Institute of Technology, Academic Degree of Master of Engineering: Shanghai, China, 2022. [Google Scholar]
- Li, J. Shear Behavior and Continuous Rigid-Frame System of Precast Segmental Bridges in the Fourth Nanjing Yangtze River Bridge; Southeast University, Academic Degree of Master of Engineering: Nanjin, China, 2010. [Google Scholar]
Position | Assembly Method | Reason |
---|---|---|
Bridge piers and caps | Socket type or grout sleeve | The construction requirements are the highest in the unfavorable stress parts such as compression, bending, shear, and torsion, so the pier and cushion cap must be rigidly connected |
Bridge piers and bent cap | Sleeve or Bellows | It has strong adaptability to construction defects, and the defective structure will not collapse because the connection between the pier and the bent cap can be rigid, semi-rigid, or even hinged |
Piers and piers | Sleeve | Meet shear and compression requirements |
Bent caps and caps | Prestressed | There is prestress in the bent cap, and the prestressed type can make full use of the original advantages |
Specimen | Pouring Method | Platform Height/mm | Socket Depth/D | Connection Method | Bottom Plate Thickness/mm |
---|---|---|---|---|---|
S1 | cast-in-place | 750 | none | ||
S2 | prefabricated components | 750 | 0.7 | shear key | 250 |
S7 | 750 | 0.7 | shear key | 0 |
Name | Material Grade | Young’s Modulus | Yield Stress | Tensile Stress | Plastic Strain |
---|---|---|---|---|---|
/GPa | /MPa | /MPa | |||
Concrete | C40 | 32.5 | none | ||
C70 | 39.2 | ||||
Steel | HRB300 | 200 | 300 | 450 | 0.09 |
HRB400 | 200 | 400 | 540 | 0.09 |
U-Shaped Rebar | Shear Key | Bottom Plate | Sum | |
---|---|---|---|---|
Peak load/kN | 2446 | 3859 | 3238 | 9543 |
Proportion | 26% | 40% | 34% | 100% |
Type of Cap | Full-Scale | Reduced Scale1:2 |
---|---|---|
Cast-in-place cap | 39,534 | 9752 |
Precast cap | 28,673 | 7456 |
Calculation Formula | Bottom Plate Thickness/mm | Design Formula Calculated Value/kN | Finite Element Simulation Value/kN (Cracking Load) | Safety Multiple |
---|---|---|---|---|
Specification for Design of Concrete Structures of the scaled model | 150 | 678 | 2860 | 1.26–4.22 |
200 | 971 | 2976 | ||
250 | 1265 | 3163 | ||
350 | 1855 | 3054 | ||
450 | 2453 | 3091 | ||
Design formula of scaled model | 150 | 1809 | 2860 | 1.33–1.6 |
200 | 1894 | 2976 | ||
250 | 1979 | 3163 | ||
350 | 2149 | 3054 | ||
450 | 2322 | 3091 | ||
Full-scale model Design formula | 500 | 7026 | 7962 | 1.13 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Ge, J.; Lai, L.; Liu, S.; Yan, X. Ultimate Bearing Capacity Analysis of Pile Caps with New Socket Connections. Buildings 2022, 12, 2034. https://doi.org/10.3390/buildings12112034
Ge J, Lai L, Liu S, Yan X. Ultimate Bearing Capacity Analysis of Pile Caps with New Socket Connections. Buildings. 2022; 12(11):2034. https://doi.org/10.3390/buildings12112034
Chicago/Turabian StyleGe, Jiping, Luqi Lai, Side Liu, and Xingfei Yan. 2022. "Ultimate Bearing Capacity Analysis of Pile Caps with New Socket Connections" Buildings 12, no. 11: 2034. https://doi.org/10.3390/buildings12112034
APA StyleGe, J., Lai, L., Liu, S., & Yan, X. (2022). Ultimate Bearing Capacity Analysis of Pile Caps with New Socket Connections. Buildings, 12(11), 2034. https://doi.org/10.3390/buildings12112034