Next Article in Journal
Integrated Design and Control of Various Hydrogen Production Flowsheet Configurations via Membrane Based Methane Steam Reforming
Previous Article in Journal
Electrospun Polycaprolactone Fibrous Membranes Containing Ag, TiO2 and Na2Ti6O13 Particles for Potential Use in Bone Regeneration
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electrochemical Properties of Homogeneous and Heterogeneous Anion Exchange Membranes Coated with Cation Exchange Polyelectrolyte

by
Xenia Nebavskaya
1,*,
Veronika Sarapulova
1,
Dmitrii Butylskii
1,
Christian Larchet
2 and
Natalia Pismenskaya
1
1
Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia
2
Institut de Chimie et des Matériaux Paris-Est, UMR7182 CNRS—Université Paris-Est, 2 rue Henri Dunant, 94320 Thiais, France
*
Author to whom correspondence should be addressed.
Membranes 2019, 9(1), 13; https://doi.org/10.3390/membranes9010013
Submission received: 3 December 2018 / Revised: 29 December 2018 / Accepted: 6 January 2019 / Published: 11 January 2019
(This article belongs to the Section Polymeric Membranes)

Abstract

:
Coating ion exchange membranes with polyelectrolyte has been proven to be a cheap way to reduce concentration polarization and increase limiting current (for polyelectrolytes carrying fixed groups of the same sign of charge with respect to the membrane bulk), to create high monovalent selectivity, and to add the function of H+/OH ions generation (for polyelectrolytes bearing fixed groups of the opposite sign of charge with respect to the membrane bulk). In the latter case, the balance between the counterion transport and the H+/OH ions generation is affected by parameters of the substrate and the modifying layer. In this study we investigated the electrochemical characteristics of homogeneous Neosepta AMX-Sb and heterogeneous MA-41P membranes coated with one, two, or three layers of oppositely charged polyelectrolyte (the maximum thickness of each layer was 5 µm). It was found that the limiting current decreased earlier and the generation of H+/OH ions was stronger in the case of the heterogeneous membrane. The shift in the pH of the solution depended more on the generation of H+/OH ions at the modifying layer/solution interface than on the generation at the membrane/modifying layer interface, and in all cases water splitting started in the same range of potential drops over the membrane.

Graphical Abstract

1. Introduction

The modification of ion exchange membrane (IEM) surfaces with a polyelectrolyte layer was first proposed by Sata et al. [1], who aimed to improve monovalent selectivity through the introduction of a selective layer carrying fixed groups oppositely charged with respect to the fixed groups of membrane bulk. In practice, the samples with functional groups of modifying layers being oppositely charged to the groups in membrane bulk became bipolar membranes with two functions: desalination and H+/OH ions generation [2]. The great role in the electrochemical properties of such IEM is played by the bipolar junction between the membrane and the modifying layer, at which the H+/OH ions generation occurs.
Further studies broadened the range of application of layered electrochemical materials. Membrane-coated electrodes attracted interest for various electrochemical applications [3,4,5]. In the case of IEM, for redox flow batteries, layered polyelectrolyte composite membranes showed good conductivity and low permeability to vanadium ions [6], and a thorough review of methods to achieve high monovalent selectivity of IEM in the separation processes (including several techniques for coating surfaces with charged and uncharged layers) was recently published [7]. Surface modification of ion exchange membranes with polyelectrolytes was used for pH correction [8], for suppression of fouling [9,10] or scaling [11], and for facilitation of the electro-osmotic slip of water near the surface [12]. It was shown that excellent monovalent selectivity can be achieved for IEM using layer-by-layer coating with polyelectrolytes carrying functional groups of alternating charges [13,14], or even for multilayers applied at uncharged porous supports [15]. For these systems, very high separation factors and adequate electric resistance were reported. However, several possible additional properties of layered IEM, such as the ability to generate H+ and OH ions, should be taken into account for possible applications.
The balance between the transport of salt ions and the generation of H+/OH ions depends on the thickness of the applied layer. For asymmetric bipolar membranes produced by the pouring and spreading of relatively thick modifying layers, this dependence was studied by Zabolotsky et al. [8], who found that the water splitting increases (and salt ion transport decreases) with the layer thickness. For thinner layers, the details of such dependency are not yet known, hence one of the tasks of our study was to determine the effect of modifying-layer thickness on the electrochemical properties (limiting current density of salt counterion and ability for H+/OH ions generation) of resulting membranes in the cases of applied layers with low thickness.
Another question not yet answered was the role of the electrical heterogeneity of membrane support. Heterogeneous membranes are cheaper than homogeneous ones, hence they can be used for the design of cheaper novel materials with improved monovalent selectivity and reasonable electrochemical properties. What makes the difference between the homogeneous and the heterogeneous membranes in this case is that the appearance of nonconductive zones at the surface of heterogeneous membranes make the current lines concentrated on conductive zones [16]. As a result, the local current density is higher on conductive zones, which causes stronger concentration polarization and water splitting. Modified homogeneous membranes [13] and modified heterogeneous membranes [8] were studied separately, but the differing methods of modification and testing protocols do not allow direct comparison of results. To study the effect of this difference, we compared the properties of two series of membranes based on supporting membranes differing in homogeneity. The homogeneous supporting membrane was produced by the paste method (Neosepta AMX-Sb) and the heterogeneous supporting membrane was produced by hot rolling (MA-41P).

2. Materials and Methods

2.1. Membranes and Materials

All samples in this study were prepared from the stock of commercial MA-41P (Shchekinoazot, Russia) and Neosepta AMX-Sb (Astom, Tokyo, Japan) membranes purchased from their respective companies. Both membranes contained an ion exchange matrix of the same composition, poly(styrene-divinylbenzene) copolymer, which carried quaternary ammonium bases (Table 1). They differed in their degrees of heterogeneity.
Data from manufacturers and from previous studies described the procedures of the commercial production of MA-41P and AMX-Sb as follows: During the production of the MA-41P, a mixture of powdered ion exchanger and powdered polyethylene was hot rolled between two layers of Nylon 6 reinforcing cloth. As determined from analysis of the surface fraction of the ion exchanger (based on scanning electron microscopy visualizations of Russian heterogeneous membranes in top view), only about 28% of the resulting membranes can conduct electrical current, even in a swollen state [17]. During the production of AMX-Sb, a mixture of finely powdered polyvinyl chloride and functionalized monomer was applied to reinforced polyvinyl chloride cloth, then heated for polymerization [18], so that the dimensions of heterogeneities were far smaller than in the case of the MA-41P [19] and, before coating, almost 100% of the commercial AMX-Sb membrane was electrically conductive [20].
Commercial membranes used in this study were chosen based on their broad use for electrodialysis. The AMX-Sb homogeneous anion exchange membrane (AEM) operating in electrodialyzers [23] is recommended by its manufacturer for a number of applications including separation of monovalent ions. In Reference [24], this type of AEM is cited as widely used in ED for food industry applications. The MA-41P belongs to the MA-41 series of membranes, which is currently the standard Russian heterogeneous AEM routinely used both for studies and in industry [25,26,27]. The MA-41P membrane is known for its mechanical stability and durability. Coupled with its low cost, these properties make the MA-41P membrane promising for the production of modified membranes [28].
Prior to modification, the membranes were equilibrated with isopropyl alcohol. The dispersion of Nafion was used for coating. Nafion used in this study was perfluorinated ionomer, which contains sulfonic groups. To produce the modifier, a 5% (wt.) commercial dispersion of ionomer in water and alcohols bought from Sigma-Aldrich was diluted fivefold with isopropyl alcohol. The resulting dispersion was spread to produce the modifying layer as thin as possible (differing here from the approach used to produce the asymmetric bipolar membranes with relatively thick modifying layers [8]) onto the 5 cm × 5 cm samples fixed to glass; the membranes were then left to dry in air for 24 h. For spreading, the selected volume (0.25 mL in this case) was applied at the center of the samples and fixed to glass (which rests at the level surface), then the dispersion was manually spread onto the membrane with a spatula (Figure 1) and left to dry.
Previous preparation of the modified membranes following this protocol showed that the thickness of the single layer applied to homogeneous membranes does not exceed 5 µm [29]. After that, the membranes were soaked in concentrated (6.15 M, or 36%) NaCl solution, and every 2 h the solution was diluted two-fold. After four such dilutions, the membranes were transferred into 0.02 M NaCl solution and left for 16 h.
It should be noted that, according to the row of catalytic activity of functional groups [30], neither sulfonic groups of Nafion nor quaternary ammonium bases of AMX-Sb/MA-41P boost the H+/OH ions generation reaction.
The thicknesses were measured for swollen commercial membranes and swollen modified membranes with a micrometer. However, it was found that the modification did not lead to a detectable change in thickness, and that the thickness of commercial AMX-Sb and all composite membranes based on it were in range of 134 ± 3 µm, while thickness of commercial MA-41P and all composite membranes based on it were in the range of 545 ± 3 µm (Table 1). Visualizations of cross sections of MA-41P membranes modified with a single layer of polyelectrolyte (Figure 1e) showed that the thickness of dry layers applied to heterogeneous membranes was about 1 µm.

2.2. Current–Voltage (I–V) Curves

Current–voltage (I–V) curves of studied samples were obtained using a flow-through 4-chamber cell (Figure 2). In all cases tested, the AEM formed a desalination chamber with a Neosepta CMX cation exchange membrane. On the other side, the concentration chamber was separated from the electrode chamber by the MA-41P membrane. The operating area was 2 cm × 2 cm, the intermembrane distance was 0.65 cm, and the operating solution was 0.02 M NaCl pumped at a flow rate of 0.46 cm/s. The polarizing electrodes were made of polished platinum 2 cm × 2 cm and the measurement electrodes were closed Ag/AgCl electrodes connected to Luggin capillaries, the tips of which were located at both sides of the studied membrane against its geometrical center. The distance from the surface was around 0.5 mm. The setup was laboratory-assembled and based on the setup described in more detail in [31,32], with several changes in equipment.
I–V curves were obtained in galvanodynamic mode. The current density was swept from 0 to 6.0 mA/cm2, increasing stepwise at 2.5 µA/cm2 per second. Autolab PGSTAT N100 was used both to create the current sweep and to register the potential drop over the membrane. The theoretical limiting current density was calculated by the Lévêque equation [33]:
j l i m t h e o r = z 1 C 1 F D h ( T 1 t 1 ) [ 1.47 ( h 2 V 0 L D ) 1 3 0.2 ] ,
where z1 and C1 are the charge and molar concentration of counterion in solution bulk, respectively; F is the Faraday constant; D is the diffusion coefficient of salt in solution; h is the intermembrane distance; T1 and t1 are the counterion transport number in the membrane and solution, respectively; V0 is the linear solution pumping rate; and L is the length of the desalination path. The D value was taken equal to that at infinite dilution and 25 °C, which is 1.61 × 10−9 m2/s. For the experimental conditions, T1 was assumed to be equal to 1 (since the membranes are highly selective for counterions in such dilute solutions, and at currents close to the limiting current density the input of water splitting is found to be negligible), t1 to 0.603, h to 6.3 mm, and L to 2.0 cm. The calculated limiting current density was 3.12 mA/cm2.
To determine such parameters as experimental limiting current density and the current at which the coupled effects of concentration polarization arise, the following procedure was employed:
The I–V curves were built in Δφ vs. j coordinates, where Δφ was the experimental potential difference registered between Luggin capillaries and j was the experimental current density (Figure 3). Then, the tangents were drawn to the initial section of the I–V curve (the so-called ohmic region), to the initial section of the plateau region and to the end of the overlimiting currents region. The slope of the first tangent depends on the resistance of the membrane. It shows if the resistance changed due to modification. The intersection of tangents drawn to the ohmic region and to the plateau region gives the experimental limiting current. The intersection of tangents drawn to the plateau region and to the overlimiting currents region gives the point where the transition to the overlimiting current range occurs.
In all cases, the difference in pH between the outlet and the inlet of the desalination chamber was registered together with the I–V curves with a Mettler Toledo SevenCompact S220 pH meter (Shanghai, China). Before the theoretical limiting current was reached, pH value was recorded each 5 min (starting at the beginning of the experiment at 0 min). When the limiting current was reached and the water dissociation reaction was expected to intensify, the lap between the measurements was reduced to 2 min. Since the cation exchange membrane in all tests was the same (strongly acidic Neosepta CMX), the pH-metry data were used to evaluate the relative rate of generation of H+ and OH ions on the AEM.

3. Results and Discussion

Figure 4 gives the I–V curves of studied membranes. It should be noted that even the experimental limiting current of the commercial MA-41P heterogeneous membrane was lower than the theoretical limiting current calculated by the Lévêque equation. This can be explained by a higher local current density at the conductive zones due to the surface being partially occupied by nonconductive material, leading to higher concentration polarization and a faster decrease of salt concentration near the membrane surface.
Comparison of the I–V curves that were measured for homogeneous and heterogeneous membranes showed that in general the changes that occurred with electrochemical properties (due to their modification with polymer carrying the functional groups oppositely charged to groups in membrane bulk) were similar. However, there were also peculiarities.
Firstly, it can be seen that in all cases the experimental limiting current density decreased with the increasing number of layers. Such changes are typical for monopolar ion exchange membranes transforming into bipolar membranes due to the increasing thickness of the oppositely charged layer [8] when the bipolar junction blocks the transport of salt ions.
Secondly, in all cases, the differential resistance of membranes, which could be determined from the slope of the I–V curve in the underlimiting currents region, did not strongly change with the application of layers. However, the character of changes that occurred with modifications of the AMX-Sb membrane differed from the character of changes that occurred with modifications of the MA-41P membrane. Properties of the MA-41P changed gradually (the experimental limiting currents and currents at which the overlimiting current range starts to decrease step by step with each newly applied layer), while properties of the commercial AMX-Sb and samples modified with one or two layers of polymer only slightly differed, and the significant decline occurred only after three layers were applied (Figure 5).
Data of pH-metry showed how water splitting was balanced in the desalination chamber between a cation and an anion exchange membrane. The H+ ions produced at the AEM and the OH ions produced at the cation exchange membrane entered the desalination chamber, and acidification of desalted solution provided evidence that the reaction occurred more strongly at anion exchange membranes, while alkalification of desalted solution showed that the reaction occurred more strongly at cation exchange membranes [34]. Since the cation exchange membrane (Neosepta CMX) was the same in all measurements, the difference in pH between the exit and the entrance of the desalination chamber could be used to compare the intensity of water splitting at different anion exchange membranes.
In the case of commercial monopolar membranes, it is known [34] that the generation of H+/OH ions occurs only at the membrane/desalted solution boundary. In the case of monopolar membranes modified with polyelectrolyte carrying the fixed groups with the charge opposite to membrane bulk, the reaction can occur both at the substrate membrane/modifying layer (bipolar junction) or at the modifying layer/desalinated solution boundaries (Figure 6). The electrolyte concentration decreases faster at the bipolar junction since the delivery of salt ions to this interface is hindered from both directions by electrostatic repulsion forces, meaning that the limiting state is reached faster at this boundary. This first limiting state corresponds to the experimental limiting current. With further increase of potential drop, two situations are possible: either growing potential drop will cause increased transport of salt ions by the electromigration mechanism (despite counterions for the substrate membrane being co-ions for the modifying layer), or growing potential drop will cause intensive H+/OH ions generation at the bipolar junction.
The experimental pH-metry data are given in Figure 7. Dependences of pH difference are given in Figure 7a,b together with experimental limiting current values, and it can be seen that intensive water splitting started much later than the limiting currents were reached. In these cases, therefore, the bipolar junction did not determine the beginning of H+/OH ions generation. In all cases water splitting started in the same relatively small window of potential drops over the membrane (denoted by empty black boxes in Figure 7c,d), and the corresponding current value decreased only due to increasing resistance from the system. This dependence of critical potential drop on the number of layers shows that the desalted solution/modifying layer boundary plays a more important role in development of H+/OH ions generation.
The registered pH values (Figure 7) show the common trend between the homogeneous and heterogeneous membranes: the H+/OH ions generation increased with the number of applied layers, while water splitting was much stronger in the case of modified membranes based on the heterogeneous MA-41P membrane than modified membranes based on the homogeneous AMX-Sb membrane.
A hypothesis can be suggested regarding the differences in behavior of AMX-Sb and MA-41P. It was previously concluded from the peculiarities of electrochemical properties of the AMX-Sb membrane modified with Nafion that the singular application of modifier leads to formation not of a continuous and even layer, but of island-like structures [29]. This is further supported by the geometrical heterogeneity of the homogeneous membrane produced by Astom, which does not have a flat surface but instead possesses repeating hills and valleys [20,35] (Figure 8), where the modifier might be accumulated in the valleys. Since the application of a second layer does not lead to such big changes in the I–V curve, it might be suggested that, like coating with the first layer, the second-layer coating does not lead to complete continuous coverage, while coating with a third layer might lead to full coverage.
Smaller limiting currents and stronger water splitting found for modified membranes based on MA-41P might be explained by the heterogeneity of MA-41P—according to [17], only about 28% of the surface of MA-41 series membranes is represented by ion exchanger. This causes higher current density at conductive areas and, as a result, higher concentration polarization and more pronounced coupled effects—which in this case, judging by Figure 7, were represented by water splitting. Additional factors that may play a role in the difference are the possible preferable sorption of polyelectrolyte on the grains of ion exchanger (due to electrostatic interaction between the oppositely charged fixed groups) and lessened sorption on (uncharged) polyethylene. This would cause the thickening of the layer on the conductive zones in comparison with a homogeneous surface, meaning that such materials might benefit from a decrease in the amount of added modifier.

4. Conclusions

It was shown that spreading one or two thin layers of polymer, with functional groups oppositely charged with respect to the ones in membrane bulk, onto the surface of commercial homogeneous AMX-Sb membrane resulted in the creation of new membranes with resistance and limiting current comparable with the original one. As such, this method is suitable for the creation of materials that combine good transport properties of supporting membrane with monovalent selectivity, due to the oppositely charged layer that was applied. The application of a larger number of layers or the use of heterogeneous membrane led to a decrease of the limiting current and hastening of the onset of overlimiting mode, accompanied by growing H+/OH ions generation. In all cases, the H+/OH ions generation started in the same range of potential drops and this reaction was more active at the external (modifying layer/desalted solution) boundary than at the internal (modifying layer/substrate membrane) boundary. It was found that H+/OH ions generation was stronger, and that the limiting current decreased more readily, in the case of a heterogeneous membrane. Such peculiarities would require special attention if the heterogeneous membranes were to be used for the production of novel modified membranes.

Author Contributions

Conceptualization, X.N.; Methodology, X.N.; Validation, V.S., D.B., and N.P.; Formal Analysis, X.N.; Investigation, V.S. and D.B.; Resources, C.L. and N.P.; Data Curation, X.N.; Writing—Original Draft Preparation, X.N.; Writing—Review & Editing, C.L. and N.P.; Visualization, X.N.; Supervision, C.L. and N.P.; Project Administration, X.N.; Funding Acquisition, X.N. and C.L. All authors have approved the final article.

Funding

This research was funded by CNRS and RFBR grant number 18-58-16008_NCNIL_a.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Sata, T.; Izuo, R.; Mizutani, Y.; Yamane, R. Transport properties of ion-exchange membranes in the presence of surface active agents. J. Colloid Interface Sci. 1972, 40, 317–328. [Google Scholar] [CrossRef]
  2. Zabolotskii, V.; Sheldeshov, N.; Melnikov, S. Heterogeneous bipolar membranes and their application in electrodialysis. Desalination 2014, 342, 183–203. [Google Scholar] [CrossRef]
  3. Lin, Y.; Li, H.; Liu, C.; Xing, W.; Ji, X. Surface-modified Nafion membranes with mesoporous SiO2 layers via a facile dip-coating approach for direct methanol fuel cells. J. Power Sources 2008, 185, 904–908. [Google Scholar] [CrossRef]
  4. Esposito, D.V. Membrane-Coated Electrocatalysts—An Alternative Approach to Achieving Stable and Tunable Electrocatalysis. ACS Catal. 2018, 8, 457–465. [Google Scholar] [CrossRef]
  5. Labrador, N.Y.; Songcuan, E.L.; De Silva, C.; Chen, H.; Kurdziel, S.J.; Ramachandran, R.K.; Detavernier, C.; Esposito, D.V. Hydrogen Evolution at the Buried Interface between Pt Thin Films and Silicon Oxide Nanomembranes. ACS Catal. 2018, 8, 1767–1778. [Google Scholar] [CrossRef]
  6. Luo, Q.; Zhang, H.; Chen, J.; You, D.; Sun, C.; Zhang, Y. Preparation and characterization of Nafion/SPEEK layered composite membrane and its application in vanadium redox flow battery. J. Membr. Sci. 2008, 325, 553–558. [Google Scholar] [CrossRef]
  7. Luo, T.; Abdu, S.; Wessling, M. Selectivity of ion exchange membranes: A review. J. Membr. Sci. 2018. [Google Scholar] [CrossRef]
  8. Zabolotskii, V.; Sheldeshov, N.; Melnikov, S. Effect of cation-exchange layer thickness on electrochemical and transport characteristics of bipolar membranes. J. Appl. Electrochem. 2013, 43, 1117–1129. [Google Scholar] [CrossRef]
  9. Park, J.-S.; Lee, H.-J.; Choi, S.-J.; Geckeler, K.E.; Cho, J.; Moon, S.-H. Fouling mitigation of anion exchange membrane by zeta potential control. J. Colloid Interface Sci. 2003, 259, 293–300. [Google Scholar] [CrossRef]
  10. Mulyati, S.; Takagi, R.; Fujii, A.; Ohmukai, Y.; Maruyama, T.; Matsuyama, H. Improvement of the antifouling potential of an anion exchange membrane by surface modification with a polyelectrolyte for an electrodialysis process. J. Membr. Sci. 2012, 417–418, 137–143. [Google Scholar] [CrossRef]
  11. Andreeva, M.A.; Gil, V.V.; Pismenskaya, N.D.; Dammak, L.; Kononenko, N.A.; Larchet, C.; Grande, D.; Nikonenko, V.V. Mitigation of membrane scaling in electrodialysis by electroconvection enhancement, pH adjustment and pulsed electric field application. J. Membr. Sci. 2018, 549. [Google Scholar] [CrossRef]
  12. Urtenov, M.K.; Uzdenova, A.M.; Kovalenko, A.V.; Nikonenko, V.V.; Pismenskaya, N.D.; Vasil’eva, V.I.; Sistat, P.; Pourcelly, G. Basic mathematical model of overlimiting transfer enhanced by electroconvection in flow-through electrodialysis membrane cells. J. Membr. Sci. 2013, 447, 190–202. [Google Scholar] [CrossRef]
  13. White, N.; Misovich, M.; Yaroshchuk, A.; Bruening, M.L. Coating of Nafion membranes with polyelectrolyte multilayers to achieve high monovalent/divalent cation electrodialysis selectivities. ACS Appl. Mater. Interfaces 2015, 7, 6620–6628. [Google Scholar] [CrossRef] [PubMed]
  14. Abdu, S.; Martí-Calatayud, M.C.; Wong, J.E.; García-Gabaldón, M.; Wessling, M. Layer-by-layer modification of cation exchange membranes controls ion selectivity and water splitting. ACS Appl. Mater. Interfaces 2014, 6, 1843–1854. [Google Scholar] [CrossRef] [PubMed]
  15. Cheng, C.; Yaroshchuk, A.; Bruening, M.L. Fundamentals of selective ion transport through multilayer polyelectrolyte membranes. Langmuir 2013, 29, 1885–1892. [Google Scholar] [CrossRef] [PubMed]
  16. Rubinstein, I.; Zaltzman, B.; Pundik, T. Ion-exchange funneling in thin-film coating modification of heterogeneous electrodialysis membranes. Phys. Rev. E 2002, 65, 1–10. [Google Scholar] [CrossRef] [PubMed]
  17. Volodina, E.; Pismenskaya, N.; Nikonenko, V.; Larchet, C.; Pourcelly, G. Ion transfer across ion-exchange membranes with homogeneous and heterogeneous surfaces. J. Colloid Interface Sci. 2005, 285, 247–258. [Google Scholar] [CrossRef]
  18. Mizutani, Y. Structure of ion exchange membranes. J. Membr. Sci. 1990, 49, 121–144. [Google Scholar] [CrossRef]
  19. Garcia-Vasquez, W.; Ghalloussi, R.; Dammak, L.; Larchet, C.; Nikonenko, V.; Grande, D. Structure and properties of heterogeneous and homogeneous ion-exchange membranes subjected to ageing in sodium hypochlorite. J. Membr. Sci. 2014, 452, 104–116. [Google Scholar] [CrossRef]
  20. Mareev, S.A.; Butylskii, D.Y.; Pismenskaya, N.D.; Larchet, C.; Dammak, L.; Nikonenko, V.V. Geometrical heterogeneity of homogeneous ion-exchange Neosepta membranes. J. Membr. Sci. 2018, 563, 768–776. [Google Scholar] [CrossRef]
  21. Pismenskaya, N.D.; Nikonenko, V.V.; Melnik, N.A.; Shevtsova, K.A.; Belova, E.I.; Pourcelly, G.; Cot, D.; Dammak, L.; Larchet, C. Evolution with time of hydrophobicity and microrelief of a cation-exchange membrane surface and its impact on overlimiting mass transfer. J. Phys. Chem. B 2012, 116, 2145–2161. [Google Scholar] [CrossRef]
  22. Monopolar Membranes-Innovative Company Shchekinoazot Ltd. Available online: http://www.azotom.ru/monopolyarnye-membrany/ (accessed on 5 May 2018).
  23. Ghalloussi, R.; Garcia-Vasquez, W.; Bellakhal, N.; Larchet, C.; Dammak, L.; Huguet, P.; Grande, D. Ageing of ion-exchange membranes used in electrodialysis: Investigation of static parameters, electrolyte permeability and tensile strength. Sep. Purif. Technol. 2011, 80, 270–275. [Google Scholar] [CrossRef]
  24. Garcia-Vasquez, W.; Dammak, L.; Larchet, C.; Nikonenko, V.; Pismenskaya, N.; Grande, D. Evolution of anion-exchange membrane properties in a full scale electrodialysis stack. J. Membr. Sci. 2013, 446, 255–265. [Google Scholar] [CrossRef]
  25. Vasil’eva, V.I.; Zhil’tsova, A.V.; Malykhin, M.D.; Zabolotskii, V.I.; Lebedev, K.A.; Chermit, R.K.; Sharafan, M.V. Effect of the chemical nature of the ionogenic groups of ion-exchange membranes on the size of the electroconvective instability region in high-current modes. Russ. J. Electrochem. 2014, 50, 134–143. [Google Scholar] [CrossRef]
  26. Zabolotskii, V.I.; Chermit, R.K.; Sharafan, M.V. Mass transfer mechanism and chemical stability of strongly basic anion-exchange membranes under overlimiting current conditions. Russ. J. Electrochem. 2014, 50, 38–45. [Google Scholar] [CrossRef]
  27. Melnikov, S.; Sheldeshov, N.; Zabolotsky, V.; Loza, S.; Achoh, A. Pilot scale complex electrodialysis technology for processing a solution of lithium chloride containing organic solvents. Sep. Purif. Technol. 2017, 189, 74–81. [Google Scholar] [CrossRef]
  28. Kniaginicheva, E.; Pismenskaya, N.; Melnikov, S.; Belashova, E.; Sistat, P.; Cretin, M.; Nikonenko, V. Water splitting at an anion-exchange membrane as studied by impedance spectroscopy. J. Membr. Sci. 2015, 496. [Google Scholar] [CrossRef]
  29. Nebavskaya, K.A.; Sarapulova, V.V.; Sabbatovskiy, K.G.; Sobolev, V.D.; Pismenskaya, N.D.; Sistat, P.; Cretin, M.; Nikonenko, V.V. Impact of ion exchange membrane surface charge and hydrophobicity on electroconvection at underlimiting and overlimiting currents. J. Membr. Sci. 2017, 523, 36–44. [Google Scholar] [CrossRef]
  30. Zabolotskii, V.I.; Sharafan, M.V.; Shel’deshov, N.V. Influence of the nature of membrane ionogenic groups on water dissociation and electrolyte ion transport: A rotating membrane disk study. Russ. J. Electrochem. 2008, 44, 1127–1134. [Google Scholar] [CrossRef]
  31. Belova, E.I.; Lopatkova, G.Y.; Pismenskaya, N.D.; Nikonenko, V.V.; Larchet, C.; Pourcelly, G. Effect of anion-exchange membrane surface properties on mechanisms of overlimiting mass transfer. J. Phys. Chem. B 2006, 110, 13458–13469. [Google Scholar] [CrossRef] [PubMed]
  32. Korzhova, E.; Pismenskaya, N.; Lopatin, D.; Baranov, O.; Dammak, L.; Nikonenko, V. Effect of surface hydrophobization on chronopotentiometric behavior of an AMX anion-exchange membrane at overlimiting currents. J. Membr. Sci. 2016, 500, 161–170. [Google Scholar] [CrossRef]
  33. Newman, J.; Thomas-Alyea, K.E. Electrochemical Systems; John Wiley & Sons: Hoboken, NJ, USA, 2004; ISBN 0471477567. [Google Scholar]
  34. Zabolotskii, V.I.; Shel’deshov, N.V.; Gnusin, N.P. Dissociation of water molecules in systems with ion-exchange membranes. Russ. Chem. Rev. 1988, 57, 801–808. [Google Scholar] [CrossRef]
  35. Güler, E.; van Baak, W.; Saakes, M.; Nijmeijer, K. Monovalent-ion-selective membranes for reverse electrodialysis. J. Membr. Sci. 2014, 455, 254–270. [Google Scholar] [CrossRef]
Figure 1. Sketch of the process of modification (ad) and fragments of SEM images of resulting membranes. (a) The commercial membrane to be subjected to modification (the sketch illustrates the case of AMX-Sb); (b) the modifying dispersion is applied; (c) it is manually spread with a spatula; (d) the solvent evaporates, leaving the relatively thin modifying layer. (e) A fragment of an SEM image portraying a cross section of MA-41P membrane modified with one layer of polyelectrolyte; (f) A fragment of an SEM image showing a top view of the same membrane.
Figure 1. Sketch of the process of modification (ad) and fragments of SEM images of resulting membranes. (a) The commercial membrane to be subjected to modification (the sketch illustrates the case of AMX-Sb); (b) the modifying dispersion is applied; (c) it is manually spread with a spatula; (d) the solvent evaporates, leaving the relatively thin modifying layer. (e) A fragment of an SEM image portraying a cross section of MA-41P membrane modified with one layer of polyelectrolyte; (f) A fragment of an SEM image showing a top view of the same membrane.
Membranes 09 00013 g001aMembranes 09 00013 g001b
Figure 2. Principal scheme of the flow-through four-chamber electrodialysis cell (1) with an anion exchange membrane (AEM) under study (A*); auxiliary cation exchange (C) and anion exchange (A) membranes; tanks with 0.02 M NaCl solutions (2,3); Luggin capillaries (4) with Ag/AgCl electrodes (5); an Autolab PGSTAT N100 power source/voltmeter (6); and a pH-sensitive electrode (7) connected to a Mettler Toledo SevenCompact S220 pH meter (8). Adapted from [32].
Figure 2. Principal scheme of the flow-through four-chamber electrodialysis cell (1) with an anion exchange membrane (AEM) under study (A*); auxiliary cation exchange (C) and anion exchange (A) membranes; tanks with 0.02 M NaCl solutions (2,3); Luggin capillaries (4) with Ag/AgCl electrodes (5); an Autolab PGSTAT N100 power source/voltmeter (6); and a pH-sensitive electrode (7) connected to a Mettler Toledo SevenCompact S220 pH meter (8). Adapted from [32].
Membranes 09 00013 g002
Figure 3. Determination of the experimental limiting current and the current at which the coupled effects of concentration polarization arise. The resistance of the membrane can also be determined from the slope of the tangent drawn to the initial part of the curve.
Figure 3. Determination of the experimental limiting current and the current at which the coupled effects of concentration polarization arise. The resistance of the membrane can also be determined from the slope of the tangent drawn to the initial part of the curve.
Membranes 09 00013 g003
Figure 4. I–V curves of the homogeneous AMX-Sb membrane and its modifications (a) and the heterogeneous MA-41P membrane and its modifications (b). Arrows show the increased number of changes occurring with the additional layers of Nafion applied. The dashed line shows the theoretical limiting current calculated by the Lévêque equation. Numerals denote the number of applied layers ranging from zero (no coating, i.e., the commercial membrane) to three.
Figure 4. I–V curves of the homogeneous AMX-Sb membrane and its modifications (a) and the heterogeneous MA-41P membrane and its modifications (b). Arrows show the increased number of changes occurring with the additional layers of Nafion applied. The dashed line shows the theoretical limiting current calculated by the Lévêque equation. Numerals denote the number of applied layers ranging from zero (no coating, i.e., the commercial membrane) to three.
Membranes 09 00013 g004
Figure 5. Dependence of experimental limiting current densities ( i l i m e x p , circles) and current densities of transition to the overlimiting current range (icoupled, squares) on the number of applied layers of polyelectrolyte for AMX-Sb (a) and MA-41P (b).
Figure 5. Dependence of experimental limiting current densities ( i l i m e x p , circles) and current densities of transition to the overlimiting current range (icoupled, squares) on the number of applied layers of polyelectrolyte for AMX-Sb (a) and MA-41P (b).
Membranes 09 00013 g005
Figure 6. Limiting states reached at the commercial membrane (a), at the modifying layer/substrate membrane boundary of the modified membrane (b) and at the modifying layer/desalted solution boundary of the modified membrane (c). Pink zone denotes the substrate membrane, DBL denotes the (depleted) diffusion boundary layer and ML denotes the modifying layer. Black lines show the concentration profile of salt and grey lines show the fluxes of salt ions.
Figure 6. Limiting states reached at the commercial membrane (a), at the modifying layer/substrate membrane boundary of the modified membrane (b) and at the modifying layer/desalted solution boundary of the modified membrane (c). Pink zone denotes the substrate membrane, DBL denotes the (depleted) diffusion boundary layer and ML denotes the modifying layer. Black lines show the concentration profile of salt and grey lines show the fluxes of salt ions.
Membranes 09 00013 g006
Figure 7. Dependence of the difference in pH between the exit and entrance of the desalination chamber formed by CMX cation exchange membranes and AEMs based on AMX-Sb (a,c) and MA-41P (b,d) on current density (a,b) or potential drop over the membrane (c,d). Crosses show the approximations of pH made for experimental limiting current densities based on pH values registered for the two closest current densities. Squares denote the commercial membranes, diamonds represent the membranes with one layer of coating, triangles represent the membranes with two layers of coating, and circles represent the membranes with three layers of coating.
Figure 7. Dependence of the difference in pH between the exit and entrance of the desalination chamber formed by CMX cation exchange membranes and AEMs based on AMX-Sb (a,c) and MA-41P (b,d) on current density (a,b) or potential drop over the membrane (c,d). Crosses show the approximations of pH made for experimental limiting current densities based on pH values registered for the two closest current densities. Squares denote the commercial membranes, diamonds represent the membranes with one layer of coating, triangles represent the membranes with two layers of coating, and circles represent the membranes with three layers of coating.
Membranes 09 00013 g007aMembranes 09 00013 g007b
Figure 8. Cross section of swollen AMX-Sb membrane. Adapted from [20].
Figure 8. Cross section of swollen AMX-Sb membrane. Adapted from [20].
Membranes 09 00013 g008
Table 1. Properties of AMX-Sb and MA-41P commercial substrate membranes.
Table 1. Properties of AMX-Sb and MA-41P commercial substrate membranes.
PropertyAMX-SbMA-41P
Ion exchangerpoly(styrene-divinylbenzene) copolymer which carries quaternary ammonium bases
Diameter of ion exchange grainscontinuous phase5–40 µm [17]
Reinforcing materialPVC grains up to 100 nm in diameter [21] *; PVC clothcontinuous phase of PE; Nylon 6 cloth [22]
Ion exchange capacity, mM/g (swollen sample)1.28 ± 0.051.25 ± 0.05
Thickness, µm (swollen sample)134 ± 3545 ± 3
Resistance in 0.02 M NaCl solution (calculated from current–voltage curves), Ohm4652
* From visualization of the surface of cation exchange membranes prepared by the same method.

Share and Cite

MDPI and ACS Style

Nebavskaya, X.; Sarapulova, V.; Butylskii, D.; Larchet, C.; Pismenskaya, N. Electrochemical Properties of Homogeneous and Heterogeneous Anion Exchange Membranes Coated with Cation Exchange Polyelectrolyte. Membranes 2019, 9, 13. https://doi.org/10.3390/membranes9010013

AMA Style

Nebavskaya X, Sarapulova V, Butylskii D, Larchet C, Pismenskaya N. Electrochemical Properties of Homogeneous and Heterogeneous Anion Exchange Membranes Coated with Cation Exchange Polyelectrolyte. Membranes. 2019; 9(1):13. https://doi.org/10.3390/membranes9010013

Chicago/Turabian Style

Nebavskaya, Xenia, Veronika Sarapulova, Dmitrii Butylskii, Christian Larchet, and Natalia Pismenskaya. 2019. "Electrochemical Properties of Homogeneous and Heterogeneous Anion Exchange Membranes Coated with Cation Exchange Polyelectrolyte" Membranes 9, no. 1: 13. https://doi.org/10.3390/membranes9010013

APA Style

Nebavskaya, X., Sarapulova, V., Butylskii, D., Larchet, C., & Pismenskaya, N. (2019). Electrochemical Properties of Homogeneous and Heterogeneous Anion Exchange Membranes Coated with Cation Exchange Polyelectrolyte. Membranes, 9(1), 13. https://doi.org/10.3390/membranes9010013

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop