Review

Electrospinning-Based Biosensors for Health Monitoring

1
School of Mechanical and Power Engineering, Nanjing Tech University, Nanjing 211800, China
2
Wuhu Innovation New Materials Co., Ltd., Wuhu 241080, China
3
Department of Minerals and Materials Engineering, University of Mines and Technology, Tarkwa 03123, Ghana
*
Author to whom correspondence should be addressed.
Biosensors 2022, 12(10), 876; https://doi.org/10.3390/bios12100876
Submission received: 8 September 2022 / Revised: 2 October 2022 / Accepted: 7 October 2022 / Published: 15 October 2022
(This article belongs to the Special Issue Nanofiber-Based Biosensors)

Abstract

:
In recent years, many different biosensors are being used to monitor physical health. Electrospun nanofiber materials have the advantages of high specific surface area, large porosity and simple operation. These properties play a vital role in biosensors. However, the mechanical properties of electrospun nanofibers are poor relative to other techniques of nanofiber production. At the same time, the organic solvents used in electrospinning are generally toxic and expensive. Meanwhile, the excellent performance of electrospun nanofibers brings about higher levels of sensitivity and detection range of biosensors. This paper summarizes the principle and application of electrospinning technology in biosensors and its comparison with other technologies.

1. Introduction

Globally, it has been observed that improvement in standards of living has also caused the rise of diseases. Biosensors that can monitor our physical health in real time are particularly important. Electrospinning technology has developed rapidly in recent years, and there are several nanofiber membranes that can be used in biosensors. The biosensor has high biocompatibility, good flexibility, remarkable mechanical properties and high sensitivity. For example, biosensors can assess the activity of enzymes in the body to determine the health of stem cells [1]. In recent years, such biosensors and bioelectronics devices that can monitor human health have developed rapidly. However, poor stability and short life span are the main problems in the current development of biosensors [2].
With the continuous advancement of current technology, there are many manufacturing methods for nanofiber membranes, with electrospinning being the easiest and relatively low-cost method. The nanofiber membrane made by electrospinning can form a typical network structure with high surface area and high porosity [3]. The process parameters can be modified to change the morphology and performance of the fiber membrane [4]. Due to these outstanding features, electrospun nanofiber membranes are more applicable in biosensors [5]. Figure 1 shows the main development history of biosensors. This paper reviews the principles and applications of electrospinning in biosensors.

2. Electrospinning

2.1. Principle of Electrospinning

Electrospinning is a high-throughput technology that can produce nanofiber membranes with controllable fiber orientation [21]. In the whole working process, the Taylor cone formed by the solution is stretched by the electrostatic force to form a jet. When the jet is flying in the air, the solvent evaporates and the final solute is deposited on the receiving plate to form nanofibers. Figure 2 is a schematic diagram of the working principle of electrospinning [22,23]. The whole electrospinning equipment mainly includes three parts: a high voltage supply device, an injector and a receiving board. However, different requirements for nanofibers may lead to changes in one or several pieces of equipment. The change of the equipment is only to get the nanofibers needed while maintaining the working principle.
The influencing factors of electrospinning mainly include: solution concentration and viscosity, voltage intensity, receiving distance, air humidity and temperature. The viscosity and concentration of the solution play an important role in the morphology and performance of the fiber [24]. Voltage and receiving distance directly affect the thickness of the fiber [25]. The humidity and temperature of the air affect the volatilization of the solvent during the jet flight, which ultimately affects the formation of the fibers [26].

2.2. Types of Nanofibers

Different parameters and methods of electrospinning lead to different morphology of nanofibers. For example, core-shell nanofibers can be obtained by coaxial electrospinning. Different kinds of nanofibers have different characteristics such as oriented nanofibers with high axial mechanical properties and good dimensional stability. High porosity and large specific surface area are key properties that contribute to a successful biosensor, hence the wide use of electrospun nanofibers [27]. Meanwhile, biosensors based on nanofibers have the advantages of high responsiveness, high sensitivity, wide detection object and cost effectiveness [28]. Figure 3 shows the morphological characteristics of different kinds of nanofibers.

2.3. Preparation and Characteristics of Nanofibers

The types of nanofibers are described above and the preparation techniques used for different nanofibers are also different. The preparation technology and characteristics of different fibers are described in detail below.
  • Randomly distributed nanofibers: The preparation of such fibers is the simplest form by direct drawing of the instabilities of the jet. This results in a relatively small range of applications and poor mechanical properties for such fibers. However, the advantage is that the preparation is simple and there is no complicated process.
  • Aligned nanofibers: This fiber is obtained by suppressing the instability of the jet on the basis of randomly distributed nanofibers. This makes the fibers have the advantages of high axial mechanical strength, good dimensional stability and high application value in tissue engineering, composite reinforcement, electrical and optical fields. However, due to the different methods used, the collection speed may be slow and the amount of fibers is relatively small.
  • Core-shell nanofibers: Fibers of this structure are mostly obtained by coaxial electrospinning devices. Core-shell structured nanofibers solve the problem that some materials are not spinnable. Core-shell structured nanofibers solve the problem that some materials are not spinnable. This also makes this fiber widely used in biomedical fields such as drug release systems, tissue engineering scaffolds, drug-loaded medical dressings and sutures.
  • Multispace nanofibers: The preparation of such fibers is mostly used to induce phase separation. For example, solvent evaporation and heating can induce phase separation to form multispace nanofibers. This fiber is characterized by a substantial increase in the specific surface area of the fiber.
  • Pine-needle nanofibers: Such fibers are formed based on randomly distributed nanofibers. Then, other materials are generally grown on randomly distributed fibers by hydrothermal method.
  • Patterned nanofibers: This fiber is obtained by changing the shape, movement mode and material of the collecting device. Its physical and chemical properties are basically the same as those of disordered fibers.
  • Cobweb nanofibers: This fiber is a two-dimensional mesh fiber membrane material with ultrafine electrospun fibers as a scaffold. It has the advantages of large specific surface area, good adsorption and stable mechanical properties.
  • Hollow nanofibers: This fiber is obtained on the basis of the core-shell structure fiber. Such fibers are generally obtained by coaxial electrospinning with a soluble or volatile substance as the core layer and a polymer solution as the shell layer and then removing the core layer by dissolving or heating. The disadvantage is that the production efficiency is relatively low.

3. The Principle and Characteristics of Biosensors

3.1. Working Principle

A biosensor is mainly composed of a biosensor and signal transducer. The main function of the biosensor is to select the substance to be measured. The main function of signal transducers is to convert the chemical effects generated by the interaction between the biological components and measured substances into electrical signals that can be considered as output [37]. Thus, it works in two steps. Firstly, biological substances with molecular recognition function are coated and fixed on the carrier by technical means (such as electrospinning) to form a functional membrane. Secondly, in the working process, the biological substances react with the measured substances and then carry out signal conversion through the signal transmitter [38]. Figure 4 shows the main schematic diagram of the biosensor.
Electrospinning is also widely used in the field of biosensors. This is because the nanofiber film obtained by electrospinning has a high specific surface area. This enables more biological elements to be loaded on the fiber surface, which greatly improves its sensitivity. This is why electrospinning technology has been widely used in the field of biosensors in recent years. Table 1 lists several common biological elements and loading methods.

3.2. Characteristics of Biosensors

There are four main characteristics of biosensors (selectivity, sensitivity, reproducibility and stability) [44]. Selectivity is an important characteristic to be considered when biosensors select receptors. Only when biological elements interact with receptors can they produce positive effects. Since general biological samples contain a variety of biological information, selectivity is particularly important for sensors. Sensitivity is one of the important indicators to measure the quality of sensors. High-sensitivity sensors can respond to small fluctuations in sample concentration. Reproducibility can also be understood as the accuracy of the sensor. Sensors with high reproducibility can get the same results under multiple measurements. Stability is an important characteristic to ensure that the sensor can be used for a long time [45].

4. Application of Electrospinning in Biosensors

In recent years, the development of electrospinning technology has been very rapid and the fields of application are expanding. Compared with other technologies, electrospinning is relatively simple and versatile [46]. Therefore, electrospinning technology is widely used in the fields of biosensors. However, medical care has been mostly passive in recent times, with patients not seeing a doctor until they experience significant discomfort or symptoms [47]. This is very likely to cause aggravation of the disease. With the development of biosensors getting better and better, the probability of predicting the occurrence of diseases in advance is gradually increasing [48]. The biosensor can sense the biological information of the human body to determine whether there is a possibility of disease. It can also test human movement, heart rate, sweat, sleep, blood sugar, blood pressure and temperature [49]. Biosensors can also be used as a bandage. According to the principle of sensor device detection, they can be classified as: piezoelectric biosensor, electrochemical biosensor, thermal biosensor, optical biosensor, acoustic channel biosensor, field effect tube biosensor and mediator biosensor. Electrospinning technology is widely used in the first four sensors but rarely applied in the latter three. So this paper mainly introduces the first four biosensors. Figure 5 exemplifies a specific application of electrospinning-based biosensors.

4.1. Piezoelectric Biosensor

Piezoelectric biosensors are often used to test whether the heart rate, pulse and limb movements are normal. The detection principle is based on the deformation of the sensor to drive the resistance to change to reflect the health of the body. For example, when detecting a pulse, the resistance response is normally stable and fluctuating. However, if the resistance response suddenly appears abnormal, it means that the pulse beat is abnormal. The same is true when detecting body movement.

4.1.1. Monitoring Heart Rate

Heart rate is a very important indicator of the human body and its abnormality can threaten life. Therefore, it is particularly important to invent a sensor that can monitor heart rate in real time. There are many sports bracelets on the market that can monitor heart rate in real time. However, the stability and sensitivity of this equipment are generally not high enough to reflect abnormal conditions in time [56]. This greatly limits its application in clinical medicine, and the clinical demand for low-cost and easy-to-use sensors has not yet been met [57]. The low-cost and easy operation of electrospinning greatly expands the application of this technology in the field of biosensors.
In recent years, the development of sensors for monitoring heart rate has advanced rapidly. Mainly manifested in increased functions, increased sensitivity and ease of production [58]. Studies have shown that many cardiovascular parameters can be obtained from heart rate, which provides a basis for early treatment of diseases [59]. Piezoelectric biosensors can respond well to heart rate conditions. The principle is to deform the dielectric in the sensor through vibration and then output a visual electrical signal. Li et al. [60] created a highly sensitive pressure sensor to monitor heart rate. Figure 6 shows the principle diagram of this sensor and the heart rate fluctuations. The electronic skin consists of Cu–Ni-plated fine-knit polyester fabric attached to both sides of the composite nanofibers to prepare the top and bottom electrodes. The electrodes are then connected via conductive copper wires. Finally, PDMS (polydimethylsiloxane) is used for external encapsulation. The electronic skin monitors pulse and heart rate changes that can be observed using smart devices. The composite nanofibers that form the core of the electronic skin show that the fibers are evenly distributed and have a uniform diameter. This allows the sensor to withstand high temperatures up to 341.0 °C. Its maximum open circuit voltage and short circuit current can reach 184.6 V and 10.8 µA, respectively. Experimental results show that it monitors the number of pulse beats consistent with normal human heart rate intervals.

4.1.2. Monitoring Body Movement

The movement changes of human joints are also one of the important indicators to reflect the physical condition. Under normal circumstances, the changes of human joints are regular and do not undergo long-term mutations. However, when the changes in the joints are so abrupt that they do not stick to the same pattern, it is important to consider the health of the body to avoid getting worse. Such real-time surveillance is crucial for the early detection and treatment of disease [61]. In recent years, the piezoelectric biosensor has developed rapidly and can meet the needs of capturing abnormal human motion signals. It can also monitor movements such as pronunciation, chewing and swallowing.
Compared with traditional sensors, today’s sensors are more convenient and provide a more timely feedback. As time progresses, the requirements for sensors are get higher. Not only should the sensitivity and stability be high, but also the cost should be as low as possible [62]. Chen et al. [63] invented a breathable sensor to monitor human movement. Figure 7 shows the fabrication process of the sensor and its real-time response to body movement. This sensor is fabricated by shearing the prepared IL/TPU (ionic liquid/thermoplastic polyurethane) nanofiber ionogel mat in different directions and then adding electrodes at both ends. It can be seen from the figure that most of the nanofibers are aligned. This enables the sensor to have a wide response range (>200%), fast response and recovery (119 ms) and low detection limits (0.1%). It can also be used as a stretchable temperature sensor. It has high sensitivity (2.75% °C–1), high precision (0.1 °C) and fast response time (2.46 s).
The sensors described above are based on electrospinning. It can be seen from the data that the sensor has excellent performance and it is versatile. Table 2 exemplifies the performance comparison of electrospinning piezoelectric biosensors with other piezoelectric biosensors.

4.2. Electrochemical Biosensor

Electrochemical biosensors are composed of various biomolecules (enzymes, DNA, microorganisms, antibodies) and electrochemical converters (amperometric, potentiometric, capacitive and conductometric). Its main principle is to convert chemical signals into electrical signals through chemical reactions between the biological materials on the sensitive components and the biological information in the measured object. Among them, there are many sensors using enzymes as biological materials, but the disadvantage is that the activity of enzymes is difficult to guarantee. There are many sensors based on other biological materials, such as DNA, cells, nucleic acids, and microorganisms. However, due to the peculiarity of these materials, they are not widely used in the field of electrospinning. The more commonly used enzymatic biosensors and non-enzymatic biosensors are introduced here.

4.2.1. Enzyme Biosensors

In recent years, the rapid development of non-invasive biosensors brings great convenience to sensor detection [74]. Human sweat, saliva and tears contain a lot of biological information. This enables the direct detection of these liquids by the enzymatic sensor. The biological information contained in these fluids can directly reflect the health of the body [75]. By detecting these liquids, you can know your physical condition more conveniently and quickly. Compared with traditional blood sampling, this method is non-invasive and cheaper. However, this method also has some disadvantages, such as the direct contact between sweat and air may lead to inaccurate measurement results.
In recent years, the main reason for the slow development of enzymatic sensors is that the inference from biological information carried in these liquids is not comprehensive enough [76]. In addition, the preservation and activity screening of enzymes are also difficult. Kim et al. [77] created a nanofiber hydrogel patch that can monitor glucose concentrations. Figure 8 shows the structure of the nanofiber hydrogel patch. The PVA NFs containing GOx/β-CD inclusion complexes with a crosslinking agent (BTCA) and AuNPs were electrospun from the aqueous solution mixture. The hydrogel was then steam treated with enzymes at 2 °C overnight. It can be seen from the figure that the fiber surface is smooth without defects. Fibers adhere but do not change shape or morphology. This gives the sensor a wide linear range (0.1 mM–0.5 mM), high sensitivity (47.2 µAmM−1) and low detection limit (0.01 mM).

4.2.2. Non-Enzymatic Biosensors

The disadvantage of enzyme sensors is that enzymes are affected by various environmental factors, such as temperature, humidity, oxygen concentration and pH value. This limits the application of enzymatic sensors in continuous detection [78]. The advent of non-enzymatic biosensors avoids this disadvantage. However, compared with enzymatic sensors, the specificity of non-enzymatic sensors is poor and the cost of some sensors is relatively high. Xu et al. [53] designed a highly sensitive non-enzymatic glucose sensor based on semiconductor nanocomposites by a simple electrospinning technique. Figure 9 shows the microstructure and performance characterization of this sensor. It designs a highly sensitive non-enzymatic glucose sensor based on semiconductor nanocomposites by a simple electrospinning technique. The fabrication characteristic of this sensor is that the nanofiber membrane is calcined in a Muffle furnace for 1 h at 280 °C and then for 2 h continuously at 450 °C until the Muffle furnace is cooled to room temperature. The diameter and length of the nanofibers decreased obviously during the whole calcination process, and this special treatment of the fiber membrane makes the sensor have high sensitivity (4022 μA mM−1 cm−2) and a low detection limit (0.08 μM).
It can be seen from the above that both the enzymatic and non-enzymatic sensors have good resolution for glucose. This is because the electrospun nanofibers have a higher specific surface area and can adsorb more biological elements to fully react with the analyte. Table 3 exemplifies the performance comparison of electrospinning piezoelectric biosensors with other piezoelectric biosensors.

4.3. Thermosensitive Biosensors

Body temperature is one of the important signs for detecting human health [92]. The traditional way of detecting body temperature is a mercury thermometer. However, this method takes a long time and is quite difficult to operate. Later, the body temperature gun was invented which is more convenient than the traditional one.
However, the measurement results may be inaccurate compared with mercury thermometers. In recent years, temperature sensors have developed rapidly. Sensors that can feedback body temperature information in time and measure it accurately have emerged.
As a wearable sensor, it must have a certain degree of biocompatibility and the material should be non-toxic [93]. The current body temperature sensors are patch type, electronic tattoo type and electronic bracelet type. These sensors are thermosensitive biosensors. Thermosensitive biosensors mainly rely on thermistors to sense temperature changes and thus lead to resistance changes. Jiang et al. [94] invented a multifunctional sensor that detects strain and temperature. Figure 10 is a manufacturing schematic and characterization of this multifunctional sensor. The sensor is made of TPU (thermoplastic polyurethane) nanofibers decorated with IL (ionic liquid) by ultrasonic anchoring technology. As can be seen from the element mapping diagram, the characteristic N, F and S elements of IL are uniformly distributed on the fiber surface. This gives the multifunctional sensor many good performances. As a strain sensor, it has a fast response time of 67 ms, ultra-low detection limit (0.1%) and ultra-wide detection range (0.1–400%). As a temperature sensor, its accuracy can reach 0.5 °C and the induction range from −40 °C to 80 °C. The sensor also provides excellent repeatability (response curve under 1500 cycles) and durability (the same signal can be obtained after 50 days).
Thermosensitive biosensors are becoming more sensitive to temperature, which results in higher requirements for sensors. Electrospun nanofibers have attracted much attention due to their excellent properties. Table 4 exemplifies the performance comparison of electrospinning thermosensitive biosensors with other thermosensitive biosensors.

4.4. Optical Biosensors

Humans are exposed to excessive including ultraviolet rays, which are more harmful to the human body. Long-term exposure to ultraviolet light may cause abnormalities such as skin cancer and skin aging [103]. This brings a lot of trouble to our lives. There are many ways to prevent ultraviolet radiation from having direct contact with the skin. Among them are the application of sunscreen and holding an umbrella. Wearable sensors that can detect the intensity of ultraviolet rays are relatively few. With the advancement of technology, wearable ultraviolet sensors have more and more functions. Not only can they detect the intensity of ultraviolet light, but it can also detect nearby environmental conditions. Most of these sensors use materials that are sensitive to ultraviolet light. When the UV intensity exceeds the normal level, it will cause the resistance of the sensor to change and remind the wearer to pay attention to sun protection.
Today’s wearable UV sensors are sticker-shaped, which can change color according to the intensity of UV rays [104]. They also compare the colors to get the UV intensity. Veeralingam et al. [105] invented a low-cost, tactile, high-performance and multi-functional sensing platform. Figure 11 shows the fabrication process and characterization of this sensor. The electrospun NiO nanofiber membranes were annealed in Muffle furnace for 6 h at 400 °C to decompose the polymer solution completely. Then the nanofiber membrane was uniformly dispersed in DMF (dimethylformamide) solution. A cut MS (Melamine sponge) was immersed in the solution for 1 h and then 4 h. After the fourth hour, MS was removed and dried at 70 °C for 1 h. It can be seen from the figure that, NiO fibers are interspersed evenly in the MS void. This gives the sensor numerous excellent performances. The sensor still has relatively stable current response under 500 cycles. Used for UV filter, UV protection coefficient can reach about 87.7. As a pressure sensor, the detection range is 50–700 N and the sensitivity can reach 3.75 kPa−1. As a strain sensor, the detection range is 7–74% and GF (gauge factor) can reach 34. Therefore, this sensor is feature-rich and has excellent performance.
Biosensors based on electrospinning to monitor light intensity are still relatively few. Electrospinning improves the performance of the sensor for light intensity detection to a certain extent. Table 5 exemplifies the performance comparison of electrospinning optical biosensors with other optical biosensors.
It can be seen from the above comparison that electrospinning technology has great advantages over other technologies. Not only does it have a better sensitivity and stability, but also its functions are broad. This is attributed to the high specific surface area of electrospun nanofibers. This also enables electrospinning technology to be widely used in the field of biosensors.

5. Conclusions

In recent years, electrospinning technology has developed rapidly and its application in the field of biosensors has become extensive [113]. Electrospun nanofibers have many excellent properties such as high porosity, high specific surface area, easy modification and low cost. These excellent characteristics also promote the wide application of electrospun nanofibers in the field of biosensors. Biosensors are now popular, especially in the medical field. The biosensor mainly acts on the human body to detect whether the physiological information of the human body is normal. There are many types of biosensors, which can detect various aspects of the human body’s physiological information and provide timely feedback to prevent the occurrence of diseases. It is foreseeable that the future development of electrospinning-based biosensors will have the following characteristics. (1) Diversified functions: Future biosensor functions will be more diverse and will integrate multiple functions. It can also detect physical diseases that people usually do not notice. (2) Convenience: With the advancement of nanotechnology, biosensors will become more convenient and more comfortable to wear. (3) Intelligence and integration: Future biosensors will be more closely connected to smart devices, and can form automatic collection of samples, analysis of samples and timely provide accurate results of the automated system. At the same time, chip technology will increasingly enter the field of sensors to realize the integration of detection system.
Although the development of electrospinning technology in the field of biosensors is very extensive, biosensors themselves have certain limitations that prevent them from being widely used. Because biological elements are the most important components in biosensors, biological materials on the surface of biological components are easy to inactivate and have poor reproducibility, making it difficult to guarantee their service life and storage. The biological element is closely related to the performance of the sensor. The high specific surface area of the electrospun nanofibers enables the attachment of a large number of biomaterials and contributes to the enhanced sensor performance. At the same time, electrospinning also has disadvantages, such as relatively unstable product consistency and many control factors. I believe that with the continuous advancement of electrospinning technology in future, more breakthroughs will be made in the field of biosensors.

Author Contributions

Conceptualization, Z.C.; Investigation, M.G. and Y.Z.; Writing—original draft preparation, G.J. and H.L.; Writing—review and editing, Z.C. and D.E.A. All authors have read and agreed to the published version of the manuscript.

Funding

This work was funded by the Six Talent Peaks Fund of Jiangsu Province (No. XCL-025) and the Key Research and Development Program of Anhui Province (No. 2022a05020064).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Lakshmanan, A.; Jin, Z.; Nety, S.P.; Sawyer, D.P.; Gosselin, A.L.; Malounda, D.; Swift, M.B.; Maresca, D.; Shapiro, M.G. Publisher Correction: Acoustic biosensors for ultrasound imaging of enzyme activity. Nat. Chem. Biol. 2020, 16, 1035. [Google Scholar] [CrossRef] [PubMed]
  2. Zhang, P.; Zhao, X.; Zhang, X.; Lai, Y.; Wang, X.; Li, J.; Wei, G.; Su, Z. Electrospun Doping of Carbon Nanotubes and Platinum Nanoparticles into the β-Phase Polyvinylidene Difluoride Nanofibrous Membrane for Biosensor and Catalysis Applications. ACS Appl. Mater. Interfaces 2014, 6, 7563–7571. [Google Scholar] [CrossRef] [PubMed]
  3. Yang, T.; Zhan, L.; Huang, C.Z. Recent insights into functionalized electrospun nanofibrous films for chemo-/bio-sensors. TrAC Trends Anal. Chem. 2020, 124, 115813. [Google Scholar] [CrossRef]
  4. Arida, I.A.; Ali, I.H.; Nasr, M.; El-Sherbinyet, I.M. Electrospun polymer-based nanofiber scaffolds for skin regeneration. J. Drug Deliv. Sci. Technol. 2021, 64, 102623. [Google Scholar] [CrossRef]
  5. Senthamizhan, A.; Balusamy, B.; Uyar, T. Recent progress on designing electrospun nanofibers for colorimetric biosensing applications. Curr. Opin. Biomed. Eng. 2020, 13, 1–8. [Google Scholar] [CrossRef]
  6. Liu, X.; Cheng, H.; Zhao, Y.; Wang, Y.; Li, F. Portable electrochemical biosensor based on laser-induced graphene and MnO2 switch-bridged DNA signal amplification for sensitive detection of pesticide. Biosens. Bioelectron. 2022, 199, 113906. [Google Scholar] [CrossRef] [PubMed]
  7. Wang, L.; Sipe, D.M.; Xu, Y.; Lin, Q. A MEMS Thermal Biosensor for Metabolic Monitoring Applications. J. Microelectromech. Syst. 2008, 17, 318–327. [Google Scholar] [CrossRef]
  8. Oh, J.; Yoo, G.; Chang, Y.W.; Kim, H.J.; Jose, J.; Kim, E.; Pyun, J.; Yoo, K.H. A carbon nanotube metal semiconductor field effect transistor-based biosensor for detection of amyloid-beta in human serum. Biosens. Bioelectron. 2013, 50, 345–350. [Google Scholar] [CrossRef] [PubMed]
  9. Jain, S.; Paliwal, A.; Gupta, V.; Tomar, M. Smartphone integrated handheld Long Range Surface Plasmon Resonance based fiber-optic biosensor with tunable SiO2 sensing matrix. Biosens. Bioelectron. 2022, 201, 113919. [Google Scholar] [CrossRef]
  10. Jandas, P.J.; Luo, J.T.; Prabakaran, K.; Chen, F.; Fu, Y.Q. Highly stable, love-mode surface acoustic wave biosensor using Au nanoparticle-MoS2-rGO nano-cluster doped polyimide nanocomposite for the selective detection of carcinoembryonic antigen. Mater. Chem. Phys. 2020, 246, 122800. [Google Scholar] [CrossRef]
  11. Li, C.; Li, Z.; Suo, S.; Li, X.; Cheng, Q.; Meng, S. Sensitivity enhancement by employing BiFeO3 and graphene hybrid structure in surface plasmon resonance biosensors. Opt. Mater. 2021, 121, 111618. [Google Scholar] [CrossRef]
  12. Hong, C.-C.; Lin, C.C.; Hong, C.L.; Lin, Z.X.; Chung, M.H.; Hsieh, P.W. Handheld analyzer with on-chip molecularly-imprinted biosensors for electrical detection of propofol in plasma samples. Biosens. Bioelectron. 2016, 86, 623–629. [Google Scholar] [CrossRef] [PubMed]
  13. Moore, E.; Rawley, O.; Wood, T.; Galvin, P. Monitoring of cell growth in vitro using biochips packaged with indium tin oxide sensors. Sens. Actuators B Chem. 2009, 139, 187–193. [Google Scholar] [CrossRef]
  14. Carrascosa, L.G.; Huertas, C.S.; Lechuga, L.M. Prospects of optical biosensors for emerging label-free RNA analysis. TrAC Trends Anal. Chem. 2016, 80, 177–189. [Google Scholar] [CrossRef] [Green Version]
  15. Jabbari Behrouz, S.; Rahmani, O.; Hosseini, S.A. On nonlinear forced vibration of nano cantilever-based biosensor via couple stress theory. Mech. Syst. Signal Process. 2019, 128, 19–36. [Google Scholar] [CrossRef]
  16. Farmani, H.; Farmani, A.; Nguyen, T.A. 12-Graphene-based field effect transistor (GFET) as nanobiosensors. In Silicon-Based Hybrid Nanoparticles; Thomas, S., Ahmadi, M., Joshi, N., Nguyen, T.A., Yasin, G., Eds.; Elsevier: Amsterdam, The Netherlands, 2022; pp. 269–275. [Google Scholar]
  17. Nuzaihan, M.N.M.; Hashim, U.; Md Arshad, M.K.; Kasjoo, S.R.; Rahman, S.F.A.; Ruslinda, A.R.; Fathil, M.F.M.; Adzhri, R.; Shahimin, M.M. Electrical detection of dengue virus (DENV) DNA oligomer using silicon nanowire biosensor with novel molecular gate control. Biosens. Bioelectron. 2016, 83, 106–114. [Google Scholar] [CrossRef]
  18. Song, Y.; Min, J.; Yu, Y.; Wang, H.; Gao, W. Wireless battery-free wearable sweat sensor powered by human motion. Sci. Adv. 2020, 6, eaay9842. [Google Scholar] [CrossRef] [PubMed]
  19. Peng, X.; Dong, K.; Ye, C.; Jiang, Y.; Wang, Z.L. A breathable, biodegradable, antibacterial, and self-powered electronic skin based on all-nanofiber triboelectric nanogenerators. Sci. Adv. 2020, 6, eaba9624. [Google Scholar] [CrossRef]
  20. Cordeiro, C.A.; Vries, M.D.; Ngabi, W.; Oomen, P.E.; Gremers, T.I.; Westerink, B.H.C. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device. Biosens. Bioelectron. 2015, 67, 677–686. [Google Scholar] [CrossRef]
  21. Smoak, M.M.; Hogan, K.J.; Grande-Allen, K.J.; Mikos, A.G. Bioinspired electrospun dECM scaffolds guide cell growth and control the formation of myotubes. Sci. Adv. 2021, 7, eabg4123. [Google Scholar] [CrossRef]
  22. Guo, J.; Fu, S.; Deng, Y.; Xu, X.; Laima, S.; Liu, D.; Zhang, P.; Zhou, J.; Zhao, H.; Yu, H.; et al. Hypocrystalline ceramic aerogels for thermal insulation at extreme conditions. Nature 2022, 606, 909–916. [Google Scholar] [CrossRef]
  23. Cheng, X.; Liu, Y.; Si, Y.; Yu, J.; Ding, B. Direct synthesis of highly stretchable ceramic nanofibrous aerogels via 3D reaction electrospinning. Nat. Commun. 2022, 13, 2637. [Google Scholar] [CrossRef]
  24. Singh, R.K.; Lye, S.W.; Miao, J. Holistic investigation of the electrospinning parameters for high percentage of β-phase in PVDF nanofibers. Polymer 2021, 214, 123366. [Google Scholar]
  25. Gade, H.; Nikam, S.; Chase, G.G.; Reneker, D.H. Effect of electrospinning conditions on β-phase and surface charge potential of PVDF fibers. Polymer 2021, 228, 123902. [Google Scholar] [CrossRef]
  26. Raksa, A.; Numpaisal, P.O.; Ruksakulpiwat, Y. The effect of humidity during electrospinning on morphology and mechanical properties of SF/PVA nanofibers. Mater. Today: Proc. 2021, 47, 3458–3461. [Google Scholar] [CrossRef]
  27. Raman, A.; Jayan, J.S.; Bds, D.; Appukuttan, S.; Joseph, K. Electrospun Nanofibers as Effective Superhydrophobic Surfaces: A Brief review. Surf. Interfaces 2021, 24, 101140. [Google Scholar] [CrossRef]
  28. Liu, Y.; Hao, M.; Chen, Z.; Liu, L.; Liu, Y.; Yang, W.; Ramakrishna, S. A review on recent advances in application of electrospun nanofiber materials as biosensors. Curr. Opin. Biomed. Eng. 2020, 13, 174–189. [Google Scholar] [CrossRef]
  29. Bayan, M.A.H.; Taromi, F.A.; Lanzi, M.; Pierini, F. Enhanced efficiency in hollow core electrospun nanofiber-based organic solar cells. Sci. Rep. 2021, 11, 21144. [Google Scholar]
  30. Yang, G.; Tang, X.; Zhao, G.; Li, Y.; Ma, C.; Zhuang, X.; Yan, J. Highly sensitive, direction-aware, and transparent strain sensor based on oriented electrospun nanofibers for wearable electronic applications. Chem. Eng. J. 2022, 435, 135004. [Google Scholar] [CrossRef]
  31. Farboudi, A.; Mahboobnia, K.; Chogan, F.; Karimi, M.; Askari, A.; Banihashem, S.; Davaran, S.; Irani, M. UiO-66 metal organic framework nanoparticles loaded carboxymethyl chitosan/poly ethylene oxide/polyurethane core-shell nanofibers for controlled release of doxorubicin and folic acid. Int. J. Biol. Macromol. 2020, 150, 178–188. [Google Scholar] [CrossRef]
  32. Zia, Q.; Tabassum, M.; Lu, Z.; Khawar, M.T.; Li, J. Porous poly(L–lactic acid)/chitosan nanofibres for copper ion adsorption. Carbohydr. Polym. 2020, 227, 115343. [Google Scholar] [CrossRef]
  33. Fu, Y.; Cheng, Y.; Chen, C.; Li, D.; Zhang, W. Study on preparation process and enhanced piezoelectric performance of pine-needle-like ZnO@PVDF composite nanofibers. Polym. Test. 2022, 108, 107513. [Google Scholar] [CrossRef]
  34. Zhang, K.; Zhao, W.; Liu, Q.; Yu, M. A new magnetic melt spinning device for patterned nanofiber. Sci. Rep. 2021, 11, 8895. [Google Scholar] [CrossRef] [PubMed]
  35. Wu, J.; Qin, X.; Miao, C.; He, Y.B.; Liang, G.; Zhou, D.; Liu, M.; Han, C.; Li, B.; Kang, F. A honeycomb-cobweb inspired hierarchical core–shell structure design for electrospun silicon/carbon fibers as lithium-ion battery anodes. Carbon 2016, 98, 582–591. [Google Scholar] [CrossRef]
  36. Zou, D.; Wang, W.; Liu, J.; Weng, J.; Duan, J.; Zhou, J.; Zhou, P. Insights into the storage mechanism of novel mesoporous hollow TiO2-x/C nanofibers as a high-performance anode material for sodium-ion batteries. Carbon 2022, 194, 248–256. [Google Scholar] [CrossRef]
  37. Kadadou, D.; Tizani, L.; SWadi, V.; Banat, F.; Alsafar, H.; FYousef, A.; Barcelo, D.; WHasan, S. Recent advances in the biosensors application for the detection of bacteria and viruses in wastewater. J. Environ. Chem. Eng. 2022, 10, 107070. [Google Scholar] [CrossRef]
  38. Jiménez-Rodríguez, M.G.; Silva-Lance, F.; Parra-Arroyo, L.; Medina-Salazar, D.A.; Martínez-Ruiz, M.; Melchor-Martínez, E.M.; Martínez-Prado, M.A.; Iqbal, H.; Parra-Saldívar, R.; Barceló, D. Biosensors for the detection of disease outbreaks through wastewater-based epidemiology. TrAC Trends Anal. Chem. 2022, 155, 116585. [Google Scholar] [CrossRef]
  39. Wang, F.R.; Wang, R. Modification of polyacrylonitrile-derived carbon nanofibers and bacteriophages on screen-printed electrodes: A portable electrochemical biosensor for rapid detection of Escherichia coli. Bioelectrochemistry 2022, 148, 108229. [Google Scholar] [CrossRef] [PubMed]
  40. Li, X.; Feng, Q.; Lu, K.; Huang, J.; Zhang, Y.; Hou, Y.; Qiao, H.; Li, D.; Wei, Q. Encapsulating enzyme into metal-organic framework during in-situ growth on cellulose acetate nanofibers as self-powered glucose biosensor. Biosens. Bioelectron. 2021, 171, 112690. [Google Scholar] [CrossRef]
  41. Maftoonazad, N.; Ramaswamy, H. Design and testing of an electrospun nanofiber mat as a pH biosensor and monitor the pH associated quality in fresh date fruit (Rutab). Polym. Test. 2019, 75, 76–84. [Google Scholar] [CrossRef]
  42. Wang, X.; Wang, Y.; Shan, Y.; Jiang, M.; Jin, X.; Gong, M.; Xu, J. A novel and sensitive electrogenerated chemiluminescence biosensor for detection of p16INK4a gene based on the functional paste-like nanofibers composites-modified screen-printed carbon electrode. J. Electroanal. Chem. 2018, 823, 368–377. [Google Scholar] [CrossRef]
  43. Pavinatto, A.; Mercante, L.A.; Facure Murilo, H.M.; Pena, R.B.; Sanfelice, R.C.; Luiz, H.C.; Correa, D.S. Ultrasensitive biosensor based on polyvinylpyrrolidone/chitosan/reduced graphene oxide electrospun nanofibers for 17α—Ethinylestradiol electrochemical detection. Appl. Surf. Sci. 2018, 458, 431–437. [Google Scholar] [CrossRef]
  44. Chadha, U.; Bhardwaj, P.; Rawat, P.; Agarwal, R.; Gupta, I.; Panjwani, M.; Singh, S.; Ahuja, C.; Selvaraj, S.K.; Banavoth, M. Recent progress and growth in biosensors technology: A critical review. J. Ind. Eng. Chem. 2022, 109, 21–51. [Google Scholar] [CrossRef]
  45. Zhu, P.; Peng, H.; Rwei, A.Y. Flexible, wearable biosensors for digital health. Med. Nov. Technol. Devices 2022, 14, 100118. [Google Scholar] [CrossRef]
  46. Wu, J.; Yin, F. Sensitive enzymatic glucose biosensor fabricated by electrospinning composite nanofibers and electrodepositing Prussian blue film. J. Electroanal. Chem. 2013, 694, 1–5. [Google Scholar] [CrossRef]
  47. Wei, X.; Zhu, M.; Li, J.; Liu, L.; Ding, B. Wearable biosensor for sensitive detection of uric acid in artificial sweat enabled by a fiber structured sensing interface. Nano Energy 2021, 85, 106031. [Google Scholar] [CrossRef]
  48. Yue, Y.; Gong, X.; Jiao, W.; Li, Y.; Ding, B. In-situ electrospinning of thymol-loaded polyurethane fibrous membranes for waterproof, breathable, and antibacterial wound dressing application. J. Colloid Interface Sci. 2021, 592, 310–318. [Google Scholar] [CrossRef]
  49. Luraghi, A.; Peri, F.; Moroni, L. Electrospinning for drug delivery applications: A review. J. Control. Release 2021, 334, 463–484. [Google Scholar] [CrossRef]
  50. Maity, K.; Garain, S.; Henkel, K.; Schmeier, D.; Mandal, D. Self-Powered Human-Health Monitoring through Aligned PVDF Nanofibers Interfaced Skin-Interactive Piezoelectric Sensor. ACS Appl. Polym. Mater. 2020, 2, 862–878. [Google Scholar] [CrossRef]
  51. Tang, J.; Wu, Y.; Ma, S.; Yan, T.; Pan, Z. Flexible strain sensor based on CNT/TPU composite nanofiber yarn for smart sports bandage. Compos. Part B Eng. 2022, 232, 109605. [Google Scholar] [CrossRef]
  52. Puttananjegowda, K.; Takshi, A.; Thomas, S. Silicon carbide nanoparticles electrospun nanofibrous enzymatic glucose sensor. Biosens. Bioelectron. 2021, 186, 113285. [Google Scholar] [CrossRef] [PubMed]
  53. Xu, Y.; Ding, Y.; Zhang, L.; Zhang, X. Highly sensitive enzyme-free glucose sensor based on CuO–NiO nanocomposites by electrospinning. Compos. Commun. 2021, 25, 100687. [Google Scholar] [CrossRef]
  54. Veeralingam, S.; Badhulika, S. Bi2S3/PVDF/Ppy-Based Freestanding, Wearable, Transient Nanomembrane for Ultrasensitive Pressure, Strain, and Temperature Sensing. ACS Appl. Bio Mater. 2021, 4, 14–23. [Google Scholar] [CrossRef] [PubMed]
  55. Jiang, Y.; Dong, K.; An, J.; Liang, F.; Yi, J.; Peng, X.; Ning, C.; Ye, C.; Wang, Z. UV-Protective, Self-Cleaning, and Antibacterial Nanofiber-Based Triboelectric Nanogenerators for Self-Powered Human Motion Monitoring. ACS Appl. Mater. Interfaces 2021, 13, 11205–11214. [Google Scholar] [CrossRef]
  56. Xiao, N.; Yu, W.; Han, X. Wearable heart rate monitoring intelligent sports bracelet based on Internet of things. Measurement 2020, 164, 108102. [Google Scholar] [CrossRef]
  57. Kaisti, M.; Panula, T.; Leppanen, J.; Punkkinen, R.; Tadi, M.J.; Vasankari, T.; Jaakkola, S.; Kivinieimi, T.; Airaksinen, J.; Kostiainen, P.; et al. Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation. Npj Digit. Med. 2019, 2, 1–10. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  58. Shahrestani, S.; Chou, T.C.; Shang, K.M.; Zada, G.; Borok, Z.; PRao, A.; Tai, Y.C. A wearable eddy current based pulmonary function sensor for continuous non-contact point-of-care monitoring during the COVID-19 pandemic. Sci. Rep. 2021, 11, 20144. [Google Scholar] [CrossRef]
  59. Lin, J.; Fu, R.; Zhong, X.; Yu, P.; Tan, G.; Li, W. Wearable sensors and devices for real-time cardiovascular disease monitoring. Cell Rep. Phys. Sci. 2021, 2, 100541. [Google Scholar] [CrossRef]
  60. Li, X.; Chen, S.; Zhang, X.; Li, J.; Liu, H.; Han, N. Poly-l-Lactic Acid/Graphene Electrospun Composite Nanofibers for Wearable Sensors. Energy Technol. 2020, 8, 1901252. [Google Scholar] [CrossRef]
  61. Nasiri, S.; Khosravani, M.R. Progress and challenges in fabrication of wearable sensors for health monitoring. Sens. Actuators A Phys. 2020, 312, 112105. [Google Scholar] [CrossRef]
  62. Qi, K.; He, J.; Wang, H.; Zhou, Y.; Cui, S. A Highly Stretchable Nanofiber-Based Electronic Skin with Pressure-, Strain-, and Flexion-Sensitive Properties for Health and Motion Monitoring. ACS Appl. Mater. Interfaces 2017, 9, 42951–42960. [Google Scholar] [CrossRef] [PubMed]
  63. Chen, J.; Wang, F.; Zhu, G.; Wang, C.; Cui, X.; Xi, M.; Chang, X.; Zhu, Y. Breathable Strain/Temperature Sensor Based on Fibrous Networks of Ionogels Capable of Monitoring Human Motion, Respiration, and Proximity. ACS Appl. Mater. Interfaces 2021, 13, 51567–51577. [Google Scholar] [CrossRef] [PubMed]
  64. Zhou, Y.; He, J.; Wang, H.; Qi, K.; Nan, N.; You, X.; Shao, W.; Wang, L.; Ding, B.; Cui, S. Highly sensitive, self-powered and wearable electronic skin based on pressure-sensitive nanofiber woven fabric sensor. Sci. Rep. 2017, 7, 12949. [Google Scholar]
  65. Su, Y.; Li, W.; Yuan, L.; Chen, C.; Pan, H.; Xie, G.; Conta, G.; Ferrier, S.; Zhao, X.; Chen, G. Piezoelectric fiber composites with polydopamine interfacial layer for self-powered wearable biomonitoring. Nano Energy 2021, 89, 106321. [Google Scholar] [CrossRef]
  66. Yang, C.-R.; Lin, M.F.; Huang, C.K.; Huang, W.C.; Tseng, S.F.; Chiang, H.H. Highly sensitive and wearable capacitive pressure sensors based on PVDF/BaTiO3 composite fibers on PDMS microcylindrical structures. Measurement 2022, 202, 111817. [Google Scholar] [CrossRef]
  67. Qin, Z.; Lv, Y.; Fang, X.; Zhao, B.; Niu, F.; Min, L.; Pan, K. Ultralight polypyrrole crosslinked nanofiber aerogel for highly sensitive piezoresistive sensor. Chem. Eng. J. 2022, 427, 131650. [Google Scholar]
  68. Kang, S.; Kim, S.H.; Lee, H.B.; Mhin, S.; Ryu, J.H.; Kim, Y.W.; LJones, J.; Son, Y.; Lee, N.K.; Lee, K. High-power energy harvesting and imperceptible pulse sensing through peapod-inspired hierarchically designed piezoelectric nanofibers. Nano Energy 2022, 99, 107386. [Google Scholar] [CrossRef]
  69. Yhuwana, Y.G.Y.; Apsari, R.; Yasin, M. Fiber optic sensor for heart rate detection. Optik 2017, 134, 28–32. [Google Scholar] [CrossRef]
  70. Ni, Y.; Liu, L.; Huang, J.; Li, S.; Chen, Z.; Zhang, W.; Lai, Y. Rational designed microstructure pressure sensors with highly sensitive and wide detection range performance. J. Mater. Sci. Technol. 2022, 130, 184–192. [Google Scholar] [CrossRef]
  71. Yuan, Y.; Chen, H.; Xu, H.; Jin, Y.; Chen, G.; Zheng, W.; Wang, W.; Wang, Y.; Gao, L. Highly sensitive and wearable bionic piezoelectric sensor for human respiratory monitoring. Sens. Actuators A Phys. 2022, 345, 113818. [Google Scholar] [CrossRef]
  72. Zhu, G.; Ren, P.G.; Wang, J.; Duan, Q.; Yan, D.X. A Highly Sensitive and Broad-Range Pressure Sensor Based on Polyurethane Mesodome Arrays Embedded with Silver Nanowires. ACS Appl. Mater. Interfaces 2020, 12, 19988–19999. [Google Scholar] [CrossRef] [PubMed]
  73. Yin, Y.M.; Li, H.Y.; Xu, J.; Zhang, C.; Zhu, G. Facile Fabrication of Flexible Pressure Sensor with Programmable Lattice Structure. ACS Appl. Mater. Interfaces 2021, 13, 10388–10396. [Google Scholar] [CrossRef]
  74. Poletti, F.; Zanfrognini, B.; Favaretto, L.; Quintano, V.; Sun, J.; Treossi, E.; Melucci, M.; Palermo, V.; Zanardi, C. Continuous capillary-flow sensing of glucose and lactate in sweat with an electrochemical sensor based on functionalized graphene oxide. Sens. Actuators B Chem. 2021, 344, 130253. [Google Scholar] [CrossRef]
  75. Zhou, J.; Men, D.; Zhang, X.-E. Progress in wearable sweat sensors and their applications. Chin. J. Anal. Chem. 2022, 50, 87–96. [Google Scholar] [CrossRef]
  76. Nyein, H.; Bariya, M.; Kivimki, L.; Uusitalo, S.; Javey, A. Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat. Sci. Adv. 2019, 5, eaaw9906. [Google Scholar] [CrossRef] [Green Version]
  77. Kim, G.J.; Kim, K.O. Novel glucose-responsive of the transparent nanofiber hydrogel patches as a wearable biosensor via electrospinning. Sci. Rep. 2020, 10, 18858. [Google Scholar] [CrossRef] [PubMed]
  78. Taşaltın, C. Glucose sensing performance of PAN: β-rhombohedral borophene based non-enzymatic electrochemical biosensor. Inorg. Chem. Commun. 2021, 133, 108973. [Google Scholar] [CrossRef]
  79. Rani, S.D.; Ramachandran, R.; Sheet, S.; Aziz, M.A.; Kumar, G.G. NiMoO4 nanoparticles decorated carbon nanofiber membranes for the flexible and high performance glucose sensors. Sens. Actuators B Chem. 2020, 312, 127886. [Google Scholar] [CrossRef]
  80. Liu, L.; Wang, Z.; Yang, J.; Liu, G.; Li, J.; Guo, L.; Shen, S.; Guo, Q. NiCo2O4 nanoneedle-decorated electrospun carbon nanofiber nanohybrids for sensitive non-enzymatic glucose sensors. Sens. Actuators B Chem. 2018, 258, 920–928. [Google Scholar] [CrossRef]
  81. Kanokpaka, P.; Chang, L.Y.; Wang, B.C.; Huang, T.H.; Shih, M.J.; Hung, W.S.; Lai, J.Y.; Ho, K.C.; Yeh, M.H. Self-powered molecular imprinted polymers-based triboelectric sensor for noninvasive monitoring lactate levels in human sweat. Nano Energy 2022, 100, 107464. [Google Scholar] [CrossRef]
  82. Zheng, L.; Liu, Y.; Zhang, C. A sample-to-answer, wearable cloth-based electrochemical sensor (WCECS) for point-of-care detection of glucose in sweat. Sens. Actuators B Chem. 2021, 343, 130131. [Google Scholar] [CrossRef]
  83. Jin, X.; Li, G.; Xu, T.; Su, L.; Yan, D.; Zhang, X. Fully integrated flexible biosensor for wearable continuous glucose monitoring. Biosens. Bioelectron. 2022, 196, 113760. [Google Scholar] [CrossRef]
  84. Xu, Z.; Song, J.; Liu, B.; Lv, S.; Gao, F.; Luo, X.; Wang, P. A conducting polymer PEDOT:PSS hydrogel based wearable sensor for accurate uric acid detection in human sweat. Sens. Actuators B Chem. 2021, 348, 130674. [Google Scholar] [CrossRef]
  85. Yao, Y.; Chen, J.; Guo, Y.; Lv, T.; Chen, T. Integration of interstitial fluid extraction and glucose detection in one device for wearable non-invasive blood glucose sensors. Biosens. Bioelectron. 2021, 179, 113078. [Google Scholar] [CrossRef] [PubMed]
  86. Toi, P.T.; Trung, T.Q.; Dang, T.; Bae, C.W.; Lee, N.E. Highly Electrocatalytic, Durable, and Stretchable Nanohybrid Fiber for On-Body Sweat Glucose Detection. ACS Appl. Mater. Interfaces 2019, 11, 10707–10717. [Google Scholar] [CrossRef] [PubMed]
  87. Shu, Y.; Su, T.; Lu, Q.; Shang, Z.; Xu, Q.; Hu, X. Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose Detection. Anal. Chem. 2021, 93, 16222–16230. [Google Scholar] [CrossRef] [PubMed]
  88. Zhu, Z.; Wu, Y.; Yang, J.; Xue, Y. Core-sheath fibers composed of F-doped nickel hydroxide nanorods and graphene fibers for effective fiber-shaped nonenzymatic glucose sensors. J. Alloys Compd. 2021, 889, 161608. [Google Scholar] [CrossRef]
  89. Bae, C.W.; Toi, P.T.; Kim, B.Y.; Lee, W.I.; Lee, H.B.; Hanif, A.; Lee, E.H.; Lee, N.E. Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring. ACS Appl. Mater. Interfaces 2019, 11, 14567–14575. [Google Scholar] [CrossRef] [PubMed]
  90. Sedighi, A.; Montazer, M.; Mazinani, S. Synthesis of wearable and flexible NiP0.1-SnOx/PANI/CuO/cotton towards a non-enzymatic glucose sensor. Biosens. Bioelectron. 2019, 135, 192–199. [Google Scholar] [CrossRef]
  91. Zhao, Y.; Zhai, Q.; Dong, D.; An, T.; Gong, S. Highly Stretchable and Strain-Insensitive Fiber-Based Wearable Electrochemical Biosensor to Monitor Glucose in the Sweat. Anal. Chem. 2019, 91, 6569–6576. [Google Scholar] [CrossRef]
  92. Han, S.; Kim, J.; Won, S.M.; Ma, Y.; Kang, D.; Xie, Z.; Lee, K.; Chung, H.U.; Banks, A.; Min, S. Battery-free, wireless sensors for full-body pressure and temperature mapping. Sci. Transl. Med. 2018, 10, eaan4950. [Google Scholar] [CrossRef] [Green Version]
  93. Wang, S.N.; Lv, R.Q.; Zhao, Y.; Qian, J.K. A Mach-Zehnder interferometer-based High Sensitivity Temperature sensor for human body monitoring. Opt. Fiber Technol. 2018, 45, 93–97. [Google Scholar] [CrossRef]
  94. Jiang, N.; Li, H.; Hu, D.; Xu, Y.; Hu, Y.; Zhu, Y.; Han, X.; Zhao, G.; Chen, J.; Chang, X. Stretchable strain and temperature sensor based on fibrous polyurethane film saturated with ionic liquid. Compos. Commun. 2021, 27, 100845. [Google Scholar] [CrossRef]
  95. Chen, M.; He, Y.; Liang, H.; Zhou, H.; Wang, X.; Heng, X.; Zhang, Z.; Gan, J.; Yang, Z. Stretchable and Strain-Decoupled Fluorescent Optical Fiber Sensor for Body Temperature and Movement Monitoring. ACS Photonics 2022, 9, 1415–1424. [Google Scholar] [CrossRef]
  96. Yang, Z.; Huang, T.; Cao, P.; Cui, Y.; Nie, J.; Chen, T.; Yang, H.; Wang, F.; Sun, L. Carbonized Silk Nanofibers in Biodegradable, Flexible Temperature Sensors for Extracellular Environments. ACS Appl. Mater. Interfaces 2022, 14, 18110–18119. [Google Scholar] [CrossRef] [PubMed]
  97. Trung, T.Q.; Dang, T.; Ramasundaram, S.; Toi, P.T.; Lee, N.E. A Stretchable Strain-Insensitive Temperature Sensor Based on Free-Standing Elastomeric Composite Fibers for On-Body Monitoring of Skin Temperature. ACS Appl. Mater. Interfaces 2019, 11, 2317–2327. [Google Scholar] [CrossRef] [PubMed]
  98. Cui, Z.; Poblete, F.R.; Zhu, Y. Tailoring the Temperature Coefficient of Resistance of Silver Nanowire Nanocomposites and their Application as Stretchable Temperature Sensors. ACS Appl. Mater. Interfaces 2019, 11, 17836–17842. [Google Scholar] [CrossRef]
  99. Pradhan, S.; Yadavalli, V.K. Photolithographically Printed Flexible Silk/PEDOT:PSS Temperature Sensors. ACS Appl. Electron. Mater. 2021, 3, 21–29. [Google Scholar] [CrossRef]
  100. Pang, Q.; Hu, H.; Zhang, H.; Qiao, B.; Ma, L. Temperature-Responsive Ionic Conductive Hydrogel for Strain and Temperature Sensors. ACS Appl. Mater. Interfaces 2022, 14, 26536–26547. [Google Scholar] [CrossRef]
  101. Li, F.; Xue, H.; Lin, X.; Zhao, H.; Zhang, T. Wearable Temperature Sensor with High Resolution for Skin Temperature Monitoring. ACS Appl. Mater. Interfaces 2022, 14, 43844–43852. [Google Scholar] [CrossRef]
  102. Song, J.; Wei, Y.; Xu, M.; Gao, J.; Luo, L.; Wu, H.; Li, X.; Li, Y.; Wang, X. Highly Sensitive Flexible Temperature Sensor Made Using PEDOT:PSS/PANI. ACS Appl. Polym. Mater. 2022, 4, 766–772. [Google Scholar] [CrossRef]
  103. Pielak, R.; Wei, P.; Peyret, H.; Balooch, G.; Rogers, J. 14188 Wearable UV/HEV light sensor and smartphone application for personal monitoring and personalized recommendations. J. Am. Acad. Dermatol. 2020, 83, AB133. [Google Scholar] [CrossRef]
  104. Araki, H.; Kim, J.; Zhang, S.; Banks, A.; Crawford, K.E.; Sheng, X.; Gutruf, P.; Shi, Y.; Pielak, R.M.; Rogers, J.A. Materials and Device Designs for an Epidermal UV Colorimetric Dosimeter with Near Field Communication Capabilities. Adv. Funct. Mater. 2017, 27, 1604465. [Google Scholar] [CrossRef]
  105. Veeralingam, S.; Priya, S.; Badhulika, S. NiO nanofibers interspersed sponge based low cost, multifunctional platform for broadband UV protection, ultrasensitive strain and robust finger-tip skin inspired pressure sensor. Chem. Eng. J. 2020, 389, 124415. [Google Scholar] [CrossRef]
  106. Cui, X.; Chen, J.; Wu, W.; Liu, Y.; Li, H.; Xu, Z.; Zhu, Y. Flexible and breathable all-nanofiber iontronic pressure sensors with ultraviolet shielding and antibacterial performances for wearable electronics. Nano Energy 2022, 95, 107022. [Google Scholar] [CrossRef]
  107. Feng, Y.; Shen, T.; Li, X.; Wei, X. ZnO-nanorod–fiber UV sensor based on evanescent field principle. Optik 2020, 202, 163672. [Google Scholar] [CrossRef]
  108. Yu, Z.; Xu, J.; Gong, H. Bioinspired Self-Powered Piezoresistive Sensors for Simultaneous Monitoring of Human Health and Outdoor UV Light Intensity. ACS Appl. Mater. Interfaces 2022, 14, 5101–5111. [Google Scholar] [CrossRef] [PubMed]
  109. Xu, Q.; Lou, J.; Zhang, R.; Ma, B.; Qin, Y. Self-Cleaning and Self-Powered UV Sensors for Highly Reliable Outdoor UV Detection. ACS Appl. Electron. Mater. 2020, 2, 1628–1634. [Google Scholar] [CrossRef]
  110. Sahare, P.D.; Srivastava, S.K.; Surender, K.; Fouran, S. n-ZnO/p-Si heterojunction nanodiodes based sensor for monitoring UV radiation. Sens. Actuators A Phys. 2018, 279, 351–360. [Google Scholar] [CrossRef]
  111. Yin, J.; Lu, C.; Li, C.; Yu, Z.; Shen, C.; Yang, Y.; Jiang, X.; Zhang, Y. A UV-filtering, environmentally stable, healable and recyclable ionic hydrogel towards multifunctional flexible strain sensor. Compos. Part B Eng. 2022, 230, 109528. [Google Scholar] [CrossRef]
  112. Kim, S.J.; Moon, D.I.; Seol, M.L.; Kim, B.; Han, J.W.; Meyyappan, M. Wearable UV Sensor Based on Carbon Nanotube-Coated Cotton Thread. ACS Appl. Mater. Interfaces 2018, 10, 40198–40202. [Google Scholar] [CrossRef] [PubMed]
  113. Chen, Y.W.; Yu, Q.W.; Chen, C.; Zhang, W.W.; Yu, C.; Yang, C.H.; Jin, S.X.; Xin, B.J. Research of Polysulfone Amide Micronanofiber Forming Technology. In Proceedings of the Textile Bioengineering and Informatics Symposium Proceedings (TBIS 2017), Wuhan, China, 16–19 May 2017; pp. 1205–1212. [Google Scholar]
Figure 1. The main development history of biosensors: (a) electrochemical biosensors [6]; (b) microthermal biosensors [7]; (c) biofield effect transistors [8]; (d) fiber-optic biosensors [9]; (e) acoustic biosensors [10]; (f) surface plasmon resonance biosensors [11]; (g) molecularly imprinted biosensors [12]; (h) biological chips [13]; (i) optic biosensors [14]; (j) nano cantilever biosensors [15]; (k) nano-biosensors [16]; (l) molecular biosensors [17]; (m) portable biosensors [18]; (n) wearable biosensors [19]; (o) in vivo biosensors [20].
Figure 1. The main development history of biosensors: (a) electrochemical biosensors [6]; (b) microthermal biosensors [7]; (c) biofield effect transistors [8]; (d) fiber-optic biosensors [9]; (e) acoustic biosensors [10]; (f) surface plasmon resonance biosensors [11]; (g) molecularly imprinted biosensors [12]; (h) biological chips [13]; (i) optic biosensors [14]; (j) nano cantilever biosensors [15]; (k) nano-biosensors [16]; (l) molecular biosensors [17]; (m) portable biosensors [18]; (n) wearable biosensors [19]; (o) in vivo biosensors [20].
Biosensors 12 00876 g001
Figure 2. Schematic diagram of electrospinning work [22,23].
Figure 2. Schematic diagram of electrospinning work [22,23].
Biosensors 12 00876 g002
Figure 3. Morphological characteristics of different kinds of nanofibers: (a) randomly distributed nanofibers [29]; (b) aligned nanofibers [30]; (c) core-shell nanofibers [31]; (d) multipace nanofibers [32]; (e) pine-needle nanofibers [33]; (f) patterned nanofibers [34]; (g) cobweb nanofibers [35]; (h) hollow nanofibers [36].
Figure 3. Morphological characteristics of different kinds of nanofibers: (a) randomly distributed nanofibers [29]; (b) aligned nanofibers [30]; (c) core-shell nanofibers [31]; (d) multipace nanofibers [32]; (e) pine-needle nanofibers [33]; (f) patterned nanofibers [34]; (g) cobweb nanofibers [35]; (h) hollow nanofibers [36].
Biosensors 12 00876 g003
Figure 4. Fundamentals of biosensors.
Figure 4. Fundamentals of biosensors.
Biosensors 12 00876 g004
Figure 5. Specific applications of electrospinning-based biosensors: (a) monitor heart rate. Reprinted with permission from ref. [50].Copyright 2020, American Chemical Society; (b) monitor body movement [51]; (c) enzymatic biosensor for detecting glucose concentration [52]; (d) non-enzymatic biosensor to detect glucose concentration [53]; (e) detect body temperature. Reprinted with permission from ref. [54]. Copyright 2021, American Chemical Society; (f) detect UV intensity. Reprinted with permission from ref. [55]. Copyright 2021, American Chemical Society.
Figure 5. Specific applications of electrospinning-based biosensors: (a) monitor heart rate. Reprinted with permission from ref. [50].Copyright 2020, American Chemical Society; (b) monitor body movement [51]; (c) enzymatic biosensor for detecting glucose concentration [52]; (d) non-enzymatic biosensor to detect glucose concentration [53]; (e) detect body temperature. Reprinted with permission from ref. [54]. Copyright 2021, American Chemical Society; (f) detect UV intensity. Reprinted with permission from ref. [55]. Copyright 2021, American Chemical Society.
Biosensors 12 00876 g005
Figure 6. (a) Preparation and application of electronic skin, (b) SEM image of composite nanofibers, (c) human pulse monitoring and rabbit heart rate monitoring [60].
Figure 6. (a) Preparation and application of electronic skin, (b) SEM image of composite nanofibers, (c) human pulse monitoring and rabbit heart rate monitoring [60].
Biosensors 12 00876 g006
Figure 7. The fabrication process of the sensor and its real-time response to human motion: (a) the process of making the sensor; (b) SEM image of IL/TPU mat; (c) real-time response of elbow and wrist; (d) real-time response to finger bending. Reprinted with permission from ref. [63]. Copyright 2021, American Chemical Society.
Figure 7. The fabrication process of the sensor and its real-time response to human motion: (a) the process of making the sensor; (b) SEM image of IL/TPU mat; (c) real-time response of elbow and wrist; (d) real-time response to finger bending. Reprinted with permission from ref. [63]. Copyright 2021, American Chemical Society.
Biosensors 12 00876 g007
Figure 8. Schematic diagram of a sweat sensor: (a) flow chart of making hydrogel patch, (b) SEM image of nanofiber, (c) electrochemical response diagram of sensor [77].
Figure 8. Schematic diagram of a sweat sensor: (a) flow chart of making hydrogel patch, (b) SEM image of nanofiber, (c) electrochemical response diagram of sensor [77].
Biosensors 12 00876 g008
Figure 9. Microstructure of nanofibrous membranes and performance characterization of sensors. (a) SEM image of nanofiber membrane, (b) TEM image of nanofiber membrane, (c) influence of different factors on glucose oxidative current, (d) the current time curve of the sensor for detecting glucose [53].
Figure 9. Microstructure of nanofibrous membranes and performance characterization of sensors. (a) SEM image of nanofiber membrane, (b) TEM image of nanofiber membrane, (c) influence of different factors on glucose oxidative current, (d) the current time curve of the sensor for detecting glucose [53].
Biosensors 12 00876 g009
Figure 10. Construction and characterization of multifunctional sensor: (a) construction and characterization of multifunctional sensor, (b) fiber surface map and element map, (c) cyclic performance as a function of 1500 loading-unloading cycles for the sensor, (d) the heat flow response of the sensor to different gears of the blower, (e) sensor response to repeated finger bending [94].
Figure 10. Construction and characterization of multifunctional sensor: (a) construction and characterization of multifunctional sensor, (b) fiber surface map and element map, (c) cyclic performance as a function of 1500 loading-unloading cycles for the sensor, (d) the heat flow response of the sensor to different gears of the blower, (e) sensor response to repeated finger bending [94].
Biosensors 12 00876 g010
Figure 11. Schematic diagram and characterization of the sensor: (a) the production process of the sensor, (b) transmittance versus wavelength graph, (c) characterization of fiber morphology, (d) current response under different strains, (e) continuous press and relax cycles of pressure sensor. Reprinted with permission from ref. [105]. Copyright 2020, Elsevier.
Figure 11. Schematic diagram and characterization of the sensor: (a) the production process of the sensor, (b) transmittance versus wavelength graph, (c) characterization of fiber morphology, (d) current response under different strains, (e) continuous press and relax cycles of pressure sensor. Reprinted with permission from ref. [105]. Copyright 2020, Elsevier.
Biosensors 12 00876 g011
Table 1. Common biological elements and loading methods.
Table 1. Common biological elements and loading methods.
Biological ElementsLoading MethodsPurposeRefs.
scherichia coli bacteriophageelectrostatic interactionrapid detection of Escherichia coli[39]
GOxencapsulation of enzymes into metal frameworks for in situ growthdetect glucose[40]
red cabbage extract (RCE)doping in PVA solutioncheck pH[41]
DNA oligonucleotidessoak the fiber membrane in the DNA solution and stirdetect p16INK4a gene[42]
burkholderia cepacia lipase (BCL)crosslinking with nanofibersDetect 17α- ethinylestradiol (EE2)[43]
Table 2. Performance of electrospinning in detecting heart rate and pulse with other techniques.
Table 2. Performance of electrospinning in detecting heart rate and pulse with other techniques.
MethodsMain MaterialSensitivityLinear RangeStabilityRefs.
ElectrospinningPVDF18.376 kPa−10.002–10 kPa7500[64]
PVDF0.38 V/N— —6834[65]
PVDF5 kPa−10–5 kPa— —[66]
CA60.28 kPa−10–24 kPa13,000[67]
P(VDF-TrFE)437.5 mV/μm
41.7 mV/μm
0–2 μm
2–10 μm
2000[68]
Fiber OpticPOF0.002 mV/μm
0.0004 mV/μm
150–650 μm
1400–3450 μm
— —[69]
Sacrifice template and sandpaper-treatedPDMS39.077 kPa−10.0009–160 kPa1400[70]
Laser etchingPVDF0.24 V/N— —4000[71]
CoatingPU4.169 kPa−10.02–10.3 kPa2300[72]
TPU1.02 kPa−10.0007–160 kPa60,000[73]
Table 3. Performance comparison of electrospinning and other technologies in detecting body fluids.
Table 3. Performance comparison of electrospinning and other technologies in detecting body fluids.
MethodsMain
Material
SensitivityLinear RangeStabilityRefs.
ElectrospinningPAN301.77 μAmM−1 cm−20.0003–4.5 mM80 days[79]
PAN1947.2 μAmM−1 cm−20.005–19.175 mM— —[80]
CoatingPVDF5.18 μAmM−1 cm−2— —— —[81]
fabric105.93 μAmM−1 cm−20.05–1 mM— —[82]
PU12.69 μAmM−1 cm−21–30 mM16 days[83]
HydrogelPEDOT:PSS0.875 µAµM−1 cm−22.0–250 μmolL–125 days[84]
Chemical vapor depositionnickel textile14.45 µAµM−1 cm−2— —— —[85]
Wet spinningPU140 μAmM−1 cm−2— —10,000[86]
PU425.9 μAmM−1 cm−210 μM–0.66 mM— —[87]
Ni(OH)595.3 μAmM−1 cm−20.01–7.66 mM— —[88]
DepositionPDMS253.4 μAmM−1 cm−2— —1000[89]
In-situ synthesizedfabric1625 μAmM−1 cm−20.001–1 mM— —[90]
1325 μAmM−1 cm−21–10 mM
Dry SpinningSEBS11.7 μAmM−1 cm−20–500 μM— —[91]
Table 4. Performance of electrospinning for body temperature detection with other technologies.
Table 4. Performance of electrospinning for body temperature detection with other technologies.
MethodsMain
Material
SensitivityLinear RangeStabilityRefs.
ElectrospinningPVDF
TPU
57.76/°C
2.75%/°C
24–48 °C
— —
5000
1000
[54]
[63]
Fiber OpticPANI8.962 nm/°C33–43 °C— —[93]
PDMS1.3%/°C20–50 °C— —[95]
Electrochemical DepositionGuHCl1.75%/°C35–63 °C— —[96]
Wet-spinningPU0.8%/°C— —— —[97]
Spray-coatedAgNW0.47 Ω/°C25–60 °C1000[98]
PEDOT:PSS−0.99%/°C20–50 °C— —[99]
Free radical polymerization NIPAAm−1.39%/°C30–37 °C— —[100]
0.37%/°C37–43 °C
In situ synthesizedTPU0.95%/°C20–40 °C— —[101]
Drop coatingPEDOT:PSS−0.803%/°C35–40 °C— —[102]
Table 5. Performance comparison of electrospinning applied to detect UV and other technologies.
Table 5. Performance comparison of electrospinning applied to detect UV and other technologies.
MethodsMain
Material
SensitivityLinear RangeStabilityRefs.
ElectrospinningPAN0.0574%— —— —[55]
TPU7.2%— —— —[106]
Fiber-OpticZnO
ZnO
7.096 W/(mWcm2)
— —
1527–1534 nm
1.5–12.5 mWcm2
— —
— —
[107]
[108]
Spin-coatedBaTiO323.11%
46.85%
67.92%
0.07 mWcm2
0.3 mWcm2
1.1 mWcm2
— —[109]
Rf-sputteringZnO50 µW/cm2— —100[110]
HydrogelsPVA10.88%365 nm— —[111]
78.26%650 nm
Ink-coatingCellulose
thread
4.76 mW/cm2254 nm— —[112]
0.76% mW/cm2365 nm
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Ji, G.; Chen, Z.; Li, H.; Awuye, D.E.; Guan, M.; Zhu, Y. Electrospinning-Based Biosensors for Health Monitoring. Biosensors 2022, 12, 876. https://doi.org/10.3390/bios12100876

AMA Style

Ji G, Chen Z, Li H, Awuye DE, Guan M, Zhu Y. Electrospinning-Based Biosensors for Health Monitoring. Biosensors. 2022; 12(10):876. https://doi.org/10.3390/bios12100876

Chicago/Turabian Style

Ji, Guojing, Zhou Chen, Hui Li, Desire Emefa Awuye, Mengdi Guan, and Yingbao Zhu. 2022. "Electrospinning-Based Biosensors for Health Monitoring" Biosensors 12, no. 10: 876. https://doi.org/10.3390/bios12100876

APA Style

Ji, G., Chen, Z., Li, H., Awuye, D. E., Guan, M., & Zhu, Y. (2022). Electrospinning-Based Biosensors for Health Monitoring. Biosensors, 12(10), 876. https://doi.org/10.3390/bios12100876

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop