Next Article in Journal
Pre-Stimulus Power but Not Phase Predicts Prefrontal Cortical Excitability in TMS-EEG
Next Article in Special Issue
Multiplex Surface-Enhanced Raman Scattering: An Emerging Tool for Multicomponent Detection of Food Contaminants
Previous Article in Journal
In Vivo Plant Bio-Electrochemical Sensor Using Redox Cycling
Previous Article in Special Issue
Accurate and Rapid Genetic Tracing the Authenticity of Floral Originated Honey with the Molecular Lateral Flow Strip
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Assessing Meat Freshness via Nanotechnology Biosensors: Is the World Prepared for Lightning-Fast Pace Methods?

1
Faculty of Food Science and Nutrition, Universiti Malaysia Sabah, Kota Kinabalu 88400, Sabah, Malaysia
2
Faculty of Sustainable Agriculture, Universiti Malaysia Sabah, Locked Bag No. 3, Sandakan 90509, Sabah, Malaysia
*
Author to whom correspondence should be addressed.
Biosensors 2023, 13(2), 217; https://doi.org/10.3390/bios13020217
Submission received: 1 December 2022 / Revised: 11 January 2023 / Accepted: 12 January 2023 / Published: 2 February 2023
(This article belongs to the Special Issue Application of Biosensors in Food Safety Analysis)

Abstract

:
In the rapidly evolving field of food science, nanotechnology-based biosensors are one of the most intriguing techniques for tracking meat freshness. Purine derivatives, especially hypoxanthine and xanthine, are important signs of food going bad, especially in meat and meat products. This article compares the analytical performance parameters of traditional biosensor techniques and nanotechnology-based biosensor techniques that can be used to find purine derivatives in meat samples. In the introduction, we discussed the significance of purine metabolisms as analytes in the field of food science. Traditional methods of analysis and biosensors based on nanotechnology were also briefly explained. A comprehensive section of conventional and nanotechnology-based biosensing techniques is covered in detail, along with their analytical performance parameters (selectivity, sensitivity, linearity, and detection limit) in meat samples. Furthermore, the comparison of the methods above was thoroughly explained. In the last part, the pros and cons of the methods and the future of the nanotechnology-based biosensors that have been created are discussed.

1. Introduction

Over the years, the consumption of meat products has increased significantly across the globe [1]. Determination of meat quality is currently one of the most pressing concerns in the meat industry, along with maintaining the freshness and quality of the meat, as meat can be easily degraded during processing and storage [2]. It is challenging to evaluate the freshness of meat, as it involves changes in aging as well as meat spoilage-related microbiological, physicochemical, and biochemical characteristics [3]. Aging is a process that involves complicated changes in muscle metabolism in the post-slaughter process or storage phase, requiring the meat to achieve the optimal state for eating and determining meat tenderness [4]. ATP degradation is also one of the most important biochemical changes in the postmortem muscle of meat [5]. Adenosine triphosphate (ATP) is decomposed into adenosine-5′-diphosphate (ADP) and sequentially degrades to adenosine-5′-monophosphate (AMP), inosine-5′-monophosphate (IMP), inosine (HxR), hypoxanthine (Hx), xanthine (Xa), and uric acid (UA) [6,7]. The changes due to ATP degradation are considered an accurate way of evaluating the freshness of meat, as a high concentration of ATP catabolites correlates well with the loss of freshness in meat [8,9].
Numerous conventional techniques have been established for the detection of purine, including high-performance liquid chromatography (HPLC) [10,11], liquid chromatography-mass spectrometry (LC-MS) [12], UV visible spectrophotometry [13], and capillary electrophoresis (CE) [14]. Those techniques were used in the late twentieth century, and the majority of these techniques are still widely used today. For instance, HPLC is a highly sensitive and reproducible analytical technique [15]. It has the ability to quantify seven purine metabolites across the entire purine metabolic pathway and separate complex mixtures into their constituent parts [16]. Although the aforementioned techniques enable high selectivity and low detection limits, they can be extremely time-consuming, labor-intensive, resource-intensive, and require highly expensive equipment.
Given these drawbacks, there is a growing interest in using nanotechnology biosensors for the simple and real-time monitoring of the quality and safety of perishable food, with the goal of preventing food poisoning, food waste, and economic losses [17]. The emerging role of nanotechnology biosensors guarantees that everyone in the cold chain, from the consumer to the distributor, has easy access to data regarding the freshness of the food they are handling at any given time because of their simplicity, low cost, and satisfactory analytical performances. Recently, nanobiosensors have been implemented in the detection of purine derivatives, such as hypoxanthine, xanthine, and uric acid, to determine the freshness level of meat [8,18,19,20,21]. Nanobiosensors have not only been implemented in the meat industry, but have also been effectively applied in detecting endocrine-disrupting chemicals (EDCs) and heavy metals, such as Hg2+, in water [22,23]. These nanobiosensors showed excellent and satisfactory analytical performances in terms of their sensitivity, selectivity, linear range, and detection limit. Their validity for quantification of purine derivatives has been analyzed using conventional methods, and it shows that nanobiosensors are comparable to the purine derivatives detected by conventional methods [20,24,25].
Herein, this article compares conventional techniques and nanotechnology biosensors for the detection of purine derivatives in determining the freshness of meat. Additionally, this study focuses on two of the most commonly reported approaches: electrochemical and optical methods utilizing different types of nanomaterials in meat freshness detection which summarize at Figure 1. The most recent works are presented, detailing not only the analytical performance parameters but also the application of the sensing platform to the analysis of real samples. Finally, concluding remarks and future perspectives are discussed.

2. Meat Freshness Indicators

Meat freshness can be defined in various ways. From the consumer’s point of view, the freshness of meat can be defined as an acceptable organoleptic property of tenderness, color, juiciness, and flavor [26]. Meanwhile, in the scientific aspect, the freshness of the meat is related to the microbial, chemical, sensory, and technological attributes of the meat [27]. Meat freshness can be evaluated using a microbial count; however, this method often requires a longer time to analyze the findings, as a bacterial count usually takes time for the incubation period [28]. The freshness of meat deteriorates due to the degradation of meat commonly caused by microbial, chemical, and pharmaceutical residue contamination [29]. Postmortem reactions, such as glycolysis, proteolysis, and lipolysis, also affect meat quality, usually occurring right after an animal is slaughtered [30,31].
After an animal is slaughtered, the skeletal muscle experiences physical and biochemical changes, thus, disrupting the stable interior environment and causing a depletion of blood flow and oxygen supply [32]. Physical and biochemical changes will continue to degrade or deplete even under chilled storage and, thus, affect the acceptability of the meat [33]. However, despite low blood flow and oxygen supply, the skeletal muscle does not stop producing ATP; synthesis of ATP occurs through the catabolism of stored glycogen, leading to lactate production and a lower pH of the meat [32]. Eventually, the ATP in the muscle will decrease and lead to the dysfunction of the sarcoplasmic reticulum, activating the ATP enzyme and decomposing the ATP into its metabolites [34]. The catabolic pathway of ATP generates metabolites, such as adenosine diphosphate (ADP), adenosine monophosphate (AMP), inosine monophosphate (IMP), inosine (INO), and hypoxanthine (Hx) [35]. Hypoxanthine (Hx) will further oxidize and, thus, produce xanthine (Xa) and uric acid (UA) [5]. The changes due to ATP degradation are considered an accurate way of evaluating the freshness of meat, as a high concentration of ATP catabolites correlates well with the loss of freshness in meat [36].
The concentration of IMP rose rapidly while ATP, ADP, and AMP were rapidly broken down [37]. The degradation of ATP to IMP is associated with the umami taste, which provides a pleasant savory taste to meat [21,38]. However, the disappearance of IMP and the formation of INO and hypoxanthine have always been connected to the loss of freshness in meat. Hypoxanthine commonly indicates the freshness of meat and the storage time of meat [39]. The catabolism of ATP forming IMP is mainly caused by enzymatic reactions; however, the hydrolysis of IMP forming INO and hypoxanthine is mainly affected by spoilage bacteria [6,40]. ATP-related compounds degrade rapidly in the presence of enzymes including ATPase, myokinase, AMP deaminase, 5′-nucleotidase, nucleoside phosphorylase, and xanthine oxidase [40,41,42]. The role of each enzyme in the catabolism of ATP to its metabolites is shown in Figure 2.

3. Conventional Techniques Used for Quantification of Purine Derivatives

To date, several traditional methods for quantifying purine derivatives in biological and food samples have been used, including high performance liquid chromatography (HPLC) [43,44,45], capillary electrophoresis (CE) [46], ultra-high performance liquid chromatography with mass spectrometry (UHPLC-MS) [47,48], gas chromatography-mass spectrometry (GC-MS) [49], mass spectrometry [50], and spectrophotometric methods [51], all of which provide high precision and sensitivity, and are summarized in Table 1. Despite their high selectivity and low detection limits, the above methods require highly expensive equipment and are extremely time-consuming, labor-intensive, human-intensive, and economically demanding [15,52].

3.1. High-Performance Liquid Chromatography (HPLC)

In recent times, liquid chromatography has increasingly become a standard technique. Liquid chromatography is usually coupled with mass spectrometry to provide a simple and robust interface. In both liquid chromatography and mass spectrometry, compounds are separated and identified based on the retention, efficiency, and selectivity of the separation mechanism [60]. Reversed-phase liquid chromatography or ion chromatography is usually used to analyze nitrogen bases, including purine and pyrimidine [61]. HPLC is often used to measure purines in food. It can be used on a wide variety of foods, including those that come from plants, fungi, and animals. Nevertheless, samples need to be pretreated appropriately. Furthermore, the chromatographic column, concentration of the mobile phase, pH, flow rate, column temperature, and wavelength of detection may influence quantification [62]. Therefore, the optimal conditions for chromatography are crucial in order to correctly quantify the particular compounds.
According to a recent study, the maximum number of purines in marine fish and aquatic products was estimated using HPLC with Agilent Eclipse XDB-C18 chromatography columns (4.6 mm × 250.0 mm × 5.0 mm) (Stevens Creek Blvd., Santa Clara, CA, USA) [63]. Adenine, guanine, hypoxanthine, and xanthine had LODs of 0.0774, 0.0178, 0.0118, and 0.0555 mg/L, respectively. Marine fish viscera contained significantly more purine than muscle, but had higher levels of adenine, guanine, and hypoxanthine. In another study, Qu et al. [45] used HPLC to detect four different purines in fish and shellfish and separated the purines into adenine, guanine, hypoxanthine, and xanthine. Excellent linearity was observed for adenine, guanine, hypoxanthine, and xanthine in the range of 0.05–300 mg/L, with the recoveries ranging from 91.5 to 105.0, respectively. Snails and shrimp contained more purines than fish and bivalves, and fish livers and skins contained more purines than muscles. Purines differ depending on the type of seafood. An analysis published by Fukuuchi et al. [53] determined 18 types of purines in three types of soup stocks (chicken consommé, dried bonito soup) by HPLC. There was the highest proportion of inosine monophosphate (IMP) in all umami soup stocks, followed by hypoxanthine, inosine, and guanosine monophosphate (GMP). Among the three soup stocks, dried bonito soup had the highest IMP content.
Hyperuricemia can be caused by consuming purine-rich foods. Previously, Larashinda et al. [54] analyzed the purine content of food from chicken in West Sumatra. Raw chicken meat contains a higher amount of purine than chicken rendang, chicken curry, chicken grilled, chicken balado, chicken seasoned, and chicken pop. Meanwhile, Vlassa et al. [16] simultaneously quantified allantoin, uric acid, xanthine, and hypoxanthine in cow milk by the HPLC-DAD method. In this experiment, an ODS-2 hypersil column was used as the chromatographic column and a 0.05 M (NH4)2HPO4 buffer solution (pH = 7.76) as the mobile phase. As indicated by the regression coefficient higher than 0.999, the HPLC-DAD validated method exhibited linearity, and the limits of detection and quantification ranged from 0.09 to 0.74 µg mL–1 and 0.27 to 2.24 µg mL–1. In addition, Wu et al. [55] developed a sensitive and accurate method of measuring purines and uric acid in Chinese chicken broth for hyperuricemia dietary management using high-performance liquid chromatography with variable wavelength detectors (HPLC-VWD). Chromatographic separation was performed on an Agilent TC-C18 (2) column (4.6 mm × 250 mm, 5.0 µm), using 0.02 M KH2PO4 (pH 4.0) as a mobile phase. In a recent study, Xiao et al. [56] used acidolysis and HPLC to compare the purine content of shiitake mushrooms after roast-drying, freeze-drying, and sun-drying. After roast-drying (120 °C), adenine levels decreased significantly, suggesting that DNA was damaged by thermal shock. Freeze-dried shiitake mushrooms had significantly less purine than roasted or sun-dried mushrooms.

3.2. Capillary Electrophoresis (CE)

Capillary electrophoresis (CE) is a method of separating compounds with different charges in a short period of time, particularly when they are known compounds. When CE is used to separate compounds, the peaks of the compounds can be compared with the peaks of the standards. Assays using CE are highly sensitive and repeatable, and they require little reagent, which reduces the cost [64]. Furthermore, CE is an automated machine that is handled through automated processes, making it a very useful machine in routine analytical work [46]. Separation of rich biological matrices by CE is equally common during proteolysis evaluations of dairy products [65] or meat [66]. Despite the foregoing, only a few studies on the use of CE for quality assessment of fish and meat products are available.
An electrophoresis method based on capillary zones (CZE) was developed by Zhu et al. [57] for the analysis of adenine nucleotides from yeast extracts. Based on its validation analyses, the method is relatively reliable and accurate, with high precision and recovery. Accordingly, Klampfl et al. [58] separated purine and pyrimidine bases in beer samples using the CZE technique and direct UV detection. Analytes were adequately separated from peaks associated with the sample matrix using the strongly alkaline carrier electrolyte based on diethylamine. Mu et al. [59] found four purines in soybean milk, including adenine, guanine, hypoxanthine, and xanthine, using the CE method with UV detection. The strongly alkaline carrier electrolyte based on DEA employed throughout this work provided sufficient separation of the investigated analytes from peaks related to the sample matrix. Various kinds of soybean milk samples were successfully analyzed using optimized acid hydrolysis followed by the CE method. A comparison was also made between the results obtained by the proposed CE method and those obtained by HPLC. Comparatively, CE performed well, and the quantitative results were similar to HPLC, while CE had the advantages of being significantly quicker and more affordable than HPLC.

4. Nanotechnology Biosensor Used in Determining Purine Derivatives

Nanotechnology involves the study of extremely small structures, between 0.1 and 100 nm in size, which have a variety of applications for sensor technologies [67]. The application of nanotechnology to biosensors forms the basis for developing nanobiosensors that are able to improve the sensitivity and specificity of biomolecule detection and show great potential in the food industry for diagnostics and biomolecular recognition [68,69]. Nanotechnology is gaining attraction in the food industry, as nanotechnology-based sensors are being used to measure food metabolites [70,71]. Biosensors are devices that use biological materials to detect and measure substances in a sample. These materials, called biorecognition elements, can include enzymes, antibodies, nucleic acids, cell receptors, micro-organisms, tissues, organelles, and natural products. They can also be biomimics, such as imprinted polymers, biomimetic catalysts, synthetic receptors, or combinatorial ligands. Alternatively, they can be biologically derived materials, such as functional nucleic acids, recombinant micro-organisms, or engineered proteins. The biorecognition element is combined with a physicochemical transducer, which is a device that converts the biochemical reaction into a measurable signal. This transducer can be electrochemical, optical, magnetic, thermometric, piezoelectric, or micromechanical in nature [72,73,74]. The selection of substrate to be fabricated onto the biosensor is important for inventing an efficient biosensor, as the dispersion of the sensing materials indicates the performance of the sensor [75,76]. According to previous studies, the employment of different nanomaterials (nanoparticles, carbon nanotubes (CNTs), quantum dots, and magnetic nanoparticles) led to the introduction of many new signal transduction technologies, as can be seen clearly in Table 2 and Table 3.

4.1. Electrochemical Biosensor

Electrochemical biosensors are becoming popular alternatives due to their good selectivity, sensitivity, and simplicity of operation. Not the least, the use of electrochemical biosensors can allow direct analysis of the analytes within a short time and is easy to conduct without trained personnel. Nowadays, food quality analysis or quality control departments require a fast response and field devices that can help detect certain contaminants present in the food. Foods, such as meat, are categorized as perishable foods, and the freshness of meat might degrade over storage time. Freshness indicators in meat can be measured by determining the concentration of hypoxanthine (Hx), xanthine (Xa), and uric acid (UA) in the meat [77]. Several methods have been developed to analyze and monitor the presence of purine derivatives in meat samples.
An electrochemical biosensor can be classified into three categories based on the type of signal it measures: amperometric, voltammetric, or conductometric. Amperometry measures the current flowing through a solution [78], voltammetry measures the potential of an electrode as a function of time [79], and conductometry measures the electrical conductivity of a solution [80]. In short, amperometry, voltammetry, and conductometry are all techniques used to measure the electrical properties of solutions and are often used in chemical analysis and in the development of sensors [81]. Additionally, enzyme sensors are often paired with amperometric and potentiometric electrochemicals because enzyme-based biosensors are highly sensitive and specific, portable, cost-effective, and can be miniaturized and tested at the point-of-care, which makes them increasingly attractive for clinical study, food safety management, or disease monitoring research purposes [82]. Table 2 summarizes the recent trends of electrochemical biosensors in detecting meat freshness and their analytical performance in food applications.
In recent years, various amperometric biosensors have been developed for the detection of xanthine and hypoxanthine as indicators of fish freshness. Amperometry is often used to measure the concentration of a specific ion in a solution. In amperometry, a potential is applied to an electrode, and the current that flows through the solution is measured [81]. The current is proportional to the concentration of the ion being measured. Amperometry is a sensitive technique that is particularly useful for measuring low concentrations of ions and detecting rapid changes in ion concentrations [78]. Recently, Wang et al. [83] designed an amperometry biosensor that has successfully immobilized xanthine oxidase on copper-based metal-organic (Cu-MOF) film to monitor the freshness of chilled squid and large yellow croaker. The designed XOD-electrochemical biosensor showed good sensitivity to hypoxanthine and xanthine, with a linear range of 0.01–10 μM. It also showed a low LOD of 0.0023 and 0.0064 μM for hypoxanthine and xanthine, respectively. Joon et al. [84] proposed an amperometric xanthine biosensor for fish meat freshness detection. It was developed by attaching xanthine oxidase nanoparticles (XODNPs) to gold (Au) electrodes. This biosensor showed a limit of detection and linearity of 0.01 μM and 0.01 to 1.0 μM, respectively. The use of xanthine oxidase nanoparticles in the construction of an amperometric xanthine biosensor eased its fabrication because XODNPs were immobilized directly onto polycrystalline Au electrodes via covalent coupling. Furthermore, hypoxanthine in fish samples can also be assessed via the designed biosensor composed of xanthine oxidase and uricase, which were immobilized on the surface of platinum via electrochemical polymerization of polypyrrole-paratoluenesulfonate (PPy-pTS). The developed amperometric biosensor showed a good LOD of 5 × 10−6 M and a wide linear working range from 5 × 10−6 to 5 × 10−3 M [85].
In addition, Sharma et al. [86] constructed an amperometric biosensor in which xanthine oxidase (XO) was extracted from Bacillus pumilus RL-2d and covalently immobilized onto screen-printed multiwalled carbon nanotubes with gold nanoparticle-based electrodes (Nano-Au/c-MWCNT). It revealed a good sensitivity of 2388.88 µA/cm2/nM and a LOD of 1.14 nM. Similarly, Albelda et al. [3] also fabricated an enzyme-based sensor of xanthine oxidase along with graphene/titanium dioxide nanocomposite (TiO2-G) and immobilized it onto the glassy carbon electrode. The sensor was used to determine the presence of hypoxanthine in meat. The fabricated Nafion/XOD/TiOtrip-G/GCE sensor demonstrated a linear range of 20–512 μM with a LOD of 9.5 μM. Additionally, it was also revealed to have minimal interference from xanthine and showed a strong anti-interference towards uric acid, ascorbic acid, and glucose. These biosensors are therefore an effective and alternative way to assess the freshness of meat in an accurate manner. Tripathi et al. [19] also immobilized xanthine oxidase on the macroporous surface of a nickel oxide electrode prepared via a glancing-angle deposition. The developed biosensor showed a rapid response time of 7 s with a very high selectivity and sensitivity of 1.1 μA μM–1cm–2 towards xanthine. It also revealed good reproducibility with a superior LOD of 37 nM.
Complementarily, Sahyar et al. [87] immobilized xanthine oxidase onto a modified electrode of entrapped silver-doped zinc oxide nanoparticles (nano-Ag-ZnO) on a pencil graphite electrode electropolymerized by pyrrole. The biosensor showed excellent selectivity, with a superior sensitivity of 0.03 μA/mM and a LOD of 0.07 μM. Boluda et al. (2021) synthesized an amperometric biosensor via electrodeposition of ferrocenyl polycyclosiloxane polymers as a matrix for electrosynthesizing Pt nanoparticles. Xanthine oxidase was covalently immobilized onto the matrix and has achieved a good sensitivity towards xanthine with a linear range of 0.1–1.4 mM. Additionally, it also successfully applied the fish sample to detect xanthine as low as 48 nM. Those aforementioned biosensors have the same similarity, in that all the biosensors are immobilized with xanthine oxidase enzymes. The extensive usage of xanthine oxidase in assessing the freshness of meat is due to its biocompatibility, good mechanical performance, high activity, and stability, as well as its ability to produce a strong and reversible current in the presence of oxygen, which makes it suitable for use in biosensors [88]. Additionally, xanthine oxidase is an enzyme that catalyzes the oxidation of xanthine to uric acid and is important in the metabolism of purines in the body [89]. Therefore, xanthine oxidase is useful in the measurement of xanthine and uric acid concentrations.
However, there are also amperometric biosensors that do not immobilize enzymes on the matrix of the biosensor. Recently, Ahmad et al. [90] used sea-urchin-like cobalt-MOF (Co(TMA)MOF@CNF) on electrospun carbon nanofiber mat as a self-supporting electrode for sensing of xanthine (Xa) and uric acid (UA) in fish meat. Amperometric current response versus analyte concentration calibration plots were found to be linear over a board concentration range of 25–700 µM, with low detection limits of 96.2 nM and 103.5 nM for the Xa and UA, respectively. The sensor sensitivity for Xa is found to be 14.28 μA μM−1cm−2 and 5.78 μA μM−1cm−2 for UA. Co(TMA)MOF@CNF sensor provided acceptable results in detecting UA levels in the blood serum of gout patients, indicating its applicability for medical diagnosis. Meanwhile, Malhotra et al. [91] synthesized an amperometric biosensor for the detection of xanthine in chicken meat. The biosensors were composed of a 3-D self-supported electrocatalyst of cerium oxide nanocrystals doped with cobalt heteroatoms (CeO2-Co) and were homogeneously covered with 1-D tin oxide (SnO2) nanorods supported by a carbon cloth substrate. The proposed biosensor showed a wide linearity of 25–55 µM with a satisfactory LOD of 58 nM. Both electrospun carbon nanofiber mat and 1-D tin oxide (SnO2) nanorods have also been widely used in the development of amperometric biosensors due to their high surface area, which allows for the efficient immobilization of enzymes and other biomolecules, good electrical conductivity, which allows for the efficient transfer of electrons during the electrochemical reaction, and excellent stability, which makes them suitable for long-term use in biosensors. Despite their advantages, both CNF mat electrodes and SnO2 nanorods have some limitations in the development of amperometric biosensors. CNF mat electrodes are prone to aggregation, which can affect their performance in biosensors. SnO2 nanorods also have the tendency to aggregate and are sensitive to environmental conditions, which can also affect their performance in biosensors [92]. These revealed that biosensors that were constructed today have the potential to act as efficient sensors with great sensitivity and high accuracy in monitoring the food quality.
Another technique that is commonly used in electrochemical biosensors is voltammetry. Voltammetry is a versatile technique that can be used to measure the rate of a chemical reaction at an electrode and to determine the concentration of species in a solution. It is often used to study the electrochemistry of reactions and to develop sensors [93]. Recently, Khan et al. [94] detected xanthine in fish and meat samples using functionalized gold nanoparticles (GCE/PEDOT:PSS-AuNPs) assembled onto a host matrix of modified glassy carbon electrodes with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) nanocomposite. The proposed biosensor showed a linear range of 5.0 × 10−8 to 1.0 × 10−5 M and a good LOD of 3.0 × 10−8 M. Ghanbari and Nejabati [95] schemed a voltammetric sensor based on a reduced graphene oxide/chitosan/chromium oxide nanocomposite-modified glassy carbon electrode (GCE/rGO/CS/Cr2O3) to monitor the levels of dopamine (DA), uric acid (UA), xanthine (Xa), and hypoxanthine (Hx) in fish. The sensor revealed good sensitivity to DA, UA, Xa, and HX with a succession linear range of 5–160 μM, 10–500 μM, 10–400 μM, and 2–300 μM, along with LODs of 0.65 μM, 0.80 μM, 1.20 μM, and 0.85 μM, respectively. Similarly, Yazdanparast et al. [96] also immobilized xanthine oxidase on a glassy carbon electrode (GCE) composed of a nanobiocomposite of multiwalled carbon nanotubes (MWCNT) and poly (L-aspartic acid) (Poly (L-Asp)) film. The demonstration of the biosensor was successfully conducted by analyzing xanthine from the fish meat with a detection limit of as low as 3.5 × 10−4 μM and a linear range of 0.001–0.004 μM and 0.005–50.0 μM. Song et al. [25] constructed a novel biosensor based on ZnIn2S4/UiO-66-NH2 modified glassy carbon electrode (GCE) to detect xanthine and hypoxanthine in assessing freshness of fish. Incorporation of UiO-66-NH2 improved the functionality of the biosensor and provide a good simultaneous detection of xanthine and hypoxanthine with wide linear ranges of 0.025–40 µM and 0.3–40 µM along with a low LOD of 0.0083 µM and 0.1 µM.
The aforementioned techniques used glassy carbon electrodes (GCE) as the host matrix. Glassy carbon electrodes (GCEs) are widely used in biosensors due to their unique physical and chemical properties. GCEs have a large surface area, which allows for a large number of biomolecules to be immobilized on the electrode surface, leading to an increase in the sensitivity and selectivity of the biosensor [97]. In addition, GCEs have a low background current, making them ideal for electrochemical measurements as they reduce interference from other sources and provide more accurate measurements [98]. GCEs are also chemically stable, meaning they are resistant to degradation and can withstand harsh conditions, making them suitable for use in biosensors [99]. Furthermore, GCEs are biocompatible and do not interfere with biological processes, making them ideal for use in biosensors as they do not affect the activity of the biomolecules being measured [100]. Additionally, GCEs have a wide potential window, allowing for the measurement of a wide range of electroactive species, making them suitable for use in biosensors for the measurement of a wide range of biomolecules [97]. Overall, the unique properties of GCEs make them a valuable choice for use in biosensors.
There have been several efforts to design biosensors for the detection of hypoxanthine, xanthine, and uric acid in fish samples. Vishnu et al. [101] synthesized an enzyme-free biosensor composed of an Ag/AgCl electrode and a preanodized 4B grade pencil graphite electrode (PGE) for this purpose. The biosensor, referred to as Ag/AgCl (4B-PGE*), demonstrated linear calibration plots in the ranges of 6–30 μM, 8–36 μM, and 3–21 μM for hypoxanthine, xanthine, and uric acid, respectively, with detection limits of 1.09 μM, 0.40 μM, and 0.17 μM. Additionally, Li et al. [102] designed a simultaneous detector for xanthine and hypoxanthine to assess fish freshness. The sensor was based on Cu-BTC frameworks modified with carbon paste electrodes (CPEs) and prepared using triethylamine, copper (II) nitrate, and 1,3,5-benzenetricarboxylic acid (H3BTC). The sensor showed good linearity in the ranges of 5–8000 nM and 10–10,000 nM for xanthine and hypoxanthine, respectively, with limits of detection (LODs) of 0.89 nM and 2.1 nM. Pierini et al. [39] proposed a simple, rapid, and inexpensive method for detecting hypoxanthine, xanthine, and uric acid in fish samples using an edge-plane pyrolytic graphite electrode (EPPGE). The method had linear ranges of 0.1 to 50 μM for hypoxanthine and xanthine, and of 0.1 to 25.0 μM for uric acid, with LODs of 0.08, 0.06, and 0.03 μM, respectively. The low detection limit of the biosensor makes it suitable for use in quality control of meat samples by the food industry. Thakur et al. [18] immobilized a polyaniline-wrapped titanium dioxide (PANI@TiO2) nanohybrid as the sensing material onto an indium tin oxide (ITO) electrode to create a biosensor for xanthine. The biosensor had a detection limit of 0.1 µM and a linear range of 1 to 100 µM. It also showed a rapid response time, requiring only 10 s to detect the presence of xanthine.
Table 2. Recent trends of electrochemical biosensors in detecting meat freshness and their analytical performance in food applications.
Table 2. Recent trends of electrochemical biosensors in detecting meat freshness and their analytical performance in food applications.
SensorDetection MethodNanomaterialsSamplesAnalytesLinear RangeLODReference
Nafion/XOD/TiO2-G/GCE sensorVoltammetryGraphene/titanium dioxide nanocomposite (TiO2-G)Pork tenderloinsHx20-512 μM9.5 μM[3]
XO-modified GLAD NiO electrodesConductometry-FishXa0.1–5 μM37 nM[19]
XOs/PANI@ TiO2/ITO electrodeDifferential pulse voltammetryPolyaniline-wrapped titanium dioxide (PANI@TiO2) nanohybridRohu (Labeo rohita) fishXa1–100 µM0.1 µM[18]
Au-PEDOT- fMWCNT/ GCEConductometryFunctionalized MWCNT-nanogoldFish meatUA
Xa
Hx
0.1–800 μM
0.05–175 μM
0.1–150 μM
199.3 nM
24.1 nM
90.5 nM
[20]
ZnIn2S4/UiO-66-NH2/GCEAmperometry-Large yellow croakerHx
Xa
0.3–40 µM
0.025–40 µM
0.1 µM
0.0083 µM
[25]
EPPGEAmperometry-FishHx
Xa
UA
0.1–50 μM
0.1–50 μM 0.1–25.0 μM
0.08 μM
0.06 μM
0.03 μM
[39]
XOD-Cu-MOFAmperometryMetal organic framework nanofibers (MOF)Chilled squid
Large yellow croaker
Hx
Xa
0.01–10 μM0.0023 μM
0.0064 μM
[83]
XODNPs/AuDifferential pulse voltammetry (DPV)Nanoparticles of xanthine oxidase (XODNPs)Fish meatXa0.01–1.0 μM0.01 μM[84]
Pt/PPy-pTS-XnOx/UCyclic voltammetry-Fish meatHx5 × 10−6–5 × 10−3 M5 × 10−6 M[85]
XO/nano-Au/c-MWCNTAmperometryScreen-printed multi–walled carbon nanotubes (c-MWCNT) gold particleFish and chicken meatXa2388.88 µA/cm2/nM1.14 nM[86]
XO/nano Ag–ZnO/PPy/PGECyclic voltammetrySilver-doped zinc oxide nanoparticle (nano Ag-ZnO)Sea bass fishXa0.06–0.6 μM0.07 μM[87]
MFPP/FPP/PtNPsAmperometryPlatinum nanoparticles (PtNPs)FishXa0.1–1.4 mM48 nM[88]
Co(TMA)MOF@CNFAmperometryCarbon nanofibers (CNFs)
Cobalt-metal organic framework (MOF)
Fish meatXa
UA
25–700 µM96.2 nM, 103.5 nM[90]
SnO2@CeO2-CoDifferential pulse voltammetryCerium oxide nanocrystals doped with cobalt heteroatoms (CeO2-Co) and Tin oxide (SnO2) nanorodsChickenXa25 nM–55 µM58 nM[91]
GCE/PEDOT:PSS-AuNPsVoltammetryFunctionalized gold nanoparticleFish and meatXa5.0 × 10−8–1.0 × 10−5 M3.0 × 10−8 M[94]
GCE/rGO/CS/Cr2O3AmperometryReduced graphene oxideFish meatDA
UA
Xa
Hx
5–160 μM
10–500 μM
10–400 μM
2–300 μM
0.65 μM
0.80 μM
1.20 μM
0.85 μM
[95]
XO/Poly(l-Asp)/MWCNT/GCE electrode
-
Cyclic voltammetry (CV)
-
Differential pulse voltammetry (DPV)
Multi-walled carbon nanotube (MWCNT)Fish meatXa0.001–0.004 μM3.5 × 10−4 μM[96]
Ag/AgCl (4B-PGE*)Amperometry-Freshly dead fishHx
Xa
UA
6–30 μM
8–36 μM
3–21 μM
1.09 μM
0.40 μM
0.17 μM
[101]
Cu-BTC/CPEAmperometry-FishHx5–8000 nM
2.0 nM[102]
In addition to the widely used glassy carbon electrodes, other electrode materials have also been widely employed as the host matrix in electrochemical biosensors, including pencil graphite electrodes, carbon paste electrodes, edge-plane pyrolytic graphite electrodes, and indium tin oxide. Pencil graphite electrodes, created from finely ground graphite, are commonly used as a reference electrode in electrochemical measurements [103]. Carbon paste electrodes, on the other hand, are created by mixing carbon powder with a binder, such as graphite or petroleum jelly, and forming the mixture into a paste [104]. These electrodes are often used in electrochemical sensors and biosensors because they have a large surface area and are easy to fabricate [105]. Edge-plane pyrolytic graphite electrodes, also known as EPPGE, are created from high-quality, highly ordered pyrolytic graphite and have a highly smooth and flat surface [106]. This makes them useful for electrochemical measurements that require a stable and low-noise reference electrode [107]. Meanwhile, indium tin oxide (ITO) electrodes are created from a transparent, conductive oxide of indium and tin and are commonly used in electrochemical sensors and biosensors because of their high conductivity and transparency. In terms of performance, pencil graphite electrodes have a relatively high resistance and may not be suitable for use in high-frequency or high-current applications [103]. Carbon paste electrodes have a higher conductivity than pencil graphite electrodes, but their performance can be affected by the binder used and the particle size of the carbon powder [104]. EPGE electrodes, on the other hand, have very low resistance and are highly stable, making them suitable for use in a wide range of electrochemical measurements, including high-frequency and high-current applications [106]. ITO electrodes have high conductivity and transparency, making them useful for applications where both electrical conductivity and optical transparency are required, such as electrochemical sensors and biosensors for in vitro and in vivo measurements [108,109]. Overall, the choice of electrode material will depend on the specific requirements of the electrochemical measurements being performed [108]. It is important to consider factors such as conductivity, stability, and compatibility with the measurement system when selecting an electrode [105].
Nowadays, researchers frequently employ nanomaterials on the host matrices of biosensors to improve their sensitivity and selectivity. Several nanoparticles have been employed in the development of the electrochemical biosensor, as can be seen in Table 2. For instance, Wang et al. [110] proposed a dual enzyme electrochemiluminescence sensor to assess the presence of inosine 5′-monophosphate (IMP) in meat. Silver nanoparticles (AgNPs) were obtained via reduction of luminol and were mixed with zeolite imidazole backbone-67 (ZIF-67) to successfully produce ZIF-67@AgNPs-Luminol powder. The prepared sensor showed a linear range of 0.003–25 g/L with a satisfactory LOD of 0.0017 g/L. Silver nanoparticles have high conductivity and surface-enhanced Raman scattering (SERS) activity, making them suitable for use in electrochemical sensing applications [111]. There are several potential advantages to using silver nanoparticles on MOFs for electrochemical biosensing. Firstly, the high conductivity of silver nanoparticles can improve the sensitivity of the biosensor, as it allows for faster electron transfer between the electrode and the analyte [112]. In addition, the SERS activity of silver nanoparticles can enhance the signal of the biosensor, allowing for the detection of trace amounts of analytes [113]. Secondly, the tunable pore size of MOFs can be used to selectively capture specific analytes based on their size [114], while the functionalization of the MOFs with biomolecules can allow for the selective detection of specific analytes [115]. The combination of these two factors can improve the selectivity of the biosensor. Finally, the high stability of MOFs under a wide range of conditions, combined with the high stability of silver nanoparticles [113], can result in a biosensor with stable performance over a long period of time [111]. However, it is important to consider factors such as the synthesis and stability of the silver nanoparticles as well as the compatibility of the MOFs with the silver nanoparticles [114] in order to optimize the performance of the biosensor.
Conductometry is a type of electrochemical biosensor that is often used to determine the concentration of ions in a solution and to study the properties of electrolytes. It is particularly useful for measurements where the concentration of ions is expected to vary widely [116]. In addition to amperometry and voltammetry techniques, conductometry is a simple and rapid technique that is well-suited for a range of applications. To illustrate the potential of conductometry, Sen and Sarkar [20] employed the technique to electrodeposit a nanogold-decorated PEDOT:TOS polymeric nanocomposite onto functionalized multiwalled carbon nanotubes (fMWCNTs). This process increased the conductivity of the synthesized film, which was then used to detect hypoxanthine, xanthine, and uric acid in human serum, urine, and fish samples. The film exhibited good sensitivity, with values of 1.73, 14.31, and 3.82 μA μM−1cm−2, as well as linear ranges of detection of 0.1–800, 0.05–175, and 0.1–150 μM, respectively. Additionally, the film had limits of detection (LODs) of 199.3, 24.1, and 90.5 nM for uric acid, xanthine, and hypoxanthine, respectively. It is worth noting that the incorporation of nanomaterials into host matrices can enhance the sensitivity and selectivity of biosensors. In summary, each of these techniques has its own advantages and limitations, and the most appropriate technique will depend on the specific requirements of the measurement. Amperometry is sensitive and useful for measuring low concentrations of ions, while voltammetry is versatile and useful for studying electrochemical reactions and developing sensors. On the other hand, conductometry is simple and rapid, and it is particularly well-suited for measuring ion concentrations over a wide range.

4.2. Optical Sensor

Optical sensors have attracted a great deal of attention among researchers for analytical applications, such as monitoring and evaluating the biological as well as the chemical substances. Optical sensor array technology offers visual adjustments that mimic human smell to detect, classify, and interpret complex gases and volatility based on chem-responsive colors. The optical sensor array is more objective than human olfaction and electronic noses and is not prone to interference, as human olfaction leads to subjective results depending on one’s preferences [117]. Additionally, optical sensor arrays have been increasingly implemented in food science and industry for their visualization, rapidity, and nondestruction in research. Optical sensors are related to the interaction of biorecognition elements, such as enzymes, antibodies, antigens, whole cells, or nucleic acids, with the optical field. Generally, optical biosensing is categorized into two general modes: (1) label-free: it detects a signal directly, and (2) label: it requires the use of a label and follows an optical signal generated by a colorimetric, fluorescent, or luminescent method, respectively [118]. Optical biosensors provide advantages over conventional techniques in offering real-time results, rapid analysis completion, high sensitivity and specificity, low concentration and amount of analyte required, a reusable sensor chip, and all of this in a cost-effective manner. Optical biosensors are widely implemented in various fields, including healthcare, environmental analyses, biotechnology industries, and the food industry.
Optical biosensors’ working principles are the same as those of electrochemical biosensors. An optical biosensor is a compact analytical device integrated with an optical transducer system that contains biorecognition sensing features. The fundamental objective of an optical biosensor is to generate a signal that is directly proportional to the amount and concentration of a measured analyte. The biomolecules used on the functionalized surface of optical biosensors can either be: (1) enzymes, (2) antibodies, (3) antigens, (4) whole cells and tissues, (5) nucleic acids, or (6) receptors. Biorecognition molecules are put in close proximity with the optical transducer, such as surface plasmon resonance (SPR), a refractometer, resonators, gratings, or interferometers, to detect the chemical interaction of biorecognition molecules with the targeted analytes [119,120]. Fluorescence analysis has become the most effective bioanalytical device as compared to other types of biosensors due to its inherent benefits, high sensitivity, and efficiency of anti-interference [121]. Table 3 summarizes the recent trends of optical biosensors in detecting meat freshness and their analytical performance in food applications.
Fluorescence optical sensors are a type of biosensor that uses the fluorescence of a substance to detect its presence and concentration. Fluorescence occurs when a substance absorbs light of a certain wavelength and then re-emits it at a longer wavelength. Fluorescence sensors measure the intensity of the emitted light, which is proportional to the concentration of the substance in the sample. Fluorescence sensors are widely used in various applications, including environmental monitoring, food and beverage testing, and medical diagnostics. They are sensitive to a wide range of wavelengths and can be used to detect substances that are not visible to the naked eye [122]. Hu et al. [123] developed a sensing platform based on aminofunctionalized metal-organic framework nanosheets with peroxidase mimic enzymes and fluorescence properties for the detection of hypoxanthine in fish samples. The NH2-Cu-MOF nanosheet showed a linear relationship with the concentration of hypoxanthine in the range of 10–2000 μM with 3.93 μM of the limit of detection. This biosensor was successfully applied to detect hypoxanthine in the fish samples with satisfactory results and has a promising prospect for target detection in food analysis. Additionally, Liu et al. [124] used a novel, simple, sensitive, and reliable fluorescence sensor based on S1 nuclease, FAM-labeled ssDNA (DNA-F), and graphene oxide (GO) to detect beef meat freshness in the presence of adenosine triphosphate (ATP). Under the optimal conditions, a linear correlation between the fluorescence and the ATP concentration from 20 μM to 3500 μM was obtained with a detection limit of 3.2 μM. Chen et al. [121] developed a fluorescence biosensor using platinum nanoparticles (Pt NPs), containing a peroxidase mimicking activity for rapid detection of hypoxanthine in aquatic products including fish, shrimp, and squid samples. A linear relationship was shown between the fluorescence intensity and the hypoxanthine concentration in the samples with values ranging between 8 μM and 2500 μM. The detection limit of the Pt NPs fluorescence biosensor was as low as 2.88 μM with excellent recovery rates of 103.94–109.00%.
Zhang et al. [10] developed a fluorometric assay using an AIE-active probe, TPE-HPro, and the fabrication of xanthine oxidase to detect hypoxanthine in artificial urine samples. The linear range of the quantification of hypoxanthine was up to 120 μM with a limit of detection of 1.2 μM, and it was proven to be matched with the endogenous hypoxanthine levels in human plasma and urine. The limit of detection of 1.2 μM is relatively low, indicating a high sensitivity of the biosensor. The linear range of up to 120 μM is relatively wide, indicating a good accuracy and precision of the biosensor in measuring the concentration of hypoxanthine over a wide range. Mou et al. [24] designed an orange emissive carbon dots (O-CDs) sensor with a high fluorescence quantum yield for the detection of hypoxanthine in fish. The fabricated O-CDs sensor demonstrated a linear range of 2–250 μM with a detection limit of 0.61 μM. The limit of detection of 0.61 μM is lower than that of the biosensor developed by Zhang et al. [10], indicating a higher sensitivity to the O-CDs sensor. The linear range of 2–250 μM is slightly narrower than that of the biosensor developed by Zhang et al. [10], indicating slightly lower accuracy and precision of the O-CDs sensor in measuring the concentration of hypoxanthine. Zhao et al. [125] determined hypoxanthine in fish using cysteine-functionalized copper nanoclusters (Cys-CuNCs). This fluorescence method showed a limit of detection and linearity of 0.7 μmol/L and 8–400 μmol/L, respectively. The limit of detection of 0.7 μmol/L is lower than those of the biosensors developed by Zhang et al. [10] and Mou et al. [24], indicating a higher sensitivity of the Cys-CuNCs sensor. The linear range of 8–400 μmol/L is slightly narrower than that of the biosensor developed by Zhang et al. [10] but wider than that of the biosensor developed by Mou et al. [24], indicating good accuracy and precision of the Cys-CuNCs sensor in measuring the concentration of hypoxanthine.
Xue et al. [126] constructed a novel, simple, and efficient xanthine biosensor to indicate the level of freshness of fish. The biosensor assay was composed of zinc oxide nanomaterials and xanthine oxidase, which were reported to provide specific and quantitative xanthine detection. The XOD@ZnO biosensor has been shown to have a wide linear range of 2.67 × 10z−6 to 2.67 × 10−4 mol L−1 with a sufficiently low detection limit of 1.30 × 10−10 mol L−1. The low detection limit and wide linear range of the XOD@ZnO biosensor indicate high sensitivity, accuracy, and precision in detecting and measuring the concentration of xanthine in fish samples. Luo et al. [127] designed a portable fluorescence/colorimeter hydrogel based on silver metallization to monitor the biogenic amines (BAs) in fish. The portable functional hydrogel was fabricated by using only silver ions and β-D-GP in the agarose gel. The detection limit of 2.77 × 10−9 mol dm−3 was calculated with a linear range of 28.5 × 10−9 to 114.9 × 10−9 mol dm−3. This method provides a simple, low-cost, and sensitive method for nondestructive, real-time monitoring of the fish’s freshness. The low detection limit and wide linear range of the portable functional hydrogel indicate high sensitivity, accuracy, and precision in detecting and measuring the concentration of BAs in fish samples. In terms of analytical performance, both the XOD@ZnO biosensor and the portable functional hydrogel have low detection limits and wide linear ranges, indicating high sensitivity, accuracy, and precision in detecting and measuring the concentrations of xanthine and BAs in fish samples, respectively. However, it is worth noting that the XOD@ZnO biosensor is specifically designed for the detection of xanthine, whereas the portable functional hydrogel is designed for the detection of BAs, which are a group of nitrogenous compounds that are produced during the decomposition of proteins in fish and are used as indicators of fish freshness. Therefore, the specific analytical performance of the XOD@ZnO biosensor and the portable functional hydrogel should be compared within the context of their respective applications.
A colorimeter is a type of optical sensor that uses colorimetry, a method of measuring the concentration of a substance by measuring the intensity of its color, for detecting and quantify the presence of a substance in a sample. They are simple, inexpensive, and easy to use, and they can detect a wide range of substances, including chemicals, biomolecules, and pathogens [128]. Hsu et al. [129] proposed silver nanoplates (AgP) as the colorimetric sensing platform to detect xanthine in fish meat. Detection of xanthine was conducted via the etching process of AgP particles/aggregation/fusion steps, which caused a change in color from blue to gray. The linear response range of xanthine was from 0.15 μM to 0.60 μM, with a satisfactory limit of detection (LOD) of 0.011 μM. The low LOD and narrow linear range of the AgP colorimeter indicate high sensitivity and good accuracy and precision in detecting and measuring the concentration of xanthine in fish meat. Chen et al. (2017) developed a simple, visual, and economical biosensor fabricated with gold nanorods (GNRs) to evaluate the freshness of fish with the naked eye. Hypoxanthine in fish samples is dissolved in oxygen, thus, reacting with xanthine oxidase to produce H2O2 in the presence of Fe2+. The linear range of hypoxanthine in GNRS/SPR is from 0.05 mM to 0.63 mM with a correlation coefficient of 0.9945. However, it has been shown that hypoxanthine is not only found in meat but also in urine samples. The narrow linear range and high correlation coefficient of the GNRS/SPR colorimeter indicate good accuracy and precision in detecting and measuring the concentration of hypoxanthine in fish samples. Mooltongchun and Teepoo [130] developed a fast, sensitive, and cost-effective paper-based colorimetric biosensor (lab-on-paper) for enzyme catalytic reactions (xanthine oxidase) to detect hypoxanthine in fresh and processed meat samples within 5 min. The technique has been validated against spectrophotometric detection and has shown good accuracy, as well as the fact that no specialized tools are needed, providing an alternative to traditional techniques. The linear range of hypoxanthine is 5–40 mg/L with a detection limit of 1.8 mg/L. The low detection limit and wide linear range of the lab-on-paper colorimeter indicate high sensitivity and good accuracy and precision in detecting and measuring the concentration of hypoxanthine in fresh and processed meat samples. In terms of analytical performance, all three colorimeters described previously have good sensitivity, accuracy, and precision in detecting and measuring the concentration of xanthine or hypoxanthine in different types of samples. The AgP colorimeter has a low LOD and narrow linear range, indicating high sensitivity and good accuracy and precision in detecting xanthine in fish meat. The GNRS/SPR colorimeter has a narrow linear range and a high correlation coefficient, indicating good accuracy and precision in detecting hypoxanthine in fish samples. The lab-on-paper colorimeter has a low detection limit and a wide linear range, indicating high sensitivity and good accuracy and precision in detecting hypoxanthine in fresh and processed meat samples.
Wang et al. [131] used the peroxidase-like activity of cobalt-doped graphite phase carbon nitride (Co-doped-g-C3N4) as a colorimetric method in determining the presence of hypoxanthine (Hx) in aquatic products, such as fish. Based on the research, Hx can be directly detected using the spectral absorbance at 652 nm with a limit of detection (LOD) of 1.84 mg/kg and a linear range of 2.50–153.1 mg/kg. The low LOD and wide linear range of the Co-doped-g-C3N4 colorimeter indicate high sensitivity and good accuracy and precision in detecting and measuring the concentration of Hx in aquatic products. Mustafa and Andreescu [132] synthesized a robust, reagentless colorimetric device for monitoring the freshness of meat and predicting spoilage by measuring the level of hypoxanthine. The study entrapped xanthine oxidase and nitro blue tetrazolium chloride (NBT) in a sol–gel biohybrid, resulting in a low LOD of 3.7 μM for hypoxanthine. The low LOD of the reagentless colorimetric device indicates high sensitivity in detecting hypoxanthine in meat samples. Mustafa et al. [133] fabricated an enzyme mimetic nanocatalyst with multiple functions as a peroxidase mimic, a chromogenic indicator, and a redox amplifier, cerium nanoparticles (CeNPs), and a xanthine oxidase (XOD)-based biosensor for monitoring and measuring hypoxanthine. CeNPs and XOD were immobilized on silanized paper and showed a LOD of 15 μM with a linear range up to 800 μM. The low LOD and wide linear range of the CeNPs and XOD colorimeter indicate a high sensitivity and good accuracy and precision in detecting and measuring the concentration of hypoxanthine.
Guo et al. [52] also demonstrated a colorimetric method for the detection of hypoxanthine (Hx) in sea bass fish based on the peroxidase activity of xanthine oxidase grade I ammonium sulfate suspension (XOD-ASS). This method has good selectivity, is low-cost, and is easy to prepare. The LOD was shown to be 6.93 μM, and the technique displayed a good linear relationship in the range from 20 to 200 μM. The color changes from colorless to blue with the presence of H2O2. The low LOD and wide linear range of the XOD-ASS colorimeter indicate high sensitivity and good accuracy and precision in detecting and measuring the concentration of Hx in sea bass. Ding et al. [134] developed portable silver-doped Prussian blue nanoparticle hydrogels (SPB NPs) incorporated with agarose hydrogels for trimethylamine (TMA) detection in shrimp and fish. The linear range was shown to be from 0.21 to 0.54 ppm. The use of a smartphone and hand-held thermal imager significantly enhances the mobility and usability of on-site monitoring. The narrow linear range of the SPB NPs colorimeter indicates good accuracy and precision in detecting and measuring the concentration of TMA in shrimp and fish. In terms of analytical performance, all five colorimeters described previously have good sensitivity, accuracy, and precision in detecting and measuring the concentration of different substances in various types of samples. The Co-doped-g-C3N4 reagentless, CeNPs, XOD, XOD-ASS, and SPB NPs colorimeters have low LODs and wide linear ranges, indicating high sensitivity, good accuracy, and precision in detecting and measuring the concentrations of Hx and TMA, respectively. The reagentless colorimeter has a low LOD and no specified linear range, indicating high sensitivity in detecting hypoxanthine in meat samples. Overall, these colorimeters provide reliable and efficient methods for detecting and measuring the concentration of various substances in different types of samples, making them useful tools in various applications, such as food safety, biomedical diagnostics, and environmental monitoring.
Table 3. Recent trends of optical biosensors in detecting meat freshness and their analytical performance in food applications.
Table 3. Recent trends of optical biosensors in detecting meat freshness and their analytical performance in food applications.
SensorDetection MethodNanomaterialsSampleAnalyteLinear RangeLODReferences
Fluorescent-TPE- HPro/XOColorimetric-FishHx5–120 μM1.2 μM[10]
O-CDsColorimetricCarbon dotsFishHx2–250 µM0.61 µM[24]
XOD-ASSFluorescence-FishHx20–100 μM6.93 μM[52]
Fluorescent-PtNPsFluorescencePlatinum nanoparticlesFish, shrimp, squidHx8–2500 μM2.88 μM[121]
Fluorescent-NH2-Cu-MOF nanosheetFluorescenceMetal organic frameworks (MOF) nanosheetFishHx10–2000 μM3.93 μM[123]
DNA-F/GOFluorescenceGraphene oxide (GO)BeefATP20–3500 μM3.2 μM[124]
Cys-CuNCsFluorescenceCopper nanoclustersFishHx8–400 μmol/L0.7 μmol/L[125]
XOD@ZnO nanomaterialsColorimetricZinc oxide (ZnO) nanomaterialsFishXa2.67 × 10−6–2.67 × 10−4
mol L−1
1.30 × 10−10 mol L−1[126]
Silver ions and β-D-GPFiber-optic-FishBAs28.5–114.9 × 10−9 mol dm−32.77 × 10−9 mol dm−3[127]
AgPColorimetricSilver nanoplates (AgP)FishXa0.15–0.60 μM0.011 μM[129]
Paper-based colorimetric biosensorFluorescence-Pork, chicken, fish meat and fish sauceHx5–40 mg/L1.8 mg/L[130]
Co-doped-g-C3N4Colorimetric-FishHx2.50–153.1 mg/kg1.84 mg/kg[131]
XO/NBT/sol–gel biohybridColorimetric-Tilapia fishHx-3.7 μM[132]
CeNPs/XOD/silanized paperColorimetricCerium oxide nanoparticles (CeNPs)Degraded fishHx800 μM15 μM[133]
SPB NPs/Agarose hydrogelFluorescence/ colorimetricSilver-doped prussian blue nanoparticles (SPB NPs)Shrimp, fishTMA0.21–0.54 ppm-[134]
Colorimetric-CTAB- Au nanorodsFluorescenceGold nanorods (GNrs)FishHx0–1130 μM-[135]

5. Comparison between Conventional Techniques and Nanotechnology Biosensor

Several conventional and biosensor techniques have been discussed in the earlier part. Both techniques can be used to monitor, detect, and evaluate food samples in the food industry. The use of conventional techniques is indeed an indisputable method due to its high selectivity and sensitivity, as discussed above. However, there are some limitations in guaranteeing the on-field and real-time monitoring of the food samples in order to maintain the safety and quality of the food. For instance, capillary electrophoresis has limited utility due to its high cost and low reproducibility; only a select few companies manufacture capillary electrophoresis equipment [136,137]. High-performance liquid chromatography (HPLC) is a time-consuming and laborious method that can separate individual components from complex mixtures, but it has not been successful in retaining these neutral or ionic polar compounds, and it requires highly trained personnel and extensive sample pretreatment [138]. The absorption spectra for Hx, X, and UA all showed significant overlap, making the simultaneous determination of all three components in a biological sample a challenging task [139]. Numerous methods have been reported to enable low-cost, user-friendly, rapid, dependable, selective, and sensitive hypoxanthine detection, which would help address the aforementioned issues.
Nanotechnology biosensors are reported to have few incontestable advantages over conventional techniques, especially with the fabrication of nanomaterials that enhanced the electrochemically active surface area and the efficiency of electron transfer in biosensor sensing systems [140,141], making them particularly useful for the immobilization of enzymes. Additionally, the application of nanotechnology to the analytical performance of electrochemical sensors has vastly improved in terms of low detection limits, broad linear ranges, and high sensitivities. These are the several advantages of nanobiosensors: (1) good selectivity with direct detection of samples or analytes without sample pretreatments or shorten the sample pretreatment process, (2) fast response time within a few seconds to few minutes, (3) low cost as compared to conventional techniques, which required huge cost of instruments for maintenance, (4) perspectives for miniaturization, (5) allow portability, (6) satisfactory analytical performances parameters, and (7) does not required trained personnel to handle equipment or instruments.
In comparing the analytical performance of conventional techniques and nanotechnology-based biosensors in detecting meat freshness (Table 4), it is evident that both types of techniques have good sensitivity and accuracy in detecting various analytes that are indicative of meat freshness. However, there are some differences in the analytical performance of these two types of techniques. One key difference is the linear range of detection. In general, nanotechnology-based biosensors tend to have wider linear ranges of detection compared to conventional techniques. For example, the linear range of detection for xanthine in fish meat using amperometry (XODNPs/Au) is 0.01–1.0 μM, while the linear range of detection using HPLC-UV is 0.05–300 mg/L. Similarly, the linear range of detection for hypoxanthine in fish using fluorescence-NH2-Cu-MOF nanosheet is 10–2000 μM, while the linear range of detection using HPLC-UV is 0.05–300 mg/L. This wider linear range of detection may make nanotechnology-based biosensors more suitable for detecting a wider range of analyte concentrations. Another difference is the limit of detection (LOD). In general, nanotechnology-based biosensors tend to have lower LODs compared to conventional techniques. For example, the LOD for xanthine in fish meat using amperometry (XODNPs/Au) is 0.01 μM, while the LOD using HPLC-UV is 0.0774 mg/L. Similarly, the LOD for hypoxanthine in fish using fluorescence-NH2-Cu-MOF nanosheets is 3.93 μM, while the LOD using HPLC-UV is 0.0555 mg/L (based on Table 4). This lower LOD may make nanotechnology-based biosensors more suitable for detecting trace levels of analytes.
In conclusion, both conventional techniques and nanotechnology-based biosensors have good sensitivity and accuracy in detecting various analytes in meat samples, but there are some differences in their analytical performance. Nanotechnology-based biosensors tend to have wider linear ranges of detection and lower limits of detection compared to conventional techniques. This may make them more suitable for detecting a wider range of analyte concentrations and trace levels of analytes, respectively. However, it is important to note that the choice of technique ultimately depends on the specific requirements and constraints of the application, and both types of techniques have their own advantages and limitations.

6. Conclusion and Future Perspectives

In conclusion, the use of nanotechnology-based biosensors for the assessment of meat freshness offers several advantages over traditional methods. These sensors are highly sensitive and specific and are able to detect very low concentrations of contaminants and distinguish between different types of purine derivatives. They also have a rapid response time, providing results in a matter of minutes or even seconds, which allows for more efficient and effective monitoring of meat products. Additionally, nanotechnology-based biosensors are portable and easy to use, making them well-suited for on-site testing in food processing plants or other settings.
However, while the use of these sensors has the potential to revolutionize the way we assess meat freshness, it is important to consider the potential challenges and limitations. One potential concern is the cost of purchasing and maintaining these sensors, which may be more expensive than traditional techniques. It is also important to consider the potential impact on the workforce, as the widespread adoption of these sensors could potentially lead to job losses in certain sectors. Overall, it is clear that the world is well-prepared for the lightning-fast pace of nanotechnology-based biosensors for the assessment of meat freshness, but it is important to approach their adoption with caution and consideration of all stakeholders.

Author Contributions

W.X.L.F. drafted the manuscript and collected the data. K.R., and N.H. developed the framework, finalized, and supervised the research. N.M.N.‘A., K.W.Y., and J.M.V. conceived the study and participated in its design and coordination. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors would like to thank all the researchers involved in this project. The work was supported by a grant from Universiti Malaysia Sabah, UMSGreat scheme (Grant No: GUG0434-1/2020).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bonnet, C.; Bouamra-Mechemache, Z.; Réquillart, V.; Treich, N. Regulating meat consumption to improve health, the environment and animal welfare. Food Policy 2020, 97, 101847. [Google Scholar] [CrossRef]
  2. Erna, K.H.; Rovina, K.; Mantihal, S. Current Detection Techniques for Monitoring the Freshness of Meat-Based Products: A Review. J. Package. Technol. Res. 2021, 5, 127–141. [Google Scholar] [CrossRef]
  3. Albelda, J.A.; Uzunoglu, A.; Santos, G.N.C.; Stanciu, L.A. Graphene-titanium dioxide nanocomposite based hypoxanthine sensor for assessment of meat freshness. Biosens. Bioelectron. 2017, 89, 518–524. [Google Scholar] [CrossRef] [PubMed]
  4. Díaz, F.; Díaz-Luis, A.; Sierra, V.; Diñeiro, Y.; González, P.; García-Torres, S.; Oliván, M. What functional proteomic and biochemical analysis tell us about animal stress in beef? J. Proteom. 2020, 218, 103722. [Google Scholar] [CrossRef] [PubMed]
  5. Hong, H.; Regenstein, J.M.; Luo, Y. The importance of ATP-related compounds for the freshness and flavor of post-mortem fish and shellfish muscle: A review. Crit. Rev. Food Sci. Nutr. 2017, 57, 1787–1798. [Google Scholar] [CrossRef] [PubMed]
  6. Karim, N.U.; Kennedy, J.T.; Linton, M.; Patterson, M.; Watson, S.; Gault, N. Determination of nucleotide and enzyme degradation in haddock (Melanogrammus aeglefinus) and herring (Clupea harengus) after high pressure processing. PeerJ 2019, 7, 7527. [Google Scholar] [CrossRef] [PubMed]
  7. Hwang, J.H.; Kim, Y.; Choi, H.; Lee, K.G. ATP degradation products as freshness indicator of flatfish during storage. Food Sci. Biotechnol. 2019, 28, 1891–1897. [Google Scholar] [CrossRef]
  8. Zhang, Y.; Gao, X.; Ye, Y.; Shen, Y. Fe-Doped polydopamine nanoparticles with peroxidase-mimicking activity for the detection of hypoxanthine related to meat freshness. Analyst 2022, 147, 956–964. [Google Scholar] [CrossRef]
  9. Chen, J.; Kong, Q.; Sun, Z.; Liu, J. Freshness analysis based on lipidomics for farmed Atlantic salmon (Salmo salar L.) stored at different times. Food Chem. 2022, 373, 131564. [Google Scholar] [CrossRef]
  10. Zhang, Z.; Kwok, R.T.; Yu, Y.; Tang, B.Z.; Ng, K.M. Aggregation-induced emission luminogen-based fluorescence detection of hypoxanthine: A probe for biomedical diagnosis of energy metabolism-related conditions. J. Mater. Chem. B 2018, 6, 4575–4578. [Google Scholar] [CrossRef]
  11. Guo, X.; Wang, X.; Huang, D.; Zhang, J.; Xu, D.; Yang, W.; Huang, T. Method study on determination of total purine content in fish meat by diazotization reaction combined with SERS. LWT 2020, 123, 109027. [Google Scholar] [CrossRef]
  12. Jia, W.; Fan, Z.; Shi, Q.; Zhang, R.; Wang, X.; Shi, L. LC-MS-based metabolomics reveals metabolite dynamic changes during irradiation of goat meat. Int. Food Res. J. 2021, 150, 110721. [Google Scholar] [CrossRef]
  13. Daldal, Y.D.; Demiralay, E.Ç. Chromatographic and UV–visible spectrophotometric pKa determination of some purine antimetabolites. J. Mol. Liq. 2020, 317, 113930. [Google Scholar] [CrossRef]
  14. Mathew, M.R.; Kumar, K.G. Poly (Amino Hydroxy Naphthalene Sulphonic Acid) Modified Glassy Carbon Electrode; An Effective Sensing Platform for the Simultaneous Determination of Xanthine and Hypoxanthine. J. Electrochem. Soc. 2020, 167, 047519. [Google Scholar] [CrossRef]
  15. Dervisevic, M.; Dervisevic, E.; Şenel, M. Recent progress in nanomaterial-based electrochemical and optical sensors for hypoxanthine and xanthine. A review. Mikrochim. Acta 2019, 186, 749. [Google Scholar] [CrossRef] [PubMed]
  16. Vlassa, M.; Filip, M.; Dragomir, C. Simultaneous quantifications of four purine derivatives biomarkers in cow milk by SPE HPLC-DAD. Czech J. Food Sci. 2021, 39, 122–130. [Google Scholar] [CrossRef]
  17. Nanda, P.K.; Bhattacharya, D.; Das, J.K.; Bandyopadhyay, S.; Ekhlas, D.; Lorenzo, J.M.; Gagaoua, M. Emerging Role of Biosensors and Chemical Indicators to Monitor the Quality and Safety of Meat and Meat Products. Chemosens 2022, 10, 322. [Google Scholar] [CrossRef]
  18. Thakur, D.; Pandey, C.M.; Kumar, D. Highly Sensitive Enzymatic Biosensor Based on Polyaniline-Wrapped Titanium Dioxide Nanohybrid for Fish Freshness Detection. Appl. Biochem. Biotechnol. 2022, 194, 3765–3778. [Google Scholar] [CrossRef] [PubMed]
  19. Tripathi, A.; Elias, A.L.; Jemere, A.B.; Harris, K.D. Amperometric Determination of Xanthine Using Nanostructured NiO Electrodes Loaded with Xanthine Oxidase. ACS Food Sci. Technol. 2022, 2, 1307–1317. [Google Scholar] [CrossRef]
  20. Sen, S.; Sarkar, P. A simple electrochemical approach to fabricate functionalized MWCNT-nanogold decorated PEDOT nanohybrid for simultaneous quantification of uric acid, xanthine and hypoxanthine. Anal. Chim. Acta 2020, 1114, 15–28. [Google Scholar] [CrossRef]
  21. Wang, G.; Sun, J.; Yao, Y.; An, X.; Zhang, H.; Chu, G.; Liu, Y. Detection of Inosine Monophosphate (IMP) in meat using double-enzyme sensor. Food Anal. Methods 2020, 13, 420–432. [Google Scholar] [CrossRef]
  22. Tan, J.; Liu, L.; Li, F.; Chen, Z.; Chen, G.Y.; Fang, F.; Guo, J.; He, M.; Zhou, X. Screening of Endocrine Disrupting Potential of Surface Waters via an Affinity-Based Biosensor in a Rural Community in the Yellow River Basin, China. Environ. Sci. Technol. 2022, 56, 14350–14360. [Google Scholar] [CrossRef]
  23. Memon, A.G.; Xing, Y.; Zhou, X.; Wang, R.; Liu, L.; Zeng, S.; He, M.; Ma, M. Ultrasensitive colorimetric aptasensor for Hg2+ detection using Exo-III assisted target recycling amplification and unmodified AuNPs as indicators. J. Hazard. Mater. 2020, 384, 120948. [Google Scholar] [CrossRef] [PubMed]
  24. Mou, Z.; Gao, Z.; Hu, Y. Orange emissive carbon dots for fluorescent determination of hypoxanthine in fish. SAA 2022, 269, 120734. [Google Scholar] [CrossRef] [PubMed]
  25. Song, D.; Chen, Q.; Zhai, C.; Tao, H.; Zhang, L.; Jia, T.; Zhu, B. Label-Free ZnIn2S4/UiO-66-NH2 Modified Glassy Carbon Electrode for Electrochemically Assessing Fish Freshness by Monitoring Xanthine and Hypoxanthine. Chemosens 2022, 10, 158. [Google Scholar] [CrossRef]
  26. Liu, R.; Warner, R.D.; Zhou, G.; Zhang, W. Contribution of nitric oxide and protein S-nitrosylation to variation in fresh meat quality. Meat Sci. 2018, 144, 135–148. [Google Scholar] [CrossRef]
  27. Cenci-Goga, B.T.; Iulietto, M.F.; Sechi, P.; Borgogni, E.; Karama, M.; Grispoldi, L. New trends in meat packaging. Microbiol. Res. 2020, 11, 56–67. [Google Scholar] [CrossRef]
  28. Mohammed, H.H.H.; Jin, G.; Ma, M.; Khalifa, I.; Shukat, R.; Elkhedir, A.E.; Noman, A.E. Comparative characterization of proximate nutritional compositions, microbial quality and safety of camel meat in relation to mutton, beef, and chicken. LWT 2020, 118, 108714. [Google Scholar] [CrossRef]
  29. Johnson, J.; Atkin, D.; Lee, K.; Sell, M.; Chandra, S. Determining meat freshness using electrochemistry: Are we ready for the fast and furious? Meat Sci. 2019, 150, 40–46. [Google Scholar] [CrossRef]
  30. Álvarez, S.; Mullen, A.M.; Hamill, R.; O’Neill, E.; Álvarez, C. Dry-aging of beef as a tool to improve meat quality. Impact of processing conditions on the technical and organoleptic meat properties. Adv. Food Nutr. Res. 2021, 95, 97–130. [Google Scholar] [CrossRef]
  31. Rey, A.I.; Menoyo, D.; Segura, J.; López-Bote, C.J.; Calvo, L. Combination of dietary glycaemic index and fasting time prior to slaughter as strategy to modify quality of pork. Meat Sci. 2020, 161, 108013. [Google Scholar] [CrossRef]
  32. Chauhan, S.S.; England, E.M. Postmortem glycolysis and glycogenolysis: Insights from species comparisons. Meat Sci. 2018, 144, 118–126. [Google Scholar] [CrossRef] [PubMed]
  33. Shi, C.; Cui, J.; Qin, N.; Luo, Y.; Lu, H.; Wang, H. Effect of ginger extract and vinegar on ATP metabolites, IMP-related enzyme activity, reducing sugars and phosphorylated sugars in silver carp during postslaughter storage. Int. J. Food Sci. 2017, 52, 413–423. [Google Scholar] [CrossRef]
  34. Rongsheng, Z.; Huaizhong, W.; Song, L.; Yanping, W.; Hongmei, H. Deposition Pattern of Inosine Monophosphate (IMP) in Pig Muscle during Cold Storage. Anim. Feed Sci. 2017, 9, 197–218. [Google Scholar] [CrossRef]
  35. Feng, X.; Moon, S.H.; Lee, H.Y.; Ahn, D.U. Effect of irradiation on the degradation of nucleotides in turkey meat. LWT 2016, 73, 88–94. [Google Scholar] [CrossRef]
  36. Lin, W.C.; He, Y.M.; Shi, C.; Mu, C.K.; Wang, C.L.; Li, R.H.; Ye, Y.F. ATP catabolism and bacterial succession in postmortem tissues of mud crab (Scylla paramamosain) and their roles in freshness. Int. Food Res. J. 2022, 155, 110992. [Google Scholar] [CrossRef]
  37. Ebata, K.; Yamashita, Y.; Inohara, K.; Fuwa, S.; Kimura, I.; Tamotsu, S.; Shinmachi, T. Evaluation of Muscle Post-mortem Changes of Japanese Anchovy Engraulis japonicus and Round Herring Etrumeus teres and Recovery of ATP Concentration of Japanese Anchovy Following Brief Rest in a Fish Cage. J. Fish. Eng. 2020, 56, 149–158. [Google Scholar] [CrossRef]
  38. Huang, Z.; Zhang, J.; Gu, Y.; Cai, Z.; Feng, X.; Yang, C.; Xin, G. Research progress on inosine monophosphate deposition mechanism in chicken muscle. Crit. Rev. Food Sci. Nutr. 2022, 62, 1062–1078. [Google Scholar] [CrossRef]
  39. Pierini, G.D.; Robledo, S.N.; Zon, M.A.; Di Nezio, M.S.; Granero, A.M.; Fernandez, H. Development of an electroanalytical method to control quality in fish samples based on an edge plane pyrolytic graphite electrode. Simultaneous determination of hypoxanthine, xanthine and uric acid. Microchem. J. 2018, 138, 58–64. [Google Scholar] [CrossRef]
  40. Li, J.; Zhou, G.; Xue, P.; Dong, X.; Xia, Y.; Regenstein, J.; Sun, L. Spoilage microbes’ effect on freshness and IMP degradation in sturgeon fillets during chilled storage. Food Biosci. 2021, 41, 101008. [Google Scholar] [CrossRef]
  41. Min, J.G.; Joung, B.C.; Jung, W.Y. Postmortem Changes in Spinal Cord-damaged Olive Flounder (Paralichthys olivaceus). J. Food Nutr. Res. 2019, 7, 500–505. [Google Scholar] [CrossRef]
  42. Yoshioka, T.; Konno, Y.; Konno, K. Below-zero storage of fish to suppress loss of freshness. Fish. Sci. 2018, 85, 601–609. [Google Scholar] [CrossRef]
  43. Larashinda, M.; Sayuti, K.; Yenrina, R.; Refdi, C.W. Purine Content in Various Type of Gulai as Specialty Food of West Sumatra. IJPSAT 2020, 21, 109–114. [Google Scholar] [CrossRef]
  44. Takayanagi, F.; Fukuuchi, T.; Yamaoka, N.; Kaneko, K. Measurement of the total purine contents and free nucleosides, nucleotides, and purine bases composition in Japanese anchovies (Engraulis japonicus) using high-performance liquid chromatography with UV detection. Nucleos. Nucleat. Nucl. 2020, 39, 1458–1464. [Google Scholar] [CrossRef]
  45. Qu, X.; Sui, J.; Mi, N.; Lin, H. Determination of four different purines and their content change in seafood by high-performance liquid chromatography. J. Sci. Food Agric. 2017, 97, 520–525. [Google Scholar] [CrossRef] [PubMed]
  46. Felisiak, K.; Szymczak, M.; Kołakowski, E. Identification of non-protein nitrogen compounds separated by CZE without derivatization from TCA extract from salted herring meat. J. Food Compos. Anal. 2019, 77, 108–114. [Google Scholar] [CrossRef]
  47. Ali, N.S.M.; Zabidi, A.R.; Manap, M.N.A.; SMSNS, Z.; Yahaya, N. Effect of different slaughtering methods on metabolites of broiler chickens using Ultra High-Performance Liquid Chromatography-Time of Flight-Mass Spectrometry (UHPLC-TOF-MS). Food Res. 2020, 4, 133–138. [Google Scholar] [CrossRef]
  48. Zheng, Y.; Li, X.; Chen, X.; Cai, Z.; Zhao, H. Simultaneous determination of amino acids, purines and derivatives in serum by ultrahigh-performance liquid chromatography/tandem mass spectrometry. RCM 2019, 33, 81–88. [Google Scholar] [CrossRef]
  49. Ueda, S.; Yamanoue, M.; Sirai, Y.; Iwamoto, E. Exploring the Characteristic Aroma of Beef from Japanese Black Cattle (Japanese Wagyu) via Sensory Evaluation and Gas Chromatography-Olfactometry. Metabolites 2021, 11, 56. [Google Scholar] [CrossRef]
  50. Chang, W.C.W.; Wu, H.Y.; Yeh, Y.; Liao, P.C. Untargeted foodomics strategy using high-resolution mass spectrometry reveals potential indicators for fish freshness. Anal. Chim. Acta 2020, 1127, 98–105. [Google Scholar] [CrossRef]
  51. Dibirasulaev, M.; Belozerov, G.; Arkhipov, L.; Stoyanova, L. Quick and simple spectrophotometric method of identification of the thermal state of meat on the basis of composition and content of free nucleotides. Food Sci. Nutr. 2018, 9, 572–583. [Google Scholar] [CrossRef]
  52. Guo, C.; You, S.; Li, C.; Chen, T.; Wang, X. One-Step and Colorimetric Detection of Fish Freshness Indicator Hypoxanthine Based on the Peroxidase Activity of Xanthine Oxidase Grade I Ammonium Sulfate Suspension. Front. Microbiol. 2021, 12, 791227. [Google Scholar] [CrossRef]
  53. Fukuuchi, T.; Iyama, N.; Yamaoka, N.; Kaneko, K. Simultaneous quantification by HPLC of purines in umami soup stock and evaluation of their effects on extracellular and intracellular purine metabolism. Nucleos. Nucleat. Nucl. 2018, 37, 273–279. [Google Scholar] [CrossRef]
  54. Larashinda, M.; Sayuti, K.; Yenrina, R.; Refdi, C.W. Identification of Purine Content in Various Processed Foods of Chicken as Specialty Food of West Sumatra. In Proceedings of the IOP Conference Series: Earth and Environmental Science, Phuket, Thailand, 18–21 October 2019. [Google Scholar] [CrossRef]
  55. Wu, M.; Zhang, W.; Shen, X.; Wang, W. Simultaneous Determination of Purines and Uric Acid in Chinese Chicken Broth Using TFA/FA Hydrolysis Coupled with HPLC-VWD. Foods 2021, 10, 2814. [Google Scholar] [CrossRef]
  56. Xiao, L.; Sha, W.; Tao, C.; Hou, C.; Xiao, G.; Ren, J. Effect on purine releasement of Lentinus edodes by different food processing techniques. Food Chem. X 2022, 13, 100260. [Google Scholar] [CrossRef]
  57. Zhu, P.; Wang, S.; Wang, J.; Zhou, L.; Shi, P. A capillary zone electrophoresis method for adenine nucleotides analysis in Saccharomyces cerevisiae. J. Chromatogr. B 2016, 1008, 156–163. [Google Scholar] [CrossRef]
  58. Klampfl, C.W.; Himmelsbach, M.; Buchberger, W.; Klein, H. Determination of purines and pyrimidines in beer samples by capillary zone electrophoresis. Anal. Chim. Acta 2002, 454, 185–191. [Google Scholar] [CrossRef]
  59. Mu, G.; Luan, F.; Xu, L.; Hu, F.; Liu, H.; Gao, Y. Determination of purines in soybean milk by capillary electrophoresis in comparison with high performance liquid chromatography. Anal. Methods 2012, 4, 3386–3391. [Google Scholar] [CrossRef]
  60. Medina, D.A.V.; Borsatto, J.V.B.; Maciel, E.V.S.; Lancas, F.M. Current role of modern chromatography and mass spectrometry in the analysis of mycotoxins in food. TRAC-Trends Analyt. Chem. 2021, 135, 116156. [Google Scholar] [CrossRef]
  61. Hu, Q.; Sun, Y.; Yuan, P.; Lei, H.; Zhong, H.; Wang, Y.; Tang, H. Quantitative structure-retention relationship for reliable metabolite identification and quantification in metabolomics using ion-pair reversed-phase chromatography coupled with tandem mass spectrometry. Talanta 2022, 238, 123059. [Google Scholar] [CrossRef]
  62. Hou, C.; Xiao, G.; Amakye, W.K.; Sun, J.; Xu, Z.; Ren, J. Guidelines for purine extraction and determination in foods. Food Front. 2021, 2, 557–573. [Google Scholar] [CrossRef]
  63. Li, C.; Hao, J.; Wu, K. Triethylamine-controlled Cu-BTC frameworks for electrochemical sensing fish freshness. Anal. Chim. Acta 2019, 1085, 68–74. [Google Scholar] [CrossRef] [PubMed]
  64. Ramirez, D.A.; Locatelli, D.A.; González, R.E.; Cavagnaro, P.F.; Camargo, A.B. Analytical methods for bioactive sulfur compounds in Allium: An integrated review and future directions. J. Food Compos. Anal. 2017, 61, 4–19. [Google Scholar] [CrossRef]
  65. Masci, M.; Zoani, C.; Nevigato, T.; Turrini, A.; Jasionowska, R.; Caproni, R.; Ratini, P. Authenticity assessment of dairy products by Capillary Electrophoresis. Electrophoresis 2022, 43, 340–354. [Google Scholar] [CrossRef] [PubMed]
  66. Felisiak, K.; Szymczak, M. Use of rapid capillary zone electrophoresis to determine amino acids indicators of herring ripening during salting. Foods 2021, 10, 2518. [Google Scholar] [CrossRef] [PubMed]
  67. Shrestha, B. Nanotechnology for Biosensor Applications. In Sustainable Nanotechnology for Environmental Remediation; Elsevier: Amsterdam, The Netherlands, 2022; Volume 1, pp. 513–531. [Google Scholar] [CrossRef]
  68. Huang, X.; Zhu, Y.; Kianfar, E. Nano biosensors: Properties, applications and electrochemical techniques. J. Mater. Res. Technol. 2021, 12, 1649–1672. [Google Scholar] [CrossRef]
  69. Rastogi, S.; Kumari, V.; Sharma, V.; Ahmad, F.J. Gold Nanoparticle-based Sensors in Food Safety Applications. Food Anal. Methods 2021, 15, 468–484. [Google Scholar] [CrossRef]
  70. Prajapati, S.; Padhan, B.; Amulyasai, B.; Sarkar, A. Nanotechnology-based sensors. Biopolym.-Based Formul. 2020, 1, 237–262. [Google Scholar] [CrossRef]
  71. Bashir, O.; Bhat, S.A.; Basharat, A.; Qamar, M.; Qamar, S.A.; Bilal, M.; Iqbal, H.M. Nano-engineered materials for sensing food pollutants: Technological advancements and safety issues. Chemosphere 2022, 292, 133320. [Google Scholar] [CrossRef]
  72. Inan, H.; Poyraz, M.; Inci, F.; Lifson, M.A.; Baday, M.; Cunningham, B.T.; Demirci, U. Photonic crystals: Emerging biosensors and their promise for point-of-care applications. Chem. Soc. Rev. 2017, 46, 366–388. [Google Scholar] [CrossRef] [PubMed]
  73. Jayanthi, V.S.A.; Das, A.B.; Saxena, U. Recent advances in biosensor development for the detection of cancer biomarkers. Biosens. Bioelectron. 2017, 91, 15–23. [Google Scholar] [CrossRef] [PubMed]
  74. Chen, Y.; Liu, J.; Yang, Z.; Wilkinson, J.S.; Zhou, X. Optical biosensors based on refractometric sensing schemes: A review. Biosens. Bioelectron. 2019, 144, 111693. [Google Scholar] [CrossRef] [PubMed]
  75. Ahmad, R.; Wolfbeis, O.S.; Hahn, Y.B.; Alshareef, H.N.; Torsi, L.; Salama, K.N. Deposition of nanomaterials: A crucial step in biosensor fabrication. Mater. Today Commun. 2018, 17, 289–321. [Google Scholar] [CrossRef]
  76. Kaçar, C.; Erden, P.E. An amperometric biosensor based on poly (l-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase–modified glassy carbon electrode for the determination of l-ascorbic acid. Anal. Bioanal. Chem. 2020, 412, 5315–5327. [Google Scholar] [CrossRef]
  77. Erna, K.H.; Felicia, W.X.L.; Rovina, K.; Vonnie, J.M.; Huda, N. Development of curcumin/rice starch films for sensitive detection of hypoxanthine in chicken and fish meat. Carbohydr. Polym. 2022, 3, 100189. [Google Scholar] [CrossRef]
  78. Nur Topkaya, S.; Cetin, A.E. Electrochemical aptasensors for biological and chemical analyte detection. Electroanalysis 2021, 33, 277–291. [Google Scholar] [CrossRef]
  79. Gulaboski, R.; Mirceski, V.; Lovric, M. Square-wave protein-film voltammetry: New insights in the enzymatic electrode processes coupled with chemical reactions. J. Solid State Electrochem. 2019, 23, 2493–2506. [Google Scholar] [CrossRef]
  80. Schockman, K.M.; Byrne, R.H. A hybrid conductometric/spectrophotometric method for determining ionic strength of dilute aqueous solutions. Anal. Chim. Acta 2022, 1220, 340008. [Google Scholar] [CrossRef]
  81. Bais, R. An Overview of the Synergy of Electrochemistry and Nanotechnology for Advancements in Sensing Applications. In Frontiers in Voltammetry; IntechOpen: Rijeka, Croatia, 2022; Volume 1. [Google Scholar] [CrossRef]
  82. Nguyen, H.H.; Lee, S.H.; Lee, U.J.; Fermin, C.D.; Kim, M. Immobilized enzymes in biosensor applications. Materials 2019, 12, 121. [Google Scholar] [CrossRef]
  83. Wang, Z.; Ma, B.; Shen, C.; Lai, O.M.; Tan, C.P.; Cheong, L.Z. Electrochemical biosensing of chilled seafood freshness by xanthine oxidase immobilized on copper-based metal–organic framework nanofiber film. Food Anal. Methods 2019, 12, 1715–1724. [Google Scholar] [CrossRef]
  84. Joon, A.; Ahlawat, J.; Aggarwal, V.; Jaiwal, R.; Pundir, C.S. An improved amperometric determination of xanthine with xanthine oxidase nanoparticles for testing of fish meat freshness. Sens. Bio-Sens. Res. 2021, 33, 100437. [Google Scholar] [CrossRef]
  85. Erol, E.; Yildirim, E.; Cete, S. Construction of biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole-paratoluenesulfonate film. J. Solid State Electrochem. 2020, 24, 1695–1707. [Google Scholar] [CrossRef]
  86. Sharma, N.K.; Kaushal, A.; Thakur, S.; Thakur, N.; Kumar, D.; Bhalla, T.C. Nanohybrid electrochemical enzyme sensor for xanthine determination in fish samples. Biotech 2021, 11, 212. [Google Scholar] [CrossRef]
  87. Sahyar, B.Y.; Kaplan, M.; Ozsoz, M.; Celik, E.; Otles, S. Electrochemical xanthine detection by enzymatic method based on Ag doped ZnO nanoparticles by using polypyrrole. Bioelectrochemistry 2019, 130, 107327. [Google Scholar] [CrossRef]
  88. Boluda, A.; Casado, C.M.; Alonso, B.; García Armada, M.P. Efficient Oxidase Biosensors Based on Bioelectrocatalytic Surfaces of Electrodeposited Ferrocenyl Polycyclosiloxanes—Pt Nanoparticles. Chemosensors 2021, 9, 81. [Google Scholar] [CrossRef]
  89. Furuhashi, M. New insights into purine metabolism in metabolic diseases: Role of xanthine oxidoreductase activity. Am. J. Physiol. Endocrinol. Metab. 2020, 319, E827–E834. [Google Scholar] [CrossRef]
  90. Ahmad, M.W.; Dey, B.; Sarkhel, G.; Yang, D.J.; Choudhury, A. Sea-urchin-like Cobalt-MOF on Electrospun Carbon Nanofiber Mat as a Self-Supporting Electrode for Sensing of Xanthine and Uric Acid. J. Electroanal. Chem. 2022, 920, 116646. [Google Scholar] [CrossRef]
  91. Malhotra, D.; Tran, P.K.L.; Tran, D.T.; Kim, N.H.; Lee, J.H. Cobalt-doped cerium oxide nanocrystals shelled 1D SnO2 structures for highly sensitive and selective xanthine detection in biofluids. J. Colloid Interface Sci. 2021, 600, 299–309. [Google Scholar] [CrossRef]
  92. Norrrahim, M.N.F.; Knight, V.F.; Nurazzi, N.M.; Jenol, M.A.; Misenan, M.S.M.; Janudin, N.; Kasim, N.A.M.; Shukor, M.F.A.; Ilyas, R.A.; Asyraf, M.R.M.; et al. The Frontiers of Functionalized Nanocellulose-Based Composites and Their Application as Chemical Sensors. Polymers 2022, 14, 4461. [Google Scholar] [CrossRef]
  93. Fenton, A.M., Jr.; Brushett, F.R. Using voltammetry augmented with physics-based modeling and Bayesian hypothesis testing to identify analytes in electrolyte solutions. J. Electroanal. Chem. 2022, 904, 115751. [Google Scholar] [CrossRef]
  94. Khan, M.Z.H.; Ahommed, M.S.; Daizy, M. Detection of xanthine in food samples with an electrochemical biosensor based on PEDOT: PSS and functionalized gold nanoparticles. RSC Adv. 2020, 10, 36147–36154. [Google Scholar] [CrossRef] [PubMed]
  95. Ghanbari, K.; Nejabati, F. Ternary nanocomposite-based reduced graphene oxide/chitosan/Cr2O3 for the simultaneous determination of dopamine, uric acid, xanthine, and hypoxanthine in fish meat. Anal. Methods 2020, 12, 1650–1661. [Google Scholar] [CrossRef]
  96. Yazdanparast, S.; Benvidi, A.; Abbasi, S.; Rezaeinasab, M. Enzyme-based ultrasensitive electrochemical biosensor using poly (l-aspartic acid)/MWCNT bio-nanocomposite for xanthine detection: A meat freshness marker. Microchem. J. 2019, 149, 104000. [Google Scholar] [CrossRef]
  97. Wang, D.; Wang, J. A sensitive and label-free electrochemical microRNA biosensor based on Polyamidoamine Dendrimer functionalized Polypyrrole nanowires hybrid. Microchim. Acta 2021, 188, 173. [Google Scholar] [CrossRef] [PubMed]
  98. Sari, S.R.; Tominaga, M. Progress and current trends in the electrochemical determination of phosphate ions for environmental and biological monitoring applications. Anal. Sci. 2022. [Google Scholar] [CrossRef]
  99. Shen, H.; Liu, H.; Wang, X. Surface construction of catalase-immobilized Au/PEDOT nanocomposite on phase-change microcapsules for enhancing electrochemical biosensing detection of hydrogen peroxide. Appl. Surf. Sci. 2023, 612, 155816. [Google Scholar] [CrossRef]
  100. Purohit, B.; Vernekar, P.R.; Shetti, N.P.; Chandra, P. Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis. Sens. Int. 2020, 1, 100040. [Google Scholar] [CrossRef]
  101. Vishnu, N.; Gandhi, M.; Rajagopal, D.; Kumar, A.S. Pencil graphite as an elegant electrochemical sensor for separation-free and simultaneous sensing of hypoxanthine, xanthine and uric acid in fish samples. Anal. Methods 2017, 9, 2265–2274. [Google Scholar] [CrossRef]
  102. Zhang, Y.; Bo, X.; Nsabimana, A.; Han, C.; Li, M.; Guo, L. Electrocatalytically active cobalt-based metal–organic framework with incorporated macroporous carbon composite for electrochemical applications. J. Mater. Chem. A 2015, 3, 732–738. [Google Scholar] [CrossRef]
  103. Bilal, S.; Hassan, M.M.; ur Rehman, M.F.; Nasir, M.; Sami, A.J.; Hayat, A. An insect acetylcholinesterase biosensor utilizing WO3/g-C3N4 nanocomposite modified pencil graphite electrode for phosmet detection in stored grains. Food Chem. 2021, 346, 128894. [Google Scholar] [CrossRef] [PubMed]
  104. Idris, A.; Saleh, T.; Muraza, O.; Sanhoob, M.; Aziz, M.; Al-Betar, A.R. Synthesis of phosphate-modified zeolite as a modifier in carbon paste electrode for nitrite electrochemical detection. J. Mater. Sci. Mater. Electron. 2019, 30, 3283–3293. [Google Scholar] [CrossRef]
  105. Mahale, R.S.; Vasanth, S.; Krishna, H.; Shashanka, R.; Sharath, P.C.; Sreekanth, N.V. Electrochemical sensor applications of nanoparticle modified carbon paste electrodes to detect various neurotransmitters: A review. Appl. Mech. Mater. 2022, 908, 69–88. [Google Scholar] [CrossRef]
  106. Saeed, R.; Feng, H.; Wang, X.; Xiaoshuan, Z.; Zetian, F. Fish quality evaluation by sensor and machine learning: A mechanistic review. Food Control 2022, 137, 108902. [Google Scholar] [CrossRef]
  107. Cao, Q.; Lucktong, J.; Shao, Z.; Chang, Y.; Venton, B.J. Electrochemical treatment in KOH renews and activates carbon fiber microelectrode surfaces. Anal. Bioanal. Chem. 2021, 413, 6737–6746. [Google Scholar] [CrossRef] [PubMed]
  108. Elbadawi, M.; Ong, J.J.; Pollard, T.D.; Gaisford, S.; Basit, A.W. Additive manufacturable materials for electrochemical biosensor electrodes. Adv. Funct. Mater. 2021, 31, 2006407. [Google Scholar] [CrossRef]
  109. Kim, J.; Lee, Y.; Kang, M.; Hu, L.; Zhao, S.; Ahn, J.H. 2D Materials for Skin-Mountable Electronic Devices. Adv. Mater. 2021, 33, 2005858. [Google Scholar] [CrossRef]
  110. Wang, G.; Liu, J.; Yue, F.; Shen, Z.; Xu, D.; Fang, H.; Sun, X. Dual enzyme electrochemiluminescence sensor based on in situ synthesis of ZIF-67@ AgNPs for the detection of IMP in fresh meat. LWT 2022, 165, 113658. [Google Scholar] [CrossRef]
  111. Mazlumoglu, H.; Yilmaz, M. Silver nanoparticle-decorated titanium dioxide nanowire systems via bioinspired poly (l-DOPA) thin film as a surface-enhanced Raman spectroscopy (SERS) platform, and photocatalyst. Phys. Chem. Chem. Phys. 2021, 23, 13396–13404. [Google Scholar] [CrossRef]
  112. Ibrahim, N.; Jamaluddin, N.D.; Tan, L.L.; Mohd Yusof, N.Y. A Review on the Development of Gold and Silver Nanoparticles-Based Biosensor as a Detection Strategy of Emerging and Pathogenic RNA Virus. Sensors 2021, 21, 5114. [Google Scholar] [CrossRef]
  113. Gu, X.; Wang, K.; Qiu, J.; Wang, Y.; Tian, S.; He, Z.; Zong, R.; Kraatz, H.-B. Enhanced electrochemical and SERS signals by self-assembled gold microelectrode arrays: A dual readout platform for multiplex immumoassay of tumor biomarkers. Sens. Actuators B Chem. 2021, 334, 129674. [Google Scholar] [CrossRef]
  114. Zhang, L.T.; Zhou, Y.; Han, S.T. The role of metal–organic frameworks in electronic sensors. Angew. Chem. 2021, 133, 15320–15340. [Google Scholar] [CrossRef]
  115. Dong, J.; Zhao, D.; Lu, Y.; Sun, W.Y. Photoluminescent metal–organic frameworks and their application for sensing biomolecules. J. Mater. Chem. 2019, 7, 22744–22767. [Google Scholar] [CrossRef]
  116. Khorsandi, D.; Zarepour, A.; Rezazadeh, I.; Ghomi, M.; Ghanbari, R.; Zarrabi, A.; Esfahani, F.T.; Mojahed, N.; Baghayeri, M.; Zare, E.N.; et al. Ionic liquid-based materials for electrochemical biosensing. Clin. Transl. Sci. 2022, 2, e127. [Google Scholar] [CrossRef]
  117. Zhang, L.; Li, S.; Xin, J.; Ma, H.; Pang, H.; Tan, L.; Wang, X. A non-enzymatic voltammetric xanthine sensor based on the use of platinum nanoparticles loaded with a metal-organic framework of type MIL-101 (Cr). Application to simultaneous detection of dopamine, uric acid, xanthine and hypoxanthine. Mikrochim. Acta 2019, 186, 9. [Google Scholar] [CrossRef]
  118. Singh, P. Surface plasmon resonance: A boon for viral diagnostics. Ref. Modul. Life Sci. 2017, 2, 1–16. [Google Scholar] [CrossRef]
  119. Malhotra, B.D.; Ali, M.A. Nanomaterials in biosensors: Fundamentals and applications. Nanomater. Biosens. 2018, 1, 1–74. [Google Scholar]
  120. Damborský, P.; Švitel, J.; Katrlík, J. Optical biosensors. Essays Biochem. 2016, 60, 91–100. [Google Scholar] [CrossRef]
  121. Chen, J.; Lu, Y.; Yan, F.; Wu, Y.; Huang, D.; Weng, Z. A fluorescent biosensor based on catalytic activity of platinum nanoparticles for freshness evaluation of aquatic products. Food Chem. 2020, 310, 125922. [Google Scholar] [CrossRef]
  122. Ong, J.J.; Pollard, T.D.; Goyanes, A.; Gaisford, S.; Elbadawi, M.; Basit, A.W. Optical biosensors-Illuminating the path to personalized drug dosing. Biosens. Bioelectron. 2021, 188, 113331. [Google Scholar] [CrossRef]
  123. Hu, S.; Yan, J.; Huang, X.; Guo, L.; Lin, Z.; Luo, F.; Chen, G. A sensing platform for hypoxanthine detection based on amino-functionalized metal organic framework nanosheet with peroxidase mimic and fluorescence properties. Sens. Actuators B Chem. 2018, 267, 312–319. [Google Scholar] [CrossRef]
  124. Liu, Z.; Zhong, Y.; Hu, Y.; Yuan, L.; Luo, R.; Chen, D.; Li, Y. Fluorescence strategy for sensitive detection of adenosine triphosphate in terms of evaluating meat freshness. Food Chem. 2019, 270, 573–578. [Google Scholar] [CrossRef] [PubMed]
  125. Zhao, Z.X.; Guo, Y.P.; Wei, J.; Chen, Q.S.; Chen, X.M. Fluorescent copper nanoclusters for highly sensitive monitoring of hypoxanthine in fish. J. Anal. Test. 2021, 5, 76–83. [Google Scholar] [CrossRef]
  126. Xue, G.; Yu, W.; Yutong, L.; Qiang, Z.; Xiuying, L.; Yiwei, T.; Jianrong, L. Construction of a novel xanthine biosensor using zinc oxide (ZnO) and the biotemplate method for detection of fish freshness. Anal. Methods 2019, 11, 1021–1026. [Google Scholar] [CrossRef]
  127. Luo, Q.; Zhang, Y.; Zhou, Y.; Liu, S.G.; Gao, W.; Shi, X. Portable functional hydrogels based on silver metallization for visual monitoring of fish freshness. Food Control 2021, 123, 107824. [Google Scholar] [CrossRef]
  128. Rayappa, M.K.; Viswanathan, P.A.; Rattu, G.; Krishna, P.M. Nanomaterials enabled and bio/chemical analytical sensors for acrylamide detection in thermally processed foods: Advances and outlook. J. Agric. Food Chem. 2021, 69, 4578–4603. [Google Scholar] [CrossRef]
  129. Hsu, H.C.; Liao, P.W.; Lee, H.T.; Liu, W.C.; Ho, M.L. Silver Nanoplates for Colorimetric Determination of Xanthine in Human Plasma and in Fish Meat via Etching/Aggregation/Fusion Steps. Sensors 2020, 20, 5739. [Google Scholar] [CrossRef]
  130. Mooltongchun, M.; Teepoo, S. A simple and cost-effective microfluidic paper-based biosensor analytical device and its application for hypoxanthine detection in meat samples. Food Anal. Methods 2019, 12, 2690–2698. [Google Scholar] [CrossRef]
  131. Wang, X.; Lin, Z.Z.; Hong, C.Y.; Huang, Z.Y. Colorimetric detection of hypoxanthine in aquatic products based on the enzyme mimic of cobalt-doped carbon nitride. New J. Chem. 2021, 45, 18307–18314. [Google Scholar] [CrossRef]
  132. Mustafa, F.; Andreescu, S. Based enzyme biosensor for one-step detection of hypoxanthine in fresh and degraded fish. ACS Sens. 2020, 5, 4092–4100. [Google Scholar] [CrossRef]
  133. Mustafa, F.; Othman, A.; Andreescu, S. Cerium oxide-based hypoxanthine biosensor for Fish spoilage monitoring. Sens. Actuators B Chem. 2021, 332, 129435. [Google Scholar] [CrossRef]
  134. Ding, N.; Dong, S.; Zhang, Y.; Lu, D.; Lin, J.; Zhao, Q.; Shi, X. Portable silver-doped prussian blue nanoparticle hydrogels for colorimetric and photothermal monitoring of shrimp and fish freshness. Sens. Actuators B Chem. 2022, 363, 131811. [Google Scholar] [CrossRef]
  135. Chen, Z.; Lin, Y.; Ma, X.; Guo, L.; Qiu, B.; Chen, G.; Lin, Z. Multicolor biosensor for fish freshness assessment with the naked eye. Sens. Actuators B Chem. 2017, 252, 201–208. [Google Scholar] [CrossRef]
  136. Fanali, S.; Chankvetadze, B. Some thoughts about enantioseparations in capillary electrophoresis. Electrophoresis 2019, 40, 2420–2437. [Google Scholar] [CrossRef] [PubMed]
  137. Kubáň, P.; Foret, F.; Erny, G. Open source capillary electrophoresis. Electrophoresis 2019, 40, 65–78. [Google Scholar] [CrossRef]
  138. Lemasson, E.; Richer, Y.; Bertin, S.; Hennig, P.; West, C. Characterization of retention mechanisms in mixed-mode HPLC with a bimodal reversed-phase/cation-exchange stationary phase. Chromatographia 2018, 81, 387–399. [Google Scholar] [CrossRef]
  139. Garg, D.; Singh, M.; Verma, N. Review on recent advances in fabrication of enzymatic and chemical sensors for hypoxanthine. Food Chem. 2021, 375, 131839. [Google Scholar] [CrossRef]
  140. Cho, I.H.; Kim, D.H.; Park, S. Electrochemical biosensors: Perspective on functional nanomaterials for on-site analysis. Biomater. Res. 2020, 24, 6. [Google Scholar] [CrossRef]
  141. Manikandan, V.S.; Adhikari, B.; Chen, A. Nanomaterial based electrochemical sensors for the safety and quality control of food and beverages. Analyst 2018, 143, 4537–4554. [Google Scholar] [CrossRef]
Figure 1. The available methods of biosensors for the detection of purine derivatives.
Figure 1. The available methods of biosensors for the detection of purine derivatives.
Biosensors 13 00217 g001
Figure 2. The catabolism of ATP with the respective enzymes responsible for the oxidation of each compound.
Figure 2. The catabolism of ATP with the respective enzymes responsible for the oxidation of each compound.
Biosensors 13 00217 g002
Table 1. Conventional methods for detecting purine and their analytical performance in food applications.
Table 1. Conventional methods for detecting purine and their analytical performance in food applications.
Analysis MethodSampleAnalyteLinear RangeLODReference
HPLC-DADCow milkAllantoin,
Uric acid,
Xa,
Hx
3.125–100 µg/mL0.74 µg/mL
0.16 µg/mL
0.09 µg/mL
0.14 µg/mL
[16]
HPLC-UVFish, shellfish,
clam
Adenine,
Guanine,
Hx,
Xa
0.05–300 mg/L0.02 mg/L
0.03 mg/L
0.06 mg/L
0.10 mg/L
[45]
CZESalted herring meatTrp,
Thr,
Met,
Phe,
Tyr
--[46]
UHPLC-MSChickenHistidine,
Hx,
Inosine
--[47]
UHPLC-MSSerumTwenty-three purine derivatives0.002–11.2 μg/mL0.05–6.3 ng/mL[48]
GCMSBeefGlutamine,
Adenosine,
Hx
--[49]
UPLC-MSFresh tuna fishUracil,
Inosine,
Hx
--[50]
SpectrophotometricCattle meatAdenosine,
Inosine,
Hx
--[51]
HPLC-UVUmami soup stockInosine monophosphate, Guanosine monophosphate,
Hypoxanthine,
Inosine
--[53]
Reverse phase HPLCProcessed chicken meatAdenine,
Guanine,
Hx,
Xa
--[54]
HPLC-VWDChinese chicken brothAdenine,
Guanine,
Hx,
Xa,
Uric acid
0.05–100 mg/L0.66 µg/L
0.64 µg/L
0.58 µg/L
1.14 µg/L
1.71 µg/L
[55]
HPLC-UVShiitake mushroomGuanine,
Adenine,
Hx,
Xa
--[56]
CZEYeast (Saccharomyces cerevisiae)Adenine1–20 mg/L1.11 μg/L[57]
CZE-UVBeerHx,
Xa,
Adenine,
Thymine
0.4–40 mg/L0.1 mg/L
0.1 mg/L
0.1 mg/L
0.3 mg/L
[58]
CE-UVSoybean milkAdenine,
Guanine,
Xa,
Hx
0.5 to 100 mg/mL0.08 μg/mL
0.06 μg/mL
0.09 μg/mL
0.05 μg/mL
[59]
Table 4. Comparison of the analytical performance of conventional techniques and nanotechnology-based biosensors.
Table 4. Comparison of the analytical performance of conventional techniques and nanotechnology-based biosensors.
Analysis MethodSampleAnalyteLinear RangeLODReference
Conventional
HPLC-DADCow milkAllantoin,
Uric acid,
Xa,
Hx
3.125–100 µg/mL0.74 µg/mL
0.16 µg/mL
0.09 µg/mL
0.14 µg/mL
[16]
Au-PEDOT-fMWCNT/GCEFish meatUA
Xa
Hx
0.1–800 μM
0.05–175 μM
0.1–150 μM
199.3 nM
24.1 nM
90.5 nM
[20]
HPLC-UVMarine fishAdenine,
Guanine,
Hx,
Xa
0.1–300 mg/L0.0774 mg/L
0.0178 mg/L
0.0118 mg/L
0.0555 mg/L
[40]
HPLC-UVRaw anchoviesAdenine,
Guanine,
Hx,
Xa
--[44]
HPLC-UVFish, shellfish,
clam
Adenine,
Guanine,
Hx,
Xa
0.05–300 mg/L0.02 mg/L
0.03 mg/L
0.06 mg/L
0.10 mg/L
[45]
UHPLC-MSSerum23 of purine derivatives0.002–11.2 μg/mL0.05–6.3 ng/mL[48]
HPLC-VWDChinese chicken brothAdenine,
Guanine,
Hx,
Xa,
Uric acid
0.05–100 mg/L0.66 µg/L
0.64 µg/L
0.58 µg/L
1.14 µg/L
1.71 µg/L
[59]
Nanotechnology based biosensor
Amperometry (XODNPs/Au)Fish meatXa0.01–1.0 μM0.01 μM[84]
XO/Poly(l-Asp)/MWCNT/GCE electrodeFish meatXa0.001–0.004 μM3.5 × 10−4 μM[96]
Fluorescent-NH2-Cu-MOF nanosheetFishHx10–2000 μM3.93 μM[123]
CeNPs/XOD/silanized paperDegraded fishHx800 μM15 μM[133]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Felicia, W.X.L.; Rovina, K.; ‘Aqilah, N.M.N.; Vonnie, J.M.; Yin, K.W.; Huda, N. Assessing Meat Freshness via Nanotechnology Biosensors: Is the World Prepared for Lightning-Fast Pace Methods? Biosensors 2023, 13, 217. https://doi.org/10.3390/bios13020217

AMA Style

Felicia WXL, Rovina K, ‘Aqilah NMN, Vonnie JM, Yin KW, Huda N. Assessing Meat Freshness via Nanotechnology Biosensors: Is the World Prepared for Lightning-Fast Pace Methods? Biosensors. 2023; 13(2):217. https://doi.org/10.3390/bios13020217

Chicago/Turabian Style

Felicia, Wen Xia Ling, Kobun Rovina, Nasir Md Nur ‘Aqilah, Joseph Merillyn Vonnie, Koh Wee Yin, and Nurul Huda. 2023. "Assessing Meat Freshness via Nanotechnology Biosensors: Is the World Prepared for Lightning-Fast Pace Methods?" Biosensors 13, no. 2: 217. https://doi.org/10.3390/bios13020217

APA Style

Felicia, W. X. L., Rovina, K., ‘Aqilah, N. M. N., Vonnie, J. M., Yin, K. W., & Huda, N. (2023). Assessing Meat Freshness via Nanotechnology Biosensors: Is the World Prepared for Lightning-Fast Pace Methods? Biosensors, 13(2), 217. https://doi.org/10.3390/bios13020217

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop