Next Article in Journal
Elastic Electron Scattering from Be, Mg, and Ca
Previous Article in Journal
Time-Dependent Density Functional Theory for Atomic Collisions: A Progress Report
Previous Article in Special Issue
Nanoparticle Interferometer by Throw and Catch
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Sensitivity of a Point-Source-Interferometry-Based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms

1
Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA
2
Digital Optics Technologies, Rolling Meadows, IL 60008, USA
3
Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL 60208, USA
*
Author to whom correspondence should be addressed.
Atoms 2024, 12(6), 32; https://doi.org/10.3390/atoms12060032
Submission received: 25 April 2024 / Revised: 31 May 2024 / Accepted: 5 June 2024 / Published: 11 June 2024
(This article belongs to the Special Issue Advances in and Prospects for Matter Wave Interferometry)

Abstract

:
We analyze theoretically the sensitivity of accelerometry and rotation sensing with a point source interferometer employing large momentum transfer (LMT) and present a design of an inertial measurement unit (IMU) that can measure rotation around and acceleration along each of the three axes. In this design, the launching technique is used to realize the LMT process without the need to physically change directions of the Raman pulses, thus significantly simplifying the apparatus. We also describe an explicit scheme for such an IMU.

1. Introduction

For inertial navigation, it is necessary to measure both acceleration and rotation. Multi-axis atom interferometers with such capabilities are being actively investigated [1,2,3,4,5,6]. One challenge for a conventional atom interferometer is distinguishing between phase shifts produced by acceleration and rotation. The techniques used for this purpose include operating two or more interferometers where atoms move in opposite directions [1,2] and using a four-pulse interferometer protocol [1,3]. The counter-propagating technique [1,2] involves arguably an increased level of complexity, which may pose challenges for applications requiring portability. In the case of the four-pulse technique [1,3], the phase shift is proportional to the cross product of acceleration and angular velocity. Thus, in order to determine one of these measurands, the other must be accurately known. For measuring rotation on an Earth-bound platform, the acceleration due to gravity can be used as such a known parameter. However, for a space-borne platform, there does not exist such a known parameter. Although an offset acceleration or rotation could be applied to work as such a parameter, uncertainties in the applied offsets would limit the accuracy of such a device significantly.
Arguably, a more suitable method for distinguishing acceleration- and rotation-induced phase shifts is the point source interferometer (PSI) [7,8,9,10,11]. A one-axis PSI can be used for measuring acceleration along the primary axis and two components of rotation along the axes orthogonal to the primary axis. In a conventional atomic interferometer, the signal is determined by measuring the total population of the atoms in a particular internal quantum state, and there exists a well-developed method for the sensitivity limit analysis for such a detection scheme [12,13]. However, for a PSI, the information about the acceleration and the rate of rotation is distributed spatially over the whole atomic cloud. Specifically, the magnitude of rotation is inferred from the spacing of the spatial fringes formed by the atoms in one of two internal quantum states, and the direction of rotation can be gleaned from the orientations thereof. The acceleration, on the other hand, shifts the phase of the fringes. As such, an analysis of the sensitivity of rotation sensing and accelerometry for a PSI is very different from that of a conventional atomic interferometer. To the best of our knowledge, there are only sensitivity analyses for rotation sensing, and they are heuristic [14,15]. In this paper, we present a systematic and rigorous analysis of both acceleration and rotation sensitivity of a PSI. We present a generalized expression for these sensitivities in terms of the signals measured by each pixel of a camera used for monitoring the distributed signal. We find that when the acceleration or rotation exceeds certain levels, it is possible to express the sensitivity in a closed form. Otherwise, the sensitivity can only be determined via a numerical evaluation of the general expression.
In order to determine the ultimate capability of a PSI, we also consider the case when Raman-transition-based large momentum transfer (LMT) [14,16,17,18] is incorporated in order to enhance the sensitivity for both rotation sensing and accelerometry. The way to implement LMT is to apply additional Raman π pulses in opposite effective directions. The effective propagating direction of a pair of counter-propagating Raman beams is defined as the propagating direction of the higher-frequency Raman beam. Some of the additional π pulses are effectively parallel to the original three Raman pulses and the rest are effectively antiparallel. One method for flipping the directions of the two Raman beams is to swap the polarizations of the two beams before a polarizing beam splitter (PBS) [17,18]. To change the polarizations of the two beams rapidly without wasting optical power, a Pockels cell can be used [17]. A Pockels cell with a high extinction ratio needs to be driven by a voltage as high as several kilovolts. Furthermore, in this scheme, the two Raman beams must have orthogonal polarizations and thus cannot be two components in the output from an electro-optic modulator (EOM). This method for swapping the polarizations can increase the complexity of the system considerably. Another way to flip the directions of the Raman beams is to make use of the opposite Doppler shifts for Raman beam pairs with opposite effective directions [19]. The advantage of this method is that no external device is needed to swap the directions of the Raman beams. To induce a large Doppler shift for the Raman beam, a high offset velocity of the atoms is required. Usually, this offset velocity is induced by gravity. However, the free-fall approach has three drawbacks. First, this approach can only impart an offset velocity in the vertical direction. Second, it takes a long time to accumulate a high offset velocity. Third, the atoms thermally expand during the free-fall process. In this paper, we propose to use moving-molasses-induced launching of atoms to impart such an offset velocity for LMT.
The use of the launching technique for breaking the degeneracy between the transitions driven by the two pairs of Raman beams has been demonstrated previously [11]. What would be important is to show that this approach can be generalized in three dimensions with a single apparatus, in the context of implementing high-order LMT, since the ability to reverse the effective direction of the Raman beams via changing the modulation frequency would simplify the operation of the system. The advantage resulting from this simplification of the LMT process would become more important for an inertial measurement unit (IMU) for measuring rotation around and acceleration along each of the three axes, since it would require the operation of three PSIs, either in parallel or serially. However, it is not a priori obvious how such a scheme can be generalized for three-axis operation in a manner that would not introduce other potential complications. As such, we present an explicit scheme, based on the use of 87Rb atoms, for implementing an IMU based on such a PSI, incorporating the LMT process as well as launching of atoms.
The rest of the paper is organized as follows. In Section 2, we present an analysis of the sensitivity of rotation sensing and accelerometry based on a signal image of a PSI. In Section 3, we analyze the effects of various experimental imperfections for the IMU. In Section 4, we present the general modality for an IMU employing point source interferometry. In Section 5, we describe how the process of LMT is incorporated into the IMU. In Section 6, we present an explicit description for such an IMU, employing 87Rb atoms. Concluding discussions are presented in Section 7. The appendix shows the expression for phase shifts due to acceleration and rotation as functions of the order of LMT used.

2. Analysis of Acceleration and Rotation Sensitivity Based on a Signal Image of a PSI

To start with, we recall briefly how a conventional PSI operates on a terrestrial platform works. First, atoms are captured in a magneto-optic trap (MOT) and then undergo optical molasses cooling. Then, optical pumping and state selection is applied to place the atoms in the m F = 0 Zeeman substate. Next, an offset magnetic field is turned on, and the atoms are allowed to fall freely for some time to gain a mean offset velocity so that different Raman resonant peaks resulting from a retroreflecting configuration can be separated. This step is followed by the application of Raman pulses in the vertical direction to induce atomic interference. Finally, an imaging beam is used to map the spatial distribution of atoms in one internal quantum state. This signal is then analyzed to infer the rates of rotation around the axes orthogonal to the vertical direction. It is also possible to infer the acceleration experienced along the vertical direction by analyzing the shift in the fringe pattern.
We next consider a PSI augmented with LMT. In Figure 1, we describe schematically the basic approach for LMT for a PSI [14,16,17,18]. Recalling briefly, the LMT scheme works as follows. The conventional sequence of three counter-propagating Raman pulses (denoted as A 0 , B 0 , and C 0 ) are augmented by additional counter-propagating π pulses. For an LMT of order n , the process requires the application of 4 n additional π pulses. In Figure 1, we have illustrated the case for n = 2 . In this case, the first additional π pulse ( A 1 ) propagates in an effective direction opposite to that of the initial π / 2 pulse ( A 0 ). For the next π pulse ( A 2 ), the effective direction is opposite to the previous π pulse ( A 1 ). The effective directions of the rest of the additional π pulses are also shown in Figure 1. It can also be seen that the pulse sequence is symmetric about pulse B 0 . The pulse sequence for an arbitrary order of LMT can be obtained by generalizing this pattern. As shown in Appendix A, the acceleration-induced phase shift of an atom interferometer with LMT can be expressed as ϕ = k eff a T ( T + 2 j = 1 n T j ) and the rotation-induced phase shift as ϕ = ( k eff × Ω ) r ( T + 2 j = 1 n T j ) , where k eff is the effective wavenumber of the counter-propagating Raman beams, whose absolute value is approximately 2 k ; a is the linear acceleration; Ω is the angular velocity; and r is the displacement of the atoms from pulse A 0 to C 0 . The values of the time intervals T and T j are defined in Figure 1.
Using the results shown above, we see that for a system employing n-th order LMT, the ideal population distribution shown in the image should be
P ( r ) = 1 2 [ 1 + cos ( k Ω r + ϕ a ) ] f ( r )
where k Ω = k eff × Ω T ( T + 2 j = 1 n T j ) , ϕ a = k eff a T ( T + 2 j = 1 n T j ) , and f ( r ) is the profile of the final atomic cloud. It is easier to extract the angular velocity Ω and the acceleration a in the Fourier domain. The Fourier transform of this image is
P ˜ ( k ) = 1 2 f ˜ ( k ) + 1 4 e i ϕ a f ˜ ( k k Ω ) + 1 4 e i ϕ a f ˜ ( k + k Ω )
where k is the conjugate variable of r , and f ˜ ( k ) is the two-dimensional Fourier transform of f ( r ) . There are three peaks in the Fourier domain. The two side peaks are located at ± k Ω , and the phases of the two side peaks are ± ϕ a . Accordingly, the positions of the side peaks can be used to infer Ω , and the phases of the side peaks can be used to infer a . From the expression of k Ω and ϕ a , it can be seen that only the component of Ω perpendicular to k eff and the component of a parallel to k eff can be measured.
Physically, Equation (2) can be understood as the convolution between the Fourier transform of f ( r ) , which is f ˜ ( k ) , and the Fourier transform of a uniformly spaced fringe pattern of infinite spatial extent. This pattern can be decomposed into a DC part, whose FT is a delta function centered at k = 0 , and an AC part, whose Fourier transform is two delta functions at k = ± k Ω , multiplied by the phase factors. As such, the condition for the two peaks in Equation (2) to be clearly separable is that the extent of f ˜ ( k ) must be smaller than k Ω . This condition would be satisfied if the shape of the atomic cloud, f ( r ) , is smooth enough not to have variations on a scale smaller than the fringe spacings.
In a typical atomic sensor, such as an atomic clock, an atomic magnetometer, or a conventional atomic interferometer, the signal corresponds to the total number of atoms in a certain state (referred to as the detected state in what follows). In contrast, the signal of a PSI consists of the spatial distribution of the detected-state counts. Therefore, the well-established sensitivity analysis technique for the devices that only measure the total number of detected-state atoms cannot be applied to a PSI. As such, to the best of our knowledge, a systematic analysis of the rotation and acceleration sensitivity of a PSI does not exist in the literature. Refs. [14,15] developed heuristic expressions for the rotation sensitivity of a PSI without any analysis of the acceleration sensitivity.
Here, we derive rigorously the expressions for the uncertainties in the measurement of acceleration and rotation using a PSI for a generic situation that may or may not include augmentation via the LMT process. For specificity, we assume the situation where a camera with an array of pixels with identical sensitivities is used to capture a two-dimensional image of the atoms in the detected state. Without loss of generality, we consider the case where k Ω is in the x direction, and the image is taken in the x-y plane. In this case, it is not necessary to consider the 2D distribution of the signal. Instead, we first integrate the 2D image along the y direction, thus producing an effective 1D signal along the x direction. We note first that each atom can be either in or out of the detected state, so that the detection process is binary. As such, in a pixel labeled as l in this 1D image, the number of detected-state atoms, p l , follows a binomial distribution:
p l B [ f ( x l ) , 1 2 ( 1 + c cos ϕ ) ]
where f ( x l ) is the atom count in pixel l, x l is the x coordinate of pixel l, c is the contrast of the interference fringes, ϕ = k Ω x l + ϕ a , and B ( n , p ) denotes the binomial distribution, with n being the number of trials and p being the probability of yielding a successful result in each trial. Therefore, it is easy to show that [20]
p l = 1 + c cos ϕ 2 f ( x l ) Δ p l 2 = 1 c 2 cos 2 ϕ 4 f ( x l )
where p i is the expectation value of p i and Δ p i is the standard deviation.
Although it is practically more convenient to analyze the signal in the Fourier domain, as illustrated earlier, a direct derivation of the measurement uncertainties in this domain involves a complicated propagation of uncertainty. Therefore, we consider the uncertainty derivation in the spatial domain directly. Considering that no information is lost in a Fourier transform, the theoretical limit of the uncertainty does not depend on which domain the derivation is implemented in. In this domain, one possible way to extract the values of k Ω and ϕ a is to fit the 1D image with the expected profile of p l via the process of least weighted squares regression. Explicitly, this corresponds to minimizing the value of the expression l = 1 L ( p l p l ) 2 / f ( x l ) , where L is the number of pixels, by adjusting the parameters k Ω and ϕ a . Therefore, the derivatives of this expression with respect to k Ω and ϕ a have null value:
l = 1 L p l p l f ( x l ) p l k Ω = 0 l = 1 L p l p l f ( x l ) p l ϕ a = 0
Equation (5) defines k Ω and ϕ a as implicit functions of { p 1 , p 2 , , p L } . According to the rule for uncertainty propagation, the variances of k Ω and ϕ a can be expressed as
Δ k Ω 2 = ( k Ω p 1 ) A 2 Δ p 1 2 + ( k Ω p 2 ) A 2 Δ p 2 2 + + ( k Ω p L ) A 2 Δ p L 2 Δ ϕ a 2 = ( ϕ a p 1 ) A 2 Δ p 1 2 + ( ϕ a p 2 ) A 2 Δ p 2 2 + + ( ϕ a p L ) A 2 Δ p L 2
where the subscript A indicates that the derivative is evaluated at point A , and A stands for the point p 1 = p 1 , p 2 = p 2 , , p L = p L . Therefore, to calculate the variances of k Ω and ϕ a , it is necessary to calculate their derivatives with respect to p 1 , p 2 , , p L . Taking the derivative of Equation (5) with respect to, for example, p 1 , at point A, it is obtained that
l = 1 L ( p 1 p l p l f ( x l ) ) A p l k Ω + l = 1 L ( p l p l f ( x l ) ) p l = p l ( p 1 p l k Ω ) A = l = 1 L ( p 1 p l p l f ( x l ) ) A p l k Ω = 0 l = 1 L ( p 1 p l p l f ( x l ) ) A p l ϕ a + l = 1 L ( p l p l f ( x l ) ) p l = p l ( p 1 p l ϕ a ) A = l = 1 L ( p 1 p l p l f ( x l ) ) A p l ϕ a = 0
which follows that
α ( k Ω p 1 ) A + β ( ϕ a p 1 ) A = 1 f ( x 1 ) p 1 k Ω β ( k Ω p 1 ) A + γ ( ϕ a p 1 ) A = 1 f ( x 1 ) p 1 ϕ a
where
α l = 1 L 1 f ( x l ) ( p l k Ω ) 2 = c 2 4 l = 1 L f ( x l ) x l 2 sin 2 ϕ β l = 1 L 1 f ( x l ) p l k Ω p l ϕ a = c 2 4 l = 1 L f ( x l ) x l sin 2 ϕ γ l = 1 L 1 f ( x l ) ( p l ϕ a ) 2 = c 2 4 l = 1 L f ( x l ) sin 2 ϕ
We now consider first the limit where the number of visible fringes is large enough so that the peaks shown in Equation (2) are separated to the extent that the overlaps between the spectral (spatial–frequency) distributions of the neighboring peaks are negligible. In this case, the coefficients in Equation (9) can be approximated as
α c 2 4 sin 2 ϕ l = 1 L f ( x l ) x l 2 = c 2 N σ f 2 8 β c 2 4 sin 2 ϕ l = 1 L f ( x l ) x l = 0 γ c 2 4 sin 2 ϕ l = 1 L f ( x l ) = c 2 N 8
where N is the number of interrogated atoms in one shot and σ f is the standard deviation of the distribution f ( x ) . Then, Equation (8) can be simplified as
( k Ω p 1 ) A = 8 p 1 / k Ω N c σ f 2 f ( x 1 ) = 4 x 1 sin ϕ N c σ f 2 ( ϕ a p 1 ) A = 8 p 1 / ϕ a N c f ( x 1 ) = 4 sin ϕ N c
Substituting Equation (11) into Equation (6), it can be obtained that
Δ k Ω 2 4 l = 1 L f ( x l ) x l 2 N 2 c 2 σ f 4 sin 2 ϕ ( 1 c 2 cos 2 ϕ ) = 4 c 2 2 N c 2 σ f 2 Δ ϕ a 2 4 l = 1 L f ( x l ) N 2 c 2 sin 2 ϕ ( 1 c 2 cos ϕ ) = 4 c 2 2 N c 2
Therefore, the sensitivity limits can be expressed as:
Δ ϕ a 1 = c 2 N 4 c 2 c N 2 Δ k Ω 1 = c σ f 2 N 4 c 2 c σ f N 2
Substituting the expressions for k Ω and ϕ a , the precision of the acceleration and the angular velocity can be expressed as:
Δ a 1 = k t T 2 c N 2 ;   Δ Ω 1 = k t T c σ f N 2
where k t is the momentum transfer divided by .
When we take into account the number of measurement cycles that are repeated within a certain period of time τ , given by τ / τ 0 , the measurement-time-dependent sensitivities can be expressed as:
Δ a 1 = k t T 2 c N τ 2 τ 0 ;   Δ Ω 1 = k t T c σ f N τ 2 τ 0
where τ 0 is the single-shot duration, including any dead-time between each cycle. For a specific set of parameters, namely k t = 10 k eff , T = 20   ms , c = 0.5 , N = 10 6 , τ 0 = 1   s , and σ f = 1   mm , measurement uncertainties corresponding to these sensitivities are calculated to be Δ Ω τ = 0.88   μ rad s 1 Hz 1 / 2 and Δ a τ = 4.5   nano - g Hz 1 / 2 .
In cases where the spectral (spatial–frequency) distributions of the neighboring peaks shown in Equation (2) still overlap significantly, numerical simulations based on Equations (6), (8), and (9) are needed to find the exact sensitivities because there are no simple analytical expressions for them, keeping in mind that the sensitivities are also proportional to the square root of the repetition number of the measurement cycles. Nevertheless, the analytical results shown here serve as important indicators for estimating the achievable sensitivities. The sensitivity analysis presented above applies to each axis of the three-axis IMU, since it operates in a sequential mode. It should be noted that the expression of rotation sensitivity shown in the right part of Equation (14) agrees with the heuristic expression for the same given in Ref. [14]. However, the analysis presented above applies more broadly to situations where the constraint used in deriving Equation (14) is not valid. Furthermore, it should be noted again that no analysis of acceleration sensitivity, even a heuristic one, was given in Ref. [14].
To show how the sensitivity converges to the expressions shown in Equation (13) as k Ω increases, the accelerometry sensitivity versus k Ω σ f for Gaussian f ( x ) is plotted in Figure 2 for ϕ a = 0 and ϕ a = π / 2 , using numerical simulations based on Equations (6), (8), and (9). It can be seen that when k Ω σ f is close to zero, the sensitivity depends on ϕ a , and that as k Ω σ f increases to π , the sensitivity converges to the expressions shown in Equation (13) regardless of the value of ϕ a .
It should also be noted that measurement of acceleration with any atomic interferometer, including the PSI, becomes ambiguous when the phase shift due to acceleration exceeds the value of 2 π . This is not a problem for a platform for which the acceleration is expected to be small enough so that the phase shift would be much less than 2 π . For platforms that may undergo much larger acceleration, it would be necessary to make use of a coarse-grained auxiliary accelerometer for disambiguation of the signal [21]. In the case of the IMU, three such auxiliary accelerometers would be required.

3. Experimental Imperfections Affecting the PSI Sensitivity

From the analytical results presented above, we see that the parameters that affect the sensitivities are as follows: the fringe contrast ( c ), the order of LMT ( k t ), the duration of the Raman pulse sequence ( 2 T ), the number of atoms interrogated in one shot ( N ), the single-shot duration ( τ 0 ), and the final size of the atomic cloud ( σ f ), which only affects the rotation measurement sensitivity. In practice, the fringe contrast c depends on some other parameters due to various imperfections, which can be divided into two categories. The first category pertains to effects that prevent the transition efficiency of the Raman pulses from reaching unity. These include Doppler-shift-induced detuning, spatial inhomogeneity and temporal fluctuation of the Raman beam intensity, and spontaneous emission. The second category pertains to other imperfections that are unrelated to the Raman pulse transition efficiency. These include a finite initial size of the atomic cloud and the imaging noise. We next consider these two categories in sequence.
An important property of the imperfections in the first category is that they result in a reduction in c as the order of LMT increases. Therefore, generally, there exists an optimal order of LMT that maximizes the sensitivity for a given set of operating parameters. In Ref. [14], we studied optimization of the LMT order when Doppler-shift-induced detuning and spontaneous emission are taken into account. In Figure 12 of Ref. [14], the sensitivity enhancement as a function of the order of LMT is plotted for a set of discrete Raman beam intensities. However, it is also instructive to study how the maximum sensitivity enhancement varies as a function of the Raman beam intensity. We have carried out such a study, based on the analytical result presented in Ref. [14]. Some results in Ref. [14] are summarized as follows. The two-photon Rabi frequency can be expressed as Ω 2 / 2 Δ , where Ω is the single-photon Rabi frequency and Δ is the single-photon detuning, and the effective spontaneous decay rate can be expressed Γ Ω 2 / 4 Δ 2 . Therefore, for a fixed Ω, a larger Δ decreases both the two-photon Rabi frequency and the spontaneous decay rate. As such, there exists an optimal Δ that maximizes the signal contrast, and this optimal Δ depends on Ω . If the optimal detuning is adopted, the optimal order of LMT and the corresponding maximum LMT-induced sensitivity enhancement as a function of the Raman beam intensity are shown in Figure 3. Here, the LMT-induced sensitivity enhancement factor is the ratio of the sensitivity with LMT applied to that without LMT. It should be kept in mind that for each Raman beam intensity, the maximum enhancement factor requires a different number of LMT pulses. These considerations have to be taken into account in the operation of the IMU.
There are some methods to suppress the effect of the large relative Doppler shift between the two interferometer arms when the order of LMT is high. These methods include addressing each arm individually [22], which has been applied to Bragg transitions, and using Floquet pulses [23], which has been applied to single-photon transitions. In principle, these methods can also be applied to Raman transitions. However, detailed theoretical modeling is needed to see how well these techniques would work in this case of Raman transitions and will be carried out by us in the near future.
For the second category, we note first that the effect of the imperfections related to imaging would depend on the experimental details of any particular implementation of the PSI. In contrast, the effect of the finite initial size of the atomic cloud is more fundamental. As such, we consider here the effect of this imperfection in some details. For a PSI where the initial radius of the atomic cloud σ 0 0 , a larger T not only increases the phase shift but also makes the actual sensitivity closer to the ideal one by increasing the ratio σ f / σ 0 , where σ f is the final radius of the atomic cloud. However, a larger T increases the drifting and falling distances of the atoms. There is a trade-off between the effect of σ f / σ 0 and the apparatus size. For convenience, we define the parameter b 1 σ 0 2 / σ f 2 , which is called the fringe broadening factor since the actual wavenumber of the fringes when σ 0 0 is given by k Ω = b k Ω . This factor also reduces the contrast according to the following relation: c = c exp [ k Ω 2 b ( 1 b ) ] [7,8,14]. Therefore, the ratio of the actual sensitivity to the ideal one can be expressed as b exp [ k Ω 2 b ( 1 b ) ] . This ratio is plotted in Figure 4 for σ 0 = 0.2   mm and k Ω = π / 2   cm 1 , when the temperature of the atoms is 6 µK. It can be seen that this ratio can exceed 80% when T = 20   ms . With T = 20   ms (corresponding to an expansion time of 40 ms), and assuming an offset velocity of, for example, 1   m s 1 , the distance traveled by the atoms during this process would be about 4 cm. The offset velocity must induce a relative Doppler shift much higher than the width of the Doppler and power broadening, as well as the Doppler shift corresponding to the momentum transfer. For nth order of LMT, the Doppler shift resulting from the momentum transfer can be estimated as n × 30   kHz .
We finally consider systematic errors, which are characterized by the property that they cannot be corrected by more repetitions of the measurement. Therefore, careful analysis and calibration are needed to alleviate the effect of such errors. Sources of systematic errors encompass a wide range and strongly depend on the specific experimental system, like residual light shift, residual Zeeman shift, and wavefront distortion of the Raman beams. These sources of error are relevant to all light pulse atom interferometers. As such, addressing such sources of error is beyond the scope of this paper. Instead, we address one particular source of error that is particularly relevant to the scheme proposed here. Specifically, we consider the effect of residual Zeeman shift resulting from magnetic field gradient. In most atomic sensors, the effect of magnetic fields and gradients thereof can be suppressed to an arbitrary degree by employing magnetic shielding and avoiding the presence of any strong magnetic field nearby. However, for the particular design of the PSI we have proposed here, the unavoidable use of a Faraday rotator not too far from the atoms implies that the effect of the magnetic field gradient may be more substantial than it is for other atomic sensors. This would be true even if a magnetic shield is employed around the atoms, since one must allow openings in the shield for the optical beams to pass through.
Although only the m F = 0 Zeeman substates are involved in the interference process, they are not completely resistant to external magnetic fields due to higher-order Zeeman shifts. If the atoms move through a spatially varying magnetic field, the energy gap between the two m F = 0 Zeeman substates also vary, which can potentially induce a phase shift. According to the Breit–Rabi formula [24,25], the F = 1 ( 2 ) , m F = 0 Zeeman substate is subject to a second-order Zeeman shift of ± Δ Z = ± ( g S μ B B ) 2 / 4 Δ HFS . Therefore, the relative second-order Zeeman shift between the two m F = 0 Zeeman substates is shown to be 2 Δ Z , where g S 2 is the g-factor of the electron spin, μ B is the Bohr magneton, B is the magnetic field magnitude, and Δ HFS is the hyperfine splitting of the ground state.
To estimate the phase shift caused by this second order Zeeman effect, we consider an example case where an atom is exposed to a magnetic field of 3 G in the first half of the Raman pulse sequence but moves to a region with a magnetic field of 3.01 G in the second half. These values of the magnetic field and the gradient thereof are merely examples based on what might reasonably be expected in the presence of a Faraday rotator in the path of the Raman beams. For a physical implementation of the PSI employing the Faraday rotator, one has to measure the actual magnetic field and the gradient thereof, and scale the results of the analysis presented below accordingly.
For these values of the magnetic field and its gradient, the energy gap between the two m F = 0 Zeeman substates differs by 35 Hz between the first half and the second half of the Raman pulse sequence. For T = 20   ms , the extra phase shift would be about 1.4 π . Another effect of the magnetic field gradient is a force acting on the atoms resulting from the gradient of the second order Zeeman shift. The F = 1 ( 2 ) , m F = 0 Zeeman substate is a high (low) field seeking state. The force can be calculated to be d Δ Z / d z = ( d B / d z ) ( g S 2 μ B 2 B / 2 Δ HFS ) , which is about 1.1 × 10 23   dyn when B = 3   G and d B / d z = 1   G cm 1 . This force causes an acceleration of about 81 micro-g for 87Rb atoms. Therefore, it would be very difficult to measure the absolute acceleration directly from the phase shift. Even for measuring a relative acceleration, strong magnetic shielding may be needed to decrease the uncertainty due to the magnetic field distribution. In addition, it would be useful to measure, as precisely as possible, the residual magnetic field gradient produced by the Faraday rotator and include the effect of this gradient in the analysis of the measured signal. Since Faraday rotators make use of permanent magnets, this approach would be immune to any fluctuations and would enable adequate suppression of the effect of the magnetic field gradient, limited mostly by the accuracy of the measurement of the gradient.

4. Conceptual Modality of an Inertial Measurement Unit Employing Point Source Interferometry

To realize a PSI-based IMU suitable for an arbitrary platform that may or may not be terrestrial, we present a concrete scheme, as illustrated in Figure 5. Of course, an operational IMU also includes many parts in addition to the inertial sensors, like a clock, electronic devices, and mechanical frames. Here, we only focus on the inertial sensors themselves, assuming the existence of the other necessary parts. To simplify the discussion, we defer to the next section the technical details necessary for augmenting this system with LMT for enhancing sensitivity. A single MOT inside a spherical vacuum chamber is to be used for such an IMU. One pair of beams for the MOT, denoted as MOT 1 and MOT   1 , is applied along the x axis, as shown in the top panel of Figure 5. The other two pairs are applied in the y-z plane (MOT 2, MOT   2 , MOT 3, MOT   3 ), as shown in the bottom panel of Figure 5. Additional beams are used to realize three different PSIs orthogonal to one another. For each PSI, a pair of Raman beams and an imaging beam are first combined and sent through an optical fiber.
Consider first the case of one of these PSIs, denoted as PSI-1. The propagation axis for PSI-1 is along the z axis (PSI 1), as shown in the top panel of Figure 5. We assume that absorptive instead of fluorescence imaging is to be used so that the cameras do not need to be placed very close to the atomic cloud. The imaging system for PSI-1 is also shown in the top panel of Figure 5. The Raman beams have the polarization of ( | x + | y ) / 2 , where | x ( y ) denotes the linear polarization along the x ( y ) axis. The imaging beam has the polarization of ( | x | y ) / 2 . The Raman beams and imaging beams are aligned with the fast and the slow axis of the optical fiber. After they pass through the upper quarter waveplate, the Raman beams become σ + -polarized and the imaging beam σ -polarized. The fast axis of the lower quarter waveplate is aligned with the slow axis of the upper one so that the beams are all restored to their original linear polarizations. Then a Faraday rotator turns the polarization of the Raman beams to | y and the imaging beam to | x . Given the state-of-the-art technology, the aperture of the Faraday rotator will not be sufficiently large for the Raman beams. To circumvent this problem, a pair of lenses can be used (not shown in Figure 5) to reduce the size of the optical beams before entering the Faraday rotator. Of course, this would introduce a scale factor between the actual angle of rotation experienced by the reflected beams at the atomic cloud and the angle of rotation of the retro-reflecting mirror, and this factor has to be taken into account when using such a rotation to calibrate the rotation sensitivity of the PSI [26].
The Raman beams are transmitted through a PBS and the imaging beam is reflected by the PBS to the camera. The retroreflected Raman beams have the polarization of ( | x | y ) / 2 after they pass through the Faraday rotator for the second time. In this way, after they pass through the lower quarter waveplate, they become σ + -polarized again. It should be noted that the Faraday rotator is necessary for restoring the polarization after the Raman beam is retroreflected. We assume that the reflections from the windows can be ignored due to either antireflection coating or a slight angle between the Raman beams and the normal direction of the windows. In what follows, we will use the following notations for different components of the Raman beams. Specifically, the Raman beams propagating in the + z ^ ( z ^ ) direction will be denoted as R 1 + z ( R 1 z ) and R 2 z ( R 2 + z ) . The other two PSIs (PSI-2 and PSI-3) have propagation axes in the x-y plane, as shown in the bottom panel of Figure 5. These two PSIs are configured in a manner identical to that of PSI-1.
Here, MOT 2 and MOT   2 are a pair of counter-propagating beams for the magneto-optic trap (MOT). So are MOT 3 and MOT   3 . The remaining pair needed for the MOT is not shown in this view but rather in the diagram at the bottom, since they propagate along the x direction. PSI-1 represents all the beams used for the PSI process along the z axis. Specifically, the red arrows represent the Raman beams, and the blue ones represent the imaging beams. The green rectangles represent quarter waveplates and the black boxes represent Faraday rotators. The quarter waveplates and the Faraday rotator are configured in such a way that the Raman beams pass through the PBS and are retroreflected while the imaging beam is reflected by the PBS to the camera. The Faraday rotator is necessary since the incident and the retroreflected Raman beams are both σ + -polarized in the vacuum chamber. The diagram on the bottom shows a cross-sectional view in the x-y plane without showing the beams that are already illustrated in the top diagram. Here PSI-2 and PSI-3 represent the other two sets of beams (Raman beams and imaging beams) for the third PSI process in the x-y plane. The waveplates for these PSIs are configured in a manner analogous to that described for PSI-1.
To generate an offset velocity along each of the three PSI axes, we propose the use of moving optical molasses [2]. In what follows, this operation is referred to as launching. For each PSI, the moving optical molasses is created by reducing the frequencies of some MOT beams. Consider first the case of PSI-1. For this PSI, we have to reduce the frequencies of MOT   2 and MOT   3 . This will produce a velocity along the MOT   2   -   MOT   2 axis and the MOT   3   -   MOT   3 axis. Two of the velocity components will cancel each other, while the other two will add to each other, thus generating a net velocity along the z-axis. Using similar arguments, it is easy to determine the MOT beams whose frequencies must be reduced for the other two PSIs. The complete list for the MOT beams whose frequencies need to be reduced for each of the three PSIs is shown in Table 1. It should be noted that under this process the atoms are adiabatically dragged along by the moving dipole force potentials produced by the molasses beam. As such, the velocity of the atoms at the start of the interferometry process would be essentially independent of any ambient acceleration, such as the one due to gravity in a terrestrial apparatus or those due to vibrations.
We note that both co-propagating and counter-propagating Raman transitions can be excited by the Raman beams, as illustrated schematically in Figure 6, using the case of the D2 manifold in 87Rb for concreteness. In Figure 6a, we show the process that would generate co-propagating Raman excitations in both + z ^ and z ^ directions. It should be noted that for a co-propagating Raman excitation, the difference in the Doppler shifts is very small and can be ignored. In this diagram, we have considered only the Raman transitions that couple the F = 1 , m F = 0 and F = 2 , m F = 0 Zeeman sublevels, under the assumption that the atoms in the other Zeeman sublevels would be blown away prior to the PSI operation, as discussed later. In Figure 6b we show one possible counter-propagating Raman transition, and in Figure 6c we show the process that would generate the other counter-propagating Raman excitation. As indicated in these figures, these two types of counter-propagating Raman transitions would have opposite Doppler shifts. For a given spread of velocities in the atoms, the velocity imparted by the launching process has to be large enough to distinguish between these three types of Raman transitions [27].
The launching technique has two advantages compared to the case of free fall employed in a conventional, one-dimensional PSI. The first advantage is that this technique makes it possible to make use of Doppler shifts to discriminate between the three types of Raman transitions discussed earlier for any orientation of the PSI, including the case when it is horizontal. Of course, for a horizontal PSI, the effect of the falling of the atoms transverse to the Raman beams needs to be considered if operating the IMU terrestrially or in a near-Earth platform. Specifically, the value of Raman pulse sequence time, 2 T , needs be chosen in a manner that balances the trade-off between the effect of σ f / σ 0 shown in Figure 3 and the falling distance. As described earlier, a reasonable value of the sequence time is 2 T = 40   ms , which yields a value of ~80% for the ratio of the actual sensitivity to the ideal one. For this choice of the sequence time, the falling distance would be about 8 mm. In order to ensure that such a drop does not produce a significant change in the Raman Rabi frequency, it would be necessary to ensure that the radius of each of the Raman beams be at least ~4 cm. Alternatively, one can choose to use a smaller value of the sequence time at the expense of reducing the ratio of the actual sensitivity to the ideal one.
The second advantage is that the atomic cloud will expand less when gaining the offset velocity, for two reasons. First, the acceleration induced by a moving optical molasses can be much higher than gravitational acceleration and shorten the time of expansion. For example, in Ref. [28], atoms are accelerated to 2.6 m s 1 within 0.5 ms. To impart such an offset velocity with gravity, 270 ms is needed. Second, the atomic cloud expands much more slowly in an optical molasses field. For example, in Ref. [29], the e 2 radius of the atomic cloud increases by 0.2 mm within 100 ms in the molasses field. The atoms released from this optical molasses are at a temperature of 6 µK. If the free-fall approach were to be used for such an ensemble of atoms, the radius would increase by 4.8 mm within 100 ms. If the atomic cloud remains relatively small at the application of the first Raman pulse, with a fixed constraint on the final size of the atomic cloud, the dark period duration T can be longer, which increases the phase shift.
The state selection can be implemented with the counter-propagating Raman pulse [28,30,31] and a blow-away pulse, realized using the imaging beam for each PSI. In this way, the atoms are not only concentrated in the F = 1 , m F = 0 Zeeman substates but also at a lower temperature longitudinally due to the high Doppler sensitivity of the counter-propagating Raman transition. The transverse temperature of the atoms would remain unaffected by this process.

5. Incorporation of Large Momentum Transfer in the PSI-Based IMU

We next discuss the method to implement LMT with such a PSI-based IMU. It is evident that the LMT process described in Figure 1 can be applied to each of the three PSIs. In Ref. [14], we presented a detailed analysis of how the enhancement in sensitivity varies with increasing order of LMT. The phase shift increases with the order of LMT according to the expression derived above, causing narrowing of the interference fringes. However, as the order of LMT increases, the fringe amplitude decreases due to increasing Doppler shift and spontaneous emission. Therefore, there exists an optimal order of LMT that maximizes the sensitivity. The optimal order and the maximum sensitivity increase monotonically with the intensity of the Raman beams. The results of this analysis remain valid for each of the three PSIs in the IMU.
It should be noted that, for the modality described in Figure 5, no additional optical beams or hardware are needed for implementing the LMT process for any order. To see why, note that for the LMT protocol illustrated in Figure 7a, the effective propagation directions of the (counter-propagating) Raman beams need to be swapped for some π pulses. As illustrated earlier in Figure 7b, there already exist two pairs of counter-propagating Raman beams in opposite effective directions. For concreteness, we assume that the two frequencies for the Raman excitation are generated with an electro-optical modulator (EOM) driven by a voltage-controlled oscillator (VCO). When the atoms move with an offset velocity parallel to the Raman beams, the resonant frequencies of these two pairs of Raman beams are different due to the Doppler shift. Therefore, by tuning the frequency of the VCO, it is possible to make the atoms experience Raman transitions due to only one of these counter-propagating Raman beams and not the other. Thus, the propagation directions of the Raman beams can be effectively swapped by simply tuning the frequency of the VCO. The timing of the VCO frequency necessary for the n = 2 LMT protocol is illustrated in Figure 7b. The Raman pulses are typically on the order of a few microseconds, and the frequency jump shown in Figure 7b can be completed in 0.1 ms (corresponding to a modulation bandwidth of 100 kHz, which is commonly achievable). These time scales are much shorter than the interrogation time. Therefore, it is generally not difficult to fit in all the LMT pulses within the interrogation period.

6. Specific Layout of a PSI-Based IMU Using 87Rb Atoms

For concreteness, a possible implementation of a PSI-based IMU employing 87Rb is shown in Figure 8. Figure 8a shows the layout of the optical beams. Only one laser is needed in this implementation, assuming it has high enough output power. For example, a Toptica TAPro with an output of 4 W should work for such a design. The laser frequency is locked to the cross-over saturated absorption resonance occurring between the S 1 / 2 , F = 2 to P 3 / 2 , F = 1 transition and the S 1 / 2 , F = 2 to P 3 / 2 , F = 3 transition. Under this condition, the laser is 212 MHz red-detuned from the S 1 / 2 , F = 2 to P 3 / 2 , F = 3 transition [32]. The part of the laser output to be used for producing the MOT and molasses cooling is split into six separate beams (in Figure 8a, we have shown explicitly only one of these six beams). The beam for each MOT is sent through an upshifting AOM in the double-pass configuration, operating at a frequency of 100 MHz so that each MOT beam is detuned by 12 MHz below the S 1 / 2 , F = 2 to P 3 / 2 , F = 3 transition. The MOT beams turn into molasses beams when each of the AOMs is tuned to 60 MHz [10]. In this way, the detuning of the molasses beams is increased to 92 MHz and the intensity is also significantly reduced because the modulation frequency is far from the central frequency of the AOMs. The double-pass configuration ensures the stability of the alignment when the modulation frequency for the AOMs varies. Note that six different AOMs are needed in order to be able to generate the moving molasses for the launching process.
The repump frequency is produced by modulating the primary MOT beam (before it is split six-ways) with an EOM driven at a modulation frequency of 6.623 GHz. For this choice of the modulation frequency, the +1 order sideband of the output of the EOM becomes resonant to the S 1 / 2 , F = 1 to P 3 / 2 , F = 2 transition, as needed for repumping. It should be noted that when the molasses cooling process is activated, the detuning of the repump beam from the S 1 / 2 , F = 1 to P 3 / 2 , F = 2 transition is ramped up to 80 MHz. Since the rate of leakage to S 1 / 2 , F = 1 during the molasses cooling process decreases along with the detuning, the repumping rate is still adequate [3].
The Raman beams are produced in the following way. The majority of the laser output first passes through an AOM that down-shifts the beam frequency by 500 MHz and then passes through an EOM modulated with the Raman transition frequency, which is about 6.835 GHz plus the Doppler shift resulting from the launching process. The carrier and the +1 order sideband work as the Raman frequency components. The driving power for the EOM should be adjusted to such a value that the light shifts induced by the two Raman beams are canceled. It should be noted that although this beam is intense, for example, on the order of hundreds of mW, the Raman pulses are too short to cause photorefractive damage to the EOM [3]. The AOM serves two purposes. First, it makes it possible to turn on and off the Raman beams rapidly. Second, it produces a large common detuning for them. The PBSs enable this beam to be directed to any one of the three axes depending on the states of the variable retarders VR 1 and VR 2. Here, variable retarders instead of Pockels cells are used because a fast switch process is not necessary and variable retarders do not need to be driven with high voltages. It should be noted that for each axis of operation, all output power from the AOM is directed to only one fiber port, instead of being split into three beams. The probe beam is resonant to the S 1 / 2 , F = 2 to P 3 / 2 , F = 3 transition, which is produced by blue-shifting a piece of the laser output by 212 MHz. The imaging beam can also be directed to any of the three axes depending on the states of the variable retarders VR 3 and VR 4.
We next describe the steps to operate each of the PSIs for the IMU. First, atoms are captured in an MOT. Then, the MOT is turned into optical molasses by turning off the MOT magnetic field and shifting the modulation frequency for the AOMs from 100 MHz to 60 MHz. Next, the frequencies of some molasses beams are reduced to produce a moving molasses field, using the protocol summarized earlier in Table 1. Upon the completion of the launching with the moving molasses, the molasses beams are turned off so that the optical pumping also gets turned off. At this point, the atoms are all in the S 1 / 2 , F = 2 hyperfine state, with populations distributed among the Zeeman sublevels defined with respect to a quantization axis that is the same as the propagation axis of the PSI being realized. This is now followed by the implementation of a state selection process. This process consists of the following steps. First, an offset magnetic field parallel to the Raman beams is turned on. Then, a Raman π pulse is applied, with the EOM tuned to a frequency that causes a resonant, counter-propagating Raman transition (with the effective direction of + z ) between the F = 2 , m F = 0 state and the F = 1 , m F = 0 . The offset field should be strong enough to avoid excitation of Raman transitions of the other Zeeman substates. The intensity of the Raman beams for this step should be small enough so that they can select atoms in a narrow longitudinal velocity range [30,31]. The state selection process is followed by the application of the imaging beam to blow away the remaining atoms in the S 1 / 2 , F = 2 state.
After the state selection, the Raman pulses are applied to implement the LMT-augmented PSI protocol. For the LMT process, the propagation directions of the two Raman beams need to be swapped for some π pulses, as discussed above. However, it should be noted that in this configuration, there already exist two pairs of counter-propagating Raman beams in opposite effective directions. Therefore, by tuning the EOM from one Doppler-broadened Raman resonant peak to the other, the propagation directions of the Raman beams can be effectively swapped. Finally, the spatial population distribution of state S 1 / 2 , F = 2 is imaged with the imaging beam and the camera.

7. Discussion and Conclusions

We have presented a systematic and rigorous analysis of the sensitivity and bandwidth of accelerometry and rotation sensing with a point source atom interferometer employing large momentum transfer with molasses-launched atoms. This analysis yields a generalized expression for these sensitivities in terms of the signals measured by each pixel of a camera used for monitoring the distributed signal. We show that when the acceleration or rotation exceeds certain levels, it is possible to express the sensitivity in a closed form. Otherwise, the sensitivity can only be determined via a numerical evaluation of the general expression. We also show how the molasses-based launching process makes it possible to realize the LMT process without the need to physically change directions of the Raman pulses, thus significantly simplifying the apparatus and reducing the amount of time needed to make the measurements. These advantages become more important when this process is used for realizing an IMU. We describe an explicit scheme for a such an IMU and determine the expected sensitivity and bandwidth thereof for experimentally accessible parameters. Of course, for any specific apparatus, experimental studies need to be carried out in order to evaluate and suppress the effects of systematic sources of error.

Author Contributions

Conceptualization, J.L. and S.M.S.; methodology, J.L.; software, J.L.; validation, T.K. and S.M.S.; resources, S.M.S. and J.B.; writing-original draft preparation, J.L.; writing-review and editing, T.K. and S.M.S.; funding acquisition, S.M.S. and J.B. All authors have read and agreed to the published version of the manuscript.

Funding

National Aeronautics and Space Administration (80NSSC20C0161); U.S. Department of Defense (W911NF202076); Office of Naval Research (N00014-19-1-2181).

Data Availability Statement

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Conflicts of Interest

The authors declare no conflicts of interests.

Appendix A

Here, we derive the phase shift, due to both acceleration and rotation, for each atom in a PSI augmented by large momentum transfer (LMT). Consider first the acceleration-induced phase shift. To determine this shift in the presence of LMT, it is convenient to review briefly the derivation for the conventional π / 2 - π - π / 2 atom interferometer, which only includes pulses A 0 , B 0 , and C 0 in Figure 7. The phase shift can be expressed as
ϕ 0 = ϕ A 0 + ϕ C 0 ϕ B 0 ϕ B 0 = ( ϕ C 0 ϕ B 0 + ϕ B 0 2 ) ( ϕ B 0 + ϕ B 0 2 ϕ A 0 ) ( ϕ C 0 ϕ B 0 ) ( ϕ B 0 ϕ A 0 )
where ϕ A 0 denotes the relative phase between the two Raman beams at pulse A 0 , ϕ B 0 ( ) denotes this relative phase at the upper (lower) arm at pulse B 0 , and ϕ B 0 ( ϕ B 0 + ϕ B 0 ) / 2 the Raman beam relative phase at the mean position at B 0 . Then the acceleration-induced phase shift can be derived to be
ϕ 0 = ( ϕ C 0 ϕ B 0 ) ( ϕ B 0 ϕ A 0 ) = k eff ( Δ r C 0 , B 0 Δ r B 0 , A 0 ) = k eff ( v ¯ C 0 , B 0 v ¯ B 0 , A 0 ) T = k eff ( a T ) T = k eff a T 2
For simplicity, in what follows, the displacement or velocity of the mean position of the atoms are referred to as the displacement or velocity of the atoms. In Equation (A2), Δ r C 0 , B 0 , for example, denotes the displacement of the atoms between pulse C 0 and B 0 , v ¯ C 0 , B 0 denotes the average velocity of the atoms in this interval, k eff is the effective wavenumber of the counter-propagating Raman beams, whose absolute value is approximately 2 k , and a is the linear acceleration. It should be noted that the relation v ¯ C 0 , B 0 v ¯ B 0 , A 0 = a T is used in the second to last step of Equation (A2). In the case of LMT, the four additional pulses A 1 , B 1 , B 1 , and C 1 yield an additional phase shift, given by
ϕ 1 = 2 [ ( ϕ C 1 ϕ B 1 ) ( ϕ B 1 ϕ A 1 ) ] = 2 k eff ( Δ r C 1 , B 1 Δ r B 1 , A 1 ) = 2 k eff ( v ¯ C 1 , B 1 v ¯ B 1 , A 1 ) T 1 = 2 k eff ( a T ) T 1 = 2 k eff a T T 1
For the case of an LMT process with an arbitrary order n, the expression of the total phase shift can be easily generalized to be ϕ = k eff a ( T + 2 j = 1 n T j ) .
Consider next the rotation-induced phase shift, which comes from the rotation of the vector k eff . The shift resulting from the original three pulses A 0 , B 0 , C 0 still equals the difference between ϕ C 0 ϕ B 0 and ϕ B 0 ϕ A 0 . The phase ϕ C 0 ϕ B 0 is calculated to be
ϕ C 0 ϕ B 0 = k C 0 r C 0 k B 0 r B 0 = k C 0 ( r C 0 + r B 0 2 + r C 0 r B 0 2 ) k B 0 ( r C 0 + r B 0 2 r C 0 r B 0 2 ) k C 0 ( r ¯ C 0 , B 0 + Δ r C 0 , B 0 ) k B 0 ( r ¯ C 0 , B 0 Δ r C 0 , B 0 ) = ( k C 0 k B 0 ) r ¯ C 0 , B 0 + ( k C 0 + k B 0 ) Δ r C 0 , B 0 Δ k C 0 , B 0 r ¯ C 0 , B 0 + 2 k ¯ C 0 , B 0 Δ r C 0 , B 0
Similarly, it can be shown that ϕ B 0 ϕ A 0 = Δ k B 0 , A 0 r ¯ B 0 , A 0 + 2 k ¯ B 0 , A 0 Δ r B 0 , A 0 . Noting that Δ k C 0 , B 0 = Δ k B 0 , A 0 k eff × Ω T in the limit Ω T 1 and that Δ r C j , B j = Δ r B j , A j = r / 2 , where Ω is the angular velocity and r is the displacement of the atoms from pulse A 0 to pulse C 0 , the net phase shift resulting from the four pulses can be expressed as
ϕ 0 = ( ϕ C 0 ϕ B 0 ) ( ϕ B 0 ϕ A 0 ) ( k eff × Ω T ) ( r ¯ C 0 , B 0 r ¯ B 0 , A 0 ) + ( k ¯ C 0 , B 0 k ¯ B 0 , A 0 ) r 2 ( k eff × Ω T ) r 2 + ( k eff × Ω T ) r 2 = ( k eff × Ω T ) r
Following the same steps, it can also be shown that the rotation-induced phase shift resulting from A j , B j , B j , and C j is 2 ( k eff × Ω T j ) r . Summing up the phase shifts resulting from all pulses, the total phase shift is calculated to be ϕ = ( k eff × Ω ) r ( T + 2 j = 1 n T j ) .

References

  1. Canuel, B.; Leduc, F.; Holleville, D.; Gauguet, A.; Fils, J.; Virdis, A.; Clairon, A.; Dimarcq, N.; Bordé, C.J.; Landragin, A.; et al. Six-axis inertial sensor using cold-atom interferometry. Phys. Rev. Lett. 2006, 97, 010402. [Google Scholar] [CrossRef] [PubMed]
  2. Barrett, B.; Cheiney, P.; Battelier, B.; Napolitano, F.; Bouyer, P. Multidimensional atom optics and interferometry. Phys. Rev. Lett. 2019, 122, 043604. [Google Scholar] [CrossRef]
  3. Wu, X.; Zi, F.; Dudley, J.; Bilotta, R.J.; Canoza, P.; Müller, H. Multiaxis atom interferometry with a single-diode laser and a pyramidal magneto-optical trap. Optica 2017, 4, 1545–1551. [Google Scholar] [CrossRef]
  4. Kwolek, J.M.; Black, A.T. Continuous sub-Doppler-cooled atomic beam interferometer for inertial sensing. Phys. Rev. Appl. 2022, 17, 024061. [Google Scholar] [CrossRef]
  5. Bongs, K.; Holynski, M.; Vovrosh, J.; Bouyer, P.; Condon, G.; Rasel, E.; Schubert, C.; Schleich, W.P.; Roura, A. Taking atom interferometric quantum sensors from the laboratory to real-world applications. Nat. Rev. Phys. 2019, 1, 731–739. [Google Scholar] [CrossRef]
  6. Narducci, F.A.; Black, A.T.; Burke, J.H. Advances toward fieldable atom interferometers. Adv. Phys. X 2022, 7, 1946426. [Google Scholar] [CrossRef]
  7. Dickerson, S.M.; Hogan, J.M.; Sugarbaker, A.; Johnson, D.M.; Kasevich, M.A. Multiaxis inertial sensing with long-time point source atom interferometry. Phys. Rev. Lett. 2013, 111, 083001. [Google Scholar] [CrossRef]
  8. Hoth, G.W.; Pelle, B.; Riedl, S.; Kitching, J.; Donley, E.A. Point source atom interferometry with a cloud of finite size. Appl. Phys. Lett. 2016, 109, 071113. [Google Scholar] [CrossRef]
  9. Sugarbaker, A.; Dickerson, S.M.; Hogan, J.M.; Johnson, D.M.; Kasevich, M.A. Enhanced atom interferometer readout through the application of phase shear. Phys. Rev. Lett. 2013, 111, 113002. [Google Scholar] [CrossRef]
  10. Chen, Y.J.; Hansen, A.; Hoth, G.W.; Ivanov, E.; Pelle, B.; Kitching, J.; Donley, E.A. Single-source multiaxis cold-atom interferometer in a centimeter-scale cell. Phys. Rev. Appl. 2019, 12, 014019. [Google Scholar] [CrossRef]
  11. Avinadav, C.; Yankelev, D.; Shuker, M.; Firstenberg, O.; Davidson, N. Rotation sensing with improved stability using point-source atom interferometry. Phys. Rev. A 2020, 102, 013326. [Google Scholar] [CrossRef]
  12. Li, J.; Da Silva, G.R.; Kain, S.; Shahriar, S.M. Generalized echo squeezing protocol with near-Heisenberg-limit sensitivity and strong robustness against detection noise and variation in squeezing parameter. Phys. Rev. A 2023, 107, 032610. [Google Scholar] [CrossRef]
  13. Fang, R.; Sarkar, R.; Shahriar, S.M. Enhancing the sensitivity of an atom interferometer to the Heisenberg limit using increased quantum noise. J. Opt. Soc. Am. B 2020, 37, 1974–1986. [Google Scholar] [CrossRef]
  14. Li, J.; RM da Silva, G.; Huang, W.C.; Fouda, M.; Bonacum, J.; Kovachy, T.; Shahriar, S.M. High sensitivity multi-axes rotation sensing using large momentum transfer point source atom interferometry. Atoms 2021, 9, 51. [Google Scholar] [CrossRef]
  15. Hoth, G.W.; Pelle, B.; Kitching, J.; Donley, E.A. Trade-offs in size and performance for a point source interferometer gyroscope. In Proceedings of the 2017 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL), Kauai, HI, USA, 27–30 March 2017; IEEE: Piscataway, NJ, USA, 2017; pp. 4–7. [Google Scholar]
  16. Li, J.; Da Silva, G.R.; Kain, S.; Bonacum, J.; Smith, D.D.; Kovachy, T.; Shahriar, S.M. Spin-squeezing-enhanced dual-species atom interferometric accelerometer employing large momentum transfer for precision test of the equivalence principle. Phys. Rev. D 2023, 108, 024011. [Google Scholar] [CrossRef]
  17. McGuirk, J.M.; Snadden, M.J.; Kasevich, M.A. Large area light-pulse atom interferometry. Phys. Rev. Lett. 2000, 85, 4498. [Google Scholar] [CrossRef] [PubMed]
  18. Kotru, K.; Butts, D.L.; Kinast, J.M.; Stoner, R.E. Large-area atom interferometry with frequency-swept Raman adiabatic passage. Phys. Rev. Lett. 2015, 115, 103001. [Google Scholar] [CrossRef] [PubMed]
  19. Butts, D.L.; Kotru, K.; Kinast, J.M.; Radojevic, A.M.; Timmons, B.P.; Stoner, R.E. Efficient broadband Raman pulses for large-area atom interferometry. JOSA B 2013, 30, 922–927. [Google Scholar] [CrossRef]
  20. Knoblauch, A. Closed-form expressions for the moments of the binomial probability distribution. SIAM J. Appl. Math. 2008, 69, 197–204. [Google Scholar] [CrossRef]
  21. Barrett, B.; Antoni-Micollier, L.; Chichet, L.; Battelier, B.; Léveque, T.; Landragin, A.; Bouyer, P. Dual matter-wave inertial sensors in weightlessness. Nat. Commun. 2016, 7, 13786. [Google Scholar] [CrossRef]
  22. Chiow, S.W.; Kovachy, T.; Chien, H.C.; Kasevich, M.A. 102 ℏ k large area atom interferometers. Phys. Rev. Lett. 2011, 107, 130403. [Google Scholar] [CrossRef] [PubMed]
  23. Wilkason, T.; Nantel, M.; Rudolph, J.; Jiang, Y.; Garber, B.E.; Swan, H.; Carman, S.P.; Abe, M.; Hogan, J.M. Atom interferometry with floquet atom optics. Phys. Rev. Lett. 2022, 129, 183202. [Google Scholar] [CrossRef] [PubMed]
  24. Woodgate, G.K. Elementary Atomic Structure, 2nd ed.; Oxford University Press: Oxford, UK, 1980; pp. 193–194. [Google Scholar]
  25. Breit, G.; Rabi, I.I. Measurement of nuclear spin. Phys. Rev. 1931, 38, 2082–2083. [Google Scholar] [CrossRef]
  26. Glick, J.; Chen, Z.; Deshpande, T.; Wang, Y.; Kovachy, T. Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry. AVS Quantum Sci. 2024, 6, 014402. [Google Scholar] [CrossRef]
  27. Gauguet, A.; Mehlstäubler, T.E.; Lévèque, T.; Le Gouët, J.; Chaibi, W.; Canuel, B.; Clairon, A.; Dos Santos, F.P.; Landragin, A. Off-resonant Raman transition impact in an atom interferometer. Phys. Rev. A 2008, 78, 043615. [Google Scholar] [CrossRef]
  28. Kasevich, M.; Chu, S. Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer. Appl. Phys. B 1992, 54, 321–332. [Google Scholar] [CrossRef]
  29. Gerz, C.; Hodapp, T.W.; Jessen, P.; Jones, K.M.; Phillips, W.D.; Westbrook, C.I.; Molmer, K. The temperature of optical molasses for two different atomic angular momenta. Europhys. Lett. 1993, 21, 661. [Google Scholar] [CrossRef]
  30. Kasevich, M.; Weiss, D.S.; Riis, E.; Moler, K.; Kasapi, S.; Chu, S. Atomic velocity selection using stimulated Raman transitions. Phys. Rev. Lett. 1991, 66, 2297. [Google Scholar] [CrossRef]
  31. Geiger, R.; Ménoret, V.; Stern, G.; Zahzam, N.; Cheinet, P.; Battelier, B.; Villing, A.; Moron, F.; Lours, M.; Bidel, Y.; et al. Detecting inertial effects with airborne matter-wave interferometry. Nat. Commun. 2011, 2, 474. [Google Scholar] [CrossRef]
  32. Steck, D.A. Rubidium 87 D Line Data. 2001. Available online: http://steck.us/alkalidata (accessed on 28 May 2024).
Figure 1. Illustration of the pulse sequence for the LMT protocol for n = 2 . For nth order LMT, 4n  π pulses are added. A pulse with an odd (even) subsript has an effective propagation direction opposite (identical) to that of the three original pulses.
Figure 1. Illustration of the pulse sequence for the LMT protocol for n = 2 . For nth order LMT, 4n  π pulses are added. A pulse with an odd (even) subsript has an effective propagation direction opposite (identical) to that of the three original pulses.
Atoms 12 00032 g001
Figure 2. Accelerometry sensitivity of a PSI as a function of k Ω σ f for Gaussian f ( x ) when (a) ϕ a = 0 and (b) ϕ a = π / 2 . When k Ω σ f is close to zero, the sensitivity depends on ϕ a . As k Ω σ f increases to about π , the sensitivity converges to the analytical expressions.
Figure 2. Accelerometry sensitivity of a PSI as a function of k Ω σ f for Gaussian f ( x ) when (a) ϕ a = 0 and (b) ϕ a = π / 2 . When k Ω σ f is close to zero, the sensitivity depends on ϕ a . As k Ω σ f increases to about π , the sensitivity converges to the analytical expressions.
Atoms 12 00032 g002
Figure 3. (a) Optimal order of LMT as a function the Raman beam intensity. For nth order of LMT, k t = ( 2 n + 1 ) k eff . For the Raman transition F = 1 , m F = 0 F = 2 , m F = 0 , I s = 5.01   mW cm 2 . (b) LMT-induced sensitivity enhancement factor as a function of the light intensity.
Figure 3. (a) Optimal order of LMT as a function the Raman beam intensity. For nth order of LMT, k t = ( 2 n + 1 ) k eff . For the Raman transition F = 1 , m F = 0 F = 2 , m F = 0 , I s = 5.01   mW cm 2 . (b) LMT-induced sensitivity enhancement factor as a function of the light intensity.
Atoms 12 00032 g003
Figure 4. Ratio of the actual sensitivity to the ideal sensitivity for σ 0 = 0.2   mm and k Ω = π / 2   cm 1 , when the finite initial size of the atomic cloud is considered. The temperature of the atoms is set at 6 µK.
Figure 4. Ratio of the actual sensitivity to the ideal sensitivity for σ 0 = 0.2   mm and k Ω = π / 2   cm 1 , when the finite initial size of the atomic cloud is considered. The temperature of the atoms is set at 6 µK.
Atoms 12 00032 g004
Figure 5. Schematic illustration of a three-dimensional PSI apparatus. The diagram on the top shows a cross-sectional view in the y-z plane. The red arrows reprenst the Raman beams and the blue ones the imaging beams.
Figure 5. Schematic illustration of a three-dimensional PSI apparatus. The diagram on the top shows a cross-sectional view in the y-z plane. The red arrows reprenst the Raman beams and the blue ones the imaging beams.
Atoms 12 00032 g005
Figure 6. Coupling between F = 1 , m F = 0 and F = 2 , m F = 0 Zeeman ground states of 87Rb induced by copropagating and counter-propagating Raman beams along the z axis. Here, v is the amplitude of the atomic offset velocity in the z direction. The offset velocity is assumed to be in the z direction. R 1 ( 2 ) ± z represents the higher (lower)-frequency Raman beam in the ± z direction. The wavenumbers of both Raman beams are denoted as k , and the small wavenumber difference between them is neglected. In the designations of the quantum states, the last element indicates the momentum in the z-direction. The transitions driven by three pairs of Raman beams have three different resonant frequencies in the presence of a offset velocity. (a) Coupling induced by copropagating Raman beams. The transition frequency is simply the hyperfine splitting. (b) Coupling induced by R 1 + z and R 2 z . The transition frequency is shifted up by 2 k v + ( 2 k ) 2 / 2 m , where 2 k v is Doppler shift and ( 2 k ) 2 / 2 m is the recoil frequency. (c) Coupling induced by R 1 z and R 2 + z . The transition frequency is shifted down by 2 k v + ( 2 k ) 2 / 2 m .
Figure 6. Coupling between F = 1 , m F = 0 and F = 2 , m F = 0 Zeeman ground states of 87Rb induced by copropagating and counter-propagating Raman beams along the z axis. Here, v is the amplitude of the atomic offset velocity in the z direction. The offset velocity is assumed to be in the z direction. R 1 ( 2 ) ± z represents the higher (lower)-frequency Raman beam in the ± z direction. The wavenumbers of both Raman beams are denoted as k , and the small wavenumber difference between them is neglected. In the designations of the quantum states, the last element indicates the momentum in the z-direction. The transitions driven by three pairs of Raman beams have three different resonant frequencies in the presence of a offset velocity. (a) Coupling induced by copropagating Raman beams. The transition frequency is simply the hyperfine splitting. (b) Coupling induced by R 1 + z and R 2 z . The transition frequency is shifted up by 2 k v + ( 2 k ) 2 / 2 m , where 2 k v is Doppler shift and ( 2 k ) 2 / 2 m is the recoil frequency. (c) Coupling induced by R 1 z and R 2 + z . The transition frequency is shifted down by 2 k v + ( 2 k ) 2 / 2 m .
Atoms 12 00032 g006
Figure 7. (a) Illustration of the pulse sequence for the LMT protocol for n = 2 . (b) Timing of the VCO frequency for this protocol. The VCO determines the relative frequency between the two Raman beams. When the VCO is tuned to ω HFS + ( k eff ) 2 / 2 m + k v , R 1 + z and R 2 z take effect. When the VCO is tuned to ω HFS ( k eff ) 2 / 2 m k v , R 1 z and R 2 + z take effect. See text for details.
Figure 7. (a) Illustration of the pulse sequence for the LMT protocol for n = 2 . (b) Timing of the VCO frequency for this protocol. The VCO determines the relative frequency between the two Raman beams. When the VCO is tuned to ω HFS + ( k eff ) 2 / 2 m + k v , R 1 + z and R 2 z take effect. When the VCO is tuned to ω HFS ( k eff ) 2 / 2 m k v , R 1 z and R 2 + z take effect. See text for details.
Atoms 12 00032 g007
Figure 8. Layout of a PSI-based IMU using 87Rb atoms. (a) Optical system. Each of the six MOT/molasses beams is produced and controlled by an AOM optimized at a modulation frequency of 100 MHz. The modulation frequency is ramped down to 60 MHz during the process of optical molasses cooling. These beams also pass through an EOM to generate the repumping frequency component. The Raman beams (red) are produced by a 500 MHz AOM and an EOM. The imaging beam (blue) is produced by an AOM tuned to 92 MHz. The Raman beams are directed to each of the three fiber ports with PBSs (black boxes with a slash inside) and variable retarders VR1 and VR 2. The imaging beam is directed to each of the three fiber ports with variable retarders VR 3 and VR 4. (b) Frequencies of the beams used in (a).
Figure 8. Layout of a PSI-based IMU using 87Rb atoms. (a) Optical system. Each of the six MOT/molasses beams is produced and controlled by an AOM optimized at a modulation frequency of 100 MHz. The modulation frequency is ramped down to 60 MHz during the process of optical molasses cooling. These beams also pass through an EOM to generate the repumping frequency component. The Raman beams (red) are produced by a 500 MHz AOM and an EOM. The imaging beam (blue) is produced by an AOM tuned to 92 MHz. The Raman beams are directed to each of the three fiber ports with PBSs (black boxes with a slash inside) and variable retarders VR1 and VR 2. The imaging beam is directed to each of the three fiber ports with variable retarders VR 3 and VR 4. (b) Frequencies of the beams used in (a).
Atoms 12 00032 g008
Table 1. Relation between the moving direction of the molasses and the frequency configuration of the beams.
Table 1. Relation between the moving direction of the molasses and the frequency configuration of the beams.
Moving Direction of the MolassesBeams Whose Frequencies Are Reduced
Propagation axis for PSI-1 MOT   2 ,   MOT   3
Propagation axis for PSI-2 MOT   1 ,   MOT   2 ,   MOT   3
Propagation axis for PSI-3 MOT   1 ,   MOT   2 ,   MOT   3
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Li, J.; Kovachy, T.; Bonacum, J.; Shahriar, S.M. Sensitivity of a Point-Source-Interferometry-Based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms. Atoms 2024, 12, 32. https://doi.org/10.3390/atoms12060032

AMA Style

Li J, Kovachy T, Bonacum J, Shahriar SM. Sensitivity of a Point-Source-Interferometry-Based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms. Atoms. 2024; 12(6):32. https://doi.org/10.3390/atoms12060032

Chicago/Turabian Style

Li, Jinyang, Timothy Kovachy, Jason Bonacum, and Selim M. Shahriar. 2024. "Sensitivity of a Point-Source-Interferometry-Based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms" Atoms 12, no. 6: 32. https://doi.org/10.3390/atoms12060032

APA Style

Li, J., Kovachy, T., Bonacum, J., & Shahriar, S. M. (2024). Sensitivity of a Point-Source-Interferometry-Based Inertial Measurement Unit Employing Large Momentum Transfer and Launched Atoms. Atoms, 12(6), 32. https://doi.org/10.3390/atoms12060032

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop