Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Study Sample and Data Collection Method
2.3. Data Management and Analyses
2.4. Statistical Analysis
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Weinberg, S.M.; Kolar, J.C. Three-Dimensional Surface Imaging: Limitations and Considerations from the Anthropometric Perspective. J. Craniofacial Surg. 2005, 16, 847–851. [Google Scholar] [CrossRef] [PubMed]
- Lee, J.D.; Nguyen, O.; Lin, Y.C.; Luu, D.; Kim, S.; Amini, A.; Lee, S.J. Facial Scanners in Dentistry: An Overview. Prosthesis 2022, 4, 664–678. [Google Scholar] [CrossRef]
- Joda, T.; Gallucci, G.O. The Virtual Patient in Dental Medicine. Clin. Oral Implant. Res. 2015, 26, 725–726. [Google Scholar] [CrossRef] [PubMed]
- Venkatesh, E.; Venkatesh Elluru, S. Cone beam computed tomography: Basics and applications in dentistry. J. Istanb. Univ. Fac. Dent. 2017, 5, 102–121. [Google Scholar] [CrossRef] [PubMed]
- Awad, D.; Reinert, S.; Kluba, S. Accuracy of Three-Dimensional Soft-Tissue Prediction Considering the Facial Aesthetic Units Using a Virtual Planning System in Orthognathic Surgery. J. Pers. Med. 2022, 12, 1379. [Google Scholar] [CrossRef]
- Hassan, B.; Greven, M.; Wismeijer, D. Integrating 3D Facial Scanning in a Digital Workflow to CAD/CAM Design and Fabricate Complete Dentures for Immediate Total Mouth Rehabilitation. J. Adv. Prosthodont. 2017, 9, 381–386. [Google Scholar] [CrossRef]
- Patel, N. Integrating Three-Dimensional Digital Technologies for Comprehensive Implant Dentistry. J. Am. Dent. Assoc. 2010, 141, 20S–24S. [Google Scholar] [CrossRef]
- Antonelli, A.; Barone, S.; Bennardo, F.; Giudice, A. Three-Dimensional Facial Swelling Evaluation of Pre-Operative Single-Dose of Prednisone in Third Molar Surgery: A Split-Mouth Randomized Controlled Trial. BMC Oral Health 2023, 23, 614. [Google Scholar] [CrossRef]
- Eastwood, P.; Gilani, S.Z.; McArdle, N.; Hillman, D.; Walsh, J.; Maddison, K.; Goonewardene, M.; Mian, A. Predicting Sleep Apnea from Three-Dimensional Face Photography. J. Clin. Sleep Med. 2020, 16, 493–502. [Google Scholar] [CrossRef]
- Ghamri, M.; Dritsas, K.; Probst, J.; Jäggi, M.; Psomiadis, S.; Schulze, R.; Verna, C.; Katsaros, C.; Halazonetis, D.; Gkantidis, N. Accuracy of Facial Skeletal Surfaces Segmented from CT and CBCT Radiographs. Sci. Rep. 2023, 13, 21002. [Google Scholar] [CrossRef]
- Weinberg, S.M.; Scott, N.M.; Neiswanger, K.; Brandon, C.A.; Marazita, M.L. Digital three-dimensional photogrammetry: Evaluation of anthropometric precision and accuracy using a Genex 3D camera system. Cleft Palate-Craniofacial J. 2004, 41, 507–518. [Google Scholar] [CrossRef] [PubMed]
- Hong, C.; Choi, K.; Kachroo, Y.; Kwon, T.; Nguyen, A.; McComb, R.; Moon, W. Evaluation of the 3dMDface System as a Tool for Soft Tissue Analysis. Orthod. Craniofacial Res. 2017, 20, 119–124. [Google Scholar] [CrossRef] [PubMed]
- Wong, J.Y.; Oh, A.K.; Ohta, E.; Hunt, A.T.; Rogers, G.D.F.; Mulliken, J.B.; Deutsch, C.K. Validity and Reliability of Craniofacial Anthropometric Measurement of 3D Digital Photogrammetric Images. Cleft Palate-Craniofacial J. 2007, 45, 232–239. [Google Scholar] [CrossRef] [PubMed]
- Zhao, Y.J.; Xiong, Y.X.; Wang, Y. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy. PLoS ONE 2017, 12, e0169402. [Google Scholar] [CrossRef]
- Piedra-Cascón, W.; Meyer, M.J.; Methani, M.M.; Revilla-León, M. Accuracy (trueness and precision) of a dual-structured light facial scanner and interexaminer reliability. J. Prosthet. Dent. 2020, 124, 567–574. [Google Scholar] [CrossRef] [PubMed]
- Andrews, J.; Alwafi, A.; Bichu, Y.M.; Pliska, B.T.; Mostafa, N.; Zou, B. Validation of Three-Dimensional Facial Imaging Captured with Smartphone-Based Photogrammetry Application in Comparison to Stereophotogrammetry System. Heliyon 2023, 9, e15834. [Google Scholar] [CrossRef]
- Breitbarth, A.; Schardt, T.; Kind, C.; Brinkmann, J.; Dittrich, P.-G.; Notni, G. Measurement Accuracy and Dependence on External Influences of the IPhone X TrueDepth Sensor. In Photonics and Education in Measurement Science; SPIE: Weinheim, Germany, 2019; p. 7. [Google Scholar]
- Rudy, H.L.; Wake, N.; Yee, J.; Garfein, E.S.; Tepper, O.M. Three-Dimensional Facial Scanning at the Fingertips of Patients and Surgeons: Accuracy and Precision Testing of IPhone X Three-Dimensional Scanner. Plast. Reconstr. Surg. 2020, 146, 1407–1417. [Google Scholar] [CrossRef]
- D’Ettorre, G.; Farronato, M.; Candida, E.; Quinzi, V.; Grippaudo, C. A Comparison between Stereophotogrammetry and Smartphone Structured Light Technology for Three-Dimensional Face Scanning. Angle Orthod. 2022, 93, 358–363. [Google Scholar] [CrossRef]
- Thurzo, A.; Strunga, M.; Havlínová, R.; Reháková, K.; Urban, R.; Surovková, J.; Kurilová, V. Smartphone-Based Facial Scanning as a Viable Tool for Facially Driven Orthodontics? Sensors 2022, 22, 7752. [Google Scholar] [CrossRef]
- Fedorov, A.; Beichel, R.; Kalpathy-Cramer, J.; Finet, J.; Fillion-Robin, J.C.; Pujol, S.; Bauer, C.; Jennings, D.; Fennessy, F.; Sonka, M.; et al. 3D Slicer as an Image Computing Platform for the Quantitative Imaging Network. Magn. Reson. Imaging 2012, 30, 1323–1341. [Google Scholar] [CrossRef]
- Anchling, L.; Hutin, N.; Huang, Y.; Barone, S.; Roberts, S.; Miranda, F.; Gurgel, M.; Turkestani, N.A.; Tinawi, S.; Bianchi, J.; et al. Automated Orientation and Registration of Cone-Beam Computed Tomography Scans. In Proceedings of the Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics); Springer: Cham, Switzerland, 2023; Volume 14242, pp. 43–58. [Google Scholar]
- Gillot, M.; Baquero, B.; Le, C.; Deleat-Besson, R.; Bianchi, J.; Ruellas, A.; Gurgel, M.; Yatabe, M.; Al Turkestani, N.; Najarian, K.; et al. Automatic Multi-Anatomical Skull Structure Segmentation of Cone-Beam Computed Tomography Scans Using 3D UNETR. PLoS ONE 2022, 17, e0275033. [Google Scholar] [CrossRef] [PubMed]
- Gillot, M.; Miranda, F.; Baquero, B.; Ruellas, A.; Gurgel, M.; Al Turkestani, N.; Anchling, L.; Hutin, N.; Biggs, E.; Yatabe, M.; et al. Automatic Landmark Identification in Cone-Beam Computed Tomography. Orthod. Craniofacial Res. 2023, 26, 560–567. [Google Scholar] [CrossRef] [PubMed]
- Toma, A.M.; Zhurov, A.I.; Playle, R.; Marshall, D.; Rosin, P.L.; Richmond, S. The assessment of facial variation in 4747 British school children. Eur. J. Orthod. 2012, 34, 655–664. [Google Scholar] [CrossRef] [PubMed]
- Plooij, J.M.; Swennen, G.R.J.; Rangel, F.A.; Maal, T.J.J.; Schutyser, F.A.C.; Bronkhorst, E.M.; Kuijpers–Jagtman, A.M.; Bergé, S.J. Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry. Int. J. Oral Maxillofac. Surg. 2009, 38, 267–273. [Google Scholar] [CrossRef] [PubMed]
- Secher, J.J.; Darvann, T.A.; Pinholt, E.M. Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging. J. Cranio-Maxillofac. Surg. 2017, 45, 1662–1670. [Google Scholar] [CrossRef] [PubMed]
- Liu, J.; Zhang, C.; Cai, R.; Yao, Y.; Zhao, Z.; Liao, W. Accuracy of 3-Dimensional Stereophotogrammetry: Comparison of the 3dMD and Bellus3D Facial Scanning Systems with One Another and with Direct Anthropometry. Am. J. Orthod. Dentofac. Orthop. 2021, 160, 862–871. [Google Scholar] [CrossRef]
- Aung, S.C.; Ngim, R.C.K.; Lee, S.T. Evaluation of the Laser Scanner as a Surface Measuring Tool and Its Accuracy Compared with Direct Facial Anthropometric Measurements. Br. J. Plast. Surg. 1995, 48, 551–558. [Google Scholar] [CrossRef]
Name | Abbreviation | Definition |
---|---|---|
Glabella | G | Most prominent midpoint between the eyebrows |
Nasion | N | Deepest point of the nasal bridge |
Exocanthion * | Ex (R or L) | Outer commissure of the eye fissure |
Endocanthion * | En (R or L) | Inner commissure of the eye fissure |
Alare * | Ac (R or L) | Most lateral point on nasal alar contour |
Columella | C | Most anterior point of the nasal septum |
Subnasale | Sn | Midpoint of the base of the nose |
A point | A | Deepest point of the philtrum |
Labiale superius | Ls | Midpoint of the upper vermillion line |
Cheilion * | Ch (R or L) | Most lateral point of the labial commissure |
Pogonion | Pog | Most prominent point of the chin on the sagittal midline |
Landmarks | CBCT | EM3D | Difference | |||||
---|---|---|---|---|---|---|---|---|
Mean Value | SD | Mean Value | SD | Mean Value | SD | p Value | ||
Linear Measurements (mm) | ExR-ExL | 91.869 | 5.09 | 91.845 | 4.65 | 0.023 | 2.50 | 0.986 |
EnR-EnL | 33.751 | 3.03 | 33.355 | 3.17 | 0.395 | 1.34 | 0.642 | |
ChR-ChL | 48.978 | 3.52 | 48.155 | 5.10 | 0.822 | 2.89 | 0.494 | |
AcR-AcL | 33.486 | 3.89 | 33.564 | 3.90 | −0.078 | 1.29 | 0.941 | |
G-Sn | 60.977 | 5.07 | 61.323 | 4.41 | −0.346 | 1.94 | 0.790 | |
Sn-Pog | 48.431 | 6.81 | 49.722 | 5.94 | −1.291 | 2.92 | 0.461 | |
Angle Measurements (°) | N--Pog | 162.667 | 9.85 | 161.137 | 8.44 | 1.529 | 3.72 | 0.543 |
C--Ls | 117.479 | 17.06 | 121.048 | 16.40 | −3.569 | 7.54 | 0.437 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Barone, S.; Antonelli, A.; Salviati, M.; Greco, V.; Bennardo, F.; Becker, K.; Giudice, A.; Simeone, M. Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography. Dent. J. 2024, 12, 342. https://doi.org/10.3390/dj12110342
Barone S, Antonelli A, Salviati M, Greco V, Bennardo F, Becker K, Giudice A, Simeone M. Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography. Dentistry Journal. 2024; 12(11):342. https://doi.org/10.3390/dj12110342
Chicago/Turabian StyleBarone, Selene, Alessandro Antonelli, Marianna Salviati, Vincenzo Greco, Francesco Bennardo, Kathrin Becker, Amerigo Giudice, and Michele Simeone. 2024. "Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography" Dentistry Journal 12, no. 11: 342. https://doi.org/10.3390/dj12110342
APA StyleBarone, S., Antonelli, A., Salviati, M., Greco, V., Bennardo, F., Becker, K., Giudice, A., & Simeone, M. (2024). Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography. Dentistry Journal, 12(11), 342. https://doi.org/10.3390/dj12110342