Next Article in Journal
Impact of Obesity on Atrial Electrophysiological Substrate
Next Article in Special Issue
Comparison of Mid-Term Prognosis in Intermediate-to-Low-Risk Contemporary Population with Guidelines-Oriented Age Cutoff
Previous Article in Journal
First-Trimester Ultrasound Imaging for Prenatal Assessment of the Extended Cardiovascular System Using the Cardiovascular System Sonographic Evaluation Algorithm (CASSEAL)
Previous Article in Special Issue
Surgical Mortality Risk Scores in Transcatheter Aortic Valve Implantation: Is Their Early Predictive Value Still Strong?
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Case Report

Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation?

by
Alessandro Cafaro
1,†,
Francesco Rizzo
2,*,†,
Dionigi Fischetti
1,
Luca Quarta
1,
Marco Mussardo
1,
Alessandro Mandurino-Mirizzi
1,
Antonio Tondo
1,
Marco Matteo Ciccone
2,
Fortunato Iacovelli
2,3 and
Giuseppe Colonna
1
1
Division of Cardiology, “V. Fazzi” Hospital, 73100 Lecce, Italy
2
Division of University Cardiology, Cardiothoracic Department, Policlinico University Hospital, 70124 Bari, Italy
3
Division of Cardiology, “SS. Annunziata” Hospital, 74121 Taranto, Italy
*
Author to whom correspondence should be addressed.
These authors contributed equally to the study and are co-first authors.
J. Cardiovasc. Dev. Dis. 2023, 10(8), 341; https://doi.org/10.3390/jcdd10080341
Submission received: 13 June 2023 / Revised: 19 July 2023 / Accepted: 2 August 2023 / Published: 8 August 2023
(This article belongs to the Special Issue Aortic Stenosis: Diagnosis, Treatment and Management)

Abstract

:
Temporary rapid ventricular pacing (TRVP) is required during transcatheter aortic valve implantation (TAVI) in order to reduce cardiac output and to facilitate balloon aortic valvuloplasty, prosthesis deployment, and post-deployment balloon dilation. The two most frequently used TRVP techniques are right endocardial (RE)-TRVP and retrograde left endocardial temporary rapid ventricular pacing (RLE)-TRVP. The first one could be responsible for cardiac tamponade, one of the most serious procedural complications during TAVI, while the second one could often be unsuccessful. Intracoronary (IC)-TRVP through a coronary guidewire has been described as a safe and efficient procedure that could avoid such complications. We describe two clinical cases in which IC-TRVP has been effectively used during valve-in-valve TAVI with coronary protection via the “chimney technique”, after unsuccessful RLE-TRVP.

1. Case 1

Case 1 is about a 68-year-old female patient scheduled for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) after heart team discussion. She complained of New York Heart Association (NYHA) functional class III in severe aortic prosthetic dysfunction (aortic valve area = 0.8 cm2). A stentless porcine bioprosthesis Freestyle™ (Medtronic, Minneapolis, MN, USA) 21 mm was implanted 12 years before because of severe aortic regurgitation. Cardiovascular risk factors were hypertension, hypercholesterolemia, and former smoking. She also had a history of peripheral arterial disease, previous transient cerebral ischemia and coronary artery disease already treated with coronary artery by-pass grafting, i.e., left internal mammary artery (LIMA) on left anterior descending (LAD) coronary artery and saphenous vein graft on posterior descending artery. A percutaneous coronary intervention (PCI) with rotational atherectomy on left main coronary artery (LMCA) and LAD was recently performed, because of LIMA graft chronic total occlusion. After 1.5 and 1.75 mm burr passages at 160,000 rounds per minute, the mid- and proximal LAD and LMCA heavy calcified stenosis were treated with three sirolimus-eluting stents (3.0 × 18, 3.5 × 33, and 4.0 × 24 mm, respectively) implantation. Intracoronary imaging-guided postdilation until 5.0 mm of the LMCA was performed, with 1 mm strut protrusion into the ascending aorta. A permanent dual chamber pacemaker was implanted one month before TAVI because of sinoatrial block. Other comorbidities were chronic hypochromic microcytic anemia, paroxysmal atrial fibrillation, moderate chronic kidney disease, and anxious-depressive syndrome. Left ventricular ejection fraction (LVEF) was normal. The European System for Cardiac Operative Risk Evaluation (EuroSCORE) II and Society of Thoracic Surgeons predictive risk of mortality (STS-PROM) score were 8.5% and 4%, respectively. Because of heavy calcifications and tortuosity of right ilio-femoral arterial axis, the left side was chosen as main transfemoral access route. A polytetrafluoroethylene-coated, stainless steel 0.035″ wire was inserted into the left ventricle through an Amplatz left (AL) 1 diagnostic catheter. The risk of LMCA occlusion was considered high, due to the valve type, small area of the sinuses of Valsalva, and low valve-to-LMCA height (about 5 mm).
Prophylactic “chimney snorkel” strategy was performed. A 7 French (F) Judkins left 4-curved coronary guiding catheter was advanced till LMCA ostium. A hydrophilic coating over spring coil 0.014″ guidewire was advanced till distal LAD and loaded with a zotarolimus-eluting stent 4.0 × 38 mm that was advanced with mild friction due to previous PCI. The stent length was chosen in order to avoid any further crossing difficulty, to increase radial force with struts overlap, and to ensure a 10–12 mm protrusion enough to overtake both the sinotubular aortic junction and the frame of the intended transcatheter heart valve to implant.
An attempt of retrograde left endocardial temporary rapid ventricular pacing (RLE-TRVP) was unsuccessful. In order to avoid additional vein access and to reduce the potential risk for right ventricular perforation due to right endocardial (RE)-TRVP, an intracoronary (IC)-TRVP was effectively performed (Figure 1): an adaptive alligator clip connecting the guidewire to the pulse generator was used as unipolar cathode, and a skin needle was used as indifferent electrode.
A 20 V maximum unipolar output current erogation was used in order to obtain a pacing of 180 beats per minute (Figure 2). No significant issues on coronary vessels, such as flow retrieve or spasm, occurred.
After the pacing test, a balloon-expandable Edwards Sapien 3™ (Edwards Lifesciences Inc., Irvine, CA, USA) 23 mm valve was directly implanted with no residual significant paravalvular leak and an immediate mean transvalvular pressure gradient of 6 mmHg. Valve positioning was not hampered by LMCA previously implanted stent.
During valve inflation, the coronary guiding catheter was temporarily retrieved, while the new stent was kept in position with sufficient aortic protrusion, ready for immediate implantation (Figure 3A). After valve delivery, a subselective angiography showed reduced LMCA flow due to a displaced surgical bioprosthesis leaflet. The stent was then pulled back, expanded, and postdilated until 20 atmospheres through a 4.5 mm non-compliant balloon (Figure 3B). The “chimney stent” protrusion into the ascending aorta was about 13 mm (Figure 3C), which was close to the estimated implanted valve height of 14 mm. A contemporary “kissing” valve and stent postdilation was not necessary because of an optimal result. Guidewire “stent recrossing test” confirmed the optimal stent placement, just as a chimney parallel to the last implanted valve (Figure 3D), preserving a possible LMCA access for further coronary interventions.
Four days after such a procedure, the patient had been successfully discharged on an oral anticoagulation therapy with apixaban and single antiplatelet therapy with clopidogrel.

2. Case 2

We report the case of an 84-year-old male patient scheduled for ViV-TAVI. Similarly to the former case, he was in NYHA functional class III because of severe aortic prosthetic dysfunction (peak/medium pressure gradients 88/60 mmHg). Cardiovascular risk factors were hypertension, dyslipidemia, overweight, and former smoking; he also referred family history of aortic aneurysm. In 2012, he underwent TAVI with a Direct Flow Medical® (Direct Flow Medical Inc., Santa Rosa, CA, USA) 23 mm bioprosthesis, and soon after, a permanent pacemaker was implanted too. Three years later, the prosthetic valve was affected by thrombosis, successfully treated with unfractionated heparin administration. In August 2020, he underwent a PCI with drug-eluting stent implantation on LAD because of a chronic coronary syndrome. Other comorbidities were anemia and paroxysmal atrial fibrillation; LVEF was normal. EuroSCORE II and STS-PROM score were 5.5% and 3.5%, respectively.
Right arterial access was chosen as main transfemoral route. A pre-shaped stainless steel 0.035″ TAVI-dedicated wire was inserted into the left ventricle through an AL1 diagnostic catheter. A prophylactic “chimney snorkel” strategy was performed. The LMCA ostium was cannulated with a 7 F 4-curved left coronary guiding catheter. As in Case 1, a hydrophilic coating over spring coil 0.014” protection guidewire was inserted into the distal LAD and loaded with a zotarolimus-eluting stent 4.0 × 30 mm. Left femoral arterial access was chosen for insertion of an embolic protection device on the aortic arch.
RLE-TRVP through the 0.035″ wire resulted unsuccessful because of unstable and inconstant stimulation. IC-TRVP was then successfully obtained in the same way as that described in Case 1; there were no significant issues on coronary vessels. After the pacing test, a self-expanding Evolut R™ (Medtronic, Minneapolis, MN, USA) 23 mm bioprosthesis was directly implanted with no significant paravalvular leak and a mean transvalvular gradient of 20 mmHg. After valve deployment, the “chimney stent” was promptly implanted (Figure 4A) and properly postdilated with a 4.5 mm non-compliant balloon, because of significant LMCA flow obstruction due to Direct Flow leaflet dislocation (asterisk in Figure 4B): the stent protrusion into the aorta was about 15 mm (Figure 4C). The “stent recrossing test” with 0.014″ guidewire was successful.
The patient was successfully discharged one week after, with an appropriate apixaban and clopidogrel prescription.

3. Discussion

Along TAVI procedures, TRVP is required in order to reduce cardiac output, facilitating balloon aortic valvuloplasty (BAV), prosthesis deployment, and post-deployment balloon dilation. TRVP failure is known to be more often accompanied by valve malpositioning, and accounts for 11% of valve embolization cases [1]. Furthermore, cardiac tamponade is one of the most serious procedural complications during TAVI, with a reported incidence of 0.2–4.3% [2] and an associated mortality rate of 23.5% [3]. Reports suggest that in more than half of cases (52.9%), cardiac tamponade results from perforation of the right ventricle [2,3,4]. As a safer alternative to RE-TRVP, RLE-TRVP through a supportive 0.035″ wire has already been described along BAV and TAVI [5]. Nevertheless, Faurie et al. reported a rate of unsuccessful RE- and RLE-TRVP of 12.9% and 15.1%, respectively [6]. In our cases, RLE-TRVP was ineffective with all possible electrode settings, maybe because of the wires’ structure. Maneuvers on TAVI delivery system could also interfere with electrode placement on the wire tail.
IC-TRVP, with or without over-the-wire balloon coverage, has been previously described in animal models too [7,8]. In 2022, Heinroth et al. published their successful IC-TRVP experience with a double-wire technique in pig models, using a polytetrafluoroethylene-covered guidewire in the proximal segment of the vessel serving as indifferent anode, and another standard guidewire, advanced into the periphery of the same coronary artery and covered with a coronary balloon, as cathode [9].
Different types of modern coronary guidewires have been successfully tested in order to obtain IC-RTVP without pacing-related complications. The registered pacing resistance was low, and it varied from 12 to 31 ohms depending upon the wire distance from the tip [10].
In humans, this stimulation modality was initially used to detect myocardial viability, and it was first described in 1984 [11]. In six patients, O’Neill demonstrated that the IC-TRVP impedance and pacing thresholds were linked to viable myocardial segments in cardiac magnetic resonance performed before PCI. Pacing was achieved in 40 different coronary tracts; each site of IC stimulation was then compared to the corresponding tributary areas at cardiac magnetic resonance and to the presence, in the same segments, of an epicardial coronary stenosis ≥50%: the evidence of a myocardial scar without any stenosis reducing the coronary lumen more than 50% had significantly different conductance parameters during IC-TRVP [12]. In 2006, Heinroth et al. reported a successful LAD IC-TRVP in 90% of a total of 30 patients undergoing PCI, with low risk of transient coronary spasm [13]. Recently, Mallek et al. reported a case of PCI of a right coronary artery ostial lesion in which IC-TRVP allowed precise stent positioning and implantation [14]. Moreover, the efficacy and safety of the adjunctive IC pacing were tested during rotational atherectomy too [15,16].
Despite its promising data in experimental and clinical settings, this method has not gained general acceptance yet. In fact, to our knowledge, these are the first cases of successful IC-TRVP in TAVI setting. Another peculiar aspect is that our Case 2 is the second reported one of degenerated Direct Flow Medical bioprosthesis treated with a self-expanding transcatheter heart valve implantation, and it is absolutely the first with an Evolut R. In the only other case reported in the literature, a degenerated Direct Flow Medical bioprosthesis was fixed through a ViV implantation of an ALLEGRA™ bioprosthesis (Biosensors International LTD, Wilmington, DE, USA) [17].
Besides being an easy, safe, and stable alternative to RE- and RLE-TRVP, such an IC strategy could avoid the risk of both right ventricular perforation and infectious or hemorrhagic complications at the transfemoral venous access, especially in high-bleeding risk subjects, who represent the majority of TAVI patients.
Finally, IC-TRVP could be furtherly suggested in the case of coronary protection because of the high risk of acute coronary occlusion (CO). Indeed, the latter represents an uncommon but severe complication that occurs during or following <1% of TAVI procedures but carries a 30-day mortality risk of 40-to-50% in published series and registries [18,19]. Among the several risk factors for CO during TAVI, ViV implantation to treat degenerated stentless or stented —but with externally mounted leaflet— bioprostheses, could be considered the most predictive one [18,20,21]. The prophylactic “chimney snorkel” technique has been proven to prevent CO in selected settings [22]. An adequate coronary flow after valve deployment is not a sufficient parameter to decide about stent implantation during coronary protection. Indeed, delayed CO after ViV-TAVI has been reported in cases with high-risk features. In a recently reported series, 27.7% of patients presenting with delayed CO were only protected without stent release because of normal angiographic flow in LMCA after valve expansion, whereas 18.4% received an ostial (non-chimney/non-snorkel) stent [20]. So, during ViV-TAVI at high risk for CO, a low threshold for deploying the coronary stent is recommended. On the other hand, a substantial portion of the “chimney stent” needs to be hung into the ascending aorta, and ideally, the protrusion has to be enough to come above the highest portion of the sealed segment of the transcatheter bioprosthesis.

4. Conclusions

These are, to our knowledge, the first cases of successful IC-TRVP during TAVI. Further studies are needed to confirm the safety and feasibility of this preliminary evidence and maybe to extend IC-TRVP indication to all TAVI patients when coronary protection or PCI are needed, and alternative TRVP methods fail or result in greater risks.

Author Contributions

Conceptualization, A.C.; validation, D.F.; writing—original draft preparation, A.C. and F.R.; writing—review and editing, F.I.; visualization, L.Q., M.M., A.M.-M. and A.T.; supervision, M.M.C. and G.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and approved by the Independent Ethics Committee of ASL Lecce, Italy (study number 158778, and date of approval 27 November 2020).

Informed Consent Statement

Informed consent was obtained from both the subjects involved in the case series.

Data Availability Statement

Data are accessible with the article (raw data are available upon individual request).

Conflicts of Interest

Fortunato Iacovelli directly received speaker fees from General Electric Healthcare; the remaining authors declare no conflicts of interest.

References

  1. Makkar, R.R.; Jilaihawi, H.; Chakravarty, T.; Fontana, G.P.; Kapadia, S.; Babaliaros, V.; Cheng, W.; Thourani, V.H.; Bavaria, J.; Svensson, L.; et al. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: A study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve). J. Am. Coll. Cardiol. 2013, 62, 418–430. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Mollmann, H.; Kim, W.K.; Kempfert, J.; Walther, T.; Hamm, C. Complications of transcatheter aortic valve implantation (TAVI): How to avoid and treat them. Heart 2015, 101, 900–908. [Google Scholar] [CrossRef]
  3. Rezq, A.; Basavarajaiah, S.; Latib, A.; Takagi, K.; Hasegawa, T.; Figini, F.; Cioni, M.; Franco, A.; Montorfano, M.; Chieffo, A.; et al. Incidence, management, and outcomes of cardiac tamponade during transcatheter aortic valve implantation: A single-center study. JACC Cardiovasc. Interv. 2012, 5, 1264–1272. [Google Scholar] [CrossRef] [Green Version]
  4. Chiam, P.T.; Ewe, S.H. An update on complications associated with transcatheter aortic valve implantation: Stroke, paravalvular leak, atrioventricular block and perforation. Future Cardiol. 2013, 9, 733–747. [Google Scholar] [CrossRef]
  5. Roland, H.S.; James, C.; Maureen, D.; Jessica, P.; Andrea, N.; Andrew, H.; Uday, T.; de Belder, A.; Hildick-Smith, D. Rapid pacing using the 0.035-in. Retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty. Catheter. Cardiovasc. Interv. 2017, 89, 783–786. [Google Scholar] [CrossRef]
  6. Faurie, B.; Souteyrand, G.; Staat, P.; Godin, M.; Caussin, C.; Van Belle, E.; Mangin, L.; Meyer, P.; Dumonteil, N.; Abdellaoui, M.; et al. EASY TAVI Investigators. Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement. JACC Cardiovasc. Interv. 2019, 12, 2449–2459. [Google Scholar] [CrossRef]
  7. Heinroth, K.M.; Carter, J.M.; Buerke, M.; Mahnkopf, D.; Werdan, K.; Prondzinsky, R. Optimizing of transcoronary pacing in a porcine model. J. Invasive Cardiol. 2009, 21, 634–638. [Google Scholar]
  8. Heinroth, K.M.; Unverzagt, S.; Mahnkopf, D.; Prondzinsky, R. Transcoronary pacing Reliability during myocardial ischemia and after implantation of a coronary stent. Med. Klin. Intensivmed. Notfmed. 2020, 115, 120–124. [Google Scholar] [CrossRef]
  9. Heinroth, K.M.; Unverzagt, S.; Mahnkopf, D.; Horenburg, C.; Melnyk, H.; Sedding, D.; Prondzinsky, R. Transcoronary pacing in an animal model: Second coated guidewire versus cutaneous patch as indifferent electrodes. Med. Klin. Intensivmed. Notfmed. 2022, 117, 227–234. [Google Scholar] [CrossRef]
  10. Parakh, N.; Asotra, S.; Singh, S.; Ramakrishnan, S.; Karthikeyan, G.; Seth, S.; Bhargava, B. Transcoronary pacing: Are the modern wires effective? Indian. Heart, J. 2009, 61, 160–162. [Google Scholar]
  11. Meier, B.; Rutishauser, W. Coronary pacing during percutaneous transluminal coronary angioplasty. Circulation 1985, 71, 557–561. [Google Scholar] [CrossRef] [Green Version]
  12. O’Neill, J.; Hogarth, A.J.; Pearson, I.; Law, H.; Bowes, R.; Kidambi, A.; Wheatcroft, S.; Sivananthan, U.M.; Tayebjee, M.H. Transcoronary pacing to asses myocardial viability prior to percutaneous coronary intervention: Pilot study to assess feasibility. Catheter. Cardiovasc. Interv. 2018, 92, 269–273. [Google Scholar] [CrossRef]
  13. Heinroth, K.M.; Stabenow, I.; Moldenhauer, I.; Unverzagt, S.; Buerke, M.; Werdan, K.; Prondzinsky, R. Temporary transcoronary pacing by coated guidewires. Clin. Res. Cardiol. 2006, 95, 206–211. [Google Scholar] [CrossRef]
  14. Mallek, K.; Dalton, R.T.; Pareek, N.; Dworakowski, R. Rapid Transcoronary Pacing to Facilitate Ostial Stent Placement. JACC Cardiovasc. Interv. 2021, 14, e111–e112. [Google Scholar] [CrossRef]
  15. Kusumoto, H.; Ishibuchi, K.; Hasegawa, K.; Otsuji, S. Trans-coronary pacing via Rota wire prevents bradycardia during rotational atherectomy: A case report. Eur. Heart J. Case Rep. 2022, 6, ytac013. [Google Scholar] [CrossRef]
  16. Iqbal, M.B.; Robinson, S.D.; Nadra, I.J.; Das, D.; van Zyl, M.; Sikkel, M.B.; Della Siega, A. The Efficacy and Safety of an Adjunctive Transcoronary Pacing Strategy During Rotational Atherectomy: ROTA-PACE Study. JACC Cardiovasc. Interv. 2023. [Google Scholar] [CrossRef]
  17. Ancona, M.B.; Visco, E.; Khawaja, S.; Romano, V.; Moroni, F.; Ferri, L.; Bellini, B.; Beneduce, A.; Ancona, F.; Agricola, E.; et al. Valve-in-Valve With Allegra Implantation in Failed Direct Flow Transcatheter Heart Valve. JACC Cardiovasc. Interv. 2020, 13, e19–e20. [Google Scholar] [CrossRef]
  18. Arai, T.; Lefèvre, T.; Hovasse, T.; Garot, P.; Benamer, H.; Unterseeh, T.; Roy, A.K.; Romano, M.; Hayashida, K.; Watanabe, Y.; et al. Incidence and predictors of coronary obstruction following transcatheter aortic valve implantation in the real world. Catheter. Cardiovasc. Interv. 2017, 90, 1192–1197. [Google Scholar] [CrossRef]
  19. Ribeiro, H.B.; Nombela-Franco, L.; Urena, M.; Mok, M.; Pasian, S.; Doyle, D.; DeLarochellière, R.; Côté, M.; Laflamme, L.; DeLarochellière, H.; et al. Coronary obstruction following transcatheter aortic valve implantation: A systematic review. JACC Cardiovasc. Interv. 2013, 6, 452–461. [Google Scholar] [CrossRef] [Green Version]
  20. Jabbour, R.J.; Tanaka, A.; Finkelstein, A.; Mack, M.; Tamburino, C.; Van Mieghem, N.; de Backer, O.; Testa, L.; Gatto, P.; Purita, P.; et al. Delayed coronary obstruction after transcatheter aortic valve replacement. J. Am. Coll. Cardiol. 2018, 71, 1513–1524. [Google Scholar] [CrossRef]
  21. Ribeiro, H.B.; Rodés-Cabau, J.; Blanke, P.; Leipsic, J.; Kwan Park, J.; Bapat, V.; Makkar, R.; Simonato, M.; Barbanti, M.; Schofer, J.; et al. Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter1 aortic valve replacement for degenerative bio-prosthetic surgical valves: Insights from the VIVID registry. Eur. Heart. J. 2017, 39, 687–695. [Google Scholar] [CrossRef] [Green Version]
  22. Fetahovic, T.; Hayman, S.; Cox, S.; Cole, C.; Rafter, T.; Camuglia, A. The Prophylactic Chimney Snorkel Technique for the Prevention of Acute Coronary Occlusion in High Risk for Coronary Obstruction Transcatheter Aortic Valve Replacement/Implantation Cases. Heart Lung Circ. 2019, 28, e126–e130. [Google Scholar] [CrossRef]
Figure 1. Adaptive alligator clip connecting the guidewire to the pulse generator used as unipolar cathode and the skin needle used as indifferent electrode.
Figure 1. Adaptive alligator clip connecting the guidewire to the pulse generator used as unipolar cathode and the skin needle used as indifferent electrode.
Jcdd 10 00341 g001
Figure 2. Left pressure wave flattening, via effective IC-TRVP.
Figure 2. Left pressure wave flattening, via effective IC-TRVP.
Jcdd 10 00341 g002
Figure 3. “Chimney stent” (asterisk) positioning in LMCA and previously implanted LMCA edge aortic protrusion (arrow) immediately before valve implantation (A); “Chimney stent” protrusion into aorta (B) and postdilation (C); final left coronary angiography after Sapien 3 valve implantation (D).
Figure 3. “Chimney stent” (asterisk) positioning in LMCA and previously implanted LMCA edge aortic protrusion (arrow) immediately before valve implantation (A); “Chimney stent” protrusion into aorta (B) and postdilation (C); final left coronary angiography after Sapien 3 valve implantation (D).
Jcdd 10 00341 g003
Figure 4. LMCA stent implantation (A); subselective coronary angiography after stent implantation with Direct Flow leaflet (asterisk) near LMCA ostium after Evolut R release (B); stent protrusion into the aorta (C).
Figure 4. LMCA stent implantation (A); subselective coronary angiography after stent implantation with Direct Flow leaflet (asterisk) near LMCA ostium after Evolut R release (B); stent protrusion into the aorta (C).
Jcdd 10 00341 g004
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Cafaro, A.; Rizzo, F.; Fischetti, D.; Quarta, L.; Mussardo, M.; Mandurino-Mirizzi, A.; Tondo, A.; Ciccone, M.M.; Iacovelli, F.; Colonna, G. Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation? J. Cardiovasc. Dev. Dis. 2023, 10, 341. https://doi.org/10.3390/jcdd10080341

AMA Style

Cafaro A, Rizzo F, Fischetti D, Quarta L, Mussardo M, Mandurino-Mirizzi A, Tondo A, Ciccone MM, Iacovelli F, Colonna G. Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation? Journal of Cardiovascular Development and Disease. 2023; 10(8):341. https://doi.org/10.3390/jcdd10080341

Chicago/Turabian Style

Cafaro, Alessandro, Francesco Rizzo, Dionigi Fischetti, Luca Quarta, Marco Mussardo, Alessandro Mandurino-Mirizzi, Antonio Tondo, Marco Matteo Ciccone, Fortunato Iacovelli, and Giuseppe Colonna. 2023. "Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation?" Journal of Cardiovascular Development and Disease 10, no. 8: 341. https://doi.org/10.3390/jcdd10080341

APA Style

Cafaro, A., Rizzo, F., Fischetti, D., Quarta, L., Mussardo, M., Mandurino-Mirizzi, A., Tondo, A., Ciccone, M. M., Iacovelli, F., & Colonna, G. (2023). Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation? Journal of Cardiovascular Development and Disease, 10(8), 341. https://doi.org/10.3390/jcdd10080341

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop