1. Introduction
Many monographs and textbooks, such as [
1,
2,
3,
4], articles, reviews in scientific and specialized journals, in particular [
5,
6,
7,
8], which contain extensive information on this area, are devoted to the physics of vibrations and methods of their measurement. There are international and national standards for measuring vibration parameters and industrial measuring instruments. The main vibration parameters are amplitude, speed, acceleration, and frequency. Measuring the deformation of machine elements, mechanisms, and building structures under the influence of vibrations is also an important task, but such a task requires other technical solutions, in particular, the use of strain gauge [
9,
10] or fiber Bragg gratings (FBG) as a vibration sensor.
Fiber Bragg gratings are currently widely used to work in conditions of strong electromagnetic interference caused by pulsed magnetic fields, powerful ultrahigh frequency radiation, radio transmitting devices, and other sources of interference. The demand for FBG sensors is due to their high sensitivity, small dimensions, long service life, resistance to aggressive environments, explosion safety, insensitivity to electromagnetic interference, and the possibility of multiplexing. Currently, FBG sensors are widely used in engineering to measure temperature, deformation parameters, as well as for other applications.
The principle of operation of FBG sensors is based on measuring changes in the resonant wavelength of the grating or the power of the reflected radiation due to changes in the resonant wavelength of the grating and is described in detail in literary reviews and monographs, in particular, in [
11,
12,
13,
14,
15,
16,
17,
18,
19,
20,
21,
22].
To measure temperature, as well as slow deformations, interrogators [
11,
12,
13] are successfully used in conjunction with FBG, in particular, using wavelength scanning, for example, using linear CCD array. For slow processes, the problem of determining the dependence of deformation on time is not related to the measurement speed of the resonant frequencies of the FBG, but to the accuracy of measurements and the interpretation of the resulting dependencies. In a uni-axial approximation, i.e., assuming that there is only stretching or compression of the FBG along one axis at a constant temperature, such a task is not seriously difficult within the technical capabilities of the equipment used. In more detail analysis of peak tracking techniques for FBG sensors is given in the review [
12]. However, the practical use of strain sensors based on FBG for various devices may have its own specifics. The theoretical foundations and experience of creating such systems are presented in reviews and scientific articles, for example [
11,
12,
13,
14,
15,
16,
17,
19,
20,
21,
22].
It is necessary to use other methods, such as those described in [
23,
24,
25,
26,
27,
28,
29,
30,
31,
32,
33] to register signals with short pulse exposure. However, such methods are difficult to adapt for vibration measurement. So, in [
24,
25], all measurements were carried our at the same wavelength, which limited the measurement range of the strain value
. The principle of operation of some devices is based on a change in the reflective properties of the FBG when it is destroyed by a propagating detonation wave, which cannot be used to measure the parameters of continuous vibration. The basic principles and methods for measuring vibration parameters using fiber Bragg gratings are summarized in the reviews [
22,
34,
35,
36,
37,
38,
39,
40], and are also presented in scientific articles, for example, [
41,
42,
43].
Measuring the parameters of high-frequency vibrations using FBG is a certain difficulty, since it is necessary to provide the technical possibility of registering such signals, possibly over a wide range of changes in the magnitude of strain , as well as determining the parameters using obtained data. If it is possible to measure the power p reflected by FBG radiation simultaneously at several wavelengths , the task of determining vibration parameters is to restore the dependence of the strain (relative deformation) value on time t according to several dependencies , where m is the number of the photodetector channel with a central filtration wavelength . Technically, to implement the method, it is necessary to use either a source with a wide spectrum of radiation or several narrow-band sources simultaneously, with a system of several photodetectors registering radiation at specified wavelengths and operating simultaneously, such as, for example, a WDM (wavelength-division multiplexing) systems. It is necessary to know the type of spectral dependence of the FBG reflection on which the calculation algorithm of depends to determine the value of . Dependencies can also be called signals that require digital processing to obtain vibration parameters. The frequency range of measurement can extend from zero to hundreds of megahertz and above, and the maximum measured magnitude is determined by the number of channels m. The frequency range of measurement of using the technique discussed below is limited by the condition of uniformity of stretching or compression of the FBG along the entire length assumed in the calculations. If the mechanical effect is such that the specified condition is violated, the model used requires taking into account the heterogeneity of the impact on the FBG.
For stationary vibrations, i.e., vibrations whose parameters do not change over time, various methods and devices can be used. In this paper, we propose the use of a technique based on a sequential change in the wavelength of an optical radiation source, the preservation of FBG signals at different wavelengths recorded at different times, and the determination of vibration parameters based on such a set of signals.
The physical and mathematical basis of the proposed methods, consisting of numerical simulation and theoretical harmonic analysis of signals, is presented below. The description of the experimental implementation of the method and the results confirming the main patterns of the theoretical consideration are also presented.
2. Numerical Simulation of Signals for a Fiber Bragg Grating with Trapezoidal Reflection Spectrum
The numerical simulation task consists of modeling the initial dependence of deformation on time with specified parameters, calculating the signal reflected from the FBG at various wavelengths, adding a given noise level to the calculated signals, and restoring the dependence of deformation on time based on the data obtained.
The simulation of
was performed using recurrent formulas [
44] for a stationary sequence of numbers
, where
n is the number of the sequence element, with a normal distribution, unit variance, and exponential auto-correlation function
C of the form:
where
is the attenuation decrement,
is the characteristic cyclic frequency, and
D is the proportionality coefficient depending on the amplitude of vibrations. Accordingly, the sequence of relative strain values is calculated using the formula:
where
is the coefficient determining the vibration amplitude. It is enough to specify only one coefficient
and set
to model the
. Since this paper considered a time-dependent process, the elements of the sequence
could be represented as the amount of strain at discrete time points
:
.
Let us consider the simplest model describing the normalized dependence (
) of the power of reflected radiation by a fiber Bragg grating on the wavelength of radiation
in the operating wavelength range in the following form (
Figure 1) by analogy with the dependence presented in [
45]:
where (
Figure 1)
is the wavelength corresponding to the beginning of the inclined
dependence,
is the spectral width of the inclined section of the
,
is the proportionality coefficient (
),
is the resonant wavelength of the FBG, and
is the wavelength corresponding to the end of the inclined section (
). If the transmission spectrum width of the photodetector filter (or the spectrum width of the radiation source, if, for example, several semiconductor lasers are used) is significantly less than the value
, then the
dependence is actually the dependence of the power
p of the radiation reflected by the FBG, normalized to the maximum value, on the wavelength
.
It is known that the displacement of the resonant wavelength FBG under tension is proportional to the magnitude of the relative FBG deformation (i.e., FBG strain)
. We assume that at the deformations considered below—uni-axial tension or compression—the shape of the
spectral dependence does not change, i.e., it takes place as follows:
where
is the proportionality coefficient (
/nm at
nm, and
/nm at
nm). That is, when the FBG is stretched, the
dependence shifts towards longer wavelengths (in
Figure 1—to the right along the 0× axis).
Let us choose the wavelengths of radiation
at which the dependencies of the reflected radiation power on time will be most characteristic for considering the basic patterns. At
, let
be such that
,
, and
, respectively,
, …,
,
,
, …,
, where
is an integer. Then, Formula (3) can also be represented as:
where
is the central wavelength of the falling section, at which the equality
is satisfied, i.e.,
. The dependence
is given in the form of a series of numbers
generated according to the above algorithm in accordance with Formulas (1) and (2).
For small deformations, i.e., if the inequality
and
always holds:
Thus, with a small deformation, no special algorithms need to be used to determine the dependence of ; it is enough to perform a measurement at one wavelength (), since the magnitude of is proportional to the amplitude of the reflected FBG signal. The linear elongation of the FBG leads to a linear increase in the reflected FBG power p until p reaches its maximum value (i.e., ). When FBG is compressed, the power p is reduced to zero (i.e., ).
If the vibration amplitude is such that
, measurements must be performed simultaneously at several wavelengths. Taking into account that the measurement range at one wavelength is
, it is advisable to select the measurement wavelengths with an offset by the specified amount
, as indicated above. Then, the magnitude of the strain
can be determined from the sections of dependencies
specified at points
, at which the dependence has a non-zero and non-equal-to-one value, as well as assuming the same spectral sensitivity:
The described technique and Formula (7) assume the idealized dependence . When processing experimental data, it is necessary to take into account both the noise level and the deviation of the dependence from 1 in the range , for example, excluding points near 0 and 1 from consideration and, if necessary, using wavelength offset less than .
As an example, the modeling of signals recorded at various wavelengths with the following parameters was performed:
was a sequence of numbers with normal distribution, whose sequence parameters were given by Formulas (1) and (2):
,
,
, at
nm,
per nm,
= 0.2 nm,
. A random noise of 1% was added to the signal calculated by Formula (2). The specific sampling value
does not matter in this case, and all time dependencies are given later in the article as dependencies on the reference number. An example of the simulated initial dependence
obtained by interpolating the values of
is shown in
Figure 2a. The dependencies of the normalized power
for seven wavelengths are shown in
Figure 3 and
Figure 4.
Let us consider the entity and basic patterns of the dependencies shown in
Figure 3 and
Figure 4. On the first flat section
for
, extending approximately from number 35 to number 100, there is a stretching of the FBG, leading to
. Moreover, at wavelengths
,
, and
,
occurs due to
(
Figure 4). At large wavelengths
,
, and
, the value of
in this range
n sometimes reaches 0, and at
it becomes different from 0 only at the moments of the largest stretching of the FBG (
Figure 3). The range of
n is from 110 to 160 (
Figure 3 and
Figure 4, curves “a”) corresponds to the compression of the FBG at which
. At wavelengths
,
, and
, the value of
in this range sometimes reaches 1, and at
, it becomes different from 1 only at the moments of the greatest compression of the FBG (
Figure 4).
The dependence
, reconstructed from the seven dependencies
at different wavelengths, is shown in
Figure 2b. As follows from
Figure 2, the restored dependence
almost coincides with the original dependence
even with the noise level of 1% introduced.
3. Numerical Simulation of Signals for a Fiber Bragg Grating with Gaussian Reflection Spectrum
The fundamental difference between the signals of the FBG with a Gaussian reflection spectrum from those previously considered is due to the fact that, unlike the trapezoidal spectrum, any normalized value not equal to one of the reflected power always corresponds to two different values of strain of the FBG, as well as the fact that the signal can be zero only, not equal to zero, and one, as for trapezoidal spectrum, at a deformation of the FBG outside the range of Gaussian reflection.
The waveform of the pulse deformation in the FBG in the case of a Gaussian spectrum is considered in [
24,
25]. It follows that the type of pulse signal, and even more so its parameters, depend on the difference in the wavelengths of the radiation source and the resonant wavelength of the reflection of the FBG.
The main properties of the vibration signal reflected from the FBG can be explained based on the analysis of signals with harmonic deformations of the FBG at various operating points (i.e., at different wavelength differences). Let
where
is the magnitude of the strain of the FBG at the vibration,
is the cyclic deformation frequency, and
t is the time. Then,
where
is the proportionality coefficient,
is the equivalent half–width of the reflection spectrum of the FBG [
24,
25],
is the difference between the wavelengths of the radiation source and the resonant wavelength of the FBG at zero deformation (i.e., in the absence of stretching or compression). Let us further consider the normalized functions
, i.e., assuming
.
First, let us consider the case of a weak vibration (
). An example of the calculated dependencies of
at four characteristic points, at the top of the spectrum (at
, i.e., at
), on the slope of the spectrum (
,
), and in the region of small values of the reflected power (
), is shown in
Figure 5. It follows from the obtained dependencies that at the top of the spectrum the reflected signal (
Figure 5, dependence 1) has a doubled frequency compared to the deformation frequency and a relatively small amplitude. The signals have a shape close to sinusoidal but different amplitudes (
Figure 5, dependencies 2 and 3) on the slope of the spectral dependence at the point of maximum sensitivity (
) and slightly lower. The signal has a shape similar to the above dependencies but a significantly lower amplitude at
. The phase of the reflected signal on a slope with
coincides with the phase of strain oscillations, and on a slope with
, it has the opposite phase.
A characteristic of this phenomenon is the dependence of the harmonic coefficient of the signal on the position of the working point (i.e., the difference
). The harmonic coefficients were calculated using formulas similar to the calculation of nonlinear distortion coefficients:
where
n is the harmonic number in Formulas (10)–(12).
For the considered examples, the values of the fourth and higher harmonics were neglected. Trends and took place when and .
The example of the calculated dependencies is shown in
Figure 6.
For a strong periodic deformation, i.e.,
, the shape of the reflected FBG signal is close to Gaussian with an average period equal to the half-life of the FBG deformation (
Figure 7).
As follows from the data obtained (
Figure 7), when compressing the FBG (the interval from
to
in
Figure 7) first, the pulse appears at
, then at
and
. Dependence 1 (
Figure 7) corresponds to the absence of deformation of the FBG, which occurs at the oscillation phase
equal to
. When the FBG is compressed, the specified pulse is the last of the specified ones. The pulse sequence is reversed when stretching the FBG (the interval from
to
in
Figure 7). The greater the value of
, the shorter the duration of Gaussian-like pulses. The time interval between pulses is always equal to the value
at
, greater than
in the range of transition from compression to tension at
, and less than
in the range of transition from tension to compression (not shown in
Figure 7).
Based on the studied patterns, it can be concluded that the method of signal reconstruction based on time dependencies measured simultaneously at several wavelengths requires changes compared to the previously considered method for the trapezoidal spectral dependence of the FBG. First, it is advisable to exclude measurements for (i.e., for ) in order to avoid the difficulty of unambiguously determining deformation by choosing an even non-zero number of wavelengths, for example, as , , , …, . The number of wavelengths at which the measurement is performed (and, accordingly, the number of photodetectors) should be such that the radiation reflected from the FBG during the measurement process is always recorded by some photodetector.
An example of the simulated dependencies of the power, simultaneously measured at different wavelengths, is shown in
Figure 8. The example illustrates the patterns of signals described above. The signal was restored using dependencies
,
, …,
,
, starting from the dependence
according to the following algorithm. We assumed that the change in the wavelength of the FBG under the action of vibrations was in the range of the possibility of registering a signal by photodetectors at these wavelengths or, at least, at the initial section of the function
. Let us assume that the reliably recorded power value in each channel, taking into account noise, is, for example, in the range
. Starting from
for each point in the sequence
power values, we checked the fulfillment of the condition:
for all channels
m, starting from
(i.e.,
. If the condition (13) was fulfilled, then the value of the strain was calculated by the formula:
For the remaining wavelengths of
, the value of
was not calculated. Random noise in the amount of 1% of the maximum value was added to the
signals of each channel. An example of the initial waveform of strain (
) of the FBG during vibration and the resulting waveform restoration (
) using eight wavelengths is shown in
Figure 9. As follows from
Figure 9, there was a good coincidence of the dependencies
and
. Note also that in the presented example, a fragment of the dependence
was specially selected for which, in the range
n from 1773 to 1793, the value of
exceeded 750
, which made it impossible to accurately restore the signal in this
n range. Therefore, if necessary, in similar cases, for example, to identify the maximum values of stretching or compression of the FBG during vibration, it is necessary to add another measurement channel at the wavelength of
for which
.
Thus, the sequence of actions for determining the dependence of is as follows. Starting from the first element () of the samples, values are scanned by the index m, starting from the first or last value of m. In the above example, processing was performed from to . Condition (13) is checked for each index m. If the condition is met, the value is calculated for this sequence of (i.e., for indices m and n) using Formula (14). Further scanning by the index m is interrupted, the verification of condition (13) is started anew for the next number of the sequence element () from the first or last value of m. The calculation is completed when the last element of the samples is reached.
Taking into account the ranges for determining the amount of deformation overlap, the accuracy of the signal recovery can be improved by choosing a range in which this value of deformation is calculated with greater accuracy. It can be assumed that the accuracy of the determination of
is proportional to the modulus of the derivative of the dependence
, determined by Formula (9), with respect to
. At
, the maximum is reached at
[
24,
25], and in the case under consideration, it is advisable to choose an array
in which the modulus of the derivative
at this point (
n) is greater.
4. Determination of Vibration Parameters by Samples with Successive Changes in the Wavelength
In many cases, it is not technically possible to measure the power of the reflected radiation simultaneously at several wavelengths. If vibration is a stationary process, i.e., the vibration parameters are constant at least during the measurement, then, in that case, the density distribution of the strain can be determined from samples of signals measured sequentially at different wavelengths at different times. Technically, such measurement can be performed using a semiconductor laser mounted on a Peltier element, which allows the temperature of the laser heterojunction to be changed, as well as the wavelength of the radiation. The result of such measurement is m fragments of power versus time, measured sequentially at m wavelengths. Naturally, it is impossible to restore the full dependence of in this case, but the density distribution of calculated from m fragments will correspond to the distribution density of the full .
In contrast to the used signal reconstruction technique described earlier for the Gaussian spectral dependence of the FBG reflection, in this case, it is impossible to use the exclusion of samples at other wavelengths after determining
at any point in one of the samples. Therefore, it is necessary to exclude in another way the influence of overlapping areas of the
dependencies on the result of calculating the probabilistic characteristics of the process. This is achieved by selecting the signal levels in each channel, within which the value of
is determined; thus, the end of one range in one channel is the beginning of the measurement range in another channel (for example, in channels
and
). Let
,
be the lower and upper limits of the range of determination of
. The wavelength shift between the channels is equal to the value
when:
If the upper level (the upper limit of the measurement range in channel m) is set as 0.95 of the maximum value, then when the wavelengths are shifted by the value of , the corresponding lower level in the adjacent channel () will be approximately equal to 0.22218. Accordingly, the calculation range of used to calculate the probabilistic characteristics will be from 0.22218 to 0.95.
The method was verified by numerical modeling for the Gaussian distribution obtained using the previously described technique with the Gaussian FBG reflection spectrum. The simulation result is described below.
5. Simulation of Determination of the Probability Density of the Strain Distribution with a Sequential Change in the Wavelength of the Radiation
If there is no technical possibility of simultaneous measurement of the reflected radiation at different wavelengths, then for a stationary process (i.e., with constant statistical parameters), the probability density of the strain distribution can be determined by a sequential change in the wavelength of the source radiation. Technically, this can be accomplished either by changing the wavelength of the laser or using a tunable spectral filter for the reflected FBG radiation at a broadband radiation source. Since in this case, at each wavelength, the dependencies are obtained sequentially at different points in time, it is impossible to restore the dependence . However, due to the stationarity of the random process , it is sufficient to determine the probability density of the distribution in the operating range of the measured values for the dependencies at each wavelength, so that the measurement ranges do not overlap.
This technique was tested by numerical simulation for the case of reflected FBG radiation with a Gaussian spectrum and the Gaussian distribution . Using the method described earlier and Formula (14), 10 arrays of 4096 numbers each of values with the offset from to were generated. Then, the corresponding dependencies of were calculated at different wavelengths with a shift by the value of . The coefficient was set to 300, was nm/, and was 0.2 nm. For each array, the values of corresponding to the elements of p were determined. A random noise of 1% of the maximum value of p (in this case – 1) was artificially added to all the obtained values of the elements. Further, similar to the above-described technique for the case of the Gaussian reflection spectrum of the FBG, the values of in each array were determined. The obtained values of were combined into one array and, using a standard statistical data processing program, a histogram of the distribution of was obtained. The difference in the calculated histogram of the distribution obtained from 10 fragments and the histogram of the initial dependence was no more than 5%. The average shape of the histogram approached the Gaussian one, and the existing difference was due to a statistical error when the numerical experiment was repeated many times. The result can be considered expected, since it was initially assumed that the random process was stationary. Therefore, an example of the resulting histogram is not provided.
6. Experiment
The experimental study was performed on a single-mode optical fiber with a fiber Bragg grating with a central wavelength at room temperature of 1310 nm, a reflection spectrum width of 0.0777 nm (
nm), an FBG length of 15 mm, with a maximum reflection coefficient of 90%. The scheme of the experimental installation is shown in
Figure 10. The optical fiber 1 with the fiber Bragg grating was fixed in the upright position on the special mechanical construction 2 by a holder 3. The electric motor 5 with an eccentricity was attached to the optical fiber from below. The optical fiber was passed through two holes 4 in the mounting brackets between FBG and the electric motor. The diameter of the holes 4 exceeded the outer diameter of the fiber sheath by about 500 μm. The distance between the brackets was approximately 0.5 m, and that between the FBG and the electric motor was −1 m. The installation design made it possible to practically eliminate the bends of the FBG during vibration, which allowed us to assume the vibration of the FBG to be uni-axial.
The DFB-type semiconductor laser 7 with a wavelength of 1310 nm, a half-width of the radiation spectrum equal to 0.015 nm, and a temperature coefficient of wavelength variation of 0.071 nm/°C was used as a radiation source. The laser was mounted on the Peltier element, which made it possible to change the temperature of the laser heterojunction within ±15 °C by changing the amplitude and direction of the current flowing through the element, using the power supply 11. The possible wavelength adjustment exceeded 2 nm. The accuracy of the laser temperature measurement was approximately 0.1 °C. The equivalent value of the half-width of the spectrum used in the calculations was set to 0.05 nm. The change in the laser temperature, leading to the specified value of the wavelength offset by the value , was 0.7 °C.
The dependencies of
were determined using standard passive fiber-optic components—photodetector 9 and splitter 6 with a 50%/50% division coefficient according to the standard scheme in [
25] for measurements of the power of radiation reflected from the FBG. The signal from the photodetector module was transmitted to the analog-to-digital converter and stored in the memory of a personal computer 10. The sampling frequency was 100 kHz, the arrays contained approximately
samples each; however, only 4096 array elements with the specified sampling interval were used to calculate the distribution parameters. The optical fiber with the fiber Bragg grating was fixed in the upright position. An electric motor with an eccentricity was mounted at the bottom of the fiber with the FBG, creating uni-axial vibrations in the FBG, the shape of which could be assumed to be sinusoidal. The resonant wavelength of the fiber Bragg grating, elongated by the weight of the vibrating device in the absence of vibration, was taken as the initial wavelength
.
The
dependencies obtained at different laser temperatures with a step of 0.1 °C were preserved. An example of the obtained dependencies of
for a relatively small deformation is shown in
Figure 11.
Figure 11a corresponds to the case of the location of the working point near the sensitivity maximum, b—at the maximum, i.e., approximately at
, c—near the maximum of the reflection spectrum of the FBG. The characteristic properties of the obtained dependencies corresponded to the results obtained by numerical simulation for harmonic oscillations (
Figure 5). The dependence
in
Figure 11a had a shape close to sinusoidal with a period of approximately 46 ms, which corresponds to a frequency of 22 Hz. The dependence
shown in
Figure 11c was due to the fact that the resonant wavelength of the FBG, which varied with the vibration, reached the wavelength of radiation of the source and exceeded it for some time. This led to a noticeable appearance of the second harmonic of the vibration signal.
Figure 11b corresponds to the case
in which the signal
had a doubled vibration frequency of approximately 44 Hz. The estimated value of the vibration magnitude, as shown in
Figure 11a, was approximately
. The spectral density of the
signals shown in
Figure 11 were calculated (
Figure 12). It followed from the obtained dependencies (
Figure 12) that in the first case (dependence a,
Figure 11), the first harmonic of the signal was dominant. The maximum spectral density of the second (
) and third (
) harmonics was approximately 11 and 14 times less than the first (
), respectively. In the second case (dependence b,
Figure 11), the second harmonic dominated, in which
and
were 1.5 and 3 times smaller than
. In the third case (dependence c,
Figure 11),
and
were 2 and 16 times smaller than
. That is, the experimental data obtained confirmed the identified characteristic features of the signals generated by the radiation reflected from the fiber Bragg grating during linear oscillations.
Since in this case, the change in
during vibration occurred in the measurement range of
at one wavelength, one dependence
was sufficient to calculate the probability density of the distribution of
using
Figure 11a. Therefore, an example of the histogram of the distribution of
is not given in the work.
To increase the magnitude of the strain fluctuations, the flexible rods were attached to the rotating part of the device, in contact with the fixed elements of the experimental installation during rotation. This allowed us to increase the magnitude of
by more than two times, as well as to make the shape of the oscillations more complex. Similarly to the previous case, the dependencies
of the power of the radiation reflected from the FBG at different temperatures of the semiconductor laser (respectively, at different wavelengths) were measured. The histogram of the distribution of
was calculated using the method described above for the case of four wavelengths (
Figure 13). The resulting distribution of
was asymmetric, which was explained by the appearance of a bending of the fiber, which prevented the compression of the FBG when the zero value of
was reached relative to the free (i.e., unloaded) state of the FBG during vibration.
7. Discussion
This paper considered a uni-axial deformation—a stretching or compression of the FBG. However, in most practical cases, in addition to stretching, there is a bending of the optical fiber with the FBG. A detailed consideration of the effect of deformation fields on the reflection spectra of Bragg gratings is given in [
46,
47], which can be taken into account in the calculations. However, the values of
calculated according to the above method can be regarded as equivalent values of relative deformation.
Obviously, for strain measurements, it is necessary to ensure the stability of the wavelengths at which measurements are made. If a broadband radiation source, a spectral filter, and photodetector modules are used, which are constantly tuned to the same wavelength in the optical measurement scheme, then it is assumed that such a device ensures the stability of measurements. However, with a wide spectrum of the radiation source, the power coming from the filtered spectral ranges is significantly less than when using a narrow-band laser. Consequently, the measured dependencies have the worst signal-to-noise ratio, which has the strongest effect in the case of a wide frequency range of recorded signals. The problem of using standard components of WDM systems (semiconductor lasers, multiplexers, demultiplexers, and photodetectors) is the difficulty of matching the wavelengths of WDM elements with the reflection spectrum of the Bragg fiber lattice, since the latter depends on temperature. An even more difficult case for the use of WDM components are FBGs attached to or mounted in any structural elements, since the temperature coefficient of expansion in this case may be significantly higher than the FBG itself, which may require a significant change in the calculation algorithm.
When using a semiconductor laser, whose wavelength tuning is achieved by changing the temperature of the heterojunction, it is relevant to determine the requirement for the maximum allowable deviation
of the wavelength from the required one. This is most relevant for a method using a sequential change in the laser wavelength. If we assume that the condition
must be fulfilled, then in order to fulfill this condition, it is necessary to have:
where
is the maximum permissible temperature deviation from the required value during the measurement process, and
is the temperature coefficient of the laser wavelength change. As indicated above, for typical parameters of FBGs and DFB lasers, the estimated value is 0.1 °C, which is easily achievable.
However, if the temperature measurement uses a sensor built into the semiconductor laser housing (for example, a thermistor), and even more so if the sensor is mounted outside the laser housing, the temperature measured by the sensor may differ from the temperature of the laser heterojunction. This temperature difference can be caused both by the transient process of heating or cooling the laser structure when the temperature changes to adjust the wavelength and by the specifics of the thermal resistances of the structural elements of the Peltier element, the cooling radiator, and the laser, which retain some temperature difference in thermal equilibrium after the end of the transition process. If the calibration of the dependence of the laser wavelength on temperature was performed for a structure used for deformation measurements, then the presence of this temperature difference would not affect the methodology and accuracy of deformation measurement, since the calculated wavelengths according to the calibration dependence would correspond to the true value of the laser radiation wavelength. To eliminate the influence of the transient thermal process on the measurement accuracy, it is sufficient to start recording the signal from the photodetector after establishing thermal equilibrium, which is easy to determine by stabilizing both the measured temperature and the average value of . The highest accuracy can be achieved by using a laser diode directly as a temperature sensor. However, the measuring device for this purpose is non-standard and requires calibration.
It is necessary to know the maximum value of
at
to determine the dependence of the strain value
on the dependencies
. In the above method, it was assumed that the spectral density of the radiation source was constant (i.e., either a broadband source or several lasers). In measurements with a sequential change in the wavelength of a semiconductor laser, it was also assumed that the laser radiation power was constant with a change in wavelength. However, when the temperature of a semiconductor laser changes, in addition to changing the wavelength, there may also be a change in the radiation power if the laser does not have thermal stabilization. If a semiconductor laser is equipped with a thermal stabilization system for the output radiation power, then power stabilization is performed by changing the laser current, which can also lead to a change in the laser radiation spectrum. Therefore, it is advisable to pre-measure the radiation spectrum of the selected semiconductor laser at different temperatures to obtain the calibration dependence
and the possibility of using it to determine the distribution of the strain
using a sequential change in the wavelength of the laser radiation. The semiconductor laser used in the experimental part of the work had a linear decrease in radiation power from temperature with the coefficient of 1.57% per degree Celsius. Therefore, when the histogram of the distribution of the magnitude of strain at the vibration (
Figure 13) was determined, the described influence was neglected.
The possible measurement range of strain (
) can be calculated using the formula:
where
is the number of wavelengths used. The
range is estimated at
for
= 10 and
nm, which corresponds to the parameters of the FBG used in the experimental part of the work. An increase in the
range can be achieved either by increasing the number of wavelengths used simultaneously, or by using fiber Bragg gratings with a wider spectral reflection band. Presumably, achieving a
measurement range of
or more is not a technical problem when using standard fiber-optic components.
The paper considered two types of dependence of the reflection spectrum of fiber Bragg gratings: trapezoidal and Gaussian. Such dependencies can be assumed to be a fairly accurate approximation of typical reflection spectra of FBG, which allowed us to obtain analytical expressions for calculating the strain of FBG (i.e., ). However, the algorithm discussed above can also be applied to other types of reflection spectra of FBG, if there is an unambiguous correspondence between the wavelength and the magnitude of the spectral density in a certain wavelength range. In this case, the dependence of can only be determined numerically.
8. Conclusions
The developed algorithm for determining changes in the strain of objects during vibration based on simultaneously measured power dependencies of the radiation reflected from the FBG can be implemented for various forms of the spectrum of the radiation reflected from the FBG without the need to sort through all the elements of the accumulated data arrays during their processing. In particular, the numerical simulation method demonstrated the possibility of modeling signals detected by photodetectors at various wavelengths, and the subsequent restoration of the dependence for the FBG and semiconductor lasers with typical parameters in the range up to .
The numerical simulation method showed and experimentally confirmed the occurrence of the second harmonic of the signal recorded by the photodetector and the disappearance of the first harmonic when the resonant wavelength of the FBG in the undeformed state coincided with the wavelength of the laser radiation at the sinusoidal linear vibration of the FBG.
It was also shown that it was possible to determine the probability density of the distribution for a stationary random process from the dependencies measured with successive changes in the wavelength of the radiation, which was confirmed by the results of the numerical simulation and experimental research.
The performed estimates showed that when using a semiconductor laser and a fiber Bragg grating with typical parameters, the accuracy of maintaining the laser temperature should be at least 0.1 °C for measurement at each wavelength.