Next Article in Journal
Wear Resistance and Biocompatibility of Co-Cr Dental Alloys Fabricated with CAST and SLM Techniques
Next Article in Special Issue
Fabrication of TiO2 ̶ KH550 ̶ PEG Super-Hydrophilic Coating on Glass Surface without UV/Plasma Treatment for Self-Cleaning and Anti-Fogging Applications
Previous Article in Journal
Research on Low-Frequency Noise Control of Automobiles Based on Acoustic Metamaterial
Previous Article in Special Issue
Measurement of Shear Strengths of Cu Films Using Precise Chip Forming
 
 
Article
Peer-Review Record

Friction and Wear Characteristics of Polydimethylsiloxane under Water-Based Lubrication Conditions

Materials 2022, 15(9), 3262; https://doi.org/10.3390/ma15093262
by Sung-Jun Lee 1,†, Yoon-Chul Sohn 2,† and Chang-Lae Kim 1,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Materials 2022, 15(9), 3262; https://doi.org/10.3390/ma15093262
Submission received: 26 March 2022 / Revised: 20 April 2022 / Accepted: 28 April 2022 / Published: 2 May 2022

Round 1

Reviewer 1 Report

comment on article :

Some sentences in the manuscript is too long and must be improved. Some sentences is not very comprehensible and must be improved. For exemple page 6 line 198-200, page 7 line 243-246.

improve quality of color bar of figures 4, 6 and 7. Could authors used the same level of color bar of this figure. This will improve the comprehension of the figures and make it possible to better see the extent of the wear. In fact, in FIG. 7 for example, the blue in the figure on the left corresponds to a depth of 1 μm, whereas in the figure on the right it corresponds to 80 μm. With the same scale, we will immediately see that the figure on the right shows greater wear.

 

In table 1. Max. load is 50 mN whereas on the text (line 115 page 3) maxiumu load is 500mN. Which value is good ?

Equation 1 to 4: could authors put reference of article in which this formula is derived.  

Figure 3: level of friction for 0.1 1, 10 and 100%wt is too low to be seen. Could authors put mean value of friction coefficient on the figure?

Explanation of wear mechanisms is not cleaur on page 7 line 254-257.

Authors say“When DI water is 261 used as a lubricant, relatively less wear of the PDMS occurs,” but on figure 4 it seems that wear is more importante in DI water lubricated conditions?

 

Major REvision

Author Response

Please check the attached file.

Author Response File: Author Response.pdf

Reviewer 2 Report

The appropriate file is attached.

Comments for author File: Comments.pdf

Author Response

Please check the attached file.

Author Response File: Author Response.pdf

Reviewer 3 Report

This paper aims to discuss the friction and wear of PDMS when using a lubricant compared with the dry condition.

The article is well organized and each section is well developed, showing the relevant results with an adequate discussion of them.

Although the paper is well written, some parts of the text must be revisited and rewritten to clarify the information to be passed for the reader. I suggest to review the entire paragraph that starts at line 49 to clarify the text.

In this way, I believe that the paper should be accepted for publishing with minor revisions in MDPI Materials.

Author Response

Please check the attached file.

Author Response File: Author Response.pdf

Back to TopTop