Next Article in Journal
Mechanical Properties of Cement Mortar Containing Ground Waste Newspaper as Cementitious Material
Next Article in Special Issue
Effect of Different Artificial Staining Procedures on the Color Stability and Translucency of a Nano-Hybrid Resin-Based Composite
Previous Article in Journal
Effects of Surface Treatment Conditions on the Bonding Strength and Electromagnetic Pulse Shielding of Concrete Using the 85Zn-15Al Arc Thermal Metal Spraying Method
Previous Article in Special Issue
Factory Crystallized Silicates for Monolithic Metal-Free Restorations: A Flexural Strength and Translucency Comparison Test
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Aesthetic Restorations: The Role of The Dental Hygienist in Professional Maintenance: In Vitro Microbiological Study

1
Center for Oral Hygiene and Prevention, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
2
Department of Dentistry, IRCCS San Raffaele Hospital, Dental School, Vita-Salute San Raffaele University, 20132 Milan, Italy
3
Dental School, Vita Salute University, 20132 Milan, Italy
4
Department of Dentistry, Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
*
Author to whom correspondence should be addressed.
Materials 2023, 16(4), 1373; https://doi.org/10.3390/ma16041373
Submission received: 9 December 2022 / Revised: 26 January 2023 / Accepted: 5 February 2023 / Published: 6 February 2023

Abstract

:
The aim of this in vitro study is to try to identify a treatment in the field of professional oral hygiene techniques that is ideal and less invasive with regard to prosthetic restorations, chosen in lithium disilicate and feldspar ceramics. Seventeen veneers were prepared (eight in lithium disilicate and nine in feldspar ceramic) and each of them was attached to an extracted tooth. The treatment groups were initially contaminated in the Microbiology Laboratory of Università Vita—Salute San Raffaele. After 24 h they were treated with four different methods of professional oral hygiene and were then sent to the Microscopy Laboratory, in which they were analysed by SEM, with 180X, 250X, and 500X magnification, to assess any damage caused to the treated surfaces. The SEM analysis produced 64 images that were evaluated by an experienced dentist, and the use of the prophetic cup seemed to be the most suitable among the evaluated treatments. However, from a microbiological point of view, this method was the least effective in terms of reducing bacterial growth. In this regard, the use of a prophylactic rubber cup combined with a 0.20% chlorhexidine gel is recommended during professional oral hygiene sessions for the maintenance of aesthetic prosthetic restorations.

1. Introduction

In the age of communication, smiles play a major role in interpersonal relationships.
Never like in this historical moment have aesthetics assumed such a fundamental importance. Indeed, a recent study points out that, due to the lockdown for the COVID-19 pandemic, cosmetic surgery operations have increased by 15%. The desire to restart after months spent at home has also increased the need for external renewal; moreover, communication through digital platforms has also led to a greater attention paid by the population to their external appearance [1,2].
Having a beautiful smile plays a key role in the perception that we have of ourselves; moreover, the pleasant appearance given by a beautiful smile facilitates and breaks down any barrier between us and others. In addition, a harmonious smile can help you feel more comfortable in everyday life because it increases self-esteem, both in the professional sphere and in any other relational activity [3,4,5,6,7,8,9,10].
The dental aesthetic takes care of the aesthetics of the smile, forming an integral and substantial part of the facial aesthetics. Indeed, it is a branch of dentistry that deals with modifying or removing the imperfections of the smile, which, as mentioned above, is considered a real business card of a person [11,12,13,14,15].
There are many techniques of intervention, from the most basic, such as the removal of extrinsic stains on dental surfaces, to the most complex and advanced dental whitening techniques. Some aesthetic techniques are implemented with adhesive modes and therefore there is no need to file the teeth; others, instead, are more invasive, such as the removal of old amalgam fillings and subsequent replacement with materials with excellent aesthetic performance, or the modification of the shape of the teeth with crowns or veneers made with different aesthetic materials [16,17,18].
The medium- and long-term success of aesthetic restorations is guaranteed by three main factors: patient compliance, personalised and specific follow-up, and the correct choice of oral hygiene techniques for professional maintenance.
Indeed, patients with aesthetic prosthetic rehabilitations is included in long-term follow-up programmes, whose protocol includes manoeuvres of quarterly and/or bi-annual professional oral hygiene, with precise instructions on the most suitable techniques and aids for domestic oral hygiene [19,20,21].
Therefore, the work of the dental team aims to acquire the necessary scientific knowledge about the properties and characteristics of the various devices to be used in a professional environment, so that they can choose the most suitable devices for each individual case.
The purpose of this work is to compare different methods of professional oral hygiene applied on prosthetic aesthetic elements: dental veneers.
After applying a known bacterial load, we evaluate which is the most effective professional therapy for oral hygiene in terms of removing bacterial biofilm and is the least invasive towards the surface of the prosthetic material.
After the experimental phase, in accordance with the scientific literature, precise and effective indications are provided regarding the most effective and least invasive professional oral hygiene treatment in the long-term maintenance of dental veneers.

2. Materials and Methods

2.1. Dental Veneers

Starting from the extracted dental elements, four hemi-arches were recreated. Subsequently, the elements on which to pack the aesthetic veneers in lithium disilicate and feldspar material were prosthetically prepared.
Each element was prosthetically prepared using a Chamfer procedure: n° 7 adjacent dental elements for model 0 and n° 8 adjacent dental elements for model X (model 0: 1.4,1.3,1.2,1.1,2.1,2.2,2.3 model X: 1.4,1.3,1.2,1.1,2.1,2.2,2.3,2.4) (Figure 1 and Figure 2).
A total of 15 aesthetic dental veneers were produced (Antonio Lazetera Dental Laboratory), 7 in lithium disilicate material and 8 in feldspathic material, each of which was fixed to the corresponding element extracted with Relix automix cement—Unicem 2, as per protocol. Clinical prosthesis shown in Figure 3.

2.2. Microbiology

A bacterial strain, ATCC 25922 Escherichia coli, was used for this study.
The organism was cultured on 5% Columbia blood agar plates (bd bbl stacker plates) and incubated at 35 °C overnight.
A 0.5 McFarland inoculum of ATCC 25922 was prepared in 3 mL of saline (Figure 4).

2.3. Consumables

Sterile cotton swabs, sterile tips (Costar), pipettes, 50 mL tubes (Falcon), and brain heart infusion (BHI) enrichment medium (Figure 5 and Figure 6) were used.

2.4. Instrumentation Products

  • White prophy cup
  • Cleanic® prophy paste based on perlite (Figure 7)
  • Air-Flow Master Piezon® EMS:
1–5 bar water supply, 5.5–7.5 bar compressed air supply, ultrasonic output max 12 Watts, frequency range 24–32 kHz.
  • EMS Air-Flow Plus® powder, based on erythritol, with Chlorhexidine (0.3%) average grain size 14 µm (Figure 8).
  • Clearfil Twist DIA polishers in two grain sizes, dark blue and light blue (Figure 9).

2.5. Types of Treatments

  • Treatment 1: prophy cup + Cleanic paste, 15′/surface at 1200 rpm.
  • Treatment 2: Air-Flow with Plus powder (erythritol with CHX) with tip angle of 30 °—60 °, 5 sec/surface at 5 mm distance from the surface.
  • Treatment 3: Clearfil Twist DIA rubber pads.
  • 1 pass DARK BLUE 15 sec/surface with 10,000 rpm speed.
  • 2 pass LIGHT BLUE 30 sec/surface with 10,000 rpm speed.
  • Treatment 4: Clearfil Twist DIA rubber pads + irrigation.
  • 1 pass DARK BLUE 15 sec/surface with 10,000 rpm speed.
  • 2 pass LIGHT BLUE 30 sec/surface with 10,000 rpm speed.

3. Methods

3.1. Preliminary Phase

A strain of Escherichia coli ATCC 25922 was inoculated on a blood agar plate at the Microbiology Laboratory of the Vita Salute San Raffaele University.
After 24 h, a single colony was taken and used to produce the mother culture: CM, pre-inoculated in 3 ml of physiological solution. The CM was prepared to obtain a known concentration of 0.5 McFarland.

3.2. Operational Phase

The dental veneers were contaminated by inserting them into a Falcon and adding the prepared inoculum to each surface (Figure 10).
Once the inoculation of all the samples was completed, they were placed in an incubator at 35 ± 2 °C for 24 h (Figure 11).
After 24 h from contamination, the samples were subjected to treatment with the various selected professional oral hygiene methods.

3.3. Working Groups

The 15 veneers cemented to the related dental elements through Relix—Unicem 2 automix cement were divided into 4 working groups composed of two veneers in lithium disilicate and two in feldspar. The control group consists of one lithium disilicate and two feldspar veneers.
  • GROUP A: Treatment 1—Cup with Cleanic prophy paste.
  • GROUP B Treatment 2—Air-Flow with Plus powder.
  • GROUP C: Treatment 3—Clearfil Twist DIA rubber pads.
  • GROUP D: Treatment 4—Clearfil Twist DIA rubber pads + irrigation.
  • GROUP E: Positive control.

3.4. Professional Instrumentation Techniques

All professional oral hygiene manoeuvres were performed according to the indications of the literature and the manufacturers of the products and tools used. They were performed by a single operator under standard conditions with a silicone base aid for the stability of the prosthetic elements.

3.5. Treatment 1

  • White prophy cup (WIEDER) with Cleanic® prophy paste based on perlite:
Used for 15′/surface at 1200 rpm with circular movements capable of wrapping the entire surface of the veneer (Figure 12).

3.6. Treatment 2

  • Air-Flow Master Piezon® EMS:
1–5 bar water supply, 5.5–7.5 bar compressed air supply, ultrasonic output max 12 Watt, frequency range 24–32 kHz. EMS Air-Flow Plus® powder based on erythritol with CHX (0.3%) grain size 14 μm. Used with the tip of the handpiece, with respect to the dental veneer, at an angle between 30° and 60°; the flow was directed for 5 sec/surface, maintaining a distance of 5 mm from the surface and making a circular movement (Figure 13).

3.7. Treatment 3

  • Clearfil Twist DIA—dark blue and light blue:
First pass: dark blue for 15 s on every surface with a speed of 10,000 rpm; second pass: light blue for 30 s on every surface with a speed of 10,000 rpm (Figure 14 and Figure 15).

3.8. Treatment 4

  • Clearfil Twist DIA—dark blue and light blue with irrigation:
First pass: dark blue for 15 s on each surface with a speed of 10,000 rpm; second pass: light blue for 30 s on each surface with a speed of 10,000 rpm (Figure 16 and Figure 17).

3.9. Microbiological Phase

At the end of the treatments, to carry out the evaluations, the veneers were inserted into a new 50 mL Falcon, cultured with the addition of a liquid enrichment medium BHI (brain heart infusion).
After vortexing, the T0 was collected with a duplicate volume of 50 μL and transferred to a blood agar plate and incubated at 35° ± 2 °C (Figure 18).
After 4 h, to evaluate T1, the operation of taking a sample in duplicate of 50 μL was repeated, and the sample was transferred to a blood agar plate and placed again in incubation at 35° ± 2 °C (Figure 19).

3.10. Microscopic Analysis with SEM (Scanning Electron Microscope)

The samples were inserted into the sample order, which was subsequently placed in the machine.
At this point, the sample image was loaded, an area of the sample was focused, and then the entire image was mapped.
Each sample was given a nomenclature called Label.
The analysis was carried out at 5 kV image quality, as the surface was the part being analysed.
On each sample insertion, the correct parameters such as contrast and zoom were manually set.
The lighter points correspond to the heavier elements; vice versa, the darker points represent lighter elements.
Images were taken for each sample at 180×, 250×, and 500×.
A total of 64 images were shot (Figure 20).

4. Results

4.1. Microbiological Results

Experiments conducted to assess residual bacterial load after professional oral hygiene treatments showed a lowering in bacterial count on all elements.
Further analysing the obtained data, we evaluated that in the first treatment (cup with prophetic paste), the bacterial load was similar in terms of quantity on cosmetic veneers in feldspar, compared to the same treatment on aesthetic veneers in disilicate at T1. An interesting fact was observed 4 h later at T2, because bacterial growth was greater on the feldspar surface. In addition, for the second treatment (Air-Flow with Plus powder), it can be noted that the results of the reduction in the bacterial load obtained a similar value for rehabilitation in feldspar and disilicate. As for the previous treatment, even in this case it was possible to evaluate a higher growth after 4 h at T2 on aesthetic dental veneers in feldspar.
With regard to the third treatment (Clearfil Twist rubber), a lower charge was obtained on the disilicate prostheses compared to feldspar, but at T2, it was possible to evaluate a different result where the feldspathic veneer showed less bacterial growth.
In the fourth treatment (Clearfil Twist + H2O rubber), an opposite effect was observed, as in the examination of the initial bacterial count, we saw a better result on the feldspar material than the disilicate. In this case, the effect was maintained even at 4 h at T2.
We can therefore evaluate how, in disilicate veneers, the treatment that obtained a better result at T1 was treatment 3 (Clearfil Twist DIA rubbers), while for feldspar, bacterial decontamination was the same in all treatments.
At T2, we can say that the treatment of choice for disilicate is treatment 2 (Air-Flow with Plus powder), while for feldspar, treatment 2 (Air-Flow with Plus powder) and treatment 4 (Clearfil Twist DIA + grommets) have the same effect in maintaining the bacterial load (Table 1 to Table 2).

4.2. Micromorphostructural Results

SEM analysis produced 64 images that were evaluated by an experienced dentist.
Each individual element was analysed in its vestibular portion through the SEM microscope to highlight the structural damage resulting from the four professional oral hygiene treatments carried out.
From the images collected for the disilicate samples treated with treatment 1 (prophylaxis cup with Cleanic paste), it emerged that in the lower magnification (180×), the surface appeared smoother than the surface of the control element. A similar image could be seen at a magnification of 250×, while at 500×, the circular marks left by the passage of the prophetic cup were evident (Figure 21 and Figure 22).
In addition, darker thickening areas were visible, which correspond to micro-dust residues present in the Cleanic paste.
From the images collected for disilicate samples treated with treatment 2 (Air-Flow with Plus powder), it was already clear from the lower 180× magnification that the surface had been polished, while at higher magnifications (250× and 500×), the surface appeared more irregular (with surface roughness) due to the pressure exerted by the air jet.
From the images collected for disilicate samples treated with treatment 3 and 4 (Clearfil Twist DIA without water for treatment 3 and Clearfil Twist DIA with water for treatment 4), the surface looked very smooth, especially in treatment 4, due to the abrasion of the first layer of material. Therefore, these treatments are considered more aggressive than others.
From the images collected for feldspathic ceramic samples treated with treatment 1 (prophylaxis cup with Cleanic paste), it emerged from the lower magnification (180×) that the surface was smooth and completely polished. At maximum magnification (500×), surface irregularities due to micro-dust residues in the Cleanic paste were noted. In addition, it emerged that the texture of the ceramic veneer was completely preserved.
Images of feldspar samples treated with treatment 2 (Air-Flow with Plus powder) showed darker areas due to the approach of the Air-Flow jet and lighter areas due to dust residues on the surface.
Feldspar samples treated with treatment 3 and 4 (Clearfil Twist DIA without water for treatment 3 and Clearfil Twist DIA with water for treatment 4) were, from the images obtained by SEM, polished to a level that affected the consistency of the ceramic feldspar.
Therefore, the results obtained under the SEM microscope show that the treatment with prophylaxis cup and Cleanic paste was the least aggressive in both materials of dental veneers, while the treatment with Air-Flow and Plus powder appears more invasive because it creates a less homogeneous surface in both materials used.
Finally, treatments with Clearfil Twist DIA, both with and without water, are the most aggressive of both the examined materials, to a greater extent in the feldspar ceramic veneers.

5. Discussion

Today, having a pleasant and healthy appearance is essential for the growth of interpersonal relationships, which are essential in both social and professional life.
The literature mainly describes protocols for proper professional oral hygiene in patients with fixed prosthetic products, but there is little evidence regarding cosmetic restorations [22].
An optimal adhesive restoration has been achieved in particular if the preparation has been fully inserted into the enamel, proper adhesive treatment procedures have been carried out, and a suitable fixing composite has been selected [23].
Professional oral hygiene techniques included in a personalised follow-up and recall program with proper plaque control at home become a guarantee of medium- and long-term success [24,25,26,27].
Tools used in professional oral hygiene, especially when used by inexperienced operators, can cause iatrogenic damage to prosthetic structures [28,29,30,31].
The literature describes another method to reduce gum inflammation and to comply with prosthetic manufacturers, as a laser, and Angiero et al. reported in 2019 you can use a low-level laser therapy neck with a 645 nm diode laser to reduce tissue inflammation and improve the healing phase of tissues.
To ensure the long-term permanence of prosthetic restorations, the dental hygienist must propose the most suitable and least invasive maintenance protocol for the patient.
Our goal, in fact, given the limited scientific evidence, was to verify the least harmful methods for the prosthetic ceramic surfaces with lithium disilicate and feldspar. Comparing them with the microbiological results, we had to verify the method which was the most effective in removing the bacterial biofilm and the least invasive towards the material used.
All the treatments used in the study have led to a reduction in bacterial load, a figure known in the literature with the exception of Clear Fil Twist DIA which, being a new product, has no scientific evidence to certify its effectiveness. The microbiological results showed that the treatment T1 3 (Clear Fil Twist DIA) in lithium disilicate products results in better results in terms of reduction in bacterial load. Since there are no references in the literature, this is not a confirmed result, but it can be an important basis for future research.
While at T1 in feldspar artifacts, treatments were equivalent, it is interesting to note that at T2 after 4 h, there was a reduction in bacterial growth in both feldspar products and lithium disilicate products.
These results clash with the microscopic SEM, but that have logic in the fact that a very invasive tool for the prosthetic surface is also able to efficiently remove bacterial biofilm.
Our results show that lithium disilicate veneers, due to their reduced thickness for aesthetic reasons, are more fragile than feldspar veneers [32].
As stated in the literature, ceramic veneers performed significantly better than indirect laminated composite veneers after a decade, both in terms of survival rate and quality of surviving restorations [33].
From the collected images, in fact, the surface irregularities were more visible in the disilicated samples, especially in the treatments that involved the use of Air-Flow and mechanical instruments with Clearfil Twist water grommets. The literature on the subject agrees in that Air-Flo is mainly used as the gold standard for the decontamination of more resistant surfaces, such as titanium implant surfaces or metal prostheses [34].
On the other hand, the prophylactic cup is the least aggressive towards both materials with which aesthetic prosthetic products have been made; in fact, various traditional polishing systems on materials such as zirconia and feldspar yield excellent results with low risk of wear or surface roughness [35].
Despite the limitations of this study, hoping for an enlargement of the examined sample, one might think that an elective treatment should be less aggressive and at the same time effective in terms of bacterial biofilm removal.
The use of the prophylactic cup, among the treatments evaluated, seems to be the most suitable method. However, as can be seen from microbiological analysis, it does not achieve statistically significant results in all samples in terms of reduced bacterial growth, especially at T2.
In this regard, it is recommended, in professional oral hygiene sessions for the maintenance of aesthetic prosthetic restorations, that hygienists use a rubber cup combined with a 0.20% chlorhexidine gel for prophylaxis.

6. Conclusions

Further in vivo and in vitro studies are necessary to verify the effectiveness of the treatment. However, the importance of our study lies precisely in the fact that there is very little evidence in the literature on the maintenance of aesthetic dental veneers and it was very rare to find references that used in vitro study, so this work can provide a basis to support practitioners in their clinical practice and, of course, to expand their knowledge on the subject.

Author Contributions

Conceptualization, E.P.; methodology, L.F.D.P. and M.H.; validation, E.P.; supervision, E.P.; resources, L.F.D.P.; data curation, L.F.D.P.; writing—editing, L.F.D.P. and G.T.; review and editing, E.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Ethics Committee of Vita-Salute San Raffaele University, Dental School Department of Dentistry IRCCS San Raffaele Hospital, Milan, 20132, Italy.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Data sharing not applicable. No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Capparè, P.; D’ambrosio, R.; De Cunto, R.; Darvizeh, A.; Nagni, M.; Gherlone, E. The usage of an air purifier device with HEPA 14 filter during dental procedures in COVID-19 pandemic: A randomized clinical trial. Int. J. Environ. Res. Public Health 2022, 19, 5139. [Google Scholar] [CrossRef]
  2. Polizzi, E.; Tetè, G. Manual vs Mechanical Oral Hygiene Procedures: Has the Role of the Dental Hygienist in Phase 2 Post-lockdown Really Changed? Oral Health Prev Dent. 2020, 18, 1031–1037. [Google Scholar] [CrossRef]
  3. Cattoni, F.; Teté, G.; Calloni, A.M.; Manazza, F.; Gastaldi, G.; Capparè, P. Milled versus moulded mock-ups based on the superimposition of 3D meshes from digital oral impressions: A comparative in vitro study in the aesthetic area. BMC Oral Health. 2019, 19, 230. [Google Scholar] [CrossRef]
  4. Tetè, G.; Polizzi, E.; D’orto, B.; Carinci, G.; Capparè, P. How to consider implant-prosthetic rehabilitation in elderly patients: A narrative review. J. Biol. Regul. Homeost. Agents 2021, 35, 119–126. [Google Scholar] [CrossRef]
  5. Cattoni, F.; Mastrangelo, F.; Gherlone, E.F.; Gastaldi, G. A New Total Digital Smile Planning Technique (3D-DSP) to Fabricate CAD-CAM Mockups for Esthetic Crowns and Veneers. Int. J. Dent. 2016, 2016, 6282587. [Google Scholar] [CrossRef]
  6. Ferrari Cagidiaco, E.; Carboncini, F.; Parrini, S.; Doldo, T.; Nagni, M.; Nuti, N.; Ferrari, M. Functional implant prosthodontic score of a one-year prospective study on three different connections for single-implant restorations. J. Osseointegration 2018, 10, 130–135. [Google Scholar] [CrossRef]
  7. Tecco, S.; Cattoni, F.; Darvizeh, A.; Bosco, F.; Sanci, V.; Nota, A.; Gastaldi, G.; Gherlone, E.F. Evaluation of Masticatory Muscle Function Using Digital versus Traditional Techniques for Mockup Fabrication: A Controlled Prospective Study. Appl. Sci. 2020, 10, 6013. [Google Scholar] [CrossRef]
  8. Cattoni, F.; Tetè, G.; Uccioli, R.; Manazza, F.; Gastaldi, G.; Perani, D. An fMRI Study on Self-Perception of Patients after Aesthetic Implant-Prosthetic Rehabilitation. Int. J. Environ. Res. Public Health 2020, 17, 588. [Google Scholar] [CrossRef]
  9. Crespi, R.; Capparè, P.; Polizzi, E.; Gherlone, E. Fresh-Socket Implants of Different Collar Length: Clinical Evaluation in the Aesthetic Zone. Clin. Implant. Dent. Relat. Res. 2015, 17, 871–878. [Google Scholar] [CrossRef]
  10. Crespi, R.; Capparè, P.; Polizzi, E.M.; Gherlone, E.F. Tissue remodeling after bone expansion in grafted and ungrafted sockets. Int. J. Oral Maxillofac. Implant. 2014, 29, 699–704. [Google Scholar] [CrossRef]
  11. Gastaldi, G.; Gherlone, E.; Manacorda, M.; Ferrini, F.; Bova, F.; Vinci, R.; Cattoni, F. A 3-D CAD/CAM technique in full-arch implant supported rehabilitations: The Virtual Implant-Prosthetic Procedure (VIPP Technique). A prospective longitudinal study. J. Osseointegration 2018, 10, 2–10. [Google Scholar]
  12. Manacorda, M.; Poletti de Chaurand, B.; Merlone, A.; Tetè, G.; Mottola, F.; Vinci, R. Virtual Implant Rehabilitation of the Severely Atrophic Maxilla: A Radiographic Study. Dent. J. 2020, 8, 14. [Google Scholar] [CrossRef]
  13. Cattoni, F.; Chirico, L.; Merlone, A.; Manacorda, M.; Vinci, R.; Gherlone, E.F. Digital Smile Designed Computer-Aided Surgery versus Traditional Workflow in “All on Four” Rehabilitations: A Randomized Clinical Trial with 4-Years Follow-Up. Int. J. Environ. Res. Public Health 2021, 18, 3449. [Google Scholar] [CrossRef]
  14. Manazza, F.; La Rocca, S.; Nagni, M.; Chirico, L.; Cattoni, F. A simplified digital workflow for the prosthetic finishing of implant rehabilitations: A case report. J. Biol. Regul. Homeost. Agents 2021, 35, 87–97. [Google Scholar] [CrossRef]
  15. Rebba, B.; Merlone, A.; Cantile, N.; Manazza, F.; Cattoni, F. Digital smile planning technique applied to prosthetic rehabilitation of dental esthetic area: A case report. J. Biol. Regul. Homeost. Agents 2021, 35, 1–9. [Google Scholar] [CrossRef]
  16. Lazetera, A.; Cattoni, F. Manual manufacturing of zirconia. Dent. Cadmos 2010, 78, 51–56. [Google Scholar]
  17. Gherlone, E.; Bollero, R.; Dolci, A.; Cattoni, F. The preparation of abutment-teeth with subgingival crown technique|La tecnica dei solchi guida nella preparazione dei denti pilastro. PROtech 2008, 9, 7–16. [Google Scholar]
  18. Cattoni, F.; Tetè, G.; D’orto, B.; Bergamaschi, A.; Polizzi, E.; Gastaldi, G. Comparison of hygiene levels in metal-ceramic and stratified zirconia in prosthetic rehabilitation on teeth and implants: A retrospective clinical study of a three-year follow-up. J. Biol. Regul. Homeost. Agents 2021, 35, 41–49. [Google Scholar] [CrossRef]
  19. Cappare, P.; Ferrini, F.; Mariani, G.; Nagni, M.; Cattoni, F. Implant rehabilitation of edentulous jaws with predominantly monolithic zirconia compared to metal-acrylic prostheses: A 2-year retrospective clinical study. J. Biol. Regul. Homeost. Agents 2021, 35, 99–112. [Google Scholar] [CrossRef]
  20. Cattoni, F.; Merlone, A.; Broggi, R.; Manacorda, M.; Vinci, R. Computer-assisted prosthetic planning and implant design with integrated digital bite registration: A treatment protocol. J. Biol. Regul. Homeost. Agents 2021, 35, 11–29. [Google Scholar] [CrossRef]
  21. Cattoni, F.; Chirico, L.; Cantile, N.; Merlone, A. Traditional prosthetic workflow for implant rehabilitations with a reduced number of fixtures: Proposal of a protocol. J. Biol. Regul. Homeost. Agents 2021, 35, 31–40. [Google Scholar] [CrossRef]
  22. Siadat, H.; Alikhasi, M.; Beyabanaki, E. Interim Prosthesis Options for Dental Implants. J Prosthodont. 2017, 26, 331–338. [Google Scholar] [CrossRef]
  23. Peumans, M.; Van Meerbeek, B.; Lambrechts, P.; Vanherle, G. Porcelain veneers: A review of the literature. J. Dent. 2000, 28, 163–177. [Google Scholar] [CrossRef]
  24. Tetè, G.; D’orto, B.; Ferrante, L.; Polizzi, E.; Cattoni, F. Role of mast cells in oral inflammation. J. Biol. Regul. Homeost. Agents 2021, 35, 65–70. [Google Scholar] [CrossRef]
  25. Merlone, A.; Tetè, G.; Cantile, N.; Manacorda, M.; Cattoni, F. Minimally invasive digital implant-prosthetic procedure in “all on 4” rehabilitation in patients with special needs: A three-year follow-up. J. Biol. Regul. Homeost. Agents 2021, 35, 71–85. [Google Scholar] [CrossRef]
  26. Tetè, G.; Cattoni, F.; Polizzi, E. Anti-discoloration system: A new chlorhexidine mouthwash. J. Biol. Regul. Homeost. Agents 2021, 35, 113–118. [Google Scholar] [CrossRef]
  27. Polizzi, E.; D’orto, B.; Tomasi, S.; Tetè, G. A micromorphological/microbiological pilot study assessing three methods for the maintenance of the implant patient. Clin. Exp. Dent. Res. 2021, 7, 156–162. [Google Scholar] [CrossRef]
  28. Angiero, F.; Ugolini, A.; Cattoni, F.; Bova, F.; Blasi, S.; Gallo, F.; Cossellu, G.; Gherlone, E. Evaluation of bradykinin, VEGF, and EGF biomarkers in gingival crevicular fluid and comparison of PhotoBioModulation with conventional techniques in periodontitis: A split-mouth randomized clinical trial. Lasers Med. Sci. 2020, 35, 965–970. [Google Scholar] [CrossRef]
  29. Mastrangelo, F.; Dedola, A.; Cattoni, F.; Ferrini, F.; Bova, F.; Tatullo, M.; Gherlone, E.; Lo Muzio, L. Etiological periodontal treatment with and without low-level laser therapy on IL-1β level in gingival crevicular fluid: An in vivo multicentric pilot study. J. Biol. Regul. Homeost. Agents 2018, 32, 425–431. [Google Scholar]
  30. Cattoni, F.; Pappalardo, S.; Vettese, P.; Santoro, G.; Gherlone, E. The laser technology in impression-taking technique and soft tissues management La tecnologia laser nel rilievo delle impronte in protesi fissa e nella gestione dei tessuti molli. PROtech 2007, 8, 17–27. [Google Scholar]
  31. Polizzi, E.; Tetè, G.; Targa, C.; Salviato, B.; Ferrini, F.; Gastaldi, G. Evaluation of the Effectiveness of the Use of the Diode Laser in the Reduction of the Volume of the Edematous Gingival Tissue after Causal Therapy. Int. J. Environ. Res. Public Health 2020, 17, 6192. [Google Scholar] [CrossRef]
  32. Tetè, G.; Sacchi, L.; Camerano, C.; Nagni, M.; Capelli, O.; Giuntoli Vercellin, S.; La Rocca, G.; Polizzi, E. Management of the delicate phase of the temporary crown: An in vitro study. J. Biol. Regul. Homeost. Agents 2020, 34, 69–80. [Google Scholar]
  33. Gresnigt, M.M.M.; Cune, M.S.; Jansen, K.; van der Made, S.A.M.; Özcan, M. Randomized clinical trial on indirect resin composite and ceramic laminate veneers: Up to 10-year findings. J. Dent. 2019, 86, 102–109. [Google Scholar] [CrossRef] [PubMed]
  34. Menini, M.; Delucchi, F.; Bagnasco, F.; Pera, F.; Di Tullio, N.; Pesce, P. Efficacy of air-polishing devices without removal of implant-supported full-arch prostheses. Int. J. Oral Implantol. 2021, 14, 401–416. [Google Scholar]
  35. Park, C.; Vang, M.S.; Park, S.W.; Lim, H.P. Effect of various polishing systems on the surface roughness and phase transformation of zirconia and the durability of the polishing systems. J. Prosthet. Dent. 2017, 117, 430–437. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Model 0.
Figure 1. Model 0.
Materials 16 01373 g001
Figure 2. Model X.
Figure 2. Model X.
Materials 16 01373 g002
Figure 3. Application of the adhesive.
Figure 3. Application of the adhesive.
Materials 16 01373 g003
Figure 4. Inoculum vials.
Figure 4. Inoculum vials.
Materials 16 01373 g004
Figure 5. Culture medium.
Figure 5. Culture medium.
Materials 16 01373 g005
Figure 6. Falcon 50mL.
Figure 6. Falcon 50mL.
Materials 16 01373 g006
Figure 7. Cup with Cleanic® prophy paste.
Figure 7. Cup with Cleanic® prophy paste.
Materials 16 01373 g007
Figure 8. Air-Flow Master Piezon® EMS with Air-Flow Plus® EMS powder.
Figure 8. Air-Flow Master Piezon® EMS with Air-Flow Plus® EMS powder.
Materials 16 01373 g008
Figure 9. Clearfil Twist DIA rubber pads.
Figure 9. Clearfil Twist DIA rubber pads.
Materials 16 01373 g009
Figure 10. Inoculation of the stock culture.
Figure 10. Inoculation of the stock culture.
Materials 16 01373 g010
Figure 11. Falcon samples in incubator.
Figure 11. Falcon samples in incubator.
Materials 16 01373 g011
Figure 12. Passing the cup with Cleanic® polishing paste.
Figure 12. Passing the cup with Cleanic® polishing paste.
Materials 16 01373 g012
Figure 13. Passage of Air-Flow Master Piezon® EMS using Plus powder.
Figure 13. Passage of Air-Flow Master Piezon® EMS using Plus powder.
Materials 16 01373 g013
Figure 14. Passage of the dark rubber.
Figure 14. Passage of the dark rubber.
Materials 16 01373 g014
Figure 15. Passage of the light rubber.
Figure 15. Passage of the light rubber.
Materials 16 01373 g015
Figure 16. Passage of the dark rubber.
Figure 16. Passage of the dark rubber.
Materials 16 01373 g016
Figure 17. Passage of the light rubber.
Figure 17. Passage of the light rubber.
Materials 16 01373 g017
Figure 18. Taking and placing sample on blood agar medium.
Figure 18. Taking and placing sample on blood agar medium.
Materials 16 01373 g018
Figure 19. Blood agar plates after incubation; elements of model X at the top, elements of model 0 at the bottom.
Figure 19. Blood agar plates after incubation; elements of model X at the top, elements of model 0 at the bottom.
Materials 16 01373 g019
Figure 20. SEM microscope: Phenom Pro G6.
Figure 20. SEM microscope: Phenom Pro G6.
Materials 16 01373 g020
Figure 21. Element 13 of model 0 in disilicate analysed under an SEM microscope at 180×, 250×, and 500× magnifications.
Figure 21. Element 13 of model 0 in disilicate analysed under an SEM microscope at 180×, 250×, and 500× magnifications.
Materials 16 01373 g021
Figure 22. Element 11 of model X in disilicate analysed under an SEM microscope at 180×, 250×, and 500× magnifications.
Figure 22. Element 11 of model X in disilicate analysed under an SEM microscope at 180×, 250×, and 500× magnifications.
Materials 16 01373 g022
Table 1. Table of disilicate veneers results indicated in cfu/mL.
Table 1. Table of disilicate veneers results indicated in cfu/mL.
Tooth ElementT0T1T2
X 11 disilicate- PROC.1CUP1.5 × 1084 × 1058 × 105
X 12 disilicate- PROC.1CUP1.5 × 1081.6 × 1053.2 × 105
X13 disilicate- PROC. 2 AIR FLOW1.5 × 1082.4 × 1057.2 × 105
X14 disilicate- PROC. 2 AIR FLOW1.5 × 1089 × 1042.7 × 105
021 disilicate- PROC.3 gum1.5 × 1081.54 × 1056.16 × 105
022 disilicate- PROC.3 gum + H2o1.5 × 1082.1 × 1058.4 × 105
023 disilicate- ctr. 1.5 × 1083.5 × 1051.4 × 104
Table 2. Table of disilicate veneers results indicated in cfu/mL.
Table 2. Table of disilicate veneers results indicated in cfu/mL.
Tooth ElementT0T1T2
O 11 feldspathic- PROC.1CUP1.5 × 1081.8 × 1055.2 × 105
O 12 feldspathic- PROC.1CUP1.5 × 1081.5 × 1056 × 105
0 13 feldspathic- PROC. 2 AIR FLOW1.5 × 1081.5 × 1056 × 105
0 14 feldspathic- PROC. 2 AIR FLOW1.5 × 1081.5 × 1044.5 × 105
X 22 feldspathic- PROC.3 gum1.5 × 1081.8 × 1055.4 × 105
X 21 feldspathic- PROC.3 gum + H2o1.5 × 1081.5 × 1054.5 × 105
X 23 feldspathic- ctr. 1.5 × 1085 × 1051.5 × 106
X 24 feldspathic- ctr.1.5 × 1086 × 1051.8 × 106
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Di Petto, L.F.; Tetè, G.; Hera, M.; Polizzi, E. Aesthetic Restorations: The Role of The Dental Hygienist in Professional Maintenance: In Vitro Microbiological Study. Materials 2023, 16, 1373. https://doi.org/10.3390/ma16041373

AMA Style

Di Petto LF, Tetè G, Hera M, Polizzi E. Aesthetic Restorations: The Role of The Dental Hygienist in Professional Maintenance: In Vitro Microbiological Study. Materials. 2023; 16(4):1373. https://doi.org/10.3390/ma16041373

Chicago/Turabian Style

Di Petto, Lorenza Francesca, Giulia Tetè, Mara Hera, and Elisabetta Polizzi. 2023. "Aesthetic Restorations: The Role of The Dental Hygienist in Professional Maintenance: In Vitro Microbiological Study" Materials 16, no. 4: 1373. https://doi.org/10.3390/ma16041373

APA Style

Di Petto, L. F., Tetè, G., Hera, M., & Polizzi, E. (2023). Aesthetic Restorations: The Role of The Dental Hygienist in Professional Maintenance: In Vitro Microbiological Study. Materials, 16(4), 1373. https://doi.org/10.3390/ma16041373

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop