Out-of-Plane Flexure of Masonry Panels with External Thermal Insulation
Abstract
:1. Introduction
2. Employed Loading Set-Up and Instrumentation
2.1. Test Set-Up and Instrumentation
2.2. Contents of the Present Study
3. Specimen Construction and Mechanical Properties of the Used Materials
3.1. Construction of the Tested Materials
3.2. Characterization of the Materials Used in Building the Masonry and the Thermo-Insulating Facades
4. Out-of-Plane Tests of the Masonry Wallets—Measurements
4.1. Out-of-Plane Load-Displacement Response of Masonry Wallet without or with Thermo-Insulating Attachment
- -
- Initially, the first cycles of small load-displacement amplitudes are demonstrating an almost linear response with an initial stiffness K0 = 20–24 kN/mm.
- -
- The gradual increase in the applied load-displacement amplitude is accompanied by a decrease in the obtained stiffness. For the masonry wallet without thermo-insuation the peak load, as expected, is reached within four loading cycles with a relatively small increase in the displacement amplitude and is accompanied with a sudden decrease of the bearing capacity and a large deformability (brittle behavior).
- -
- In contrast, all three specimens with thermo-insulation required a significant increase in the load and displacement amplitudes in order to reach the peak load beyond which a similar brittle behavior follows (4–8 loading cycles, Table 4). Until this peak “compressive” load is reached the subsequent loading cycles demonstrate a decreased stiffness (K1 = 15–5 kN/mm), compared to the K0 initial stiffness, together with load-displacement cycles with energy dissipation characteristics. The same can be observed but to a lesser degree when the load direction is reversed (“tensile” load). This must be attributed to the interaction of the thermo-insulation with the crack formation of the masonry substrate as well as the partial debonding. The ratio of the mid-height displacement for peak load over the corresponding “assumed yield” displacement increased from approximately 1.4 for the masonry wallet without thermo-insulation to approximately 2.0 for the wallets with XPS thermo-insulation and to approximately 3.0 for the wallets with either EPS or MW thermo-insulation (Table 4).
- -
- The peak load increase in absolute value terms is larger for the XPS and EPS thermo-insulation attachments than that observed for the mineral wool (MW) attachment. The opposite can be observed for the relative amplitude of plastic deformations before reaching the peak load; these are somewhat larger for the MW and EPS than for the XPS thermo-insulating attachments.
4.2. Masonry Wallet without Any Thermo-Insulating Attachment (Code Name WOP0A)
4.3. Masonry Wallet with a Mineral Wool (MW) Facade of 100 mm Thickness Subjected to Out-of-Plane Flexure (WOPM100A)
4.4. Masonry Wallet with an Expanded Polystyrene (EPS) Facade of 100 mm Thickness Subjected to Out-of-Plane Flexure (WOPE100A)
4.5. Masonry Wallet with an Extruded Polystyrene (XPS) Facade of 100 mm Thickness Subjected to Out-of-Plane Flexure (WOPX100B)
5. Observed Performance
5.1. Observed Out-of-Plane Performance of the Tested Wallets
5.2. Discussion of the Measured Behavior
- -
- The wallets having a thermo-insulating attachment showed an increase of the measured out-of-plane flexural capacity. When the thermo-insulating panels are subjected to tension form flexure and their thickness is 100 mm, this increase is 68%, 304%, 342% for the MW, the EPS and the XPS, respectively. A somewhat similar increase is also evident for the case with thermo-insulating panels having thickness equal to 50 mm.
- -
- A part of this increase is due to the adhesive mortar layer that is common to all the thermo-insulating attachments. Another part is due to the contribution of the various thermo-insulating materials. This contribution varies according to the corresponding variation of the tensile strength of the thermo-insulating materials in flexure.
- -
- A limiting factor in capitalizing on the flexural tensile strength of the insulating material is the relatively low bond strength between the adhesive mortar and these materials either in the tangential or in the normal direction of the bond surface (Table 3). This is evident from the fact that in almost all cases the limit state was that of debonding of the insulating panels either at the top or at the bottom of the masonry panel.
- -
- These thermo-insulating attachments, being under flexural tension, results in values of the out-of-plane displacements for peak compressive load significantly larger (XPS 3–6 mm, MW and EPS 5 mm) than those measured for the specimen without any thermo-insulating attachment (“bare”, 2 mm).
- -
- When the applied load was reversed, thus subjecting the thermo-insulating attachments in flexural compression, the increase of the out-of-plane flexural capacity was considerably smaller than the corresponding increase when the same insulating panels were under flexural tension. Contributing factors for this is the low compressive strength of these materials relatively to the corresponding tensile strength.
- -
- In all tested wallets, the presence of the thermo-insulating material did not alter the initial dominant flexural failure mode which, as expected, was the formation of horizontal cracks at the bed-joints near mid-height. This flexural response mechanism was accompanied in subsequent load cycles by the debonding of the insulating panels from the masonry substrate at the top and bottom horizontal boundaries of the tested specimens. In all cases, this debonding occurred for relatively large values (approximately more than 5 mm) for the out-of-plane displacements at mid-height of each wallet. For such large out-of-plane deformations the corresponding flexural capacity was significantly reduced.
- -
- Apart from the observed cracking and the subsequent debonding of the thermo-insulating attachments for such large out-of-plane displacements (in excess of 15 mm at mid-height of the wallet at the final loading stages) there was no incident of an insulating panel-unit detaching completely from the facade of the masonry wallet. This must be attributed to the protective action of the plastic anchors placed in key location for this purpose (Figure 13a-left).
- -
- The increase in the out-of-plane flexural capacity was larger for the EPS facades 100 mm thick than for those being 50 mm thick. However, for the XPS facades, the flexural capacity for a thermo-insulating facade 50 mm thick is larger than that for a facade 100 mm thick. This must be attributed to the fact that, due to a local weakness of the clay bricks in these XPS wallets, the local breaking of the masonry near the horizontal support developed apart from the cracking of the horizontal mortar joints and the debonding of the thermo-insulating facades from the masonry. As can be seen, the wallets with XPS facades resisted much higher out-of-plane loads than the corresponding EPS or MW wallets. This is partly due to the higher bond strength developed between the adhesive mortar the XPS panel combined with the higher flexural tensile strength of the XPS material itself than those for the EPS or MW (Table 3). The resulting higher value of the applied out-of-plane load resulted in certain cases to the breaking of the clay bricks, due to local weakness in the brick units.
- -
- Until this peak “compressive” load is reached the subsequent loading cycles demonstrate a decreased stiffness (K1 = 15–5 kN/mm), compared to the K0 initial stiffness (K0 = 24–20 kN/m), together with load-displacement cycles with energy dissipation characteristics. The same can be observed but to a lesser degree when the load direction is reversed (“tensile” load). This must be attributed to the interaction of the thermo-insulation with the crack formation of the masonry substrate as well as the partial debonding. The value of the ratio of the mid-height displacement for peak load over the corresponding “assumed yield” displacement increases from approximately 1.4 for the masonry wallet without thermo-insulation to approximately 2.0 for the wallets with XPS thermo-insulation and to approximately 3.0 for the wallets with either EPS or MW thermo-insulation.
6. Numerical Simulation of the Out-of-Plane Flexure for the Tested Wallets
6.1. Comparison between Numerical Predictions and Observed Behavior in the Current Study
6.1.1. Numerical Simulation of the Out-of-Plane Behavior of the Masonry Wallet without any Thermo-Insulating Attachment (“Bare”)
6.1.2. Numerical Simulation of the Out-of-Plane Behavior of the Masonry Wallet with Thermo-Insulating Attachment Made of Mineral Wool (“MW” with a Thickness of 100 mm)
6.1.3. Numerical Simulation of the Out-of-Plane Behavior of the Masonry Wallet with Thermo-Insulating Attachment Made of Expanded Polystyrene (“EPS” with a Thickness of 100 mm)
6.1.4. Numerical Simulation of the Out-of-Plane Behavior of the Masonry Wallet with Thermo-Insulating Attachment Made of Extruded Polystyrene (“XPS” with a Thickness of 100 mm)
- -
- The measured increase in the flexural capacity resulting from the addition of thermo-insulating facades is reasonably well predicted by the employed numerical simulation together with predicting the debonding mode of failure and the resulting decrease in the flexural bearing capacity as was measured during testing.
- -
- In all cases the measured out-of-plane flexibility of the tested wallets was larger than the one resulting from the numerical predictions. This is evident in all figures where the measured out-of-plane response is compared to the corresponding numerical predictions. This is also evident from the listed displacement values at peak load listed in Table 7 and must be partly attributed to the fact that the numerical analyses did not simulate the cyclic load reversals of the loading laboratory sequence and the corresponding gradual accumulation of micro-cracking and plastic deformations that occurred during the experiments. This issue is currently under study.
- -
- These observations are relevant only for the case that the direction of the out-of-plane loads result in a flexural behavior whereby the thermo-insulating attachments are under tension. As already discussed, based on the presented experimental evidence, when the direction of the out-of-plane loads subject the thermo-insulating attachments to compression the resulting flexural capacity increase is much smaller than when these thermo-insulation attachments are in tension. This experimental observation was also confirmed by the numerical predicted behavior.
- -
- Based on the above observations, it can be concluded that the employed numerical simulation, despite its limitations, yields reasonably realistic predictions of the bearing flexural capacity. It must be noted that this numerical simulation utilized all the necessary information relevant to the mechanical properties of all the employed materials as well as the necessary mechanical characteristics that govern the behavior at the contact surface between brick masonry, adhesive mortar and thermo-insulating panels.
- -
- Certain discrepancies between the peak measured flexural capacity and the one numerically predicted can be seen for the wallet having as thermo-insulating attachment the one constructed with extruded polystyrene (XPS 100 mm). This discrepancy was attributed to the local breaking of the clay cricks at the upper boundary of this wallet together with the initiation of the debonding, which resulted in a decrease of the bearing capacity. This underlines the importance of the boundary conditions and the performance of the masonry substrate at its peripheral supports. It also underlines the necessity in numerically simulating actual conditions. This very important issue is currently under study.
7. Discussion of the Outcome of the Current Study
- -
- The addition of thermo-insulating attachments resulted in an improved out-of-plane flexural behavior of the tested masonry wallets compared to the masonry wallet without any such attachment. This was demonstrated by the measured increase of the peak out-of-plane load bearing capacity and of the corresponding deformability of the tested specimens having such thermo-insulating attachments. This increase was quite substantial when the direction of the out-of-plane loads was subjecting these thermo-insulating facades to tension. When, for the reverse load direction, these facades were subjected to compression the observed performance improved to a much lesser degree.
- -
- For most cases, the prevailing mode of failure was the partial debonding of the thermo-insulating facades at their interface with the masonry substrate, being preceded by cracking of the horizontal mortar bed-joints at mid-height. Despite this partial debonding, the presence of the plastic anchors prohibited the total dislocation of these facades from the masonry substrate.
- -
- The observed improvement of the out-of-plane performance was more substantial for the XPS and EPS facades than for the MW facades. Moreover, an increase in the thickness of the thermo-insulating facade from 50 to 100 mm resulted in a noticeable improvement of the out-of-plane flexural performance. However, the increase in this way of the flexural capacity in terms of peak out-of-plane load resulted in the development of local breaking of the masonry at the supports, due to weakness of the used clay bricks. This type of damage limited any further improvement of the flexural capacity. This fact underlines the importance of investigating the capacity of the masonry substrate and the influence of its boundary conditions at the supports of such masonry facades prior to attaching the thermo-insulation attachments.
- -
- The employed numerical simulation proposes a multi-stage procedure employing basic information obtained from laboratory testing. Initially, a valid numerical simulation is formed for the “bare” masonry wallet. Next, this numerical simulation is extended to include the thermo-insulating attachment, utilizing in the subsequent non-linear analysis the obtained in the laboratory mechanical properties of the adhesive mortar and the thermo-insulating materials and their interaction. In this way, the non-linear analysis included realistic constitutive laws describing the interaction between the adhesive mortar interface with the masonry substrate and with the thermo-insulating panel-units. This procedure is of a general nature and can be employed for applications addressing different masonry or thermo-insulating materials.
- -
- From the comparison of the numerical predictions with the corresponding measurements, it can be concluded that a reasonable agreement can be reached for the flexural capacity, in terms of peak value for the applied out-of-plane load as well as for the observed debonding mode of failure. The better improvement of the flexural capacity of the XPS facade than that of the MW facade, which was observed during testing, was confirmed by the numerical predictions. These numerical simulations neither reproduced the observed out-of-plane flexural flexibility nor the local breaking of the masonry of the tested wallets. These issues should be addressed by future research.
8. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Modena, C.; Casarin, F.; da Porto, F.; Munari, M. L’Aquila 6th April 2009 Earthquake: Emergency and Post-emergency Activities on Cultural Heritage Buildings. Earthquake Engineering in Europe. In Geotechnical, Geological, and Earthquake Engineering; Springer Science + Business Media B.V.: Berlin, Germany, 2010; Volume 17, Chapter 20. [Google Scholar] [CrossRef]
- D’Ayala, D.; Dolce, M. Guest editorial: L’Aquila earthquake: Seismic sequence of 6th April 2009, Abruzzo, Italy. Bull. Earthq. Eng. 2011, 9, 1–10. [Google Scholar] [CrossRef]
- Manos, G. Consequences on the urban environment in Greece related to the recent intense earth-quake activity. Int. J. Civ. Eng. Archit. 2011, 5, 1065–1090. [Google Scholar]
- Papazachos, C.; Pavlides, S.; Chatzipetros, A.; Papathanassiou, G.; Valkaniotis, S.; Pitilakis, D.; Rouchotas, L. GEER/EERI/ATC Earthquake Reconnaissance, January 26th/February 2nd, 2014 Cephalonia, Greece Events. Version 1: June 6, 2014; GEER-EERI-ATC-Report; Edinburgh Napier University: Edinburgh, UK, 2014. [Google Scholar]
- Manos, G.C. The 30th of October Samos-Greece Earthquake. Issues relevant to the protection of structural damaged caused by strong earthquake ground motions. J. Archit. Eng. 2020, 5. [Google Scholar] [CrossRef]
- Holmes, M. Steel Frames with Brickwork and Concrete Infilling. Proc. Inst. Civ. Eng. 1961, 19, 473–478. [Google Scholar] [CrossRef]
- Holmes, M. Combined Loading on Infilled Frames. Proc. Inst. Civ. Eng. 1963, 25, 31–38. [Google Scholar] [CrossRef]
- Bryan, S.S. Behaviour of Square Infilled Frames. J. Struct. Div. ASCE 1966, 92, 381–404. [Google Scholar]
- Mallick, D.V.; Severn, R.T. The behaviour of infilled frames under static loading. Proc. Inst. Civ. Eng. 1967, 38 Pt 2, 639–656. [Google Scholar] [CrossRef]
- Stafford Smith, B.; Carter, C. A Method of Analysis for Infilled Frames. Inst. Civ. Eng. ICE 1969, 44, 31–48. [Google Scholar] [CrossRef]
- Mainstone, R.J. Supplementary Note on the Stiffnesses and Strengths of Infilled Frames; Current Paper CP 13/74; Building Research Station: Lahore, Pakistan, 1974. [Google Scholar]
- Klingner, R.E.; Bertero, V.V. Infilled Frames in Earthquake-Resistant Construction; EERC, Report No. 76-32; University of California: Berkeley, CA, USA, 1976. [Google Scholar]
- Dhanasekar, D.; Page, A.W. The influence of brick masonry infill properties on the behaviour of infilled frames. Proc. Inst. Civ. Eng. 1986, 81 Pt 2, 593–605. [Google Scholar]
- Zarnic, R.; Tomazevic, M. The Behaviour of Masonry Infilled Reinforced Concrete Frames Subjected to Cyclic Lateral Loading. In Proceedings of the Eighth World Conference on Earthquake Engineering, San Francisco, CA, USA, 21–28 July 1984. [Google Scholar]
- Styliniades, K. Experimental Investigation of the Behaviour of Single-Story Infilled R/C Frames under Cyclic Quasi-Static Horizontal Loading (Parametric Analysis). Ph.D. Thesis, Department of Civil Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece, 1985. [Google Scholar]
- Carydis, P.G.; Mouzakis, H.P.; Taflambas, J.M.; Vougioukas, E.A. Response of infilled frames with brickwalls to earthquake motions. In Proceedings of the 10th World Conference Earthquake Engineering, Madrid, Spain, 19–24 July 1992; pp. 2829–2834. [Google Scholar]
- Buonopane, S.G.; White, R.N. Pseudodynamic testing of masonry infilled reinforced concrete frame. J. Struct. Eng. 1999, 578–589. [Google Scholar] [CrossRef]
- Chiou, Y.C.; Tzeng, J.-C.; Liou, Y.W. Experimental and analytical study of Masonry Infilled Frames. J. Struct. Engrg. ASCE 1999, 125, 1109–1116. [Google Scholar] [CrossRef]
- Soulis, V. Investigation of the Numerical Simulation of Masonry Infilled R/C Frame Structures under Seismic Type Loading. Ph.D. Thesis, Department of Civil Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece, 2009. [Google Scholar]
- Thauampteh, J. Experimental Investigation of the Behaviour of Single-Story R/C Frames Infills, Virgin and Repaired, under Cyclic Horizontal Loading. Ph.D. Thesis, Department of Civil Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece, 2009. [Google Scholar]
- Da Porto, F.; Guidi, G.; Garbin, G.; Modena, C. In-plane behaviour of clay masonry walls: Experimental testing and finite element modelling. ASCE J. Struct. Eng. 2010, 136, 1379–1392. [Google Scholar] [CrossRef]
- Asteris, P.G. Special Issue on Infilled Framed Structures. Open Constr. Build. Technol. J. 2012, 6 (Suppl. 1), 32. [Google Scholar]
- Kadhim, J.A.; Dawood, A.O. Seismic Performance of Clay Bricks Construction. Civ. Eng. J. 2020, 6, 785–805. [Google Scholar] [CrossRef]
- Rastegarian, S.; Sharifi, A. An Investigation on the Correlation of Inter-story Drift and Performance Objectives in Conventional RC Frames. Emerg. Sci. J. 2018, 2, 140–147. [Google Scholar] [CrossRef]
- Umar, M.; Shah, S.A.A.; Shahzada, K.; Naqash, T.; Ali, W. Assessment of Seismic Capacity for Reinforced Concrete Frames with Perforated Unreinforced Brick Masonry Infill Wall. Civ. Eng. J. 2020, 6, 2397–2415. [Google Scholar] [CrossRef]
- Rahem, A.; Djarir, Y.; Noureddine, L.; Tayeb, B. Effect of Masonry Infill Walls with Openings on Nonlinear Response of Steel Frames. Civ. Eng. J. 2021, 7, 278–291. [Google Scholar] [CrossRef]
- Cavaleri, L.; Zizzo, M.; Asteris, P.G. Residual out-of-plane capacity of infills damaged by in-plane cyclic loads. Eng. Struct. 2020, 209, 109957. [Google Scholar] [CrossRef]
- Da Porto, F.; Grendene, M.; Mosele, F.; Modena, C. In-plane cyclic behaviour of load bearing masonry walls. In Proceedings of the 7th International Masonry Conference, London, UK, 30 October–1 November 2006. [Google Scholar]
- Ghosh, A.; Amde, A. Finite element analysis of infilled frames. J. Struct. Eng. 2002, 128, 881–889. [Google Scholar] [CrossRef]
- Manos, G.C.; Soulis, V.; Thauampteh, J. Nonlinear numerical model and its utilization in simulating the in-plane behaviour of multi-story R/C frames with masonry infills. Open Constr. Build. Technol. J. 2012, 6 (Suppl. 1-M16), 254–277. [Google Scholar] [CrossRef] [Green Version]
- Manos, G.C.; Soulis, V. Simulation of the in-plane seismic behaviour of masonry infills within Multistory Reinforced Concrete Framed Structures. In Proceedings of the 9th International Masonry Conference, Guimaraes, Portugal, 7–9 July 2014. [Google Scholar]
- Manos, G.C.; Soulis, V.J.; Thauampteh, J. The behaviour of masonry assemblages and masonry-infilled R/C frames subjected to combined vertical and cyclic horizontal seismic-type loading. Adv. Eng. Softw. 2012, 45, 213–231. [Google Scholar] [CrossRef]
- Focardi, F.; Manzini, E. Cyclic and Monotonic Diagonal Tension Tests on Various Shape Reinforced and Non-Reinforced Brick Panels. In Proceedings of the 8th European Conference on Earthquake Engineering, Lisbon, Portugal, 7–12 September 1986; Volume 4. [Google Scholar]
- Lourenco, P.B. Computational Strategies for Masonry Structures. Ph.D. Thesis, Delft University of Technology, Delft, The Netherlands, 1996. [Google Scholar]
- Lourenco, P.; Rots, J.G. On the Use of Micro-Models for the Analysis of Masonry Shear-Walls; Pande, G.N., Middleton, J., Eds.; Computer Methods in Structural Masonry-2: Swansea, UK, 1993; pp. 14–25. [Google Scholar]
- Mehrabi, A.B.; Shing, P. Finite element modelling of masonry-infilled RC frames. J. Struct. Eng. 1997, 123, 604–613. [Google Scholar] [CrossRef]
- Lavado, J.L.; Gallardo, C.H. Experimental and numerical analysis of behaviour of old brick masonries. In Proceedings of the 17th World Conference on Earthquake Engineering, Sendai, Japan, 14–18 September 2020. [Google Scholar] [CrossRef]
- Janaraj, T.; Dhanasekar, M. Effectiveness of Two Forms of Grouted Reinforced Confinement Methods to Hollow Concrete Masonry Panels. J. Mater. Civ. Eng. 2015, 27, 04015038. [Google Scholar] [CrossRef] [Green Version]
- De Carvalho Bello, C.B.; Cecchi, A.; Meroi, E.; Oliveira, D.V. Experimental and numerical investigations on the behaviour of masonry walls reinforced with an innovative sisal FRCM system. Key Eng. Mater. 2017, 747, 190–195. [Google Scholar] [CrossRef]
- Rousakis, T.; Ilki, A.; Kwiecien, A.; Viskovic, A.; Gams, M.; Triller, P.; Bogdanovic, A. Deformable polyurethane joints and fibre grids for resilient seismic performance of reinforced concrete frames with orthoblock brick infills. Polymers 2020, 12, 2869. [Google Scholar] [CrossRef] [PubMed]
- Bolhassani, M.; Hamid, A.A.; Lau, A.C.W.; Moon, F. Simplified micro modeling of partially grouted masonry assemblages. Constr. Build. Mater. 2015, 83, 159–173. [Google Scholar] [CrossRef]
- Arnau, O.; Sandoval, C.; Murià-Vila, D. Determination and validation of input parameters for detailed micro- modelling of partially grouted reinforced masonry walls. In Proceedings of the Tenth Pacific Conference on Earthquake Engineering, Sydney, Australia, 6–8 November 2015; Volume 110. [Google Scholar]
- Sandoval, C.; Arnau, O. Experimental characterization and detailed micro-modeling of multi-perforated clay brick masonry structural response. Mater. Struct. 2017, 50, 34. [Google Scholar] [CrossRef]
- Malomo, D.; DeJong, M.J.; Penna, A. A Homogenized Distinct Macro-Block (HDM) Model for Simulating the In-Plane Cyclic Response of URM Walls. In Proceedings of the 13th North American Masonry Conference, Salt Lake, UT, USA, 16–19 June 2019; Volume 1, pp. 1042–1054. [Google Scholar]
- Domede, N.; Sellier, A. Experimental and numerical analysis of behaviour of old brick masonries. Adv. Mater. Res. 2010, 133–134, 307–312. [Google Scholar] [CrossRef]
- EN 1998-1/2005-05-12. Eurocode 8: Design of Structures for Earthquake Resistance—Part1: General Rules, Seismic Actions and Rules for Buildings. Available online: https://www.saiglobal.com/PDFTemp/Previews/OSH/IS/EN/2005/I.S.EN1998-1-2005.pdf (accessed on 2 August 2021).
- La Greca, P.; Margani, G. Seismic and energy renovation measures for sustainable cities: A critical analysis of the Italian scenario. Sustainability 2018, 10, 254. [Google Scholar] [CrossRef] [Green Version]
- Leone, M.F.; Zuccaro, G. Seismic and Energy Retrofitting of Residential Buildings: A Simulation—Based Approach. UPLanD 2016, 1, 11–25. [Google Scholar]
- Manos, G.C.; Melidis, L.; Katakalos, K.; Kotoulas, L.; Anastasiadis, A.; Chatziastrou, C. Masonry panels with external thermal insulation subjected to in-plane diagonal compression. Case Stud. Constr. Mater. 2021, 14, e00538. [Google Scholar] [CrossRef]
- Antoniadou, P.; Symeonidou, M.; Kyriaki, E.; Giama, E.; Boemi, S.N.; Chadiarakou, S.; Papadopoulos, A.M. High performance building façades for Zero Energy Buildings in Greece: State of the art and perspectives. IOP Conf. Ser. Earth Environ. Sci. 2020, 410, 012036. [Google Scholar] [CrossRef]
- Papadopoulos, A.M. State of the art in thermal insulation materials and aims for future developments. Energy Build. 2005, 37, 77–86. [Google Scholar] [CrossRef]
- Touloupaki, E.; Theodosiou, T. Optimization of external envelope insulation thickness: A parametric study. Energies 2017, 10, 270. [Google Scholar] [CrossRef] [Green Version]
- Norvaišienė, R.; Buhagiar, V.; Burlingis, A.; Miškinis, K. Investigation of mechanical resistance of external thermal insulation composite systems (ETICS). J. Build. Eng. 2020, 32, 101682. [Google Scholar] [CrossRef]
- Uygunoğlu, T.; Özgüven, S.; Çalış, M. Effect of plaster thickness on performance of external thermal insulation cladding systems (ETICS) in buildings. Constr. Build. Mater. 2016, 122, 496–504. [Google Scholar] [CrossRef]
- Bournas, D.A. Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept. Compos. Part B Eng. 2018, 148, 166–179. [Google Scholar] [CrossRef]
- Triantafillou, T.C.; Karlos, K.; Kapsalis, P.; Georgiou, L. Innovative Structural and Energy Retrofitting System for Masonry Walls Using Textile Reinforced Mortars Combined with Thermal Insulation: In-Plane Mechanical Behaviour. J. Compos. Constr. 2018, 22, 04018029. [Google Scholar] [CrossRef]
- Gkournelos, P.D.; Triantafillou, T.C.; Bournas, D.A. Integrated Structural and Energy Retrofitting of Masonry Walls: Effect of In-Plane Damage on the Out-of-Plane Response. J. Compos. Constr. 2020, 24, 04020049. [Google Scholar] [CrossRef]
- Borri, A.; Corradi, M.; Sisti, R.; Buratti, C.; Belloni, E.; Moretti, E. Masonry wall panels retrofitted with thermal-insulating GFRP-reinforced jacketing. Mater. Struct. 2016, 49, 3957–3968. [Google Scholar] [CrossRef] [Green Version]
- Manos, G.; Katakalos, K.; Melidis, L.; Anastasiadis, A. The behaviour of masonry infills with thermal insulation facades under out of plane seismic type loads (In Greek). In Proceedings of the 4th Panhellenic Conference on Earthquake Engineering and Technical Seismology, Athens, Greece, 5–7 September 2019. [Google Scholar]
- Manos, G.; Melidis, L.; Katakalos, K.; Soulis, V.; Anastasiadis, A. Unreinforced masonry with thermal insulation facades in multi-story buildings subjected to seismic type loads. In Proceedings of the 17th World Conference on Earthquake Engineering, Sendai, Japan, 13–18 September 2020. [Google Scholar]
- Pohoryles, D.A.; Maduta, C.; Bournas, D.A.; Kouris, L.A. Energy performance of existing residential buildings in Europe: A novel approach combining energy with seismic retrofitting. Energy Build. 2020, 223, 110024. [Google Scholar] [CrossRef]
- Gattesco, N.; Boem, I. Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes. Constr. Build. Mater. 2015, 88, 94–104. [Google Scholar] [CrossRef]
- Gattesco, N.; Amadio, C.; Bedon, C. Experimental and numerical study on the shear behaviour of stone masonry walls strengthened with GFRP reinforced mortar coating and steel-cord reinforced repointing. Eng. Struct. 2015, 90, 143–157. [Google Scholar] [CrossRef] [Green Version]
- Thomoglou, A.K.; Rousakis, T.C.; Achillopoulou, D.V.; Karabinis, A.I. Ultimate Shear Strength Prediction Model for Unreinforced Masonry Retrofitted Externally with Textile Reinforced Mortar. Earthq. Struct. 2020, 19, 411–425. [Google Scholar] [CrossRef]
- Jafari, A.; Oskouei, A.V.; Bazli, M.; Ghahri, R. Effect of the FRP sheet’s arrays and NSM FRP bars on in-plane behaviour of URM walls. J. Build. Eng. 2018, 20, 679–695. [Google Scholar] [CrossRef]
- Thomoglou, A.; Rousakis, T.; Karabinis, A. Numerical Modeling of Shear Behavior of Urm Strengthened with Frcm or Frp Subjected to Seismic loading. In Proceedings of the 16th European Conference on Earthquake Engineering, Thessaloniki, Greece, 18–21 June 2018; pp. 1–10. [Google Scholar]
- Spyrakos, C.C.; Maniatakis, C.A.; Psycharis, I.N.; Smyarou, E.; Asteris, P.G. Validation of analytical models for the assessment of brick-infilled RC frames strengthened with FRPs. In Proceedings of the 4th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Kos Island, Greece, 12–14 June 2013; pp. 2978–2996. [Google Scholar] [CrossRef] [Green Version]
- Derakhshan, H.; Dizhur, D.; Griffith, M.C.; Ingham, J.M. In Situ Out-of-Plane Testing of As-Built and Retrofitted Unreinforced Masonry Walls. J. Struct. Eng. 2014, 140, 04014022. [Google Scholar] [CrossRef] [Green Version]
- Reboul, N.; Si Larbi, A.; Ferrier, E. Two-way bending behaviour of hollow concrete block masonry walls reinforced by composite materials. Compos. Part B Eng. 2018, 137, 163–177. [Google Scholar] [CrossRef]
- D’Ambrisi, A.; Mezzi, M.; Caporale, A. Experimental investigation on polymeric net-RCM reinforced masonry panels. Compos. Struct. 2013, 105, 207–215. [Google Scholar] [CrossRef]
- Sagar, S.L.; Singhal, V.; Rai, D.C.; Gudur, P. Diagonal shear and out-of-plane flexural strength of fabric-reinforced cementitious matrix-strengthened masonry walletes. J. Compos. Constr. 2017, 21, 04017016. [Google Scholar] [CrossRef]
- Babaeidarabad, S.; De Caso, F.; Nanni, A. Out-of-Plane Behavior of URM Walls Strengthened with Fabric-Reinforced Cementitious Matrix Composite. J. Compos. Constr. 2014, 18, 04013057. [Google Scholar] [CrossRef]
- Kariou, F.A.; Triantafyllou, S.P.; Bournas, D.A.; Koutas, L.N. Out-of-plane response of masonry walls strengthened using textile-mortar system. Constr. Build. Mater. 2018, 165, 769–781. [Google Scholar] [CrossRef] [Green Version]
- D’Ambra, C.; Lignola, G.P.; Prota, A.; Sacco, E.; Fabbrocino, F. Experimental performance of FRCM retrofit on out-of-plane behaviour of clay brick walls. Compos. Part B Eng. 2018, 148, 198–206. [Google Scholar] [CrossRef]
- Thermou, G.E.; Katakalos, K.; Manos, G. Influence of the loading rate on the axial compressive behavior of concrete specimens confined with SRG jackets. In Proceedings of the 4th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Kos Island, Greece, 12–14 June 2013; pp. 1107–1122. [Google Scholar] [CrossRef] [Green Version]
- Thermou, G.E.; Katakalos, K.; Manos, G. Concrete confinement with steel-reinforced grout jackets. Mater. Struct. 2015, 48, 1355–1376. [Google Scholar] [CrossRef]
- Banerjee, S.; Nayak, S.; Das, S. Shear and flexural behaviour of unreinforced masonry wallets with steel wire mesh. J. Build. Eng. 2020, 30, 101254. [Google Scholar] [CrossRef]
- Willis, C.R.; Seracino, R.; Griffith, M.C. Out-of-plane strength of brick masonry retrofitted with horizontal NSM CFRP strips. Eng. Struct. 2010, 32, 547–555. [Google Scholar] [CrossRef]
- Dizhur, D.; Griffith, M.; Ingham, J. Out-of-plane strengthening of unreinforced masonry walls using near surface mounted fibre reinforced polymer strips. Eng. Struct. 2014, 59, 330–343. [Google Scholar] [CrossRef]
- Türkmen, S.; Wijte, S.N.M.; De Vries, B.T.; Ingham, J.M. Out-of-plane behavior of clay brick masonry walls retrofitted with flexible deep mounted CFRP strips. Eng. Struct. 2021, 228, 111448. [Google Scholar] [CrossRef]
- Gattesco, N.; Boem, I. Out-of-plane behavior of reinforced masonry walls: Experimental and numerical study. Compos. Part B Eng. 2017, 128, 39–52. [Google Scholar] [CrossRef] [Green Version]
- Griffith, M.C.; Kashyap, J.; Mohamed Ali, M.S. Flexural displacement response of NSM FRP retrofitted masonry walls. Constr. Build. Mater. 2013, 49, 1032–1040. [Google Scholar] [CrossRef]
- Lin, Y.; Lawley, D.; Wotherspoon, L.; Ingham, J.M. Out-of-plane Testing of Unreinforced Masonry Walls Strengthened Using ECC Shotcrete. Structures 2016, 7, 33–42. [Google Scholar] [CrossRef]
- Ismail, N.; Ingham, J.M. Cyclic Out-of-Plane Behavior of Slender Clay Brick Masonry Walls Seismically Strengthened Using Posttensioning. J. Struct. Eng. 2012, 138, 1255–1266. [Google Scholar] [CrossRef]
- Ismail, N.; Ingham, J.M. In-situ and laboratory based out-of-plane testing of unreinforced clay brick masonry walls strengthened using near surface mounted twisted steel bars. Constr. Build. Mater. 2012, 36, 119–128. [Google Scholar] [CrossRef]
- Khan, H.A.; Nanda, R.P. Out-of-plane bending of masonry wallette strengthened with geosynthetic. Constr. Build. Mater. 2020, 231, 117198. [Google Scholar] [CrossRef]
- Mishra, C.; Yamaguchi, K.; Endο, Y.; Hanazato, T.; Shakya, M. Study on shear and flexural behavior of Νepalese masonry walls with and without reinforcement. In Proceedings of the 17th World Conference on Earthquake Engineering, Sendai, Japan, 13–18 September 2020. [Google Scholar]
- EN1996-1-1:1998 Eurocode 6—Design of Masonry Structures—Part 1-1: General Rules for Reinforced and Unreinforced Masonry Structures. Available online: https://www.phd.eng.br/wp-content/uploads/2015/02/en.1996.1.1.2005.pdf (accessed on 2 August 2021).
- EN 1015:1999 Methods of Test for Mortar for Masonry—Part 11: Determination of Flexural and Compressive Strength of Hardened Mortar. Available online: https://standards.iteh.ai/catalog/standards/cen/251c5fb4-ef60-4285-9039-be39d56242d3/en-1015-11-1999-a1-2006 (accessed on 2 August 2021).
- EN 772-1: 2011—Methods of Test for Masonry Units—Part 1: Determination of Compressive Strength. Available online: https://standards.iteh.ai/catalog/standards/cen/e16d7005-8730-4382-9a9d-4d351d00f981/en-772-1-2011 (accessed on 2 August 2021).
- EN 826:2013—Thermal Insulating Products for Building Applications. Determination of Compression Behaviour. Available online: https://standards.iteh.ai/catalog/standards/cen/f54055a6-cacc-4d69-b85a-b190aea8ed7f/en-826-2013 (accessed on 2 August 2021).
- EN 1607:2013—Thermal Insulating Products for Building Applications. Determination of Tensile Strength Perpendicular to Faces. Available online: https://shop.bsigroup.com/ProductDetail?pid=000000000030259091 (accessed on 2 August 2021).
- EN 12089:2013—Thermal Insulating Products for Building Applications—Determination of Bending Behaviour. Available online: https://shop.bsigroup.com/ProductDetail?pid=000000000030259152 (accessed on 2 August 2021).
- EN 12090:2013—Thermal Insulating Products for Building Applications. Determination of Shear Behaviour. Available online: https://shop.bsigroup.com/ProductDetail/?pid=000000000030259140 (accessed on 2 August 2021).
- EN 1542:1999—Products and Systems for the Protection of Concrete Structures- Test Methods—Measurements of Bond Strength by Pull-Off. Available online: https://shop.bsigroup.com/ProductDetail?pid=000000000019972442 (accessed on 2 August 2021).
- Asteris, P.G.; Antoniou, S.T.; Sophianopoulos, D.S.; Chrysostomou, C.Z. Mathematical Macromodeling of Infilled Frames: State of the Art. J. Struct. Eng. 2011, 137, 1508–1517. [Google Scholar] [CrossRef]
- Asteris, P.G.; Cotsovos, D.M.; Chrysostomou, C.Z.; Mohebkhah, A.; Al-Chaar, G.K. Mathematical micromodeling of infilled frames: State of the art. Eng. Struct. 2013, 56, 1905–1921. [Google Scholar] [CrossRef]
- Lourenço, P.B.; De Borst, R.; Rots, J.G. A plane stress softening plasticity model for orthotropic materials. Int. J. Numer. Methods Eng. 1997, 40, 4033–4057. [Google Scholar] [CrossRef]
- Noor-E-Khuda, S.; Dhanasekar, M.; Thambiratnam, D.P. Out-of-plane deformation and failure of masonry walls with various forms of reinforcement. Compos. Struct. 2016, 140, 262–277. [Google Scholar] [CrossRef] [Green Version]
- Galvez, F.; Segatta, S.; Giaretton, M.; Walsh, K.; Giongo, I.; Dizhur, D. FE and DE modelling of out-of-plane two way bending behaviour of unreinforced masonry walls. In Proceedings of the 16th European Conference on Earthquake Engineering—ECEE, Thessaloniki, Greece, 18–21 June 2018; pp. 1–11. [Google Scholar]
- Abaqus Unified FEA—SIMULIA™ by Dassault Systèmes. Available online: https://www.3ds.com/products-services/simulia/products/abaqus/ (accessed on 2 August 2021).
- Lubliner, J.; Oliver, J.; Oller, S.; Oñate, E. A plastic-damage model for concrete. Int. J. Solids Struct. 1989, 25, 299–326. [Google Scholar] [CrossRef]
- Lee, J.; Fenves, G.L. Plastic-Damage Model for Cyclic Loading of Concrete Structures. J. Eng. Mech. 1998, 124, 892–900. [Google Scholar] [CrossRef]
Measured Masonry Compressive Strength | Masonry Compressive Strength Euro-Code 6 [46] | Measured Masonry Flexural Strength Normal to Bed-Joint (fxk1) |
---|---|---|
(1) | (2) | (3) |
1.02 MPa | 0.94 MPa (for K = 0.35) | Average = 0.168 MPa (SDV = 0.035 MPa) |
Bond between the Adhesive Mortar and the Thermal Insulating Panel (Normal to the Facade) (MPa) | ||
---|---|---|
MW | EPS | XPS |
Mean = 0.068 SDV = 0.023 | Mean = 0.105 SDV = 0.012 | Mean = 0.178 SDV = 0.068 |
Code Name | WOP0A | WOPX50 A | WOPX100 B | WOPE50 A | WOPE50 B | WOPE100 A | WOPM100 A |
---|---|---|---|---|---|---|---|
Type of thermo-insulation * | No | XPS | XPS | EPS | EPS | EPS | MW |
Thickness (mm) | 0 | 50 | 100 | 50 | 50 | 100 | 100 |
(1) Code Name/insulation thickness (mm) | WOP0A/0 mm | WOPX50A/50 mm | WOPX100B/100 mm | WOPE50A/50 mm | WOPE50B/50 mm | WOPE100A/100 mm | WOPM100A/100 mm |
(2) Type of thermal Insulation * | “Bare” without | Extruded polystyrene (XPS) | Extruded polystyrene (XPS) | Expanded polystyrene (EPS) | Expanded polystyrene (EPS) | Expanded polystyrene (EPS) | Mineral wool (MW) |
(3) Minimum “compressive” load (kN)/mid-height displ. (mm) ** | −8.81 kN/2 mm | −44.48 kN/6 mm | −38.91 kN/3 mm | −25.23 kN/4 mm | −27.30 kN/5 mm | −35.62 kN/5 mm | −14.77 kN/5 mm |
(4) Maximum “tensile” load (KN)/mid-height displ. (mm) *** | 1.01 kN/1.5 mm | 5.02 kN/2 mm | 14.86 kN/1.5 mm | 10.21 kN/1.5 mm | Not tested | 2.45 kN/5 mm | 5.21 kN/5 mm |
(5) Increase (%) in the “compressive” load compared to the control masonry wallet without thermo-insulation *** | 0% | 405% | 342% | 186% | 210% | 304% | 68% |
(6) Increase in the “tensile” load (compared to “bare” %) **** | 0% | Damaged before by “compression” | 69% | 16% | Not tested | Damaged before by “compression” | Damaged before by “compression” |
(7) Number of cycles till peak load (“compressive”) is reached/after peak load | 4/1 | 4/1 | 7/1 | 8/2 | 7/1 | 6/2 | 7/3 |
(8) Initial stiffness (K0) and/stiffness before reaching peak load (K1) kN/mm | K0 = 20 | K0 = 20/K1 = 10 | K0 = 24/K1 = 15 | K0 =20/K1 = 6.7 | K0 = 24/K1 = 6 | K0 =20/K1 = 8 | K0 = 20/K1 = 4 |
(9) Ratio of mid-height displ. for the peak load by assumed yield displacement | 1.41 | 2.01 | 1.99 | 3.11 | 3.0 | 3.08 | 3.25 |
(10) Observed damage /corresponding out-of-plane displacement at mid-height (mm) | Horizontal crack at mid-height (3 mm) | Horizontal crack at mid-height/debonding at bottom (15 mm) | Horizontal crack at mid-height/debonding at top (15 mm | Horizontal crack at mid-height/debonding at top (15 mm) | Horizontal crack at mid-height/debonding at bottom (15 mm) | Horizontal crack at mid-height/debonding at top (15 mm) | Horizontal crack at mid-height/debonding at top (15 mm) |
Material Model Assigned to Masonry Panel | |||||
---|---|---|---|---|---|
General Properties | Compressive Behavior | Tensile Behavior | |||
Density | 1.00 tn/m3 | Yield stress | Inelastic strain | Yield stress | Inelastic strain |
Young’s modulus | 750 MPa | 13.50 MPa | 0.00 | 2.30 MPa | 0.00 |
Poisson’s ratio | 0.20 | 0.13 MPa | 0.02 | 0.05 | 0.02 |
CDP Constitutive Law for the Strong Adhesive Mortar | |||||
---|---|---|---|---|---|
General Properties | Compressive Behavior | Tensile Behavior | |||
Density | 1.00 tn/m3 | Yield stress | Inelastic strain | Yield stress | Inelastic strain |
Young’s modulus | 1000 MPa | 13.50 MPa | 0.00 | 2.30 MPa | 0.00 |
Poisson’s ratio | 0.20 | 0.13 MPa | 0.02 | 0.05 MPa | 0.02 |
Experimental Measurements for Compressive Force | Numerical Predictions for Compressive Force | |||
---|---|---|---|---|
Description | Absolute maximum load (kN)/Hor. displ. (mm) | Increase in the flexural bearing capacity * | Absolute maximum load (kN)/Hor. displ. (mm) | Increase in the flexural bearing capacity ** |
Bare masonry | 8.81 kN/1 mm | 0% | 8.88 kN/0.9 mm | 0% |
MW 100 mm | 14.77 kN/5 mm | 68% | 13.35 kN/1.5 mm | 50% |
EPS 100 mm | 35.62 kN/5 mm | 304% | 21.99 kN/2.4 mm | 148% |
XPS 100 mm*** | 38.91 kN/3 mm | 342% | 32.33 kN/3.8 mm | 286% |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Manos, G.C.; Melidis, L.; Katakalos, K.; Kotoulas, L.; Anastasiadis, A.; Chatziastrou, C. Out-of-Plane Flexure of Masonry Panels with External Thermal Insulation. Buildings 2021, 11, 335. https://doi.org/10.3390/buildings11080335
Manos GC, Melidis L, Katakalos K, Kotoulas L, Anastasiadis A, Chatziastrou C. Out-of-Plane Flexure of Masonry Panels with External Thermal Insulation. Buildings. 2021; 11(8):335. https://doi.org/10.3390/buildings11080335
Chicago/Turabian StyleManos, George C., Lazaros Melidis, Konstantinos Katakalos, Lambros Kotoulas, Anthimos Anastasiadis, and Christos Chatziastrou. 2021. "Out-of-Plane Flexure of Masonry Panels with External Thermal Insulation" Buildings 11, no. 8: 335. https://doi.org/10.3390/buildings11080335
APA StyleManos, G. C., Melidis, L., Katakalos, K., Kotoulas, L., Anastasiadis, A., & Chatziastrou, C. (2021). Out-of-Plane Flexure of Masonry Panels with External Thermal Insulation. Buildings, 11(8), 335. https://doi.org/10.3390/buildings11080335