New Trends in Biomaterials and Implants for Dentistry

A special issue of Journal of Functional Biomaterials (ISSN 2079-4983). This special issue belongs to the section "Dental Biomaterials".

Deadline for manuscript submissions: closed (31 October 2023) | Viewed by 25568

Special Issue Editor


E-Mail Website
Guest Editor
Department of Oral and Maxillofacial Surgery and Periodontology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto 14040-904, SP, Brazil
Interests: bone substitutes; guided bone regeneration; implant surface; implant surgery; collagen matrix; periodontal regeneration
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues,

Biomaterials and dental implants form part of a dental surgeon's arsenal of resources for the treatment and rehabilitation of atrophic bone ridges. The aim of this Special Issue is to present the current scenario of new trends in products, processes and techniques related to biomaterials and implants for use in dentistry. For this, we invite manuscripts that focus on a wide range of issues and concerns regarding the subject of the Special Issue, including, but not limited to, the following: bone substitutes, biologic modulators for bone and soft tissue regeneration, scaffolds, resorbable and non-resorbable membranes for guided bone and tissue regeneration, collagen matrices, implant surfaces, implant surgery, implant macrostructures and titanium mesh. In vitro, in vivo (animal) and clinical human studies will be accepted for evaluation, as well as systematic literature reviews that address the topic of this Special Issue.

Prof. Dr. Sergio Scombatti De Souza
Guest Editor

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Journal of Functional Biomaterials is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2700 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • bone substitutes
  • dental membranes
  • guided bone regeneration
  • bone graft
  • collagen matrix
  • implant surface
  • implant surgery
  • implant macrostructure
  • alveolar reconstruction

Benefits of Publishing in a Special Issue

  • Ease of navigation: Grouping papers by topic helps scholars navigate broad scope journals more efficiently.
  • Greater discoverability: Special Issues support the reach and impact of scientific research. Articles in Special Issues are more discoverable and cited more frequently.
  • Expansion of research network: Special Issues facilitate connections among authors, fostering scientific collaborations.
  • External promotion: Articles in Special Issues are often promoted through the journal's social media, increasing their visibility.
  • e-Book format: Special Issues with more than 10 articles can be published as dedicated e-books, ensuring wide and rapid dissemination.

Further information on MDPI's Special Issue polices can be found here.

Published Papers (13 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Other

13 pages, 5750 KiB  
Article
Efficacy of a Solution Containing 33% Trichloroacetic Acid and Hydrogen Peroxide in Decontaminating Machined vs. Sand-Blasted Acid-Etched Titanium Surfaces
by Giacomo Baima, Federica Romano, Ilaria Roato, Alessandro Mosca Balma, Riccardo Pedraza, Maria Giulia Faga, Federico Amoroso, Clarissa Orrico, Tullio Genova, Mario Aimetti and Federico Mussano
J. Funct. Biomater. 2024, 15(1), 21; https://doi.org/10.3390/jfb15010021 - 12 Jan 2024
Cited by 1 | Viewed by 1957
Abstract
This in vitro study assessed the efficacy of a solution containing 33% trichloroacetic acid (CCl3COOH; TCA) and hydrogen peroxide (H2O2) in decontaminating machined (MAC) and sand-blasted acid-etched (SBAE) titanium surfaces. A total of 80 titanium disks were [...] Read more.
This in vitro study assessed the efficacy of a solution containing 33% trichloroacetic acid (CCl3COOH; TCA) and hydrogen peroxide (H2O2) in decontaminating machined (MAC) and sand-blasted acid-etched (SBAE) titanium surfaces. A total of 80 titanium disks were prepared (40 MAC and 40 SBAE). Streptococcus sanguinis and Enterococcus faecalis strains were incubated on 36 samples, while the remaining 44 were kept as controls. Roughness analysis and scanning electron microscopy were used to evaluate the surface features before and after TCAH2O2 treatment. The viability of human adipose-derived mesenchymal stem cells (ASCs) after TCAH2O2 decontamination was assessed with a chemiluminescent assay along with cell morphology through fluorescent staining. TCAH2O2 preserved the surface topography of MAC and SBAE specimens. It also effectively eradicated bacteria on both types of specimens without altering the surface roughness (p > 0.05). Also, no significant differences in protein adsorption between the pristine and TCAH2O2-treated surfaces were found (p = 0.71 and p = 0.94). While ASC proliferation remained unchanged on MAC surfaces, a decrease was observed on the decontaminated SBAE specimens at 24 and 48 h (p < 0.05), with no difference at 72 h (p > 0.05). Cell morphology showed no significant changes after 72 h on both surface types even after decontamination. This study suggests TCAH2O2 as a promising decontamination agent for titanium surfaces, with potential implications for peri-implant health and treatment outcomes. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

15 pages, 33484 KiB  
Article
The Impact of Mechanical Debridement Techniques on Titanium Implant Surfaces: A Comparison of Sandblasted, Acid-Etched, and Femtosecond Laser-Treated Surfaces
by Seung-Mo Eun, Keunbada Son, Sung-Min Hwang, Young-Tak Son, Yong-Gun Kim, Jo-Young Suh, Jun Ho Hwang, Sung-Min Kwon, Jong Hoon Lee, Hyun Deok Kim, Kyu-Bok Lee and Jae-Mok Lee
J. Funct. Biomater. 2023, 14(10), 502; https://doi.org/10.3390/jfb14100502 - 9 Oct 2023
Viewed by 1951
Abstract
This study evaluated the effects of various mechanical debridement methods on the surface roughness (Ra) of dental implants, comparing femtosecond laser-treated surfaces with conventionally machined and sandblasted with large-grit sand and acid-etched (SLA) implant surfaces. The fabrication of grade 4 titanium (Ti) disks [...] Read more.
This study evaluated the effects of various mechanical debridement methods on the surface roughness (Ra) of dental implants, comparing femtosecond laser-treated surfaces with conventionally machined and sandblasted with large-grit sand and acid-etched (SLA) implant surfaces. The fabrication of grade 4 titanium (Ti) disks (10 mm in diameter and 1 mm thick) and the SLA process were carried out by a dental implant manufacturer (DENTIS; Daegu, Republic of Korea). Subsequently, disk surfaces were treated with various methods: machined, SLA, and femtosecond laser. Disks of each surface-treated group were post-treated with mechanical debridement methods: Ti curettes, ultrasonic scaler, and Ti brushes. Scanning electron microscopy, Ra, and wettability were evaluated. Statistical analysis was performed using the Kruskal–Wallis H test, with post-hoc analyses conducted using the Bonferroni correction (α = 0.05). In the control group, no significant difference in Ra was observed between the machined and SLA groups. However, femtosecond laser-treated surfaces exhibited higher Ra than SLA surfaces (p < 0.05). The application of Ti curette or brushing further accentuated the roughness of the femtosecond laser-treated surfaces, whereas scaling reduced the Ra in SLA surfaces. Femtosecond laser-treated implant surfaces, with their unique roughness and compositional attributes, are promising alternatives in dental implant surface treatments. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

21 pages, 11979 KiB  
Article
Influence of Different Porosities of Titanium Meshes on Bone Neoformation: Pre-Clinical Animal Study with Microtomographic and Histomorphometric Evaluation
by Rafael Mantovani, Ytalo Fernandes, Jonathan Meza-Mauricio, Danilo Reino, Laura Sanches Gonçalves, Luiz Gustavo Sousa, Adriana Luisa Almeida, Marcelo Faveri and Sergio Scombatti de Souza
J. Funct. Biomater. 2023, 14(10), 485; https://doi.org/10.3390/jfb14100485 - 22 Sep 2023
Viewed by 1344
Abstract
The aim of this study was to evaluate the influence of different types of porosity of titanium meshes on the bone neoformation process in critical defects surgically created in rat calvaria, by means of microtomographic and histomorphometric analyses. Defects of 5 mm in [...] Read more.
The aim of this study was to evaluate the influence of different types of porosity of titanium meshes on the bone neoformation process in critical defects surgically created in rat calvaria, by means of microtomographic and histomorphometric analyses. Defects of 5 mm in diameter were created in the calvaria of 36 rats, and the animals were randomly treated and divided into the following groups (6 animals per group): NCOG (negative control, only blood clot), TEMG (Polytetrafluoroethylene—PTFE—membrane), SPTMG (small pore titanium mesh), SPMMG (small pore mesh + PTFE), LPTMG (large pore titanium mesh), and LPMMG (large pore mesh + PTFE). After 60 days, the animals were sacrificed, and the bone tissue formed was evaluated with micro-CT and histomorphometry. The data were compared using an ANOVA followed by the Tukey post-test (p ≤ 0.05). The microtomographic results showed that the SPTMG group presented the highest numerical value for bone volume/total volume (22.24 ± 8.97), with statistically significant differences for all the other groups except LPTMG. Considering the histomorphometric evaluation, groups with only porous titanium meshes showed higher values compared to the groups that used the PTFE membrane and the negative control. The SPTMG group presented higher values in the parameters of area (0.44 mm2 ± 0.06), extension (1.19 mm2 ± 0.12), and percentage (7.56 ± 1.45%) of neoformed bone. It was concluded that titanium mesh with smaller pores showed better results and that the association of PTFE membranes with titanium meshes did not improve the outcomes, suggesting a correlation between mesh porosity and underlying bone repair. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

16 pages, 6030 KiB  
Article
Electron Microscopy (EM) Analysis of Collagen Fibers in the Peri-Implant Soft Tissues around Two Different Abutments
by Ugo Covani, Enrica Giammarinaro, Natalia Di Pietro, Simona Boncompagni, Giorgia Rastelli, Tea Romasco, Eugenio Velasco-Ortega, Alvaro Jimenez-Guerra, Giovanna Iezzi, Adriano Piattelli and Simone Marconcini
J. Funct. Biomater. 2023, 14(9), 445; https://doi.org/10.3390/jfb14090445 - 29 Aug 2023
Cited by 4 | Viewed by 1818
Abstract
The design of the implant prosthesis–abutment complex appears crucial for shaping healthy and stable peri-implant soft tissues. The aim of the present animal study was to compare two implants with different healing abutment geometries: a concave design (TEST) and a straight one (CTRL). [...] Read more.
The design of the implant prosthesis–abutment complex appears crucial for shaping healthy and stable peri-implant soft tissues. The aim of the present animal study was to compare two implants with different healing abutment geometries: a concave design (TEST) and a straight one (CTRL). Transmission electron microscopy (TEM) was used to quantify the three-dimensional topography and morphological properties of collagen at nanoscale resolution. 2 swine were included in the experiment and 6 implants per animal were randomly placed in the left or right hemimandible in either the physiologically mature bone present between the lower canine and first premolar or in the mandibular premolar area, within tooth extraction sites. Each CTRL implant was positioned across from its respective TEST implant on the other side of the jaw. After 12 weeks of healing, 8 specimens (4 CTRL and 4 TEST) were retrieved and prepared for histological and TEM analysis. The results showed a significantly higher percentage of area covered by collagen bundles and average bundle size in TEST implants, as well as a significant decrease in the number of longitudinally oriented bundles with respect to CTRL implants, which is potentially due to the larger size of TEST bundles. These data suggest that a concave transmucosal abutment design serves as a scaffold, favoring the deposition and growth of a well-organized peri-implant collagen structure over the implant platform in the early healing phase, also promoting the convergence of collagen fibers toward the abutment collar. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

17 pages, 3242 KiB  
Article
The Action of Angiocrine Molecules Sourced from Mechanotransduction-Related Endothelial Cell Partially Explain the Successful of Titanium in Osseointegration
by Patricia Fretes Wood, Célio Junior da Costa Fernandes, Gerson Santos de Almeida, Luisa Camilo Suter, João Paulo Ruiz Lucio de Lima Parra, Fábio José Bezerra and Willian Fernando Zambuzzi
J. Funct. Biomater. 2023, 14(8), 415; https://doi.org/10.3390/jfb14080415 - 8 Aug 2023
Cited by 2 | Viewed by 1414
Abstract
Since Branemark’s findings, titanium-based alloys have been widely used in implantology. However, their success in dental implants is not known when considering the heterogenicity of housing cells surrounding the peri-implant microenvironment. Additionally, they are expected to recapitulate the physiological coupling between endothelial cells [...] Read more.
Since Branemark’s findings, titanium-based alloys have been widely used in implantology. However, their success in dental implants is not known when considering the heterogenicity of housing cells surrounding the peri-implant microenvironment. Additionally, they are expected to recapitulate the physiological coupling between endothelial cells and osteoblasts during appositional bone growth during osseointegration. To investigate whether this crosstalk was happening in this context, we considered the mechanotransduction-related endothelial cell signaling underlying laminar shear stress (up to 3 days), and this angiocrine factor-enriched medium was harvested further to use exposing pre-osteoblasts (pOb) for up to 7 days in vitro. Two titanium surfaces were considered, as follows: double acid etching treatment (w_DAE) and machined surfaces (wo_DAE). These surfaces were used to conditionate the cell culture medium as recommended by ISO10993-5:2016, and this titanium-enriched medium was later used to expose ECs. First, our data showed that there is a difference between the surfaces in releasing Ti molecules to the medium, providing very dynamic surfaces, where the w_DAE was around 25% higher (4 ng/mL) in comparison to the wo_DAE (3 ng/mL). Importantly, the ECs took up some of this titanium content for up to 3 days in culture. However, when this conditioned medium was used to expose pOb for up to 7 days, considering the angiocrine factors released from ECs, the concentration of Ti was lesser than previously reported, reaching around 1 ng/mL and 2 ng/mL, respectively. Thereafter, pOb exposed to this angiocrine factor-enriched medium presented a significant difference when considering the mechanosignaling subjected to the ECs. Shear-stressed ECs showed adequate crosstalk with osteoblasts, stimulating the higher expression of the Runx2 gene and driving higher expressions of Alkaline phosphatase (ALP), bone sialoprotein (BSP), and osteocalcin. Mechanotransduction-related endothelial cell signaling as a source of angiocrine molecules also stimulated the higher expression of the Col3A1 gene in osteoblasts, which suggests it is a relevant protagonist during trabecular bone growth. In fact, we investigated ECM remodeling by first evaluating the expression of genes related to it, and our data showed a higher expression of matrix metalloproteinase (MMP) 2 and MMP9 in response to mechanosignaling-based angiocrine molecules, independent of considering w_DAE or the wo_DAE, and this profile reflected on the MMP2 and MMP9 activities evaluated via gelatin-based zymography. Complimentarily, the ECM remodeling seemed to be a very regulated mechanism in mature osteoblasts during the mineralization process once both TIMP metallopeptidase inhibitor 1 and 2 (TIMP1 and TIMP2, respectively) genes were significantly higher in response to mechanotransduction-related endothelial cell signaling as a source of angiocrine molecules. Altogether, our data show the relevance of mechanosignaling in favoring ECs’ release of bioactive factors peri-implant, which is responsible for creating an osteogenic microenvironment able to drive osteoblast differentiation and modulate ECM remodeling. Taking this into account, it seems that mechanotransduction-based angiocrine molecules explain the successful use of titanium during osseointegration. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

17 pages, 3974 KiB  
Article
A Comparative Investigation of Chemical Decontamination Methods for In-Situ Cleaning of Dental Implant Surfaces
by Badra Hussain, Sadia Khan, Anne Eriksson Agger, Jan Eirik Ellingsen, Ståle Petter Lyngstadaas, Jaime Bueno and Håvard J. Haugen
J. Funct. Biomater. 2023, 14(8), 394; https://doi.org/10.3390/jfb14080394 - 25 Jul 2023
Cited by 1 | Viewed by 1885
Abstract
Surface chemistry evaluation is crucial in assessing the efficacy of chemical decontamination products for titanium implants. This study aimed to investigate the effectiveness of chemical decontamination solutions in cleaning a contaminated dental implant surface and to evaluate the potential of combining Pluronic gel [...] Read more.
Surface chemistry evaluation is crucial in assessing the efficacy of chemical decontamination products for titanium implants. This study aimed to investigate the effectiveness of chemical decontamination solutions in cleaning a contaminated dental implant surface and to evaluate the potential of combining Pluronic gel with hydrogen peroxide (NuBone®Clean) by evaluating pellicle disruption and re-formation on implant surfaces. In addition, ensuring safety with in vitro and human testing protocols. X-ray Photoelectron Spectroscopy (XPS) was utilised for surface analysis. All the tested gels had some effect on the surface cleanness except for PrefGel®. Among the tested chemical decontamination candidates, NuBone®Clean demonstrated effectiveness in providing a cleaner titanium surface. Furthermore, none of the tested chemical agents exhibited cytotoxic effects, and the safety assessment showed no adverse events. The results of this study highlight the significance of conducting comprehensive evaluations, encompassing safety and efficacy, before introducing new chemical agents for dental treatments. The findings suggest that NuBone®Clean shows potential as a chemical decontamination solution for implant surfaces. However, further investigation through randomised clinical trials is necessary. By adhering to rigorous testing protocols, the development of safe and efficient chemical decontamination strategies can be advanced, benefiting patients and promoting progress in implant dentistry. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

19 pages, 11999 KiB  
Article
Evaluation of Implant Surface Modification with Nanohydroxyapatite Associated with the Use of L-PRF: In Vivo Study in Rats
by José Augusto Gabarra Júnior, Fernando Nóbrega, Paula Gabriela Oliveira, Edmara Tatiely Bergamo, Uislen Cadore, Milene Zezzi do Valle Gomes, Per Kjellin, Liat Chaushu, Fabio Bezerra, Bruna Ghiraldini and Sergio Scombatti de Souza
J. Funct. Biomater. 2023, 14(7), 370; https://doi.org/10.3390/jfb14070370 - 14 Jul 2023
Cited by 1 | Viewed by 1680
Abstract
Leukocyte–platelet-rich fibrin (L-PRF) contains growth factors that stimulate bone regeneration. This study evaluated the bone repair in a tibia rat model around two implant surfaces in combination or not with L-PRF by assessing microtomographic and histomorphometric parameters. A total of 48 female rats [...] Read more.
Leukocyte–platelet-rich fibrin (L-PRF) contains growth factors that stimulate bone regeneration. This study evaluated the bone repair in a tibia rat model around two implant surfaces in combination or not with L-PRF by assessing microtomographic and histomorphometric parameters. A total of 48 female rats were used in the study, in which 24 received implants with two types of surface treatments (dual acid etched—DAE or nanohydroxyapatite—nanoHA), and the other 24 received the same mini implants with L-PRF, which was collected by cardiac puncture, centrifugated, and inserted in the bone bed. The animals were euthanized 7 and 30 days after implant placement, and the retrieved samples were prepared for microtomographic and histomorphometric (bone-to-implant contact—BIC; and Bone Area Fraction Occupancy—BAFO) analyses. The adhesion of the nanoHA surface onto the implant surface was investigated by insertion and removal in simulated bone medium (Sawbones). The adhesion evaluation revealed that the loss of nanoHA after this procedure (as measured with SEM) from the implant surface was less than 1%. Overall, the nanoHA surface presented more bone in contact and in proximity to the implant, a higher bone surface/tissue volume fraction, a higher number of bone trabeculae, as well as trabecular separation relative to the DAE surface. Such results were more evident when the nanoHA surface was combined with L-PRF and after 30 days in vivo. The nanoHA surface presented higher BAFO when compared to DAE, with or without association with L-PRF. Therefore, implants with a nanoHA surface potentially benefit from the association to L-PRF. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

14 pages, 2983 KiB  
Article
Osteoblastic and Bacterial Response of Hybrid Dental Implants
by Daniel Robles, Aritza Brizuela, Manuel Fernández-Domínguez and Javier Gil
J. Funct. Biomater. 2023, 14(6), 321; https://doi.org/10.3390/jfb14060321 - 13 Jun 2023
Cited by 6 | Viewed by 1584
Abstract
Bacterial infections in dental implants generate peri-implantitis disease that causes bone loss and the mobility of the dental implant. It is well known that specific ranges of roughness favor the proliferation of bacteria, and it is for this reason that new dental implants [...] Read more.
Bacterial infections in dental implants generate peri-implantitis disease that causes bone loss and the mobility of the dental implant. It is well known that specific ranges of roughness favor the proliferation of bacteria, and it is for this reason that new dental implants called hybrids have appeared. These implants have a smooth area in the coronal part and a rough surface in the apical part. The objective of this research is the physico-chemical characterization of the surface and the osteoblastic and microbiological behavior. One-hundred and eighty discs of titanium grade 3 with three different surfaces (smooth, smooth–rough, and completely rough) were studied. The roughness was determined by white light interferometry, and the wettability and surface energy by the sessile drop technique and the application of Owens and Wendt equations. Human osteoblast SaOS-2 was cultured to determine cell adhesion, proliferation, and differentiation. Microbiological studies were performed with two common bacterial strains in oral infection, E. faecalis and S. gordonii, at different times of culture. The roughness obtained for the smooth surface was Sa = 0.23 and for the rough surface it was 1.98 μm. The contact angles were more hydrophilic for the smooth surface (61.2°) than for the rough surface (76.1°). However, the surface energy was lower for the rough surface (22.70 mJ/m2) in both its dispersive and polar components than the smooth surface (41.77 mJ/m2). Cellular activity in adhesion, proliferation, and differentiation was much higher on rough surfaces than on smooth surfaces. After 6 h of incubation, the osteoblast number in rough surfaces was more than 32% higher in relation to the smooth surface. The cell area in smooth surfaces was higher than rough surfaces. The proliferation increased and the alkaline phosphatase presented a maximum after 14 days, with the mineral content of the cells being higher in rough surfaces. In addition, the rough surfaces showed greater bacterial proliferation at the times studied and in the two strains used. Hybrid implants sacrifice the good osteoblast behavior of the coronal part of the implant in order to obstruct bacterial adhesion. The following fact should be considered by clinicians: there is a possible loss of bone fixation when preventing peri-implantitis. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

11 pages, 1878 KiB  
Article
Nanohydroxyapatite-Coated Titanium Surface Increases Vascular Endothelial Cells Distinct Signaling Responding to High Glucose Concentration
by Anderson M. Gomes, Danielle F. da Silva, Fábio J. Bezerra and Willian F. Zambuzzi
J. Funct. Biomater. 2023, 14(4), 188; https://doi.org/10.3390/jfb14040188 - 28 Mar 2023
Cited by 6 | Viewed by 1536
Abstract
Aim: The success of dental implants depends on osseointegration can be compromised by well-known related adverse biological processes, such as infection and diabetes. Previously, nanohydroxyapatite-coated titanium surfaces (nHA_DAE) have been shown to contain properties that promote osteogenesis by enhancing osteoblast differentiation. In addition, [...] Read more.
Aim: The success of dental implants depends on osseointegration can be compromised by well-known related adverse biological processes, such as infection and diabetes. Previously, nanohydroxyapatite-coated titanium surfaces (nHA_DAE) have been shown to contain properties that promote osteogenesis by enhancing osteoblast differentiation. In addition, it was hypothesized to drive angiogenesis in high-glucose microenvironments, mimicking diabetes mellitus (DM). On the other hand, the null hypothesis would be confirmed if no effect was observed in endothelial cells (ECs). Materials and methods: Titanium discs presenting the differential surfaces were previously incubated in an FBS-free cell culture medium for up to 24 h, which was, thereafter, supplemented with 30.5 mM of glucose to expose human umbilical vein endothelial cells (HUVECs, ECs) for 72 h. They were then harvested, and the sample was processed to provide molecular activity of specific genes related to EC survival and activity by using qPCR, and the conditioned medium by ECs was used to evaluate the activity of matrix metalloproteinases (MMPs). Results: Our data guaranteed better performance of this nanotechnology-involved titanium surface to this end once the adhesion and survival characteristics were ameliorated by promoting a higher involvement of β1-Integrin (~1.5-fold changes), Focal Adhesion Kinases (FAK; ~1.5-fold changes) and SRC (~2-fold changes) genes. This signaling pathway culminated with the cofilin involvement (~1.5-fold changes), which guaranteed cytoskeleton rearrangement. Furthermore, nHA_DAE triggered signaling that was able to drive the proliferation of endothelial cells once the cyclin-dependent kinase gene was higher in response to it, while the P15 gene was significantly down-regulated with an impact on the statement of angiogenesis. Conclusions: Altogether, our data show that a nanohydroxyapatite-coated titanium surface ameliorates the EC performance in a high-glucose model in vitro, suggesting its potential application in DM patients. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

12 pages, 276 KiB  
Article
The Effect of Anticoagulants on Early Implant Failure: A Retrospective Cohort Study
by Liat Chaushu, Noa Perez, Daniele Botticelli, Samuel Porfirio Xavier, Roni Kolerman and Daya Masri
J. Funct. Biomater. 2023, 14(4), 186; https://doi.org/10.3390/jfb14040186 - 27 Mar 2023
Cited by 3 | Viewed by 1976
Abstract
Background: Anticoagulants (AC) are among the most often prescribed drugs in the world. Data regarding ACs’ effect on the osseointegration of dental implants is lacking. Purpose: The aim of the present retrospective cohort study was to evaluate the effect of anticoagulants (AC) on [...] Read more.
Background: Anticoagulants (AC) are among the most often prescribed drugs in the world. Data regarding ACs’ effect on the osseointegration of dental implants is lacking. Purpose: The aim of the present retrospective cohort study was to evaluate the effect of anticoagulants (AC) on early implant failure (EIF). The null hypothesis was that the use of AC increases the incidence of EIF. Materials and Methods: The research included 687 patients who underwent 2971 dental implant placements in the department of oral and maxillofacial surgery in Rabin medical center, Beilinson hospital, by specialists in oral and maxillofacial surgery. The study group comprised 173 (25.2%) patients and 708 (23.8%) implants using AC. The rest of the cohort served as a control. A structured form was used to collect data at patient and implant level. EIF was defined as implant failure within a period of up to 12 months from loading. EIF was the primary outcome parameter. A logistic regression model was used to predict EIF. Results: Implants placed in individuals ≥ 80 (odds ratio (OR) = 0.34, p = 0.05), and ASA 2/3 vs. ASA 1 individuals (OR = 0.30, p = 0.02/OR = 0.33, p = 0.03, respectively) had decreased odds of EIF, and implants in those using anticoagulants (OR = 2.64, p = 0.01) had increased odds of EIF. At the patient level, the odds of EIF in ASA 3 (OR = 0.53, p = 0.02) and IHD (OR = 0.40, p = 0.02) individuals decreased. In AF/VF (OR = 2.95, p = 0.01) individuals, EIF odds increased. Conclusions: Within the limitations of the present study, the use of AC is significantly associated with an increased likelihood of EIF: the OR was 2.64. Future research is required to validate and examine the prospective impact of AC on the osseointegration phenomena. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
14 pages, 3309 KiB  
Article
Epigenetic Differences Arise in Endothelial Cells Responding to Cobalt–Chromium
by Célio Junior da C. Fernandes, Rodrigo A. Foganholi da Silva, Gerson Santos de Almeida, Marcel Rodrigues Ferreira, Paula Bertin de Morais, Fábio Bezerra and Willian F. Zambuzzi
J. Funct. Biomater. 2023, 14(3), 127; https://doi.org/10.3390/jfb14030127 - 26 Feb 2023
Viewed by 1624
Abstract
Cobalt–chromium (Co-Cr)-based alloys are emerging with important characteristics for use in dentistry, but the knowledge of epigenetic mechanisms in endothelial cells has barely been achieved. In order to address this issue, we have prepared a previously Co-Cr-enriched medium to further treat endothelial cells [...] Read more.
Cobalt–chromium (Co-Cr)-based alloys are emerging with important characteristics for use in dentistry, but the knowledge of epigenetic mechanisms in endothelial cells has barely been achieved. In order to address this issue, we have prepared a previously Co-Cr-enriched medium to further treat endothelial cells (HUVEC) for up to 72 h. Our data show there is important involvement with epigenetic machinery. Based on the data, it is believed that methylation balance in response to Co-Cr is finely modulated by DNMTs (DNA methyltransferases) and TETs (Tet methylcytosine dioxygenases), especially DNMT3B and both TET1 and TET2. Additionally, histone compaction HDAC6 (histone deacetylase 6) seems to develop a significant effect in endothelial cells. The requirement of SIRT1 seems to have a crucial role in this scenario. SIRT1 is associated with a capacity to modulate the expression of HIF-1α in response to hypoxia microenvironments, thus presenting a protective effect. As mentioned previously, cobalt is able to prevent HIF1A degradation and maintain hypoxia-related signaling in eukaryotic cells. Together, our results show, for the first time, a descriptive study reporting the relevance of epigenetic machinery in endothelial cells responding to cobalt–chromium, and it opens new perspectives to better understand their repercussions as prerequisites for driving cell adhesion, cell cycle progression, and angiogenesis surrounding this Co-Cr-based implantable device. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

13 pages, 11839 KiB  
Article
Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
by Yu-Hsuan Chen, Yu-Ling Wu, Hung-Shyong Chen, Ching-Ping Lin and Aaron Yu-Jen Wu
J. Funct. Biomater. 2023, 14(3), 124; https://doi.org/10.3390/jfb14030124 - 24 Feb 2023
Cited by 1 | Viewed by 2462
Abstract
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two [...] Read more.
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

Other

Jump to: Research

27 pages, 1270 KiB  
Systematic Review
Surface Functionalization of Titanium-Based Implants with a Nanohydroxyapatite Layer and Its Impact on Osteoblasts: A Systematic Review
by Karolina Homa, Wojciech Zakrzewski, Wojciech Dobrzyński, Paweł J. Piszko, Aleksandra Piszko, Jacek Matys, Rafal J. Wiglusz and Maciej Dobrzyński
J. Funct. Biomater. 2024, 15(2), 45; https://doi.org/10.3390/jfb15020045 - 16 Feb 2024
Cited by 13 | Viewed by 3091
Abstract
This study aims to evaluate the influence of a nanohydroxyapatite layer applied to the surface of titanium or titanium alloy implants on the intricate process of osseointegration and its effect on osteoblast cell lines, compared to uncoated implants. Additionally, the investigation scrutinizes various [...] Read more.
This study aims to evaluate the influence of a nanohydroxyapatite layer applied to the surface of titanium or titanium alloy implants on the intricate process of osseointegration and its effect on osteoblast cell lines, compared to uncoated implants. Additionally, the investigation scrutinizes various modifications of the coating and their consequential effects on bone and cell line biocompatibility. On the specific date of November 2023, an exhaustive electronic search was conducted in esteemed databases such as PubMed, Web of Science, and Scopus, utilizing the meticulously chosen keywords ((titanium) AND ((osteoblasts) and hydroxyapatite)). Methodologically, the systematic review meticulously adhered to the PRISMA protocol. Initially, a total of 1739 studies underwent scrutiny, with the elimination of 741 duplicate records. A further 972 articles were excluded on account of their incongruence with the predefined subjects. The ultimate compilation embraced 26 studies, with a predominant focus on the effects of nanohydroxyapatite coating in isolation. However, a subset of nine papers delved into the nuanced realm of its modifiers, encompassing materials such as chitosan, collagen, silver particles, or gelatine. Across many of the selected studies, the application of nanohydroxyapatite coating exhibited a proclivity to enhance the osseointegration process. The modifications thereof showcased a positive influence on cell lines, manifesting in increased cellular spread or the attenuation of bacterial activity. In clinical applications, this augmentation potentially translates into heightened implant stability, thereby amplifying the overall procedural success rate. This, in turn, renders nanohydroxyapatite-coated implants a viable and potentially advantageous option in clinical scenarios where non-modified implants may not suffice. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

Back to TopTop